HomeMy WebLinkAboutEngineer PlanLOCATION MAP
rTe�
OAY
.t °o
V
ASSESSORS MAP: Z�
REI=ERENCE: 9 (-U� o5o��'
mm 1*4 * 1 it, rg A4
^..
2 3clo
- - U nOF 7
PINE CONE DRI E _..
ILE
100.00,
W`
.-Ao
-;PC
TEST HOLE LOGS
SOIL EVALUATOR: ' �1;vv, AA�4, Ct6
1A/ITNFCC• • �'�i/ t1 ' T
0jr -
DATE:
PERCOLATION RATE: -�-- 2 l 14, 1
A -
T.H.#1 ELEV. _...-10D..._ T.H.#2 ELEV.
1)
The instaliqtIon shalt comply with the State Environmental Code Title V and Town of
Board of Health Regulations.
2)
The septic system as proposed on this plan shall not be installed until a licensed town
MAR 2 4 2023
installer receives approval and an installation permit from the applicable town.
HEALTH DEPT 3)
Prior to installation, the installer shall verify the location of utilities, sewer inverts,
sewer lines and existing septic components prior to installation.
4)
All gravity sewer piping is to be 4 inch schedule 40 PVC at 1/8" per foot. The first 2
feet out of the distribution box shall be level. All piping connections to be glued.
S)
This septic design plan Is not to be utilized for property line determination or for any
other purpose other than the proposed septic system installation.
6)
All Title V components are to meet Title V specifications.
7)
Parking shall be prohibited over Title V components unless components are H2O
loaded.
8)
The existing leaching or cesspools shall be pumped and filied with material per Title V
abandonment procedures. Leaching and cesspool(s) and contaminated soils within
the proposed SAS shall be removed and replaced with clean sand per Title V
specifications.
9)
Septic components are to be 10' from a water service line. Sewer lines crossing a
water line shall be sleeved with an appropriately sized schedule 40 PVC with ends
grouted. The water service line or the septic line can be sleeved with the sleeve being
a distance of 10' on both sides of crossing the line.
10) If a garbage grinder exists in the structure, it is to be removed if the septic system is
not designed to accommodate a garbage grinder.
11) the installer is responsible for care of excavation around all utilities on the property
and protecting the structural integrity of all structures during the installation process
SEPTIC SYSTEM DESIGN CALCULATIONS
of .the septic system.
FLOW ESTIMATE: 12) This plan only represents that a septic system can be installed on the property
15 BEDROOMS AT (# Q GAL/DAY/BDRM = 155C) GAL/DAY meeting Title V requirements.
13) The property owner shall review design criteria to approve the total number of
SEPTIC TANK: j bedrooms and design flow. Installation of the septic system as proposed and receipt
5570 GAL/DAY/BDRM X 2 DAYS = i y 00 GALLONS of payment for the design shall be deemed approval of the design criteria by the
property owner or agent of.
USE _ GALLON SEPTIC TANK (Ey',J 14) The validity of this plan shall expire with the expiration of the town installation permit
(GARBAGE GRINDER IS PROHIBITED) issued for this plan or the validity of this plan shall expire on the expiration of the
SOIL ABSORPTION SYSTEM: Certificate of Compliance !Wed for the installation of the proposed system on this
U�6 N 2 H -
SIDEWALL AREA: Z )(- L.]
BOTTOM AREA:
SEPTIC SYSTEM SECTION
BENCHMARK
TOP OF FOUNDATION
ELEV. 311'•
(DATUM ASSUMED)
Y
OF M,jSS�
STEVEN W. N
o RUMBA
No. 35791 0
3 L 3 -- 2..3
A
GALLONS
SEPTIC TANK
�
Yarmouth Finalth Department
APPR VED
ame Date
WATER TEST FOR LEVELNESS