HomeMy WebLinkAboutEngineer PlanLEGEND X 99. / EXIST. SPOT ELEV. -[99]- PROPOSED CONTOUR [98.4] PROPOSED SPOT EL. TH1 TEST HOLE SLOPE OF GROUND UTILITY POLE Y FIRE HYDRANT NOTE' NOT ALL SYMBOLS MAY APPEAR IN DRAM14G EL.= 29.5' 20.43' =*21.9'± ZABEL FILTER (Al00) OUTLET TEE W/EXTENSION \ I ALARM LIGHT ALARM AND CONTROL PANEL ACCESS FOR ROUTINE MAINTENANCE SYSTEM PROFILE TO BE INSTALLED INSIDE MUST BE PROVIDED FOR ZABEL FILTER. BUILDING. ALARM To BE ON INSTALLER MUST FOLLOW ALL (NOT TO SCALE) SEPARATE CIRCUIT FROM PUMP MANUFACTURER'S SPECIFICATIONS FOR ALL WIRING TO CODE. PROPER FILTER INSTALLATION 20P. WATERTIGHT COVERS TO GRADE PROVIDE QUICK DISCONNECT FOR PUMP FILTER PEAS LTER FABRIC OVER STONE OR GEOTEXT FI PRECAST TO GRADE 23.0' ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE VENT W/ CHARCOAL FILTER 0 2% SLOPE REQUIRED OVER SYSTEM 29.0' PRECAST H-10 2" PRESSURE LINE RISERS (TYP.) SLOPE TO DRAIN BACK 40 PVC BLOCKS OR z' a 20 68, FLOAT SWITCH k LEVEL 1ST 2 MORTAR ALL PRECAST RISERS SETTINGS: 4' COMPONENTS ALARM ON �ENDS (TMP') SIDES rE.1 PUMP ON ®�� ®®®® ° °- -�®®° o °o o0 0 0 o 0 o og®®®®®®®® o°oao�o�5" WORKING RANGE 24.27 0 °°°°°°o c, °° o °o pp�� ; o o ° o> 0 0 0 0®®®®tea® °o°o°oaC®®�®®®. o 0 0 0®®®� ® ®oaa o00000®tea®La®®® ;�o-aoo°o, 5" >o°°o°°p°°p0 °°°O o c o 0 o n 12" PUMP OFF fi H-20 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. WEEP HOLES 6" CRUSHED STONE OR MECHANICAL 3/4"-1-1/2" DOUBLE WASHED STONE (2) UNITS REQUIRED CHECK VALVE COMPACTION. (15.221 [2]) OVERALL DIMENSIONS TO OUTSIDE OF STONE: 30' X 9.83' 6" BAFFLE MYERS SRM 4 ° 6" CRUSHED STONE OR MECHANICAL SUBMERSIBLE 4/10 HP PUMP COMPACTION. (15.221 [2]) SYSTEM (OR EQUAL) (�% SLOPE) (ON BLOCK) (1 % SLOPE) H-10 17.0' BOTTOM TH-1 FOUNDATION 17' SEPTIC TANK 33' D'BOX 12' LEACHING FACILITY NO GROUNDWATER FOUND *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM " BENCHMARK: _ CONC. BOUND �- - =30.3' NAVD88 -----PROP-. VENT -� AND BUGSQI 0 MAP 137 PARC4 0 JOCELN DYETT B ND0 DOC 1274 0 N S0, TC6 ?4 2 .01 (SHED Ij i10 J ,22 0 err 17 7g qM tiF ^° 9 qF AE OO • • • • • • • • • • • • • . • . • • • • • . • LOT 2 12,155f \ /. PROP. ZND STORY ON (WITHIN EX. -FOOTPRINT) •DWELLINGEXISTING ` N `�,' `TOF = 29.5 EX. DECK 21 THE YARMOUTH BOARD OF HEALTH SHALL REQUIRE THE FOLLOWING INSPECTIONS: 1. ENGINEER TO STAKE IN THE FIELD SAS PRIOR TO EXCAVATION. 2. INSPECTION OF UNSUITABLE MATERIAL (IF ANY). 3. VERIFICATION OF CESSPOOL/LEACH PIT REMOVAL OR ABANDONMENT. 4. INSPECTION OF FLOW BARRIER INSTALLATION. 5. INSPECTION OF THE 3/4 - 1 1/2 INCH STONE PRIOR TO PLACEMENT. 6. FINAL INSPECTION OF ALL COMPONENTS PRIOR TO BACKFILLING. 7. FINAL GRADING INSPECTION. J \. 35 cJ � I N k c \ D OtiF .01 G \ F 00, 2 \ 11 R� 2� yF 0 20 L j 15 w Z 0 C 10 w J 0 ~ 5 0 25 50 75 100 CAPACITY - GPM PUMP CURVE FOR MYERS SRM4 4/10 HP PUMP LIVING ROOM DOWN I KITCHEN DEN BATH BEDROOM �I FIRST FLOOR PLAN (N.T.S.) n�rl� bLI,UINU r LUUN I'U-1IN (N.T.S.) 0' o' 40 MIL LINER Yarmouth Conservation Conditions: 1. A hard copy of the plan shall be provided to the Conservation Administrator for review. An electronic copy of the final plan shall be provided to kgrant@yarmouth.ma.us. 2. The proposed sewage disposal system shall meet the applicable Title 5 wetlands setbacks as set forth by the Health Department. 3. A "work limit" line shall be established with Erosion Controls (i.e straw bales, staked filter fabric, bark mulch, "silt sacks," products made with rice straw, and other weed -free products or approved by the Commission.) Hay bales are not allowed. it is the applicant's responsibility to implement and maintain appropriate and adequate erosion controls measures throughout the construction process. 4. No work of any kind shall occur on the Resource Area side of the work limit line. This line shall be established prior to any construction or work. 5. All imported fill shall be clean and not contain any foreign debris such as cement, bituminous concrete, rubber. metal, trash, boulders, etc. 6. Debris, including litter, shall be picked up immediately. Any excess material that is excavated from the job site shall be disposed of at a location approved by the Conservation Administrator or in a covered dumpster. No debris shall be allowed in a Wetland or Waterway. 7. Washing of equipment/tools shall be done OFF -SITE or handled in a manner approved by the Conservation Administrator. 8. No equipment shall be refueled, nor shall fuel be stored within 100 feet of a resource area. 9. The cesspool is to be pumped dry, the connection broken, and filled with clean sand. 10. Any area that is disturbed during construction shall be revegetated immediately or as soon after as the growing season commences. Permanent stabilization shall be carried out in order to minimize erosion. NOTES 1. DATUM IS RLV 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1 /8" PER FOOT. 4. DESIGN LOAD114G FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-M (H-20 LEACHING) 5. PIPE JOINTS '1_0 BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOP LOT LINE STAKING OR ANY OTHER PURPOSE. ' 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. SEE PROPOSED BUILDING PLANS FOR FLOOR PLAN. 14. INSTALLER ', 0 CONFIRM SUITABILITY OF ELECTRICAL SYSTEM FOR PUMP INSTALLATION. ELECTRICAL PERMIT REQUIRED, VARIANCES REQUESTED: LNDER MAX. FEASIBLE COMPLIANCE 15.405: (1a): REDUCTION IN SETBACK, SAS TO LOT LINE (10' TO 3.4') (1b): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 10.0') (1b): SAS TO BE > 3' BUT < 6' BELOW FINISH GRADE (VENT AND H-20 PROVIDED) (1g): REDUCTION IN SETBACK, SAS TO DRAIN WHICH DISCHARGES TO SURFACE WATER SUPPLY '1100' TO 650) UNDER TOWN OF YARMOU IH HEALTH REGULATIONS: (3.7): REDUCTION IN SETBACK, SEPTIC TANK TO BVW (50' TO 86') TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE. #13871 WITNESS: PHIL RENAUD DATE: 6/30/21 _ PERC. RATE _ __< 2 MIN/INCH CLASS SOILS ELEV. 0» 23.0' A LS 1OYR 3/2 18" - B LS 42„ 10YR 5/8 24.5' C PERC MS 2.5Y 7/4 132" 1 ` 17.0' NO GROUNDWATER ENCOUNTERED o ° West ath nc on Id Ch Q� Road �a. �n Cb c`� q �c o• Locu K„ F011ins o Pond.: a Orift /r ' T or s Od S '" fh o� Kelley'S, Bay Cb p a. LOCUS MAP SCALE 1 "=2000'f ASSESSORS MAP 137 PARCEL 9 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) & ZONE AE (EL. 9) AS SHOWN ON COMMUNITY PANEL #25001 CO583J DATED 7/16/2014 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS 0 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 2500 GAL. SEPTIC TANK P.C. COMBO LEACHING: SIDES: 2(30 + 9.83) 2 (.74) = 118 GPD BOTTOM 3G x 9.83 J7 = 218 GPD TOTAL: 454 S.F. 336 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 2.5' STONE AT SIDES, 4' AT ENDS AND 5' BETWEEN UNITS ZONING SUMMARY ZONING DISTRICT: R-40 DISTRICT REQUIRED: EXISTING: PROPOSED: MIN. LOT SIZE 40,000 S.F. 12,155 S.F.f 12,155 S.F.t MIN. LOT FRONTAGE 150' 213.42' 213.42' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 20' MIN. REAR SETBACK 20' MAX. BUILDING COVERAGE 25% Permit val f g REPAIR OF 49rqjc SVSTEM ONLY, du25o23tate and Loca2544ic variances. Board of Hs".Veview and appr6.31a'required for any futu 9u0(litions/renovati9ng> .kerations to sewage faci �69 and/or structures/welling. Yarmouth Health Department APPROVED • 0�d1" Date 27 LONGVIEW RD. H 0F MgsS90y tH OF MgSs DAANIEL G���`' DANIELA. ,n YARMOUTH PORT,-- MA a OJALA OJAf.A CIVIL U, PREPARED FOR o No"40980P No. 46502 o toP �� O 4, `9NOSUR�ENAL E s,rSTE�C � ROBERT KOSSACK O DATE: AUGUST 26, 2021 REV.: SEPTEMBER 10, 2021 (BOH NOTES) uOFFq OF fvJ SS�� f;��Lt, tiSs Scale: l' = 20' 45 DA:!E'_A, �i1L5v 5 DANIEI- Gs z E t I_A MAR�Z3<+� 0 10 20 30 40 50 FEET �0 o o QaF J�o� STEM G\�c�yl- off 508-362-4541 1.1MTH DEPT. \� � Ess� �o//s was *;aL�% fax 508-362-9$80 downcape.com y°rJ a down cape engineering, Inc. civil engineers land surveyors DATE DANIEL A. OJALA, P.E., P.L.S. 939 Main Street ( Rte 6A) YARMOU THPOR T MA 02675 16-288 KOSSACK.DWG DCE # > 6--288 EA W