BLDE-23-001057
Commonwealth of Official Use Only � , '�`J' 1Permit Massachusetts No. BLDE-23-001057 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.l/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:8/29/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 107 MERCHANT AVE Owner or Tenant JOYCE MARIA Telephone No. Owner's Address 107 MERCHANT AVE,YARMOUTH PORT, MA 02675 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead ❑ Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(12 Panels 4.8 KW)(NO ESS) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil: No.of Total Susp.(Paddle)Fans Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiatin¢Devices No.of Ranges No.of Air Cond. Ton 1 No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons 1 KW No.of Self-Contained Totals: Detection/Alertine Devices Space/Area HeatingKW Local ❑ Municipal 0 Other: No.of Dishwashers P Connection HeatingAppliances No.of Dryers PP KW Security Systems:*No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Siens No.of Devices or Euuivalent Telecommunications Wiring: No.Hydromassage Bathtubs No.of Motors Total HP No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. required bymunicipal policy.) Estimated Value of Electrical Work: (Whenq p p y' Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Matthew T Markham LIC.NO. 1136 Licensee: Matthew T Markham Signature Bus.Tel.No.: (If applicable,enter"exempt"in the license number line.) Alt.Tel.No.: Address:24 SAINT MARTIN DR,BLDG 2 UNIT 11,MARLBOROUGH MA 017523060 *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. I PER I MIT FEE: $150.00 f 3t2-v � ( (1ru Ut(i -tc u NI' 1 (/VtWL$ 23104L0 , ECEIVED r UG 2 6 2022 hh, Official Use Only o monaea o� a��ac�uae23 5'7 =_. Permit No. �-_ c7 / , C t /1KTMEN Aepartrnent o/.}ire Service3 _,__ _ ,;, Occupancy and Fee Checked �� '= l '- -  -E PREVENTION REGULATIONS [Rev. 1/07]r (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 08/24/2022 City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 107 Merchant Avenue Owner or Tenant Joyce Maria Telephone No. 508-498-8864 Owner's Address 107 Merchant Avenue,Yarmouth,MA 02675 Is this permit in conjunction with a building permit? Yes 0 No n (Check Appropriate Box) Purpose of Building residential Utility Authorization No. Amps Service 200 Am s 120 /240 Volts Overhead❑ Undgrd n No.of Meters 1 New Service 200 Amps 120 /240 Volts Overhead n Undgrd n No.of Meters 1 Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: roof mounted pv solar panels-4.800Kw system-12 total panels-200A-NO ESS Completion of the following table may be waived by the Inspector of Wires. No.of Total No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA Above In- No.of Emergency Lighting No.of Luminaires Swimming Pool grnd. ❑ grnd. ❑ _Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Detection and No.of Switches No.of Gas Burners Initiating Devices Total No.of AlertingDevices No.of Ranges No.of Air Cond. Tons Heat Pump I Number I Tons I KW No.of Self-Contained No.of Waste Disposers Totals: i Detection/Alerting Devices Municipal Other No.of Dishwashers Space/Area Heating KW Local❑ Connection ❑ HeatingAppliancesSecurity Systems:* No.of Dryers KW No.of Devices or Equivalent No.of Water No.of No.of Data Wiring: Heaters Signs KW Ballasts No.of Devices or Equivalent Telecommunications Wiring: No.Hydromassage Bathtubs No.of Motors Total HP No.of Devices or Equivalent OTHER:roof mounted pv solar panels-4.800Kw system- 12 total panels- 200A- NO ESS Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: 26,937.60 (When required by municipal policy.) Work to Start:upon approval Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ❑ BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Freedom Forever Massachusetts LLC LIC.NO.:902A1 Licensee: Matthew Markham Signature LIC.NO.:1136MR 774-320-5539 Address: (Ifapplicable,enter "exempt"in the license number line.) Bus.Tel.No.: A 135 Robert Treat Paine Dr.,Taunton,MA 02780 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent.I Owner/Agent Telephone No. I PERMIT FEE: $ Signature PHOTOVOLTAIC SYSTEM CODES: CONSTRUCTION NOTES: THIS PROJECT COMPLIES WITH THE FOLLOWING: 2015 INTERNATIONAL BUILDING CODE CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ,��OF dfq ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. SS 2015 INTERNATIONAL RESIDENTIAL CODE q 2018 INTERNATIONAL MECHANICAL CODE ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT JOSEPH J. '-G 2018 INTERNATIONAL PLUMBING CODE BRAVO POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE = V'; 2018 INTERNATIONAL FUEL GAS CODE MOUNTED. c`o) ELECTRICAL 2018 INTERNATIONAL ENERGY CONSERVATION CODE No. 56193 2015 INTERNATIONAL EXISTING BUILDING CODE MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN - ,pF�/��&p ,�4 ACCORDANCE WITH UL 2703.SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER 'FS e:`�` 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE a0ttALE; 2020 NATIONAL ELECTRICAL CODE SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. r n AS ADOPTED BY TOWN OF YARMOUTH (MA) DIG ALERT(811)TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY ` f �' EXCAVATION TAKING PLACE ! PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM DC DISCONNECT/INVERTER AS PER 2020 NEC SEC 250.166(A). SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH VICINITY MAP: REQUIREMENTS OF ART.690 OF THE 2020 NEC THE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM vrnroek bCLIENT: JOYCE MARIA cce r INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT 107 MERCHANT AVENUE,YARMOUTH,MA �e ATTACHED TO THE ROOF USING CONDUIT MOUNT. AH.TOWN OF YARMOUTH(MA) UTILITY:EVERSOURCE ENERGY(EASTERN MA) METER:2370440 PHONE:(508)498-8864 ra .y ( 1z7! .a"t CC tee! ::n PC=t_. e Tey '/JO! .g) M,ereYSTEM: ;r 9 SYSTEM SIZE(DC):12 X 400=4.800 kW SYSTEM SIZE(AC):3.480 kW @ 240V MODULES:12 X HANWHA QCELL:Q.PEAK ia`' b DUO BLK ML-G10+400 F.05 \<'' 4' MICROINVERTERS:12 X ENPHASE 43 e I IQ7PLUS-72-2-US[240V] e PEAK OUTPUT:12 X 295=3,540VA O 2 MAX OUTPUT:12 X 290=3,480VA 0 a' g SITE LOCATION TABLE OF CONTENTS: _. ---2-3- PV-1 SITE LOCATION REVISIONS PV-2 SITE PLANDS7 1 M.C. 8/16/2022 NO. REVISED BY DATE PV-2A ROOF PLAN WITH MODULES LAYOUT 6 0 t PV-2B STRUCTURAL CALCULATIONS - - PV-3 MOUNTING DETAILS _ Ss` PV-4 THREE LINE DIAGRAM FOREVER 1 PV-5 CONDUCTOR CALCULATIONS FREEDOM FOREVER LLC 135 ROBERT TREAT PAINE DR.,TAUNTON, PV-5A PANEL SCHEDULE MA 02780 Tel:(800)385-1075 PV-6 EQUIPMENT&SERVICE LIST GREG ALBRIGHT PV-7 LABELS PV-7A SITE PLACARD iih,., G"�'�( PV-8 MICROINVERTER CHART CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; PV-9 SAFETY PLAN BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISOR PV-10 SAFETY PLAN LICENSE CS-111662;MASTER ELECTRICIAN 1136 MR APPENDIX MANUFACTURER SPECIFICATION SHEETS SITE LOCATION • JOB NO: DATE: DESIGNED BY: SHEET: 240218 8/16/2022 M.C. PV-1 E - Z 3 - oo/0c7 BARUN CORP August 15,2022 RE: CERTIFICATION LETTER Project Address: JOYCE MARIA RESIDENCE 107 MERCHANT AVENUE YARMOUTH,MA 02675 Design Criteria: -Applicable Codes=2015 IBC/IEBC W/(780 CMR)9th Edition,2015 IRC W/(780 CMR)9th Edition,ASCE 7-10 and 2015 NDS -Risk Category=II -Wind Speed=140 mph,Exposure Category B,Partially/Fully Enclosed Method -Ground Snow Load=30 psf -Roof 1:2 x 10 @ 16"OC,Roof DL=16 psf,Roof LL/SL=20 psf(Non-PV),Roof LL/SL=10.8 psf(PV) To Whom It May Concern, A structural evaluation of loading was conducted for the above address based on the design criteria listed above. Existing roof structural framing has been reviewed for additional loading due to installation of Solar PV System on the roof.The structural review applies to the sections of roof that is directly supporting the Solar PV System. Based on this evaluation,I certify that the alteration to the existing structure by installation of the Solar PV System meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,the Solar PV System assembly including attachment hardware has been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed the requirements set forth by the referenced codes. jN OF MAs,q Sincerely, n uR C i C�/ Digitally signed by HUM n HUMPHREY K KARIUKI • "uMP"ReY K O KAR N0. 9IUKI K KARIUKI Date: 2022.08.16 U STRUCT br 14:35:13 -04'00' /ONAL 04 STRUCT ' • 1 ONLY t .r s, r ,.,,. 292 4506 ; , .,rr, r,r BARUN CORP RESULTS SUMMARY JOYCE MARIA RESIDENCE,107 MERCHANT AVENUE,YARMOUTH,MA 02675 MOUNTING PLANE STRUCTURAL EVALUATION ROOF PITCH MOUNTING PLANE (deg.) RESULT GOVERNING ANALYSIS Roof 1 44° OK IEBC IMPACT CHECK STANDOFF HARDWARE EVALUATION FOR WIND UPLIFT MOUNTING PLANE WIND UPLIFT DCR Roof 1 57.5% Limits of ScqQpL Work and Liability: The existing structure has been reviewed based on the assumption that it has been originally designed and constructed per appropriate codes. The structural analysis of the subject property is based on the provided site survey data. The calculations produced for this structure's assessment are only for the roof framing supporting the proposed PV installation referenced in the stomped ph-wiser and were made according to generally recognized structural analysis standards and procedures. All PV modules, racking and attachment components shall be designed and installed per manufacturer's approved guidelines and specifications. These piC117s are not stomped for water leakage or existing damage to the structural component that WC15 not accessed during the site survey,Pgar to commencement of work, the Pt'system instolier should verify that the existing roof and connections ore in suitable condition and inspect framing noted on the certification letter and inform the Engineer of Record of any discrepancies prior to installation. the installer should also check for any dominoes such or water damage, cracked framing, etc, and inform the Engineer of Record of misting deficiencies which are unknown and/or were not observable Miring the time of survey and have not been included in this scope of work, Any change in the'dope of thn work shall not he accepted unless such change,addition,or deletion is approved in advance and in writing by the Engineer of iiheand. Boron tlrsrisi Design and Engine:none 610,202.4506 henek,daanarunsniarrecoso, wane.rasian-horpdadie BARUN CORP LOAD CALCULATION Roof 1 JOYCE MARIA RESIDENCE,107 MERCHANT AVENUE,YARMOUTH,MA 02675 PV PANELS DEAD LOAD(PV-DL) PV Panels Weight = 2.50 psf Hardware Assembly Weight = 0.50 psf Total PV Panels Weight PV-DL= 3.00 psf ROOF DEAD LOAD(R-DL) Existing Roofing Material Weight Flat Tile Roof 1 Layer(s) = 10.00 psf Underlayment Weight = 0.50 psf Plywood/OSB Sheathing Weight = 1.50 psf Framing Weight 2 x 1t}@ 16'in.0.C. = 2.89 psf No Vaulted Ceiling = 0.00 psf Miscellaneous = 1.50 psf Total Roof Dead Load R-DL= 16.40 psf REDUCED ROOF LIVE LOAD(Lr) Roof Live Load Lo= 20.00 psf Member Tributary Area At< 200 ft2 Roof 1 Pitch 44°or 12/12 Tributary Area Reduction Factor R1= 1.00 Roof Slope Reduction Factor R2= 0.63 Reduced Roof Live Load,Lr=Lo(R1)(R2) Lr= 12.50 psf SNOW LOAD Ground Snow Load pg= 30.00 psf Effective Roof Slope 44° Snow Importance Factor Is= 1.00 Snow Exposure Factor Ce= 1.00 Snow Thermal Factor Ct= 1.10 Minimum Flat Roof Snow Load pf-min= 25.00 psf Flat Roof Snow Load pf= 25.00 psf SLOPED ROOF SNOW LOAD ON ROOF(Non-Slippery Surfaces) Roof Slope Factor Cs-roof= 0.80 Sloped Roof Snow Load on Roof ps-roof= 20.00 psf SLOPED ROOF SNOW LOAD ON PV PANELS(Unobstructed Slippery Surfaces) Roof Slope Factor Cs-PV= 0.43 Sloped Roof Snow Load on PV Panels ps-PV= 10.80 psf i i..,.. i3 IE':,31' .. ?Pi e. i !c _k.� f, ^ ' ���� �������� ����� � � ��8 8A� CORP������8� ������U— Roof 1 JoYcsmxmx RESIDENCE,zur MERCHANT AVENUE,YAnMour*'Mxozs7s sX|yT|ma WITH PvPANELS Roof Dead Load(oL)~ 16.40 19.40 n,r Roof Live Load(L,)~ 12.50 ».»» nsf Roof Snow Load(sL)~ 20.00 m.»o n'' sx|ST|mG WITH pvPANELS (nL+L,)/cu~ 23.12 21.56 pSf (oL+sU/Ca= 31.65 26.26 nm Maximum Gravity Load= 31.65 uozo nsf Load Increase(%)~ 'o.oym OK |sac Provision: 2015 The requirements of section 807.4 of 2015 lEBC are met and the structure is permitted to remain unaltered. Bamn �nm| Dn�i8n wnd Eng|noohng | 8102O24�OG � ohn»k��Uamn-corpoom | v�»w �mn~orp BARU N CORP WIND UPLIFT CALCULATION Roof 1 JOYCE MARIA RESIDENCE,107 MERCHANT AVENUE,YARMOUTH,MA 02675 SITE INFORMATION Ultimate Wind Speed= 140.00 mph Roof Pitch= 44' Risk Category= II Roof Type= Gable Exposure Category= B Wind Directionality Factor,Kd= 0.85 Mean Roof Height= 25.00 ft Topographic Factor,Kzt= 1 Solar Array Dead Load= 3.00 psf Velocity Pressure Exposure Coeff.,Kz= 0.67 DESIGN CALCULATIONS Wind Velocity Pressure(qh)=0.00256*Kz*Kzt*Kd*Ke*V2= 28.36 psf a(ft)= 4.50 Array Edge Factor(yE)= 1.50 Solar Array Pressure Equalization Factor(ya)= 0.60 Hardware Type: Ecofasten Racking System Allowable Load= 655.00 lbs SPF,2.5"lag embedment Max.X-Spacing(Zone 1-2r) 4.00 ft Effective Wind Area Max.Y-Spacing(Zone 1-2r) 3.42 ft 13.68 ft2 Max.X-Spacing(Zone 2n&3r) 3.00 ft Effective Wind Area Max.Y-Spacing(Zone 2n&3r) 3.42 ft 10.26 ft2 Max.X-Spacing(Zone 3e) 3.00 ft Effective Wind Area Max.Y-Spacing(Zone 3e) 3.42 ft 10.26 ft2 ROOF ZONE GCp(-)UPLIFT UPLIFT PRESSURE PULLOUT FORCE 1-2r -1.66 -24.19 psf 330.92 lbs 2n&3r -1.99 -29.21 psf 299.66 lbs 3e -2.48 -36.72 psf 376.76 lbs NOTE: •Wind calculation is based on ASCE 7-16,29.4-C&C,LC#7:0.6D+0.6W is used. Brtjn C Prc-3vii; 1;-;;OACCPrIJ ; 61') r,Gri LEGEND: TRANSFORMER LOCATION UNKNOWN. CHIMNEY ----------- - - ----------- 121'-5" 0 PIPE VENT �- - — ir �OF�/,1ss9 MODULES -- — — � JOSEPH OJ. �y------7 � - — -- CONDUIT I `) No. 56193L 1 'tFGISTE0,4 SETBACK '2' '`S/ONALO AC AC DISCONNECT (,:.,;:1-14 "^' UM UTILITY METER / 7 PM PRODUCTIONI _ METER JUNCTION BOX ' JB I BLP BACKUP LOAD ROOF AREA:2374.41 SO FT PANEL I / CLIENT: TBG TESLA BACKUP JOYCE MARIA GATEWAY 2 1 (N)TESLA BACKUP GATEWAY 107 MERCHANT AVENUE,YARMOUTH,MA (N)UTILITY DISCONNECT EATON DG221URB 02675 (OR ALENT) AHJ:TOWN OF YARMOUTH(MA) TPW TESLA UTILITY:EVERSOURCE ENERGY(EASTERN POWERWALL 2 (N)PRODUCTIONEQUIVMETER MA) (N)COMBINER BOX PHONE:(508)498-8864 METER:2370440 CB COMBINER BOX 44'-4,. (N)TESLA POWERWALL 1 — SYSTEM: I 11112mm {_ SYSTEM SIZE(DC):12 X 400=4.800 kW (N)JUNCTION BOX W SYSTEM SIZE(AC):3.480 kW @ 240V / a MODULES:12 X HANWHA QCELL:Q.PEAK l6 DUO BLK ML-G10+400 ' MICROINVERTERS 12 X ENPHASE I IQ7PLUS-72-2-US 1240V] PEAK OUTPUT:12 X 295=3,540VA MAX OUTPUT:12 X 290=3,480VA I IIII ' LIF !IC- -12- -- -r (E)BACKUP LO�n PANEL il / II ›- cr W / MIMI - REVISIONS .A _ NO._ REVISED BY DATE ' � 1 M.C. 8/16/2022 �LN 1 a IL _ • et I I F O R{V F R 0111 FREEDOM FOREVER LLC 00 135 ROBERT TREAT PAINS DR.,TAUNTON, (N) 12 HANWHA QCELL: Q.PEAK DUO BLK MA 02780 ML-G10+400 WITH ENPHASE Tel:(800)385-1075 IQ7PLUS-72-2-US[240V] (E)UTILITY METER ON PEDESTAL GREG ALBRIGHT CV ---------------__ )3),-,/ C/14/4-- - I HOME IMPROVEMENT OCONTRACTR SOR 198080; —�- _ ® BUSINESS ELECTRICAL CONTRACTOR LICENSE MERCHANT AVENUE - _ _ LICENSE CS-111662;CONSTRUCTION SUPERVISOR U ELECTRICIAN COIAN SITE PLANCO 1136 MR 41111 r SCALE: 1/16" = I-0" SITE PLAN JOB NO: DATE: DESIGNED BY: SHEET: 240218 8/16/2022 M.C. PV-2 (N)TESLA BACKUP GATEWAY LEGEND: (N)AC DISCONNECT EATON DG221URB(OR EQUIVALENT) OA' OF MgSS,9 CHIMNEY (N) C. PRODUCTION METER �� °ti u (N)COMBINER BOX HUMPHREY K. m 0 PIPE VENT (N)TESLA POWERWALL U STRUCT KARIUKI 71 L` -6 NO. . 93 i 4 MODULES ®m . !-.N.,,i 162,4.TE� rs, — --- — CONDUIT ®�� %NAL E-N (N)JUNCTION BOX ONLYSTRUT ONLY SETBACK ly signed by AC AC DISCONNECT H U M PH REY DigitaHUMPIHREY K KARIUKI UM UTILITY METER K KARIUKI Date:2022.08.16 14:35:46-04'00' PM PRODUCTION METER JB JUNCTION BOX BLP BACKUP LOAD ROOF AREA:2374.41 SQ FT PANEL (E) BACKUP LOAD PANEL CLIENT: TBG TESLA BACKUP JOYCE MARIA GATEWAY 2 ftl 107 MERCHANT AVENUE,YARMOUTH,MA 02675 AHJ:TOWN OF YARMOUTH(MA) TP TESLA UTILITY:EVERSOURCE ENERGY(EASTERN MA POWERWALL 2 ) METER:2370440 PHONE:(508)498-8864 - W CB COMBINER BOX ® SYSTEM: SYSTEM SIZE(DC):12 X 400=4.800 kW SYSTEM SIZE(AC):3.480 kW @ 240V MODULES:12 X HANWHA QCELL:O.PEAK DUO BLK ML-G10+400 MICROINVERTERS:12 X ENPHASE IQ7PLUS-72-2-US[240V] PEAK OUTPUT:12 X 295=3,540VA MAX OUTPUT:12 X 290=3,480VA (N) 12 HANWHA QCELL: Q.PEAK DUO REVISIONS BLK ML-G10+400 WITH ENPHASE NO. REVISED BY DATE IQ7PLUS-72-2-US [240V] 1 M.C. 8/16/2022 • Wee iLll R OREVER FREEDOM FOREVER LLC 135 ROBERT TREAT PAINE DR.,TAUNTON, MA 02780 Tel:(800)385-1075 GREG ALBRIGHT ci 1/44-1 (E)UTILITY METER ON PEDESTAL iii,,,/ U CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; ® BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISOR `�� ROOF PLAN NOTES: LICENSE CS-111662;MASTER ELECTRICIAN ��� CID 1. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS 1136 MR SCALE: 1/8" = I-0" 2. ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES ROOF PLAN WITH MODULES LAYOUT 3. JUNCTION BOX IS MOUNTED TO THE RAIL. JOB NO: DATE: DESIGNED BY: SHEET: 240218 8/16/2022 M.C. PV-2A • CN OF MASS O�� •IQ HUMPHREY K. % KARIUKI -4 U STRUCT NO. . 9 1 A,!.;i_:.TEFL 4(1 \_ S/ONAL ENG ROOF DETAILS: STRUCT TOTAL ROOF AREA: 2374.41 SQ FT ARRAY COVERAGE: 10.68% SYSTEM DISTRIBUTED WEIGHT: 2.29 LBS SFM INFINITY\ ROCKIT MICRORAIL POINT-LOAD: 12.94 LBS ROOF AREA STATEMENT CLIENT: JOYCE MARIA ROOF MODULE QUANTITY ROOF PITCH ARRAY PITCH AZIMUTH ROOF AREA ARRAY AREA 107 MERCHANT AVENUE,YARMOUTH,MA 02675 1 12 44° 44° 189° 510.74 SQ FT 253.68 SQ FT AHJ:TOWN OF YARMOUTH(MA) UTILITY:EVERSOURCE ENERGY(EASTERN MA) METER:2370440 PHONE:(508)498-8864 SYSTEM: SYSTEM SIZE(DC):12 X 400=4.800 kW SYSTEM SIZE(AC):3.480 kW @ 240V MODULES:12 X HANWHA QCELL:Q.PEAK DUO BLK ML-G10+400 MICROINVERTERS:12 X ENPHASE IQ7PLUS-72-2-US[240V) PEAK OUTPUT:12 X 295=3,540VA MAX OUTPUT:12 X 290=3,480VA REVISIONS NO. REVISED BY DATE 1 M.C. 8/16/2022 d nil OR1VEP FREEDOM FOREVER LLC 135 ROBERT TREAT PAINE DR.,TAUNTON, MA 02780 Tel:(800)385-1075 Gif REG ALBRIGYHT ;, f)� CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-Al;CONSTRUCTION SUPERVISOR LICENSE CS-111662,MASTER ELECTRICIAN 1136 MR ROOF DETAILS JOB NO: DATE: DESIGNED BY: SHEET: 240218 8/16/2022 M.C. PV-2B �v-oµOFM'q,, ' S9oy O' G a ' i t ! I HUMPHREY K. m i I i , ! ! 8 ! , 1 t 0 KARIUKI - U ` 3 STRUCT L , a E ! NO. . 93 i n i t + I t ! F ! i i a .,y, I , �,A 0 1=w.TER . S/ONAL ENG STRUCT ''.• ONLY . • i'...i',...,.. CLIENT: JOYCE MARIA 107 MERCHANT AVENUE,YARMOUTH,MA MAX ATTACHMENT SPAN - 4' STAGGERED 02675 AHJ:TOWN OF YARMOUTH(MA) UTILITY:EVERSOURCE ENERGY(EASTERN PARTIAL ROOF FRAMING PLAN MA)METER:2370440 Scale: NTS PHONE:(508)498-8864 SYSTEM: SYSTEM SIZE(DC):12 X 400=4.800 kW SYSTEM SIZE(AC):3.480 kW @ 240V MODULES:12 X HANWHA QCELL:Q.PEAK DUO BLK ML-G10+400 MICROINVERTERS:12 X ENPHASE IQ7PLUS-72-2-US 1240V) HANWHA QCELL:Q.PEAK DUO PEAK OUTPUT:12 X 295=3,540VA SUB FLASHING(OPTIONAL) O.. HANWHA QCELL:Q.PEAK DUO BLK ML-G10+ BLK ML-G10+400 MAX OUTPUT:12 X 290=3,480VA SFM INFINITY\ROCKIT RAIL-LESS 491°M INFINITY\ROCKIT HANWHA QCELL:Q.PEAK DUO UNIRAC SOLAR HOOK TYP. A RAIL LESS �� SFM INFINITY\ROCKIT RAIL LESS BLK ML G10+400 (E)FLAT TILE (E)FLAT TILE FLAT TILE + 11111111111 eidoriiiii0li It4 UNIRAC SOLAR HOOK �y__�_ �1L._.A X —, UNIRAC SOLAR HOOK TYP REVISIONS 0 W, 1I/ NO. REVISED BY DATE2 O C' �.- SUB FLASHING(OPTIONAL) 'I''- SUB FLASHING(OPTIONAL) 1 M.C. 8/16/2022 �_ 1�Rp` a"x3.5"SS LAG BOLT - - - �� 2X WITH MIN.2}'EMBEDMENT, SEALED PENETRATION a"x 3.5"SS LAG BOLT WITH MIN.2 i"EMBEDMENT, r SEALED PENETRATION • • tCi eel (E) 2X10 RAFTER @ 16" (E) 2X10 RAFTER @ 16"O.C. F O R E V EF O.C. FREEDOM FOREVER LLC 135 ROBERT TREAT PAINE DR.,TAUNTON, MA 02780 Tel:(800)385-1075 GREG ALBRIGHT CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISOR LICENSE CS-111662,MASTER ELECTRICIAN SOLAR PV ARRAY SECTION VIEW I ATTACHMENT DETAIL 1136 MR Scale: NTS I Scale: NTS MOUNTING DETAILS JOB NO: DATE: DESIGNED BY: SHEET: 240218 8/16/2022 M.C. PV-3 <"' Of tl,)SSq JJOSEPH J. c. o BRAVO rn ELECTRICAL No. 56193 ti V> r: 'r£S ONAtEj I BRANCH HRSB1#6 AWG,BARE TO (N)TESLA GATEWAY 2 LES INTEGRAL CLIENT: JOYCE MARIA COPPER GROUND 200A RATED,NEMA 3R 107 MERCHANT AVENUE,YARMOUTH,MA 200A MAIN SERVICE DISCONNECT 02675 AHJ:TOWN OF YARMOUTH(MA) 200A/2P (NI MILBANK U5929-XL-INS SINGLE (N)30A RATED — (E)UTILITY METER UTILITY:EVERSOURCE ENERGY(EASTERN ENPHASE 107PLUS-72-2-US(240V1 JUNCTION: (N)ENPHASE PHASE NEMA 3R 600V/100A FORM 2S AC DISCONNECT '' T ,,T,„____MA) MICROINVERTERS BOX COMBINER BOX SMART PRODUCTION METER EATON DG221URB(OR - - o/`o-- METER:2370440 NEMA 3R EQUIVALENT) •4.0 0 0• O (N))20A o PHONE:(508)498-8864 STRING-1 .. -�1---i ' i , , __ • \-a 1 o- 12 HANWHA°CELL:Q.PEAK DUO BLK NV a - 'l -il o ML-G10+400 1 --_ -] (N)20A/2P 1 ____ ____ ___T___ CI C r 1 L _ I - SYSTEM: SYSTEM SIZE(DC):12 X 400=4.800 kW z-#1oAwc,rHwN-z SYSTEM SIZE(AC):3.480 kW @ 240V MODULES:12 X HANWHA QCELL:Q.PEAK 1-#8 EGC,THWN-2 3-#10 AWG,THWN-2 N 30A - DUO BLK ML-G10+400 IN 3/4"EMT CONDUIT 1-#3 EGC,THWN-2 (/)T� IN 3/4"OR LARGER EMT CONDUIT o o— MICROINVERTERS:12 X ENPHASE i-• \-0 `o_ ' IQ7PLUS-72-2-US[240V] r -} I PEAK OUTPUT:12 X 295=3,540VA I MAX OUTPUT:12 X 290=3,480VA L___ •- --000000 r —3-#2/OAWG,THWN-2 IN 1-1/2"OR LARGER EMT CONDUIT I COMPLIES WITH SUM OF ALL BREAKERS RULE (E)200A BACKUP REVISIONS LOAD CENTER NO. REVISED BY DATE (N)TESLA POWERWALL 2, TESLA - (E)200A _ 1 M.C. 8/16/2022 5KW,13.5KWH NEMA 3R UL }_ n _ _ _ LISTED WITH TERMINAL _ _ _ d l SWITCH,BATTERY/ T r J - INVERTER,1201240V- t3-#10 AWG,THWN- j Er. 1-#8 EGC,THWN 2 ' 3-#2,0 AWG,THWN-2 sage s Ai...g, _ 2-PAIR#18 AWG STRANDED . 1-#8 EGC,THWN-2 '00 F 0 8 E',/E F. IN 3/4"OR LARGER EMT -.-/ IN 1-1/2"OR LARGER FREEDOM FOREVERLC CONDUIT o it EMT CONDUIT 135 ROBERT TREAT PAINE DR.,TAUNTON, MA 02780 Tel:(800)385-1075 GREG ALBRIGHT i .) A - i)v.," U I,. CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISOR LICENSE CS-111662;MASTER ELECTRICIAN NOTE: 1136 MR CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT THREE LINE DIAGRAM TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS JOB NO: DATE' DESIGNED BY: SHEET: 240218 8/16/2022 M.C. PV-4 �_.\\10F 1lgs3q , t JOSEPH- q BRAVO �, C1-1 ELECTRICAL No. 56193 t'' SIONAL /ViYill WIRE SCHEDULE CLIENT: JOYCE MARIA STARTING ADJUSTMENT MAXIMUM 107 MERCHANT AVENUE,YARMOUTH,MA STARTING TEMPERATURE ADJUSTED 02675 AWG CURRENT FACTOR FOR CURRENT AHJ:TOWN OF YARMOUTH(MA) RACEWAY CONDUCTOR ALLOWABLE CORRECTION CONDUCTOR EQUIPMENT WIRE LOCATION WIREAPPLIED TO MORE THAN 3 APPLIED TO UTILITY:EVERSOURCE ENERGY(EASTERN # QTY. SIZE AMPACITY @ 90°C CONDUCTORS FACTOR CONDUCTORS AMPACITY CONDUCTORS 310.15(8)(16) IN RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) @ 90°C IN RACEWAY METER:2370440 PHONE:(508)498-8864 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 10 40 13.93 1 1 40.00 17.41 2 AC MICROINVERTER TO JUNCTION BOX ROOF/FREE-AIR 2 10 40 14.52 1 1 40.00 18.15 - 3 AC JUNCTION BOX TO ENPHASE COMBINER BOX EXTERIOR WALL 2 10 40 14.52 1 1 40.00 18.15 SYSTEM: SYSTEM SIZE(DC):12 X 400=4.800 kW 4 AC ENPHASE COMBINER BOX TO PRODUCTION METER EXTERIOR WALL 3 10 40 14.52 1 1 40.00 18.15 SYSTEM SIZE(AC):3.480 kW @ 240V MODULES:12 X HANWHA QCELL:Q.PEAK 5 AC PRODUCTION METER TO AC DISCONNECT EXTERIOR WALL 3 10 40 14.52 1 1 40.00 18.15 DUO BLK ML-G10+400 MICROINVERTERS:12 X ENPHASE 6 AC AC DISCONNECT TO TESLA BACKUP GATEWAY 2 EXTERIOR WALL 3 10 40 14.52 1 1 40.00 18.15 IO7PLUS-72-2-US[240V] PEAK OUTPUT:12 X 295=3,540VA 7 AC TESLA POWERWALL TO TESLA BACKUP GATEWAY 2 EXTERIOR WALL 3 10 40 22.00 1 1 40.00 27.50 MAX OUTPUT:12X290=3,480VA 8 AC BACKUP LOAD CENTER TO TESLA BACKUP GATEWAY 2 EXTERIOR WALL 3 2/0 195 200.00 1 1 195.00 200.00 9 AC TESLA BACKUP GATEWAY 2 TO UTILITY METER EXTERIOR WALL 3 2/0 195 200.00 1 1 195.00 200.00 REVISIONS NO. REVISED BY DATE - 1 M.C. 8/16/2022 . '€>Ae L FOREVER FREEDOM FOREVER LLC 135 ROBERT TREAT PAINE DR.,TAUNTON, MA 02780 Tel:(800)385-1075 GREG ALBRIG. jj HT rl 1 CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISOR LICENSE CS-111662;MASTER ELECTRICIAN 1136 MR CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. CONDUCTOR CALCULATIONS JOB NO: DATE: DESIGNED BY: SHEET: 240218 8/16/2022 M.C. PV-5 OFllg(---fk-ii . 9JOSEPH J''BRAVO `IP ri o ELECTRICAL -' No. 56193 ") (14:y,„,,„efidczit // aft I BACKUP LOAD PANEL SCHEDULE 200Al2P MAIN BREAKER CLIENT: JOYCE MARIA 107 MERCHANT AVENUE,YARMOUTH,MA LOAD BREAKER RATING BREAKER RATING LOAD 02675 AHJ:TOWN OF YARMOUTH(MA) UTILITY:EVERSOURCE ENERGY(EASTERN MA) ILLEGIBLE 2 ON 1 P 20,41 P R EI-ER METER:2370440 PHONE:(508)498-8864 PUMP 2ON1P 2ON1P BATH GFI _ SYSTEM: DIN. AREA GFI 2ON1P 20Al1P WASHER/DRYER SYSTEM SIZE(DC):12 X 400=4.800 kW SYSTEM SIZE(AC):3.480 kW @ 240V MODULES:12 X HANWHA°CELL:O.PEAK DIN APPL/KIT GFI 2OAd1P 20A11P 'DIN RM PLUGS DUO BLK ML-G10+400 MICROINVERTERS:12 X ENPHASE IQ7PLUS-72-2-US[240V] MICRO 20A/1P 15 A!1 P FL0 G D,'HAL LILAI I N D RY PEAK OUTPUT:12 X 295=3,540VA MAX OUTPUT:12 X 290=3,480VA t1ID D LE 15N1P 15N1P 2NDFL MD BATH FURNACE 15N1P 15N1P 2ND FL MD FRONT B IvTf BACK 15A/1P 15A/1P 2ND FL MD SMOKES .. ... .. REVISIONS BSMT7FIRE PLACE 15N1P 20A11P GARAGE REFER NO. REVISED BY DATE 1 M.C. 8/16/2022 MAST BDRMIBATH 15NIP 2ON1P GARAGE GFI - - - KIT1DIN/RECJFLGOD 15N1P 15N1P :DISHWASHER € ' F O R i k,E k FRONT /� �j ) 7 p p� FREEDOM FOREVER LLC FROI\J 15N1P 40 N2P 'S UBPJ NEL 135 ROBERT TREAT PAINE DR.,TAUNTON, MA 02780 Tel:(800)385-1075 GREG ALBRIGHT A )31,,..../ A •1-- CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-Al;CONSTRUCTION SUPERVISOR LICENSE CS-111662,MASTER ELECTRICIAN 1136 MR PANEL SCHEDULE JOB NO: DATE: DESIGNED BY: SHEET: 240218 8/16/2022 M.C. PV-5A BREAKER SIZES: SERVICE LIST: 20A PV BREAKER NONE 20A PV BREAKER A PV BREAKER A PV BREAKER .. r Z�0F1�,gss9EPH J. 'oRAVO ELECTRICAL No. 56193 Jc j� Sp /ONALV�',.• . mtilli MATERIAL LIST: QTY. PART PART# DESCRIPTION 12 MODULES PV-111-400W-2 HANWHA QCELL:Q.PEAK DUO BLK ML-G10+400 1 JUNCTION BOX 480-276 600VDC NEMA 3R UL LISTED JUNCTION BOX 4 CONNECTORS 240-300 STAUBLI/MULTI-CONTACT MC4 CONNECTORS(FEMALE) 4 CONNECTORS 240-301 STAUBLI/MULTI-CONTACT MC4 CONNECTORS(MALE) 12 MICROINVERTER(S) 120-011 ENPHASE IQ7PLUS-72-2-US[240V)UL 62109-1 LISTED MICROINVERTER W/PV RAPID SHUT DOWN EQUIPMENT 1 ENVOY 160-100 "ENPHASE AC COMBINER W/ENVOY PCB,80A" 14 Q CABLE 160-106 "ENPHASE,Q CABLE PORTRAIT FOR 60/72 CELL" CLIENT: 14 Q CABLE 160-105 "ENPHASE,Q CABLE LANDSCAPE 60 CELL" JOYCE MARIA 107 MERCHANT AVENUE,YARMOUTH,MA 1 COMBINER BOX 160-100 ENPHASE COMBINER BOX NEMA 3R RATED 02675 1 CABLE 310-300 "ENPHASE,RAW TRUCK CABLE(300 FT.ROLL)" AHJ:TOWN OF YARMOUTH(MA) UTILITY:EVERSOURCE ENERGY(EASTERN 96 CLIP 160-108 ENPHASE TIE WRAPS/CABLE CLIPS MA) 3 SEAL 160-107 ENPHASE SEALING CAPS FOR Q CABLE METER:2370440 2 TERMINATOR 160-109 ENPHASE TERMINATOR PHONE:(508)498-8864 1 DISCONNECT 261-526 ENPHASE DISCONNECT TOOL 1 TESLA POWERWALL 141-000 TESLA:POWERWALL 2 1 TESLA BACKUP GATEWAY 161-000 TESLA BACKUP GATEWAY 2 SYSTEM: 1 (PW)INTERNAL GEN PANEL BUG2 INTERNAL PANELBOARD(CONFIG:GENERATION PANEL) SYSTEM SIZE(DC):12 X 400=4.800 kW 1 AC DISCONNECT 321-030 30A RATED 240VAC NEMA 3R UL LISTED SYSTEM SIZE HA WH Q E L:CL MODULES:12 X HANWHA QCELL:Q.PEAK 1 PRODUCTION METER 322-100 MILBANK U5929-XL-INS SINGLE PHASE NEMA 3R 600V/100A FORM 2S DUO BLK ML-G10+400 1 CLOSING PLATE 322-302 MILBANK METER CLOSING PLATE(USED WITH U5929-XI) MICROINVERTERS:12 X ENPHASE IQ7PLUS-72-2-US 1240V) 45 ROOF ATTACHMENT 1 261-602 SFM INFINITY\ROCKIT MICRORAIL PEAK OUTPUT:12 X 295=3,540VA 9 SFM TRIM 1 241-253 FLASHKIT SFM/ROCK-IT TRIM COMP DARK MAX OUTPUT:12 X 290=3,480VA -23 SFM SLIDER 1 261-603 FLASHKIT SFM/ROCK-IT SLIDER COMP DARK 7 BONDING CLAMP 1 221-100 N/S BONDING CLAMP 3 BONDING CLAMP 1 241-404 TRIM BONDING CLAMP 13 MOUNT ASSEMBLY 1 241-405 MLPE MOUNT ASSY 8 SFM SPLICE 1 261-604 SFM/ROCK-IT SPLICE 2 SFM ATTACHED SPLICE 1 211-101 ATTACHED SPLICE 8 INCH 10 TRIMRAIL 1 261-606 TRIMRAIL UNIV CLIP W/HDW REVISIONS 3 TRIM SPLICE 1 261-605 TRIM SPLICE DRK NO. REVISED BY DATE 6 TRIMRAIL 1 211-115 TRIMRAIL UNIV DRK 1 M.C. 8/16/2022 12 GROUND LUG 1 260-585 ILSCO GROUND LUG - - 12 TRIM END CAPS 1 221-200 UNIRAC SFM /ROCK-IT TRIM END CAPS FORIVEP FREEDOM FOREVER LLC 135 ROBERT TREAT PAINE DR.,TAUNTON, MA 02780 Tel:(800)385-1075 GREG ALBRIGHT 1 h1,-,/ ki '1-1 CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISOR LICENSE CS-111662;MASTER ELECTRICIAN 1136 MR EQUIPMENT&SERVICE LIST JOB NO: DATE: DESIGNED BY: SHEET: 240218 8/16/2022 M.C. PV-6 i► 1M.+11�. I?_:©F -1► NOTES: ;�` p ITI SOLAR PV SYSTEM EQUIPPED 1. NEC ARTICLES 690 AND 705 AND IRC SECTION R324 690.13(B) .11 WITH RAPID SHUTDOWN MARKINGS SHOWN HEREON. _ 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: I D ,© (� 11. D ,O 0 G 1 i G` r ► A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR ' �OF;If iii- +1 !w 1L(® '_ I ► TURN RAPID MACHINE PRINTED LETTERS OR ELECTRO PLATING. rSEPH Jssq��NEC 690.15(B)&NEC 69o.33(D)(2) B. RED BACKGROUND COLOR WHITE TEXT AND LINE o SHUTDOWN SWITCH TO WORK. RAVO "OFF" C. ARIAL FONT. o ELECTRICAL A WARNING A THE OFF POSITION TO 5 pVVpNELSIC 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN No. 56193 SHUT DOWN PV SYSTEM I THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE �O GrSTE�� <$ SINGLE 120-VOLT SUPPLY HAND-WRITTEN. .�` DO NOT CONNECT AND REDUCE SHOCK 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENTS IONAL � `, MULTIWIRE BRANCH CIRCUITS HAZARD IN THE ARRAY WITH POP-RIVETS OR SCREWS 1(;11/'f s�, J""^ 'r� NEC 710.15(C)&692.9(C) IFC 605.11.3.1(1)&690.56(C) AWARNING DUAL POWER SOURCE A CAUTION ION SECOND SOURCE IS PHOTOVOLTAIC SYSTEM SYSTEM CIRCUIT IS BACKFED y ��`{{ r rr // ` NEC 705.12(D)&NEC 690.59 PHOTOVOLTAIC NEC 705.12(D)&NEC 690.59 1 C P•.`'1 � � ti 'o f/A 1�`'1 A WARNING AWARNING L WARNING ARC FLASH AND SHOCK HAZARD POWER SOURCE OUTPUT '- !�{;�������� � � r TURN OFF PHOTOVOLTAIC - - - CONNECTION.DO NOT APPROPRIATE PPE REWIRED i v r C ��r '- NI n - I I AC DISCONNECT PRIOR TO 2.0 AT it IN.E3 RELOCATE THIS °:.11,REMOVED NEC �l �J ITA �. A A �+1 ( ) OVERCURRENT DEVICE. NEC 690.13 B Y. o C WORKING INSIDE PANEL 51 .. .,.....e _..�:.5 Y ,rjg��t "y� f m- --� NEC 705.12(C)&NEC 690.59 NEC 706.15(C)AND NEC 110.16 !F� nV 11'� 1'I f !© `� /'Yt - JO CE MARIA NEC 110.27(C)&OSHA 1910.145(F)(7) f [��`- 107 MERCHANT AVENUE,YARMOUTH,MA ['I rilo)l r' 1V `1 F%1 Ic -- 02675 A WARNING AHJ:TOWN OF YARMOUTH(MA) r` ..� E �,,\ / .ea} ( UTILITY:EVERSOURCE ENERGY(EASTERN ELECTRICAL SHOCK HAZARD 1 . 0 __ - NEC 690.53 METER 2370440 TERMINALS ON THQ 1fC- D C, 0 I' k 1 1 PHONE:(508)498-8864 LOAD SIDES MAY BE ENERGIZED NEC 690.13(B) A WARN I N G IN THE OPEN POSITION i. - y iV/ L7ELECTRICAL SHOCK HAZARD -y- 706.15(C)(4)&690.13(8) jf R/ � ] o !I 14.52A SYSTEM: TERMINALS ON THE LINE AND SYSTEM SIZE(DC):12 X 400=4.800 kW i 4 ,i: is 41#.6 I4t 041 11: i- SYSTEM SIZE A WARNING LOAD SIDES MAY BE ENERGIZED (AC):3.480 kW @ 240v a_ IN THE OPEN POSITION MODULES:12 X HANWHA OCELL:O.PEAK d silf,r,(I�i i, ofa 'fJl�:.is tl;) &a'xi: 24OV DUO BLK ML-G10+400 THIS EQUIPMENT FED BY DC VOLTAGE IS ALWAYS PRESENT MICROINVERTERS:12 X ENPHASE MULTIPLE SOURCES: �� WHEN SOLAR MODULES I07PLUS-72-2-US[240V] • NEC 690.54 ARE EXPOSED TO SUNLIGHT TOTAL RATING OF ALL OVERCURRENT PEAK OUTPUT:12 X 295=3,540VA DEVICES EXCLUDING MAIN POWER 706.15(C)(4)&690.13(B) MAX OUTPUT:12 X 290=3,480VA SUPPLY SHALL NOT EXCEED AWARNING DUAL POWER SOURCE AMPACITY OF BUSBAR NEC 705.12(6)(3)(3) SECOND SOURCE IS PHOTOVOLTAIC SYSTEM I Y A WARNING ► INVERTER NEC 705.12(D)&NEC 690.59 A WARNING � H.� CKHA � _ -- - - - -_ -- -- __ � _ -► � -__ ELECTRICAL SHOCK HAZARD - ► A DC J/B,� _ TERMINALS ON THE LINE AND THE DISCONNECTION OF THE g g � LOAD SIDES MAY BE ENERGIZED a 0 I©. C, t.._., _-_ ��I REVISIONS GROUNDED CONDUCTOR(S) T IN THE OPEN POSITION MAY RESULT IN OVERVOLTAGE EVERY 10'ON CONDUIT AND ENCLOSURES 706.15(C)(4)&690.13(B) NO. REVISED BY DATE ON THE EQUIPMENT NEC 690.31(0)(2) 1 M.C. 8/16/2022 NEC 690.31(E) - �f j� j i _��y Irl;:r0)1-145)YrialLffi i I'X01Y Y,� diuiFr A WARNING EVERY 10'ON CONDUIT AND ENCLOSURES I TURN OFF PHOTOVOLTAIC ( ' VER 0 hI , )! ) _ I'i NEC 690.31(D)(2) F R a c v E a 4 AC DISCONNECT PRIOR TO FREEDOM FOREVER LLC 135 ROBERT TREAT PAINE DR.,TAUNTON, WORKING INSIDE PANEL MA 02780 �I�I'�:411�iI ll�,tifi)�f3''l [ , Tel:(800)385-1075 690.56(0)(3) a60 iNEC 110.27(C)&OSHA 1910.145(F)(7) GREG ALBRIGHT ,I',I 4:40;1111-OI•�I4IF iloI a JOS I ,,' ARRAY •,t4,1:0-00. tl ), 1a1 iit. i`i a,p _ I V(�r ( H a,tl_>.'.<.c'1V�II..i.i..yao1:+•�t+P,1R-afh' i=t1:7;7dat+f•-`ac7ajk' I�i��'°t`S� ti -��._� 1 / U .1l1.') :; lz7aW IW- CONTRACTOR LICENSE: 'ct.:«-, ith, HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE rKi:(A.7oi4)a • a±+,:iin10(t •i6tl: 1.Z.,]t:+'r4ti.:• .TJt :- - 902-EL-A1;CONSTRUCTION SUPERVISOR LICENSE CS-111662;MASTER ELECTRICIAN tik+: a)- -r,i4ue#4-:1t41N 1136 MR 706.7(D) LABELS NEC 690.31(G)(3)&(4) JOB NO: DATE: DESIGNED BY: SHEET: 240218 8/16/2022 M.C. PV-7 • P`. OF)146,8 4 JOSEPH J. `�y o BRAVO Gn `o ELECTRICAL ` No. 56193 " 741/1""nr CAUTIONI POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH CLIENT: JOYCE MARIA DISCONNECTS AS SHOWN 107 MERCHANT AVENUE,YARMOUTH,MA 02675 AHJ:TOWN OF YARMOUTH(MA) TESLA GATEWAY UTILITY:EVERSOURCE ENERGY(EASTERN MA) AC DISCONNECT METER:2370440 BATTERY PHONE:(508)498-8864 ■�.. . SYSTEM: ■ SYSTEM SIZE(DC): X =4.800 kW SYSTEM SIZE(AC):3.480 kW @ 240V MODULES:12 X HANWHA OCELL:Q.PEAK ���t. DUO BLK ML-G10+400 ���� IQ7PLUS-72-2-USMICROIN92R [2 02 X ENPHASE �� PEAK1 X29] PEAK OUTPUT:12 295=3,540VA MAX OUTPUT:12 X 290=3,480VA 12 PV MODULES JUNCTION BOX UTILITY METER BACKED UP LOADS PANEL MERCHANT AVENUE REVISIONS 7.WARNING REVISED BY DATE M.C. 8/16/2022 TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL vveediam F O REV E F FREEDOM FOREVER LLC 135 ROBERT TREAT PAINE DR.,TAUNTON, MA 02780 Tel:(800)385-1075 GREG ALBRIGHT NOTES: (JLt 17--- 1. NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON. CONTRACTOR LICENSE: 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: HOME IMPROVEMENT CONTRACTOR 198080; A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. BUSINESS ELECTRICAL CONTRACTOR LICENSE B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. 902-EL-Al;- 11662;CONSTRUCTION SUPERVISOR LICENSE CS-111662;MASTER ELECTRICIAN C. AERIAL FONT. 1136 MR 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED.SIGNAGE CANNOT BE HAND-WRITTEN. SITE PLACARD 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. JOB Na DATE: DESIGNED BY: SHEET: 240218 8/16/2022 M.C. PV-7A 1 -10 11 -20 21 -30 31 -40 41 -50 51 -60 ENPHASE MICROINVERTER CHART 1 2 ■ 3 CLIENT: JOYCE MARIA 107 MERCHANT AVENUE,YARMOUTH,MA 02675 4 AHJ:TOWN OF YARMOUTH(MA) UTILITY:EVERSOURCE ENERGY(EASTERN MA) METER:2370440 PHONE:(508)498-8864 .,,,,,.., 5 SYSTEM: SYSTEM SIZE2(DC):12 X 400=4.800 kW SYSTEM SIZE(AC):3.480 kW @ 240V MODULES:L-X HANWHA OCELL:O.PEAK BLK G10+ 400 DUO US-M-2-US[ 40 MICROINVERTERS:12 X ENPHASE 6 .„„„,., PEAK OUTPUT:TP1 X9] PEAKUPUT: 295= 8 A MAX OUTPUT:12 X 290=3,480VA 7 ■ REVISIONS NO. REVISED BY DATE 8 1 M.C. 8/16/2022 r. V ' dc3 9F OP t V EF FREEDOM FOREVER LLC 135 ROBERT TREAT PAINE DR.,TAUNTON, MA 02780 Tel:(800)385-1075 GREG ALBRIGHT 10 %A1 V / G4\- CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISOR LICENSE CS-111662;MASTER ELECTRICIAN 1136 MR MICROINVERTER CHART JOB NO: DATE: DESIGNED BY: SHEET: 240218 8/16/2022 M.C. PV-8 • SAFETY PLAN MARK UP KEY INSTRUCTIONS: OP PERMANENT ANCHOR 1. USE SYMBOLS IN KEY TO MARK UP THIS SHEET. . O TEMPORARY ANCHOR Sta uf 2. SAFETY PLAN MUST BE MARKED BEFORE JOB STARTS AS PART OF THE PRE-PLAN IL INSTALLER LADDER 3. DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE &MAKE NOTES ON THE JHA SHEET B JUNCTION / COMBINER BOX IN CASE OF EMERGENCY _ S STUB-OUT aawagINJURY HOTLINE -_ XSKYLIGHT (855)400-7233 NO LADDER ACCESS (STEEP NEAREST HOSPITAL OR OCCUPATIONAUINDUSTRIAL CLINIC GRADE OR GROUND LEVEL OBSTRUCTIONS) NAME: CLIENT: JOYCE MARIA 02675ERCHANTAVENUE,YARMOUTH,MA RESTRICTED ACCESS ADDRESS: AHJ:TOWN OF YARMOUTH(MA) UTILITY:EVERSOURCE ENERGY(EASTERN CONDUIT MA) METER:2370440 SAFETY COACH CONTACT INFORMATION PHONE:(508)498-8864 NAME: GAS SHUT OFF SYSTEM: SYSTEM SIZE(DC):12 X 400=4.800 kW PHONE NUMBER: a WATER SHUT OFF SYSTEM SIZE(AC):3.480 kW @240V MODULES:12 X HANWHA QCELL:Q.PEAK DUO BLK ML-G10+400 ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE MICROINVERTERS:12 X ENPHASE SAFETY PLAN AND SIGN INDICATING THAT THEY ARE O SERVICE DROP IQ7PLUS-72-2-US[240V] PEAK OUTPUT:12 X 295=3,540VA AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR MAX OUTPUT:12 X 290=3,480VA WORKING SAFELY. O POWER LINES MERCHANT AVENUE NAME SIGNATURE BREAK AND WATER LOG . REVISIONS NOREVISED BY DATE 1 M.C. 8/16/2022 THIS LOG IS TO BE FILLED OUT ANY TIME THE TEMP EXCEEDS 90 DEGREES.THE CREW LEAD AND ROOF LEAD ARE RESPONSIBLE FOR ENSURING THIS IS - - COMPLETED AND UPLOADED AT THE END OF EVERYDAY WHEN TEMPS EXCEED 90 DEGREES - - NAME 0800HRS 0900HRS 1000HRS 1100HRS 1200HRS 1300HRS 1400HRS 1500HRS 1600HRS , O R , ,;E FREEDOM FOREVER LLC 135 ROBERT TREAT PAINE DR.,TAUNTON, MA 02780 Tel:(800)385-1075 GREG ALBRIGHT CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-Al;CONSTRUCTION SUPERVISOR LICENSE CS-111662;MASTER ELECTRICIAN 1136 MR DATE: TIME: SAFETY PLAN JOB NO: DATE: DESIGNED BY: SHEET: 240218 8/16/2022 M.C. PV-9 JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture Ladder Access • Crew leader responsible for communication with the client: Heat Related Illness Prevention NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE • Ladders must be inspected before each use. • Employees shall have access to potable drinking water that is (add as many as necessary by using additional sheets) • Extension ladders must be set up on a firm and level surface at • Client and public is excluded from work area by barricades(N/A, fresh, pure,and suitably cool.The water shall be located as a 4-to-1 rise to run angle(or 75 degrees)and the top must be Yes, No): close as practicable to the areas where employees are working. Define the Hazard: Method/steps to prevent incident: secured to the structure.Extension style ladders placed on Water shall be supplied in sufficient quantity at the beginning of uneven,loose or slippery surfaces must additionally have the Training and Pre-Job Safety Briefing the work shift to provide at least one quart per employee per base firmly anchored or lashed so the base will not slip out. • All employees onsite shall be made aware of the specific hazards hour for drinking for the entire shift.Employees may begin the • Extension ladders must be used with walk-through devices or of this project and review this HJA during a pre-job briefing,and shift with smaller quantities of water if they identify the location the ladder must extend 36"above the stepping off point. their signature indicates awareness of site conditions and the and have effective means for replenishment during the shift to Define the Hazard: Method/steps to prevent incident: • A-frame ladders must only be climbed with the ladder spreader plan to eliminate any hazards identified prior to and during the allow employees to drink on quart or more per hour.The bars locked in the open position;A-frame ladders shall not be project. frequent drinking of water shall be encouraged. climbed while in the closed position(ex,closed and used while • Shade shall be present when temperature exceeds 80 degrees leaned against a structure). • Crew leader(name/title): Fahrenheit.When the outdoor temperature in the work exceeds Define the Hazard: Method/steps to prevent incident: • Additional notes: 80 degrees Fahrenheit, employees shall have and maintain one • Crew member(name/title): or more areas with shade at all times. Mobile Equipment • New employees must be acclimatized. New employees will be • Only Qualified operators will operate equipment;operators must • Crew member(name/title): monitored by their Crew Leader(site supervisor)for the first two maintain a certification on their person for the equipment being (2)weeks of employment or longer when necessary. Define the Hazard: Method/steps to prevent incident: operated. • Crew member(name/title): • Employees will be allowed and encouraged to implement • Type(s)of mobile equipment(Type/Make/Model): scheduled breaks during each shift.Employees must take • Crew member(name/title): cool-down breaks in the shade any time they feel the need to do • Qualified operator(s): so to protect them from overheating.Supervisors are • Crew member(name/title): REQUIRED to allow employees any break period they need Material Handling and Storage during high heat conditions. CLIENT: JOYCE MARIA • Materials will be staged/stored in a way that does not present a Airborne Contaminants: • Cool Vests are encouraged for all employees at all times during 107 MERCHANT AVENUE,YARMOUTH,MA hazard to client,personnel or public. Materials stored on the • Asbestos-containing(Transite)piping (ACP)-Do not disturb periods of high heat. 02675 roof will be physically protect from failing or sliding off. (move,drill, cut fracture,etc.) • Identify the location of the closet Occupational/Industrial Clinic UTL TOWN R YARMOUTH(NIA) UTILITY:EVERYARMOUTH ENERGY(EASTERN • Asbestos-containing thermal insulation(ACI)and or Hospital in case a crew member becomes ill. MA) Fall Protection Asbestos-containing duct wrapping(ACW)-do not disturb, no METER:2370440 PHONE:(508)498-8864 • A site-specific plan for fall prevention and protection is required attic or crawls ace access is allowed if work to be performed What is the specific plan to provide and replenish sufficient water for prior to starting work and must remain onsite at all times until could cause exposure to personnel,client or public. all employees on site? work is complete;a fall rescue plan must be outlined and • If offsite replenish is necessary,where will you go to replenish discussed among the crew prior to work start. • If yes, list specific tasks and protection in place: water(location/address): SYSTEM: rserson- mustinstalltheir anchor andconnect — SYSTEM SIZE(AC):12X =4.800 kW • First-person-Up U P(FPU) SYSTEM SIZE(AC):3..480 kW @ 240V before any other task, including installing other anchors.The • Who will replenish the drinking water(name): MODULES:12XHANWHAQCELL:Q.PEAK Last-Person-Down(LPD)must be the onlyperson on a roof DUOOIN BLK MRTERS:10 MICROINVERTERS:12 X ENPHASE uninstalling fall protection. IQ7PLUS-72-2-US[240V) • FPCP(name and title): Restroom facilities PEAK OUTPUT:12 X 295=3,540VA MAX OUTPUT:12 X 290=3,480VA • Employees shall have access to restroom facilities with • FPU and LPD(name and title): - hand-washing stations. Use of onsite restroom is at the client's discretion(location is annotated below). If client does not give Electrical Safety permission,location of suitable restroom facilities with • The Electrical Qualified Person(EQP)is required onsite to hand-washing stations offsite will be provided.The onsite perform electrical work. supervisor will identify location and make arrangements to • All electrical work will be performed with equipment in an ensure all employees have access at any point. electrically safe condition(de-energized)unless approval has • Restroom facilities will be(circle one):Onsite-Offsite REVISIONS grantedprior to work. Weather and Environment • If Offsite,add location name and address: Na1REVISED BY DATE been 1 M.C. 8/16/2022 • Service drops and overhead electrical hazards will be indentified • The site supervisor shall forecast the weather conditions at the _ _ and protected from contact,as neccessary. job site, prior to crew arrival, in order to mitigate any hazards Incident Reporting Procedure - - - • EQP(name and tile): associated with inclement weather(heat,cold,wind, rain,etc.) • Contact your Site Supervisor "; • The site supervisor will utilized a portable wind meter Name: • )°. '=c-clam r Public Protection (anemometer)to verify actual onsite wind conditions,by checking F ORE v'J E F • The safety of the Client and Public must be maintained at all at the ground and on any elevated work surface(ex,rooftop) Phone: FREEDOM FOREVER LLC times. prior to work start,at midday and prior to solar panel staging on a 135 ROBERT TREAT PAINE DR.,TAUNTON, The Client and the Public shall beprevented from enteringthe roof. • Contactyour Manager MA)3850 • g Tel:(800)385-1075 work zone through the use of barriers and/or signage,as • Elevated work involving the moving or maneuvering of solar Name: GREG ALBRIGHT required. panels shall cease at 25mph(sustained wind)until wind • Company,Client and Public property shall be protected from subsides. Phone: h.,,,, (i1,A� I , falling objects. • Forecasted weather maximum temp(degrees f): • Pets(including dogs)shall be secured by their owners prior to • Contact your Site Supervisor CONTRACTOR LICENSE: work start. Name: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE • The Client should not leave pets,family members,or others in 902-EL-At;CONSTRUCTION SUPERVISOR charge or care of Employees,Contractors,or Temporary Phone: LICENSE CS-111662;MASTER ELECTRICIAN 1136 MR Workers. With:Your full name, phone number,office location,brief description SAFETY PLAN of what happen and when. JOB NO: DATE: DESIGNED BY: SHEET: 240218 8/16/2022 M.C. PV-10 -- powered by MECHANICAL SPECIFICATION x :, - " Fo .st 74.01 x 41.1 In x 1.261n(Includ;ng frame) (1879mm x 1045mm x 32mm) <ae u93amm y1"Y 1 ` 15.6'(395.5 mm( ,,,,,..,.,., rr .I t - 48.5 bs(220 kg) - - --_ _ . `a aH ' ^'f t I I __-___.�.Y---�_._-__.__._.-_____. 1_ Bt<91'(:15C..•m.) } 0.13in 32mm r 9'(t i ;* xy �� I I 1 Coyt ( )thcrmalypre pro-stressed c� s a s7 ' t anti-ref.ec:ion technology r< S �-.*', Y -w2 5:,. x,,,+, +.3 '`' r r y.t"d` _ __ .',r f`'.,..d "" s-itp 7, R..f tt a .,re�t R4,ar,i 7b s.:ra- r.., �,vL�. Compositefilrn 3sr(sr.s+mr "?{ _ -•5''1'� .aC -a"+.c T`hA'Sr ,1 .�-an.. Si,-- - 44 o a c. i ; '.t,�a,Ev Y.»" �z ,.- . _,,� F(� -- B,ackar:ocized_urrinum -- ----- ku" " "� °'�' -r- -s'` �" � ' ` ('.« i 6 x 22 monocr s,alllne Q.ANTUM solar half cells ® fi• rs �s,. i>.,,i, r°< �., r",,f.,A + t C qs 'L '; 's.F--�_ -.- - _ �'''�f Y d �"t w ..k 'z'a '.. `i "� ` k�V ' ,`;h `�• .--,-.0--,-.7.k.,-.T:,. ...,,- /.fr' _,,..n Box 2.09-3.98in x 1.26-2.36 in x 0.59-0.71'in r.be. <, ) `. ,� r' T^ --" '- a ''S 2f t,r. r- di tsn fe-t 1: _ -------- 53-101inm x 32-60mm x 15-18mm),IP67,with bypass diodes s.1 r-z5omm� < " -"..., s s:=5.c,n ,`s'`s- �. '-.� '; ' .� T'" - ft. 4mm2 Solar Cable,(+)>_49.2in(1250mm),(-)z49.2in(1250mm) ~�`" -..:i •-� ,, S �a `s+7T• p:ffa' fi>s --���a�� mv`x� �t IA • c„,,,,,,, _ Staubli MC4:IP68_ ____� -- -- - 1 r ~-__1..I - ,A ,.: t.rk�b3. ��� 2 E` 1.-1.26'02 m,°i DETAIL.A 063 a6••66 0.06'(1<Smmt I-.L033'(&5mm1 R _\^'1 ELECTRICAL CHARACTERISTICS Q`�P EA K }D U Or<V L K': M L V io� POWER CLASS 385 390 395 400 405 �, ,; ��� /��� _ l FEis( rc"',r;;P;CcAT STANDARD TEST CO -:13i O%S FTC (POv`IER TOLERANCE -0 LV) _-.-- �' (•� -` ` ; r i(,.;eretMPP- Pu„ [W] 385 390 395 400 405 ENDURING HIGH , ' SnortCircuit Current= Ise [A] 1104 11.07 11.10 11.14 11.17 E •s s _._-4YR � ,.,," " U n Cl u VuE,age' Vo.; [V] 45,19 45.23 45.27 45.30 45,34 ORMANCE B s " "'�Q Current ti M P [A] 10.59 loss 10.71 10.77 10 83 • e f �� TOIIIPS ND PV,;. 1 Ft MPP Vo V [V] 3636 3662 36.88 3713 3739 14, r LQ:.J • til. .• c fr(crcv n E/] 219.6 x19.9 >_20.1 >_20.4 >_20.6 sawn Mif:I,J,Urr,PEr.FCrzF AN<;6 AT NOki7l:,L uF-[Fr A I G CONDITIONS.I,'.tOT. 202j"`' roveiiat5122P Pu,: 1W) 288.8 292.6 296.3 300.1 3038 Warranty CELLS ..�,..--_,(..�.,•.:� :- Y`eld++'I'• c Snort C,(c,if Currant Is;; [A' 8.90 8.92 8.95 8.97 9.00 L Open C. pit Solregc Vu„ [V] 42.62 42.65 42.69 42.72 42.76 BREAKING THE 20%EFFICIENCY BARRIER ._ Car rt Fd,FP 1w, [A] 8.35 8.41 8.46 8.51 8.57 nl 4111 Q.ANTUM DUO Z Technology with zero gap cell layout d tt ,e et MFS Mw, [V] 34.59 34.81 35.03 35.25 35 46 "' Measurement tolerances Pe,-,±3%;1,,V+,,;±5%at STC:1000W/m',25±2°C,AM L5 according to IEC 60904-3.1800 W/m1,NMO t,spectrum AM 1.5 boosts module efficiency up to 20.9%. --�_ 0 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY u At least 98 r o'nem: a.power daring On 0 CELLS is the first solar module manufacturer to pass the most comprehen- ee �., .- "°° °' st year rnere&ter max 0.5% sive quality programme in the industry:The new"Quality Controlled PV"of o'r on'rt op per year.Al;eas;93 At U,a9 L L �J? o nomnal power up to 10 years At 5 //- the independent certification institute TUV Rheinland. _ � east 86%of nominal power up to .a. 25 years. = ea--r r z INNOVATIVE ALL-WEATHER TECHNOLOGY AG .< . " - A care wt"inrneasurementtcleraoc- a : ♦ e6 es F.;!I waramies in accorcance with w �: Optimal yields,whatever the weather with excellent ZOO eaa 000 800 1000 tnewarr my terms of the C CELLS ( tik( r( ,; low-light and temperature behavior. 40 saes organ':sation or your respect vs o Ii).I I( ' - ° is country. ':, , :.• a ( - vcxus Typical module performance under low irradiance conditions in tt iff , t (r. _ ENDURING HIGH PERFORMANCE ' ' " '-, comparison to STC conditions(25°c,1000W/m'( a1t}1` I', I` „' ,� / Long-term yield security with Anti LID Technology,Anti PID TEMPERATURE COEFFICIENTS T - - o t +' Technology',Hot-Spot Protect and Traceable Quality Tra.QT^ - - - v .'liTemper a..uruCo..fr(ae.n"ofl,,: a [%/K] +0.04 TernperatureCocffl"an"o1V.._ R [%/K] -0.27 I Y a 7e( pet atein Coefficient of R,;.° y [%/K] -0.34 Nor-renal Moule Operating Ti irpereture NMOT [°F] 109±5.4(43+3°C) m ( EXTREME WEATHER RATING 0 45, High-tech aluminum alloy frame,certified for PROPERTIES FOR SYSTEM DESIGN , ,1 high snow(5400 Pa)and wind loads(4000 Pa). Maximum System t< ltegc V-,..., [V] 1000(IEC)/1000(UL) PV<r cdu c s,_r nClass II c iht MP, urnSeries Fu R.-tin. [ADC] 20 Pito k,❑ t sedorANSI/UL61730 TYPE 2 w A RELIABLE INVESTMENT e� M°x Design Lo.d,Push/Pe11- [,bs/ft'] 75(3600 Pa)/55(2660Pa) pct^ttedMocoeTanperatuie -40°F up to+185°F D l Ag7 Inclusive 25-year product warranty and 25-year on Cc"tinucus Duty 1-40°C up to+85°C) ]. bs/ft'] 113(5400 Pa)/84(4000Pa) linear performance warranty. Max.M<^x Te,:Load,PushjPull' ,,see instal'.ation Manual 6 BUSBAR 12 BUSEAR -APT test conditions according to IEC/TS 62804-1.2015,method A(-1500V,96h) QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION CELL TECHNOLOGY CELL TECHNOLOGY See data sheet on rear for further information. p. UL 61736 CE Com 53' Ora ty Co oiled PV VRheiniand, w ! Ib [O_01 4o'Hcl O IEC 6215 6,!C51730 2316, L THE IDEAL SOLUTION FOR• us Phe 10 9.69 2 6 soarcer:sI S�® Horizonte!- 76.4in 43.3 in 48.o,n 16561bs 24 24 32 ecavc ..ao go^:g. cc ,:e,US m Packaging 1940mm 1100 mm 1220mm 751kg pallets pallets modules Rooftop oe arrays on of e.,3c .D "'"' res aortal bulld:rgs Note:installation instructions must be followed,See the irsta'.letlon and operating manual or contact our technical service department for further information on approved installation and use of this product. CCELS. Hanwha 0 CELLS America Inc. Engineered in Germany 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1949 748 59 96 1 EMAIL ina,uiry@us q-ceils.com I WEB www q-cells us `L,I, ,yi Enphase IQ 7 and IQ 7+ Microinverters Enphase C.1 croiri crtcrs INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell/120 half-cell PV modules 60-ce1l/120 half-cell and 72- only cell/144 half-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V-37 V 27 V-4 5 V Operating range 16 V-48 V 16 V-60 V . Min/Max start voltage 22 V/48 V 22 V/60 V r--s-y i. .-a The high-powered smart grid-ready Max DC short circuit current(module Isc) 15 A 15 A izi i s. e Overvoltage class DC port II 11 Enphase IQ 7 Micro'"" and Enphase IQ 7+ rvlicror" DC port backfeed current 0 A 0 A 1C17 arid 10 "B' dramatically simplify the installation process while PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; A. AC side protection requires max 20A per branch circuit iv •croinveriersachieving the highest system efficiency. OUTPUT DATA(Ac) IQ 7 Microinverter IQ 7+Microinverter Part of the Enphase IQ System,the IQ 7 and Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA IQ 7+ Microinverters integrate with the Enphase Nominal(L-L)voltage/range' 240 V/ 208 V/ 240 V/ 208 V/ IQ Envoy'", Enphase IQ Battery'',and the Enphase 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Enlighten'" monitoring and analysis software. Nominal frequency 60 Hz 60 Hz IQ Series Microinverters extend the reliability Extended frequency range 47 68 Hz 47 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms standards set forth by previous generations and Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) undergo over a million hours of power-on testing, Overvoltage class AC port III III AC port backfeed current 18 mA 18 mA enabling Enphase to provide an industry-leading Power factor setting 1.0 1.0 warranty of up to 25 years. Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6°% 97.6 i. 97.5 97.3 CEC weighted efficiency 97.0% 97.0 97.0% 97.0 MECHANICAL DATA Ambient temperature range -40°C to+65°C Easy to Install Relative humidity range 4%to 100%(condensing) Connector type MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) I '"' • Lightweight and simple Dimensions(HxWxD) 212 mm x 175 mm x 30.2 mm(without bracket) • Faster installation with improved,lighter two-wire cabling Weight 1.08 kg(2.38 lbs) ,-- _ --- • Built-in rapid shutdown compliant(NEC 2014&2017) Cooling Natural convection-No fans - r� 'ig Approved for wet locations Yes Pollution degree PD3 jam, Productive and Reliable Enclosure Class II double-insulated,corrosion resistant polymeric enclosure -- -� • Optimized for high powered 60-cell/120 half-cell and 72 Environmental category'UV exposure rating NEMA Type 6/outdoor .(DI • , ii' cell/144 half-cell*modules FEATURES I '� More than a million hours of testing Communication Power Line Communication(PLC) \ 'N - - • Class 11 double-insulated enclosure Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. eENPHASE ir. 7I® • UL listed Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break IQ 7.... disconnect required by NEC 690. -"All, _ IfL 0l.�. Compliance CA Rule 21 (UL 1741-SA) Smart Grid Ready UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, ' � J4.,,,,,: „.16,,, ,, .__ tt,F CAN/CSA-C22.2 NO.107.1-01 ® � '' • Com lies with advanced rid su ort,volta e and P 9 PP 9 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC ' frequency ride-through requirements 2017,and NEC 2020 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, • Remotely updates to respond to changing for AC and DC conductors,when installed according manufacturer's instructions. grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) 1.No enforced DC/AC ratio.See the compatibility calculator at https://enehase.com/en-us/support/module-compatibility. 0The IQ 7+Micro is required to support 72-cell/144 half-cell modules. 2.Nominal voltage range can he extended beyond nominal if required by the utility. CERTIFIED 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. WITV EN P H AS E To learn more about Enphase offerings,visit enphase.com EN P HAS E. To learn more about Enphase offerings,visit enphase.com 2u10 Elfiphadc Er<lrii SII riohf,_rcf,;,r,od Enpl'o 7,o,u_E :has Ic_lo,En, u,.,IQ 7,E ,-a,e Ie L f),,sc IQ E d,Lery, FirphdsQ F r I.T.:,,x,Fiulid,dciQEn.cy6Hc.%rtracr uks b,so..,c,I,r Iws Q:c t=ctC .Ir e.c) *af,c,Fr id/.Lc. tic.._..;uIJ,, ,toJ,,u ._,vC-i) . . • POWERWALL POWERWALL Backup Gatev,ay 2 Ti . Eacl,:dp GC.Vva 3 2 l'or Tr2sf, l2c);,-;\er.,:::p,oedes c:herci i rnaejc,ctrncnt T Tesla Powerwall is a fully-integrated AC battery system for residential or light commercial use. Its rechargeable lithium-ion T ...,_, i,..., i._ . ,t-lnd mon:Cri;Y;4 fOr SO:3!"seh-cormttdhrtption. hrti,e-0 .t..yci oc.et,ol.L,e,d backnp. The EL,,,c.ltult):-:.e.ten't,:,2 con,'h,l,t cnnnneth-)e to the qnd,tt,rito.-r,t11.tte.11y battery pack provides energy storage for solar self-consumption, ii--it-i-ichni:i ci,it-ii-,iyii.-3,ii,i--q-, cirovi-- D iii ii.ei-,m:iiii-li;tri-iris-t!ii-ri tohdchnit.nc7ver. time-based control,and backup. ii,ii-14,,,n eca,.;:e,:;ecj con a cc in cl(cult 12,rea'.<er. tl:e B3ctlx6p C5t.,te0dy 2 ct.-.,n,tit, Lht,f,td:-.2(... et thc se10100trenc(-:.V,liten the o0ftdh:-.11 intend!fttenelltte,tird's Powerwall's electrical interface provides a simple connection to in,ti.ilcd,tn,,t,Packt.„tt,Gate,:tic,y 2 odn alt.()runctinn,..,d to center. any home or building. Its revolutionary compact design achieves i Ise EltJcittip Cdtewdy 2 cornetikinlot;tes direct \lin Cowerwdll,;:llo,i,eng tied market-leading energy density and is easy to install,enabling to monitor erl,,,rgy ds,.?dnd rnattlt.:,,e lt..,,dok..0 energy te,erves from E:r,'y rhoe!le owners to quickly realize the benefits of reliable,clean power. CieVk:le With tt.e lo-- PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS AC Voltage(Nominal) 1/i,//,:')\' Dimensions PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS Feed-In Type Weight AC Voltage(Nominal) DimensionsGrid Frequency Mounting options Feed-In Type Current Rating z , (1. Weight l'zi I,, '2- .L; Grid Frequency ,,La Maximum Input Short Circuit Current Mounting options Total Energy Overcurrent Protection Device I Usable Energy I Z C'i,i,R; Overvoltage Category 753 err' 147 row Real Power,max continuous (255 In) (5751n) AC Meter ' Real Power,peak(10s,off-grid/backup) 11 i0'. (. ,..(i, .:1, g:l:,2,i - H Primary Connectivity TESLiro lify,l' Apparent Power,max continuous 1.11."-7,1 Secondary Connectivity (.1.(0',i,,i, ,'(.'r I I- i, lei Apparent Power,peak(10s,off-grid/backup) I:2 I RA r(r•,,r'.- ,r,.,5(1-LL'L,r,.;L:. T -1-4 n L Fl Illll User Interface VI! Maximum Supply Fault Current 10 k,.% iIIIIIH Operating Modes 1-,R.R.iwi Rii r-,,I r r.,,,J r r...,r(Art,hm,. 660 .r Maximum Output Fault Current 01111 IIII01 .11IIIIIII1 1'150 rrrn Backup Transition `,,iii,,,-1,...(1,-.: r i,t '' r-,,:l';•'', Overcurrent Protection Device I 1I2 II (45.3 la) Imbalance for Split-Phase Loads 1127.1,, 111I0I Modularity 11:IIIT Power Factor Output Range 1 IIIII 1 1IIIII: Optional Internal Panelboard I Power Factor Range(full-rated power) I 1III IIIIIIII' Internal Battery DC Voltage i) : c ,icRi Warranty Round Trip Efficiency' - - Warranty ENVIRONMENTAL SPECIFICATIONS -- --1 411 ---- 149 Operating Temperature Recommended Temperature 0'C I R:RC,',0 t::12• y;L;,LL'LL; Operating Humidity(RH) COMPLIANCE INFORMATION Storage Conditions Certifications OR: , ...:, ,,ir I.r.nl-r/,r-Jrt...;li, COMPLIANCE INFORMATION ENVIRONMENTAL SPECIFICATIONS I , 1,1: ;1\ '''',...: ',' ',',,,, I.,,'r,,' (-0E.-",- Certifications 1,1i ii11 I,I 'ir,...1A,lil ,)1(:, JI 1101 PC', Operating Temperature :':(, k, )r•'...v 1F to Grid Connection Wig ici,,'.(1,2 COrl'I',.;.-.1'.,,,,11',.' Maximum Elevation -,C,,,n ;'-) .-., t.) Operating Humidity(RH) r Ri 1i!,,', ((ii gi: (-..i..) Emissions ' Ci. ,'„ t.', ...1,..0., k, - 1.,(.1CO3 Environment Emissions I,i i R.,n. Maximum Elevation Environmental Enclosure Type I.(I1A 7,t, Seismic /,',',, ILL_ i,14', 21)(1. 'I r(,I., Ingress Rating Environment Enclosure Type \:Mi. Wet Location Rating Noise Level a im ©2016 Eaton.All rights reserved. pe.eaton.corn ilY Eaton general duty non-fusible safety switch DG221 URB UPC:782113120232 Dimensions: • Height: 10.81 IN • Length: 6.88 IN • Width: 6.38 IN Weight:6 LB Notes:WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Warranties: • Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: • Type: Non-fusible, single-throw • Amperage Rating: 30A • Enclosure: NEMA 3R, Rainproof • Enclosure Material: Painted galvanized steel • Fuse Configuration: Non-fusible • Number Of Poles: Two-pole • Number Of Wires: Two-wire • Product Category: General duty safety switch • Voltage Rating: 240V Supporting documents: • Eatons Volume 2-Commercial Distribution • Eaton Specification Sheet- DG221URB Certifications: • UL Listed Product compliance: No Data F M I LBAN K* CI 0 ENERGY AT WORK #i f !]j f f ' ,::::1':' f - U5929-XL-INS x ` 1 • (- -Y_IFEATURE TABLE • ITEM OTY DESCRIPTION A 6 U/L MNTG.EMBOSS r B 3 '''A,1.1Y..1%CONC.K.O. r C 1 '%.1.,'/,.1Y,2 CONC.K.O. ', D 1 SOLID K.O. t j E 2 'AY.1,17.CONC.K.O. Catalog Number U5929-XL-INS Jaw Quantity 4 Terminal Marketing Product Description 4 Terminal Ring Type Small Bypass Type No Bypass Closing Plate Insulated Barrier Number of Meter Positions 1 Position - ��I o UPC 784572629288 1 g1,.°) �-..°`''' �I V cam" Equipment Ground Ground Bar i `,, _ i f, va\itO 0 Length(IN) 3.313 1:. gv 4,11;1A1,-. , Hub Opening Small Closing Plate =• I '' '�!f Width(IN) 8 g ,,,n" dilf ,tom 1 Line Side Wire Range 12- 1/0 AWG { I .�/ �, . Height(IN) 11.5 it,,, " B c 'r� Load Side Wire Range 12-1/0 AWG f p I s Brand Name Milbank CodQ, Number Of Receptacles 0 - I ® ) ® t...,--,--,-,. ., miwwwwwwomiEl. L Type Ring Type Meter Socket Application Meter Socket 6'O.D. 35/16"LD. --• j Standard UL Listed;Type 3R Voltage Rating 600 Volts Alternating Current c 0 E Amperage Rating 100 Continuous Ampere Phase 1 Phase —� r `� O� o i) Frequency Rating 60 Hertz 1 yfi' " fit- MILBANK' 111. 111111111111111•11=111 Size 3.313E x 8W x 11.5H IIM_ ~ 13/16„ ENERGY AT WORK 2 5116" 2 5/16' f.- ....r�__.__...e-.......-,.. '....,,_.,....�® All dimensions are+/-1/16". Number Of Cutouts 0 Drawing views are not to scale. Cutout Size No Main Breaker version: Peaae"°naultservngufllY(°r h , r - d ec rybY pI Y d Cable Entry Overhead or Underground All I ° t b taped by I sed I °and ow w.r II t naland I I s,la d g'ti°n Mb k reserves the right t°make changes in Terminal Single Mechanical Insulation Glass Polyester Mounting Surface Mount Enclosure G90 Galvanized Steel with Powder Coat Finish Please consult serving utility for their requirements prior to ordering or installing,as specifications and approvals vary by utility and may require local electrical inspector approval.All installations must be installed by a licensed electrician and must comply with all national and local codes,laws and regulations.M.Ibank reserves the right to make changes in specifications and features shown without notice or obligation. t,,, ,. .'�T,' t .,Fr,.f 4T,:: i �•?'j'1 .1° �?; >tr• r'`%a ,;."a yi ,. l'. _ ,, ,• : ,...,, ,. ,: . ... �``��.//{� ;. ROCKIT �� For Installers. By Installers. ' � � `� ,, •� fl�' Asa '''''s'lc:;:;:''''.: 4'.::1'''''';'::14:'''''''-'17. '''' C0L DLII 9 The fast installing Rocklt Coupling � ' - � �) .._.nom-.,' . r�•` ' easily attaches to the module frame � �'*�- x, to bridge the gaps between modules. l'll '° • -h' a � F.. n 4 ,fir SKIRT---'----- - '---- ' '-'----- -----(-: '"":77L--.7-7--,..._:_.......,_:.,„..4.4 4» .w . The sleek black Skirt installs first and acts as an alignment guide for the entire array. The Skirt End Cap does double duty as a skirt coupling device and an aesthetically- ''"' - pleasing finishing touch. may--- ;, --, R C I T Ci 0 Vit!T � p ��� a Featuring integrated bonding pins, the Rocklt wY ,J Mount connects to the Slide and can easily be ., .. F " ) positioned for fast installation. Features RaCKI1 7f � down leveling. Yom. �m ili,'--- ---l. i''' a ll--,4 COMPLETE RAIL-LESS RACKING SYSTEM „.1 ;e""r , «. The Rocklt system is the industry's premier rail less K,}` I t`1 PV racking system for composition shingle, tile, and i., ,, metal roofs. Designed in conjunction with the needs of „ Composition Shingle, installers, Rocklt quickly & easily installs with a single tool. o■ Tile,Metas , ; ,z: Featuring an easy-to-position alignment slide and a top - " down levelingRocklt },, system, is logistically intelligent with � � � no need to ship or transport long rails. Components are a®�� °' ' ' t Dov® Rail-Less , available in a black finish that complements both commercial �� and residential applications. Conforms to UL 2703. C .2:!-.'ill:-.,:..E c. Cra ✓rla i L I '1';':: Structural-Attach • Patented watertight technology Direct-Attach ._, • Fully integrated bonding ' '"`_ • Top-down leveling system [ E C K I- S L ( 1 • North-South adjustability A .5,,,,,,--,,'t Available in three variations, the Rocklt `- • Single tool installs " '7 -- „ Slide allows installation on composition shingle, tile, and metal roofs. '� STREAMLINED INSTALLATION WITH <� ' 25 YEAR 4tiARRul)Tv R M = ��l I E iv! N T MINIMAL ROOF PENETRATIONS Attaches and fully bonds P.1LPE's (Module fji Level Power Electronics)to the module frame with a single bolt clip. V ��/�����/�����/���/����������/���/ ECOFASTENSOLAR COM ,i structural ENGINEERS July 5,2022 EcoFasten Solar LLC 4141 W Van Buren St,Ste 2 Phoenix,AZ 85009 TEL:(877)859-3947 Attn.: Eco Fasten Solar LLC-Engineering Department Re:Report#2015-05884HG.07.01—EcoFasten-Rocklt System for Gable and Hip Roofs Subject: Engineering Certification for the State of Massachusetts PZSE,Inc.—Structural Engineers has provided engineering and span tables for the EcoFasten-Rocklt System,as presented in PZSE Report#2015-05884HG.07.01,"Engineering Certification for the EcoFasten-Rocklt System for Gable and Hip Roofs". All information,data,and analysis therein are based on,and comply with,the following building codes and typical specifications: Building Codes: 1. ASCE/SEI 7-10&7-16 Minimum Design Loads for Buildings and Other Structures,by American Society of Civil Engineers 2. 2012, 2015,&2018 International Building Code 3. 2012,2015,&2018 International Residential Code 4. AC428,Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels,November 1,2012 by ICC-ES 5. Aluminum Design Manual 2010&2018, by The Aluminum Association, Inc. 6. ANSI/AWC NDS-2015&2018,National Design Specification for Wood Construction, by the American Wood Council Design Criteria: Risk Category II Seismic Design Category=A-E Exposure Category=B, C& D Basic Wind Speed(ultimate)per ASCE 7-16=90 mph to 180 mph Ground Snow Load=0 to 60(psf) DIGITALLY SEALED This letter certifies that the loading criteria and design basis for the (H OFlbiq 6, 6 y EcoFasten-Rocklt System Span Tables are ; „'A PAUL K. in compliance with the above codes. ZACHER TRUCTURAL B„ y10 If you have any questions on the above,do not hesitate to call. hoc oisTECk°��a`��' 'SS/ONAIENG Prepared by: PZSE,Inc.—Structural Engineers Roseville,CA 1478 Stone Point Drive,Suite 190, Roseville, CA 95661 916.961.3960 916.961.3965 www.pzse.com