Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
31 Bliscott Ave plan 7
(2)1-:Y4"x 16" —. LVL RIDGE 2x10 RAFTERS @- 16" O.C. (TYPJ Y4" T&G PLYWOOD - SUB -FLOOR GLUED AND NAILED (TYP.) 2x1D ATTIC —� FLOOR JOISTS @ 16" O.C. (TYP.) (3)1-Y4"x 11-Ys'_-J LVL WATERPROOF ROOF DECK: 2x10 P.T. @ 16" O.C. _ TAPERED AT %" PER FOOT W/ 2x P.T. SLEEPERS ABOVE 12- 4r% (3) 242 P.T. HEADER 6"x6" P.T. POST CONT. FROM HEADER TO SONOTUBE (TYP.) @ DECK COLUMNS I � II 10" DIA. SONOTUBE W/ I i BIGFOOT FOOTING (BF28) FOR COLUMN SUPPORTABOVE I CONNECTIONS PER AISC FLOOR JOIST, SIZES VARY 2x8 BOLTED TO BEAM SIZES VARY ENCASE STEEL BEAM IN FIRE RATED SHEETROCK 2x8 BOLTED TO — FLANGE GARAGE: JOIST TO STL. BM. CONNE SCALE: NOT TO SCALE CTION HEAD OFF RAFTER OP'G FOR HVAC CENTER UNDER CONT. RIDGE VENT / (TYP-) zx12 RIDGE (2)1-�Y4'x 16" LVL RIDGE 2x8 NAILERS TYP. @ LAY ON ROOFS 12 SECTION SCALE: %4" = 1'-0" 2x10 RAFTERS Co) 16" O.C. (TYP.) 2x8 CATHEDRAL CLG. BOTT. CATHEDRAL JOISTS @ 16" O.C. CLG. JOISTS TOP OF PLATE _GARAGE: T.O. P. MAIN 2ND FL PROPOSED EXTERIOR WALLS (TYP.) • WHITE CEDAR SHINGLES @ 5" EXPOSURE o • TYVEK HOUSEWRAP • %" CDX SHEATHING • R-20 BATT INSULATION • 2x6 @ 16" O.C. • VAPOR BARRIER •° GWB 1ST FL SUBFL: elevation 14.5' m FEMA AE FLOOD ELEVATION 11.0' fV 2)1-%4'x 16" LVL RIDGE 12 2x10 RAFTERS @ 6.5 16" O.C. (TYP.) _.00 A SECTION SCALE: %4" = 1'-0" ( 2x10 P.T. PORCH ROOF RAFTERS @ —16" O.C. — (3) 2x12 P.T. HEADER F1x8 FASCIA, lx8 SOFFIT 6"x6" P.T. POST CONT. FROM HEADER TO SONOTUBE (TYP.) @ DECK COLUMNS 2x10 P.T. DECK JOISTS @ 12, O.C. (TYP.) FRAMED LATTICE BELOW DECKS (TYP.) I I I I I I I I I 1 I I I Issued for Construction: 10/29/21 1. ALL EXTERIOR WALLS SHALL BE 2X6 @ 16" O.C. UNLESS OTHERWISE NOTED. 2. ALL INTERIOR WALLS SHALL BE 2X4 @ 16" O.C. UNLESS OTHERWISE NOTED. 3. CONTRACTOR SHALL VERIFY ALL WINDOW ROUGH OPENINGS PRIOR TO ORDERING WINDOWS. 4. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. CONTRACTOR ASSUMES RESPONSIBILITY FOR ANY MISSING OR INCORRECT DIMENSIONS NOT BROUGHT TO THE ATTENTION OF THE DESIGNER. REVISIONS NO. REVISION DATE © COPYRIGHT NORTHSIDE HEREBY EXPRESSLY RSERVES ITS COMMON LAW COPYRIGHT. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF NORTHSIDE DESIGN ASSOCIATES GENERAL NOTES .i 14 V i%. i A A " A Aj DESIGN ASSOCIATI VCTIVE RESIDENTIAL & COMMERCIAL D'. MAIN STREET * YARMOUTHPORT * MA ( ;08)362-2210 (508)362-98( NORTHSIDEDFSIGN_COM PROJECT #: SHEET 20-31 A.5 DATE: OF 10/29/21 14