Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD-23-002846
ONE &TWO FAMILY ONLY- BUILDING PERMIT Town of Yarmouth Building Department oF.....y •._ 1146 Route 28,South Yarmouth,MA 02664-4492 508-398-2231 ext. 1261 Fax 508-398-0836 ■ `s Massachusetts State Building Code,780 CMR Building Permit Application To Construct,Repair, Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: -Aa, (-16 Date A plied: Buildin fficial(Pri ame) i .afore SECTI 1:SITE INFORMATION RECEIVED L1 Property Address: 1.2 Assessors Map&Parcel Numbers 40 WREN WAY 88 47 • NOV 2 2 2022 1.1a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: BUILDING DEPARTMENT ay _ Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public Private❑ Zone: _ Outside Flood;one? Municipal M"On site disposal system 0 Check if yes SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: ERIC LAVOIE Yarmouth MA, 02664 Name(Print) City,State,ZIP 40 WREN WAY 508-580-6920 thacherlazzari@yahoo.com No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction 0 Existing Building 0 Owner-Occupied ❑ Repairs(s) 0 Alteration(s) 0 Addition 0 Demolition 0 Accessory Bldg.0 Number of Units Other 0 Specify: Brief Description of Proposed Work2: Installation of an interconnected PV system including 27 panels at 8.585 Kw DC NO ESS SECTION 4:ESTIMATED CONSTRUCTION COSTS. Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building $ 5607.00 1. Building Permit Fee:$ _Indicate how fee is determined: ❑Standard City/Town Application Fee 2.Electrical S 13082.00 ❑Total Project Cost3(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: W901166,253, 5.Mechanical (Fire Suppression) Total All Fees:$ Check No. Check Amount: Cash Amount: 6.Total Project Cost: $ 18689.00 ❑Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-040622 08/01/2023 Stephen Kelly License Number Expiration Date Name of CSL Holder List CSL Type(see below) U 16 Parkway Rd No.and Street Type Description Stoneham MA, 02180 U Unrestricted(Buildings up to 35,000 cu.ft.)_ R Restricted I&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 978 793-7881 eastmapermits@sunrun.com I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 180120 10/13/2024 Sunrun Installation Services Inc./Stephen Kelly HIC Registration Number Expiration Date . HIC Company Name or HIC Registrant Name 695 Myles Standish Blvd. eastmapermits@sunrun.com No.and Street Email address Taunton_MA 02780 978 793-7881 City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes Sifi No ❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Sunrun Installation Services Inc./Stephen Kelly to act on my behalf,in all matters relative to work authorized by this building permit application. See Attached Contract 11/21/2022 Print Owner's Name(Electronic Signature) Date • SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. a 11/21/2022 Print Owner's or Aut orize gent's Name(Electro c Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.aov/oca Information on the Construction Supervisor License can be found at www.mass.aov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" ,�-.....,41 SUNRINC-02 LWANG2 ACORO CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDD/YYYY) `.../ 8/31/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER License#DC36861 CONTACT Walter Tanner NAME: Alliant Insurance Services,Inc. PHONE I FAX rc 560 Mission St 6th Fl (A ,No,Ext): (NC,No): San Francisco,CA 94105 ID A 5s:Walter.Tanner@alliant.com INSURERS)AFFORDING COVERAGE NAIC# INSURER A:Evanston Insurance Company 35378 INSURED INSURER B:James River Insurance Company 12203 Sunrun Installation Services,Inc INSURER C:American Zurich Insurance Company 40142 775 Fiero Lane,Suite 200 Ph#805-540-7643 INSURERD: San Luis Obispo,CA 93401 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXP UMITS LTR INSD WVD (MM/DD/YYYY) (MM/DD/YYYYI A X COMMERCIAL GENERAL LIABIUTY EACH OCCURRENCE $ 2,000,000 CLAIMS-MADE X' OCCUR MKLV5ENV103749 10/1/2022 1a1n023 DAMAGETORENTED 1,000,000 PREMISES(Ea acwnencel $ MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 X POLICY X JECT LOC PRODUCTS-COMP/OP AGG $ 2,000,000 X OTHER:Retention:$100,000 Per Project Agg $ 5,000,000 AUTOMOBILE LIABILI--Y -(Ea ac i COMBINED LIMIT) $ ANY AUTO _._ 'BODILY INJURY(Per person) $ OWNED ' SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ AUTEOSp AUU ONLY .— TOS ONLYY (Per ec,deentt AGE $ $ B UMBRELLA LIAB X OCCUR 1 EACH OCCURRENCE $ 4,000,000 X EXCESS LIAB CLAIMS-MADE '001072261 10/1/2021 10/1/2022 AGGREGATE $ 4,000,000 DED I RETENTION$ $ C WORKERS COMPENSATION X PER OTH- AND EMPLOYERS'LIABILITY Y/N STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE � I WC614287601 1 DI1I2022 1a1n023 E L EACH ACCIDENT $ 1,000,000 QFFICER/MRMBER EXCLUDED? N NIA 1,000,000 ( endatory m NXX�I E.L.DISEASE-EA EMPLOYEE $ If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ r DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES (ACORD 101.Additional Remarks Schedule.may be attached if more space is required) Workers'Compensation Policy WC614287601 Deductible:$1,000,000. Re:Permitting within jurisdiction. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of Yarmouth THE EXPIRATION DATE THEREOF. NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. 1146 Route 28 South Yarmouth.MA 02664-4492 AUTHORIZED REPRESENTATIVE ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations Lafayette City Center 2 Avenue de Lafayette, Boston,MA 02111-1750 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Sunrun Installation Services /Stephen Kelly Address:225 Bush St STE 1400 City/State/Zip: San Francisco CA 94104 Phone#: 978 793-7881 Are you an employer? Check the appropriate box: Type of project(required): l.® I am a employer with 50 4. ❑ I am a general contractor and I 6. New construction employees(full and/or part-time).* have hired the sub-contractors 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑Remodeling ship and have no employees These sub-contractors have 8. ❑Demolition workingfor me in anycapacity. employees and have workers' p tY 9. ❑Building addition [No workers' comp. insurance comp.insurance.* required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.]t c. 152, §1(4),and we have no employees. [No workers' 13.®Other Roof Mounted Solar comp. insurance required.] *My applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. *Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: American Zurich Insurance Company Policy#or Self-ins. Lic. #:WC614287601 Expiration Date: 10/01/2023 Job Site Address: 40 WREN WAY City/State/Zip: Yarmouth MA 02664 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury that the information provided above is true and correct. Signature: Date: 11/21/2022 Phone#: 978-793-7881 Official use only. Do not,trite in this area,to be completed by city or town official. City or Town:_ Permit/License# Issuing Authority(check one): 10Board of Health 2❑Building Department 31:City/Town Clerk 4.1:1 Electrical Inspector 51:1Plumbing Inspector 6.0Other Contact Person: Phone#: Commonweanh of Massachusetts Construction Supervisor Division of Professional Ucenwre i 110 Ui h ted -Buildings of any use group which contain Board of Building Rqgut ations and Standards ( less than 16,000 cubic feet dial cubic meters)of enclosed Constra,ct jl open.,,, sPiPte CS-040622 * ? Ejtyires 08/01/023 STEPHEN A(WILY . 16 PARKWAY ROAD STONEHAM t 02160 { ijeu itikfiti ,,1 Failure to possess a current edition of the Massachusetts mmissioner deti n j f{ State Building Code is cruse for revocation of this tioesss. Ct For information about this license Cap(617)727-3200 or visit wvwmass.govfdp1 THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs and Business Regulation 1000 Washington 5)rE1et-Suite 710 Boston,Massachusetts 02118 Home Improvement Contractor Registration 1 _ Type: Supplement Card SUNRUN INSTALLATION SERVICES INC. -� Regiahatlon: 180120 21 WORLDS FAIR DR ,. EapNdon 10/13/2024 SOMERSET NJ 08873 Update Address end Ream Card. THE COMMONWEALTH OF MASSACHUSETTS Ofllos of Cauwtw AReva&Busies.Regulation RegstraMn void tot tltdleidt.al use only belay due N01t II/MOVEMENT CONTRACTOR expiration dale.R found return to, Type:Suiiplemeni Gerd Otlira o1 Consumer Affairs and&avo s Reputation EIMESEMIERS 0 1000 WesNngton Street-SWs 710 1e0120 10/13/2024 80s10n.MA 0211a SUNRUN INSTALLATION SERVICES INCSTEPH . BUSH S KELLY 796 *A E tat STREET yEwAa io INIFRANCASCO.CA ilHN 1Mdsrian y void wIthou2;lignature Stephen A Kelly 695 Myles Standish Blvd Taunton MA 02780 TEL:978-793-7881 Email: eastmapermits@sunrun.com §TOWN OF YARMOUTH 1146 Route 28, South Yarmouth, MA 02664 508-398-2231 ext. 1261 Fax 508-398-0836 Office of the Building Commissioner BUILDING DEPARTMENT DEMOLITION DEBRIS DISPOSAL AFFIDAVIT Pursuant to M.G.L. Ch. 40, §54 and 780 CMR- Section 105.3.1. #4. I hereby certify that the debris resulting from the proposed work/demolition to be conducted at 40 WREN WAY, Yarmouth MA, 02664 Work Address Is to be disposed of oat the following location: 695 Myles Standish Blvd. Taunton, MA 02780 Said disposal site shall be a licensed solid waste facility as defined by M.G.L. Ch. 111, §150A. 11/21/2022 Signature f Application Date Permit No. ONE or TWO FAMILY— BULDING PERMIT APPLICATION REGULATORY APPROVALS NOTICE Address of Proposed Work: 40 WREN WAY Scope of Proposed Work: Installation of an interconnected PV system including 27 panels at 9.585 Kw DC Date: 11/21/2022 Based on the scope of work described above,the applicant is required to obtain approval sign- offs from the following departments as checked-of below: Health Dept.—508-398-2231 ext. 1241 Conservation—508-398-2231 ext. 1288 Water Dept. —99 Buck Island Road, 508-771-7921 Old Kings HWY. Hist. Comm. —508-398-22631 ext. 1292 Engineering Dept.—508-398-2231 ext. 1250 Fire Dept.—Kevin Huck/Scott Smith, 96 Old Main Street,SY Note: Please call Fire Department for an appointment. 508-398-2212 Other Appropriate plans and/or application shall be provided to each departments checked-off above. Each of these regulatory authorities has their own requirements outside the jurisdiction of the Building Department. All applicable approvals shall be obtained prior to submitting a building permit application to the Building Dept. Thank you for your cooperation. Receipt Acknowledgement: a 11/21/2022 Applicant's Signature Date Rev.Jan. 2019 Sunrun BrightAdvantageTM Agreement Eric Lavoie 40 Wren Way, Yarmouth, MA, 02664 Take Control of Your Electric Bill $0 $43 , 132 . 50 $0 .212 Amount Due at Amount Due Implied cost per kWh Signing at Installation OWN YOUR SYSTEM AND YOUR SAVINGS Buy your Solar System - it's You may be eligible for a We also provide a yours on day 1! We handle Federal Solar Tax Credit, worry-free, 10-year project management, consult your tax advisor roof warranty. permitting, design, & installation. A SOLAR SYSTEM DESIGN FOR YOUR HOME You get a 9.59 kW DC Solar System With 27 Solar Panels and 1 Inverter(s) Which will produce an est. 8,615 kWh in its first year And offset approx. 100% of your current estimated, electricity usage YOUR S REPRESENTA Rick D rick.denton sunrur (774)836 • • R . . By signing below, you acknowledge that you have reviewed and received a complete copy of the Agreement without any blanks. Such Agreement shall be the complete understanding between the Parties. SUNRUN INSTALLATION SERVICES INC. Signature: Print Name: Date: Title: Federal Employer Identification Number: 77-0471407 IF YOU CHOOSE TO PAY BY CHECK, MAKE CHECKS OUT TO SUNRUN INSTALLATION SERVICES INC. NEVER MAKE A CHECK OUT TO A SALES REPRESENTATIVE. OUR SALES REPRESENTATIVES ARE NOT AUTHORIZED TO RECEIVE CHECKS IN THEIR OWN NAMES. YOU, THE BUYER, MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF THE TENTH BUSINESS DAY AFTER THE EFFECTIVE DATE. PLEASE REVIEW THE ATTACHED NOTICES OF CANCELLATION FOR AN EXPLANATION OF THIS RIGHT. DO NOT SIGN THIS AGREEMENT IF THERE ARE ANY BLANK SPACES. Customer Primary Account Holder Secondary Account Holder (Optional) r—DocuSigned by: '" iRgfufd . Eric Lavoie Signature 11/17/2022 Date Print Name Email Address*: lavoieer@yahoo.com Mailing Address (if different than home address): 40 Wren Way Yarmouth, MA 02664 Phone: (508) 776-0196 Email addresses will be used by Sunrun for official correspondence, such as sending invoices. Sales Consultant Qlld9be/ow/acknowledge that/am Sunrun accredited, that I presented this agreement according to t D Code of Conduct, and that/obtained your homeowner's signature on this agreement. signature Rick Denton Print Name 1465508579 Sunrun ID number • EV projects@evengineersnet.com 276-220-0064 mom ENGINEERS http://www.evengineersnet.com 11/21/2022 RE:Structural Certification for Installation of Residential Solar ERIC LAVOIE:40 WREN WAY,YARMOUTH,MA,02664 Attn:To Whom It May Concern This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report,the roof is made of Composite shingle roofing over roof plywood supported by 2X6 Rafters at 16 inches.The slope of the roof was approximated to be 23 degrees. After review of the field observation data and based on our structural capacity calculation,the existing roof framing has been determined to be adequate to support the imposed loads without structural upgrades. Contractor shall verify that existing framing is consistent with the described above before install.Should they find any discrepancies,a written approval from SEOR is mandatory before proceeding with install.Capacity calculations were done in accordance with applicable building codes. Design Criteria Code 2015 IRC(ASCE 7-10)-CMR 780 9th Ed Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 140 mph PV Dead Load DPV 3 psf Exposure C Roof Live Load Lr 20 psf Ground Snow S 30 psf If you have any questions on the above, please do not hesitate to call. STRUCT ; '. ONL `NOFMq Sincerely, y�E9 Ss9� O� S �4 VINCENT Vincent Mwumvaneza, P.E. 0 MWUMVANEZA EV Engineering, LLC N'CIVIL 2 proiects@evengineersnet.com :./ Este http://www.evengineersnet.com .� ONAIENG 1/1 =- EV projects@evengineersnet.com 276-220-0064 mom ENGINEERS http://www.evengineersnet.corn Structural Letter for PV Installation 11/21/2022 Job Address: 40 WREN WAY YARMOUTH, MA,02664 Job Name: ERIC LAVOIE Job Number: 112122 EL Scope of Work This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing.All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Table of Content Sheet 1 Cover 2 Attachment checks 3 Snow and Roof Framing Check 4 Seismic Check and Scope of work Engineering Calculations Summary Code 2015 IRC(ASCE 7-10)-CMR 780 9th Ed Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 30 psf Wind Load (component and Cladding) V � h' mph Exposure C References NDS for Wood Construction STRUCT . ONL �y,�AvSHOFMMSS4 Sincerely, �� VINCENT MWUMVANEZA CIVIL Vincent Mwumvaneza,P.E. Ni") E9 �e EV Engineering, LLC �y�-'•/ -N�`� projects a(�evengineersnet.com oNaIE http://www.evengineersnet.com 1/1 • ' EV projects@evengineersnet.com 276-220-0064 v ENGINEERS http://www.evengineersnet.com Wind Load Cont. Risk Category= II ASCE 7-10 Table 1.5-1 Wind Speed(3s gust),V= Imph ASCE 7-10 Figure 26.5-1A Roughness= C ASCE 7-10 Sec 26.7.2 Exposure= #" r ASCE 7-10 Sec 26.7.3 Topographic Factor,KZT= 1.00 ASCE 7-10 Sec 26.8.2 Pitch= 23.0.Degrees Adjustment Factor,A= 1.35 ASCE 7-10 Figure 30.5-1 a= 2.20 ft ASCE 7-10 Figure 30.5-1 Where a:10%of least horizontal dimension or 0.4h,whichever is smaller,but not less than 4%of least horizontal dimension or 3ft(0.9m) Uplift(0.6W1 Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= -29.3 -41.3 -65.1 Figure 30.5-1 Pnet=0.6 x X x KZT x Pnet30)= 23.75 33.46 52.75 Equation 30.5-1 Downpressure(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= 15.7 15.7 15.7 Figure 30.5-1 Pnet=0.6 x X x KZT x Pnet30)= 12.73 12.73 12.73 Equation 30.5-1 Rafter Attachments:0.6D+0.6W(CD=1.6) Connection Check Attachement max.spacing= $. n`ft 205 lbs/in Lag Screw Penetration 2.5 in Allowable Capacity= 512.5 0.6D+0.6W Dpv+0.6W Zone Trib Width Area(ft) Uplift(Ibs) Down(lbs) 1 5.3 11.4 250.1 179.2 2 5.3 11.4 360.7 179.2 3 2 4.7 241.0 74.4 Max= 360.7 < 512.5 CONNECTION IS OK 1. Pv seismic dead weight is negligible to result in significant seismic uplift,therefore the wind uplift governs 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. 1/1 =- EV projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.corn Vertical Load Resisting System Design Roof Framing ME Pg= 30 psf ASCE 7-10,Section 7.2 pf= 21 psf Ce= 0.9 ASCE 7-10,Table 7-2 Pfmin.= 25.0 psf Ct= 1.1 ASCE 7-10,Table 7-3 ps= 25 psf 26.1 plf Is= 1.0 ASCE 7-10,Table 1.5-1 CS 0.783 Max Length, L= 9.92 ft Tributary Width,WT= 16 in Dr= 10 psf 13.33 plf PvDL= 3 psf 4 plf Load Case:DL+0.6W Pnet+PPVcos(6)+POL= 34.3 plf Max Moment, Mu= 318 lb-ft Conservatively Pv max Shear 179.2 lbs Max Shear,Vu=wL/2+Pv Point Load= 265 lbs Load Case:DL+0.75(0.6W+5)) 0.75(Pnet+Ps)+PPVcos(6)+PDL= 49 plf Mdown= 457 lb-ft Mallowable=Sx x Fb' (wind)= 1319 lb-ft > 457 lb-ft OK Load Case:DL+S Ps+PPVcos(6)+Ppt= 43 plf Mdown= 400 lb-ft Mallowable=Sx x Fb' (wind)= 948 lb-ft > 400 lb-ft OK Max Shear,V„=wL/2+Pv Point Load= 265 lbs Member Capacity SPF#1/#2 2X6 Design Value CL CF C; Cr Adjusted Value Fb= 875 psi 1.0 1.3 1.0 1.15 1308 psi F„= 135 psi N/A N/A 1.0 N/A 135 psi E= 1400000 psi N/A N/A 1.0 N/A 1400000 psi Depth, d= 5.5 in Width, b= 1.5 in Cross-Sectonal Area,A= 8.25 in2 Moment of Inertia, I„= 20.7969 in4 Section Modulus,Su= 7.5625 in3 Allowable Moment, Mail=Fb'Sxx= 824.4 lb-ft DCR=M�/Mall= 0.40 < 1 satisfactoty Allowable Shear,Va„=2/3Fv'A= 742.5 lb DCR=Vu/Va„= 0.18 < 1 Satisfactory± 1/1 =' EV projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.corn Siesmic Loads Check Roof Dead Load 10 psf %or Roof with Pv 26% Dpv and Racking 3 psf Averarage Total Dead Load 10.8 psf Increase in Dead Load 3.2% OK The increase in seismic Dead weight as a result of the solar system is less than 10%of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on information in pictures and a drawing set titled PV plans-ERIC LAVOIE.The analysis was according to applicable building codes, professional engineering and design experience,opinions and judgments.The calculations produced for this structure's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. 1/1 SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION roil •SYSTEM SIZE:9585W DC.7600W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBCIIEBC), PV-1.0 COVER SHEET SERVICE ENTRANCE •MODULES:(27)LONGI GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS LISTINGS AND INSTALLATION LTD:LR4-60HPB-355M INSTRUCTIONS. PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. Mp MAIN PANEL SE7600H-USSN PV-3.0 LAYOUT •RACKING:RL UNIVERSAL.SPEEDSEAL TRACK ON COMP. •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV-4.0 ELECTRICAL SEE DETAIL SNR-DC-00436 SP SUB-PANEL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 0 SUNRUN METER •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM DEDICATED PV METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ACAC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). 0 DC DISCONNECT(S) •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. •11.25 AMPS MODULE SHORT CIRCUIT CURRENT. CB IQ COMBINER BOX •17.57 AMPS DERATED SHORT CIRCUIT CURRENT(690.8(A)&890.8(B)]. • • •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). ABBREVIATIONS E—I INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE A AMPERE L_I SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT NTERIWTER F: CHIMNEY $ r u n AZ AI AZNUTH COMP COMPOSITION DC DIRECT CURRENT ATTIC VENT #180120 (El EXISTING 1 FLUSH ATTIC VENT VICINITY MAP CNN MYLES STANtleR KYR'AUN...MA oo167331 ESS ENERGY STORAGE SYSTEM PVC PIPE VENT PHOEo FAxo R EXT EXTER1OR METAL PIPE VENT CUSTOMER RESIDENCE: INT INTERIOR ERIC T-VENT ERIC LAVOIE .- MSP MAIN SERVICE PANEL (bA (a. 4 WREN WAY,YARMOUTH,MA. 02664 (N) NEW ? SATELLITE DISH Dennis NTS NOT TO SCALE �'•fit; TEL.(508)555-1234 • OO ON CENTER FIRE SETBACKS APN:YARM-000088-000047 PRE-AS PREFABRICATED �4 7 HARDSCAPE Yarmouth PROJECT NUMBER: PSF POUNDS PER SQUARE FOOT f ,1 able ,4L( 223R-04O AVO IN PHOTOVOLTAIC Wren Way, RSD RANOSHUTDOMN DEVICE PL— PROPERTY LINE South Ydrmouth,M;. (i24) DESIGNER: (4i5)580fi520 ex3 - SUMAIR KHAN SOLAR MODULES n SHEET TRANSFORMERLESB SCALE:NTS HarwiC v VOL REV NAME DATE COMMENTS COVER SHEET VOLTS W WATTS REV:A 11/19/2022 o. LANK L1NO$CAPE SNR MOUNT PAGE POR PORTRAY SNR MOUNT&SKIRT PV_1'0 Tempre_RsACS Gas SITE PLAN-SCALE=1116"=1' fl,1 /7\\*\9 (E)GATE— rMP / \ ? NMI , (N)ARRAY AR-01 WVPM O— ,,, (E)RESIDENCE Y dihk ,,,,,,� (N)ARRAY AR-02 +0 i * o. (N)ARRAY AR-03 ,•Oh , .. . ..:, a sunrun 1 .... • . . . . .,. +` #180120 4\_. aw MYLES STNvarN BLVD.TwxroN,w.MOM, / (E)GATE FAX 0 ` CUSTOMER RESIDENCE: • -° ERIC LAVOIE • • . 40 WREN WAY,YARMOUTH,MA, /S 4 02664 2 ° ~2y • .1ARRAY TRUE G PV AREA 7EL.(508)555-1234 -9,1- PITCH AZIM AZIM (SOFT) j0'PN:YARM-000068-000047 JB ER: AR-01 23° 44° MA 58° 176.5 223R-04PROECT 0LAVONUM d' 4AR-02 23° 224° 238° 58.8 \z/ DESIGNER: (415)580-6920 ea3 AR-03 23° 224° 238° 294,1 SUMAIR KHAN SHEET SITE PLAN REV:A 11/19/2022 PAGE PV-2.0 rempae_.e,xm•0 96 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait MAXMAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-Ot COMP SHINGLE•RLU 2-Story 2X6 RAFTERS 9'-11" 16" COMP,SEE DETAIL SNR-DC-00436 4'-0' 1'-11" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREW AR-02 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 5'-8" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 5'-4" 2'-1" 4'-0" 1'-11" STAGGERED 5/16".2.5"MIN.EMBEDMENT DETAIL SNR-DC-00436 AR-03 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 9'-11" 16" RL UNIVERSAL,DETTAILAILPEE S NR-DC-00436 EAL TRACK ON COMP,SEE 4'-0' 1'-11" STAGGERED D1-AR-01-SCALE:1/8"=V-0" AZIM:44" PITCH:23° 1'-5"#—' 29'-1" a o a o - 1-6 INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED 0.5., PRIOR TO PROCEEDING W/INSTALLATION. I n n n n S o ti aTRUC 10'-4" ONL •IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" .fy3Na8444 a G a 8 BOUNDARY REGION OF ANY ROOF PLANE o�o� VINCENi�4�6�, 6 8 -t 5'-4"TYP t- EDGES(EXCEPT VALLEYS),THEN MWUMVANEZA w A I h n ATTACHMENTS NEED TO BE ADDED AND CIVIL 0 1'-g OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: ..,j cN�� �I "ALLOWABLE ATTACHMENT SPACING '' .OaKIE0 it 42.-6 t 1'-� INDICATED ON PLANS TO BE REDUCED BY 50%. "ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS D2-AR-02-SCALE:1/8"=1'-0" D3-AR-03-SCALE:1/8"=1'-0" s u n r u n AZIM:224 AZIM:224° PITCH 23 PITCH:23° 8180120 1,_i'•_} 29'_1" - —}T_10", as r668e swnM Kw.rwurw.w ONO.7J, MOM 0 17'_5„ 1 '-" t _ r • I.6" CUSTOMER RESIDENCE: - - - - - — "--" ERIC LAVOIE I 1.-0„ ��� 004 WREN WAY,YARMOUTH,MA, 0 0 0 0 a n n 1h -, 10'-4' TEL.(508)555-1234 -10" 1111.11,111 APN: EC 8 PROJECTT NUMBER: 223R-0401AVO 1'-2"-' DESIGNER' (415)56043920 ex3 SUMAIR KHAN SHEET LAYOUT REV:A 11/19/2022 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 re,,Ose_,.non_4 0 86 120/240 VAC SINGLE PHASE SERVICE NOTE:TOTAL PV BACKFEED=40A OMETER#: USED FOR INTERCONNECTION EVERSOURCE 2370023 CALCULATIONS UTILITY GRID I //-SUPPLY SIDE TAP 0 t I EXISTING 100A (N)LOCKABLE BLADE TYPE (N)MA SMART MAIN BREAKER FUSED AC UTILITY SOLAREDGE TECHNOLOGIES: DISCONNECT REVENUE SE7800H-USSN METER 7600 WATT INVERTER JUNCTION BOX PV MODULES /,1 `2., OR EQUIVALENT (� LONGI GREEN ENERGY TECHNOLOGY EXISTING �A:JJ J� / CO LTD:LR4-6OHPB-355M POA MAIN o�,NEL VI O J `f _ ,�i I *$// (27)MODULES FACILITY �J OPTIMIZERS WIRED IN: LOADS 40A FUSES I I (1)SERIES OF(14)OPTIMIZERS low SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT L (1)SERIES OF(13)OPTIMIZERS D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R,60A UTLITY SIDE OF CIRCUIT COMPLIANT P401 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n 3 3/4"EMT OR EQUN. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 MIMES.STuaSH N.TMxrtON.W MAW. PHONE CUSTOMER RESIDENCE: ERIC LAVOIE 40 WREN WAY,YARMOUTH,MA, 02664 MODULE CHARACTERISTICS P401 OPTIMIZER CHARACTERISTICS: TEL.(508)555-1234 LONGI GREEN ENERGY MIN INPUT VOLTAGE: 8 VDC APN:YARM-000088-000047 TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: LR4-60HP6-355M: 355 W MAX INPUT ISC: 11.75 ADC 223R-040LAVO OPEN CIRCUIT VOLTAGE: 40.6 V MAX OUTPUT CURRENT: 15 ADC MAX POWER VOLTAGE: 34.6 V SHORT CIRCUIT CURRENT: 11.25 A DESIGNER: (415)580fi920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 SUMAIR KHAN SYSTEM SIZE: 9585 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 14 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:A 11/19/2022 SYSTEM OPERATING CURRENT: 23.96 A SYSTEM SHORT CIRCUIT CURRENT. 30 A PAGE PV-4.0 lernpble varsia,_I.086 /\WARNIN INVERTER 1 NOTES AND SPECIFICATIONS. _ •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE PHOTOVOLTAIC DC DISCONNECT 110.21(B).UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ. AXIMUM SYSTEM VOLTAGE: 4Bo 1/ •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON UNE AND LOAD WORDS.COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN AXIMUM CIRCUIT CURRENT: 30 A •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN THE OPEN POSITION AX RATED OUTPUT CURRENT OF THE CHARGE •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT ONTROLLER OR DC-TO-DC CONVERTER(IF INSTALLED):®A INVOLVED. LABEL LOCATION' •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S). SIGNS AND LABELS.UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). LABEL LOCATION. •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S).NEC 2020 690.13(B) INVERTER(S),DC DISCONNECT(S) PER CODE(S)CEC 2019 69053,NEC 2017 690 53 WARNING:PHOTOVOLTAIC ZNWARNING— POWER SOURCE LABEL LOCATION DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS -— -- _------- AND PV SOLAR ELECTRIC PER CODE(S)CEC 2019:690.31(GN3),690.31(G)(4) SYSTEM NEC 2017 69031(GN3),880.31(GN4)IFC 2012'. _ J 805.11.1.4 CAUTION : LABEL LOCATION UTILITY SERVICE METER AND MAIN SERVICE PANEL PER CODE(S):NEC 2020 705.12(C) AWARNING RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM 1�i DO NOT RELOCATE THIS SOLAR PANELS ON ROOF OVERCURRENT DEVICE LABEL LOCATION INSTALLED WITHIN 3'OF RAPID SHUT DOWN LABEL LOCATION: SWITCH PER CODE(S).NEC 2020.69056(C)(2),IFC s u n r u n ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3 OCPD(IF APPLICABLE) PER CODE(S)NEC 2020 ,1' 1] 705 121B113N21 WARNING SOLAR PV SYSTEM EQUIPPED Till #180120 PHOTOVOLTAIC SYSTEM 1 111 MYLES SuwaMl xw 1wMYw.VA o1m.m1 COMBINER PANEL WITH RAPID SHUTDOWN 1 111 OW o DO NOT ADD LOADS III 11 CUSTOMER RESIDENCE: 11_ ERIC LAVOIE LABEL LOCATION MAIN PANEL(INT) •t 440WEN WAY,YARMOUTH.MA, PHOTOVOLTAIC AC COMBINER(IF PEAPR CODES) 3" TURN RAPID SHUTDOWN INVERTER (EXT) PER CODE(S)'.NEC 2020 705 12(D)12N3)(c) SWITCH TO THE"OFF' w1M1Mu SERVICE ENTRANCE TEL.(508)555-1234 POSITION TO SHUT DOWN —PRODUCTION METER APN.YARM-015088-000547 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE AC DISCONNECT— PROJECT NUMBER: MUM AC OPERATING CURRENT.31.67 AMPS SHOCK HAZARD IN THE ARRAY. 223R-040LAV0 ANAL OPERATING AC VOLTAGE 240 VAC Ell DESIGNER: (415)5806920 ex3 LABEL LOCATION. 40 WREN WAY, YARMOUTH, MA, 02664 SUMAIR KHAN AC DISCONNECT(S).PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. ".—s SHEET PER CODE(S):NEC 2020 69054 LABEL LOCATION. PER CODE(SI NEC zo2o'7a5.10,710J0 SIGNAGE ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A 11/19/2022 PER CODE(S):NEC 2020:890.56(C) PAGE PV-5.0 T•mpee MM. N9 =- EV projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.com 11/21/2022 RE:Structural Certification for Installation of Residential Solar ERIC LAVOIE:40 WREN WAY,YARMOUTH,MA,02664 Attn:To Whom It May Concern This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report,the roof is made of Composite shingle roofing over roof plywood supported by 2X6 Rafters at 16 inches.The slope of the roof was approximated to be 23 degrees. After review of the field observation data and based on our structural capacity calculation,the existing roof framing has been determined to be adequate to support the imposed loads without structural upgrades. Contractor shall verify that existing framing is consistent with the described above before install.Should they find any discrepancies,a written approval from SEOR is mandatory before proceeding with install.Capacity calculations were done in accordance with applicable building codes. Design Criteria Code 2015 IRC(ASCE 7-10)-CMR 780 9th Ed Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 140 mph PV Dead Load DPV 3 psf Exposure C Roof Live Load Lr 20 psf Ground Snow S 30 psf If you have any questions on the above, please do not hesitate to call. STRUCT ;. ONL Sincerely, �SH oFMgss90 ti 4' VINCENT 60, Vincent Mwumvaneza, P.E. MWUMVANEZA EV Engineering, LLC N�CIVIL projects@evengineersnet.com O 4,0 ��Q http://www.evengineersnet.com •;� oNA1.ENG\� 1/1 EVWIN IL 7 - s projects@evengineersnet.com 276-220-0064 mom ENGINEERS http://www.evengineersnet.com Structural Letter for PV Installation 11/21/2022 Job Address: 40 WREN WAY YARMOUTH, MA,02664 Job Name: ERIC LAVOIE Job Number: 112122 EL Scope of Work This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing.All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Table of Content Sheet 1 Cover 2 Attachment checks 3 Snow and Roof Framing Check 4 Seismic Check and Scope of work Engineering Calculations Summary Code 2015 IRC(ASCE 7-10)-CMR 780 9th Ed Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 30 psf Wind Load (component and Cladding) V x mph Exposure C References NDS for Wood Construction STRUCT ONL FAO'ok OF MgSS,gc Sincerely, 4� VINCENT r" MWUMVANEZA CIVIL Vincent Mwumvaneza, P.E. EV Engineering, LLC . NG\o proiects@evengineersnet.com ONAIE http://www.evengineersnet.com 1/1 =- EV j projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.com Wind Load Cont. Risk Category= II ASCE 7-10 Table 1.5-1 Wind Speed(3s gust),V= mph ASCE 7-10 Figure 26.5-1A Roughness= C ASCE 7-10 Sec 26.7.2 Exposure= �` ASCE 7-10 Sec 26.7.3 Topographic Factor, KZT= 1.00 ASCE 7-10 Sec 26.8.2 Pitch= 23.O Degrees Adjustment Factor,A= 1.35 ASCE 7-10 Figure 30.5-1 a = 2.20 ft ASCE 7-10 Figure 30.5-1 Where a:10%of least horizontal dimension or 0.4h,whichever is smaller,but not less than 4%of least horizonta,dimension or 3ft(0.9m) Uplift(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= -29.3 -41.3 -65.1 Figure 30.5-1 Pnet=0.6 x A x KZT x Pnet30)= 23.75 33.46 52.75 Equation 30.5-1 Qownpressure(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= 15.7 15.7 15.7 Figure 30.5-1 Pnet=0.6 x KZT x Pnet30)= 12.73 12.73 12.73 Equation 30.5-1 Rafter Attachments:0.6D+0.6W(CD=1.6) Connection Check Attachement max.spacing= y ft 205 lbs/in Lag Screw Penetration 2.5 in Allowable Capacity= 512.5 0.6D+0.6W Dpv+0.6W Zone Trib Width Area(ft) Uplift(lbs) Down(Ibs) 1 5.3 11.4 250.1 179.2 2 5.3 11.4 360.7 179.2 3 2 4.7 241.0 74.4 Max= 360.7 < 512.5 CONNECTION IS OK 1. Pv seismic dead weight is negligible to result in significant seismic uplift,therefore the wind uplift governs 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. 1/1 EV projects@evengineersnet.com 276-220-0064 lama ENGINEERS http://www.evengineersnet.com Vertical Load Resisting System Design Roof Framing _ Pg= 30 psf ASCE 7-10,Section 7.2 pf= 21 psf Ce= 0.9 ASCE 7-10,Table 7-2 Pfmin.= 25.0 psf Ct= 1.1 ASCE 7-10,Table 7-3 ps= 25 psf 26.1 plf Is= 1.0 ASCE 7-10,Table 1.5-1 CS 0.783 Max Length,L= 9.92 ft Tributary Width,WT= 16 in Dr= 10 psf 13.33 plf PvDL= 3 psf 4 plf Load Case:DL+0.6W Pnet+Ppvcos(6)+Ppt= 34.3 plf Max Moment, Mu= 318 lb-ft Conservatively Pv max Shear 179.2 lbs Max Shear,Vu=wL/2+Pv Point Load= 265 lbs Load Case:DL+0.75(0.6W+S)) 0.75(Pnet+Ps)+PPVcos(6)+PDL= 49 plf Mdown= 457 lb-ft Mallowable=Sx x Fb'(wind)= 1319 lb-ft > 457 lb-ft OK Load Case:DL+S Ps+Ppvcos(6)+Poi= 43 plf Mdown= 400 lb-ft Mallowable=Sx x Fb' (wind)= 948 lb-ft > 400 lb-ft OK Max Shear,V„=wL/2+Pv Point Load= 265 lbs Member Capacity SPF#1/#2 2X6 Design Value CL CF C; Cr Adjusted Value Fb= 875 psi 1.0 1.3 1.0 1.15 1308 psi F„= 135 psi N/A N/A 1.0 N/A 135 psi E= 1400000 psi N/A N/A 1.0 N/A 1400000 psi Depth, d= 5.5 in Width, b= 1.5 in Cross-Sectonal Area,A= 8.25 in2 Moment of Inertia, Ixx= 20.7969 in4 Section Modulus,Sxx= 7.5625 in3 Allowable Moment, Main= Fb'Sxx= 824.4 lb-ft DCR=MU/Mail= 0.40 < 1 Allowable Shear,Vali=2/3F5'A= 742.5 lb DCR=V /Va1i= 0.18 < 1 1/1 EV projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.com Siesmic Loads Check Roof Dead Load 10 psf %or Roof with Pv 26% Dpv and Racking 3 psf Averarage Total Dead Load 10.8 psf Increase in Dead Load 3.2% OK The increase in seismic Dead weight as a result of the solar system is less than 10%of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on information in pictures and a drawing set titled PV plans-ERIC LAVOIE.The analysis was according to applicable building codes, professional engineering and design experience,opinions and judgments.The calculations produced for this structure's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. 1/1