Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD-23-000561
rislze • ONE & TWO FAMILY ONLY- BUILDING PERMIT Town of Yarmouth Building Department 1146 Route 28, South Yarmouth,MA 02664-4492 508-398-2231 ext. 1261 Fax 508-398-0836 Massachusetts State Building Code,780 CMR Building Permit Application To Construct, Repair, Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only RECEIVED Building Permit Number: S t , 3 QOd Sip I- .Date Applied: . JUL 9 2022 Build Official(Print Name) Signature pARTMENT SECTION 1:SITE INFORMATION nv nt1tLDtP1G DE 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 11 Macomber Drive,Yarmouth,MA 02675 1.1 a Is this an accepted street?yes no Map Number Parcel Number 1. a mol °iformation: PV Solar 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private❑ Zone: _ Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP'. 2.1 Owner'of Record: Yarmouth,MA 02675 Diane Seigal Name(Print) City,State,ZIP 11 Macomber Drive 508-776-7383 beyondthebeachcapecod@gmail.com No.and Street Telephone Email Address SECTION3:DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction❑ Existing Building❑ Owner-Occupied 0 Repairs(s) 0 Alteration(s) El Addition ❑ Demolition 0 Accessory Bldg.❑ Number of Units Other 1R Specify: PV Solar Brief Description of Proposed Work': Installation of a safe and code compliant,grid-tied PV solar system on an existing residential rooLU Panel/3.96 kW e. lir I it.r)p,'11 i ion- iZ a - SECTION.4i ESTIMATED CONSTRUCTION COSTS. Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building $ 3,000 1.. Building Permit Feed$ 7 Indicate how fee is determined: 2.Electrical $ 11,000 0 Standard City/Town Application Fee 0 Total Project Cost'(Item 6)x multiplier x 3.Plumbing $ 0 2; Other Fees: $ n 4.Mechanical (HVAC) $ 0 List: :- 5.Mechanical (Fire Suppression) $ 0 Total All Fees: Check No. Check Amount: Cash Amount: 14,000 6.Total Project Cost: $ 0 Paid in Full 0 Outstanding Balance Due: SECTION 5:.CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-027047 Phil Chouinard. License Number Expiration Date Name of CSL Holder 95 Ryan Dr. Suite 3 List CSL Type(see below) No,and Street Type Description Raynham, MA 02767 U Unrestricted(Buildings up to 35,000 cu.ft.) R Restricted l&2 Famil Dwellin City/Town,State,ZIP M Maso RC Roofin Coverin WS Window and Sidin SIF Solid Fuel BumingAppliances (732) 354-3111 permits@skylinesolar.net Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 172284 Skyline Solar LLC. HIC Registration Number Expiration Date HIC CQpa iy N �r 11.1C Suitegistrant Name 95Hyanpermits@skylinesolar.net and trees Email address -iayn am, MA 02767 (732) 354-3111 City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes 0 No 0 SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT .. I,as Owner of the subject property,hereby authorize Skyline Solar LLC to act on my behalf,in all matters relative to work authorized by this building permit application. Diane Seigal b%4nce-SE6ja,,ri 7/26/2022 Print Owner's Name(Electronic Signature) Date •SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application and accurate to the best of my knowledge and understanding. Phil Chouinard i")Z4g eZo`G z;te zZ 7/26/2022 Print Owner's or_thorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.eov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms _ Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" • RECEIVE `Y^" TOWN OF YARMOUTH v- 1146 ROUTE 28, SOUTH YARMOUTH. MA 02664-4451 Telephone(508)398-2231 Ext 1292-Fax(508)398-0836 AUG 2OLD KI G'S HIGHWAY HISTORIC DISTRICT COMM ITTEE 'ARMOuTI-. OLD KINGS HIGHWAY l APPLICATION FOR CERTIFICATE OF APPROPRIATENESS Application is hereby made for issuance of a Certificate of Appropriateness under Section 6 of Chapter 470. Acts of 1973 as amended, for proposed work as described below&on plans. drawings. photographs. &other supplemental info accompanying this application PLEASE SUBMIT 4 copies OF SPEC SHEET(S), ELEVATIONS PHOTOS,&SUPPLEMENTAL INFORMATION. Check All Categories That Appl : Indicate type of Building: Commercial 7 Residential 1)Exterior BuildA Construction: 'New Building Addition Iterations Reroof I 1Garage Shed Solar Panels !Other: 2)Exterior Painting: Siding Shutters ; Doors Trim LiOther. 3)Signs/Billboards: New Sign Change to Existing Sign 4)Miscellaneous Structures: Fence II !Wall 11Flagpole Pool Other: Please type or print legibly: �/ M 1 d, Address of proposed work 1\ �kLorn�,t-1 br-- Cs(�n,r„W,1 I lA � O 5 _Map/Lot# 136 / A Owner(s) j .k.nri- , ;qa i Phone#. (Sag) 7✓.,- 7 l Q All applications Imust be submitted by owner or accompanied by letter from owner approving submittal of application. Mailing address: I'1I 1 l kce,ey, - II .Dr, ' )„avi,,c,.14,, 1A C�).h 7 5 Year built: I Y 7 6 Email beyl;nd 1'),� bo,p(h n po.Cr i P�Q�v l,Lo� Preferred notification method I .. Phone U Email Agent/contractor. $j>) I D�-,I� / JJS i.;y 1 ,n p SD t u r- 1 1-� , Phone#. (73�)3 S y-3i I I Mailing Address 15 a A rbr. S u,k -) R,A I n k,trr, /v I A\ G 2 7 6 7 y r Email -,,,; S�r(,„Qur, r)L 4Ell Lr,- Preferred notification method: Phone Email Description oUProposed Work: 5t4.11 a rt of 4 SApe end CD rC\e Co ((ioil l'1 y t o!e 4 eid f / Sal kr O ysk ,�1 'r, o, ek;s1-;-y re3;40-i.,1 root. II Pv cds / 3, 76 a �): Signed(Owner or agent) / j,,, /}. -- r Date ,4/ / 7/ as Owner/contractor/agent is aware that a permit is required from the Building Department (Check other departments also If application is approved.approval is subject to a 10-day appeal period required by the Act This certificate is good for one year from approval date or upon date of expiration of Building Permit whichever date shall be later All new construction will be subject to inspection by OKH OKH-approved plans MUST be available on-site for framing&final inspections / For Committee use only: Approved Approved with Modifications Denied Rcvd Date y(.294aP` Reason for Denial_ - Amount `IU•LA- me 'LOVED Cash/CK# (06.- Rcvd by Li �. Signed /��.. . ,,,,,�r,� SFP 1 2 71172 46Days: )i,,:rt Date Signed: � f / ' Z. 1 '/i2 APPLICATION# Q Commonwealth of Massachusetts Division of Professional Licensure Board of Building Re ulations and Standards Coat CS-027047 4' • spires 11/09/2023 PHILIP J cHoot 79 OAK ST. ,IT'i t ASHLAND r 1 ) Ill Commissioner I HE C.;UMMUNVVEHL I H UI- MA55AL HUSt 115 Office of Consumer Affairs and Business Regulation 1000 Washington Street - Suite 710 Boston, Massachusetts 02118 Home Improvement Contractor Registration 3. ,- .. tt }d Type: Supplement Card O Registration: 172284 SKYLINE SOLAR, LLC. r" = , Expiration: 06/06/2024 4 CROSSROADS DRIVE SUITE 116 ,..... I Tri . HAMILTON, NJ 08691 ": 4 7,• Update Address and Return Card. THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs&Business Regulation Registration valid for individual use only before the HOME IMPROVEMENT CONTRACTOR expiration date. If found return to: TYPE:Supplement Card Office of Consumer Affairs and Business Regulation Registration Expiration 1000 Washington Street -Suite 710 172284 06/06/2024 Boston, MA 02118 .KYLINE SOLAR. LLC. HILIP CHOUINARD (--/ CROSSROADS DRIVE SUITE 116 .,�P��,,f� i k' -Q)A-1 IAMILTON, NJ 08691 Undersecretary Not valid without signature Aco OR ® CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDDIYYYY) `.------ 1/31/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Hub International Northeast NAME: Chrysanthia Orr FAX 5 Bryant Park a/CC.N No.Extl:212-338-2214 (A/c,No):866-863-1037 4th Floor E-MAIL ADDRESS: Chrysanthia.Orr@hubinternational.com New York NY 10018 INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:Gotham Insurance Company 25569 INSURED SKYLSOL-04 INSURER B:Selective Ins.Co.of the Southeast 39926 Skyline Solar, LLC Skyline Solar RI, Inc. INSURER C:Berkley Casualty Company 15911 191 Godwin Avenue#1 INSURER D:Selective Way Insurance Company 26301 Wyckoff NJ 07481-5201 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:398540480 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP LTR INSD WVD POLICY NUMBER (MM/DDIYYYY) (MMIDDIYYYY) LIMITS A X COMMERCIAL GENERAL LIABILITY PK202100009640 1/30/2022 5/30/2023 EACH OCCURRENCE $1,000,000 CLAIMS-MADE X OCCUR DAMAGE TO RENTED PREMISES(Ea occurrence) $100,000 MED EXP(Any one person) $5,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 POLICY X jE LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER: $ B AUTOMOBILE LIABILITY A 9093050 1/30/2022 5/30/2023 COMBINED SINGLE LIMIT $1,000,000 D S 2312421 (Ea accident) X ANY AUTO 1/30/2022 5/30/2023 BODILY INJURY(Per person) $ OWNED SCHEDULED BODILYINJURY(Per $ AUTOS ONLY AUTOSaccident) X HIRED x NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY (Per accident) _ S A X UMBRELLA LIAB X OCCUR EX202100001772 1/30/2022 5/30/2023 EACH OCCURRENCE $1,000,000 EXCESS LIAB CLAIMS-MADE AGGREGATE $1,000,000 DED RETENTION$ $ C WORKERS COMPENSATION BNUWC0156055 1/30/2022 1/30/2023 X PER OTH- ANDEMPLOYERS'LIABILITY Y/N STATUTE ER ANYPROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $1,000,000 OFFICER/MEMBEREXCLUDED? n N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $1,000,000 If yes describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $1,000,000 A Professional Liability E&O PK202100009640 1/30/2022 5/30/2023 Each Wrongful Act. 2,000,000 Aggregate 2,000,000 DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) EVIDENCE OF INSURANCE CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. EVIDENCE OF INSURANCE AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts _.._ate Department of Industrial Accidents fr) Office of Investigations =,�I'i Lafayette City Center _.:4 15�` 2 Avenue de Lafayette, Boston, MA 02111-1750 ,,. www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Skyline Solar LLC. Address: 95 Ryan Dr. Suite 3 City/State/Zip: Raynham, MA 02767 Phone #: (732) 354-3111 Are you an employer? Check the appropriate box: Type of project(required): 1.111 4.I am a employer with 85 ❑ I am a general contractor and I 6. ❑New construction employees (full and/or part-time).* have hired the sub-contractors listed on the attached sheet. 7. ❑ Remodeling 2.❑ I am a sole proprietor or partner- ship and have no employees These sub-contractors have 8. ❑ Demolition workingfor me in anycapacity. employees and have workers' P ty. 9. ❑ Building addition [No workers' comp. insurance comp. insurance. required.] 5. ElWe are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.1::] Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152, §1(4),and we have no 13.® OtherPV Solar System employees. [No workers' comp. insurance required.] *My applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. Iam an employer that is providing workers'compensation insurance for my employees. Below is the policy and.job site information. Insurance Company Name: Berkley Casualty Company Policy#lor Self-ins. Lic. #: BNUWC0156055 Expiration Date: 1/30/23 Job Site Address: 11 Macomber Drive City/j Late/Zip: Yarmouth, MA 02675 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and pe lties of perjury that the information provided above is true and correct. Signature: ) b&tM$ €_ Date: 07/26/2022 Phone#: 732-354-3111 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License # Issuing Authority(check one): 11=1Board of Health 20 Building Department 30City/Town Clerk 4.0 Electrical Inspector 50Plumbino Inspector 6.0Other Contact Person: Phone#: THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs and Business Regulation 1000 Washington Street - Suite 710 Boston, Massachusetts 09118 Home Improvement Contractor Registration L"�Z '" _ Type: Out of State Corporation '�s Registration: 172284 SKYLINE SOLAR, LLC. Poi[ Expiration: 06/06/2024 4 CROSSROADS DRIVE SUITE 116 �. ,_ HAMILTON, NJ 08691 r. \l : _ f Update Address and Return Card. THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs&Business Regulation Registration valid for individual use only before the HOME IMPROVEMENT CONTRACTOR expiration date. If found return to: TYPE:Out of State Corporation Office of Consumer Affairs and Business Regulation Registration Expiration 1000 Washington Street -Suite 710 172284 06/06/2024 Boston, MA 02118 .KYLINE SOLAR,LLC. ;ILL DAILEY CROSSROADS DRIVE SUITE 116 7 LCM"""./IOW •/Y�iN�t W `I IAMILTON,NJ 08691 Undersecretary Not valid withou signature OF eYA TOWN OF YARMOUTH o _µ yhy= BUILDING DEPARTMENT 1146 Route 28, South Yarmouth,MA 02664 508-398-2231 ext. 1261 HOMEOWNER LICENSE EXEMPTION PLEASE PRINT: DATE: 7/26/2022 JOB LOCATION: 11 Macomber Drive,Yarmouth,MA 02675 NAME STREET ADDRESS SECTION OF TOWN "HOMEOWNER" Diane Seigal 508-776-7383 508-776-7383 NAME HOME PHONE WORK PHONE PRESENT MAILING ADDRESS 11 Macomber Drive,Yarmouth,MA 02675 CITY OR TOWN STATE ZIP CODE The current exemption for `Homeowner' was extended to include owner—occupied dwellings of one or two units and to allow such homeowners to engage an individual for hire who does not possess a license,provided that such homeowner shall act as supervisor. (State Building Code Section 110 R5.1.3.1) Definition of Homeowner: Person(s)who owns a parcel of land on which he/she resides or intends to reside,on which there is or is intended to be, a one or two family attached or detached structure assessory to such use and I or farm structures. A person who constructs more than one home in a two-year period shall not be considered a homeowner;such"homeowner"shall submit to the building official,on a form acceptable to the building official,that he/she shall be responsible for all such work performed under the buildinv permit. (Section 110 R5.1.3.1) The undersigned `homeowner' assumes responsibility for compliance with the State Building Code and other applicable codes,by-laws,rules and regulations. The undersigned 'homeowner' certifies that he/ she understands the Town of Yarmouth Building Department minimum inspection procedures and requirements and that he I she will comply with said procedures and requirements. HOMEOWNER"S SIGNATURE b -Se-c:/a,G APPROVAL OF BUILDING OFFICIAL INSURANCE COVERAGE: I have a current liability insurance policy or its substantial equivalent, which meets the requirements of MGL Ch.142. Yes No If you have checked yes,please indicate the type coverage by checking the appropriate box. A liability insurance policy Other type of indemnity Bond OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 142 of the Mass. General Laws and that my signature on this permit application waives this requirement. eAeUua;a ,d Check one: Signature of Owner or Owner's Agent Owner Agent) h:homeownrlicexemp •Y TOWN OF YARMOUTH _ r _ o BUILDING M NT Y _� g $ 1146 Rou• te 23, SouthDEPART Yarmouth,l�IA 02664 5_ 508-398-2231 ext. 1261 Fax 508-398-0836 BUILDING DEPARTMENT DEMOLITION DEBRIS DISPOSAL AFFIDAVIT Pursuant to M.G.L Chapter 40,Section 54 and 780 CMR, Chapter 1, Section 111.5, I hereby certify that the debris resulting from the proposed work/demolition to be conducted at 11 Macomber Drive,YarmOuh.MA 07675 Work Address E.O.M.S - 318 Manley St. West Bridgewater, MA 02379 Is to be disposed of at the following location: Said disposal site shall be a licensed solid waste facility as defined by NM.G.L. Chapter 111, Section 150A. P 7/26/2022 Signature of Application Date CS 027D4-7 Permit No. DEBRIS DISPOSAL AFFIDAVIT In accordance with the provisions of M.G.L. c. 40, s. 54, Building Permit # was issued with the condition that all debris resulting from this work shall be disposed of in a properly licensed solid waste disposal facility as defined by M.G.L c. 111, s. 150A. The debris will be disposed of in: E.O.M.S Name of Waste Facility 318 Manley St. West Bridgewater, MA 02379 Address of Waste Facility 111.5 Debris: As a condition of issuing a permit for the demolition, renovation, rehabilitation or other alteration of a building or structure, M.G.L. c. 40 s. 54 requires that the debris resulting therefrom shall be disposed of in a properly licensed solid waste disposal facility as defined by M.G L.c. 1 I 1 s. 150 A.Signature of the permit applicant, date and number of the building permit to be issued shall be indicated on a form provided by the Building Department and attached to the office copy of the building permit retained by the Building Department. If the debris will not be disposed of as indicated, the holder of the permit shall notify the building official, in writing,as to the location where the debris will be disposed. 780 CMR-6th Edition deigf Permit Applicant 06/01/2022 Date ,VVYSSLING CONSULTING �•�•,..._.. .�..,� ••.,_, .•.. 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Jon P. Ward, SE, PE office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com June 30, 2022 Revised July 21, 2022 Skyline Solar 4 Crossroads Drive, Suite 116 Hamilton, NJ 08691 Re: Engineering Services Seigel Residence 11 Macomber Drive, Yarmouth Port, MA 5.760 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: 2x8 dimensional lumber at 16"on center. Roof Material: Composite Asphalt Shingles Roof Slope: 34 and 35 degrees Attic Access: Accessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing =7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 PSF • Live Load = 20 psf(reducible)—0 psf at locations of solar panels • Ground Snow Load = 30 psf • Wind Load based on ASCE 7-10 o Ultimate Wind Speed = 141 mph (based on Risk Category II) o Exposure Category B Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2015 International Residential Code, including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105%for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent Unirac installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a 5/16" lag screw is 235 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 2'%", the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using one 5/16" diameter lag screw with a minimum of 21/2" embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof,the panel supports shall be placed no greater than 64"on center. 4. Panel supports connections shall be staggered to distribute load to adjacent framing members. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2015 IRC, current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. V truly rs, Scott E.Wyssli , PE MA License No. 505 Q E10, o s 90�, FGigtEP FSSIONA. 1VTr$t: LT GG ABBREVIATIONS ELECTRICAL NOTES GENERAL NOTES INDEX A AMPERE 1. WHERE ALL TERMINALS OF THE 1. THIS SYSTEM IS GRID-INTERTIED VIA A UL-LISTED AC ALTERNATING CURRENT DISCONNECTING MEANS MAY BE POWER-CONDITIONING INVERTER. PV1 COVER SHEET BLDG BUILDING ENERGIZED IN THE OPEN POSITION,A 2. THIS SYSTEM HAS NO BATTERIES,NO UPS. PV2 SITE PLAN CONC CONCRETE SIGN WILL BE PROVIDED WARNING OF 3. ALL INVERTERS AND ARRAYS ARE NEGATIVELY C COMBINER BOX PV3 ARRAY DETAIL THE HAZARDS PER ART.690.17. GROUNDED. D DISTRIBUTION PANEL DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED. PV4 STRUCTURAL VIEWS EGC EQUIPMENT GROUNDING CONDUCTOR THE MULTIWIRE BRANCH CIRCUIT WILL (E) EXISTING BE IDENTIFIED BY PHASE AND SYSTEM PV5 ELECTRICAL DIAGRAM EMT ELECTRICAL METALLIC TUBING PER ART.210.5. GALV GALVANIZED 3. A NATIONALLY-RECOGNIZED TESTING VICINITY PV6 LABEL SET GEC GROUNDING ELECTRODE CONDUCTOR LABORATORY SHALL LIST ALL GPS LOCATION:41.7105073,-70.1903225 PV7 DIRECTORY PLACARD GND GROUND EQUIPMENT IN COMPLIANCE WITH ART. HOG HOT DIPPED GALVANIZED 110.3. APPLICABLE CODES I CURRENT 4. CIRCUITS OVER 250V TO GROUND SHALL 2015 IRC Imp CURRENT AT MAX POWER .s r'.OF 1r; COMPLY WITH ART. 250.97,250.92(B) '`" -2020 NEC I f�'' INVS INVERTERS 5. DC CONDUCTORS EITHER DO NOT ENTER Inc SHORT CIRCUIT CURRENT f' v,r_ , kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC 1 kW KILOWATT RACEWAYS OR ENCLOSURES TO THE - �' LBW LOAD BEARING WALL FIRST ACCESSIBLE DC DISCONNECTING I, ',. MIN MINIMUM MEANS PER ART.690.31(E). Signed 7/21/20 (N) NEW 6. ALL WIRES SHALL BE PROVIDED WITH NEC NATIONAL ELECTRIC CODE STRAIN RELIEF AT ALL ENTRY INTO 0"- AHJ: TOWN OF YARMOUTH BOXES AS REQUIRED BY UL LISTING. �`„_ " �'' '�` ` NIC NOT IN CONTRACT ' NTS NOT TO SCALE 7. MODULE FRAMES SHALL BE GROUNDED 1146 ROUTE 28 OC ON CENTER AT THE UL-LISTED LOCATION PROVIDED OW 7rvi SOUTH YARMOUTH,MA 02664 P PANEL BOARD ra BY THE MANUFACTURER USING UL ' `�.`+ ,6' „r (y1 (508)398-2231 PL PROPERTY LINES a ire' LISTED GROUNDING HARDWARE. PV PHOTOVOLTAIC 1 # . 0 PVC POLYVINYL CHLORIDE B. ALL EXPOSED METAL PARTS(MODULE vot 11 ;° UTILITY:EVERSOURCE FRAMES,RAIL,BOXES,ETC.)SHALL BE ♦ ' cc S SUBPANEL 11 Macomber Dr, c� SCH SCHEDULE GROUNDED USING UL LISTED LAY-IN i lip Yarmouth Port, MA... SS STAINLESS STEEL LUGS LISTED FOR THE PURPOSE.POSTS .,..�,, C) SSD SEE STRUCTURAL DIAGRAMS SHALL BE MADE ELECTRICALLY .... r r SKYLINE SOLAR STC STANDARD TESTING CONDITIONS CONTINUOUS WITH ATTACHED RAIL. s J SWH SOLAR WATER HEATER 9. MODULE FRAMES,RAIL,AND POSTS 4 CROSSROADS DR.SUITE 116 TYP TYPICAL SHALL BE BONDED WITH EQUIPMENT •° � HAMILTON,NJ 08691 UON UNLESS OTHERWISE NOTED GROUND CONDUCTORS AND GROUNDED it"� UPS UNINTERRUPTIBLE POWER SUPPLY LICENSES _ V VOLT AT THE MAIN ELECTRIC PANEL. Vmp VOLTAGE AT MAX POWER 10. THE DC GROUNDING ELECTRODE H IC: 172284 Voc VOLTAGE AT OPEN CIRCUIT CONDUCTOR SHALL BE SIZED - ELEC:21667-A W WATT ACCORDING TO ART.250.166(B)&690.47. CSL:CS-027047 3R NEMA 3R,RAIN TIGHT : aid iii MODULES: (11)HANWHA Q.PEAK DUO-G10+360W DIANE SEIGAL SEIGAL RESIDENCE JOB NUMBER: 203153 RAGE INVERTER: (11)ENPHASE IQ8PLUS-72-2-US[240V] 11 MACOMBER DR 3.96 kW DC ROOF SOLAR SYSTEM DESIGNED BY: RACKING: UNIRAC NXT UTILITY: EVERSOURCE YARMOUTH PORT,MA 02675,USA RV I SKYLINE OWNER- OESCRWRON SOLAR REV OATS: FLASHING: UNIRAC NXT MR Accra- (508)776-7383 AC SYSTEM SIZE:3.19 kWAC C 0720REO PAGE NAME: COVER SHEET • W E LEGEND M UTILITY METER 125'- � INV INVERTER 111 �Nof c� �, J�j �� Wes' �� ' ��� O � ; aci AC DISCONNECT N�� DRIVEWAY � /i 9?,,,,S ,4Q' / "-A`-�'�� MSP �� MAIN SERVICE PANEL > Signed 7/21/2022 x DETACH4°1 d B DC JUNCTION BOX l9� \;p ._,���S P MONITORING UNIT - ' r�.: 'A o ���ZE �'��� �����--, t, / j��� ��.1-) D DISTRIBUTION PANEL c ' ��-. LC LOAD CENTER c F L- ,.....) J. , No FENCE . a 1 \1 ' l'�`J'J J 6l (-r ) l. i. J _,- ��J d? O (( J error �- J ROOF COVERAGE TREES i L.,, `' , 223'-3' TOTAL ROOF AREA 937 ft2 TOTAL SYSTEM AREA 214.03 ft2 POOL ROOF COVERAGE 22.84% OWNER: DESEIGA PAGE. PV2 MODULES: (11)HANWHA Q.PEAK DUO-G10+360W JOB NUMBER: 203153 DIANE SEIGAL SEIGAL RESIDENCE INVERTER: (11)ENPHASE IQ8PLUS-72-2-US[240V] 11 MACOMBER DR 3.96 kW DC ROOF SOLAR SYSTEM DESIGNED BY:RV iiiii.114116 RACKING: UNIRAC NXT UTILITY: EVERSOURCE YARMOUTH PORT,MA 02675,USA SKYLINE®SOLAR FLASHING: UNIRAC NXT umm Accv:— (508)776-7383 AC SYSTEM SIZE:3.19 kWAC REV. C BAIT 07/20/2022 PARE NAME SITE PLAN • N LEGEND UTILITY METER w + ROOF 111111 RAFTERS -75'TRENCH RAIL _-CONDUIT 0 MOUNT ® OBSTRUCTION TOTAL PENETRATION COUNT 30 NON-FUSED AC DISCONNECT MPI RAFTER PROFILE 2"X8" LOAD CENTER (E)NON FUSED AC DISCONNECT RAFTER SPACING 16" (E)LOAD CENTER C.J.SPACING 16" ATTACHMENT •111 44 »oF SPACING(MAX) 64" (E)MA SMART METER y` ' so'` \ ROOF PITCH 34° ARRAY PITCH 34° CHIMNEY ��r I \` • '�ti A ROOF AZIMUTH 345° ©I "�'`31► �\ �� aF ors a��e ARRAY AZIMUTH 345° f, ` .mow 'ioNAL ENG ROOF SURFACE 4 1,...;.11rfr. -., ® �� TYPE COMP.SHINGLE V. „ �\j ' f Signed 7/21/2022 STORIES 2 . 4 � �' x MP2 �'° ',4/ RA. ER PROFILC 2"X8" MAIN SERVICE PANEI �,%`� / ` " RAFTER SPACING 16" by / / / A.,., JUNCTION BOX IC.J.SPACING 16" \vJ S / / / / \,* S� ATTACHMENT MP1 / / / �' + SPACING(MAX) 64" (6)MODULES • / // / '^ // k ��` / 7 j�L ROOF PITCH 35° �`\ / _��' ARRAY PITCH 35° / // / ' „ ROOF AZIMUTH 166° // /' - 1 ARRAY AZIMUTH 166° / r ROOF SURFACE ` / ` 0�► TYPECOMP.SHINGLE EXISTING SOLAR 404 :i STORIES 2 MP2 �I.' ROOF LEAD (5)MODULES SIGN OFF: own1 oesc96 k PAGE PV3 MODULES: (11)HANWHA Q.PEAK DUO-G10+360W DIANE SEIGAL N SEIGAL RESIDENCE JOB NUMBER:203153 INVERTER: (11)ENPHASE IQ8PLUS-72-2-US[240V] 11 MACOMBER DR 3.96 kW DC ROOF SOLAR SYSTEM '"REV: RV RACKING: UNIRAC NXT UTILITY: EVERSOURCE YARMOUTH PORT,MA 02675,USA SKYLINEA SOLAR unmuna:— (508)776-7383 AC SYSTEM SIZE:3.19 kWAC C DATE: nmozms PAGE Nam: ARRAY DETAIL FLASHING: UNIRAC NXT SOLAR MODULE_ 1111001111111111111 UNIRAC NXT RAN.--- STRONGHOLD ATTACHMENT KIT 1111 COMPOSITE SHINGLE I 5'%T}'-LAG / 2'%8-©16'ON CENTER STANDOFF - SCALE:Ni5 iox,,,-, ' i Sl TH OF 1 SC. ; , WY- L U\, ' �fi''-2'-:p ._.__ __- ---_..p7_7.__.---_._ _ _._.. ..._..._-__._• 1".....----._. ........__ -9'd' or,,.\crs oF, N / ".ONaL paw r---'\ MP2 SIDE VIEW NTS MP1 SIDE VIEW Signed 7/21/2022 RAFTER 1 XE"#1C O t;. 1 NTS (MAX SPAN 1�-7" _ ___. _—.—.( _— ROOF TYPE RAFTERS.Z7C8"@ 16"O.COMP SHINGLE .C. ROOF AGE' tic YEARS OLD} MAX SPAN.7'-7" ROOF CONDITION:GOOD ROOF TYPE COMP SHINGLE _...__--- ...---.......__. _..___....._........... ROOF AGE'. 5+YEARS OLD ROOF CONDITION:GOOD WN1N N 3.96 k. MODULES: (11)HANWHA O.PEAK DUO-G10+360W O DIANE SEIGAL SEIGAL RESIDENCE JOB NUMBER:203153 PAGE j���y" INVERTER: (11)ENPHASE IQ8PLUS-72-2-US[240V] 11 MACOMBER DR 3.96 kW DC ROOF SOLAR SYSTEM DESIGNED BY' RACKING: UNIRAC NXT UTILITY: EVERSOURCE YARMOUTH PORT,MA 02675,USA RV PV4 SKYLINE S LA FLASHING: UNIRAC NXT Ate.:— (508)776-7383 AC SYSTEM SIZE:3.19 kWAC C mna2022 PAGE NAME STRUCTURAL VIEWS ♦ BREAKER CONSUMPTION METERING IS REQUIRED -imE_ FUSE Main Service Panel Bus Rating = 200 A -----.- SWITCH Main Breaker Rating = 200 A EARTH GROUND 120/240V SINGLE PHASE ---— GEC UNDERGROUND MSP Maximum Allowable Backfeed = UTILITY SERVICE,,...--- ------ EGC BRANCH #of MODULES OPT CURRENT(A) BREAKER SIZE METER (A) . 02 925 799 BRANCH 1 11 13.31 20 \ 1 INVERTER MAX CONTINUOUS OUTPUT CURRENT(A)= 1.21 TOTAL BACKFEED(A)= 13.31 LOAD CENTER BACKFEED(A)= 20 z 1 2 w zoeazP 3 4 w _— (N)ENPHASE ENVOYS f COMBINER BOX a R (N)60A AC DISCONNECT MODEL#50D DU222R# -NON-FUSIBLE,LOCKABLE (N)EZ SOLAR JBI-XL (N)(11)HANWHA O.Peak Duo-G10+360W 360W PV MODULES 20A/2P JUNCTION BOX with(11)ENPHASE 10BPLUS-72-2-US 1240VI MICROINVERTERS 200A/2P -- ��-------.... — "- --------=----- 1 f" ------ 8/BRANCH ///^— - OF 11 ON MPi nLINE LOAD 11 % II 2 I I I O IE)LOADS ,I 1 I '1 11 1 0 i 1 t 15/2P n i 1 /- S (N)20A2P I r -�-� I POINT OF CONNECTION -----I BACKFED BREAKER ENPHASE ENVOY GROUNDING ELECTRODE Electrical Checked ok by MT WIRE SCHEDULE 2 3 4 ELEC. LEAD AWG#10,THWN-2 AWG#10,THWN-2 AWG#10,THWN-2 AWG#10,PV WIRE AWG#8,THWN-2,EGC/GEC AWG#8,THWN-2,EGC/GEC AWG#8,THWN-2,EGC/GEC AWG#6,THWN-2,EGC SIGN OFF: CONDUIT,3/4"EMT CONDUIT,3/4"EMT CONDUIT,3/4"EMT CONDUIT,3/4"EMT OWNER O3.NPIIDN PAGE p v 5 MODULES: (11)HANWHA O.PEAK DUO-G10+360W DIANE SEIGAL SEIGAL RESIDENCE JOB NUMBER:203153 iiiii4111INVERTER: (11)ENPHASE IOBPLUS-72-2-US[240V1 11 MACOMBER DR 3.96 kW DC ROOF SOLAR SYSTEM Deslcxen er 1 RACKING: UNIRAC NXT UTILITY: EVERSOURCE YARMOUTH PORT,MA 02675,USA REY RV �� SKYLINE®SOLAR FLASHING: UNIRAC NXT umnv ncct Y.— (508)776-7383 AC SYSTEM SIZE:3.19 kWAC C o7aa2#zz rAce NNAe. ELECTRICAL DIAGRAM NEC 690.5(C) NEC 690.31(2) PLACE THIS LABEL ON INVERTER(S)OR NEAR PLACE ON ALL JUNCTION BOXES,EXPOSED NEC 705.12(B)(3)(2) GROUND-FAULT INDICATOR(ON INVERTER(S)U.O.N.) RACEWAYS EVERY 10'AND 1'FROM BENDS AND PLACE THIS LABEL AT P.O.C.TO SERVICE NOTE: I PENETRATIONS,ADJACENT TO THE DISTRIBUTION EQUIPMENT(I.E.MAIN BACKGROUND AND LETTERING COLORS FOR SIGNAGE/LABELS MAIN SERVICE DISCONNECT PANEL(AND SHALL COMPLY WITH(IN ORDER OF PRIORITY)AHJ&FIRE WARNINGSUBPANEL IF APPLICABLE)) DEPARTMENT AMENDMENTS,STATE CODE,AND ANSI WARNING WARNING GUIDELINES.THIS PAGE IS INTENDED OR SIGNAGE/LABEL ELECTRICAL SHOCK HAZARD VERBIAGE ONLY. IF A GROUND FAULT IS INDICATED,NORMALLY GROUNDED CONDUCTORS MAY PHOTOVOLTAIC POWER INVERTER OUTPUT CONNECTION OUTSIDE LABELING OF SYSTEM COMPONENTS AND METERS IS BE UNGROUNDED AND ENERGIZED SOURCE DO NOT RELOCATE THIS OVERCURRENTDEVICE TO BE DONE IN A WAY SUITABLE FOR THE ENVIRONMENT IN WHICH THE EQUIPMENT IS INSTALLED.NO STICKERS ARE NEC 690.16(8) NEC 690.35(F) PERMITTED. PLACE THIS LABEL ON ALL DISCONNECTING PLACE THIS LABEL AT EACH JUNCTION BOX, NEC 705.12(C)AND NEC 690.59 MEANS WHERE ENERGIZED IN AN OPEN POSITION COMBINER BOX, PLACE THIS LABEL AT P.O.C.TO SERVICE DISCONNECT AND DEVICE WHERE ENERGIZED, DISTRIBUTION EQUIPMENT(I.E.MAIN 2020 NFPA 70,NEC 690.56(c) WARNINGUNGROUNDED PANEL(AND PLACE ON RAPID SHUTDOWN DISCONNECT WHEN RAPID CIRCUITS MAY BE EXPOSED DURING SERVICE: SUBPANEL IF APPLICABLE)) SHUTDOWN IS INSTALLED ELECTRICAL SHOCK HAZARD WARNING WARNING PHOTOVOLTAIC SYSTEM EQUIPPED DO NOT TOUCH TERMINALS WITH RAPID SHUTDOWN TERMINALS ON BOTH THE LINE AND LOAD DUAL POWER SOURCE SECOND SIDE MAY BE ENERGIZED IN THE OPEN ELECTRICAL SHOCK HAZARD SOURCE IS PHOTOVOLTIC SYSTEM POSITION THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED 2020 NFPA 70,NEC 690.53 AND MAY BE ENERGIZED NEC 705.12(C)and 690.59 I DIRECT-CURRENT PHOTOVOLTAIC POWER SOURCE PLACE LABEL ON ALL EQUIPMENT CONTAINING 1 OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER IFC 605.11.1.4 MAXIMUM VOLTAGE I 240V TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR SOURCES DC CONDUIT,RACEWAYS,ENCI OSURES,AND CABLE MAXIMUM CIRCUIT CURRENT I 16.63A I ASSEMBLIES AT LEAST EVERY 10 FT,AT TURNS AND CAUTION ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUCTION BOXES MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER CONTAINS MULTIPLE POWER OR DC-TO-DC CONVERTER SOURCES CAUTION (IF INSTALLED) I I SOLAR CIRCUIT J NEC690.13.G.3&NEC 690.13.G.4 2020 NFPA 70,NEC 690.54 INVERTER,JUNCTION BOXES(ROOF) NEC690.15,690.13(B) INTERACTIVE SYSTEM POINT OF INTERCONNECTION WARNING POINT OF INTERCONNECTION INVERTER ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC AC DISCONNECT NO USER SERVICEABLE PARTS INSIDE CAUTION RATED AC OUTPUT CURRENT: I 13.31A I CONTACT AUTHORIZED SERVICE PROVIDER NOMINAL OPERATING AC VOLTAGE:I 240V I FOR ASSISTANCE SOLAR ELECTRIC SYSTEM CONNECTED A OWNER D3.96 k PAGE PV6 MODULES: (11)HANWHA Q.PEAK DUO G10+360W DIANE SEIGAL SEIGAL RESIDENCE JOB NUMBER: 203153 411110141111 INVERTER: (11)ENPHASE IQ8PLUS-72-2-US[240V] 11 MACOMBER DR 3.96 kW DC ROOF SOLAR SYSTEM DESIGNED RV RACKING: UNIRAC NXT UTILITY: EVERSOURCE YARMOUTH PORT,MA 02675,USA SKYLINE®SOLAR REV: r DATE: Ol/20/2022 PAGE NAME. LABEL SETS FLASHING: UNIRAC NXT UmnRACCT.:— (508)776-7383 AC SYSTEM SIZE:3.19 kWAC l CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOLAR ARRAY(S) WITH SAFETY DISCONNECTS AS SHOWN: UTILITY METER—\4,0 1:01c07 /O DRIVEWAY O *_.... 45.71(9 (E)LOAD CENTER = /�� (E)NON FUSED AC DISCONNECT ~4 LOAD CENTER NON FUSED AC DISCONNECT (E)MA SMART METER . O s o V*/ MAIN SERVICE PANEL !\^,' ,/�r'' SOLAR ARRAY ON A�,, ROOFTOP 396 k . MODULES: (11)HANWHA Q.PEAK DUO-G10+360W DIANE SEIGAL L RESIDENCE JOB NUMBER: 203153 INVERTER: (11)ENPHASE IQ8PLUS-72-2-US[240V] 11 MACOMBER DR .96 kW DC ROOF SOLAR SYSTEM DESIGNED BY RV RACKING: UNIRAC NXT OWNER' itipliallgi UTILITY: EVERSOURCE YARMOUTH PORT,MA 02675,USA SEIGAL SKYLINE ,1 SOLAR REV: DATE: PAGE PV7 FLASHING: UNIRAC NXT umm ACCT.:- (508)776-7383 AC SYSTEM SIZE:3.19 kWAC C 07R0/2022 PAGE NAME DIRECTORY PLACARD p°....o or MECHANICAL SPECIFICATION Q.ANTUM �© ce Q _... -....... ...___ _.......-. %ran-1046 >lSrninl tl yM1emel Z 39e3 r �,.:: .1. ,f,termally Weatressee -.,r, letiecupn 1.5noOgy e.+-r.es. (_- 1 J ,. Composite hen „,_. I WDams Bleck enocilsed elumlMum _...... 6 x 20morocry6a9ne O.0.221 UM ss,er hall cues 0 I`,..ms. 83-101 mm x 32 60mm x 15-I I mix; • P .lion class 1P67,with bypass clostox i4.-1:2 .a.e.. • 4 mrsxSala cable.(•/31150 ,x1150mm _ � ... Sa bli MCA IP68 7 °r'2e • . I...I Q.PEAK DUO BLK-Gl + dbelay EIECTRICALCHARACTERIB'TICS _ Controlled PY POWER CLASS 7R0 RN N0 MI 370 350-370 hr r;J 4 P -O R MA!ODE AT STANDARD TEST CONDITIONS BTC-(POWER TOLERANCE•5Wr-OM .TIIVRheinlsrW Pd rat MI, p� IWI 350 365 380 3e5 370 'Dt iiTIFIfO i, rE=6 E whorl Cncelt Conant` Ix AlI 10.97 1100 U.04 1107 1110 ENDURING HIGH PERFORMANCE 25F Open Decor, o•Vew, V (VI 4111 4214 4118 41 21 4224 r M ,PP !Ai 1037 3043 1049 1066 3082 ® r�MEAAreDlY, 0I4 al MPP Vw. 'VI 33713_ 3403- 3431 3458- 3484 sa Hf Y n 1%d 195 19.8 XIS 203 206 MiNIMUF•PERf RMANC E A r NORMA,OFR OPERATING S.WWII 1fe'� + P et MPP Pies WI 2628 266.3 270,1 273.8 277.8 2021,' E Shorl Cebutt Cannot Iv Al( 8.84 8.87 8.80 892 am ELLS Warranty E Open Cnaut voltage Vo. M 38.77 38.80 38.83 38.86 3890 2 Currant et MPP It, IAI 834 8.70 8.26 831 837 V011age et MOP Awn IVI 32.24 32.48 32.71 3294 33.17 'Weeaemeet Variances Pee I3%',IY:9u,1514415TC.1000 W/M,28x2•D.AM 16 according 0 PC60904-3•'800 W,m>.NMOT.Specbran AM 1.5 BREAKING THE 20%EFFICIENCY BARRIER *MIA WARRANTY PERFORMANCE AT LOW IRRADIANCE a,. Q.ANTUM DUO Z Technology with zero gap cell layout e• Boosts module efficiency up to 209%. wa - - --"""--- slim year inamerlar Mir a� ... aeeedanpn G.vaatawa g3 sw '. THE MOST THOROUGH TESTING PROGRAMMEfN THE INDUSTRY ':I tea. powe�auNmt El1111 0 CELLS a the first Sdar modue manufacturer to pass the most comprehen- p -.....-. 15:'17;'''''"" Q 900 goCEy progronnne in itn nokWtry:The new•Cueli1y COn60Yed PV-of the 2• lum- en vM ' WI wane wsn e.craenca - EdeperxlFlnt,;ertificatiutt institute TUV RheirYantl. � -����-����� �_-���� ., ssala,'rYen,etnno vwrr - r w,.rvc......,... INNOVATlVEALL•WEATHERwTECHNOLOGY ;-�;��,�;^-„;•�„y-�- ,•• Typlcx module performance anex aw eree.nca wau�oneln Optimal yields,whatever the weather with excellent mtriprle0m05tr.cwme.nl25•C.1000W/m>l. bW-light end temperature our TEMPFRAlU1RCOUICNNfi la mnparetvr4 CoeHlwant of l,.. a p^/Kj +0.04 I mpa:e:,no COetliwunt of V.; / I%/KI -0.27 .P4_ ENDURING HIGH PERFORMANCE ramporrcracaen�w>,nl of o,,,� v 1%/q -034 No�n;nal MoaWe010121 nv temper,>m>n NMOT I•q _ 43.3 0 Long-tens yield security with Anti LID Technology.Anti PID Technology`,Hot-Spot Protect end Traceable Quality Tre.OTM. PROPERTIES FOR SYSTEM DESIGN rnenmum System valequ v,_, M 1000 Olae911 6 /�y7 EXTREME WEATHER RATING me R Current v 0) - 20 ..a ANSI!, 073g C/r7p82 s (127jJj High-tech aluminium alloy frame,certified for V high snow(5400 Pa)and wind bads(4000Pa). Ma o-'9 1 d neh/Pm hI 3eoo/28a0 - mpa.amra -bD•c-.ea•c Max-Tssr Loed,Pueh/PWI (Pe) woo/buds an Genvnuaue Duty 0 p�2..g,�a ARELIABLE 5-yesr 9TRRENT GUAURCATIO SANDCERTIRCATES----� o ,.7 Inclusive 25-year product warranty and 25-year linear performance warranty'. C °a •SOO lest snow coeditor.accord,toreinolo l0C/T382B041:2U15.IraNW A(-1500V 9651 mx Ur,09500l50r18 w.dt6 `E 0 g. •SW Jaa snow rn rw to/turswr yawmatxn Nelecrettestonnsauctona must oefdmw,n See It.instoleton and°paetng Dorval or contact our seen i taw.rbpartment Mt Dither ink>tnatnn an approved inetaretnn and I use of ties proeucl. THE IDEAL SOLUTION FOR: :7=1 itui y- mow.O0 CILIA RAH11 g /.♦ 1�i :% I U] 06766 rorteie-WdNn.Germany l TEL•4R(0)3494 NB 99.73444IF,.49(0)34946B 99.230001 ENA8eaes@r,cak corn l WEE 4wl�w(soott corn Engineered in Germany CE LLS fie u S Engineered in Germany I CELLS ENPHASE CI=1 I08 and IQ8+ Microinverters INPut DATA MCI 10t-4i-2-Us Itait us i7-2-Us Commonly used nodule pairings' w 235-350 235-440 Module compatibility 80-cell/120 half-cell 60-ca11/120 het-cell and 72-ro11/144 hall-cell MPPT voltage range v 27-37 29-45 l sw I..In: Operating range v 25-48 25-58 Min/max scan voltage V 30/48 30/58 -- Mu iiput DCwfiage v 50 60 Max DC current'!module bc) A 15 ` / Je• • Overwltage class DC port A DC port beckfeedcurrent aA 0 ii roe PV array configuration lid Ungrounded array:No addhonal DC side protection reguired:AC aide protection requires mu 20A per branch circuit OUTPUT DATA IACI rn iSI Peak output newer ;A 245 300 IR Max continuous output power VA 240 290 Nomiral(LL)vonage/isnges v 240/211-264 Max continuous output current A 10 1.21 Nominal frequency 9r 60 IQ8 and IQ8+ Microinverters Extended frequency range err 50-68 Max units per 20 A(L-LI branch circuM 16 13 Our newest IQ8 Microinverters are the industry's first microgrid-forming.software- Total harmonic distortion •5% defined microinvertars with split-phase power conversion capability to convert DC Overwltage class AC port III power to AC power efficiently.The brain of the semiconductor-based microinverter Easy to Install is our proprietary application-specific integrated circuit(ASIC)which enables the •Lightweight and compact with AC port back-feed current aid 30 microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors Power factor setting to 55nm technology with high speed digital logic and has super-fast response times •Power Line Communication Grid-tred power factor(adjustable) 0.85leading-0.95 lagging to changing loads and grid events.alleviating constraints on battery sizing for home (PLC)between components Peat efficiency x 97.5 97.6 energy systems. •Faster installation with simple CPC weighted efficiency a 97 97 two-Wire Cabling Night-time power consumption oW 60 Enphase etc/AUICAI DATA "- High productivity and reliability Ambient temperature range -40°C to•60°C(-40°F to v140°F) •Produce power even when the Relative humidity range 4%to100%(condensing/ • grid is down - DC Connector type MC4 •More than one million cumulative Dimensions(HuWsDI 212 min 18.31x 175 min(8.91x 30.2 min(1.21 Part or the Enphase Energy System,108 Seas IOU Series Mcroinveters redefine reliability hours of testing Mimi nvertersIntegrate with the Enphase to standards with more than one minion Weight 108 kg(2.381bs) Battery.Enphase 10 Gateway.and the Enphase cumulative hours of power-an resting. •Class ll double-insulated cool Natunlconvecbon-nohrns App monitoringIgnited and analysis software enabling an industry-leading ted warranty enclosure W up to 25 years. •Optimized for the latest high- Approved mil wet locations Yes'1 powered PV modules Acoustic noise at ton <60dBA Cu L Pollution degree PD3 C Microgrid-forming Enclosure l double-insulated.corrosion resistant voNmark enclosure) C.I IT TII II L) •Complies with the latest Ewe..category/UV exposure rating TEMA Type6/outdoor advanced grid support Connect PV modules quickly and easily to 108 Series Microlnvertera are UL Lusted as •Remote automatic updates for CA Rub 21(UL 1741-yU.UL 62109-1,UL7741/IEEE1547,FCC pan 15 Class B.ICES-0003 Clam&CAN/CSA-C22.2 NO.107.1-01 108 Series Microinverters using the Included PV Rapid Shut Down Equipment and conform the latest grid requirements O-DCC-2 adapter cab.with pug-n-play 1.1C4 with verb.regulations.when installed Certifications This product is UL Listed as PV Rapid Sian Down Equipment and conforms with NEC 20W.NEC 2077.and NEC 2020 section connectors. according to manufacturers instructions. •Configurable to support a wide 60.12 and C22.1-2018 Rub 64-218 Repd Shutdxwnot PV Systems.for AC and DC conductors when installed accordngto range of grid profiles manufacturer's instructions. C 2021 Enphase Energy.NI fights reserved.Enphase the Enphase logo 10emicrclnverters. •Meets CA Rule 21(UL 1741-SA) (1)No enforced DC/AC ratio.See the compatibility calculator et hnpsJ/tnk.enphase.cnm/ and other names are trademarks of Enphase Energy.Inc.Data sublect to charge requirements medub<cmpatiblity(2)Maximum continuous input DC current A 10.6A(3)Nominal voltage range can be extended beyond nominal If required by the utility.(4)Limits may vary.Refer to IO8SP-DS-0002-01-EN-US-2021-10-19 focal requirements to define the number of mcroknverters pet branch In you area 1085P-DS-0002-01-EN-US-2021.10-19 Enphase IQ Combiner 4/4C Data Sheet MODEL NUMBER Enphase Networking IQ Combiner 4(X-IQ-AMI240-I) IQ Combiner 4 with Enphase IC)Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20+/-0.5%)and consumption monitoring(+/-2.5%).Includes a silver solar shield to match the IQ Battery system and IQ System Controller 2 and to deflect heat IQ Combiner 4C(X-IQ-AM1-240.4C) IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 of.0.5%)and consumption monitoring(+/-2.5%).Includes Enphase Mobile Connect cellular modem ............._............_._-._..._._____...__......._____.__....—__.........._.__..._.___..._.._..,----......_.................___....._.....__..____....__.._....____..........._.__......._____..._._..._._........._._................................___. (CELLMODEM.M1.06-SP-05),a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands,where there is adequate cellular service in Enphase The Enphase IQ Combiner 4/4C with Enphase the installation area(Includes a silver solar shield to match the IQ Battery and lQ System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (notincluded order separately) IQ Gateway and integrated LTE-M1 cell Q Combiner 4/4C only COMMSl Communications Kit -Includes COMMS-KIT-01 and CELLMODEMM106-SP05 with 5-year Sprint data plan for modem(included with IQ Combiner 4C) COMMS CCommunEM M1 06 Ensemble sites CELLMODEM M1-06-SP-05 -4G based LTE-M1 cellular modem with 5-year Sprint data plan X-IQ-AM1-240-4 consolidates interconnection equipment CELLMODEM-M1-06-AT-05 -4G based I.TE-Mr cellular modem with 5-year AT&T data plan Circuit Breakers Supports Eaton 8R210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. X-IQ-AM1-240-4C into a single enclosure and streamlines IQ BRKrea-240V Circuit breaker,2 pole,1OA,Eaton BR210 BRK-15A-2-240V Circuit breaker,2 pole,15A,Eaton BR215 microinverters and storage installations by BRK-20A-2P240V Circuit breaker,2 pole,20A,Eaton BR220 BRK-15A-2P-240V'13 Circuit breaker,2 pole,15A,Eaton BR215B with hold down kit support providing a consistent,pre-wired solution for BRK.20A-2P-240V-8 Circuit breaker,2 pole,20A,Eaton BR220B with hold down kit support EPLC-Dl Power line carrier(communication bridge pair),quantity-one pair residential applications.It offers up to four c '- XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C 2 pole input circuits and Eaton BR series XA-PLUG-120-3 Accessory receptacle for Power Line Carrier I SC rob 4/4C)req selfor EPLC-01) ' busbar assembly. XA-ENV-PCBA-3 Replacement IQ Gateway punted circuit board(PCB)for Combiner 4/4C 0 a�., X-I0-NbHD-125A Hold down kit for Eaton circuit breaker with screws. Sr , ELECTRICAL SPECIFICATIONS Smart Rating Continuous duty •Includes IQ Gateway for communication and control System voltage 120/240 VAC,60 Ne •Includes Enphase Mobile Connect cellular modem Eaton BR series busbar rating 125 A (CELLMOOEM-M1-06-SP-05),included only with IQ Max.continuous current rating 65 A , Combiner 4C Max.continuous current rating(rput from PV/storage) 64 A , •Includes solar shield to match Enphase IQ Battery Max.fuse/circuit rating(output) 90 A aesthetics and deflect heat Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DO)breakers only(not included) •Flexible networking supports Wi-FI, Max.total branch circuit breaker rating(input) BOA of distributed generation/95A with IQ Gateway breaker included Ethernet,or cellular Production metering CT 200 A solid core pre-installed and wired to IQ Gateway I •Optional AC receptacle available for PLC bridge itilli 'Provides production metering and consumption Consumption monitoring CT(CT-200-SPLIT) A pair of 200 A split core current transformers t: - monitoring MECHANICAL DATA,., Dime.._ ..... ..... ....._.....__.___37.5_._950�._.. '' 'a6,63t___..0.. _. 1 ,•W Dimensions(WaHVD) 37.5x49.5x16.8cm(14.75'K79.5'x6.63').Height Is 21.06'(53.5 cm)wimmounting brackets. *IA• Simple Weight 7.5 kg(16-5 ins) Ambient temperature range -40°C to+46°C(-40°to 115°F) i •Centered mounting brackets support single Cooling Natural convection,plus heat shield { ~• stud mounting Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction •Supports bottom,back and side conduit entry Wire sizes •20 A to 50 A breaker inputs:14 to 4 AWG copper conductors •Up to four 2-pole branch circuits for 240 VAC •60 A breaker branch input:4 to 1/0 AWG copper conductors plug-In breakers(not included) •Main lug combined output 10 to 2/0 AWG copper conductors X-1Q-AM1-240-4C •BOA total PV or storage branch circuits •Neutral and ground.14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters(6,560 feet) E1 . _. Reliable INTERNET CONNECTION OPTIONS Integrated Wi-Fe 802.ttb/g/n •Durable NRTL-certified NEMA type 3R enclosure •Five-ear limited warrantyCellular CELLMODEM M7.06SP OS,CELLMODEM-M1-06-AT-Os(4G based LTE-Ml cellular modem).Note that Enphase y Mobile Connect cellular modem is required for all Ensemble installations. •Two years labor reimbursement program coverage Ethernet Optional,802.3,Ca15E(or Cat 6)UTP Ethernet cable(not included) included for both the IQ Combiner SKU's •UL listed COMPLIANCE Compliance,ID Combiner UL 1741,CAN/ESA C22.2 No.107.1,47 CFR,Part 15,Class B,ICES 003 I Production metering:ANSI C12.20 accuracy class 0.5(PV production) Consumption metering:accuracy class 2.5 0Compliance,IQ Gateway UL 60601 1/CANCSA 22.2 No 61010-1 LISTED XdQ-AM7-240-4 To learn more about Enphase offerings,visit enphas.€•Com e E N PHASE To learn more about Enphase offerings,visit enphasesgtn e EN PHASE Cr 2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo.IS Combiner 4/4C,and ottax names are trademarks of tnphase Energy,Inc.Data subject to change.10-21-2021 A m Q I 0• a 3 • A 5 s ii .- ae g `IF '� mm i. Cj V 4 f W F 3 1 i P;' F 1 i ! » I'� Q p 4, I ,T d n + fp j y� r D 7f G In w O G13 C �. ` r j( per. �° K "T , N ¢I U1 n3 UT 7.1 y 1 .. A ' 6 .'b. :5- 5 --1 5 : 2 : 1' 3' i if ER '7' ED I") 2 g w en m � N C O r 19 i I R - of n s j 7 9 r c v R W a as � .m r . `vim C ii 3 3 m r �� a� o a r•r,ir. mLAJ g V _ 1\J 3a = ca O CD - _ in so S � =� - CD .-2 It � � O 7 I C 21L �� � M = v c o -. -< rn N ' Y- Q C d 0 O n n Q O r- c�Hig D_ o N c� TT C 2 �xo C N N C �. -� $ m CD C lon T Z I il ! Z .41 q z i s S 3 d X \/ milimemom nn fr y d? = /� .� aa ie} sog a B1? x � n = N RR a- `� = 333i, -. a s g Q -- C� O O c' l! g 3 t z N v s� gnat — m '^ co c) co 7 co) a r— Z CD CD E I' I �t c� O l C Lk MI m Con z 1,... 1 O ;ii a , w. o aR Sg°°i: n 5' i 3 I;: 1 3 C .am_ -o IH ' P11 ` ■a• Z �a z a A ■. cm -� 3. ;it a gag m O s Zfn T ! 3 9 0 X v a MMIIIMNI r _ y rri gnil 1 ''i 4111110 mg po ( sc s r=rill it- =,— t r u z 2 =3= �`21- o � �E = n :wpilia0>HORIZONSYSTEM GROUNDING ; l' , • : PAGE I• ..•4• ' ...,-- •.,e-, , --- .., 0°.° ,41. ---....- . .400- ... <,,,,, - SYSTEM GROUNDING:Rails can be bonded using an NXT Horizon MLPE&Lug SYSTEM GROUNDING WITH MLPE&LUG CLAMP:Insert the rail nut profile in Clamp,GROUND WEEBLUG#1 or ILSCO LAY IN LUG(GBL4DBT).At least one the opening by lifting the flaps of the plastic clip.Rotate the clamp 90 deg and rail per row of modules in an array must be bonded to electrical ground.Each release the flaps to get flush with rail.Ensure that the rail nut is engaged in the additional row of modules must be grounded with at least one rail lug per row rail profile.Align the ground wire in the depression of the washer.Tighten bolt. or with a row-to-row bonding devise listed here. TORQUE VALUE.6-a AWG.12 tt:u . Note:See Page F for additional lugs required for expansion Ic-;., CAUTION:MLPE&Lug Clamp cannot be used to simultaneously mount a MLPE and ground wire. el • 0 r e PL ALTERNATE SYSTEM GROUNDING WITH ILSCO LAY-IN LUG-UNIRAC P/N 008009P: ALTERNATE ROW GROUNDING WITH NXT ALTERNATE ROW GROUNDING WITH N/S Alternate Grounding Lug.Drill hole in rail 7/32"in diameter,deburr hole and bolt thru HORIZON ROW BONDING CLAMP: BONDING CLIP: one wall of rail. Insert clamp between module rows and Fully seat bonding clip on each module tighten bolt. flange to provide bond across N/S I3O0 TORQUE VALUE.-ft Un module gap. '1 RPM7Ntt TCTROO 2 s AWG SStr-t - "0 r' c -II,, TORQUE VALUE:20 ft•ibs WARNING:ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION •® � R IM>HORIZON APPENDIX j� BONDING CONNECTION GROUND PATHS I PAGE RACKING SYSTEM GROUND Groi,»a Lug we Bare BONDING Copps Wire MICROINVERTER Note.Ordy pot tug pee moaute MOUNTS now regWrerl �' BONDING RAIL SPLICE BONDING COMBO CLAMPS • ALTERNATE ♦I . . ROW-TO-ROW-► i BONDING •I METHOD i n� APPENDIX3 . aaHoRizoN SYSTEM CERTIFICA PAGE The NXT Horizon system has been certified and listed to the UL 2703 standard(Rack Mounting Systems and Clamping Devices for Flat-Plate Photovoltaic Modules and Panels).This standard included electrical grounding,electrical bonding,mechanical load and fire resistance testing. SYSTEM LEVEL FIRE CLASSIFICATION The system fire class rating requires installation in the manner specified in the NXT HORIZON Installation Guide.NXT HORIZON has been classified to the system level fire portion of UL 2703.NXT HORIZON has achieved system level performance for steep sloped roofs.System level fire performance is inherent in the NXT HORIZON design,and no additional mitigation measures are required.The fire classification rating is only valid on roof pitches greater than 2:12(slopes%2 inches per foot,or 9.5 degrees).The system is to be mounted over fire resistant roof covering rated for the application.There is no required minimum or maximum height limitation above the roof deck to maintain the system fire rating for NXT HORIZON.Approved Module Types &System Level Fire Ratings are listed below: Module Type System Level Fire Rating Rail Direction Module Orientation Type 1,2,3,10,19,22,and 25 Class A,Class B&Class C Parallel OR Perpendicular to Ridge Landscape OR Portrait MECHANICAL WAD TEST MODULES The modules selected for UL 2703 mechanical load testing were selected to represent the broadest range possible for modules on the market.The tests performed covers module frame thicknesses greater than or equal to 1.0 mm,single and double wall frame profiles(some complex frame profiles could require further analysis to determine applicability),and clear and dark anodized aluminum frames. Tested Module UL2703 Certification Load Ratings Tested Loads Tested Module Area SunPower SPR-A440-COM Down:113 psf,Up:50 psf,Slope: 'Down:170 psf,Up:75 psf,Slope:23 psf 21.86 sq ft 15 psf UL2703 CERTIFICATION MARKING LABEL: Unirac NXT HORIZON is listed to UL 2703.Certification marking is embossed on UNIRAC all Combo Clamps as shown. Labels with additional certification information are provided with clamps and must be applied to the NXT Horizon Rail at the edge of the array. ell) a 4 Note:This racking system may be used to ground and/or mount a PV module C US complying with UL1703/UL61730 only when the specific module has been 266909 evaluated for grounding and/or mounting in compliance with the included instructions, :Ileaea T APPENDIX ;EED>HoRizoN SYSTEM CERTIFICATION ; PAGE Electrical Bonding and Grounding Test Modules The list below is not exhaustive of compliant modules but shows those that have been evaluated and found to be electrically compatible with the NXT Horizon system. Manufacture Module Model;Series Manufacture Module Model/Senn Manufacture Module Model/Series Ale° P-Series&S•senes Cert0osetar America (-Series&E-Series tInxo '1KM A 11CMS Series 1 DNA 120-(MFBF)23 CT2ssMxx-01.CT2xxPxx•01.CTxxxMxx•01. Kyocera KD-F A KU Series DNA•144-(MFBF)23 CerwmTeer CTxxxP Txxx xx-01,CtIxx-02.CTuxxHxx-03 ........ ....__._.._..._____ ..�......._.._.__._......"I Antos Sol LGKKKIE1C/EIKMICMIK/N2TM2W/51C/ DNA-12041F26 CTxxxMKx-04.CTilniHC11-04 52W/Q1C/Q1K)-AS DNA-14444F26 Eco Sotargy Orion I000&Apollo 1000 LGxxx(A1C/F11C/M1K/N1C/NSK/Q1C/Q1K/ CHS146612 M,MRa ET Solar ET AC Module,ET Module QAC/QAK)-A6 (HS/46612P Series - tbxxxN2W-B3 Astronergy tlextronics i•XS-xxoBB CHSM66129/HV Series . _... LG Electronics lGasa(N2T/N2w)-E6 CHSM72M-HC. GCL GCL-P6 A GCL416 Series LGxxx(N1CM1K442W/S1CIS2w-G4 _.___...._..._.___.. LGKxxN2T--JS AXN6M610T, Hanwna SolarOne HOC 60 LGxxx(NIKIN2T/N2W)-LS Auxin AXN6P610T, TD•ANS,TD-AN4, LGxxx(MIC/NIc)-NS AXN6M612T Hansol AXNEP612T UB-ANI,UD-AN1 _.. LGxxx(N1C/N1K/N2W/Q1C/Q1K)VS ,, ,Hetiene 36M 36P 60M 60P 72M&72P Slues _ _.. 1R4.60(HPBMPH) AC-xxx0/156.60,AC-xxxBM/Py72S AC-xxxP/1S6-rS05 HT72.156(1VP). LR4-72(14PH) AZKlt AC-xupH/120(S/V158/V8) HT72-156PC,HT72.356PM< LR660 HT Sour HT72.156M(PDV)-BF.HT72-156F1(PD)-BF LR6-60(BK/HPB/HPH/HV/PB/PERN) AC-xexMM/144(5/VhB/VB) LONG' I RA.77 Bonet 13VM6610.BVM6612 HT60.15614(V)•C LE6-72(B104V/PB/PE/PH) BYD P6K A MKS S6 Series ReaLBlack LR4.60HP13 KG,MG,RW,TG,RI,RG,TI,K L HI Series CS1(WK/U)-its " Fiyunoai HID-SUXRG(BK),HIS-S40OPl Real6Utk 1R6.60HP8 CS3K-p4e/11B-AWMS/P/P HE/PB-AG) iTEK IT-SE Series Mission Solar Energy M5E Mono,MSE Pert C531-(MSIP) ttnsubisnr r•UE&MLE Series C53U•(MB/MB-AG/MS/P/P HERB/PB-AG) Japan Solar t0S-60&JP5.72 Series CSSW(MS/P/P•PB-AG) 1496 60-sos. Men solar Power Co OW Series ",..". " 1 Canadian solar CSSA-M PA46(K)-60/xxx,JAP6(k)-72-exx/4BB. VBtINESKSA06/SA066/SAII/SA11B CS6K1M/MS/MS AUBIacK/P/P HE) 1AP72SYY-xxx/ZZ- VBHNEXKSA1S/SA1S8/SA16/SA168. CS6P-01/P) JAPE(k)-60-xxx/488,1AP605YY•xxx/ZZ. VBHNZKUKA,VBHNxxOKA03/04. CS6U-(M/4s/P HE) iA Sol IAM6)k1-72•xxx/LZ,1AM72SYY-Kxx/ZZ Panasonic VBHNxxoSA17/SA17G/SA17E/SA18/SA18E, Cs6X•P IAM6(10-60-xxx/ZZ.IAM60SYY-xxx/ZZ VBHNAKKZA01/ZA02/2A03/11BHNKK0ZA04 CSX-P r YY.01,02.03.09,10 EVEN ELPS CS6(A/P-MM I.2Z SCPR,BR HIT,18,SAW Peonar sGxxxM(Fvan '{Y s Bxksneet,22 Celt tecnnotogy ' •The frame profile must not have any feature that might interfere with the bonding devices that are integrated into the racking system •Use with a maximum over current protection device OCPD of 30A •Please see the SM UL2703Construction Data Report at Unirac.com to ensure the exact solar module selected is approved for use with NXT Horizon •Listed models can be used to achieve a Class A fire system rating,for steep slope applications,only when modules fire typed 1,2,3,or 10.See Appendix page 3 7flM ' APPENDIX , iSYSTEM CERTIFICATION ; PAGE Electrical Bonding and Grounding Test Modules The list below is not exhaustive of compliant modules but shows those that have been evaluated and found to be electrically compatible with the NXT Horizon system. Manufacture Module Montt I Sales Manufacture Modute Model 7 Sella Manufacture Module Model i Series PSzxxM1-20/U S-Energy SN12 d SN60 Senes Testa SC,5C B.SC B1.SC 02 PSxxcMIH-20N SEG-(6PA/6P8/6MA/6MA-HV/6MB/E01/E11) PA05,PROS.D00I.DD06.DE06 PSxxxhil 20UH Trina PD14,PE14,DD14,DE14,DEIS PSxxx MS N-20uH 5RD•(6QA/6Q6) PSxxxM .2 UH RP Seraphim SRP-xxx-6M8-HV,SRP-320-375$MB-HV, TSMC TS-150C2 C1GSw Phono Solar S -xxx-BMC-HV,SRP-390-450-BMA-HV, PScanM1H-20NH UPso� UP-MxxzR UP•Mxxxf1(•81 RP-xxx-6MZ-NV,SRP-390-405-BMD-HV PSxxxM•24/T PSxxxMH-24/T Sharp NU-SA&NU-SC Series uRE D7f•1xxxH 8A,D7KxxxHBA, 07MxxxH7A,D7KxxxH7A PSxxxM-24/TH SLAM.SLAP,SIG-M.SLG-P&BC Series -- -- -- , Sittah V,kram E laora,Somera,Utnma PSxxxMH-24,1TH SILAxx(BORINTMVMI./BK/NX/NU/HC) , VSUNxxx-60M-BB.VSUNxzx-72MH PUN,Pro,Peak,G3.G4. PowerXT-xxzR-(AC/PD/BD) vSU N 5 G V5UN4xx-1MBtiH Peak GS Q.Cells (n. 6(+RSG(ACL G7,G8(�), Solana DPvarXT-zxzC-DD Plus.Pro,Peak L-G2,1-G4,L-GS VNS-72F11-S-xxxW-1 S. PowerXT-xxxR-PM(AO Peak L-GS,L-66,L-G7.L-G818FF),ML-G9(s) . - VN5-72113-S-xxxW-1 S. SOWrtech STU HIT.STU PERC&Quantum PERC RECxxxTP72.RECxxxTD - _.. __ __. _.... Vona VN5144MI S arzW1 5, RECxxxPE 72.RECxuPE `SotarWor IP Sunmodute Protect,Sunmodule Plus/Pro VN5-1+4r•13-5-xxxw-15. REC RECxxxTP25(M)72.RECAxzTP28LK2. Sumecn STP VNS-1201.13-5-xxaW-1.0 RECxxxTP1(Try WST&WSP Series ,unrra MV Series&OPumus Sales i35mm) Wtnaico RECxxkNP(N-PEAK) - vingu YGE&TM Saxes RECxxxAA(BLK) Sun Eason F-Series.R-Series Renesola AU 60-cell modules SunPower AC,h-Series,E-Series&P-Series Risen RIM Series TP572,TP596,TP654,TP660. ___._ ..._.._... _ Tatesun TP672,Hlpor M,Smart •The frame profile must not have any feature that might interfere with the bonding devices that are integrated into the racking system •Use with a maximum over current protection device OCPD of 30A •Please see the SM UL2703Construction Data Report at Unirac.com to ensure the exact solar module selected is approved for use with NXT Horizon •Listed models can be used to achieve a Class A fire system rating,for steep slope applications,only when modules fire typed 1,2,3,or 10.See Appendix page 3 aa 0 Ground Snow O O O O Load(vs% p :: : : : : : ; : : ; : : ; 9 ▪ � a r idegl t, i, • > e»>Eaaeee>_e ? ??.. >atFM i._ irnt.Trrnti,e ero.wr. N '*, ` ' Pe,...�.woig.•ogmmgmP,gmPgOti m-mm. m g. �§,79' ..,...,:8, O E '. . Q \ p n` v..'. tiOwvasz4 z. P.nm m m Ob O w ..�v O. n £s N s a ,iN ?.'No��o o 4 aomP m a sN "s 44 CD io Aw>tia1Nzo,tmmlgm mP.m m m . H, :- .�. Z 7 (( * . ♦ , a n i vim J v a Z g r+O�•n m.w,em Qom P.'O.•. m m ..� _ �1 g O x i PIa � .-> .".o'.m,••".•omimmmmaiomP•-m mm��.mm r•- -• '.o:'-n,,,,. •„tiw,,,ti G a� 8�m mP m m • oo 3 E .�w�o1 wa�mm1�maio mmN ag o n a ,,I _. owtiolNwom%,-- mP. �o 1v g�o:s osmg 1� . 0 ti85mm m mPom m mm2. , wti g. a 2v �mP�m Pw � N — $ g , m+:w m m • � wx i _ e . s --I't— ag..,, gptiowmmNmo8mggm m, g sgvg2E.2^ om,.wo w m w °V!.m tm . o 3 X A P Plw mP.P IOVmmVP o Ctt c.5 - O iT a f i I 0 kw E_ $g V zaj>•..o.•mmwm mP Pm m• mmv«...... - o „ ,,,,,2 8 N 3 • _. _____ � mn.oip w.o ,...m.m PmmN Pl.o� mN Plg� $"� N N r - 3 e j 8 g � 2� V Im • I„ imM N.s * 3 :. - 5. — e � PN wow m mPwu m m tiw �m♦w mam1m� $ R_ E .Ia aimwa� m Vale, 1 o m 11r, $ N xa'o�aNmmm�a�mPmN �mmmP N v o 31 a !m. m O.O mP�m m r w w, s xaio�a�P��m tiw _ P � M 1 d$p .-:o n..•000 Nmvmg.P-'..�O,o.�ie O 0 T m 'e o ,,=ISl:1uo.�.•vyma.n m n.r .1 o' . i .. ., : . . € xr rovrirao n.. :: mmv.. g m , 3:a .z.1. a .. e ae i k aa .,m oa.-o m..N 1 41" w mmm.• 1 8'1—r .2.oPwo x a ` -- i v 1mNwaw�m_j_Nw,�wcm_lwmw.wEm_1w wtim ', _ . w 1 f, — 2 , naP I.PnPO,v OO p.POrl�wVi PIPP aA�D Nd NaIC OVi OeAA,�Iu mm�bPa a O cma•- P � I I, IwPP PPPv .. Wi P..m',�"r..am o > V) $'a.. w$na.,a Pgt.W.i°'$,'"o�w9go, v;$a ego ni N$o a.Pi�o� ,.o a c L 111w11emas11i1wm"11N11""1.11PmAii11Pm wEA mal,,0,14 ,�mnowP.,a w ti ..m. r_, ..m 42_ 4,e,'w..w...,V=, w •, ,nw _. ti � J”. o 11111"A1i1aA1itA1itA1°11A� N IH 0 R I Z 0 N. ASCE 7-10 ll 30 h Ss•3.00 60 Cell Portrait Cross-510pe MR Stronghold SPAN TABLES Onion Standard Reh Category Rod:RRht Sowmic haunala To, 0.4ntnm Rail Fraction Ral Typc l.nan.a-i Maximum Allowable Rail Spans for Rooftop Solar Panels Parallel to the Roof Surface(inches) e Bask Wind Speed(mph) , 8 I S 4- lC 90 95 100 105 110 115 120 130 140 150 160 170 180 1 5 g 3 Roof Wind Zone rf .. S 1 2 3 1 2 3:.: 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3: 1 2 4 1 1 3 1 2 3. 0-7 All 85 85 80 85 85 76 85 85 73 85 82 70 85 79 68 85 76 65 85 74 63 84 69 59 80 65 55 76 62 50 72 59 46 69 55 41 66 52 36 B 7.27 All 85 85 78 85 85 75 85 85 72 85 83 70 85 80 67 85 77 65 85 74 63 85 70 60 83 66 55 79 63 51 75 60 48 72 57 44 69 53 39 27-45 All 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 83 83 83 80 80 80 75 75 75 70 70 70 66 66 66 62 62 62 59 59 59 56 56 56 0.7 All 85 81 69 85 78 67 85 75 64 85 72 61 84 69 59-- -81 67 56 79 65 54 74 61 49 70 57 43 67 53 -""37 64 49"_ 61 46 _ 59......._41....alle 0 C 7.20 All 85 82 69 85 78 66 85 75 64 85 72 62 85 70 59 84 68 57 82 66 55 77 62 50 73 58 46 69 54 40 66 50 35 63 47 _ 61 43 0.1111 20.27 All 86 86 86 85 85 85 81 81 81 78 78 78 75 75 75 72 72 72 69 69 69 65 65 65 60 60 60 57 57 57 53 53 53 50 50 50 48 48 48 0.7 All 85 76 65 85 73 62 85 70 -._60 82 67 57 79 65"'-54 76 63 51 74 61 48 70 56 42 86 52 36 63 48 MI 60 44 _ 57 38 _ 54 34 MEI 0 7.20 All 85 76 65 85 73 62 85 71 60 85 68 58 82 66 55 79 64 52 77 62 50 72 58 46 69 53 39 65 49 34 62 46 MN 60 41 NM 57 36 MIN 20.27 All 83 83 83 79 79 79 76 76 76 7; 73 73 70 70 70 67 67 67 64 64 64 60 60 60 56 56 56 52 52 52 49 49 49 46 46 46 44 44 44 �_T-- 0-7 All 72 72 72 72 72 71 72 72 72 71 72 70 72 72 68 72 72 65 71 72 63 72 69 59 71 65 55 72 62 50 72 59 46 69 55 41 66 52 36 B 7-27 All 72 72 72 71 72 72 72 72 72 72 72 70 72 72 67 72 72 65 72 72 63 72 70 60 71 66 55 72 63 51 70 60 48 68 57 44 66 53 39 27.45 All 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 83 83 83 80 80 80 75 75 75 70 70 70 66 66 66 62 62 62 _59 59 59 56 56 56 0.7 All ---"72 72 69 72 72 67 72 72 64 72 71 61 72 69 59 72 67 56 72 65 54 72 61 49 70 57 43 67 53 37 64 49 _ 61 46 ..1-59 41 NMI 10 C 7-20 All 72 72 69 72 72 66 72 72 64 72 72 62 72 70 59 71 68 57 72 66 55 72 62. 50 69 58 46 67 54 40 65 50 35 62 47 moi 60 43 MIN 20-27 All 85 85 85 84 84 84 81 61 81 78 78 78 75 75 75 72 72 72 69 69 69 65 65 65 60 60 60 57 57 57 53 53 53 50 50 50 48 _48 48 0-7 All 72 72 65 72 72 62 72 70 60 72 67 57 72 65 54 72 63 51 72 61 48 70 56 42 66 51 36 63 48 _ 60 44 _ 57 33 _ 54 34 _ D 7-20 ALL 72 72 65 72 72 62 71 71 60 72 68 58 71 66 55 71 64 52 71 61 50 69 58 46 66 53 39 64 49 34 61 46 MO 59 41 NM 57 36 MEN 20.27 All 83 83 83 79 79 79 76 76 76 73 73 73 70 70 70 67 67 67 64 64 64 60 60 60 56 56 56 52 52 52 49 49 49 46 46 46 44 44 44 0-7 All 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 59 60 60 55 60 60 50 60 59 46 40 55 41 60 52 36 B 7-27 All 60 60 60. 60 60 60 60 60 - 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 55 60 60 51 59 59 48 58 57 44 57 53 39 27.45 All 77 77 77 77 77 77 77 77 77 77 77 77 77 77 77 7575 75 74 74 74 70 70 70 67 67 67 65 65 65 62 62 59 59 56 56 56 0-7 AIL 60 60 60 60 60 60 60 60 60 60 60 60 60 60 59 60 60 56 60 60 54 60 60 49! 60 57 13 60 53 37 60 49 62 59 46 59 58_ 41 20 C 7-20 All 60 60 60 60 60 60 60 60 60 60 60 60 60 60 59 60 60 57 60 60 55 60 60 50 58 58 46 57 54 40 55 50 35 54 47 ME 53 43 MEI 20-27 All 77 77 77 76 76 76 74 74 74 72 72 72 70 70 70 69 69 69 67 67 67 64 64 64 60 60 60 57 57 57 53 53 53 50 50 50 48 48 48 __. __.. __...___ 0-7 All 60 60 60 60 60 60 60 60054 60 60 60 57 60 60 54 60 60 51 60 60 48 60 56 42 60 52 36 60 48 MI 59 44 1.1.1 57 38 Mil 54 34 _ D 7-20 All 60 60 60 60 60 60 60 60 60 60 60 58 60 60 SS 60 60 52 60 60 50 58 58 46 56 53 39 55 49 34 53 46 1111111 52 41 Mall 50 36 EMI 20.27 All 76 76 76 74 74 74 72 72 72 70 70 70 68 68 68 66 66 66 64 64 64 60 60 60 56 56 56 52 52 52 49 49 49 46 46 46 44 44 44 0.7 All 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 55 59 59 50 59 59 46 59 55 41 59 52 36 B 7-27 All 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 55 60 60 51 59 59 48 58 57 44 57 53 39 27.45 All 71 71 71 71 71 71 71 71 71 71 71 71 71 71 71 69 69 69 68 68 68 66 66 66 63. 63 63 61 61 61 58 58 58 56 56 56 _ 54 54 54 0-7 AIL 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 56 59 59 54 59 59 49 59 57 43 59 53 37 59 49 58 46 57 41 C 7. 60 60 59 60 60' S7 55 60 I 6050S8581655440555035547 5343i 20_2720 AlAllI 60 71 71607160 7060 60 70 60_70 60 fi8 6R60 6660 0760 6760 6760 65 65 65 64 64 64 60 63 6360 63_ 60 60 60 57 57 57 55 55 55 52 51 52 50 50 50 48 48 48 0-7 All 60 60 60 60 60 60 60 60 60 60 60 57 60 60 54 60 60 51 60 60 48 60 56 42 60 52 36 60 48 III. 59 44 NM 57 38 11101 54 34 MN D 7.20 All 60 60 60 60 60 60 60 60 60 60 60 58 60 60 55 60 60 52 60 60 50 58 58 46 56 53 39 55 49 34 53 46 111111 52 41 0.0 50 36 _ 20.27 All 71 71 71 69 69 69 67 67 67 66 66 66 64 64 64 62 62 61 61 61 61 58 58 58 55 55 55 52 52 52 49 49 49 46 46 46 44 44 44 0.7 All 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 50 54 54 46 54 54 41 54 52 36 8 7.27 ALL 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 51 54 54 48 53 53 44 52 52 39 27-45 All 66 66 66 66 664 66 566 6654 66 664 5664 5(i64 66 66 65 65 65 64 64 64 62 62 62 59 59 59 58 58 58 56 56 56 54 54 54 52 52 52 ac 40 _... C 70 All 55 55 55 55_., 55 55 55_.. 55 55 55 55 55 55__..55._w 55_..Y55 54 64 54 54- 54W 54._. 19... 54...—54_.._43 54_.._S3... ;7"S4 45,__53 ati _,51.... 41 i' 55 55 55 55 55 55 55 50 54 54 46 53 53 40 51 50 3S 50 47 NM 49 43 _ 20-27 ALl 66 66 66 6S 65 65 64 64 64 63 63 63 61 61 61 60 60 60 59 59 59_ 57 57_ 57 _55 55 SS 52 52 52 50 50 50 48 d8_ 48 47 47 47 D 7-20 AU 57 57 57 57 57 57 57 57 57 57 57 57 57 57 55 57 57 52 57 57 50 55 55 46 54 53 39 53 49 34 51 46 50 41 49 36 0-7 Au 56 56 56 56 56 56 56 56 56 S6 S6 56 56 56 51 56 56 51 56 56 48 56 56 41 56 52 36 56 485 8 55 445 4110. 54 3 41 MI 49 36 11111. 20-27 All 66 66 66 65 65 65 63 61 63 62 62 62 60 60 60 59 59 59 58 58 58 55 55 55 53 53 53 50 50 50 48 48 48 46 46 46 44 44 44 • Cells with an asttsks Indicates that the 1-foot must be oriented In the Y-direction as Indicated In the Image below.Applicable only for very high snow loads. mop Cells with an'%'Indicates that the Combo Clamp allowable capacity Is exceeded and a 3-rail system may be required.Contact 0nirac Engineering Services for suppon. 'Stronghold Attachment Kit GABLE ROOF(T-ri GAME HOOF 1T-0-, MP HOOF 0MillY* 4 I toi t47 Km �tst -L - . WIWIa uo�o n...� art 4 [w� Kgsr aTWig 41 tUaDaro Cr ar T SC F Y_ a+AaN ae ls xT,auyp tp80ant/ a•NAxld Ode lR.MW010a,04n11 "Wind loads used to generate the span tables for modules with maximum dimensions of 671n x 40.11n(60 Celli and 801n x 41in(72 Cell)are based an ASCE 7-10,Section 30.4.2