Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLDE-23-000297 (2)
CODE INFORMATION w o L,_,_ SOLAR INDIVIDUAL PERMIT PACKAGE APPLICABLE CODES, LAWS AND REGULATIONS °' o MA STATE BUILDING CODE,9TH ED, BASE VOLUME O z 3 a MA STATE BUILDING CODE,9TH ED, RESIDENTIAL VOLUME - 0 o 'p " CL z -.EXISTING BUILDING CODE OF MASSACHUSETTS a . o o MECHANICAL CODE 2015 OF MASSACHUSETTS " a a 2020 MASSACHUSETTS FIRE CODE 0- = u D E N N I S PAGE ENERGY CONSERVATION CODE 2015 OF MASSACHUSETTS p, ENERGY CONSERVATION CODE 2018 OF MASSACHUSETTS 5 . 88 kW GRID TIED PHOTOVOLTAIC SYSTEM SATELLITE IMAGE 5089189409 PROJECT LOCATION -,,i , , ?PIN '''..74-' , , 52 CAPT- BLOUNT RD Y. w� F Y •Y; S YARMOUTH , � ✓h � 75t4,4 �b MASSACHUSETTS 02664 * � : V „”' : -"; . .:I ' -,%'," . ,::': ' �` AHJ : YARMOUTH TOWN ~ ' 4 dr-' UTILITY: EVERSOURCE ENERGY (FORMERLY NSTAR ELECTRIC COMPANY) j ` . _ .. 4 e W JOB NOTES SHEET INDEX w SCOPE OF WORK PV SOLAR ARCHITECTURAL DRAWINGS N a to Y - (N) 5.880 kW PHOTOVOLTAIC SYSTEM PVA-0 COVER SHEET a v, Q - (14) 420W (Model SPR-A-420-G-AC) PV MODULES PVA-1 4 ARRAY LAYOUT w I- 0 o_ - POINT OF INTERCONNECTION AT MAIN SERVICE PANEL WITH CIRCUIT BREAKER 0 I- D> I- z w a O 0 Q wa r J '-'-' a m � Q IY Z a Z o > W F U = j O� .�- o 7 . C) (NI- z PV SOLAR STRUCTURAL DRAWINGS c PVS-1 ' MOUNTING DETAILS - >- 0 oo to co Lri REVISIONS REV DESCRIPTION DATE DB PV SOLAR ELECTRICAL DRAWINGS PVE-1 ELECTRICAL SINGLE-LINE DIAGRAM& SPECIFICATIONS DRAWN BY: PVE-2 ELECTRICAL CALCULATION ROVILYN CARTA PVE-3 ELECTRICAL DATA&SPECIFICATIONS INSTALLER SOLAR WOLF ENERGY PVE-4 EQUINOX GROUNDING DETAILS PROJECT RP-186053 PVE-5 BRANCH DIAGRAM DATE DRAWN 12-05-2021 SCALE NTS SHEET PVA-0 o Ce ~ VI S z LLJ W o 0 TABLE 1 -ARRAYS INFORMATION US r_ r_ 4MAX. ROOF ROOFING ATTACHMENT NO. OF FRAMING RAFTER PENETRATION MAX. ATTACHMENT MAX. RAIL 0 o o N PITCH TYPE TYPE STORIES TYPE (in.) SPAN (ft.) PATTERN (in.) SPACING (in.) OVERHANG (in.) m Z < < oo Zc' a f ROOF 1 30° Comp Shingle Pegasus L-foot 1 2x4 Truss @ 24" OC 6' Staggered 48" 16" ° _ i -- pce O -" .. o -- -- -- -- -- -- -- -- -- u -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- oH OF -- -- -- -- -- -- -- -- -- -- PAYMON N -- -- c ESKANDANIAN c' STRUCTURAL to CHECK TABLE 2 FOR PENETRATION PATTERN GUIDE ,o No.51866 Q tA' '%/STE*) FIG 1: ROOF 1 STRUCTURAL FRAMING DETAIL FIGURE 2: INVISIMOUNT WITH PEGASUS SOLAR ROOF ATTACHMENT DETAILS @ TRUSS/ RAFTERS 11 INVISIMOUNT RAIL L FOOT .w'1. PV MODULE '� PV MODULE 1�.. Digitally signed by Paymon "0..0Eskandanian BASE FLASHING Date:2021.12.06 ' 11:24:27-08'00' PV MODULE 'iel �! ( 0 - L FOOT) ' , 1 ELEVAT D CONE WITH TILE POST ASSEMBLY /� .........1 /ISLED (E)WOOD SHEATHING 4ff BASE FLASHING \ \\ \ . \�\: W::��\ \ \ \ \ \ \\"\\ \1i' w (~n ID LU C9 BEARING WALL (n N Q BEARING WALL z_ u p y Z (2)5/16"LG.S.S.LAG BOLT WITH (n L1 O(n 5/16"WASHER @ CENTER TYP. < 1J-1 PRE-DRILL REQUIRED. J LU n III Q 0.75"MIN. < O Z = 1 tu Q FIGURE 3: MOUNTING CLAMP a o o Q a z z TABLE 2: PENETRATION GUIDE FOR INSTALL v7 = POSITIONING DETAILS a m Q Q�P TWO OR MORE ROWS OF MODULES Z � Q Z O_K O= 2" 11.8" 11.8" 2" LIJ � U = > 0 _ _ _ ,L4._ __-,,--,L- ��.� %//O//////% Dig O La Z ce Z 4.I L+ I 111 1 � 1 11 '� 11 I I TI , 1- Intru , <�1 1 I 1 1 I I 1 1 I I t I I Q g I 1 II I 1I I I I 1 I I I I I I I i1 L 1: 1 1 ...-41-=i4,----4.-`_1._`1_oJ !t.1._01__l._�_�1_,J Lp.�l.¢J j• 1 ,Y,"1 I. w 1 } 0 1•-i-�f--T•-I'-•I-oi f*'1.' I-�T--&-11-4i 1 ji -1---4-.771 n I 1 '.I 1 1 I 1 I I I I I I I I I 1 1I 1 I F ,..r, 1 1 I I I I I I , I '.I 1 1 I 1 I 1 I 1 I 11.1[1.1.1._ 00 - 1 I I 1 1 1 I I ''1 1 , 1 I I 1 1 -i'-'-r-:-----1. I 1 1 REVISIONS L r---'t" - =ZO -i-;' Lt- -Z-T-T- Z'' ®' L_ ='PT' V REV DESCRIPTION DATE DB STACKED STAGGERED FULLY STAGGERED : jelM. it millan O ONE ROW OF MODULES In . s N DRAWN BY: - _ 1 -�(_1: L __ ._ T-! J l ROVILYN CARTA I I I 1 1 -I I I.O i-of--T 1 _' .„,����`I 1 '.1 1 1 I I 1 1 111 1 1: 11 ii 1 A ////////////A 0 , INSTALLER SOLAR WOLF ENERGY 1 1 1 1 I 1 1 1 -:1 1 1 ! ”.-.1.4.,-.1.4.,4."•• -. I� I . 1 1 1' 1 1 1 I1 1 1 1( V PROJECT RP-186053 `1--"1-t t- `-J - IL -'-7:,----i �-`r-Y=fij 66 CELL MODULE � DATE DRAWN 12-05-2021 FULLY STAGGERED STACKED/STAGGERED •RAILS SHALL BE POSITIONED IN THE NON-CROSS SCALE NTS HATCHED REGIONS SHEET "CHECK TABLE 1 FOR MAX..PENETRATION SPACING AND PENETRATION PATTERN FOR EACH ARRAY. PVS-1 1 g o < 0 0 0 # j- m@@ = 0 E « < C 2 m ° m z z = ` p K I >< z ® E ° § c 0 \ / C C § \� § In ƒ /_ c / \ > > 0 x 0 0 \ \ > e \ § \ 0 * § rn m o m c 0 o o > 0 7 I- _,0 k m § { { § / 0 f § r v § j o , § R S > m g e E m m > _ 0 w m m o_ = m = z K m § ƒ 0 o w -1 § � � 7) @ o m � {m g§ } § § § � k mk § x \\ o m 3zn > rJ F -10 o m > cn 11 0 o a m -1§ \ § « m 0 0 "0 CD \ \ \ ® § t / - P \ § 0 2 > % e M t o > > k@ 6 6 > > < I- m j 2 < ), z o o kxr 1- % m m > o § / E § ) e m m z z = ` P (_ z / w K 0 r CO ) k / E \ ) § $ $ m c / 0 § > \ \ o o R " a § ( § E q = / / q 0 § § 0 2 \ \ \ F. j \ \ \ 2 / 2 § o C 0 -i < o « § -0 ¥ 0 m m m 2 0 m a x a , o c § > m = o c > m m > 0 - 0 ƒ o / \ § c 2 § § % c o = , 2 0 m o 4 � q > 0 m w t > o m c„, ° . z n m o c = \ } \ \ \ 0 x cl m ) m ) cri 2 m 0 I G 2 I j m \ l- \ 0 x \, k < 0 § ) I \ \ 55 o z 0 § § § m g m m >o 0 0 13 § _ G / Z § § l § A § g P I N.) CO $ G 0 4t § > % a a o o > ), = 2 8 6 8 > > < w o , 'a f P@ R N § G § $ e • _ •W 0 § g P i 0 § 0 3 = > $ M 0 0 > > _ » 6 0 6 > > < w 0 / § 2 ( 2 ] DENNIS PAGE - 7 B ( - am GRID-TIED PHOTOVOLTAIC SYSTEM S U N P O VV E R 75 0-0 }\ / & 5< 52 c a�u� CORPORATION, SYSTEMS in 1414 HARBOUR WAY SOUTH ! \ §/ / R.c.,oND, CA 94804 § ; ' (510) 540-0550 § §SomRmm2DUA��R�c�GE [ 1 . \ ELECTRICAL CALCULATION Ce n LLJ W p N v o r r a, '^ ^ Q , 0 z `` u ' 0 a ^ O •O ,n CL Hm Z Z Q c, p o a' Q p = = in D a - 0 - O . SunPower lnvisiMountt'� with R2R Grounding Clip p " Ground Path and Compliance g , RIR Clip + Modul. r '� u,.1 ct.R�p Is Gummi Lu C ww 4 6 CAUTION . Ind Cl.mp 1 'F, , 37 ■ M4m � o z; • � ` Splua+Screw POWER TO THIS BUILDING IS ALSO Ground .. l- 2 jint • Path __ �"" 8 SUPPLIED FROM THE FOLLOWING / cround ' °�� - SOURCES WITH DISCONNECT(S) Lott , Idu.Rs J. . I J` .1 e :�;k,` 1 ; "" ` LOCATED AS SHOWN . Off .-._ gr- -- At ICompliance Bonding Components NEC ' uL PHOTOVOLTAIC Sulking ARRAY ON ROOF �� a Grounding Electrode to 690.47(A) Na (cm Service Panel 690.47(D) SOLAR LOAD w Service Panel to 2 690.43(C) 1741 CENTER �� v Ground Wiro �: LLJ N Ground Wire to SERVICE POINT & 11111i U 03 Ground Lug to 690.43(C) 2703 � _, 0aUTILITY METERING � w o W 1— Rail � > 1— cn Module Frame to . _ < Z = W 4 Module Frame 690.43(C) 2703 UTILITY METER V - �_ 0 ° CL 5 Module Frame n/a 1703 AC z o ._ z 1L a 0 . U ±- 0 >. Raiff to 690.43(A) DISCONNECT Ln o 0 6 Mid Clamp to 690.43(C) 2703 Module Frame 690.43(D) PV METER 0 z a Module Frame to 690.43(A) 52 CA PT-B LO U NT RD } o 7 End Clamp to 690.43(C) 2703 `� Rail 690.43(D) _ REVISIONS 690.43(A) REV DESCRIPTION DATE DB ;', Rail to Splice 690.43(C) 2703 690.43(D) Wnnlirt+',X6ittURrvt1 15 St.ridv.rPkTriM.rj DRAWN BY: ROVILYN CARTA INSTALLER SOLAR WOLF ENERGY PROJECT RP-186053 DATE DRAWN 12-05-2021 FIGURE 1: SUNPOWER EQUINOX GROUNDING DETAILS FIGURE 2: PLACARD IDENTIFYING LOCATION OF DISCONNECTS AND POWER SOURCES SCALE NTS SHEET PVE-4 A-Series:A420 I A415 A410 I A400 A390 SunPower°Residential AC Module SUN PWE R® � ,,t . , ....., , .. . , 0 ` 4er, Inverter Model:Type G/SPWR-A4(IQ 7A5) @240 VAC Peak Output Power 366 VA 420-390 W Residential AC Module Max.Cont.nuous Output Power 349 VA Nom.(L-L)Voltage/Range'(V) 240/211-264 F I � - Sunpbwer®Mc�X2OCl®TeC�1C1OIO�/ Max.Continuous Output Current(A) 1.45 LillI. Built specifically for use with the SunPower Equinox)°'system,the only fully Max.Units per 20A(L-L)Branch Circu;t' 11 -1-- integrated solution designed,engineered,and warranted by one manufacturer. CEC Weighted Efficiency 97.0% i Nom Frequency 60 Hz • .--•-- Highest Power Density Available. Extended Frequency Range 47-68 Hz AC Short Circuit Fault Current Over 3 Cycles 5.8 A rms 1 I ! SunPower's new Maxeon°Gen 5 cell is 65%larger than -- • • Overvoltage Class AC Port III 1 prior generations,delivering the most powerful cell and AC Port Backfeed Current 18 mA - -ii----'-'- highest-efficiency module in residential solar.The result is I , j Power Factor Setting 1.0 r- __;___•--•- more power per square meter than any commercially available solar. Power Factor(adjustable) 0.7 lead./ 0.7 lag. -- - _ - : - . • - I cal;_ ' a.7i'10 . - I I1fit f"'1,e litir47.4*(11 js.10(ifig/,=,li(,1$4oItlji trttC: - _� _ __.♦ Clio 4 A420-G-AC A415-G-AC A410-G-AC A400-G-AC A390-G-AC •25 year limited power warranty �•_- � Warranties ©sERIEs - Nom.Powers(Pnom)W 420 415 410 400 390 •25-year limited product warranty •UL 1703 __ ---- - •- . } ,r "F • Power To). S/ 0% •UL 1741/IEEE-1547 T Module Efficiency 22,5 22.3 22.0 21.5 20.9 Certifications .UL 1741 AC Module(Type 2 fire rated) ? Temp.Coef.(Power) 0.2994/°C and •UL 62109-1/IEC 62109-2 0 P E ~6j�0 Compliance E FCC Part 15 Class B E � E Shade Tol. Integrated module-level max.power point tracking N •ICES-0003 Class B Lr) LO larger,. CAN/CSA-C22.2 NO.107.1-01 FundamentallyDifferent. r- •CA21 L1741 A Rule U S And Better. i / Operating Temp. -40°F to+185°F(-40°C to+85°C) (includes Volt/Var and Reactive Power Priority) fff Max.Ambient Temp. 122°F(50°C) •UL Listed PV Rapid Shutdown Equipment`' Max.Test Load' Wind:125 psf,6000 Pa,611 kg/m,back Enables installation in accordance with: Snow:187 psf,9000 Pa,917 kg/m,front •NEC 690.6(AC module) Highest Lifetime Energy and Savings. Wind:75 psf,3600 Pa,367 kg/m,back •NEC 690.12 Rapid Shutdown(inside and outside the array) Design Load P Y $ - d Snow:125 psf,6000 Pa,611 kg/m,front •NEC 690.15 AC Connectors,690.33(A)-(E)(1) �,r r' [4.12] Designed to deliver 60%more energy over 25 years in ,iiir t/`1, C k ‘q Impact Resistance 1 inch(25 mm)diameter hail at 52 mph(23 m/s) `'p . ' ° " \ real-world conditions like partial shade and high temperatures.' When used with InvisiMount racking and InvisiMount accessories 1 -. •#.40 1441,k - , I (UL 2703): SunPower°Maxeonlqechnology 150% Solar Cells 66 Monocrystalline Maxeon Gen 5 •Module grounding and bonding through InvisiMount 14056 •Class A fire rated • Most powerful cell in home solar 2 _ High-transmission tem ered with Cl Front Glass p glassWhen used with AC module Q Cables and accessories(UL 6703 and • Delivers unmatched reliability a v 130% anti-reflective coating UL 2238)6: • Patented solid metal foundation prevents ' 120% = (;0�� 1 Up to Environmental Rating Outdoor rated •Rated for load break disconnect a breakage and corrosion 1D� 60/o Frame Class 1 black anodized(highest MMA rating) PID Test Potential-induced degradation free 10090 more a Weight 46.5 lbs(21.1 kg) C 90% - lifetime m 80% energy Recommended Max. ro (liiVii#ni+k1 Arlt fii)l(- - Module Spacing 1.3 in.(33 mm) y, 70% v1 60% . . ... ,. I- 72.21835 1 N 1 SunPower 415 W,22.3%efficient,compared to a Conventional Panel on same-sized I - 1 0 5 10 15 20 25 arrays(260 W,16%efficient,approx.1.6 mf),7.9%more energy per watt(based on 1 utocy.tr 41 ' PVsyst pan files for avg.US climate),0.5%/yr slower degradation rate(Jordan,et.al. t u Years of operation "Robust PV Degradation Methodology and Application."PVSC 2018). a 2 Based on search of datasheet values from websites of top 10 manufacturers per IHS,as of res Di January 2019. 0 .O- 3#1 rank in"Fraunhofer PV Durability Initiative forsolarModules:Part3"PVTechPower Best Reliability. Best Warranty. Magazine,2015.Campeau,Z.etal."SunPowerModuleDegradation Rate,"SunPowerwhite O ❑ in.(mm) L • a,,, s paper,2013. c ' 4 Factory set 101547a-2014 defaultsettings.CA Rule 21 default settings profile set during B- With more than 25 million modules deployed around �,. commissioning. r 5 Standard Test Conditions(1000 W/m°irradiance,AM 1.5,25°C).NREL calibration standard: I` Factoryintegrated Microinverter(MI) the world,SunPower technologyis proven to last.That's ' �'� B • Long side 1.3(32) �- SOMScurrent,LACCSFFandvoltage.All DC voltage is fullycontainedwi[hinthemodule. , F°•� ' 6 This product is UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12; • Short side 0.9(24) • Highest power integrated AC module why we stand behind our module and microinverter r(. and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors; in solarwhen installed according to manufacturer's instructions. with the industry's best 25-year Combined Power and 7 Please read the safety and installation instructions for more information regarding load • 60%lighter than prior SunPower MIs Product Warranty,including the highest Power Warranty ratings and mounting configurations. {MGdAE 0 Gel E.MC • Engineered and calibrated by See www.sunpower.com/facts for more reference information. N n�Yl UfitV °SHUTDOWN SUNPOWER® SunPower for SunPower AC modules in solar. "� For more details,see extended datasheetwww.sunpoweccom/datasheets Specifications EOLISTED E4783301APF1C1fr included in this datasheet are subject to change without notice. Module Fee Performance:Type 2 02020 SunPower Corporation.All Rights Reserved.SUNPOWER,the SUNPOWER logo, Equinox,and MAXEON are registered trademarks of SunPower Corporation in the U.S.and Please read the Safety and Installation Instructions 532628 for additional details. other countries as well.1-800-SUNPOWER. 534092 RevB 4 *� i '.". .4 r„�",r * ya yi,_ ...�.x,,, -- "Y€ f"ya,.fiV #. ty .:.�: -..u, -.t,, r,� ,,,.- ai.`q ':S .+, ram, + 5. i :.e ,,,a*"f .�- ..--,, ^`,�,. y { .. •,�f ___...._-.._. ...„::.,.,.,�.._._-..-._... .sem ,Y 1--.5., 2—•-•-- �^ ..^"5"P . , :� i__—: r dr 3 a^!y rF F i''y.s!�''/ .., .•. x.-s ,,;°4-_,.,,,-;.-„.7,',- / T. '4f-,,:k1:.-7.,..-.- _ ♦:�.. x Y}. { Vit. -•-�. . , !. _.-t„-,ETr`;'• rr ';;';':':'::f;:.)-:11 :::‘'-':-.::':'f' ..?, _::.,, x — za. " _ ca. .} "'9'i ,;:. - -- sa t i - si4a .pa F.,�� . :lr.. ..a. .. .�.,". ''''''''''''''4"*`-'''''''' r,a��d. ss ',s.- :-- y 11•a - _.. . �, .,�'. ia5n -15 ":... '".. 4r,y .. £.. . F�... a,� -.:• 1 .. tN`.. Win; '''''''''''''I'* ,.. � -+,� t 0 „ a� ,Yf n • ''..:'''''''j'''''''''''''''"4:'.:±14\ '' .,..m.a R;.'. -. 3 t .} ` ,u at3t ')v r,, ` "”" ► reJ • >m : �Ykk' Y ,'Y.n .._..,..._. ,� a Wa a :u '°„„�..- .:. : ,.:. �Lr a ..,_ pp P.�: +&e"» , . � .._ sem.. , ' �+; -Il• T a 1– c ': •► •" D I w IIP' - f f n T-0. A r-- �� © (� es.ce11 - �� o n s enn A �� � �,e o n � o nt : _• S Senn ffe(Tr d(otaDDly(((ilii,it#44:i ,,, Simple and Fast Installation Module'/Mid Clamp and Rail Module',/End Clamp and Rail • Integrated module-to-rail grounding = - c '� • Pre-assembled mid and end clamps i --"' • Levitating mid clamp for easy placement f , ` • Mid clamp width facilitates consistent,even ?4,2 tea, ii-< 5„ 4 module spacing _ . .. ,. _,,- ....--i-,..,-„,` - ' • UL 2703 Listed integrated grounding �� � � `- Flexible Design I ..x cwt Mid Clamp End Clamp Rail&Rail Splice Ground Lug Assembly(for DC systems only) • Addresses nearly all sloped residential roofs { s'_ • Design in landscape and portrait with up to 8' � '°`,.'� � • rail span .< *, , : . ; .....,p, `� : . • Pre-drilled rails and rail splice ,, .., 1,+ ,r ,, • Rails enable easyobstacle management g , "6 4a a r 4 � i 1� ... � (X+ �l�i� 1'�t d )iii�f`it=.t �� .t't. ����$��'Ia �s��.eta it �t`a4`itii Ca sr! ;» ' � #• ' )(.fit � �. I� 1. _.. Mid clamp Black oxide stainless steel 300 series 63 g(2.2 oz) Temperature —40°C to 90°C( 40°F to 194°F) Customer-Preferred Aesthetics End clamp Black anodized aluminum 6000 series 110 g(3.88 oz) • 3000 Pa uplift Max.Load(LRFD) • 6000 Pa downforce • #1 module and#1 mounting aesthetics Elegant Simplicity Rail Black anodized aluminum 6000 series 830 g/m(9 oz/ft) • Best-in-class system aesthetics Rail splice Aluminum alloy 6000 series 830 g/m(9 oz/ft) ® TM Rail bolt M10-1.5 x 25 mm;DIN 933 55304 nominal 4+ y ,1#; :��i,I1tl(l'il. ariwr(Ii,fry$i i1 t1(. "»(iy,ii t,,4 .m t-q 1 • Premium,low-profile design SunPower® InvisiMount is a SunPower designed Rail nut M10-1.5;DIN 6923 SS304 nominal • Black anodized components rail-based mounting system. The InvisiMount system Ground lug • Composition Shingle Rafter Attachment SS304;A2-70 bolt;tin-plated copper lug 106.5 g/m(3.75 oz) • Composition Shingle Roof Decking Attachment assembly Application • Curved and Flat Tile Roof Attachment • Hidden mid clamps and capped,flush addresses residential sloped roofs and combines faster Universal interface forotnerroofattachments end clamps 1i 1�t 1!"1 (i[;C alai C��r#�f f � d i t/ r,•41-r. installation time, design flexibility, and superior aesthetics. Uplift 664 lbf Part of Superior System Mid clamp iiiVeL••a4'r1,�f-k,t:aillfiif_t.�_r3ti' C:iii astir; a The InvisiMount product was specifically envisioned and Shear 540 lbf • Built for use with SunPower DC and AC modules Uplift 899 lbf • 25-year product warranty engineered to pair with SunPower modules.The resulting End clamwarranties am • Best-in-class system reliability and aesthetics• p Shear 220 lbf 5-year finish warranty system-level approach amplifies the aesthetic and New optional rooftop transition flashing,rail- y pp p Moment:upward 548 lbf-ft • UL 2703 Listed Rail Certifications • mounted J-box,and wire management rail clips installation benefits—for homeowners and for installers. Moment:downward 580 lbf-ft Class A Fire Rated • Combine with SunPower modules and Moment:upward 548 lbf-ft Rail splice SunPower EnergyLink®monitoring app p Moment:downward 580 lbf-ft lit Till irrff,ir4vaitl;,.fil(,izhyq.atrr.(i•(iUr 1 Uplift 1000 lbf -- ---- . ' L-foot Refer to roof attachment hardware manufacturer's documentation. ® Shear 390 lbf _ 1 sunpower.com 1 Moc (ware interoperability. /i; II I; I 2 SunPower recommends that all Equinox'TM,InvisiMountTM,and AC module systems always be designed using the SunPower Design Tool.If a designer decides to I „- instead use the component capacities listed in this document to design a system,note that the capacities shown are Load and Resistance Factor Design(LRFD) 7. :� design loads,and are NOT to be used for Allowable Stress Design(ASD)calculations;and that a licensed Professional Engineer(PE)must then stamp all calculations. Should you have any questions please contact SunPower Technical Support at 1-800-SUNPOWER(1-800-786-7693). r.o.pec r ` sunpower.com' O 2017 SunPower Corporation.All Rights Reserved.SUNPOWER,the SUNPOWER logo,EQUINOX,and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. 509506 RevF All other trademarks are the property of their respective owners.Specifications included in this datasheet are subject to change without notice. a � ti r •. Product Data Sheet D222NRB Product data sheet DU221 RB Safety Switch , 60A, Fusible, Cartridge (Class H, K Characteristics Safety switch, general duty, non fusible, 30A, or R), 2-Pole 2 poles, 3 hp, 240 VAC, NEMA 3R, bolt-on provision SQUARE D Product availability:Stock-Normally stocked in distribution facility by Schneider Electric List Price $326.00 USD r+' '" Q i=' i „, f - ] *' Availability Stock Item:This item is normally stocked in our distribution facility. ,,..1.7',(...:,,' j _� Price*: 177.00 USD "" P "`.� , i, 1 E.] p Technical Characteristics [ Terminal Type Lugs 1" l`' Type of Duty General Duty Maximum Voltage Rating 240VAC =' ' g Wire Size #10 to#2 AWG(AI)-#14 to#2 AWG(Cu) a Depth 4.83 Inches N Height 14.88 Inches Y w Width 6.63 Inches g a Action Single Throw S Ampere Rating 60A Main a. Approvals UL Listed File:E2875 Product Single Throw Safety Switch lo Enclosure Rating NEMA 3R Current Rating 30 A o Enclosure Type Rainproof and Sleet/Ice proof(Indoor/Outdoor) Certifications UL listed file E2875 Enclosure Material Galvannealed Steel Enclosure Rating NEMA 3R o Factory Installed Neutral Yes Disconnect Type Non-fusible disconnect switch g Fuse Type Cartridge(Class H,K or R) Factory Installed Neutral None Disconnect Type Fusible Mounting Type Surface Short Circuit Current Rating 100kA(max.depending on fuse type) Number of Poles 2 d Mounting Type Surface Electrical Connection Lugs . Number of Poles 2-Pole Duty Rating General duty Voltage Rating 240 V AC o Shipping and Ordering Wire Size AWG 14...AWG 6 copper g Category 00106-Safety Switch,General Duty,30-200 Amp,NEMA3R AWG 12...AWG 6 aluminium a Discount Schedule DE1A lo! GTIN 00785901460640 Complementary Package Quantity 1 _ Weight 8.35 lbs. Short-circuit withstand 200 kA Maximum Horse Power Rating 3 hp 240 V AC 60 Hz 1 phase NEC 430.52 m Availability Code Stock Item:This item is normally stocked in our distribution facility. Tightening torque 30 lbf.in(3.39 N.m)0.00...0.02 int(2.08...13.3 mm2)AWG 14...AWG 6) d Retumability Y Height 9.63 in(244.60 mm) Q Country of Origin US N Width 7.75 in(196.85 mm) o Maximum Depth 3.75 in(95.25 mm) As standards,specifications,and designs change from time to time,please ask for confirmation of the information given in this document. e e Ul r- Generated:06/30/2010 15:53:57 `a S d * Price is*List Price'and may be subject to a trade discount—check with your local distributor or retailer for actual price m /_ _ Mar 28,2021 �t ° ©2010 Schneider Electric.All rights reserved. rY�- 1�.f/1 1 fire Is On Sc peider 1 1 ejElectric