HomeMy WebLinkAboutBLD-23-004817 r. in a- /Z643%%4,
ONE & TWO FAMILY ONLY- BUILDING PERMIT
Town of Yarmouth Building Department ('-o -s•-....:•„;\
1146 Route 28, South Yarmouth,MA 02664-4492
508-398-2231 ext. 1261 Fax 508-398-0836al
i .
Massachusetts State Building Code,780 CMR
Building Permit Application To Construct, Repair, Renovate Or Demolish .= y
a One-or Two-FamilyDwelling
ti "" _ f
g �
This Section For Official Use Only
Building Permit Number: 13(4)ya3 -04(.421 1 Date Applied- p ii II 0 i N a r�E toA R 1 M E N T
,/-' i
Building ffteial(Print N e) ignature Date
SECTION 1:SITE INFORMATION
1.1 Property A dress: 1.2 Assessors Map&Parcel Numbers
AZ Adftittee Or'� /z11 S3
1.1 a Is this an accepted street?yes /7 no Map Number Parcel Number
1.3 Zoning Information: 1.4 Property Dimensions:
D • 99 ac.
Zoning District Proposed Use Lot Area(sq ft) Frontage(ft)
1.5 Building Setbacks(ft)
Front Yard Side Yards Rear Yard
Required Provided Required Provided Required Provided
1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System:
Public 0 Private CI
_ Outside Flood Zone?
Check if yes❑ Municipal 0 On site disposal system 0
SECTION 2: PROPERTY OWNERSHIP
2.1 Owner'of Record:
£ Sa,.i Aril-el' /t I t 4.4- Dre-e yAr y
Name(Print) City,State,ZIP / /� dad
No.and Street Telephone Email Address
SECTION 3:DESCRIPTION OF PROPOSED WORK=(check all that apply)
New Construction 0 Existing Building❑ Owner-Occupied 0 [ Repairs(s) 0 Alteration(s) Cl Addition 0
Demolition ❑ Accessory Bldg. 0 Number of Units Other 'iecify: A s/4'Je
Brief Description off �G Proposed Work2:j �' S 1, 9( 2arr eJ. ai4 f�,('
per / 10.1 e �'r
C:I/424`e.(d- So/4( 711 r.v:.1(y`i..s1, Eli c/ an,€/jam) 4dJe,Z e.II
SECTION 4:ESTIMATEIG CONSTRUCTION COSTS.
Item Estimated Costs:
(Labor and Materials) Official Use Only
-
I.Building $ 1 C ‹-D-0 I. Building Permit Fee:$j5 Indicate how fee is determined:
2.Electrical $ ��/ El Standard City!?own Application Fee
1 0 Total Project Costa(Item 6)x multiplier x
3.Plumbing $ 2. Other Fees: $
4.Mechanical (HVAC) $ List e
5.Mechanical (Fire
Suppression) $ Total All Fees:$
6.Total Project Cost: $ / Check No. Check Amount: Cash Amount:
J a2j silt ❑Paid in Full El Outstanding Balance Due:
SECTION 5: CONSTRUCTION SERVICES
5.1 Construction Supervisor License(CSL) j
itvL s Licenses �Number tratio Date
Name of CSL Ho er
Po fOx 7 0-0 List CSL Type(see below)
No.and Street Ty a Description
MA 62 6J1 / Unrestricted(Buildings up to 35,000 cu.ft.)
City/Town,State,ZIP Restricted lea Family Dwelling
M Masonry
RC Roofing Covering
WS Window and Siding
s ,�^ / / SF Solid Fuel Burning Appliances
V�41 � clL�es 0_4,441,34 I Insulation
Telephone Email address LLC.GGDP% _ D Demolition
5.2 Registered Home Improvement Contractor(HIC) /6'Q7/ g
L, HIC Registration Number pirat on Date
HIC Company Nanr or HIC Regi trpnt Name
oN .and Street
rr s, ma ad 6 S3 Sad Email address
City/Town,State,ZIP Telephone
SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6))
Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide
this affidavit will result in the denial of the Issuance of the building permit.
Signed Affidavit Attached? Yes Ur"----
No 0
SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WREN
OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT
I,as Owner of the subject property,hereby authorize
to act on my behalf,/in all/matters relative to work authorized by this building permit application.
S4 o P,t - 4/S/��
✓J��
.2
Print Owner's Name(Electronic Signature) Date
SECTION 7b: OWNER'OR AUTHORIZED AGENT DECLARATION
By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information
contained in this application is true and accurate to the best of my knowledge and understanding.
£tF1 st-t" �`, G).iti(j,G P • Owner'suthorized Agent' me(Electronic Signature) Date
NOTES:
I. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor
(not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration
program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at
www.mass.$ovIota Information on the Construction Supervisor License can be found at www.mass.nov/dps
2. When substantial work is planned,provide the information below:
Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch)
Gross living area(sq.ft.) Habitable room count
Number of fireplaces Number of bedrooms
Number of bathrooms Number of half/baths
Type of heating system Number of decks/porches
Type of cooling system Enclosed Open
3. "Total Project Square Footage"may be substituted for"Total Project Cost"
'I
i
Commonwealth of Massachusetts Hoisting Engineer
DiVIston of Occupational Lcensurt'
Restricted to:
'; ;i r ti HE-1C-Telescoping Booms w/o Cables
`?.:++1T,flu L r°il '? 'r=r HE-2A-Excavators
,
HE-088492 tcpires 0410212024
TIMOTHY S l3OLMES r
16 QUARTERMASTER OR
BREWSTER MA 02631
I i ti`
t i` ' DIG SAFE Call Center:(888)344-7233
In case of accident call: (508)820-1444
Commissioner - '-- Contact OPSI:(617)727-1200or visit www.mass.govldpllopsi
Commonwealth of Massachusetts
-lift Division of Occupational Licensure Construction Supervisor
Board of Building Regulations and Standards UnPestricted-Buildings of any use group which contain
t i i r less than 35,000 cubic feet(991 cubic meters)of enclosed
:onstirsn SrVrsor space.
.. :r
CS-068126 ,..ifilr 6pires:04i02t2024
TIMOTHY S l+OL i'zz, f
16 QUARTERMAS ,+ tr
BREWSTER r .f 3Ar
- r 4:"
F `4111.f t,l I:�l e Failure to possess a current edition of the Massachusetts
State Building Code is cause for revocation of this license.
Commissioner :'u,L.:..i , '`('4,,,_i.J& For information about this license
i CaN(617)727-3200 or visit www.mass.govidpl
Office of Concoo,..mrior Aft:rirti Y.tlusine,,+11erprl.it n,1
HOME IMPROVEMENT CONTRACTOR Registration valid for individual use only
Tl i'E:I t(. before toe expiration date. If found return to:
Registration Expiration Office of Consumer Affairs and Business Regulation,
iI uf1f1 uii C'.'fJ,r 1000 Washington Street -Suite 710
iNWIND,I t r,
Boson.MA 02"18
o cRArdBr RlzY HIGHWAY t alid without signature
LEANS MA MA 02653 Unclfal-rrcreiary
Ac RIG CERTIFICATE OF LIABILITY INSURANCE aAUEwimvirrn
TH s cornFEATE IS ISSUE)AS A MATTER OF INFORWITHON ONLY AND COWERS NO RIGHTS UPON THE CERE1ICATE HOMER.THIS
CERTIFICATE DOES MDT TNELY OR IE€iATMELY MEM EXTOM)OR ALTER THE COVERAGE BY THE POLICES
BELOW ills CERTIFICATE OF POURAWE DOES NOT CONSTITUTE A CONI"RACT 1ETWEBI THE IMS O POURERS). AUTIentmeD
REIMESENTATIVE OR PRODUCER AM)TIE CERTIFICATE MI ER.
IiIPL1RTANT: If the c erbicik holder is an ADDITIONAL INSURED.the poicy(Ies)must have ADDITION&POURED provisions ar be endorsed.
If SUBROGATION IS WAIVED.she to the tewns and conditions of the policy.certain paieies may repwe an endorsement A statement on
this mate does oat°order rights to the cerNbode holder in lieu of such _
Prscouaen Lhrda OINEWan
DOWLING&O NEIL INSURANCE AGENCY a r (50B)775-1820 I raft*
973 IYAMIOUGH RO 11111ffiRMINNOMINNO OCIMB haaE MRCS
HYMENS MA 02E01 I' A: AIM M UTUAL II CO 33758
SUNWtND 11C MOMC:
agar:
PO BOX 7I>1) aE
BREWSTER MA 02831 rlrrltiIEtF:
CONERAGNS CERTIFICATE NUMBER: 80t067 REVISION RUINER:
THIS IS TO CERTIFY THAT THE POLICES Cr INSUFLANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAIED ABOVE FOR THE POLICY PERIOD
INDICATED. PACTIVRTHSTANDRIG ANY REDUREENT,TERM OR COMMON OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUE)OR MAY PERTAIN,THE INSURAPS=AFFORDED BY THE POLICES DESCRNED Hal IS SUBECT TO ALL THE TERMS,
EXCLUSIONS AND COICITIONS OF SUCH POLICES.UNITS MOM MAY NAVE BEEN REDUCE)BY PAD COMAS.
rIHR TYPE OF MINUNIINCE Nob two PCUCYME YM) MESIMPIVYTI
E?R
CONIMERCIALMENEMINLMALAY EACH OCCUN #
MIME-Ra RENTED
r 'E ❑OCCUR P a
hECr EDrP Ow mesas* a
PIA PErmONAL&AMINJURY #
GEM R
UNIT*CUES PM CEMERALROGREGAIE
IJ x EI LOG PRCIENJC711 CONFIOPs ao a
anew
ionamemomourti caliereEo MOLE UIET
Si=WM
a
ANY*!TO SCORN'NARY Oyer puma a
CURED SCIEDIAEO HOLY NARY Vet man* a
MIOSCELT AUTOS
r MIITJSOFLY _ ear=Mama
a
ice.ALlA6 caul EACH OCCLR
EsnEaa LMH txOE PM AOarE&IATE #
CEO I rr omens a rewatuer MENINX* }G I Wove I I a
ArM LIINIRAY
veromvark1EeAtEyiEY.t YEN
141Tk ELEA04ACCIE �W a
A w Q ro► MA VW C100d0175t> ?A 0tlf'15t 081'15f20"�3INININWINIY EL[MHt ArE-Ei19ELC7rEf # 500J000
Cf Tsoresbelow ELCREME-PbLk'rLilt a MOAOD
PM
osocar owOFineaMICelaILCCA $Iv®erxES MGM 1t4 Rimesas.+rt+..Pe.NENNRIN6 Rom amp nimam.
Workers'Caseaensation benefits will be paid to Massachusetts employees air_Pursuant to Endorsement NE 20 03 08 B.no awn is given b pay
dims for benefits to emploraes n states other than Massachusetts Wthe hewed hires.or has hired those employees outside at Massachusetts.
Ttis cet hcale of rmzanae shores the policy in farce an the dale that t is caeca*was issued(unless the ewsiraion dale on the above poicy precedesthe
issue date of this certificate of as5uahae). The statues of this coverage can be'undated daft by accessing the Proof of Coverage-Coverage Ve Ncaiarr
Suds bah at wwvr. ., _;t
CERTIFICATE HOLDER CANCELLATION
SHOULD AMY OF TIE AiBO E DOOMED POLICES LE CAIICE r R)Btu
THE EIIPIROMON DATE THEREOF, NOIICE ttl.L. BE OELINIEREO IN
ACCORDANCE WI HTHEPOLICYPIROUL3IONS.
AUDIONIZEDHISMOVENTAMIE
Daniel M Croviey,CPCU,vide President—Residual Mabel WCRIBIM
—
01t01-2015 ACORD CORPORATION. At rights reserved_
ACORD 25(MGM) The ACORD name and logo are registered marks of ACORD
The Commonwealth of Massachusetts
Department of Industrial Accidents
Office of Investigations
600 Washington Street
Boston,MA 02111
www.mass.gov/dia
Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers
Applicant Information Please Print Legibly
Name(Business/Organization/Individual): SunWind LLC
Address:PO Box 700
City/State/Zip:Brewster, MA 02631 Phone#:508-246-6350
Are you an employer?Check the appropriate box: Type of project(required):
1.11 I am a employer with 3 4. 0 I am a general contractor and I
employees(full and/or part-time).* have hired the sub-contractors 6. El New construction
2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. 0 Remodeling
ship and have no employees These sub-contractors have 8. []Demolition
working for me in any capacity. employees and have workers' 9. ❑Building addition
[No workers'comp.insurance comp.insurance.#
required.] 5. 0 We are a corporation and its 10.0 Electrical repairs or additions
3.0 I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions
myself.[No workers' comp. right of exemption per MGL 12.0 Roof repairs
insurance required.]t c. 152,§1(4),and we have no Solar
employees. [No workers' 13.®Other
comp.insurance required.]
*Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information.
t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such.
tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have
employees. If the sub-contractors have employees,they must provide their workers'comp.policy number.
I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site
information.
Insurance Company Name: Dowling & O'Neil Insurance Agency
Policy#or Self-ins.Lie.#•VWC1006017569202jA Expiration Date:06/15/2022b
Job Site Address: 12 Dundee Drive City/State/Zip:Yarmouth MA,02675
Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date).
Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a
fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine
of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of
Investigations of the DIA for insurance coverage verification.
I do hereby certify under the pains and penalties of petjury that the information provided above is true and correct.
Signature: Y r 6E Date: 12/27/22
Phone#:508-246-635
Official use only. Do not write in this area,to be completed by city or town official
City or Town: Permit/License#
Issuing Authority(circle one):
1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector
6.Other
Contact Person: Phone#:
l i
YARMOUTH TOWN CLERK
=. r a y TOWN OF YARMOUTH
, x 1146 ROUTE 28, SOUTH YARMOUTH, MA 02664-4451 �� � �
Telephone(508)398-2231 Ext. 1292-Fax(508)398-0836
OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE
APPLICATION FOR
CERTIFICATE OF APPROPRIATENESS
Application is hereby made for issuance of a Certificate of Appropriateness under Section 6 of Chapter 470, Acts of 1973 as
amended, for proposed work as described below&on plans, drawings, photographs, &other supplemental info accompanying this
application. PLEASE SUBMIT 4 copies OF SPEC SHEET(S), ELEVATIONS,PHOTOS,&SUPPLEMENTAL INFORMATION.
Check All Categories That Apply: Indicate type of Building: Commercial Residential
1) Exterior Building Construction: New Building Addition _Alterations Reroof Garage
Shed polar Panels Other:
2) Exterior Painting: Siding Shutters Doors _Trim Other:
3)Signs/Billboards: New Sign Change to Existing Sign
4) Miscellaneous Structures: Fence Wall Flagpole Pool Other:
Please type or print legibly:Address of proposed work: /9Z A.• .J(ie e- ilr,v.. Map/Lot# /1 s/ci
Owner(s): S.:Scz,.J re l-1� Phone#:2 '/ 1- /h c3� 0 a
All applications must be submitted by owner or accompanied by letter from owner approving submittal of application.
J.7? O.' 1 a 1 t,`-C. eY,� 1 Pe f " 4 ,u 7 Year built: J RI
Mailingaddress: ) �,s �
Email: bile e� J ittt of) 6 C/ e fv:t4 i 1.(o/-. Preferred notification method: Phone 1,---Email
Agent/contractor: ,Sv'r J£Jit-31 L l c Phone#: Se'3 d V6 65S
Mailing Address: Pe e, _7CL' gi l Czo$1
Email:-7 +6/ir e . . S,..4,I(>J,.;e/LL C = 6..,p-.- Preferred notification method: Phone `,- Email
Description of Proposed Work:
j e`t to f ' c,'6-,cis_ ,-t ( �,% r�`4 5 r , €�?.,
�f
Signed(Owner or agen 4+7 /14 !.4-!--,'- `c JDate: !'-/S"IR e r .1
Owner/contractor/agent is aware that a permit is required from the Building Department.(Check other departments,also.)
> If application is approved,approval is subject to a 10-day appeal period required by the Act.
> This certificate is good for one year from approval date or upon date of expiration of Building Permit,whichever date shall be later.
> All new construction will be subject t/o inspection by OKH.OKH-approved plans MUST be available on-site for framing&final inspections.
For Committee use only: V Approved Approved with Modifications Denied
Rcvd Date: l/17)2 3 Reason for Denial:
Amount 110` 1,0
Cash/CK#:-3; ��' ?
Signed: Fit: (114ta _ft:_tri-
Rcvd by: L1 �,
45 Days: 7
!i j i •
Date Signed )G-j
1 APPLICATION#: 23 -7)O
A s
.Y `o. TOWN OF YARMOUTH
° Y41 OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE
1146 ROUTE 28, SOUTH YARMOUTH, MASSACHUSETTS 02664-4451
Telephone(508)398-2231 Ext.1292 Fax(508)398-0836
STATEMENT OF UNDERSTANDING
CHANGES TO AN OLD KING'S HIGHWAY APPROVED PLAN
As property owner/contractor/agent for construction at Ouvid - tO rtV-__ ,
Map/Lot I LI 315-3 C/A# 9; A 1Oy- Approval Date: d' i' f?;
I certify that I understand the following requirements regarding any changes that may
be required for this project:
In accordance with paragraph 2(a) of section 1.03(General Procedures) of the OKH 972
CMR Rules and Regulations: Only minor changes may be approved by the Committee
without the filing of a new application and a new hearing. Minor changes include
alterations that can be done without a detrimental impact on the overall appearance of
the project such as altering a single window or door change or a minor change of
colors. All minor changes by amendment will require the local Committee's or its
designee's approval.
All changes to previously OKH approved plans require notification to and approval
from the local OKH Committee. Change requests must be submitted to the Committee
in writing on the appropriate request form, which may be obtained from the OKH office.
All change approvals must be obtained before incorporating the change into the
project.
If the change has been implemented prior to receipt of OKH approval, a Minor Change
approval or Certificate of Appropriateness application for the revised plans is still
required and will result in a doubled filing fee for the appropriate category of work.
Failure to comply with the above statements will result in the Building Department
issuing a stop-work order or delaying issuance of an Occupancy Permit or final
inspection approval.
I have read and understand the above statements.
Date: - I- _ k � Signed:
(Owner/Contra or/Agent)
Signed: ( ; ILt
(Chairman, Old King's Highway ommittee)
H:\OKH COMMITTEE\Application Forms Statement of Understanding 2015 docx
Updated 12/2015
A -
'GENERAL SPECIFICATION SHEET
Project Address:
FOUNDATION: Material: Exposure(Not to exceed 18"):
CHIMNEY: Material/Color: GUTTERS: Material/Color:
ROOF: Material: Pitch(7/12 min) Height to Ridge: Color:
SIDING: Material/Style: Front: Sides/Rear: COLOR CHIPS
Color: Front: Sides/Rear:
TRIM: All windows&doors to be trimmed with: 1x 4 1x5 (Circle one.)
Material: Color:
DOORS: Qty: Material: Color:
Style/Size(if not listed/shown on elevations):
STORM DOORS: Qty: Material: Color:
GARAGE DOORS: Qty: Mat'I: Style: Color:
WINDOWS: Qtv/side:: Front Left: Right: Rear: Color:
Manufacturer/Series: Material:
Grilles (Required): Pattern(6/6,2/1,etc.) Grille Type: True Divided Lite:
Snap-In: Between Glass: Permanently Applied: Exterior Interior
STORM WINDOWS: Qty: Material: Color:
SHUTTERS: Mat'l: Style: Paneled Louvered Color:
SKYLIGHTS: Qty: Fixed Vented Size Color: •"i 43
DECK: Size: Decking Mat'I: Color:
Railing Mat'l: Style: Color:
WALLS/FENCES*(Max 6'height): Height: Mat'I:
Style: Color:
(Show running footage& location on plot plan.) *Finished side of fence must face out from fenced in area.
UTILITY METERS/HVAC UNITS: Location: Screening:
LIGHTS: Qty: Style: Color:
Lo ation(s):
SU/Ar 14, .�
L . 3ty: Material: Color:
Location(s):
Additional information: 4 G 3`7,S h A J/ L1A61r `' S e/0' J^ pets[/J- O,n1
/cst..> pre 41/6 if/A tie fete 1, -
2-General
APPLICATION#: -✓A-DaZ
} TOWN OF YARMOUTH
1146 ROUTE 28, SOUTH YARMOUTH, MA 02664-4451
Telephone(508)398-2231 Ext. 1292—Fax(508)398-0836
OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE
,t APPLICATION FOR
CERTIFICATE OF APPROPRIATENESS
Application is hereby made for issuance of a Certificate of Appropriateness under Section 6 of Chapter 470, Acts of 1973 as
amended, for proposed work as described below&on plans,drawings, photographs, &other supplemental info accompanying this
application. PLEASE SUBMIT 4 copies OF SPEC SHEET(S),ELEVATIONS, PHOTOS,&SUPPLEMENTAL INFORMATION.
Check All Categories That Apply: Indicate type of Building: Commercial Residential
1) Exterior Building Construction: New Building Addition _Alterations Reroof Garage
Shed _egolar Panels Other:
2) Exterior Painting: Siding Shutters Doors _Trim Other:
3) Signs/Billboards: New Sign Change to Existing Sign
4) Miscellaneous Structures: Fence Wall Flagpole Pool Other:
Please type or print legibly:
Address of proposed work: / oC 0„,J(lee- Map/Lot# J`/3/Ti
Owner(s): S ,Sa,%) PO rit 'f Phone#:7 ) �/ 0/`/
All applications must be submitted by owner or accompanied by letter from owner approving submittal of application.
Mailing address: J� OL14Pe e /fi?t1.0 7ei7h, 11ipc it +✓fie 7 Year built: /9 c !
Email: /OVP. S 6tJ e pl.;/ =e-of,. Preferred notification method: Phone Y Email
Agent/contractor: , C-j ti J LI L Phone#: „"fit 3 96 is 3Sc'
Mailing Address: Pe g&1C 7t L 1 ✓i-fret / ,4 C, 63 I
Email:1)64€ ye Si t J,rJILL C. o 4:0 fr, Preferred notification method: Phone 1. Email
Description of Proposed Work: N f zx// (at) { f 0'-ee/) et-,
c AAv c '1 t- - 5 4;, Q,��t X. 5J� e0 --1 f/ t eo.-s�- .1;1.
Signed(Owner or agent -71---44,7 ; !� ,_�' *,�—�� 1 z"c pate: 'f `a? !.s
> Owner/contractor/agent is aware that a permit is required from the Building Department.(Check other departments,also.)
• If application is approved,approval is subject to a 10-day appeal period required by the Act.
> This certificate is good for one year from approval date or upon date of expiration of Building Permit,whichever date shall be later.
• All new construction will be subject to inspection by OKH.OKH-approved plans MUST be available on-site for framing&final inspections.
For Committee use only: Approved Approved with Modifications Denied
Rcvd Date: l/1.7Pa Reason for Denial_:
Amount 1` ID
Cash/CK#:-3;6711
Rcvd by: 1--')-.'
Signed:
45 Days:
Date Signed:
1 APPLICATION#: 23 —AO--
)
SIGN SPECIFICATION SHEET
Proiect Address: Year Built:
Check one: New Sign Addition/Alteration to Existing Sign COLOR CHIPS
Freestanding Affixed to Building
For Affixed Signs:
Style of mounting fixture: Color:
Size of sign: Material:
Lettering: Style Color(s):
Please note sign placement on elevation(s)and attach full-color mockup(s)of proposed
sign(s) including artwork and colors.
For Freestanding Signs:
Style of signboard: Material:
Size: Color(s):
Lettering: Style Color(s):
Posts: Material Color(s):
Height to crossbar(not to exceed 6'): Single-faced: Double-faced:
Please note sign placement on plot plan and attach full-color mockup(s) of proposed
sign(s) including artwork and colors.
For All Signs:
Lighted: Yes No
Type/placement of lighting:
Screening of Lights:
Additional information:
1' awal m fXZ S /'�� Side t'd vis76/4/7
eel) dE 5e 19cls,
2-Sign
APPLICATION#:
Telephone(508)398-2231 Ext. 1292 Fax(508)398-0836 R j P
OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE
45-DAY TIMEFRAME
WAIVER
Application #:
Project Address: 140. 7 Pc ,e-. Dret oe
Application Received Date: // 6` 2ô0 3
45 Day Decision Deadline:
I/We, the undersigned owner, contractor, or agent, do hereby waive the
45-day timeframe for a determination on our application for a Certificate
of Appropriateness/Demolition/Exemption by the Old King's Highway
Historic District Committee for the following project:
Jew ? 56./.c /4-„,e-iS
Date: /A a 66/2 Signed: - f-e-e
Owner
Owner
,/),„7.(„paet‘
Contract/Agent
TOWN OF YARMOUTH
OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE
2023 MEETING SCHEDULE --Aar
TOWN OF YARMOUTH
OLD KIND'S HIGHWAY HISTORIC DISTRICT COMMITTEE
ABUTTERS' LIST
Applicant's (Owner) Name: e4-�
Property Address/Location: 19u e Cov--
Hearing Date: I I3/;--3
Notices must be sent to the Applicant and abutters (including owners of land on any
public or private street or way) who's property directly abuts or is across the street from
the Applicant Please provide the Assessor's Tax Map and Lot numbers only. The
OKH Office will send out notices using the addresses as they appear on the most recent
applicable tax list
Note Instructions for obtaining the abutters Map and Lot numbers can be found on the Old Kng's
Highway Department page on the Town webs!te wwNi arrnouth ma us
Map Number Lot Number
Applicant Information I 103 .5316,433
Abutter Information:
I L 3 16 563
143 ibg32-
fLf3 5 'l iba-3-1
3
Application :
82018
w a
143/ 33/ / /
MOORE KEVIN J • Please use this signature to certify this list of properties
MOORE RONNI A directlyabuttingand across the street from the parcel located at:
10 CROMWELL DR
YARMOUTH PORT,MA 02675 12 Dundee Dr., Yarmouth Port, MA 02675
Assessors Map 143, Lot 53
143/ 52/ / /
CORSI NICOLA A it
CORSI NATIA Andy MAchado, Director of Assessing
9 LIVERPOOL DR January 26, 2023
YARMOUTH PORT,MA 02675
143/ 53/ / /
PORTER SUSAN S
LOVE SHARON K
12 DUNDEE DR
YARMOUTH PORT,MA 02675
143/ 54/ / /
DIRICO DENNIS F
DIRICO KAREN E
26 DUNDEE DR
YARMOUTH PORT,MA 02675
143/ 58/ / /
MCCAFFREY DONNA E (LIFE EST)
15 DUNDEE DR
YARMOUTH PORT,MA 02675-1518
71t \23
143/ 59/ I / dvvt.1
QUINN CARROLL LEROY JR 1
QUINN LORIANNE
5 DUNDEE DR
YARMOUTH PORT MA 02675
143/ 51/ / /
CAMARA JUDITH A TR
THE JACAMARA REV TRUST
43 COLLINGWOOD DR
YARMOUTH PORT,MA 02675
1 i
,93_ 0r
1/17/23,2:42 PM about:blank
A.,
12 Dundee Drive
/1 ( ir- _i____ 11.43A8_ 4 I \\\ N,...,
1 i 1 I ; 1117 1 i• -.. 143.86,5 / *-----.41/ 143.90
li 1 143.65 I i I i t i s., ,
\ / 143.89
143 !461 i 143.67 I I \\ \ 143.86.4
//
i
----- ‘ i ,,) I \ \ / ---„,,
\ N-, 1
I .„.." 1 1 \143.86.6 \ \ _
, ----,._ i
-,,,,,,4,„
\\‘• ---- ' LIVElk-Pioor ' - I ille I
_ _DRIVE
1 n 143:-63 7, .,-- ,,,
i -,,' i
1431,72 I \ 'I ,) ''''''''''' 143.87 -----
1„ i I I 4 4 '
/,I.N 143.86,7\
, , --„„
---/ 1 i 143 52 / I N. \ ). /- 143.86.3 „/
.
/ '(.3, 1'1173 /' i\ i ,,,
', t .,. /
i I . / 4-44) '
143.59 1 I / , ''
/ '' 143.86.2/,'
; \ / ''.,, -.„„/ 144 . - .,
' ‘• ,-' 143.85 f /
' 143:-
143:50 .
113.58
, ' ,- „ -
fic,,--,6'.' 143.86.1
'., 143.33 - 14334 Co 14176
143.54 , *4. 4/6‘1;(1.:, .*,,143.41 41-13.77
14' 143.
1.32 95
,
,'
14357 1 '` ' Vw . '
•
/.4c,, ' 7,:z9 ,,/ lik,42 ,-'. - 14378
4,C,
,61- 1Z40 ..ii.. . -7'''•
'143.31 ,-'0' 14136 • 'Iv '.4
142 143.48 " / 1444;84 ,4;.../',01,kr('
1511A.C14/F
143.56 143.55 -, -, 143.37 , ,,, , ,' 14181. „
,11, -11.,
555_
1 ? •• , . , ' , •, ‘, t 1
: _.: .: 3:•I•
- ' -
•'t..'. . ,-, -•
t
1/1 about:blank
WES . November 30. 2022
• 300 Cranberry Highway
Orleans,MA 02653 Rt• it
T: JrWINDLLC
. PO Box 700
Brewster.MA 02631
i �1/4'4 ....�73 f "1 ` ` 888-997-8694
�1 nuri x).surrn vindlic.corn
Residential Solar Roof Mount System Proposal
To: Susan Porter
12 Dundee Drive
Yarmouthport. MA 02675
We propose to install a solar photovoltaic (PV)system at the above listed address to reduce annual
electrical costs by generating onsite electricity.
Sunwind recommends installing the system detailed below to optimize solar energy production:
Scope of Work
•Install a 10.5 kW(10,500 Watt)photovoltaic system using(28)LG 375 Watt or equal solar panels.
•Install Enphase IQ7A microinverters to convert solar panel DC power into AC.
•The system shall be installed on black Snap N'Rack aluminum racking.
•Install components for data monitoring via the existing internet connection.
•SMART meter socket and AC disconnect to be located on the exterior per utility company requirement.
•Install solar warning placards per code.
Installed Coss
We propose to install the solar photovoltaic system as outlined above for 1111010
Price is valid for thirty days from the date ofthis proposal.
Cast-Based Incentives(First Year)
Federal investment Tax Credit(30%of the installed cost) sper
MA Residential Renewable Energy Income Tax Credit S1,006
Total value of incentives WNW
Balance after incentives
Production-Based Incentives
Net Metering: Massachusetts laws allow for all solar energy facilities to be interconnected to the
electrical service provider. The excess energy produced by a net-metered facility is exported to
the electrical grid and system owners are credited for all energy exported at a value roughly equal
to the prevailing price per kWh.
SMART Program: The state of Massachusetts SMART(Solar Massachusetts Renewable Target)
program is designed to help customers reduce their electrical energy costs with an added incentive.
The SMART program pays you monthly via check for the power generated by your solar system at a
set rate per kWh produced,for a term of 10 years.
SyItem Details & Revenue
System DC Size: 10.5 kW Annual Energy Offset: 95%
System AC Size: 9.77 kW Annual Electric Consumption: 13.000 kWh
Est.Financial Gain Year 25: $96,344 Annual System Production: 12,285 kWh
Annual Revenue/Savings(First Year):
Net Metering Value: 12,285 kWh x $0.26/kWh= $3.194
SMART Revenue: 12.285 kWh x $0.035/kWh(cun-ent SMART rate)= $430
Total annual value of energy: Annual Net Metering+SMART Revenue= $3,624
Return on Investment:
Balance after first year savings and revenue:
Balance after cost-based Annual savings Balance after
incentives - &revenue = first year
- $3.624 =
Balace after cost-based Annual savings Simple ROI
incentives - and revenue =
53,624 = 6.1 Years
5100,000
$75,000
•
(13
S50,000
m
E
$25,000
c
d
$0
-S25,000
5 10 15 20 25
Year
This graph represents the data contained in the table on the following page.
Turnkey System:
'Conduct a site inspection,complete a written proposal and design drawings.
'Prepare HDC application and present to the board for approval of the project if required.
'Provide stamped engineered plans from MA licensed structural and electrical engineers as needed.
'Apply for building and electrical permits with the town inspectional services office.
•Submit the interconnection agreement with the utility company.
"Submit the SMART application with the MA Department of Energy Resources(D.O.E.R.).
"Upon issuance of the building permit we shall expedite materials to the site.
'Install and commission the system.
*Schedule building and electrical inspections.
"Submit close-out documents to the utility company for approval to install SMART meter.
'Upon receipt of"permission to operate"from utility-company we shall submit close-out documents to
D.O.E.R for final approval.
•Familiarize client with system monitoring and maintenance.
Installation:
•All work will be completed in accordance with Local. State and Federal building codes and accepted solar
installation practices.All work will be performed by licensed and/or properly trained personnel and shall be
performed in a manner consistent with the safety standards as required by OSHA and the Massachusetts
Department of Industrial Accidents.
Warranty:
•Sunwind.LLC shall warranty the installation(all parts and labor)of the solar system for 5 years from
the date of final inspection.
•The solar modules carry a manufacturer product&production warranty of 25 years.
•The inverter manufacturer provides a 25-year warranty.
•Sunwind's labor warranty only covers equipment inteenet connectivity issues for 60 days after the date of
final inspection. Service calls beyond this range will be charged an hourly service rate.
General Notes:
•Sunwind. LLC shall make evert effort to provide clients with the most up to date incentive information.
•Sunwind. LLC shall not be held liable for any change in the amount of incentives or energy attributes
estimated to be received.
•We encourage all clients to discuss the incentives with their accountant to determine current and future
tax liability.
Payment Schedule:
•15%due upon signing of this proposal.
•50%due upon receipt of the building permit and interconnection application approvals.
•25%due when the solar panels are installed.
•10%due upon completion of inspections by local building department.
1/We authorize Sun Wind, LLC to execute the work as described above,for which the undersigned
agrees to pay the amount stated and as agreed to in the terms herein.
Signature: Gt 1>rt G� / 'vr i Date: 4/30(2 C'7.,7_
Client/Owner: Susan Porter
7
Signature r"..''-..--7 ,� Date: //.— 3 r -004i3 a_
Contractor: Timothy S.Hol s,President of Sunwind LLC
System Layout
Proposed Solar Panel Layout
Dundee Dr
Suggest pruning
renmoz-ing trees in
the area between
garage and blue
• line to eliminate
shading...
20 solar panels on the garage roof
S panels on the rear of the main house
Total of 28 solar panels on roof
9 y `
All)k
n w
4 ' r , a a, -,.
" 3"- ��. - Asa"
s
` �' k -•. �" ram.,, s *. • .1 '
i
t '= eE t S•. ?
,,,{
r
a)
> t
•
•
o • _ r
Cl)
C
N .=f
s?"
tz_
p,}'.
a
- � >
J
44,
a
i
pax a
•
t tom. N i
` . 3 * r 3 d iLff . ' � - 4 qC t,'-a C
a y_
aW
3
.-,. ,r . '
xe
Cd
CaCV
s_
I
e ,Y.
0
x
t
b g. 4 5
g
"' -#
A
'zF__ - ✓ rt
* - € , �,
s `.' '�4y. _.
LG N ON® Black
ass
. .: •
LG375N1K-A6
375
The LG NeON'D 2 is LG's best selling solar module and one of the
most powerful and versatile modules on the market today.The cells
are designed to appear all-black at a distance,and the performance
warranty guarantees 90.6%of labeled power output at 25 years.
CL us
'VPs a„ *
Iq s"
**
EA
Enhanced Performance Warranty 25-Year Limited Product Warranty
LG NeONI"2 Black has an enhanced The NeOV 2 Black is covered by a 25-year
performance warranty.After 25 years, limited product warranty In addition,up to S450
LG NeON'"'2 Black is guaranteed at least of labor costs will be covered in the rare case
90.6%of initial performance that a module needs to be repaired or replaced
Solid Performance on Hot Days ;. Roof Aesthetics
LG NeON'°2 Black performs well on hot LG NeON®2 Black has been designed with
bays due to its low temperature coefficient aesthetics in mind using thinner wires that
appear ail black at a distance
Vlihnn you g0 solar, ask for the brand you can trust: 1.,G Solar
About LG Electronics USA,Inc
LG_ 1 ,. I cp rt is gT 4 ff g P' v g -lt-T 7. an - m6arned I_,
Life's Good
LG375N1 K-A6_AUS.indd 1 5/17/21 10:56 AM
1 I
•
L e Black ; "
LG375N1K-A6
,al Dot, E-__0'ic 1 r 5or (_'.:")
Cell Poop ties(Material/Type) Monccrysta r_7%-type Model LG375N1K-A6
Cell Maker • LG Maximum Power(Prnax) [W) 375
Cell Configuration 60 Cells(6 x l0) MPP Voltage(Vmpp) [!) 35"- -...
Number of Busbars -..._ -.. 1 PEA MPP Current(impp) [A] : 1045
Module Dimensions(Ix W x H) 1,740mm x 1,04 2rnm x 40 min Open Circuit Voltage(Von t 5%) VI 42.0- -
N/eighi ...._. :... _ - 18 6
kg
Short Great Current(Inn t5%) [A] I 1 00
Glass(Material) _ - Tempered Glass with AR_oanny Module Efficiency..... _ - Mil 2007
Backsheet(Color) _ _.. _ .. Black Power Tolerance [a) _-... 0--3
Frame(Material) ... Anodized Alum Mran *...-C(Standard Test Condition)irradiance 10001P/in).cell temperate:,25.0 AM 1 5
measurerner.s To1erence of ernax s 2%
Junction Box(Protection Degree) !P 6E with 3 Bypass Diodes
Cables(Length) 100mrn x PEA
Connector(Type/Maker) MC 4/MC _;_rd "iir,•:::',.
Operating Temperature [`C) -40 -35
Maxknun System Voltage _... N] 1,000)UL/.EC)
EC)6121 5-1/ 1,2 2016 E.C730- 2016, Maximum Series Fuse Rating [A] 20
JL61730,1 2017.JI .730-2 2017 Mechanical Test Load*(Front) [Pa/psi] 5,400
Certifications !SO 9001 1SO 14001,ISO 50001
Mechanical Test Load.(Rear) [Pa/psi) 4000
OHSAS 18001 "erased onlEC 61215-2 2016 Test Load-Design iced Safety Factor/1))
(_ <9n1_a y� �,
Sal.Mist Corrosion Test _ SEC 61701 2012 Severity 6 Oechanical T sr Loads 6,000Pa/5.400Pa based on I`CnC 61215.2905
Ammonia Corrosion Test _.. !EC 62716 2013
Module Fire Performance Type 2(UL 61730) ,,1:; ,,,.,,
Fire Rating Cias C(UL 790,!.LC/ORD C 1703)
_. ,. Number of Modules per per Pallet [EA) 25
Solar Module Product Warranty 25 Year limited
Number of Modules per 40 Container [EA] 650
Solar Module Output Warranty roar Waranty' - - 5°C
Number of Modules per 53'Container [EA.]
*rimp/oged 1"year 98 5%from 2 ti t ar-0 3324iyear d_,'n, 0 U_a!year 25
Packaging Box Dimensions(L x W x H) [inmi j 1,790 x 1,120 x 1,213
Packaging Box Dimensions(L x W x H) [in] 70.5 x 44 1 x 47.E
Packaging Box Orals Weight [kg 500
NMOT' _. _ — ['3] 42.t 3 _.. r'
Packaging Box Gross Weight [lb] 02
Pmax
[AFC] 035
Voc [54/C) -026
Ise [%/°C]. 0.03 },..
'N>v J )Jam rai M..Lle Operating erperaru.e) ..are 800 INkn.I Arbent ten pe-atu:e 20'C,
Wed speed 1 nest Spectrum AM 15
042 0 i:':,ixe or S,ep.Oral
=.,
Model LG375N I K-A6 sh y 40-_ ::.7
r
Maximum Power(Pneax) [W] 28 s x yv,n; ¢ — _
�—
2.
1
r
MPP Voltage(Vmpp) [V] 3dJ a I-1 i
MPP Current(impp) IA] ^a.33 -043 02 I I (i
Open Circuit Voltage(Von) [VI 39 5 _. - 1
Short Circuit Current(Ise) [A] 8B4 °Ida rgn:es
li
I]
iI
i
edw . - it � _,
wv -
Ll U
;� H
\\,. ,-- -
p
gok2ge[el
Electronics r Pio Product _)ons are suele t to change without:cece
5 Business t 1 A Au,S.pdf
Ln,n .
'Lite`S Good 6-_., 2021 Lc., 'E. . 5.. A.'..c.A11 rtehts.e7e".red
1
LG375N1K-A6_AUS.indd 2 5/17/21 10:56 AM
•
r •
§TOWN OF YARMOUTH
1146 Route 28, South Yarmouth, MA 02664
508-398-22311 ext.-1261 Fax 508-398-0836
Office of the Building Commissioner
BUILDING DEPARTMENT
DEMOLITION DEBRIS DISPOSAL AFFIDAVIT
Pursuant to M.G.L. Ch. 40, §54 and 780 CMR- Section 105.3.1. #4.
T hereby certify that the debris resulting from the proposed work/demolition to be
conducted at AZ.
Øude /9r, e
Work Address
be disposed of oat the following location: S 7 5 ex� f 0c ``t�
Is to p
Said disposal site shall be a licensed solid waste facility as defined by M.G.L.
Ch. 111, §150A.
//z
at
Signature ooplication e
Permit No.
s 4
•
November 30. 2022
300 Cranberry Highway
SUN'W'INDLLC
• PO Box 700
,, k ,.." Brewster, MA 02631
888-997-8694
www,sunwindllc.com
Residential Solar Rqof Mount System Proposal
To:Susan Porter
12 Dundee Drive
Yarmouthport,MA 02675
We propose to install a solar photovoltaic(PV)system at the above listed address to reduce annual
electrical costs by generating onsite electricity.
Sunwind recommends installing the system detailed below to optimiie solar energy production:
Scope of Work
•Install a 10.5 kW(10,500 Watt)photovoltaic system using(28)LG 375 Watt or equal solar panels.
•Install Enphase IQ7A microinverters to convert solar panel DC power into AC.
•The system shall be installed on black Snap N.Rack aluminum racking.
•Install components for data monitoring via the existing interne connection.
•SMART meter socket and AC disconnect to be located on the exterior per utility company requirement.
•Install solar warning placards per code.
Installed Cost
We propose to install the solar photovoltaic system as outlined above for S32„500
Price is valid for thirty days from the date of this proposal.
Cost-Based Incentives(First Year)
Federal Investment Tax Credit(30%of the installed cost) $9,750
MA Residential Renewable Energy Income Tax Credit $1,000
Total value of incentives $10,750
Balance after incentives $22,000
Production-Based Incentives
Net Metering: Massachusetts laws allow for all solar energy facilities to be interconnected to the
electrical service provider.The excess energy produced by a net-metered facility is exported to
the electrical grid and system owners are credited for all energy exported at a value roughly equal
to the prevailing price per kWh.
SMART Program: The state of Massachusetts SMART(Solar Massachusetts Renewable Target)
program is designed to help customers reduce their electrical energy costs with an added incentive.
The SMART program pays you monthly via check for the power generated by your solar system at a
set rate per kWh produced,for a term of 10 years.
v
r
System Details& Revenue
System DC Size: 10.5 kW Annual Energy Offset: 95%
System AC Size: 9.77 kW Annual Electric Consumption: 13,000 kWh
Est.Financial Gain Year 25: $96,344 Annual System Production: 12,285 kWh
Annual Revenue/Savings(First Year):
Net Metering Value: 12,285 kWh x$0.26/kWh= $3,194
SMART Revenue: 12,285 kWh x $0.035/kWh(current SMART rate)= $430
Total annual value of energy: Annual Net Metering+SMART Revenue= $3,624
Return on Investment:
Balance after first year savings and revenue:
Balance after cost-based Annual savings Balance after
incentives - &revenue = first year
$22,000 - $3,624 = $18,376
Balace after cost-based Annual savings Simple ROI
incentives -- and revenue
$22,000 - $3,624 = 6.1 Years
System Payback Graph
$100,000
$75,000
a)
co $50,000
m
ca
E
$25,000
co
$0
-$25,000
5 10 15 20 25
Year
This graph represents the data contained in the table on the following page.
Lifetime Savings/Revenue of Proposed System:
The revenue and savings are calculated using the SMART rate and estimated annual energy rate
increases over the 25 year life of the system. The SMART program is a 10 year incentive program for
all solar installed in Massachusetts. The insurance and maintenance expenses listed below are estimated
to show expenses incurred over the life of the system-they are not required payments.
Year Net metering SMART insurance Maintenance Balance
1 $3,194 $430 -$50 -$18,426
2 $3,290 $430 -$50 -$14,756
3 $3,389 $430 -$50 -$10,987
4 $3,490 $430 -$50 -$7,117
5 $3,595 $430 -$50 -$3,142
6 $3,703 $430 -S60 $931
7 $3,814 $430 -$60 $5,114
8 $3,928 $430 -$60 $9,413
9 $4,046 $430 -$60 $13,829
10 $4,168 $430 -$60 $18,367
11 $4,293 -$60 -$18O $22,419
12 $4,421 -$60 $26,781
13 $4,554 -$60 $31,275
14 $4,691 -$60 $35,905
15 $4,831 -$70 -$190 $40,477
16 $4,976 -$70 $45,383
17 $5,126 -$70 $50,438
18 $5,279 -$70 $55,648
19 $5,438 -$70 -$210 $60,806
20 $5,601 -$70 $66,336
21 $5,769 -$70 $72,035
22 $5,942 -$80 $77,897
23 $6,120 -$80 -$2 0 $83,708
24 $6,304 -$80 $89,931
25 $6,493 -$80 $96,344
Total $116,455 $4,300 -$1,600 -$810 $96,344
The savings and revenue shown above are calculated using data from The Massachusetts
Department of Energy Resources(D.O.E.R.)SMART program. For more detailed information on
the SMART program follow the link provided: www.mass.gov/info-details/solar-massachusetts-
renewable-target-smart-program
Y .r
h
Turnkey System:
•Conduct a site inspection,complete a written proposal and design drawings.
'Prepare HDC application and present to the board for approval of the project if required.
'Provide stamped engineered plans from MA licensed structural and electrical engineers as needed.
•Apply for building and electrical permits with the town inspectional services office.
•Submit the interconnection agreement with the utility company.
"Submit the SMART application with the MA Department of Energy Resources(D.O.E.R.).
"Upon issuance of the building permit we shall expedite materials to the site.
'Install and commission the system.
*Schedule building and electrical inspections.
'Submit close-out documents to the utility company for approval to install SMART meter.
"Upon receipt of"permission to operate"from utility company we shall submit close-out documents to
D.O.E.R for final approval.
'Familiarize client with system monitoring and maintenance.
Installation:
•All work will be completed in accordance with Local, State and Federal building codes and accepted solar
installation practices.All work will be performed by licensed and/or properly trained personnel and shall be
performed in a manner consistent with the safety standards as required by OSHA and the Massachusetts
Department of Industrial Accidents.
Warranty:
•Sunwind,LLC shall warranty the installation(all parts and labor)of the solar system for 5 years from
the date of final inspection.
•The solar modules carry a manufacturer product&production warranty of 25 years.
•The inverter manufacturer provides a 25-year warranty.
•Sunwind's labor warranty only covers equipment internet connectivity issues for 60 days after the date of
final inspection. Service calls beyond this range will be charged an hourly service rate.
General Notes:
•Sunwind,LLC shall make every effort to provide clients with the most up to date incentive information.
*Sunwind,LLC shall not be held liable for any change in the amount of incentives or energy attributes
estimated to be received.
•We encourage all clients to discuss the incentives with their accountant to determine current and future
tax liability.
Payment Schedule:
•15%due upon signing of this proposal.
•50%due upon receipt of the building permit and interconnection application approvals.
•25%due when the solar panels are installed.
•10%due upon completion of inspections by local building department.
I/We authorize SunWind, LLC to execute the work as described above,for which the undersigned
agrees to pay the amount stated and as agreed to in the terms herein.
Signature: )14,2 %- a vt.,. Date: /1 •30/Z e 7 2_
C1' n ner: Susan Porter /
ie t/Ow
Signatures .%/�_....J Date: //'— 30 -0Ze+�7 oZ
Contractor: Timothy S.Hot s,President of Sunwind LLC
f i \
J7s
structu ra
ENGINEERS
December 18, 2022
Timothy Holmes
PO Box 700
Brewster, MA 02631
Subject:Structural Certification Letter
Job Number: PZSE Portal #10021
Project Name: Porter Solar
Client PO:
Address: 12 Dundee Drive,Yarmouth, MA 02675
Attn.:To Whom It May Concern,
Re: Residential Flush-Mount Solar Photovoltaic Installation
PZSE's scope of work is limited to performing a structural evaluation of loading at the address above.After
review, PZSE certifies that the alteration to the existing structure by installation of the PV system meets the
requirements of the applicable codes and criteria shows below:
Design Criteria
• Applicable Codes: 780 CMR, ASCE 7-10 and NDS-15
• Ground Snow Load:30 lb/sqft
• Basic Wind Speed: 140 mph, Exposure Category C
• Existing Roof Dead Load: 7 lb/sqft
• Existing Roof Live Load:20 lb/sqft
The existing structure is adequate to support the PV alteration per Code Sections 402.3 and 402.4.
Residential PV Module Assembly
The PV module assembly including structural supporting components shall be installed in accordance with the
manufacturers specifications and meets or exceeds all requirements set forth by the referenced codes above.
Residential Installation Requirements
The PV system shall be mounted flush to the existing roof surface.The contractor shall notify PZSE of any signs of
damage to the roof framing prior to commencing the installation. PZSE shall then determine if the existing roof is
adequate to support the applied loads.The electrical engineering and waterproofing system shall be
addressed by others.
If you have any questions on the above,do not hesitate to call.
Prepared By: °F444
PZSE, Inc.-Structural Engineers
Roseville, CA (//,‘"if PA
ZACHER
ULK. Ni,
STRUCTURAL y
\ .1/4: , gMiAi ,
CIA\
0NA1 .
1478 Stone Point,Suite 190, Roseville, CA 95661
916.961.3960 T 916.961.3965 ; www.pzse.com
structu ra
December 19,2022 ENGINEERS
Sunwind LLC
PO Box 700
Brewster,MA,02631
Subject:Structural Certification for Installation of Solar Panels
Job Number:22-16856
Client:Porter Colar-010021
Address: 12 Dundee Dr,Yarmouth,MA 02675
Attn.:To Whom It May Concern
PZSE's scope of work is limited to performing a structural evaluation of loading at the address above.After review, PZSE certifies
that the alteration to the existing structure by installation of the PV system meets the requirements of the applicable codes and
criteria shown below:
Design Criteria:
• Applicable Codes=780 CMR,ASCE 7-10,and NDS-15
• Ground Snow Load=30 psf;Roof Snow Load=25 psf ARRAY 1&2
• Basic Wind Speed=140 mph Exposure Category B
• Existing Roof Dead Load:ARRAY 1&2=10 psf
• Existing Roof Live Load: 17.9 psf
The existing structure is adequate to support the PV alteration per 2015 IEBC§402.3&402.4.
PV System Assembly
The PV module assembly including all structural supporting components shall be installed in accordance with the manufacturers
specifications and meet or exceed all requirements set forth by the referenced codes above.
Installation Requirements
The PV system shall be mounted flush to the existing roof surface.The contractor shall notify PZSE of any signs of damage to the
roof framing prior to commencing the installation.PZSE shall then determine if the existing roof is adequate to support the
applied loads.The electrical engineering and system waterproofing shall be addressed by others.
If you have any questions on the above,do not hesitate to call.
Prepared By: 1 PAS ,UL � ,
ZACHER •
PZSE,Inc.-Structural Engineers • STRUCTURAL
Roseville,CA Q.SQ1QQ„
t
SSK7NAL '
1478 Stone Point Drive, Suite 190, Roseville, CA 95661
916.961.3960 916.961.3965 www.pzse.corn
f
• •
System Layout
Proposed Solar Panel Layout
Dundee Dr
Dr
Suggest pruning
removing trees in
the area between
garage and blue
' " line to elirnir+nte
shading...
20 solar panels on the garage roof
8 panels on the rear of the main house
Total of 28 solar panels on roof
s M
n
t
no 1 rac ,
Solar Mounting Solutions
Ultra Rail
..._ ,.. ....,..._.. ......_ ..,....,,.....____,... ....... ..__............, ,. ,,...
1.a
r
tot }
ML , E
ML
,'`r
4gs0000e
Composition Roof Attachment Tile Repl. .. t nt Roof Attachment Fiat Tile Roof A • hment
Roof attachment kit for composition Roof attachment kit for fiat,S.and Roof attachment kit for flat tile
Ingle roofs including L foot. W tile roofs Including base, riser.tile roofs including tile hook and
u _• ella lag screw,flashing.an• replacement flashing.L foot,and hardware
hardw.1 hardware
Mt.. �F. ML
--------1-' illr'llei-- — °
Metal ' - Attachment Seam Clamp • . :chment Ultra Rail Mounting Hardware
Roof attachment kit for fiat metal Roof attachment for standing seam Hardware kit for attaching Ultra Rail
roofs including metal roof base.L metal roofs including seam clamp.L to any roof attachment that uses an
foot,and hardware foot,and hardware L foot or other slotted mount that
accepts 5/l6"hardware
.�,, -,
Mt,Gfte 1 ML,Gf8
r ML,Gig
a
Fps
f 411111%. ").-.-----
UR-40 Rail Ultra Rail Splice I h;...iii...-----;:i .'1 -
���
UR-4splice componento rail for Ultra Rail roof mount Rail Mid Clamp
Including two Top-down module mid clamp
racking system splice halves and hardware
Including clamp and hardware
7 U.JL Listing Legend:
ML-Evaluated for Mechanical LoaidIrg
5 ='s;'e-Evaluated for Grounding/Bond I
... i.
. ,
sf4!Pmlftifr,Ft:
5 .
WISMaiff4 N.1.,t4W ,-,51,
,..,....11,11N1114114
0 0
1 lae 11A,10'''III
NI.L:CV"'git''.1!114111
4111441*.loati ML 40,
-- - lb *.: ''''<":-.•' ""' .* " -...„-44'- .,'4,,.........„..,- _,...,.. .7,.,
.,---..•-,Nrs,"."7 . -
111110111/4;;;e----
4%1 rilio. .
Adjustable End Clamp Universal End Clamp Universal Wire Clamp
Top-down module end clamp Bottom-mount module end clamp Wire management component used
including clamp and hardware including damp and hardware to secure conductors between rails
--,5,
,..e . , '--------- G/B <0.,.. ...„.•
,,
),...>,kt .. .
.-- •..,
- ,....*-- - -•.-:',..,...._.,--..,4-:...*--
- .
ze.5, ...
),.-1 :IN111*1 _.. 11114111!
.,.. ---._ -... -- ,.• ,
' illiA0iM1/4:1111111;kik.....*S11111111.,000000/04114*
...,,•,'
.'., '.'.-;',.•
Wire Retention Clip MLPE Rail Attachment Kit MLPE Frame Attachment Kit
Wire management component used Ralf attachment for module level Module frame attachment for
to secure conductors In rails power electronics like microinverters module level power electronics Nke
and optimizers mlcrolnverters and optimizers
,z::,L,..r -,;,...,• ,i:,,,,t I,I;-14:-)i 1 :.:,,,,'1 r-1
0 (S)
4141%11411%%%lllirIIIIIIIIII41111111ib
, • - ' . GA
. ..,,,.
G/B
4.--
+
I
" kith ''''
ir
ill ;' -1. tillikok i
'--,•7 j
11111010400 i
SnapNrack Ground Lug lisco Lay-In Lug -GBL-4DBT UR-40 Rail End Cap
Plastic end cap for UR-40 Rail
7 '..IL.. Listinc_l Le'cierld:
ML-Evaluated for Mech:3nIcal Loacilrg
6 Gi 6,- Pialuated for GrourdIngleorld Wog
, ':'• *
wpritiat
O Hammer or Stud Finder • Roof Marking Crayon 4) DrUl with 3/16"Mot Drill Bit • Roof Sealant
41 Torque Wrench • Socket Wrench • I/2"Socket
1',.,-'l-i,:,1-:-
0 (I)SnapNrack Comp Umbrella Flashing r
41110: 50
-, 9)
o (1)SnapNrack Umbrella Lag screw 5 IP 0
O (1)SnapNrack Umbrella L Foot
O (I)SnapNrack Ultra Mount (Tapped)
ft44`-t's:,,,,,,,,,F:,04.-,
0 4•Fro,400,
• (1)SnapNrack Ultra Mount(Thru-Hole)
4%. Ntfafr
0 (I)SnapNrack Ultra Mount Spring
0 (1)SnapNrack Ultra Mount Spring Cage 0
ff4
0 (1) S/16"-18 X 2-1/4"SS HCS Bolt .•• 4%.
00
? A rpi ic at 1 0 I-) Note:
Install on composItkon shingle roofs.
L5 ask .
10111°111
Llij 9IY i
k.....*11 I.
IIIII
4.1.1k
I
:..._
.7-
:7-
----
_.
,-
.......
.7-
::-
LS
Dimensioned L Foot
Dimensioned L Foot Assembly
1,
� a
.0.41
i',.,,f.'".,,(1', '',.!.,-?r,...if 1,',,,--:,i'-•
• Level • String Lino or Spare Rail • Pitch Meter • Torque Wrench
O Socket Wrench • 1/2"Socket
r'-1-,;14,-:, ••,1 -V:k.A1.4:- •1 - ::r1;;;!.-- H•,,.. -'-'1!•), ! ,'--r,--1 ,!• ,J :--',-:-;-;-
• SnapNrack Ultra Rail
or
• SnapNrack Ultra Pall Splice
• Pro-Installed SnapNrack Roof Attachments
......","..........„, ",---------'
(i.Foot Mount,Tile Replacement,etc.)
0 4(iii• - ",
mt ..."'
--,, I
161:„... ..40.,.
0 SnapNrack L Foot Extension
0
....---„,---- .....---..-••
' MP'
..------f--1 ...--'1.-
..
i ......
I• IIIS\1\ <111>' '
N.)s-•-^''''''
UR-40 Rail Pronto
11
0°1.141.°
----."--" .0 •... '
1 .... '4,-
It
L Foot Extension
Ultra Rail Spike
25
r -
. . . -
St141
0 Torque Wrench 4. Socket Wrench • 1/2"Socket
—gab -----
.*P- ......r---'
0 Pre-Installed SnapNrack Roof Attachments
',"dP°
• Pre-Installed SnapNrack Rails
O SnapNrack Mid Clamp Assemblies
• SnapNrack End Clamp Assemblies
O PV Modules 1141111111000
mowdomean,,,,e4w
mosaatekmataft
0 (1)5/16"-18 SS HCS Bolt 0 (1) 5/16"-1B SS HCS Bolt
0 (i)5/16"SS Split Lock Washer 0 (1) 5/16" SS Spit Lock Washer
O (1) SnapNrack Mlci Clamp 0 (1)SnapNrack Adjustable End Clamp Top
0 (1)SnapNrack SS Mid Clamp Spring 0 (1) SnapNrack Adjustable End Clamp Bottom
0 (1)5/16"-10 SnapNrack Channel Nut
., so
ii&. -,OS* lluoir
• "%b.
,%•1444. ,14,......10„...,TS'1"1111;i10>e' i.1.0...-41111,Ss_ _.,,,a143".40
41)...
*... EN ....
40;
- III
41104,---- .
,,---<- sly. 40
. 10.
10448%1***43410, , .
,,,-,
liiik ,.
lir
O _..44-ofr: .
4100h.
40000000000,p 0
.10 0 0 (1)5/16"-18 x 1-1/2"sS HCS Boit et
•
0 (1)5116"X 3/41 SS Flat Washer
O (1)SnapNrack Universal Wedge
O (1)SnapNrack Universal Wave
29
f J
LG N ON®2 Black
LG375N 1 K-A6
375W
The LG NeON®2 is LG's best selling solar module and one of the
most powerful and versatile modules on the market today.The cells
are designed to appear all-black at a distance,and the performance
warranty guarantees 90.6%of labeled power output at 25 years.
C ' US
7 5
A p �.r._
*** blade in rsasmr
***USA/
*** ��
Features
Enhanced Performance Warranty ® 25-Year Limited Product Warranty
"'" "` LG NeON®2 Black has an enhanced
The NeON®2 Black is covered by a 25-year
performance warranty.After 25 years, limited product warranty.In addition,up to$450
LG NeON®2 Black is guaranteed at least of labor costs will be covered in the rare case
90.6%of initial performance that a module needs to be repaired or replaced.
ti Solid Performance on Hot Days Roof Aesthetics
—' LG NeON®2 Black performs well on hot
days due to its low temperature coefficient. _J LG NeON®2 Black has been designed with
aesthetics in mind using thinner wires that
appear all black at a distance.
When you go solar, ask for the brand you can trust: LG Solar
About LG Electronics USA,Inc.
LG Electronics is a global leader in electronic products m the clean energy markets by offering solar pV panels and energy storage systems.The company first embarked on a solar
energy source research program in 19B5,supported by LG Groups vast experience in the semi-conductor,LCD,chemistry and materials industnes.In 2010,LG Solar successfully 0 LG
released its first MonoX®series to the market,which is now available in 32 countries.The NeON (previous Monoke NeON),NeONe2,NeONe2 Biiacial won the"Intersolar
AWARD"in 2013,2015 and 201b,which demonstrates LG's leadership and innovation in the solar industry.
Life's Good
LG375N1K-A6_AUS.indd 1
5/17/21 10:56 AM
n w
LG NeON4'2 Btack gusA=
LG375N1K-A6
General Data_ Electrical Properties(STC*)
Cell Properties(Material/Type) Monocrystalline/N-type Model
__. LG375N7K-A6
Cell Maker -.. aximwe Power LG M I [W] ' 375
Cell Configuration 60 Cells(6 x 10) MPP Voltage(VraPP) [v] _.- 3s.9 -_-.
Number of Busters ._..-. _..
12EA MPP Current(Mnpp) [A] 10.45
Module Dimensions(L x W x H) 1,740mm x 1,042mm x 40 mm Open Circuit Voltage(Voc±5%) [V] 42.0
Weight --- 186k9 Short Omit Current(Hc es%) [A] 1100 ..
Glass(Material) Tempered Glass with AR coating Module Efficiency [%] 2007
Backstreet(Color) _... Black .___
__. , Power Tolerance [56] 0^4-3
Frame(Matelot) Anodized Aluminium `SIC(Standard Test Condition):irradiance 1000 W/m',cell temperature 25°C,AM 1.5
Junction Box(Protection ------ - Measurement Tolerance of Pmax,t 3%
Degree) •
IP 68 with 3 Bypass Diodes
Cables(length). 1,100mm x 2EA __-._......
Connector Rye/ter) ' MCa/Mc
Operating Conditions
---------
Operating Temperature I [C] -40-+85
Certifications and Warranty Madman System Voltage M 1,000(UVIEC)
IEC 61215-1/-1-1/2:2016,IEC 61730-1/2:2016, Maximus Series Fuse Rating I [A] 20
UL 61730-1:2017,UL 61730.2 _ _
2017 MecharkalTest Load`Front
Certifications' -.. ISO 4001,150 14001 Iso 50001 ..: _- ( _..-� lPa/P� _-. s aoo
Mechanical Test Loade(Rear) I [Px/psf] 4,000
OHSA518001 ... _.____. _._._._.... __.__._..._..
_._ `Based on IEC 612152,2016(TestLoad-Design Load x Safety Factor(1.5))
Salt Mist Corrosion Test IEC 617012012 Severity 6 Mechanical Test Loads6000Pa/5,400Pa based on IEC 61 21 5 200 5
Ammonia CorosionTest i IEC 62716:2013
Marble Fire Performance Type 2(UL61730) packaging Configuration
Fire Rating _ Class C(UL.790,ULC/ORD C 1703) --
.. _- Number of Modules per Pallet i [EA] 25
d Solar Mole Pact W mite arranty 25 Year lid
Number of Modules per 40'Container • [EA] I 650
Solar Module Output Warranty Linear Warranty` Number of Modules r 53'Container _. - ........-
`Improved:1"year98.5%,from224th year:033%/year down,90.6%at year25 -- [EA] 850
Packaging Box Dimensions(L x WxH) ! [mm] . 1,790 x 1,120 x 1,213
Temperature Characteristics Packaging Box Dimensions(L x W x H) j [in] 70.5 x 44.1 x 47.8
xD - - __.
NMOT• [°C) --_.— 42±3 _Packaging Box Gross Weight .... 500
Pines � 1 -0.35 __.. _....._-. -Packaging Boot Gross Weight_ _ [lb] ,._. _._... 1,102
[%PC] ; -0.26
Isc [31 . 003 Dimensions(mm/inch)
.NMOT(Nominal Module Operating Temperature):Irradiance 800 W/m',Ambient temperature 20°C,
Wind speed 1 m/s,Spectrum AM 1.5
1042.0/41.0(Srte of Short Side)
Electrical Properties(NMOT)
1002.0/39A(Distance between Grounding 8 Mounting Holes)
Model •
16375N1K-A6 --- ---
_..._ 40.0/1.57
Maximum Power(Prtw) I [WI 281 1750/69
16-60e3.0/03x0.1
MPP Voltage(Vmpp) M I 337 --_.. Drain Holes n
._(hop) ! [A] ': 8.33 _.-...... e-04.3/0.2
MPP Current hn (-) (*)
.._ _._ _- -. ...._ Grounding Holes ° Junction Box
Open Circuit Voltage(Voc) I
[ 39.5 a an.x 12.0/ 0.s
r Short Circuit Current(lac) [A 8.84
oundng Holes
I_V Curves g
— 1100/43.3 I a -.
Cable Length 6 c
12.0--
000W
V 9
00 �Z" 3
800W n
ac -
600W
a
60
ao
gs
zo i N
au
,Tsryi oa
0.0 5.i. 10.0 li0 20D 25.0 30.0 35.0 a09 45.0
Voltage M ..
LG LG Electronics USA,Inc. Product specifications are subject to change without notice.
Solar0Business lbr os Drive
2000 Mil
0
Lincolnshire,IL 60069 051721
Life's Good 0 2021 LG Electronics USA,Inc.All rights reserved.
LG375N1K-A6_AUS.indd 2
5/17/21 10:56 AM
V`
•
«uqyf p�..Y F }�y
Enphase °�i rolnver e s
Enphase The high-powered smart grid-ready
Enphase IQ 7A Micro'' dramatically simplifies the
IQ 7A IVI icroinverter installation process while achieving the highest
system efficiency for systems with 60-cell and
72-cell modules.
Part of the Enphase IQ System,the IQ 7A Micro
integrates with the Enphase IQ Envoy'M, Enphase IQ
Batterytm',and the Enphase Enlighten'"" monitoring
and analysis software.
The IQ Series Microinverters extend the reliability
standards set forth by previous generations and
undergo over a million hours of power-on testing,
enabling Enphase to provide an industry-leading
warranty of up to 25 years.
High Power
• Peak output power 366 VA @ 240 VAC and 295 VA @ 208 VAC
Easy to Install
• Lightweight and simple
• Faster installation with improved,lighter two-wire cabling
• Built-in rapid shutdown compliant(NEC 2014&2017)
Efficient and Reliable
• Optimized for high powered 60-cell and 72-cell modules
• Highest CEC efficiency of 97%
• More than a million hours of testing
cuo—
• Class II double-insulated enclosure
147A • UL listed
M Smart Grid Ready
• Complies with advanced grid support,voltage and frequency ride-
through requirements
• Envoy and Internet connection required
• Configurable for varying grid profiles
• Meets CA Rule 21 (UL 1741-SA)
0
To learn more about Enphase offerings,visit enphase.com e EN PHAS E...
Y
•
Enphase IQ 7A Microinverter
INPUT(DC) IQ7A-72-2-US
Commonly used module pairings' 295 W-460 W+
Module compatibility 60-cell,66-cell,and 72-cell PV modules
Maximum input DC voltage 58 V
Power point tracking voltage range2 18 V-58 V
Min/Max start voltage 33 V/58 V
Max DC short circuit current(module Isc)3 15 A
Overvoltage class DC port II
DC port backfeed current 0 A
PV array configuration 1 x 1 ungrounded array;No additional DC side protection required;
AC side protection requires max 20A per branch circuit
OUTPUT(AC) @ 240 VAC @ 208 VAC
Peak output power 366 VA 295 VA
Maximum continuous output power 349 VA 290 VA
Nominal(L-L)voltage/range' 240 V/211-264 V 208 V/183-229 V
Maximum continuous output current 1.45 A(240 VAC) 1.39 A(208 VAC)
Nominal frequency 60 Hz
Extended frequency range 47-68 Hz
AC short circuit fault current over 3 cycles 5.8 Arms
Maximum units per 20 A(L-L)branch circuits 11 (240 VAC) 11 (208 VAC)
Overvoltage class AC port Ill
AC port backfeed current 18 mA
Power factor setting 1.0
Power factor(adjustable) 0.85 leading... 0.85 lagging
EFFICIENCY @240 VAC @208 VAC
CEC weighted efficiency 97.0% 96.5%
MECHANICAL
Ambient temperature range -40°C to+60°Cw
Relative humidity range 4%to 100%(condensing)
Connector type:DC(IQ7A-72-2-US) MC4
Dimensions(HxWxD) 212 mm x 175 mm x 30.2 mm(without bracket)
Weight 1.08 kg(2.38 Ibs)
Cooling Natural convection-No fans
Approved for wet locations Yes
Pollution degree PD3
Enclosure Class II double-insulated,corrosion resistant polymeric enclosure
Environmental category/UV exposure rating NEMA Type 6/outdoor
FEATURES
Communication Power Line Communication(PLC)
Monitoring Enlighten Manager and MyEnlighten monitoring options
Compatible with Enphase IQ Envoy
Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break
disconnect required by NEC 690.
Compliance CA Rule 21 (UL 1741-SA)
UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B,
CAN/CSA-C22.2 NO.107.1-01
This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and
NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC
and DC conductors,when installed according manufacturer's instructions.
1.No enforced DC/AC ratio.See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility.
2.CEC peak power tracking voltage range is 38 V to 43 V.
3.Maximum continuous input DC current is 10.2A.
4,Voltage range can be extended beyond nominal if required by the utility.
5.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area.
To learn more about Enphase offerings,visit enphase.com
A 2020 Enphase Energy All rights reserved.Enphase,the Enphase logo,Enphase IQ 7A,Enphase IQ Battery,Enphase Enlighten,Enphase IQ
Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change.
2020-06-16
E N P H A S E
F .