Loading...
HomeMy WebLinkAboutBLD-23-002471 , , ata_; /e ii /e22 RECEIVED, NOV 012022 ONE & TWO FAMILY ONLY- BUILDING PERMIT BUILDING DEPARTMErT ' Town of Yarmouth Building Department 1146 Route 28,South Yarmouth,MA 02664-4492 508-398-2231 ext. 1261 Fax 508-398-0836 SI Massachusetts State Building Code,780 Building Permit Application To Construct, Repair, Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number:6 L) -02 3 -b ag-y 1i) Date Applied: /1(-).--7,jz � —� Building fficial(Print Name) Signature Date SECTION 1:SITE INFORMATION 1.1 Property Address: 1.2 Assessors Ma &Parcel Numbers 45 moor j n 1oq. �3 1.1 a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards i Rear Yard Required I Provided Required i Provided Required Provided 1.6 Water Supply: (Evi.G.L c.40,154) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: i Public 0 Private 0 Zone: Outside Flood Zone? — I Municipal 0 On site disposal system 0 Check if yes0 f j SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Re,cord: . �wv in son t-h oat... Vat-rno u he‘Ps o,10�o Name(Print) City,State,ZIP Li 5 mooein o Un 5o640 0614 lam i,; No.and Street J Telephone mail Address SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction 0 Existing Building 0 I Owner-Occupied 0 I Repairs(s) 0 Alteration(s) CI [Addition 0 I Demolition 0 Accessory Bldg. 0 Number of Units Other 0 Specify: ___ Brief Description of Proposed Work'-: i & or an. �(n e rj — -o and e Pv 5-15 1' LY1..QJ- Lk- 9 a_s vnt' SECTION 4:ESTIMATED CONSTRUCTION COSTS. Item Estimated Costs: ' Official Use Only (Labor and Materials) 1.Building $ -7 1_w , 1. Building Permit Fee:S %SD Indicate how fee is determined: 1 �. 0 Standard City/Town Application Fee 2.Electrical $ l b, V e 0 0 Total Project Cost3(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ I 4.Mechanical (HVAC) $ List: 0241 07.234 0,9116 5 2' 5.Mechanical (Fire $ . Suppression) Total All Fees:$ Check No. Check Amount: Cash Amount: 6.Total Project Cost: $q 9 aaq.6V ❑Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) b' `O` ea e[' p l I a. VN f License Number Expiration Date Name of CSL Holder List CSL Type(see below) V No.and q 55n'my n 5+ot eti S/t In B va d Type Descriptionur I,n mA- .-1 Q U Unrestricted(Buildings up to 35,000 cu.ft.)_ CitylTown,State,ZTP Iv!1� i) R Restricted l�&2 Family Dwelling M Masonry RC I Rootlrrg Covering WS Window and Sidine • �I !�7�J�� SF Solid Fuel Burning Appliances [) ��l 1XYrL'>tile� �'•iwn i Insulation Telephone Email addres .Li)", D Demolition _ 5.2 Registered Home Improvement/� Contraactoor(BIC) 1 80 'a V O . C J 1v V t s ` €.�V\ t.7 d' « HIC Registration Number Expirat on Date IjI CompanyName SRe istrant N es,^1 eiva ' No.and Street V ��"''' ail dd n [�.+ ; City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ❑ No ❑ SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize to act on my behalf,in all matters relative to work authorized by this building permit application. COtti`ram"' Print Ovmer's Name(Electronic Signature) Date • SECTION 7b: OWNERI OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. el Print Ovmer's or.' .horizcd Agent's Name(El onic Signature) --L iz Datc NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will nor have access to the arbitration program or guaranty fund under M.G.L.c. 142A. Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/'oaths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" �... SUNRINC-02 LWANG2 ACOtRO CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDD/YYYY) kt....----' 8/31/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER License#0C36861 CONTACT NAME: Walter Tanner Alliant Insurance Services,Inc. PHONE FAX 560 Mission St 6th Fl (A/C,No,Ext): (NC,No): San Francisco,CA 94105 ' ss:Walter.Tanner@alliant.com INSURERS)AFFORDING COVERAGE NAIC S INSURER A:Evanston Insurance Company 35378 INSURED INSURER B:James River Insurance Company 12203 1 Sunrun Installation Services,Inc INSURER C:American Zurich Insurance Company 40142 775 Fiero Lane,Suite 200 Ph#805-540-7643 INSURER D: San Luis Obispo,CA 93401 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POUCY EFF POUCY EXP LIMITS LTR INSD WVD QAM/DDIYYYY) (MM/DD/YYYYI A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2,000,000 CLAIMS-MADE X OCCUR MKLV5ENV103749 10/1/2022 10/1/2023 DAMAGETORENTED 1,000,000 PREMISES(Ea oceurrenc� $ MED EXP(Any one person) $ 5,000 PERSONAL 8 ADV INJURY $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 X POLICY X JECT LOC PRODUCTS-COMP/OP AGG $ 2,000,000 X OTHER:Retention:$100,000 Per Project Agg $ 5,000,000 AUTOMOBILE LIABILITY (Ea COMBINE LIMIT $ I ANY AUTO BODILY INJURY(Per person) $_ OWNED SCHEDULED _ AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ HIRED NON-OWNED PROPERTY DAMAGE AUTOS ONLY , AUTOS ONLY (Per accident) $ $ B UMBRELLA LIAB X' OCCUR EACH OCCURRENCE $ 4,000,000 X EXCESS LAB CLAIMS-MADE 001072261 10/1/2021 10/1/2022 AGGREGATE $ 4,000,000 DED RETENTION$ I _ $ C WORKERS COMPENSATION X STATUTE OTH- ER AND EMPLOYERS'LIABILITY Y N WC614287601 10/1/2022 10/1/2023 1,000,000 ANY PROPRIETOR/PARTNER/EXECUTIVE N NIA E.L.EACH ACCIDENT $ FFICER/MEn BN EXCLUDED? 1,000,000 E.L.DISEASE-EA EMPLOYEE $ If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Workers'Compensation Policy WC614287601 Deductible:$1,000,000. Re: Permitting within jurisdiction. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of Yarmouth THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. 1146 Route 28 South Yarmouth,MA 02664-4492 AUTHORIZED REPRESENTATIVE ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD 101 Commonwealth of Massachusetts Construction Supervisor owrsion or Protesswnai re Unresticted -Buildings of any use group which contain apart,apart,of Bu�5in9 tp Standards and StandarUs less than 35,000 cubic feet(991 cubic meters)of enclosed it1Sps visor fie' CS-040622 bites_08101 2023 STEPHEN A FELLY 16 PARISWAYROAD r STONEHAM 02100 ) r Fafure to possess a current edition of the MtassachustllIS Commissioner ., !: _, /:,; State Budding Code is cause for revocation of this WINS& For i nfom.t on about this license Call(617)7273200 or visit wwwmass.govldpl THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs and Business Regulation 1000 Washington Sre t-Suite 710 Boston,Massachusetts 02118 Home Improvement Registration r;% Type Supplement Card SUNRUN INSTALLATION SERVICES INC. 14 RegBtratlon 180120 21 WORLDS FAIR OR 1� - Expiration. 10/13/2024 SOMERSET.NJ 08873 11.1 Update Address and Return Card. THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs&Business Regulation Regftretron.afd for llldieMual use only before the HOME IMPROVEMENT CONTRACTOR expiration date.Pissed return to: TYPE:Sopp6ernent Card Office of Consumer Anoka and Business Regulation g*yMlpypnEasthatian 1000 Washington Street•Suds 710 180120 10/13/7024 Boston,MA 02118 SUNRl1N INSTALLATION 3 4VICFS INC. 1-f' STEPHEN KELLY • '� 225 BUSH STREET l !�ea,..�(�„4 SUITE 1400 SAN FRANCISCO,CA 94104 Undersecretary t valid without gnatu re Stephen A Kelly 695 Myles Standish Blvd Taunton MA 02780 TEL:978-793-7881 Email: eastmapermits@sunrun.com §TOWN OF YAIaMOUTH 1146 Route 28, South Yarmouth, MA 02664 508-398-22311 ext. 1261 Fax 508-398-0836 Office of the Building Commissioner BUILDING DEPARTMENT DEMOLITION DEBRIS DISPOSAL AFFIDAVIT Pursuant to M.G.L. Ch. 40, §54 and 780 CMR- Section 105.3.1. #4. I hereby certify that the debris resulting from the proposed work/demolition to be conducted at l--1 m car 1 ( ( Work A ress Is to be disposed of oat the following location: 5 my(1)3 6 fit,► 1c? slue) 7W-i-0fl Said disposal site shall be a licensed solid waste facility as defined by M.G.L. Ch. 111, §150A. \Of 3 \e) )--,r) Signa re of Applicatio Dat Permit No. 1 ne commonweaun of lvlassacnusens Department of Industrial Accidents _ - s11 Office of Investigations im.=.-- ,,,_ Lafayette City Center _ 'S 2 Avenue de Lafayette, Boston, MA 02111-1750 -4,4 '�� y� www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Sunrun Installation Services Address: 225 Bush St STE 1400 City/State/Zip: San Francisco CA 94104 Phone #: Are you an employer? Check the appropriate box: Type of project(required): 1.® I am a employer with 50 4. ❑ I am a general contractor and I employees (full and/or part-time).* have hired the sub-contractors 6. El New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have 8. ❑ Demolition working for me in any capacity. employees and have workers' 9. ❑ Building addition [No workers' comp. insurance comp. insurance. required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.] t c. 152, §1(4),and we have no employees. [No workers' 13.1M Other e f& comp. insurance required.] *My applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. $Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: American Zurich Insurance Company Policy#or Self-ins. Lic. #:WC614287601 Expiration Date: 10/01/2023 Job Site Address: Lt S ry1 I City/State/Zip: �ft [l�G(,1- Attach a copyof the workers' com ensa ' n policy declaration page(showing the policy number and expiration date). P Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjuty that the information provided above is true and correct Si ature: e Date: 43_1_1_ .— Phone#: Official use only. Do not write in this area, to be completed by city or town official. City or Town: Permit/License # Issuing Authority(check one): 10Board of Health 20 Building Department 30City/Town Clerk 4.0 Electrical Inspector 5Elumbing Inspector 6.0Other Contact Person: Phone#: Information and Instructions Massachusetts General Laws chapter 152 requires all employers to provide workers' compensation for their employees. Pursuant to this statute, an employee is defined as"...every person in the service of another under any contract of hire, express or implied, oral or written." An employer is defined as"an individual,partnership, association, corporation or other legal entity, or any two or more of the foregoing engaged in a joint enterprise, and including the legal representatives of a deceased employer, or the receiver or trustee of an individual,partnership, association or other legal entity, employing employees. However the owner of a dwelling house having not more than three apartments and who resides therein, or the occupant of the dwelling house of another who employs persons to do maintenance, construction or repair work on such dwelling house or on the grounds or building appurtenant thereto shall not because of such employment be deemed to be an employer." MGL chapter 152, §25C(6)also states that"every state or local licensing agency shall withhold the issuance or renewal of a license or permit to operate a business or to construct buildings in the commonwealth for any applicant who has not produced acceptable evidence of compliance with the insurance coverage required." Additionally, MGL chapter 152, §25C(7) states"Neither the commonwealth nor any of its political subdivisions shall enter into any contract for the performance of public work until acceptable evidence of compliance with the insurance requirements of this chapter have been presented to the contracting authority." Applicants Please fill out the workers' compensation affidavit completely, by checking the boxes that apply to your situation and, if necessary, supply sub-contractor(s) name(s), address(es) and phone number(s) along with their certificate(s) of insurance. Limited Liability Companies (LLC) or Limited Liability Partnerships (LLP)with no employees other than the members or partners, are not required to carry workers' compensation insurance. If an LLC or LLP does have employees, a policy is required. Be advised that this affidavit may be submitted to the Department of Industrial Accidents for confirmation of insurance coverage. Also be sure to sign and date the affidavit. The affidavit should be returned to the city or town that the application for the permit or license is being requested, not the Department of Industrial Accidents. Should you have any questions regarding the law or if you are required to obtain a workers' compensation policy, please call the Department at the number listed below. Self-insured companies should enter their self-insurance license number on the appropriate line. City or Town Officials Please be sure that the affidavit is complete and printed legibly. The Department has provided a space at the bottom of the affidavit for you to fill out in the event the Office of Investigations has to contact you regarding the applicant. Please be sure to fill in the permit/license number which will be used as a reference number. In addition, an applicant that must submit multiple permit/license applications in any given year, need only submit one affidavit indicating current policy information (if necessary) and under"Job Site Address"the applicant should write "all locations in (city or town)."A copy of the affidavit that has been officially stamped or marked by the city or town may be provided to the applicant as proof that a valid affidavit is on file for future permits or licenses. A new affidavit must be filled out each year. Where a home owner or citizen is obtaining a license or permit not related to any business or commercial venture (i.e. a dog license or permit to burn leaves etc.) said person is NOT required to complete this affidavit. The Office of Investigations would like to thank you in advance for your cooperation and should you have any questions, please do not hesitate to give us a call. The Department's address, telephone and fax number: The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations Lafayette City Center, 2 Avenue de Lafayette Boston, MA 02111-1750 Tel. (617) 727-4900 or 1-877-MASSAFE Fax (617) 727-7749 Revised 7-2019 www macc unv/clia gS EV projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.com 10/31/2022 RE:Structural Certification for Installation of Residential Solar KEVIN DONAHUE:45 MOORING LN,YARMOUTH,MA,02664 Attn:To Whom It May Concern This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report,the roof is made of Composite shingle roofing over roof plywood supported by 2X10 Rafters at 16 inches.The slope of the roof was approximated to be 24 degrees,43 degrees and 45 degrees. After review and based on our structural capacity calculation,the existing roof framing has been determined to be adequate to support the imposed loads without structural upgrades. Contractor shall verify that existing framing is consistent with the described above before install. Should they find any discrepancies, a written approval from SEOR is mandatory before proceeding with install. Capacity calculations were done in accordance with applicable building codes. Design Criteria Code 2015 IRC(ASCE 7-10)-CMR 780 9th =d Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 140 mph PV Dead Load DPV 3 psf Exposure C Roof Live Load Lr 20 psf Ground Snow S 30 psf If you have any questions on the above, please do not hesitate to call. STRUCT . oNL `�n, Sincerely, �� ssc o -S' VINCENT Gr Vincent Mwumvaneza, P.E. If MWUMVANEZA CIVIL EV Engineering, LLC Na. 2 projects@evengineersnet.com y; co ��,�•i. ERG�F http://www.evengineersnet.com �• ioNAIEN 1/1 =- EV projects@evengineersnet.com 276-220-00,54 ENGINEERS http://www.evengineersnet.com Structural Letter for PV Installation 10/31/2022 Job Address: 45 MOORING LN YARMOUTH,MA,02664 Job Name: KEVIN DONAHUE Job Number: 221031 KD Scope of Work This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Table of Content Sheet 1 Cover 2 Attachment checks 3 Snow and Roof Framing Check 4 Seismic Check and Scope of work Engineering Calculations Summary Code 2015 IRC(ASCE 7-10)-CMR 780 9th Ed Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 30 psf Wind Load (component and Cladding) V 140 mph Exposure C References NDS for Wood Construction STRUCT . ONL MASs4 Sincerely, �� VINCENT -LP o MWUMVANEZA CIVIL Vincent Mwumvaneza, P.E. q !Na% 2 EV Engineering, LLC ;j.;'.�' E0,o\�<``e projects@evengineersnet.com •� ONALENG http://www.evengineersnet.com 1/1 MIWY EV projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.com Wind Load Cont. Risk Category= II ASCE 7-10 Table 1.5-1 Wind Speed (3s gust),V= 140 mph ASCE 7-10 Figure 26.5-1A Roughness = C ASCE 7-10 Sec 26.7.2 Exposure= C ASCE 7-10 Sec 26.7.3 Topographic Factor, KZT= 1.30 ASCE 7-10 Sec 26.8.2 Pitch = 24.0 Degrees Adjustment Factor,]t= ASCE 7-10 Figure 30.5-1 a = 3.60 ft ASCE 7-10 Figure 30.5-1 Where a: 10%of least horizontal dimension or 0.4h,whichever is smaller,but not less than 4%of least horizontal dimension or 3ft(0.9m) Uplift(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= -29.3 -41.3 -65.1 Figure 30.5-1 Pnet=0.6 x X x KZT x Pnet30)= 21.29 29.99 47.28 Equation 30.5-1 Downpressure(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= 15.7 15.7 15.7 Figure 30.5-1 Pnet=0.6 x A x KZT x Pnet30)= 11.41 11.41 11.41 Equation 30.5-1 Rafter Attachments: 0.6D+0.6W(CD=1.6) Connection Check Attachement max. spacing= 5.3 ft 5/16" Lag Screw Withdrawal Value= 205 lbs/in Lag Screw Penetration 2.5 in Allowable Capacity= 512.5 0.6D+0.6W Dpv+0.6W Zone Trib Width Area(ft) Uplift(lbs) Down(lbs) 1 5.3 14.6 284.0 210.0 2 5.3 14.6 410.8 210.0 3 3 8.3 375.2 118.9 Max= 410.8 < 512.5 CONNECTION IS OK 1. Pv seismic dead weight is negligible to result in significant seismic uplift,therefore the wind uplift governs 2. Embedment is measured from the top of the framirg member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. 1/1 - EV projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.com Vertical Load Resisting System Design Roof Framing Rafters Pg= 30 psf ASCE 7-10, Section 7.2 Pf= 21 psf Ce= 0.9 ASCE 7-10,Table 7-2 Pfmin. = 25.0 psf Ct = 1.1 ASCE 7-10,Table 7-3 Ps= 25 psf 25.6 plf Is = 1.0 ASCE 7-10,Table 1.5-1 CS 0.767 Max Length, L= 12.42 ft Tributary Width,WT= 16 in Dr= 10 psf 13.33 plf PvDL= 3 psf 4 plf Load Case: DL+0.6W Pnet+PPVcos(6)+PD[= 32.5 plf Max Moment, Mu= 465 lb-ft Conservatively Pv max Shear 210.0 lbs Max Shear,V„=wL/2+Pv Point Load = 318 lbs Load Case: DL+0.75(0.6W+S)) 0.75(Pnet+Ps)+ PPVcos(6)+PDL= 48 plf MdoW = 680 lb-ft Mallowable =Sx x Fb' (wind)= 3157 lb-ft > 680 lb-ft OK Load Case: DL+S Ps+ PpVcos(6)+PDL= 43 plf MdoWn= 609 lb-ft Mallowable =Sx x Fb' (wind)= 2269 lb-ft > 609 lb-ft OK Max Shear,Vu=wL/2+Pv Point Load = 318 lbs Member Capacity SPF#1/#2 2X10 Design Value CL CF C; Cr Adjusted Value Fb= 875 psi 1.0 1.1 1.0 1.15 1107 psi Fv= 135 psi N/A N/A 1.0 N/A 135 psi E = 1400000 psi N/A N/A 1.0 N/A 1400000 psi Depth, d = 9.25 in Width, b = 1.5 in Cross-Sectonal Area,A= 13.875 in2 Moment of Inertia, l .= 98.9316 in" Section Modulus, Sxx= 21.3906 in' Allowable Moment, Mail= Fb'SXX= 1973.1 lb-ft DCR=M /Mali= 0.26 < 1 Satisfactory Allowable Shear,Vail= 2/3F,'A= 1248.8 lb DCR=Vu/Vaii = 0.25 < 1 Satisfactory 1/1 EV projects@evengineersnet.com 276-220-0064 moom ENGINEERS http://www.evengineersnet.com Siesmic Loads Check Roof Dead Load 10 psf %or Roof with Pv 37% Dpv and Racking 3 psf Averarage Total Dead Load 11.1 psf Increase in Dead Load 4.5% OK The increase in seismic Dead weight as a result of the solar system is less than 10%of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on information in pictures and a drawing set titled PV plans- KEVIN DONAHUE.The analysis was according to applicable building codes, professional engineering and design experience, opinions and judgments.The calculations produced for this structure's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. 1/1 DocuSign Envelope ID:B5B0FA9D-F192-4758-9F6C-8628C446EB31 Sunrun BrightSave TM Agreement Kevin Donahue 45 Mooring Ln, Yarmouth, MA, 02664 Take Control of Your Electric Bill SO 25 Years $201 $0 .200 Deposit due Agreement Term Length Monthly Bill for Year Year 1 Cost per kWh Today (3.5% annual increase One (plus taxes, if applicable; (excluding upfront in monthly bill) includes $7.50 discount for payment, if any) Auto-Pay enrollment) WE'VE GOT YOU COVERED WITH OUR WORRY-FREE SERVICE C;) Vir r=> We provide hassle-free We monitor the system We warrant, insure, Selling your home? design, permitting, and to ensure it runs maintain and repair We guarantee the buyer installation. properly. the system. We will qualify to assume also provide a 10- your agreement. year roof warranty. A SOLAR SYSTEM DESIGN FOR YOUR HOME You get a 12.78 kW DC Solar System With 35 Solar Panels and 2 Inverter(s) Which will produce an es t 12,057 kWh in its first year And offset approx.120% of your current, estimated electricity usage YOUR SALES REPRESENTATIVE: Alicia Macomber alicia.macomber@sunrun.com (7 1) 254-3139 DocuSign Envelope ID:B5B0FA9D-F192-4758-9F6C-8628C446EB31 By signing below, you acknowledge that you have reviewed and received a complete copy of the Agreement without any blanks. Such Agreement shall be the complete understanding between the Parties. SUNRUN I T,466411,Q. N SERVICES INC. Signatur 6° 73"/..4 `�` F9A27AE333064FF_. Print Name: Collyn Balderama Date: 10/13/2022 Title: prnjPct operations Federal Employer Identification Number: 26-2841711 IF YOU CHOOSE TO PAY BY CHECK, MAKE CHECKS OUT TO SUNRUN INC. NEVER MAKE A CHECK OUT TO A SALES REPRESENTATIVE. OUR SALES REPRESENTATIVES ARE NOT AUTHORIZED TO RECEIVE CHECKS IN THEIR OWN NAMES. YOU MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF THE TENTH EFFECTIVE DATE. PLEASE REVIEW THE ATTACHED NOTICES OF CANCELLATION FOR AN EXPLANATION OF THIS RIGHT. Customer ,PIrr m account Holder Secondary Account Holder (Optional) '-868ig1'# t Kevin Donahue Signature 10/13/2022 Date Print Name Email Address*: kevinmckaydonahue@gmail .com Mailing Address: 45 Mooring ' .' Yarmouth, MA 02664 Phone: (508) 400-5749 *Email addresses will be used by Sunrun for official correspondence, such as sending monthly bills or other invoices. Sales Consultant By signing be/ow/acknow/edge that/am Sunrun accredited, that/presented this agreement according to c11111614h1i Code of Conduct and that/obtained the homeowner's signature on this agreement. aqua At.a�b itk►r 6 tira11n Alicia Macomber Print Name 1946192592 Sunrun ID number Sunrun Installation Services Inc. 1225 Bush Street, Suite 1400, San Francisco, CA 94104 1 888.GO.SOLAR I HIC 180120 Contract Version: 202001 V1 Generation Date: 10/13/2022 Proposal ID: PK4A1 K44V19K-H Version 2020Q1 V1 21 SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:12425W DC,10000W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), SOLAR MODULES •MODULES:(35)LONGI GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SE SERVICE ENTRANCE y PV-1.0 COVER SHEET LTD:LR4-60HPH-355M INSTRUCTIONS. 1 PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. SE10000H-USSN MP MAIN PANEL o o PV-3.0 LAYOUT •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV 4.0 ELECTRICAL SEE DETAIL SNR-DC-00436 SNR MOUNT •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP• SUB-PANEL PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. SNR MOUNT&SKIRT •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER FLUSH ATTIC VENT MODULES,ARE CLASS A FIRE RATED. PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC I AC DISCONNECT(S) SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC •11.25 AMPS MODULE SHORT CIRCUIT CURRENT. Q DC DISCONNECT(S) FIRE SETBACKS •17.57 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. CB IQ COMBINER BOX HARDSCAPE •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INTERIOR EQUIPMENT —PL— PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L J SHOWN AS DASHED SCALE NTS A AMPERE s u n r u n AC ALTERNATING CURRENT AFC! ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION DC DIRECT CURRENT #180120 (E) EXISTING 695 MALES STANDISH BLVD,TAUNTON.MA.D27l0.1131 _-.. _ ESS ENERGY STORAGE SYSTEM PHONED FABU EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC KEVIN DONAHUE MSP MAIN SERVICE PANEL 45 MOORING LN,YARMOUTH, (N) NEW MA,02664 E.:,'.ste' NTS NOT TO SCALE ((7.4) OC ON CENTER TEL.(508)400-5749 DeM'�s ,;__ PRE-FAB PREFABRICATED APN:YARM-000102-000013 PSF POUNDS PER SQUARE FOOT 45 MOCsI 1 (L PV PHOTOVOLTAIC PROJECT NUMBER: South i tl1 3' t RSD RAPID SHUTDOWN DEVICE .{ DONA TL TYPICAL MERLESS DESIGNER: (415)580-6920 ex3 TYP TYPICAL h8t '+Cn V VOLTS SUMAIR KHAN �1E W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET • • REV:Al 10/31/2022 PAGE PV-1.0 ARRAY TRUE MAG PV AREA SITE PLAN DETAIL-SCALE=1/16"=1'-0" SITE PLAN -SCALE=1/128"=1'-0" PITCH AZIM AZIM (SQFT) AR-01 45' 147° 161' 235.3 itZ IV AR-02 45' 147' 161' 78.4 AR-03 43° 237° 251' 254.9 AR-04 24° 57° 71° 117.7 SE (N)ARRAY AR-04 i (N)ARRAY AR-03 a(N)ARRAY AR-02 ,,, � AC °o #0 C 0. INV PM 1,_-1 ,,, �2 ,,, % (E)GATE i , E RESIDENCE AS 4,, sunrun (N)ARRAY AR-01 LMJ \V, #180120 0 885 MY ES STANDISH BLVD,TAINTON,MA,071110-7331 PHONE 0 FAX 0 CUSTOMER RESIDENCE: KEVIN DONAHUE 45 MOORING LN,YARMOUTH, MA,02664 TEL.(508)400-5749 APN:YARM-000102-000013 PROJECT NUMBER: 223R-045DONA DESIGNER: (415)580-6920 ex3 SUMAIR KHAN SHEET SITE PLAN REV:Al 10/31/2022 PAGE PV-2.O ROOF INFO I FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF Name Type Height Type Span Spacing Detail OC Spacing OverhangOC Spacing OverhangConfiguration P 9 P 9 P 9 SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X10 RAFTERS 11'-0" 16" COMP,SEE DETAIL SNR-DC-00436 5-4" 2'-1" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREWS: AR-02 COMP SHINGLE-RLU 1-Story 2X10 RAFTERS 8'_3" 16^ RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 5/16":2.5"MIN EMBEDMENT DETAIL SNR-DC-00436 STRUCTURAL NOTES: RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE • INSTALLERS SHALL NOTIFY AR-03 COMP SHINGLE-RLU 1-Story 2X10 RAFTERS 4'-3" 16" DETAIL SNR-DC-00436 5-4" 2'-1" 4'-0" 2'-0" STAGGERED ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES AR-04 COMP SHINGLE-RLU 1-Story 2X10 RAFTERS 12'-5" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED OBSERVED PRIOR TO DETAIL SNR-DC-00436 PROCEEDING W/ D1-AR-01-SCALE:1/8"=1'-0" D2-AR-02-SCALE:1/8"=1'-0" INSTALLATION. • IF ARRAY(EXCLUDING SKIRT) AZIM:147° AZIM:147° IS WITHIN 12"BOUNDARY PITCH:45° PITCH:45° REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS), 7" 23'-3" -------- -------- 8' THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG 6" 11'-7" 6'-10" • REDUCED WITHIN THE 12" 1'-6" BOUNDARY REGION ONLY AS -8 FOLLOWS: MIN _ 1'6" ° ••ALLOWABLE ATTACHMENT INIZINs SPACING INDICATED ON �� _ = PLANS TO BE REDUCED BY MI 0�1 " 6'-10" 50% 1 •• ALLOWABLE OVERHANG MI MI • • • INDICATED PLANS TO BE 1/5TH OF ALLOWABLE WABLE • 4' ATTACHMENT SPACING I INDICATED ON PLANS 5'-3" STRUCT C, ONL 1H OFAtis 1'-11'} ��, sr ��oMWUMVANEZA wN s u n r u n CIVIL N. 2 D3-AR-03-SCALE:1/8"=1'-0" D4-AR-04-SCALE:1/8"=1'-0" y;%aS,o �4e AZIM:237° ----29'-1"--- ---- 4'-1" AZIM:57° •• ONALVl #180120 PITCH:43° 2,-5. PITCH:24° css MYLESs.A"os s,VD,,ao"TON MA o:" 3 15'-10" -11'-7" 3'-10"{- PHONE 1,-6" I P.0 �--o — 0 0 0 0 0 5'4"TYP, I'S" CUSTOMER RESIDENCE: KEVIN DONAHUE 6'-10" o ❑ 0 a 3 c ❑ 45 MOORING LN,YARMOUTH, 10'-4" MA,02664 -,--_--- n r n O 0 ❑ ❑ ❑ 10'-4" TEL.(508)400-5749 NM APN:YARM-000102-000013 n n n n n _..-__ I 5'4"TYP PROJECT NUMBER: 13' t • • ._ 223R-045DONA 10'4" 4'9" DESIGNER: (415)580-6920 ex3 SUMAIR KHAN ' SHEET LAYOUT • REV:Al 10/31/2022 8'-8" 17'-5" } SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE OMETER#: NOTE:TOTAL PV BACKFEED=53A EVERSOURCE 2371109 USED FOR INTERCONNECTION UTILITY CALCULATIONS GRID SUPPLY SIDE TAP I 4 (N)LOCKABLE I EXISTING 200A BLADE TYPE (N)MA SMART SOLAREDGE TECHNOLOGIES: MAIN BREAKER FUSED AC UTILITY DISCONNECT REVENUE SE10000H-USSN 1 METER 10000 WATT INVERTER JUNCTION BOX PV MODULES �� 3 3 2 OR EQUIVALENT 1 LONGI GREEN ENERGY TECHNOLOGY EXISTING �-- 200A MAIN a�, _ O ,T — «�� _ - O/// CO LTD:LR4-60HPH-355M PANEL (35)MODULES OPTIMIZERS FACILITY 60A FUSES - I I (1)SERIES OF(12)OPTIMIZERS LOADS FACILITY ODO BV SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT (1)SERIES OF(12)OPTIMIZERS D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN (1)SERIES OF(11)OPTIMIZERS 3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT SOLAREDGE POWER OPTIMIZERS 120/240VAC CONNECTS TO TOP LUGS- P401 (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (6)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (6)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n 3 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 695 MYLES STANDISH BLVD,TAUNTON,MA 02 7 6 0-13 31 PHONED FAX CUSTOMER RESIDENCE: KEVIN DONAHUE 45 MOORING LN,YARMOUTH, MA,02664 MODULE CHARACTERISTICS P401 OPTIMIZER CHARACTERISTICS: TEL (508)400-5749 LONGI GREEN ENERGY APN:YARM-000102-000013 MIN INPUT VOLTAGE: 8 VDC TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: LR4-60HPH-355M: 355 W MAX INPUT ISC: 11.75 ADC 223R-045DONA OPEN CIRCUIT VOLTAGE: 40.3 V MAX OUTPUT CURRENT: 15 ADC MAX POWER VOLTAGE: 33.8 V DESIGNER: (415)580-6920 ex3 SHORT CIRCUIT CURRENT: 11.25 A SYSTEM CHARACTERISTICS-INVERTER 1 SUMAIR KHAN SYSTEM SIZE: 12425 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 12 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:Al 10/31/2022 SYSTEM OPERATING CURRENT: 31.06 A SYSTEM SHORT CIRCUIT CURRENT: 45A PAGE PV-4.0 WARN I N G INVERTER 1 NOTES AND SPECIFICATIONS: SIGNS AND LELS SHALL MEET THEPHOTOVOLTAIC DC DISCONNECT •1110.211(B),UNLESS SPECIFIC NSTRUCTIONSIREMENTS ARE REQUIRED BY SECOF THE NECTION 690,OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE: 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS,COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:890.13(B) WARNING: PHOTOVOLTAIC WARNING POWER SOURCE LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(DX2),IFC 2012: SYSTEM 605.11.1.4 LABEL LOCATION: CAUTION : UTILITY SERVICE METER AND MAIN SERVICE PANEL. NEC 2020: PER�E(S): DNIG RAPID SHUTDOWN SWITCH WARNI MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM i tit DO NOT RELOCATE THIS SOLAR PANELS ON ROOF a� OVERCURRENT DEVICE LABEL LOCATION: • INSTALLED WITHIN 3'OF RAPID SHUT DOWN LABEL LOCATION: SWITCH PER CODE(S):NEC 2020,690.56(C)(2),IFC sun r ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3 OCPD(IF APPLICABLE). ■I __� PER CODE(S):NEC 2020: 4"705.12(B)(3)(2) MAIN PANEL (INT) AWARNING SOLAR PV SYSTEM EQUIPPED #180120 PHOTOVOLTAIC SYSTEM WITH RAPID SHUTDOWN PHONE0MID i 551pND1$HOiVnTAuN'oN,Ma.o"tl0113i COMBINER PANEL di Call `A,p DO NOT ADD LOADS - CUSTOMER RESIDENCE: KEVIN DONAHUE LABEL LOCATION: 45 MOORING LN,YARMOUTH, PHOTOVOLTAIC AC COMBINER(IF IMA,02664 APPLICABLE). TURN RAPID SHUTDOWN INVERTER (EXT) FUSED AC All& PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) DISCONNECT TEL (508)400-5749 SWITCH TO THE"OFF" POSITION TO SHUT DOWN PV PRODUCTION APN:YARM-000102-000013 PV SYSTEM DISCONNECT 1 PV SYSTEM AND REDUCE PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT: 42 AMPS SHOCK HAZARD IN THE METER 223R-045DONA ARRAY. Mill -- SERVICE ENTRANCE OPERATING AC VOLTAGE: 240 VAC ARRAY. , -- SERVICE ENTRANCE DESIGNER: (415)5806920ex3 LABEL LOCATION: 45 MOORING LN, YARMOUTH, MA, 02664 SUMAIR KHAN AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. -- ---. ---- SHEET PER CODE(S):NEC 2020:690.54 LABEL LOCATION: PER CODE(S):NEC 2020:705.10,710.10 S IGNAG E ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:Al 10/31/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0 SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:12425W DC,10000W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), — SOLAR MODULES •MODULES:(35)LONGI GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SE SERVICE ENTRANCE PV-1.0 COVER SHEET LTD:LR4-60HPH-355M INSTRUCTIONS. r— PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. SE10000H-USSN MP MAIN PANEL 0 • a PV-3.0 LAYOUT •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV-4.0 ELECTRICAL SEE DETAIL SNR-DC-00436 0 0 " 0•PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SUB-PANEL SNR MOUNT PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. SNR MOUNT&SKIRT •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER CHIMNEY _ •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER FLUSH ATTIC VENT MODULES,ARE CLASS A FIRE RATED. PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). I AC I AC DISCONNECT(S) SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC •11.25 AMPS MODULE SHORT CIRCUIT CURRENT. I--•I DC DISCONNECT(S) FIRE SETBACKS •17.57 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. CB IQ COMBINER BOX HARDSCAPE •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INTERIOR EQUIPMENT —PL— PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATIONL J SHOWN AS DASHED SCALE:NTS A PERE AC 1ALTERNATING CURRENT s u n r u n AFC' ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION DC DIRECT CURRENT #180120 (E) EXISTING BAD MYLES ST.WOISH BLVD,TAUNTON,MA,02780-7331 ESS ENERGY STORAGE SYSTEM PHONE F.0 EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC KEVIN DONAHUE MSP MAIN SERVICE PANEL 45 MOORING LN,YARMOUTH, (N) NEW MA,02664 NTS NOT TO SCALE OC ON CENTER TEL.(508)400-5749 D•&0",, PREFAB PREFABRICATED APN:YARM-000102-000013 PSF POUNDS PER SQUARE FOOT PROJECT NUMBER: _ �: PV PHOTOVOLTAIC 223R-045DONA South YtR??U�l M•- RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS DESIGNER: (415)580-6920 ex3 =� TYP TYPICAL k3rw c' V VOLTS SUMAIR KHAN W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET REV:Al 10/31/2022 PAGE PV-1.0 ARRAY TRUE MAG PV AREA SITE PLAN DETAIL-SCALE=1/16"=1'-0" SITE PLAN -SCALE■1/128"-1'-0" PITCH AZIM AZIM (SOFT) AR-01 45' 147' 161' 235.3 It, AR-02 45' 147' 161' 78.4 AR-03 43' 237' 251' 254.9 AR-04 24' 57' 71' 117.7 S E (N)ARRAY AR-04 (N)ARRAY AR-03-- (N)ARRAY AR-02 P. 41111111.1111i y ao : Os a' INV 91nc140 ',,' o� t 2 *014111011, ,,,, C G< GATE (E)RESIDE NCE sunrun (N)ARRAY AR-01 LMJ #180120 SSS MYLES STANDISH BLVO,TAUNTON,MA,027567331 PHONED #14" CUSTOMER RESIDENCE: KEVIN DONAHUE 45 MOORING LN,YARMOUTH, MA,02664 TEL.(508)400-5749 APN:YARM-000102-000013 PROJECT NUMBER: 223R-045DONA DESIGNER: (415)580-6920 ex3 SUMAIR KHAN SHEET SITE PLAN REV:Al 10/31/2022 PAGE PV-2.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height T Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF 9 Type Detail OC Spacing Overhang OC Spacing Overhang Configuration Span Spacing SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X10 RAFTERS 11'-0" 16" COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREWS: AR-02 COMP SHINGLE-RLU 1-Story 2X10 RAFTERS 8'-3" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 5/16":2.5"MIN EMBEDMENT DETAIL SNR-DC-00436 STRUCTURAL NOTES: RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE •• INSTALLERS SHALL NOTIFY AR-03 COMP SHINGLE-RLU 1-Story 2X10 RAFTERS 4'-3" 16" DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES AR-04 COMP SHINGLE-RLU 1-Story 2X10 RAFTERS 12'-5" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED OBSERVED PRIOR TO DETAIL SNR-DC-00436 PROCEEDING W/ INSTALLATION. D1-AR-01-SCALE:1/8"=1'-0" D2-AR-02-SCALE:1/8"=1'-0" • IF ARRAY(EXCLUDING SKIRT) AZIM:147° AZIM:147° IS WITHIN 12"BOUNDARY PITCH:45° PITCH:45° REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS), T }k-- 23'-3" { 8" THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG 6" 11'-7" 6'-10" • REDUCED WITHIN THE 12" 1'-6" BOUNDARY REGION ONLY AS -13 -El- — a FOLLOWS: _ 1-6" 43 $ •• ALLOWABLE ATTACHMENT SPACING INDICATED ON 5-0 _'TYP PLANS TO BE REDUCED BY 10'-4" 6'-10" 50% •• ALLOWABLE OVERHANG INDICATED ON PLANS TO BE k 5'-0"TYP}- 1/5TH OF ALLOWABLE n 1 6. ,,. q ATTACHMENT SPACING INDICATED ON PLANS 5'-3" STRUCT _..._.". ONL 1H OF ALr Isunrun VINCENT cv, MWUMVANEZA N CIVIL N.. 2 D3-AR-03-SCALE:1/8"=1'-0" D4-AR-04-SCALE:1/8"=V-0" '•n: .."pt9 ��Q AZIM:237° 29'-1" -- 4'-1" - AZIM:57° '''. 'ONALEN�'N� #180120 PITCH:43° ) 2'-5. PITCH:24° WS MYLESsrwaSHBLVD,rwNTON,MA,Onen»1 15'-10" 11'-7" 3'-10" PHONED 1'-0• FAX 0 LEI- CUSTOMER RESIDENCE: 5-0• 1 6" KEVIN DONAHUE 6'-10" 45 MOORING LN,YARMOUTH, 10%4' MA,02664 .4- ------ - - _1111111:.111..=_ 10'-4" TEL.(508)400-5749 _ APN:YARM-000102-000013 1 -� PROJECT NUMBER: ° � 223R-045DONA 3 1 DESIGNER: (415)580-6920 ex3 10 4' 4'-9' SUMAIR KHAN SHEET LAYOUT 9• REV:Al 10/31/2022 r-- 17'-5" SEE SITE PLAN FOR NORTH ARROW PAGE PV-3•O 120/240 VAC SINGLE PHASE SERVICE M O METER#: NOTE:TOTAL PV BACKFEED=53A EVERSOURCE2371109 USED FOR INTERCONNECTION UTILITY CALCULATIONS GRID SUPPLY SIDE TAP I ,4 (N)LOCKABLE ( I EXISTING 200E BLADE TYPE (N)MA SMART MAIN BREAKER FUSED AC UTILITY SOLAREDGE TECHNOLOGIES: t DISCONNECT REVENUE SE10000H-USSN METER 10000 WATT INVERTER JUNCTION BOX PV MODULES "----N EXISTING 3 2 OR EQUIVALENT 1 LONGI GREEN ENERGY TECHNOLOGY EXISTING / CO LR4-6OHPH-355M 200E MAIN o,�, O `� _ �/. —� -Q/' (35)MODULES �� PANEL --- OPTIMIZERS LTD: WIRED IN: FACILITY 60A FUSES . I I (1)SERIES OF(12)OPTIMIZERS LOADS EAGARy GROUND SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT (1)SERIES OF(12)OPTIMIZERS D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN (1)SERIES OF(11)OPTIMIZERS 3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT SOLAREDGE POWER OPTIMIZERS 120/240VAC CONNECTS TO TOP LUGS- P401 (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (6)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (6)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 S u n r u n 3 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 695 MILES STANDISH FILVO,TAUNTON,MA,02 710-7 331 PHONED F.0 CUSTOMER RESIDENCE: KEVIN DONAHUE 45 MOORING LN,YARMOUTH, MA,02664 MODULE CHARACTERISTICS TEL.(508)400-5749 P401 OPTIMIZER CHARACTERISTICS: LONGI GREEN ENERGY MIN INPUT VOLTAGE: 8 VDC APN:YARM-000102-000013 TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: LR4-60HPH-355M: 355 W MAX INPUT ISC: 11.75 ADC 223R-045DONA OPEN CIRCUIT VOLTAGE: 40.3 V MAX POWER VOLTAGE: 33.8 V MAX OUTPUT CURRENT: 15 ADC DESIGNER: (415)580-6920 ex3 SHORT CIRCUIT CURRENT: 11.25 A SUMAIR KHAN SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM SIZE: 12425 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 12 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:Al 10/31/2022 SYSTEM OPERATING CURRENT: 31.06 A SYSTEM SHORT CIRCUIT CURRENT: 45 A PAGE PV-4.0 /"WARN I N G INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE: 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS,COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(B) WARNING: PHOTOVOLTAIC AWARNING POWER SOURCE LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. _-- AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(D)(2),IFC 2012: SYSTEM 605.11.1.4 LABEL LOCATION: CAUTION : UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S):NEC 2020:705.12(C) RAPID SHUTDOWN SWITCH AWARNING MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM `fil� DO NOT RELOCATE THIS —SOLAR PANELS ON ROOF OVERCURRENT DEVICE LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN L LOCATION: SWITCH012: PER CODE(S)::NEC 2.5.3 890.56(CH21.IFC s u n r u n ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3 OCPD(IF APPLICABLE). PER CODE(S):NEC 2020: 705.12(e'(3'WARNING a I- MAIN PANEL (INT) SOLAR PV SYSTEM EQUIPPED t #180120 SAS MYLES STANDISH BLVD,TAUNTON,MA 027e04331 PH COMBINER IPANEL C EM WITH RAPID SHUTDOWN CUS PHONE FAX 0 DO NOT ADD LOADS T � CUSTOMER RESIDENCE: 1 KEVIN DONAHUE LABEL LOCATION: a 45 MOORING LN,YARMOUTH, PHOTOVOLTAIC AC COMBINER(IF MA,02664 APPLICABLE). 3" TURN RAPID SHUTDOWN INVERTER (EXT)— FUSED AC PER CODE(S):NEC 2020:705.12(D)(2X3Xc) Aak SWITCH TO THE"OFF" DISCONNECT TEL.(508)400.5749 POSITION TO SHUT DOWN —PV PRODUCTION APN:YARM-000102-000013 F PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE PROJECT NUMBER: SHOCK HAZARD IN THE METER 223R-045DONA MAXIMUM AC OPERATING CURRENT: 42 AMPS NOMINAL OPERATING AC VOLTAGE: 240 VAC ARRAY. SERVICE ENTRANCE DESIGNER: (415)580-6920 ex3 LABEL LOCATION: 45 MOORING LN, YARMOUTH, MA, 02664 $UMAIRKHAN AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. - - - - - - SHEET PER CODE(S):NEC 2020:690.54 LABEL LOCATION: PER CODE(S):NEC 2020:705.10,710.10 SIGNAGE ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS __ ARE CONNECTED. REV:Al 10/31/2022 PER CODE(S):NEC 2020:690.56(C) ___ PAGE PV-5.0