Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD-23-003372
pubtiPtiP >jli cr)Z ONE & TWO FAMILY ONLY- BUILDING PERMIT Town of Yarmouth Building Department 1146 Route 28, South Yarmouth,MA 02664-4492 508-398-2231 ext. 1261 Fax 508-398-0836 -' : Massachusetts State Building Code,780 CIvR . -' "� ' i,. CEBVED Building Permit Application To Construct,Repair, Renovate Or Demolish 777 .--"' a One-or Two-Family Dwelling DEC 9 2022 This Section For Official Use Only Building Permit Number: P)Lb --Ai 0033 7j)ateApplied: BUILDING DEPARTMENT -: .-4..1. _ itilil"3/ in j 2 /fez Building Oial( Name) Si ature Date SECTI N 1: ITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 108 Blue Rock Rd 11 17 1.1 a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required I Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) , 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Zone: Outside Flood Zone? _ Public 0 Private 0 Check if yes❑ Municipal 0 On site disposal system 0 SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record:Alicia Rodriguez Yarmouth MA 02664 Name(Print) City,State,ZIP 108 Blue Rock Rd (774) 268-1236 alicia.capecod@gmail.com No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK'-(check all that apply) New Construction 0 I Existing Building 0 Owner-Occupied 0 1 Repairs(s) 0 1 Alteration(s) 0 1 Addition 0 Demolition 0 Accessory Bldg. 0 Number of Units i Other 0 Specify: I Brief Description of Proposed Work2: I Installation of an interconnected PV system including 14 panels at 5.46 Kw DC SECTION 4:ESTIMATED CONSTRUCTION COSTS 1 Item Estimated Costs: Official Use Only (Labor and Materials) I.Building $ 3194 1. Building Permit Fee:$ Indicate how fee is determined: ! 2.Electrical $7453 I 0 Standard City/Town Application Fee ❑Total Project Cost3(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees:$ Check No. Check Amount: Cash Amount: 6.Total Project Cost: $ 10647 0 Paid in Full 0 Outstanding Balance Due: • SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-040622 08/01/2023 Stephen Kelly License Number Expiration Date Name of CSL Holder 16 Parkway Rd. List CSL Type(see below) U No.and Street Type Description Stoneham MA, 02180 U Unrestricted(Buildings up to 35,000 cu.ft.) R Restricted l&&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 978 793-7881 eastmapermits@sunrun.com I insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) HIC 180120 10/13/2024 Sunrun Installation Services Inc./Stephen Kelly HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 21 Worlds Fair Dr. eastmapermits(cDsunrun.com No.and Street Email address Somerset, NJ, 08873 City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes No ❑ . SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Sunrun Installation Services Inc./Stephen Kelly to act on my behalf,in all matters relative to work authorized by this building permit application. See Attached Contract 12/07/2022 Print Owner's Name(Electronic Signature) Date • SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Stephen Kelly 12/07/2022 Print Owner's or Authorized Agent's ame( ctronic Signature) Date NOT+ : 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.aov/oca Information on the Construction Supervisor License can be found at www.mass.aov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" Commonwealth of Massachusetts 111 7lvlsion or ProressiOrtal Ltcensure Unrestricted-Buildings of any use group while chin Board of Butldrag Regulations amd Standards less than 35,000 cubic feet fff11 cubic meters)ei ent100er `�t-tP{lry,sor fie. • CS-040622 fires:08101'2023 STEPHEN A BELLY 16 PARKWAY-ROAD., '' STONEHAN gii 02 f 4 Failure to possess a current edition of the IAWOC—. Commissionera.rQt i( T jr„ State Building Code is cam Scenes, revocation Of this 8 . For I ntonrnalfon about this license Cap(617)7T7-3200 or visit wwmess.govidpi THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs and Business Regulation 1000 Washingtop:S)r4et-Suite 710 Bostorkittuttetts 02118 Home Improvement ebntractor Registration j - -i $ Supplement card ssastheion SUNRUN INSTALLATION SERVICES INC. ( 21 WORLDS FAIR DR - E anon tOr19RC24 SOMERSET,NJ 08873 �y 7M Nya L OW IWWes and RNun Cent THE COMMONWEALTH OF MASSACHUSETTS Mat of Cmaunsr Affskru&Bosnia.Reguluuon Ra strabon.aid br tndivutual um on1T b i o UM HOME WPROVEMEN/CONTRACTOR esplrenon 0410.R found Munn to: TYPE:Supplement Gard OR of Consumer Affairs and Summits Requlatlon aa1Wt 5 Exakelop 1000 WasNn91on Strout•Sults 110 100120 5.r 10/13/2024 Bouton.MA 02115 SUNRUN INSTALLATION sesuoos INC. STEPHEN KELLY 225 BUSH STREET ,,,r r .:�...•. SUITE 1400 — SAN FRANgBCO,CA 94104 Underv.=crstary valid without g0ature Stephen A Kelly 695 Myles Standish Blvd Taunton MA 02780 TEL:978-793-7881 Email: eastmapermits@sunrun.com i Tke Commonwealth of Massachusetts -„z Department of Industrial Accidents __� I Office of Investigations Lafayette City Center 2 Avenue de Lafayette, Boston,MA 02111-1750 ` www.mass.gov/dia Workers'Compensation Insu ranee Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name(Business/Organization/Individual): Sunrun Installation Services /Stephen Kelly Address:225 Bush St STE 1400 City/State/Zip: San Francisco CA 94104 Phone #: 978 793-7881 Are you an employer? Check the appropriate box: Type of project(required): 1.® I am a employer with 50 4. ❑ I am a general contractor and 1 employees(full and/or part-time).* have hired the sub-contractors 6. El New construction 2.0 I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have 8. ❑ Demolition workingfor me in anycapacity. employees and have workers' 9. ❑ Building addition [No workers' comp. insurance comp. insurance.* required.] 5. 0 We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] ` c. 152,§1(4),and we have no employees. [No workers' 13.1Z Other Roof Mounted Solar comp. insurance required.] _ *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I mn an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: American Zurich Insurance Company Policy#or Self-ins. Lic. #:WC614287601 Expiration Date: 10/01/2023 Job Site Address: 108 Blue Rock Rd City/State/Zip: Yarmouth MA 02664 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of i Investigations of the DIA for insurance coverage verification. 1 do hereby certify under the pains and penalties of perjuty that the information provided above is true and correct. Signature: rs23, Date: 12/07/2022 Phone#: 978-793-7881 i Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(check one): 10Board of Health 2121 Building Department 30City/Town Clerk 4.0 Electrical Inspector 59Plumbing Inspector 6.❑Other Contact Person: Phone#: ,�--...4 SUNRINC-02 LWANG2 Ac L R0 CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDDIYYYY) `....----- 8/31/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER License#0C36861 CONTACT Walter Tanner NAME: Alliant Insurance Services,Inc. PHONE FAX 560 Mission St 6th Fl (A/C,No,Ext): (A/C,No): San Francisco,CA 94105 E-MAIL ADDRESS:Walter.Tanner@alliant.com INSURER(S)AFFORDING COVERAGE NAIC• INSURER A:Evanston Insurance Company L35378 INSURED INSURER B:James River Insurance Company _ 12203 Sunrun Installation Services,Inc INSURER c:American Zurich Insurance Company 40142 775 Fiero Lane,Suite 200 Ph#805-540-7643 INSURER D: San Luis Obispo,CA 93401 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN. THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL'SUER POLICY NUMBER POLICY EFF ' POLICY EXP T LIMITS LTRINSD WVD (MMIDDIYYYY) IMMIDD/YYYY] A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE I$ 2'000'000 CLAIMS-MADE X OCCUR MKLV5ENV103749 10/1/2022 10/1/2023 DAMAGE TO EaEocccurence) $ 1,000,000 MED EXP(Any one person) I$ 5,000 PERSONAL&ADV INJURY {$ 2'000'000 _GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE 1$ 2'000'000 X POLICY X JECT LOC PRODUCTS-COMP/OP AGG $ 2,000,000 X_ ,,OTHER:Retention:$100,000 Per Project Agg $ 5,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT (Ea accident) I$ ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY 'AUTOS ED BODILY INJURY(Per accident) $ _._.AUTOS ONLY AUUTOS ONLY (Uer de�4AMAGE $ $ B UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 4,000,000 X EXCESS LIAB CLAIMS-MADE 001072261 10/1/2021 10/1/2022 AGGREGATE $ 4,000,000 I DED RETENTION$ 3 C I WORKERS COMPENSATION 1 PER 'AND EMPLOYERS'LIABILITY x STATUTE ERH Y/N WC614287601 10/1/2022 10/1/2023 1,000,000 ANY PROPRIETOR/PARTNER/EXECUTIVE N NIA I E.L.EACH ACCIDENT $ F gills VIg EXCLUDED? andatory m N ) E.L.DISEASE-EA EMPLOYE $ 1,000,000 If yes.describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT�$ 1 I I DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) Workers'Compensation Policy WC614287601 Deductible:$1,000,000. Re:Permitting within jurisdiction. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of Yarmouth THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN of Yam ACCORDANCE WITH THE POLICY PROVISIONS. 1146 28 South Yarmouth,MA 02664-4492 AUTHORIZED REPRESENTATIVE ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD . . . : . , Sunrun BrightSave TM Agreement Alicia Rodriguez 108 Blue Rock Rd, Yarmouth, MA, 02664 Take Control of Your Electric Bill $0 25 Years $ 107 $0 .280 Deposit due Agreement Term Length Monthly Bill for Year Year 1 Cost per kWh Today (3.5% annual increase One (plus taxes, if applicable; (excluding upfront in monthly bill) includes $7.50 discount for payment, if any) Auto-Pay enrollment) WE'VE GOT YOU COVERED WITH OUR WORRY-FREE SERVICE .vol," :-2? (7) Al We provide hassle-free We monitor the system We warrant. insure. Selling your home? design, permitting, and to ensure it runs maintain and repair We guarantee the buyer installation. properly. the system. We will qualify to assume also provide a 10- your agreement. year roof warranty. A SOLAR SYSTEM DESIGN FOR YOUR HOME You get a 6.21 kW DC Solar System With 17 Solar Panels and 1 Inverter(s) Which will produce an est. 4,592 kWh in its first year And offset approx.65% of your current, estimated electricity usage YOUR SALES REPRESENTAT Aarron Wag: aarron.wagstaff sunrun.. (8 1) 971-5 By signing below, you acknowledge that you have reviewed and received a complete copy of the Agreement without any blanks. Such Agreement shall be the complete understanding between the Parties. SUNRUN r T11pN SERVICES INC. Signatur ` „?..... 8A730000679142D... Print Name: Mark vi 11 anueva Date: 10/212022 Title: Praj_ecr operations Federal Employer Identification Number: 26-2841711 IF YOU CHOOSE TO PAY BY CHECK, MAKE CHECKS OUT TO SUNRUN INC. NEVER MAKE A CHECK OUT TO A SALES REPRESENTATIVE. OUR SALES REPRESENTATIVES ARE NOT AUTHORIZED TO RECEIVE CHECKS IN THEIR OWN NAMES. YOU MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF THE TENTH EFFECTIVE DATE. PLEASE REVIEW THE ATTACHED NOTICES OF CANCELLATION FOR AN EXPLANATION OF THIS RIGHT. Customer ePrirearepAtecount Holder Secondary Account Holder (Optional) 0.Qi ciu, ks,dn i o ua `-68stpitallot Alicia Rodriguez Signature 10/21/2022 Date Print Name Email Address*: al i ci a.capecod@gmai 1 .com Mailing Address: 108 Blue Rock Rd Yarmouth, MA 02664 Phone: (774) 268-1236 Email addresses will be used by Sunrun for official correspondence. such as sending monthly bills or other invoices. Sales Consultant By signing be/ow/acknowledge that/am Sunrun accredited, that/presented this agreement according to ELcsi w Code of Conduct, and that/obtained the homeowner's signature on this agreement. AAArk, lklurk-ai tiVigttYg Aarron wagstaff Print Name 7372667023 Sunrun ID number Sunrun Installation Services Inc. 1225 Bush Street. Suite 1400. San Francisco. CA 94104 1888.GO.SOLAR I HIC §TOWN OF YARMOUTH 1146 Route 28, South Yarmouth, MA 02664 508-398-2231 ext. 1261 Fax 508-398-0836 Office of the Building Commissioner BUILDING DEPARTMENT DEMOLITION DEBRIS DISPOSAL AFFIDAVIT Pursuant to M.G.L. Ch. 40, §54 and 780 CMR- Section 105.3.1. #4. I hereby certify that the debris resulting from the proposed work/demolition to be conducted at 108 Blue Rock Rd Work Address Is to be disposed of oat the following location: 695 Myles Standish Blvd. Taunton, MA 02780 Said disposal site shall be a licensed solid waste facility as defined by M.G.L. Ch. 111, §150A. a 12/07/2022 Signatur of Applicatio Date Permit No. SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE N DESCRIPTION MI •SYSTEM SIZE:5460W DC,3800W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), SERVICE ENTRANCE •MODULES:(14)TRINA SOLAR:TSM-390DE09C.07 MUNICIPAL CODE,AND ALL MANUFACTURERS LISTINGS AND INSTALLATION PV-1.0 COVER SHEET MA •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. PV-2.0 SITE PLAN SE3800H-USMN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. MP MAIN PANEL •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, PV-3.0 LAYOUT SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV-4.0 ELECTRICAL SP SUB-PANEL •NEW 100AMP MAIN BREAKER KIT TO BE INSTALLED. •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 0 SUNRUN METER •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM DEDICATED PV METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES.ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ACAC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. [DC DC DISCONNECT(S) •13.35 AMPS MODULE SHORT CIRCUIT CURRENT. CB IQ COMBINER BOX •20.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(8)]. •PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(B)(2). ABBREVIATIONS I——I INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE A AMPERE L_I SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ALTERNATING CURRENT S u n r u n AFC ARC FAULT CIRCUIT INTERLIPTER _ _ CHIMNEY KIM ALMUTH COMP COMPOSITION OC DIRECT CURRENT ATTIC VENT VICINITY MAP a180120 EXISTING ExISTG FLUSH ATTIC VENT PVC PIPE VENT 0 s TARDOM KW.TAUNIO..Mk MOM, ESS ENERGY STORAGE SYSTEM 0 EDT EXTERIOR S METAL PIPE VENT Cr eans CUSTOMER RESIDENCE: INT INTERIOR ® T-VENT ? MS MAIN SERVICE PANEL `(6rev;Ste 108 BLUE ROCK RD, RI/ NEW SATELLITE DISH (1.!`!.) YARMOUTH,MA,02664 NCR NOT TO SCALE Denn.s TEL TEL.(774)288-1238 CC ON CENTER EZ FIRE SETBACKS APN,YARM-000111-000017 EEI e PREFAB PRE-FABRICATED Barnstac.e , _,., ;.IR;T . PROJECT NUMBER: :J PSE POUNDS PER SQUARE FOOT ,: HARDSCAPE f»Y ' 1,n atnaTI.. 223R-108RODR PV PHOTOVOLTAIC ha NtCn DESIGNER (415)580-6920 ex3 RSO RAPIDSHUTDONM DEVICE —PL— PROPERTY LINE COSOLAR MODULES O SUMAIR KHAN TL TRANSFORMERLESS SCALE NTS TYP TYPICAL — SHEET ✓ VOLTS REV NAME DATE _ _ COMMENTS COVER SHEET W WATTS 1111111111.11 REV Al 12/3/2022 LAN LANDSCAPE SNR MOUNT - PAGE PV-1.0 POR PORTRAIT SNR MOUNT&SKIRT Tsmpete mnAP_4086 SITE PLAN-SCALE=3/3r=1'-0" SITE PLAN DETAIL-SCALE=1/128"=1'-0" 45 (E)RESIDENCE (E)RESIDENCE ------- - • L............._._...------- -� BLUE ROCK RDC... PI- (N)ARRAY AR-01 sunrun #180120 OM MYLES 31.10.YVO.TAIMON.W.elI<)STi WOW 0 fEAO AMP CUSTOMER RESIDENCE: ALICIA RODRIGUEZ SE 108 BLUE ROCK RD, YARMOUTH,MA,02864 INV PM AC TEL.(774)288-1236 ARRAY TRUE MAG PV AREA qpN:YARM-00011 1-00 0017 PITCH AZIM AZIM (SOFT) PROJECT NUMBER: AR-01 21° 91° 105° 289.7 223R-108RODR DESIGNER: (415)580-6920 ez3 SUMAIR KHAN SHEET SITE PLAN REV:Al 12/3/2022 PAGE PV-2.O Tempre."rsm_4.n es ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height TypeMax OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF g Detail OC Spacing Overhang OC Spacing OverhangConfigurationn Span Spacing SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-El COMP SHINGLE-RLU 2-Story 2X8 RAFTERS 12'-6" 16" COMP,SEE DETAIL SNR-OC-00436 NA NA STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREW 01-AR-01-SCALE:114"=1'-0" 5/16".2.5"MIN.EMBEDMENT AZIM:91' PITCH:21° .1 I 1 t_ • - ❑ ❑ -- ❑ o ❑---3 - r ❑ 10'-11" O 5'-4"TYP El—Ei 0 ❑ --E1--8 63 0 0 0 _ 00 0 0 C) 1'-0" sunrun ____ #160120 ANDISH WM.TAUNTON.M.o2,.11.M, WOK. FAX CUSTOMER RESIDENCE: ALICIA RODRIGUEZ 108 BLUE ROCK RD, STRUCT, YARMOUTH,MA,02664 OHL IN�. INSTALLERS SHALL NOTIFY ENGINEER OF ANY �y� � POTENTIAL STRUCTURAL ISSUES OBSERVED TEL(774)268-1236 �� v1NCENT y6x, PRIOR TO PROCEEDING W/INSTALLATION. APN:YARM-000111-000017 MWUMVANEZA N PROJECT NUMBER. CIVIL •IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" 223R-106RODR EO yQ Signed 12/06/2022 BOUNDARY REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS),THEN (415)560-6920 cr3 ON�LEH���`• ATTACHMENTS NEED TO BE ADDED AND DESIGNER: OVERHANG REDUCED WITHIN THE 12" SUMAIR KHAN BOUNDARY REGION ONLY AS FOLLOWS: SHEET **ALLOWABLE ATTACHMENT SPACING LAYOUT INDICATED ON PLANS TO BE REDUCED BY 50%. "ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE REV:Al 12/3/2022 SEE SITE PLAN FOR NORTH ARROW. ATTACHMENT SPACING INDICATED ON PLANS. PAGE PV-3.0 ranpre.enon_d 0 86 120/240 VAC SINGLE PHASE SERVICE METER U. O EVERSOURCE 2376119 UTILITY GRID (I EXISTING 100A MAIN BREAKER DISCONNECT WITH 100A MAIN 1 ENCLOSURE LOAD SIDE TAP (N) ABLE (` NEW 100A BLADE TYPE BLADE TYPE (N)MA SMART SOLAREDGE TECHNOLOGIES: MAIN FUSED AC UTILITY BREAKER DISCONNECT REVENUE SE3800H-USMN 3800 WATT INVERTER JUNCTION BOX PV MODULES �� EXISTING A METER 3 n OR EQUIVALENT n / TRINA MODULES TSM-3900E09C.07 < 125A MAIN �y_ .�-„�, O ✓. _ ,_,i; ldyJ ___._ `Z t•// OPTIMIZERS WIRED IN: PANEL FACILITY (1)SERIES OF(74)OPTIMIZERS LOADS 20A FUSES I 1 I 1 SQUARE O 240V METER SOCKET LOAD RATED DC DISCONNECT L D221NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R,30A UTILITY SIDE OF CIRCUIT COMPLIANT S440 • 120240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND - 1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER s u n r u n 2 3)4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/T1-11AIN-2 3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 I #180120 006 MYLES 91 09M KW.3NI01Tgi.MA 1021667331 MI 0 CUSTOMER RESIDENCE: ALICIA RODRIGUEZ 108 BLUE ROCK RD, YARMOUTH,MA,02664 MODULE CHARACTERISTICS g440 OPTIMIZER CHARACTERISTICS: TEL.(774)268-1236 TRINA SOLAR:TSM-390DE09C.07: 390 W MIN INPUT VOLTAGE: 8 VDC APN:YARM-000111-000017 OPEN CIRCUIT VOLTAGE: 40.8 V MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: MAX POWER VOLTAGE: 33.8 V MAX INPUT ISC: 14.5 ADC 223R-108RODR SHORT CIRCUIT CURRENT: 13.35 A MAX OUTPUT CURRENT. 15 ADC DESIGNER: (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 SUMAIR KHAN SYSTEM SIZE 5460 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE 14 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:Al 12/3/2022 SYSTEM OPERATING CURRENT. 14.37 A SYSTEM SHORT CIRCUIT CURRENT: 15 A PAGE PV-4.0 688618,86888,10.86 • "iiitA\ INVERTER 1 \AfA ..' •NOTES IGNS L SHALL •rM •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ. --_- -- •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE MAXIMUM SYSTEM VOLTAGE, 480 VDC WORDS,ON LINE AND LOAD COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN •LABELS SHALL H LLPERMANENTLYB AFFIXED TO THE EQUIPMENT OR WIRING LABEL LOCATION METHOD AND SHALL NOT BE HAND WRITTEN THE OPEN POSITION INVERTER(S),DC DISCONNECT(S) •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S).NEC 2020.690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z5354-2011,PRODUCT SAFETY INVERTER(S).AC/DC DISCONNECT(S). SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S).NEC 2020 690.13(B) WARNING: PHOTOVOLTAIC / WAR POWER SOURCE k. LABEL LOCATION DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS. ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS -- AND PV SOLAR ELECTRIC PER CODES)NEC 2020:690.31(D)(2),IFC 2012 SYSTEM 605.11.10 A U T I N L i ■ LABEL LOCATION: UTILITY SERVICE METER AND MAIN ■ SERVICE PANEL. PER CODE(S):NEC 2020:705.12(C) MULTIPLE SOURCES OF POWER !WARNING RAPID SHU T JOWN SWITCH POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION. I�i/ i INSTALLED WITHIN 3'OF RAPID SHUT DOWN LABEL LOCATION SWITCH PER C1.NEC 2020 690 56(C1(2)IFC s u n r u n IFC 20 ADJACENT TO PV BREAKER AND ESS 2012:805.11.1,IFC 2018-.1204.5.3 OCPD(IF APPLICABLE). PER CODE(S).NEC 2020 4' , 705 12(8)(3X2) � / SOLAR PV SYSTEM EQUIPPED SOLAR PANELS alaolzo PHOTOVOLTAIC SYSTEM WITH RAPID SHUTDOWN ON ROOF ss='�1BL"nT"' a"w^2'1""'1 COMBINER PANEL i `•10 DO NOT ADD LOADS Nil I CUSTOMER RESIDENCE: LABEL . ALICIA RODRIGUEZ LOCATION PHOTOVOLTAIC AC COMBINER(IF ¶INVERTER(EXT) 108 BLUE ROCK RD, YARMOUTH,MA,02664 PPRUCABLS).PER CODE(S):NEC 2020:705.12(D)(2X3)(U TURN RAPID SHUTDOWN —PV PRODUCTION METER SWITCH TO THE"OFF" —AC DISCONNECT TEL.(774)268-1236 _ POSITION TO SHUT DOWN APN,YARM-000111-000017 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE —SERVICE ENTRANCE PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT 16.00 AMPS SHOCK HAZARD IN THE ARRAY. MI -MAIN PANEL(INT) 22 R-108RODR NOMINAL OPERATING AC VOLTAGE 240 VAC DESIGNER: (415)580-6920 ex3 LABEL LOCATION. 108 BLUE ROCK RD, YARMOUTH, MA, 02664 SUMAIR KHAN AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. �� SHEET PER CODE(S)NEC 2020,690.54 LABEL LOCATION. PER CODE(S):NEC 2020:705.10,710.10 SIG NAGS ON OR NO MORE THAT/M(3 FT)FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV Al 12/3/2022 PER CODE(S).NEC 2020,690,56(C) PAGE PV-5.0 remdere_ i 0 36 EV projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.com 12/6/2022 RE:Structural Certification for Installation of Residential Solar ALICIA RODRIGUEZ:108 BLUE ROCK RD,YARMOUTH, MA,02664 Attn:To Whom It May Concern This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report,the roof is made of Composite shingle roofing over roof plywood supported by 2X8 Rafters at 16 inches.The slope of the roof was approximated to be 21 degrees. After review of the field observation data and based on our structural capacity calculation, the existing roof framing has been determined to be adequate to support the imposed loads without structural upgrades. Contractor shall verify that existing framing is consistent with the described above before install.Should they find any discrepancies,a written approval from SEOR is mandatory before proceeding with install. Capacity calculations were done in accordance with applicable building codes. Design Criteria Code 2015 IRC(ASCE 7-10)-CMR 780 9th Ed Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 140 mph PV Dead Load DPV 3 psf Exposure C Roof Live Load Lr 20 psf Ground Snow S 30 psf If you have any questions on the above, please do not hesitate to call. STRUCT ONL �tHOF,N4S Sincerely, ��E9 syc o ti 44' VINCENT -P Vincent Mwumvaneza, P.E. o MWUMVANEZA EV Engineering, LLC Ni.CIVIL 2 proiects@evengineersnet.com rolects@evengneersnet.com ��i EQ�p • http://www.evengineersnet.com '.� Signed 12/6/2022 1/1 =Nif EV projects@evengineersnet.com 276-220-0064 lima ENGINEERS http://www.evengineersnet.com Structural Letter for PV Installation 12/6/2022 Job Address: 108 BLUE ROCK RD YARMOUTH, MA,02664 Job Name: ALICIA RODRIGUEZ Job Number: 120622AR Scope of Work This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing.All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Table of Content Sheet 1 Cover 2 Attachment checks 3 Snow and Roof Framing Check 4 Seismic Check and Scope of work Engineering Calculations Summary Code 2015 IRC(ASCE 7-101-CMR 780 9th Ed Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 30 psf Wind Load (component and Cladding) V .. ,e-..._.A. mph Exposure C References NDS for Wood Construction STRUCT ONL ��SF1"nulssq 4� Cy Sincerely, � VINCENT �t, o MWUMVANEZA CIVIL . 2 Vincent Mwumvaneza, P.E. i EV Engineering, LLC % "�%: tit �`�:� NGa Signed 12/6/2022 proiects(a�evengineersnet.com oNA�E http://www.evengineersnet.com 1/1 • • = EV projects@evengineersnet.com 276-220-0064 MIN ENGINEERS http://www.evengineersnet.com Wind Load Cont. Risk Category= II ASCE 7-10 Table 1.5-1 Wind Speed(3s gust),V= mph ASCE 7-10 Figure 26.5-1A Roughness= C ASCE 7-10 Sec 26.7.2 Exposure= C ASCE 7-10 Sec 26.7.3 Topographic Factor, Kn= 1.00 ASCE 7-10 Sec 26.8.2 Pitch= .', j:Degrees Adjustment Factor,X= 1.35 ASCE 7-10 Figure 30.5-1 a= 3.00 ft ASCE 7-10 Figure 30.5-1 Where a:10%of least horizontal dimension or 0.4h,whichever is smaller,but not less than 4%of least horizontal dimension or 3ft(0.9m) Uplift(0.6W). Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= -29.3 -41.3 -65.1 Figure 30.5-1 Pnet=0.6 x A x KZT x Pnet30)= 23.75 33.46 52.75 Equation 30.5-1 Down pressure(0.6W1 Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= 15.7 15.7 15.7 Figure 30.5-1 Pnet=0.6 x it x KZT x Pnet30)= 12.73 12.73 12.73 Equation 30.5-1 Rafter Attachments:0.6D+0.6W(CD=1.6) Connection Check Attachement max.spacing ;' , ;`53'ft 205 Ibs/in Lag Screw Penetration 2.5 in Allowable Capacity= 512.5 0.6D+0.6W Dpv+0.6W Zone Trib Width Area(ft) Uplift(Ibs) Down(Ibs) 1 5.3 11.4 250.1 179.2 2 5.3 11.4 360.7 179.2 3 3 6.5 328.6 101.4 Max= 360.7 < 512.5 CONNECTION IS OK 1. Pv seismic dead weight is negligible to result in significant seismic uplift,therefore the wind uplift governs 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. 1/1 =y EV projects@evengineersnet.com 276-220-0064 wow ENGINEERS http://www.evengineersnet.com Vertical Load Resisting System Design Roof Framing Ell Pg= 30 psf ASCE 7-10,Section 7.2 pf= 21 psf Ce= 0.9 ASCE 7-10,Table 7-2 pfmin.= 25.0 psf Ct= 1.1 ASCE 7-10,Table 7-3 ps= 25 psf 27.2 plf Is= 1.0 ASCE 7-10,Table 1.5-1 CS 0.817 Max Length,L= 12.50 ft Tributary Width,WT= 16 in Dr= 10 psf 13.33 plf PvDL= 3 psf 4 plf Load Case: DL+0.6W Pnet+PP4cos(6)+Po1= 34.3 plf Max Moment, Mu= 519 lb-ft Conservatively Pv max Shear 179.2 lbs Max Shear,Vu=wL/2+Pv Point Load = 288 lbs Load Case: DL+0.75(0.6W+S)) 0.75(Pnet+Ps)+ PPVcos(6)+PDL= 50 plf Mdowf 760 lb-ft Mallowable=Sx x Fb'(wind)= 2116 lb-ft > 760 lb-ft OK Load Case: DL+S Ps+PPvcos(6)+PDL= 44 plf Mdown= 670 lb-ft Mallowable=Sx x Fb' (wind)= 1521 lb-ft > 670 lb-ft OK Max Shear,V„=wL/2+Pv Point Load= 314 lbs Member Capacity SPF Wit2 2X8 Design Value Ci CF C; Cr Adjusted Value • Fb= 875 psi 1.0 1.2 1.0 1.15 1208 psi F, = 135 psi N/A N/A 1.0 N/A 135 psi E= 1400000 psi N/A N/A 1.0 N/A 1400000 psi Depth,d= 7.25 in Width,b= 1.5 in Cross-Sectonal Area,A= 10.875 in2 Moment of Inertia,I„= 47.6348 in4 Section Modulus,Sxx= 13.1406 in3 Allowable Moment,Map=Fb'Sx5= 1322.3 lb-ft DCR=M /Mtp ali= 0.42 < 1 Allowable Shear,Va„= 2/3Fv'A= 978.8 lb DCR=V /Va„= 0.16 < 1 Aida' 1/1 � ' s = E♦/ projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.com Siesmic Loads Check Roof Dead Load 10 psf %or Roof with Pv 14% Dpv and Racking 3 psf Averarage Total Dead Load 10.4 psf Increase in Dead Load 1.7% OK The increase in seismic Dead weight as a result of the solar system is less than 10%of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on information in pictures and a drawing set titled PV plans -ALICIA RODRIGUEZ.The analysis was according to applicable building codes, professional engineering and design experience,opinions and judgments.The calculations produced for this structure's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. 1/1