Loading...
HomeMy WebLinkAboutUntitled INSURANCE COVERAGE: I have a current liability insura e policy or its equivalent which meets the requirements of M.G.L. Ch. 112 Yes ✓No If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy ✓Other type of indemnity Bond OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws, and that my signature on this permit application waives this requirement. Check One Only Owner Agent Signature of Owner or Owner's Agent By checking here ,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installation performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Inspections shall be called for prior to insulation installation. Duct inspection required prior to insulation installation: Yes No Date: Comments: Date: Comments: Type f license: V...4e By: Master Title: Master-Restricted Sig to of Licensee '1` City/Town: Journeyperson Permit#: Journeyperson-Restricted License Number: 9/6 Fee: $ � Check at www.mass.gov/dpl Inspector Signature of Permit T of Permit Approval AGHUSETTS"' °RCEED E • ``• :NOT FOR FEDERAL IDMIMBE . tia 0911312020 S 191 951901 CtAS' "' I28I2o25 0812811954 = D s EST NONE ?GREGORY J ry73LAFRANCEAVE HYANNIS,MA 02601.2432 , EYE6 BLu • 08128154 sex M • i NOT 5�10" • DD 0911412t 2O Rev 0212712016 • • DO pROF ;r "MONW ALTH O VI S ION OF S '`�lUENSIE RE,EIO LICSU BiOMBSSNAL pF SHEET MB1'AL YvuR�"RS; ISSUES T..HE FOLLO �� WING LICENSE A51 ER- UNRESTRICTED GR EGORY J HOUDE 73LAF • �NCEAIIE � ,. HYANNIS 14{A O26n1-2432 a„ W LICENSE NUMBER ° 202 11275$ EXNIRA7IUN DATE SERIAL NUMBER • • • • • • FW Webb Company Houde HVAC 108 Breeds Hill Rd -Hyannis, Ma 02601 Based on provided plans 508 775 3890 - Sales Consultant: `� Job#: 33 Cranberry Lane Date: 08/23/2022 System I (Average Load Procedure) Design Conditions Location: Barnstable, Massachusetts Elevation: 30 ft Daily Range: Medium Input Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 42° N Design Grains: 28 Summer: 88 70 Heated Area 1361 Sq.Ft. Winter: 12 74 Cooled Area 1361 Sq.Ft. Heat/Loss Summary (July Heat Load Calculations) Gross Sensible Latent Area Loss Gain Gain Walls 1524 5401 1768 0 Windows 164.175 3357 3998 0 Doors 20.01 484 242 0 Ceilings 675 1223 531 0 Skylights 0 0 0 0 Floors 1386 1216 405 0 .� Room Internal Loads 0 8935 2373 Blower Load 1707 0 nw�. Hot Water Piping Load 0 0 0 , , nnNRY Winter Humidification Load 1795 0 0 Infiltration 4194 506 486 Approved ACCA Ventilation 1705 495 476 MJ8 Calculations Duct Loss/Gain EHLF=0 ESGF=0 1016 524 333 AED Excursion n/a 0 n/a Subtotal 20391 19111 3668 Total Heating 20391 Btuh Total Cooling 22779 Btuh 41 Linear ft. of Hydronic Baseboard 1.74 Nominal Tons of Sensible Cooling 1.9 Nominal Tons of Total Cookrg, AHRI �,/ Friedrich Reference System High Heat Low Heat Model Number Indoor Type Capacity EER SEER 47 °F HSPF 17°F 204101247 Non-ducted Indoor Units 32000 12.50 21.00 36000 11.00 23200 FPHMR36A3A 203996910 Ducted Indoor Urits 32000 12.00 19.50 36000 10.80 22600 203999080 Mixed Ducted and Non-ducted 32000 12.25 20.25 36000 10.90 22600 Indoor Units :L Adtek AccuLoad Report Version 17.4.0 Page 1 L L/ FW Webb Company Houde HVAC 108 Breeds Hill Rd -Hyannis, Ma 02601 508 775 3890 - Sales Consultant: Job#: 33 Cranberry Lane Date: 08/23/2022 System I Load Chart Heat Loss Percentages Walls 5% Windows&Skylights 8% 26% M Doors Ceilings 21% Floors Misc System Loss II Infiltration 16% III Ventilation 9% 6% 6%2% Duct Loss Heat Gain Percentages Walls 5% 4% 8% Windows&Skylights 5% Doors 19% Ceilings Floors "�•. 1% Internal Gains 3% 2% U Infiltration 111 Ventilation 54% Duct Loss Adtek AccuLoad Report Version 17.4.0 Page 2 •.J \../ \..1 FW Webb Company Houde HVAC 108 Breeds Hill Rd -Hyannis, Ma 02601 508 775 3890 - Sales Consultant: Job#: 33 Cranberry Lane Date: 08/23/2022 Zone 1 1st Floor New Addition (Peak Load Procedure) Design Conditions Location: Barnstable, Massachusetts Elevation: 30 ft Daily Range: Medium Input Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 42° N Design Grains: 28 Summer: 88 70 Heated Area 686 Sq.Ft. Winter: 12 74 Cooled Area 686 Sq.Ft. Heat/Loss Summary (July Heat Load Calculations) Gross Sensible Latent Area Loss Gain Gain Walls 768 2429 796 0 Windows 145.485 2975 5188 0 Doors 20.01 484 242 0 Ceilings 0 0 0 0 Skylights 0 0 0 0 Floors 711 1216 405 0 --. Room Internal Loads 0 7254 1973 Blower Load 1318 Rmtt Hot Water Piping Load 0 0 „ Winter Humidification Load 0 0 Infiltration 2114 255 245 Approved ACCA Ventilation 990 383 367 MJ8 Calculations Duct Loss/Gain 590 404 257 AED Excursion n/a n/a n/a Subtotal 11840 16245 2843 Total Heating 11840 Btuh Total Cooling 19088 Btuh 24 Linear ft. of Hydronic Baseboard 1.48 Nominal Tons of Sensible Cooling 1.59 Nominal Tons of Total Cooling *Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA.All computed calculations are estimates based on building use,weather data, and inputted values such as R-Values, window types, duct loss, etc. Equipment selection should meet both the latent and sensible gain as well as building heat loss. Adtek AccuLoad Report Version 17.4.0 Page 3 FW Webb Company Houde HVAC 108 Breeds Hill Rd -Hyannis, Ma 02601 508 775 3890 - Sales Consultant: Job#: 33 Cranberry Lane Date: 08/23/2022 Zone 2 2nd Floor Loft (Peak Load Procedure) Design Conditions Location: Barnstable, Massachusetts Elevation: 30 ft Daily Range: Medium Input Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 42° N Design Grains: 28 Summer: 88 70 Heated Area 675 Sq.Ft. Winter: 12 74 Cooled Area 675 Sq.Ft. Heat/Loss Summary (July Heat Load Calculations) Gross Sensible Latent Area Loss Gain Gain Walls 756 2972 972 0 Windows 18.69 382 448 0 Doors 0 0 0 0 Ceilings 675 1223 531 0 Skylights 0 0 0 0 Floors 675 0 0 0 Room Internal Loads 0 1681 400 Blower Load 389 Iluzl,M Hot Water Piping Load 0 0 "N ; Winter Humidification Load 0 0 Infiltration 2080 251 241 Approved ACCA Ventilation 715 113 108 MJ8 Calculations Duct Loss/Gain 426 119 76 AED Excursion n/a n/a n/a Subtotal 8551 4504 825 Total Heating 8551 Btuh Total Cooling 5329 Btuh 18 Linear ft. of Hydronic Baseboard 0.41 Nominal Tons of Sensible Cooling 0.44 Nominal Tons of Total Cooling *Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA.All computed calculations are estimates based on building use, weather data, and inputted values such as R-Values, window types, duct loss, etc. Equipment selection should meet both the latent and sensible gain as well as building heat loss. Adtek AccuLoad Report Version 17.4.0 Page 4 v II v FW Webb Company Houde HVAC 108 Breeds Hill Rd -Hyannis, Ma 02601 508 775 3890 - Sales Consultant: `-- Job#: 33 Cranberry Lane Date: 08/23/2022 Kitchen (Peak Load Procedure) Design Conditions Location: Barnstable, Massachusetts Elevation: 30 ft Daily Range: Medium Input Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 42° N Design Grains: 28 Summer: 88 70 Heated Area 286 Sq.Ft. Winter: 12 74 Cooled Area 286 Sq.Ft. Heat/Loss Summary (July Heat Load Calculations) Gross Sensible Latent Area Loss Gain Gain Walls 296 1000 327 0 Windows 28.035 573 1310 0 Doors 20.01 484 242 0 Ceilings 0 0 0 0 Skylights 0 0 0 0 Floors 286 489 163 0 Room Internal Loads 0 2920 1173 Blower Load 380 499 0 Hot Water Piping Load 0 0 ;; „ MfiNUFIL 1 Winter Humidification Load 0 0 "mow Infiltration 815 98 94 Approved ACCA Ventilation 361 145 139 MJ8 Calculations Duct Loss/Gain 215 153 97 AED Excursion n/a n/a n/a Subtotal 4317 5857 1504 Total Heating 4317 Btuh Total Cooling 7361 Btuh 9 Linear ft. of Hydronic Baseboard 0.53 Nominal Tons of Sensible Cooling 0.61 Nominal Tons of Total Cooling *Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA. All computed calculations are estimates based on building use,weather data, and inputted values such as R-Values,window types, duct loss, etc. Equipment selection should meet both the latent and sensible gain as well as building heat loss. Adtek AccuLoad Report Version 17.4.0 Page 5 • • • • : • . . . %1110 • A7,n45: . . . .„_ . _ . 714,0 . :0J • . 1•,,,ArtRri 7'!f-f:77;1 Ur FW Webb Company Houde HVAC 108 Breeds Hill Rd -Hyannis, Ma 02601 508 775 3890 - Sales Consultant: Job#: 33 Cranberry Lane Date: 08/23/2022 New Family Room (Peak Load Procedure) Design Conditions Location: Barnstable, Massachusetts Elevation: 30 ft Daily Range: Medium Input Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 42° N Design Grains: 28 Summer: 88 70 Heated Area 400 Sq.Ft. Winter: 12 74 Cooled Area 400 Sq.Ft. Heat/Loss Summary (July Heat Load Calculations) Gross Sensible Latent Area Loss Gain Gain Walls 472 1429 469 0 Windows 117.45 2402 3878 0 Doors 0 0 0 0 Ceilings 0 0 0 0 Skylights 0 0 0 0 Floors 425 727 242 0 Room Internal Loads 0 4334 800 Blower Load 662 819 0 „,M Hot Water Piping Load 0 0 ,,, nnx. umor Winter Humidification Load 0 0 Infiltration 1299 157 151 Approved ACCA Ventilation 629 238 228 MJ8 Calculations Duct Loss/Gain 375 251 160 AED Excursion n/a n/a n/a Subtotal 7523 10388 1339 Total Heating 7523 Btuh Total Cooling 11727 Btuh 16 Linear ft. of Hydronic Baseboard 0.94 Nominal Tons of Sensible Cooling 0.98 Nominal Tons of Total Cooling *Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA.All computed calculations are estimates based on building use, weather data, and inputted values such as R-Values, window types, duct loss, etc. Equipment selection should meet both the latent and sensible gain as well as building heat loss. Adtek AccuLoad Report Version 17.4.0 Page 6 1 T FW Webb Company Houde HVAC 108 Breeds Hill Rd -Hyannis, Ma 02601 508 775 3890 - Sales Consultant: Job#: 33 Cranberry Lane Date: 08/23/2022 Loft (Peak Load Procedure) Design Conditions Location: Barnstable, Massachusetts Elevation: 30 ft Daily Range: Medium Input Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 42° N Design Grains: 28 Summer: 88 70 Heated Area 675 Sq.Ft. Winter: 12 74 Cooled Area 675 Sq.Ft. Heat/Loss Summary (July Heat Load Calculations) Gross Sensible Latent Area Loss Gain Gain Walls 756 2972 972 0 Windows 18.69 382 448 0 Doors 0 0 0 0 Ceilings 675 1223 531 0 Skylights 0 0 0 0 Floors 675 0 0 0 Room Internal Loads 0 1681 400 Blower Load 753 389 0 n..b Hot Water Piping Load 0 0 _ ; MHNURL d Winter Humidification Load 0 0 Infiltration 2080 251 241 Approved ACCA Ventilation 715 113 108 MJ8 Calculations Duct Loss/Gain 426 119 76 AED Excursion n/a n/a n/a Subtotal 8551 4504 825 Total Heating 8551 Btuh Total Cooling 5329 Btuh 18 Linear ft. of Hydronic Baseboard 0.41 Nominal Tons of Sensible Cooling 0.44 Nominal Tons of Total Cooling *Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA.All computed calculations are estimates based on building use, weather data, and inputted values such as R-Values, window types, duct loss, etc. Equipment selection should meet both the latent and sensible gain as well as building heat loss. Adtek AccuLoad Report Version 17.4.0 Page 7 Ewa'' � \ Op bre , HPfl r:i; rsys.t- F ‘ , h -7 erms S itifi Op,'" 70 Wreiy N49 &