HomeMy WebLinkAboutUntitled INSURANCE COVERAGE:
I have a current liability insura e policy or its equivalent which meets the requirements of
M.G.L. Ch. 112 Yes ✓No
If you have checked Yes, indicate the type of coverage by checking the appropriate box below:
A liability insurance policy ✓Other type of indemnity Bond
OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by
Chapter 112 of the Massachusetts General Laws, and that my signature on this permit application waives this
requirement.
Check One Only
Owner Agent
Signature of Owner or Owner's Agent
By checking here ,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true
and accurate to the best of my knowledge and that all sheet metal work and installation performed under the permit issued for this application
will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws.
Inspections shall be called for prior to insulation installation.
Duct inspection required prior to insulation installation: Yes No
Date: Comments:
Date: Comments:
Type f license:
V...4e
By: Master
Title: Master-Restricted Sig to of Licensee '1`
City/Town: Journeyperson
Permit#: Journeyperson-Restricted License Number: 9/6
Fee: $ � Check at www.mass.gov/dpl
Inspector Signature of Permit T
of Permit Approval
AGHUSETTS"' °RCEED E
• ``• :NOT FOR FEDERAL IDMIMBE .
tia 0911312020 S 191 951901
CtAS' "' I28I2o25 0812811954 =
D s EST NONE
?GREGORY J
ry73LAFRANCEAVE
HYANNIS,MA 02601.2432 ,
EYE6 BLu • 08128154
sex M
•
i NOT 5�10"
• DD 0911412t 2O Rev 0212712016 •
•
DO
pROF ;r "MONW ALTH O
VI S ION OF S '`�lUENSIE RE,EIO LICSU BiOMBSSNAL pF
SHEET MB1'AL YvuR�"RS;
ISSUES T..HE FOLLO
�� WING LICENSE
A51 ER-
UNRESTRICTED
GR EGORY J HOUDE
73LAF
•
�NCEAIIE � ,.
HYANNIS 14{A O26n1-2432
a„ W
LICENSE NUMBER ° 202 11275$
EXNIRA7IUN DATE
SERIAL NUMBER
•
•
•
•
•
•
FW Webb Company Houde HVAC
108 Breeds Hill Rd -Hyannis, Ma 02601 Based on provided plans
508 775 3890 -
Sales Consultant:
`� Job#: 33 Cranberry Lane
Date: 08/23/2022
System I (Average Load Procedure)
Design Conditions
Location: Barnstable, Massachusetts Elevation: 30 ft Daily Range: Medium
Input Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 42° N Design Grains: 28
Summer: 88 70 Heated Area 1361 Sq.Ft.
Winter: 12 74 Cooled Area 1361 Sq.Ft.
Heat/Loss Summary (July Heat Load Calculations)
Gross Sensible Latent
Area Loss Gain Gain
Walls 1524 5401 1768 0
Windows 164.175 3357 3998 0
Doors 20.01 484 242 0
Ceilings 675 1223 531 0
Skylights 0 0 0 0
Floors 1386 1216 405 0
.� Room Internal Loads 0 8935 2373
Blower Load 1707 0 nw�.
Hot Water Piping Load 0 0 0 , ,
nnNRY
Winter Humidification Load 1795 0 0
Infiltration 4194 506 486
Approved ACCA
Ventilation 1705 495 476 MJ8 Calculations
Duct Loss/Gain EHLF=0 ESGF=0 1016 524 333
AED Excursion n/a 0 n/a
Subtotal 20391 19111 3668
Total Heating 20391 Btuh
Total Cooling 22779 Btuh 41 Linear ft. of Hydronic Baseboard
1.74 Nominal Tons of Sensible Cooling 1.9 Nominal Tons of Total Cookrg,
AHRI �,/
Friedrich Reference System High Heat Low Heat
Model Number Indoor Type Capacity EER SEER 47 °F HSPF 17°F
204101247 Non-ducted Indoor Units 32000 12.50 21.00 36000 11.00 23200
FPHMR36A3A 203996910 Ducted Indoor Urits 32000 12.00 19.50 36000 10.80 22600
203999080 Mixed Ducted and Non-ducted 32000 12.25 20.25 36000 10.90 22600
Indoor Units
:L
Adtek AccuLoad Report Version 17.4.0 Page 1
L
L/
FW Webb Company Houde HVAC
108 Breeds Hill Rd -Hyannis, Ma 02601
508 775 3890 -
Sales Consultant:
Job#: 33 Cranberry Lane
Date: 08/23/2022
System I Load Chart
Heat Loss Percentages Walls
5% Windows&Skylights
8%
26% M Doors
Ceilings
21% Floors
Misc System Loss
II Infiltration
16% III Ventilation
9%
6% 6%2% Duct Loss
Heat Gain Percentages Walls
5% 4% 8% Windows&Skylights
5% Doors
19%
Ceilings
Floors
"�•. 1% Internal Gains
3%
2% U Infiltration
111 Ventilation
54%
Duct Loss
Adtek AccuLoad Report Version 17.4.0 Page 2
•.J
\../
\..1
FW Webb Company Houde HVAC
108 Breeds Hill Rd -Hyannis, Ma 02601
508 775 3890 -
Sales Consultant:
Job#: 33 Cranberry Lane
Date: 08/23/2022
Zone 1 1st Floor New Addition (Peak Load Procedure)
Design Conditions
Location: Barnstable, Massachusetts Elevation: 30 ft Daily Range: Medium
Input Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 42° N Design Grains: 28
Summer: 88 70 Heated Area 686 Sq.Ft.
Winter: 12 74 Cooled Area 686 Sq.Ft.
Heat/Loss Summary (July Heat Load Calculations)
Gross Sensible Latent
Area Loss Gain Gain
Walls 768 2429 796 0
Windows 145.485 2975 5188 0
Doors 20.01 484 242 0
Ceilings 0 0 0 0
Skylights 0 0 0 0
Floors 711 1216 405 0
--. Room Internal Loads 0 7254 1973
Blower Load 1318 Rmtt
Hot Water Piping Load 0 0 „
Winter Humidification Load 0 0
Infiltration 2114 255 245
Approved ACCA
Ventilation 990 383 367 MJ8 Calculations
Duct Loss/Gain 590 404 257
AED Excursion n/a n/a n/a
Subtotal 11840 16245 2843
Total Heating 11840 Btuh
Total Cooling 19088 Btuh 24 Linear ft. of Hydronic Baseboard
1.48 Nominal Tons of Sensible Cooling 1.59 Nominal Tons of Total Cooling
*Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA.All computed calculations are
estimates based on building use,weather data, and inputted values such as R-Values, window types, duct loss, etc.
Equipment selection should meet both the latent and sensible gain as well as building heat loss.
Adtek AccuLoad Report Version 17.4.0 Page 3
FW Webb Company Houde HVAC
108 Breeds Hill Rd -Hyannis, Ma 02601
508 775 3890 -
Sales Consultant:
Job#: 33 Cranberry Lane
Date: 08/23/2022
Zone 2 2nd Floor Loft (Peak Load Procedure)
Design Conditions
Location: Barnstable, Massachusetts Elevation: 30 ft Daily Range: Medium
Input Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 42° N Design Grains: 28
Summer: 88 70 Heated Area 675 Sq.Ft.
Winter: 12 74 Cooled Area 675 Sq.Ft.
Heat/Loss Summary (July Heat Load Calculations)
Gross Sensible Latent
Area Loss Gain Gain
Walls 756 2972 972 0
Windows 18.69 382 448 0
Doors 0 0 0 0
Ceilings 675 1223 531 0
Skylights 0 0 0 0
Floors 675 0 0 0
Room Internal Loads 0 1681 400
Blower Load 389 Iluzl,M
Hot Water Piping Load 0 0
"N ;
Winter Humidification Load 0 0
Infiltration 2080 251 241
Approved ACCA
Ventilation 715 113 108 MJ8 Calculations
Duct Loss/Gain 426 119 76
AED Excursion n/a n/a n/a
Subtotal 8551 4504 825
Total Heating 8551 Btuh
Total Cooling 5329 Btuh 18 Linear ft. of Hydronic Baseboard
0.41 Nominal Tons of Sensible Cooling 0.44 Nominal Tons of Total Cooling
*Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA.All computed calculations are
estimates based on building use, weather data, and inputted values such as R-Values, window types, duct loss, etc.
Equipment selection should meet both the latent and sensible gain as well as building heat loss.
Adtek AccuLoad Report Version 17.4.0 Page 4
v II
v
FW Webb Company Houde HVAC
108 Breeds Hill Rd -Hyannis, Ma 02601
508 775 3890 -
Sales Consultant:
`-- Job#: 33 Cranberry Lane
Date: 08/23/2022
Kitchen (Peak Load Procedure)
Design Conditions
Location: Barnstable, Massachusetts Elevation: 30 ft Daily Range: Medium
Input Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 42° N Design Grains: 28
Summer: 88 70 Heated Area 286 Sq.Ft.
Winter: 12 74 Cooled Area 286 Sq.Ft.
Heat/Loss Summary (July Heat Load Calculations)
Gross Sensible Latent
Area Loss Gain Gain
Walls 296 1000 327 0
Windows 28.035 573 1310 0
Doors 20.01 484 242 0
Ceilings 0 0 0 0
Skylights 0 0 0 0
Floors 286 489 163 0
Room Internal Loads 0 2920 1173
Blower Load 380 499 0
Hot Water Piping Load 0 0 ;; „
MfiNUFIL 1
Winter Humidification Load 0 0 "mow
Infiltration 815 98 94
Approved ACCA
Ventilation 361 145 139 MJ8 Calculations
Duct Loss/Gain 215 153 97
AED Excursion n/a n/a n/a
Subtotal 4317 5857 1504
Total Heating 4317 Btuh
Total Cooling 7361 Btuh 9 Linear ft. of Hydronic Baseboard
0.53 Nominal Tons of Sensible Cooling 0.61 Nominal Tons of Total Cooling
*Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA. All computed calculations are
estimates based on building use,weather data, and inputted values such as R-Values,window types, duct loss, etc.
Equipment selection should meet both the latent and sensible gain as well as building heat loss.
Adtek AccuLoad Report Version 17.4.0 Page 5
•
• •
• :
• .
. .
%1110
•
A7,n45: . . . .„_ .
_ .
714,0 . :0J •
. 1•,,,ArtRri
7'!f-f:77;1 Ur
FW Webb Company Houde HVAC
108 Breeds Hill Rd -Hyannis, Ma 02601
508 775 3890 -
Sales Consultant:
Job#: 33 Cranberry Lane
Date: 08/23/2022
New Family Room (Peak Load Procedure)
Design Conditions
Location: Barnstable, Massachusetts Elevation: 30 ft Daily Range: Medium
Input Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 42° N Design Grains: 28
Summer: 88 70 Heated Area 400 Sq.Ft.
Winter: 12 74 Cooled Area 400 Sq.Ft.
Heat/Loss Summary (July Heat Load Calculations)
Gross Sensible Latent
Area Loss Gain Gain
Walls 472 1429 469 0
Windows 117.45 2402 3878 0
Doors 0 0 0 0
Ceilings 0 0 0 0
Skylights 0 0 0 0
Floors 425 727 242 0
Room Internal Loads 0 4334 800
Blower Load 662 819 0 „,M
Hot Water Piping Load 0 0 ,,,
nnx.
umor
Winter Humidification Load 0 0
Infiltration 1299 157 151
Approved ACCA
Ventilation 629 238 228 MJ8 Calculations
Duct Loss/Gain 375 251 160
AED Excursion n/a n/a n/a
Subtotal 7523 10388 1339
Total Heating 7523 Btuh
Total Cooling 11727 Btuh 16 Linear ft. of Hydronic Baseboard
0.94 Nominal Tons of Sensible Cooling 0.98 Nominal Tons of Total Cooling
*Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA.All computed calculations are
estimates based on building use, weather data, and inputted values such as R-Values, window types, duct loss, etc.
Equipment selection should meet both the latent and sensible gain as well as building heat loss.
Adtek AccuLoad Report Version 17.4.0 Page 6
1
T
FW Webb Company Houde HVAC
108 Breeds Hill Rd -Hyannis, Ma 02601
508 775 3890 -
Sales Consultant:
Job#: 33 Cranberry Lane
Date: 08/23/2022
Loft (Peak Load Procedure)
Design Conditions
Location: Barnstable, Massachusetts Elevation: 30 ft Daily Range: Medium
Input Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 42° N Design Grains: 28
Summer: 88 70 Heated Area 675 Sq.Ft.
Winter: 12 74 Cooled Area 675 Sq.Ft.
Heat/Loss Summary (July Heat Load Calculations)
Gross Sensible Latent
Area Loss Gain Gain
Walls 756 2972 972 0
Windows 18.69 382 448 0
Doors 0 0 0 0
Ceilings 675 1223 531 0
Skylights 0 0 0 0
Floors 675 0 0 0
Room Internal Loads 0 1681 400
Blower Load 753 389 0 n..b
Hot Water Piping Load 0 0 _ ;
MHNURL d
Winter Humidification Load 0 0
Infiltration 2080 251 241
Approved ACCA
Ventilation 715 113 108 MJ8 Calculations
Duct Loss/Gain 426 119 76
AED Excursion n/a n/a n/a
Subtotal 8551 4504 825
Total Heating 8551 Btuh
Total Cooling 5329 Btuh 18 Linear ft. of Hydronic Baseboard
0.41 Nominal Tons of Sensible Cooling 0.44 Nominal Tons of Total Cooling
*Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA.All computed calculations are
estimates based on building use, weather data, and inputted values such as R-Values, window types, duct loss, etc.
Equipment selection should meet both the latent and sensible gain as well as building heat loss.
Adtek AccuLoad Report Version 17.4.0 Page 7