Loading...
HomeMy WebLinkAboutBLDE-23-001173 Commonwealth of Off icial Use Only ly' i�,, Massachusetts Permit No. BLDE-23-001173 ci. k BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:9/1/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 56 NORTH RD Owner or Tenant ESTEVAO LANDIM Telephone No. Owner's Address 56 NORTH RD,WEST YARMOUTH, MA 02673 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system (16 Panels 6.40 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiatine Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal Connection 0 Other: No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Matthew T Markham Licensee: Matthew T Markham Signature LIC.NO.: 1136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:24 SAINT MARTIN DR,BLDG 2 UNIT 11,MARLBOROUGH MA 017523060 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 RECEIVED — SEf 0 0 c / h Official Use o ly 1 21J2�o wag o� a��ac craells {�i� ��o yt •• (� Permit No. —� a,Iment o� ire_Jervice9 IL-DING DE.PARTMEN � • Occupancy and Fee Checked 'REVENTION REGULATIONS [Rev. 1/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 08/29/2022 City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 56 North Road Owner or Tenant Estevao Landim Telephone No. 774-368-8324 Owner's Address 50 North Road,West Yarmouth,MA 02673 Is this permit in conjunction with a building permit? Yes ■ No (Check Appropriate Box) Purpose of Building residential Utility Authorization No. Existing Service 200 Amps 120 /240 Volts Overhead n Undgrd n No.of Meters 1 New Service 200 Amps 120 / 240 Volts Overhead ■ Undgrd Ti No.of Meters 1 Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: roof mounted pv solar panels-6.400Kw system-16 total panels-200A Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans Tf T Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices g Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained p Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other Connection No.of Dr ers Heating Appliances KW Security Systems:* Y No.of Devices or Equivalent No.of Water No.of No.of Data Wiring: Heaters KW Signs Ballasts No.of Devices or Equivalent No. H dromassa a Bathtubs No.of Motors Total HP Telecommunications No fDeieorWiring:q al Y g No.of Devices Equivalent OTHER:roof mounted pv solar panels- 6.400Kw system- 16 total panels- 200A Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: 23763.20 (When required by municipal policy.) Work to Start:upon approval Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ❑ BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Freedom Forever Massachusetts LLC �/�/ LIC.NO.:902A1 Licensee: Matthew Markham Signature �`GG /1,C�J42, LIC.NO.:1136MR (If applicable,enter "exempt"in the license number line.) Bus.Tel. No.:774-320-553s Address: 135 Robert Treat Paine Dr.,Taunton,MA 02780 Alt.Tel.No.: *Per M.G.L.c. 147,s. 57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent PERMIT FEE: $ Signature Telephone No. PHOTOVOLTAIC SYSTEM CODES: CONSTRUCTION NOTES: THIS PROJECT COMPLIES WITH THE FOLLOWING: 2015 INTERNATIONAL BUILDING CODE CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND 2015 INTERNATIONAL RESIDENTIAL CODE ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 2018 INTERNATIONAL MECHANICAL CODE ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT 144/ONA NtHOFA/Ass 2018 INTERNATIONAL PLUMBING CODE POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE Josep Digitall nJOSEPH J. ��ybyJos2018 INTERNATIONAL FUEL GAS CODE MOUNTED. Bravo BRAVO tfi2018 INTERNATIONAL ENERGY CONSERVATION CODE MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN h J 2022.d: ELECTRICAL2015 INTERNATIONAL EXISTING BUILDING CODEACCORDANCE WITH UL 2703.SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER Bravo 12:22: I-06' No. 56193 "�2018 INTERNATIONAL SWIMMING POOL AND SPA CODESECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. A 'QFG/STER� 4``42020 NATIONAL ELECTRICAL CODEDIG ALERT(811)TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY ' AS ADOPTED BY TOWN OF YARMOUTH (MA) EXCAVATION TAKING PLACE '„ j' PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM DC DISCONNECT/INVERTER AS PER 2020 NEC SEC 250.166(A). SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH VICINITY MAP: REQUIREMENTS OF ART.690 OF THE 2020 NEC THE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM s`, -9SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY)AND UL 1741 STANDARDS CLIENT: "'� =i ESTEVAO LANDIM ' INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT 56 NORTH ROAD,WEST YARMOUTH,MA a; Z HS ATTACHED TO THE ROOF USING CONDUIT MOUNT. AT °,� z OWN OF YARMOUTH(MA) UTILITY:EVERSOURCE ENERGY(WESTERN s 4 c `9 MA) ° PHONE:(774)368-8324 9 Qv rte, 4. SYSTEM: SYSTEM SIZE(DC):16 X 400=6.400 kW 9 ' 1i r ( SYSTEM SIZE(AC):5.000 kW @ 240V MODULES:16 X TESLA:T400H OPTIMIZERS:16 X SOLAREDGE S440 INVERTER:SOLAREDGE SE5000H-US[5111 '''' (,). Ze--- c . , e, \( a ,‘„,,,,,,.,,, j a r.13 SITE LOCATION O 1- ' TABLE OF CONTENTS: PV-1 SITE LOCATION REVISIONS PV-2 SITE PLAN NO. REVISED BY DATE PV-2A ROOF PLAN WITH MODULES LAYOUT _ _ PV-2B STRUCTURAL CALCULATIONS - - _ PV-3 MOUNTING DETAILS •• . .' V PV-4 THREE LINE DIAGRAM FOREVEF PV-5 CONDUCTOR CALCULATIONS FREEDOM FOREVER LLC 135 ROBERT TREAT PAINE DR.,TAUNTON, PV-6 EQUIPMENT&SERVICE LIST MA 02780 Tel:(600)385-1075 PV-7 LABELS GREG ALBRIGHT PV-7A SITE PLACARD !( A1'I: ; U i PV-8 OPTIMIZER CHART /j' PV-9 SAFETY PLAN CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; PV-10 SAFETY PLAN BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISOR APPENDIX MANUFACTURER SPECIFICATION SHEETS LICENSE CS-111662;MASTER ELECTRICIAN 1136 MR SITE LOCATION JOB NO: DATE: DESIGNED BY: SHEET: 252369 8/24/2022 Z.V. PV-1 g - Z3 - a0 173 BARUN CORP August 25,2022 RE: CERTIFICATION LETTER Project Address: ESTEVAO LANDIM RESIDENCE 56 NORTH ROAD WEST YARMOUTH,MA 02673 Design Criteria: -Applicable Codes=2015 IBC/IEBC W/(780 CMR)9th Edition,2015 IRC W/(780 CMR)9th Edition,ASCE 7-10 and 2015 NDS -Risk Category=II -Wind Speed=140 mph,Exposure Category C,Partially/Fully Enclosed Method -Ground Snow Load=30 psf -Roof 1-3:2 x 6 @ 20"OC,Roof DL=7 psf,Roof LL/SL=25 psf(Non-PV),Roof LL/SL=16.7 psf(PV) To Whom It May Concern, A job site survey of the existing framing system of the address indicated above was performed.All structural evaluation is based on the site inspection observations and the design criteria listed above. Existing roof structural framing has been reviewed for additional loading due to installation of Solar PV System on the roof.The structural review applies to the sections of roof that is directly supporting the Solar PV System. Based on this evaluation,I certify that the alteration to the existing structure by installation of the Solar PV System meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,the Solar PV System assembly including attachment hardware has been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed the requirements set forth by the referenced codes. ( 1T' \HUMPHREY HUMPHREYKKARIUKI MPHREYKARIUKI K Sincerely, ° K KARIUKI U STRUCT Date: 2022.08.25 N°. 9 � 04, .. t 10:33:41 -04'00' ,°'� ;,.TER �� `ONAI S- STRUCT ONI.Y Ccr De,Ann a.-,` ,_ 3 A£....J i 1)202 i 506 choskndr:Andndcd nn nimn s c ,000 BARU N CORP RESULTS SUMMARY ESTEVAO LANDIM RESIDENCE,56 NORTH ROAD,WEST YARMOUTH,MA 02673 MOUNTING PLANE STRUCTURAL EVALUATION ROOF PITCH MOUNTING PLANE (de RESULT • GOVERNING ANALYSIS . • g.) . Roof 1-3 30° OK IEBC IMPACT CHECK STANDOFF HARDWARE EVALUATION FOR WIND UPLIFT MOUNTING PLANE WIND UPLIFT OCR Roof 1-3 57.9% 0-nip of_Sbcgage of Work and babiliwg The existing structure hos been reviewed based on the assumption that it has been originally de.signed and constructed per appropriate codes. The structural analysis of the .subject property ie based on the provided site survey data. The calculations produced for this structure's assessment are only for the roof framing.upporting the proposed PP in.i.btailation referenced in the.stamped planer and were made according to generally recognized structurol analy.sis standards and procedures, AU PV modules, racking and attachment components,shall be designed and bistaited per manufacturer's approved guidelines and specification.s.These plans are not stamped for water leakage or existing damage to the structural component that was not accessed during the site.survey,Prior to commencement:of work,the PV system installer.should verify that the existing roof and connections ore in suitable condition and inspect framing noted on the certification letter and inform the Engineer of Record of any discrepancies prior to installation.The installer shouhi also check for any damages such as water damage, cracked'taming, etc. and inform the Engineer of Record of existing deficiencies which are unknown or Were not ob.servable during the.,rirne of surrey and I-brie nOt hen included in this.5Cope of WOrk,Any change in the„scope of t?..,e work shall not be occepted unless such change.,addition,or deletion is approved in advance and in writing by the Engineer of Record, Baron Ocap I Dean go and EdnIneenng 61()202 45.nai anra;kwarundoorp,corn 1 adann nna;nadd n,n,n, F BARUN CORP LOAD CALCULATION Roof 1-3 ESTEVAO LANDIM RESIDENCE,56 NORTH ROAD,WEST YARMOUTH,MA 02673 PV PANELS DEAD LOAD(PV-DL) PV Panels Weight = 2.50 psf Hardware Assembly Weight = 0.50 psf Total PV Panels Weight PV-DL= 3.00 psf ROOF DEAD LOAD(R-DL) Existing Roofing Material Weight Composite Shingle Roof I tayer(s) = 2.50 psf Underlayment Weight = 0.50 psf Plywood/OSB Sheathing Weight = 1.50 psf Framing Weight 2 x 60 20 in.Cf.C. = 1.38 psf No Vaulted Ceiling =0.00 psf Miscellaneous = 1.50 psf Total Roof Dead Load R-DL= 7.40 psf REDUCED ROOF LIVE LOAD(Lr) Lo= 20.00 psf Roof Live Load At< 200 ftz Member Tributary Area Roof 1-3 Pitch 30°or 7/12 Tributary Area Reduction Factor R1= 1.00 Roof Slope Reduction Factor R2=0.85 Reduced Roof Live Load,Lr=Lo(R1)(R2) Lr= 17.00 psf SNOW LOAD Ground Snow Load pg= 30.00 psf Effective Roof Slope 30° Snow Importance Factor Is= 1.00 Snow Exposure Factor Ce= 1.00 Snow Thermal Factor Ct= 1.10 Minimum Flat Roof Snow Load pf-min= 25.00 psf Flat Roof Snow Load pf= 25.00 psf SLOPED ROOF SNOW LOAD ON ROOF(Non-Slippery Surfaces) Roof Slope Factor Cs-roof= 1.00 Sloped Roof Snow Load on Roof ps-roof= 25.00 psf SLOPED ROOF SNOW LOAD ON PV PANELS(Unobstructed Slippery Surfaces) Roof Slope Factor Cs-PV= 0.67 Sloped Roof Snow Load on PV Panels ps-PV= 16.70 psf BARUN CORP IEBC IMPACT CHECK Roof 1-3 ESTEVAO LANDIM RESIDENCE,56 NORTH ROAD,WEST YARMOUTH,MA 02673 EXISTING WITH PV PANELS Roof Dead Load(DL)= 7.40 10.40 psf Roof Live Load(Lr)= 17.00 0.00 psf Roof Snow Load(SL)= 25.00 16.70 psf EXISTING WITH PV PANELS (DL+Lr)/Cd= 19.52 11.56 psf (DL+SL)/Cd= 28.17 23.57 psf Maximum Gravity Load= 28.17 23.57 psf Load Increase(%)= -16.36% OK IEBC Provision: 2015 The requirements of section 807.4 of 2015 IEBC are met and the structure is permitted to remain unaltered. nd F nineerifla 6;6 202 ',1 ,a r),;,cOft: BARUN CORP WIND UPLIFT CALCULATION Roof 1-3 ESTEVAO LANDIM RESIDENCE,56 NORTH ROAD,WEST YARMOUTH,MA 02673 SITE INFORMATION Ultimate Wind Speed= 140.00 mph Roof Pitch= 30* Risk Category= II Roof Type= Gable Exposure Category= c Wind Directionality Factor,Kd= 0.85 Mean Roof Height= 20.00 ft Topographic Factor,Kzt= 1 Solar Array Dead Load= 3.00 psf Velocity Pressure Exposure Coeff.,Kz= 0.90 DESIGN CALCULATIONS Wind Velocity Pressure(qh)=0.00256*Kz*Kzt*Kd*Ke*V2= 38.47 psf a(ft)= 3.00 Array Edge Factor(yE)= 1.50 Solar Array Pressure Equalization Factor(ya)= 0.60 Allowable Load= 982.50 lbs S.Pine,2.5"lag embedment Max.X-Spacing(Zone 1-2r) 3.33 ft Effective Wind Area Max.Y-Spacing(Zone 1-2r) 3.50 ft 11.66 ft2 Max.X-Spacing(Zone 2n&3r) 3.33 ft Effective Wind Area Max.Y-Spacing(Zone 2n&3r) 3.50 ft 11.66 ft2 Max.X-Spacing(Zone 3e) 3.33 ft Effective Wind Area Max.Y-Spacing(Zone 3e) 3.50 ft 11.66 ft2 ROOF ZONE GCp(-)UPLIFT UPLIFT PRESSURE PULLOUT FORCE 1-2r -1.73 -34.45 psf 401.49 lbs 2n&3r -1.95 -38.92 psf 453.63 lbs 3e -2.43 -48.83 psf 569.16 lbs NOTE: •Wind calculation is based on ASCE 7-16,29.4-C&C,LC#7:0.6D+0.6W is used. ,r.1 1(h, \:„ LEGEND: TOTAL ROOF AREA RIDGE SETBACK CALCS: TOTAL ROOF AREA: 1727.92 SQ FT OBSTRUCTION SINGLE MODULE AREA: 21.27 SQ FT , P\,ZHOFR/4ss, TOTAL NUMBER OF MODULES: 16 • a c 0 PIPE VENT TOTAL AREA OF MODULES: 340.32 SQ FT o JOSEPH J. yG a ROOF COVERAGE: 19.70% `o ELECTRICAL_ BRAVOrn MODULES FIRE SPRINKLERS: NO " No. 56193 '') - — - CONDUIT BOS WILL BE AS CLOSE AS POSSIBLE TO MSP WITHIN 10' \ N A 'PFG/$TES SETBACK PV SYSTEM / (t l'in ja ' 6.400 kW-DC �' / A c AC 5.000 kW-AC �� \ DISCONNECT MSP (E)UTILITY TRANSFORMER �� MSP 85'NW OF METER, POLE MOUNTED • FENCE/GATE ...1B JUNCTION (E)UTILITY METER N • BOX N • INV INVERTER (N)MAIN SERVICE PANEL • um UTILITY PROPERTY LINE O,Q • • / • METER \ /'q I \ \ �ry• • ROOF AREA:1727.92 SQ FT \ /� • • CLIENT: // . • ESTEVAO LANDIM 56 NORTH ROAD,WEST YARMOUTH,MA • 02673 AHJ:TOWN OF YARMOUTH(MA) UTILITY:EVERSOURCE ENERGY(WESTERN • MA) ` PHONE:(774)368-8324 / • / P • I* • $YSTEM: SYSTEM SIZE(DC): X =6.400 kW • SYSTEM SIZE(AC):5.000 kW Q 240V MODULES:IZE . X TESLA:SOLAREDGET400H OPTI INVER ER:S:16 X EDGE500 S4H-U0 • INVERTER:SOLAREDGE SE5000H-US[SI1] '64* • (N)UTILITY DISCONNECT EATON DG222NRB(OR EQUIVALENT) WITHIN 10'FEET OF, IN VISIBLE SIGHT OF,AND ON THE SAME WALL REVISIONS AS THE UTILITY METER N • NO. REVISED BY DATE (N)SOLAREDGE SE5000H-US[SII] \ - - - INVERTER WITH RAPID SHUTDOWN • - - - (N)JUNCTION BOX [reee • FoacvcF (N) 16 TESLA:T400H • FREEDOM FOREVER LLC • 135 ROBERT TREAT PAINE DR.,TAUNTON, ROOF LINE • MA 02780 • Tel:(800)385-1075 FENCE • GREG ALBRIGHT • • 1 it1),,,\/' 19‘hl id • • CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-Al;CONSTRUCTION SUPERVISOR `A, SITE PLAN LICENSE CS-111662;MASTER ELECTRICIAN 1136 MR NO SCALE: 1"=20' (1). SITE PLAN JOB NO: DATE: DESIGNED BY: SHEET: 252369 8/24/2022 Z.V. PV-2 LEGEND: MODIFIED SETBACKS PROPOSED AT RIDGE: t��P��H oFM461% OBSTRUCTION TOTAL ARRAY AREA=425.4 SF TOTAL ROOF AREA= 1727.92 SF HUMPHREY K. m 0 PIPE VENT TOTAL ARRAY AREA AS A%TO ROOF AREA=24.62% STRUCT K[ L` Zi 24.62%<33% NO. . 93 ` 0 MODULES -)113" ,1444.TE- ' - -- - CONDUIT BOS WILL BE AS CLOSE AS POSSIBLE TO MSP WITHIN 10' V S/ONAL EN STRUCT ', , PV SYSTEM ONLY SETBACK 6.400 kW-DC Digitally signed by Ac AC 5.000 kW-AC HUMPHREY HUMPHREY K DISCONNECT MSP MSP (N)SOLAREDGE SE5000H-US[SII] I INVERTER K KA R I U KI DDate:ate:2 2022.08.25 JB JUNCTION 10:34:22-04'00' BOX (N)AC DISCONNECT EATON DG222NRB(OR EQUIVALENT) INV INVERTER WITHIN 10'FEET OF, IN VISIBLE SIGHT OF,AND ON THE SAME WALL AS THE UTILITY METER ` um UTILITY METER ROOF AREA:1727.92 SQ FT (E)UTILITY METER N MAIN SERVICE PANEL CLIENT: ( ) *.�® ESTEVAO LANDIM 56 NORTH ROAD,WEST YARMOUTH,MA .44144 TL TOWN YARMOUTH(MA) UTILITY:EVERSOURCE ENERGY(WESTERN MA) (N)JUNCTION BOX PHONE:(774)368-8324 41111111hb "Fr (N) 16 TESLA:T400H ROOF LINE 0 SYSTEM: ,Ir SYSTEM SIZE(DC):16 X 400=6.400 kW SYSTEM SIZE(AC):5.000 kW @ 240V MODULES:16 X TESLA:T400H OPTIMIZERS:16 X SOLAREDGE S440 INVERTER:SOLAREDGE SE5000H-US[SII] 4 p REVISIONS NO. REVISED BY DATE 4 0 . _ . • ' ' 'ila re e di 0 nil _.. F OREVFP FREEDOM FOREVER LLC 135 ROBERT TREAT PAINE DR.,TAUNTON, MA 02780 Tel:(800)385-1075 GREG ALBRIGHT ;I),,/ 041H CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISOR g illROOF PLAN NOTES: 1136 MRMASTER ELECTRICIAN ver4110 1. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS LICENSE CS-111662; SCALE: 1/8" = 1�-OIC 2. ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES ROOF PLAN WITH MODULES LAYOUT 3. JUNCTION BOX IS MOUNTED TO THE RAIL. JOB NO: DATE: DESIGNED BY: SHEET: 252369 8/24/2022 Z.V. PV-2A • 14OFMq O�� 90 yG HUMPHREY K. m KARIUKI -+ U STRUCT L`, i NO. . 93 \P..,j= .TER ,14 ROOF DETAILS: ST V CT s'°�A�EN 2. ONLY TOTAL ROOF AREA: 1727.92 SQ FT ARRAY COVERAGE: 24.62% SYSTEM DISTRIBUTED WEIGHT: 1.95 LBS SFM INFINITY\ ROCKIT MICRORAIL POINT-LOAD: 11.65 LBS ROOF AREA STATEMENT CLIENT: ESTEVAO LANDIM ROOF MODULE QUANTITY ROOF PITCH ARRAY PITCH AZIMUTH ROOF AREA ARRAY AREA 56 NORTH ROAD,WEST YARMOUTH,MA 02673 1 16 30° 30° 124° 613.16 SQ FT 340.32 SQ FT AHJ:TOWN OF YARMOUTH(MA) UTILITY:EVERSOURCE ENERGY(WESTERN 2 2 30° 30° 214° 160.51 SQ FT 42.54 SQ FT PHONE:(774)368-8324 3 2 30° 30° 34° 191.05 SQ FT 42.54 SQ FT SYSTEM: SYSTEM SIZE(DC):16 X 400=6.400 kW SYSTEM SIZE(AC):5.000 kW @ 240V MODULES:16 X TESLA:T400H OPTIMIZERS:16 X SOLAREDGE S440 INVERTER:SOLAREDGE SE5000H-US[SI1] REVISIONS _ NO. REVISED BY DATE FOR E V E R FREEDOM FOREVER LLC 135 ROBERT TREAT PAINE DR.,TAUNTON, MA 02780 Tel:(800)385-1075 GREG ALBRIGHT(_1164-1 CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-Al;CONSTRUCTION SUPERVISOR LICENSE CS-111662;MASTER ELECTRICIAN 1136 MR ROOF DETAILS JOB NO: DATE: DESIGNED BY: SHEET: 252369 8/24/2022 Z.V. PV-2B • LEGEND ( � ,- - — ri..— — ,:--- i— — t�P��HOFMgSS W tai u+i . W .. tw Ss Ory, �0 C. d HUMPHREY K. (Roof Zones) - . r , - - rModule . ITI 8 KARIUKI % -- ... _----... __.w.a. iiii STRUCT L` Ii NO. . 93 1 , Zone 1 + 1i ` ' , <Ci r ,.i TER Q Zone 241 .�.. �.„ ._..-1 - Li;i . ` SAO AL ANG I-1 'awe 3 f ( STRUCT TI ONLY L_ S� SFM Components -6.1....m.,______,,":' "" �: "MY . `°' ._,i••---.6i,-66... s=Pd A"icrorail2" ECU S=1.1 Attached 1 :' 9 1 )S' S2;ICe 2i"0 Li� j • w�i:u tial iai�i S I !.):;MTr;m � �' J:i �a.i Attachment "' �` S ., tt u, SMS Trim Una,r ,i e 4 C'ip , 1=3 ,_ U .. Full Trim Section CutTT7mSecton Mount Coupling Rafter Skirt Ground Lug CLIENT: NUMESTEVAO LANDIM 56 NORTH ROAD,WEST YARMOUTH,MA 02673 AHJ:TOWN OF YARMOUTH(MA) UTILITY:EVERSOURCE ENERGY(WESTERN PARTIAL ROOF FRAMING PLAN MA) PHONE:(774)368-8324 Scale: NTS • SYSTEM: SYSTEM SIZE(DC):16 X 400=6.400 kW SYSTEM SIZE(AC):5.000 kW @ 240V u; MODULES:16 X TESLA:T400H OPTIMIZERS:16 X SOLAREDGE S440 Z INVERTER:SOLAREDGE SE5000H-US[SI1] MICRORAIL // 11111 /1 /1 /, \1 // 1111 TRIMRAIL TESLA:T400H ///..'.'/�////////j1/ _.„,/ TESLA:T400H TESLA::T400H /404 rj SLIDER AND TRIMRAIL 1111/// . ■ MEM ROOF ATTACHMENT -'A- 1joifi 1j1 ♦ SLIDERS LASHING �L�[�� �, ECK MEMBRANE ROOF DECK/ 1/1// i MEMBRANE REVISIONS / ROOF/DECK MEMBRANE ►iiiiiiiUIZAVIiiii _!i/ZIP7 A. ►/iii/IMIP7I /i i/. //1///1/// FLASHING is wax.emeeo.. ii; - - Y A TRIMRAIL //////// 5/16"STAINLESS STEEL LAG NLESS STEEL ORAL SCREW AND FLAT e ed.'Y �ro.� Y ` %%j1 BUILDING STRUCTURE ORE V E //1//# /, BUILDING STRUCTURE SLIDER AND TRIMRAIL ROOF FREEDOM FOREVER LLC 001",,50. ATTACHMENT 135 ROBERT TREAT PAINE DR.,TAUNTON, FLASHING MA 02780 Tel:(800)385-1075 5/16"STAINLESS STEEL LAG BOLT OR STRUCTURAL SCREW GREG ALBRIGHT WITH 2-1/2"MIN.EMBEDMENT AND FLAT WASHER tijx..A1 J , V�.�J_`II il CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISOR SOLAR PV ARRAY SECTION VIEW ATTACHMENT DETAIL LICENSE CS-11161136M MASTER ELECTRICIAN 1136 MR Scale: NTS Scale: NTS MOUNTING DETAILS JOB NO: DATE: DESIGNED BY: SHEET: 252369 8/24/2022 Z.V. PV-3 • BACKFEED FUSE SIZING MAX.CONTINUOUS OUTPUT 21.00A @ 240V 21.00 X 1.25 = 26AMPS 30A FUSES-OK -.0""4444.-- PV SYSTEM • OF40 6.400 kW-DCd J 5.000 kW-AC (\ \k BRAVOrn ELECTRICAL zi . 56193FS �Siota y. •CLIENT: (N)200A RATED — (E)UTILITY METER ESTEVAO LANDIM MAIN SERVICE PANEL 56 NORTH ROAD,WEST YARMOUTH,MA 1 Pli,120/240V 60HZ 02673 IAHJ:TOWN OF YARMOUTH(MA) STRING-1 (N)200A/2P — UTILITY:EVERSOURCE ENERGY(WESTERN 8 TESLA:T400H MAIN BREAKER MA) (END FED) PHONE:(774)368-8324 ELI _ I , SOLAREDGE S440 .- POWER OPTIMIZERS —2-#10 AWG, SYSTEM: _ __ _ SYSTEM SIZE(DC):16 X 400=6.400 kW r — I PV WIRE • • SYSTEM MODULES:16 XZE AC):TESLA:OkW T400H�240V MI ill[ -- V (N)SOLAREDGE WITHIN 10' FEET OF, IN VISIBLE SIGHT OF,AND I OPTIMIZERS:16XSOLAREDGES440r SE INVERTS[SIT] INVERTER ON THE SAME WALL AS THE UTILITY METERINVERTER:SOLAREDGESE5000H-US[SII] AC (N)LIS LINESIDE TAP VIA UL STRING-2 (N)60A FUSEDLISTED CONNECTOR AC DISCONNECT 8TESLA:T400HD^ _ EATON DG222NRBT)(OR /v' EQUIVALENT)7G • 2-30AMP FUSEStJUNCTION — , — ctf�/o - rounuTY BOX _ _ _ _ OLf G O_ — - OVERHEAD .. DI 1 bbb bbb �\ FEED I —RAPID -r T �(��®�j[ I — RA AMC ----\/1 ` — 4-#10 AWG,THWN-2 SHUTDOWN SWITCH 1-#8 EGC,THWN-2 ,�_ —3-#10 AWG,THWN-2 .— 3-#6 AWG,THWN-2 LREVISIONS IN 3/4'OR 1-#3 EGC,THWN-2 1-#8 EGC,THWN-2 o c o c NO. REVISED BY DATE 7 ( - LARGER EMT CONDUIT IN 3/4"OR LARGER EMT IN 3/4"OR LARGER EMT _ _ I Isis- CONDUIT CONDUIT • L - - - - T - - - SOLAREDGE S440— POWER OPTIMIZERS A TAPBOX MAY BE USED IN LIEU OF PERFORMING THE LINESIDE 2-#10 AWG,PV WIRE TAP IN THE MAIN SERVICE PANEL.THIS IS DEPENDENT UPON SITE / n 1-#6 AWG IN FREE AIR OR ' � CONDITIONS. #8 AWG MUST BE IN EMT CONDUIT FOREVER CONNECT TO EXISTING UFER FREEDOM FOREVER LLC 135 ROBERT TREAT PAINE DR.,TAUNTON, MA 02780 Tel:(800)385-1075 IGREG ALBRIGHT 3,1,-,/ AN— / 1 THE PRODUCTION METER AND AC DISCONNECT WILL BE LABELED WITH THE HOME IMPROVEMENT CONTRACTOR 198080; LOCATION OF THE UTILITY METER.A PLACARDON THE UTILITY METER BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-Al;CONSTRUCTION SUPERVISOR WILL SHOW THE LOCATION OF THE PRODUCTION METER LICENSE CS-111662;MASTER ELECTRICIAN NOTE: 1136 MR LOCKABLE DISCONNECT,WITHIN 10' OF THE METER, MUST BE PROVIDED THAT IS ONNDNIAND CODE REQUIREMENTS AND ARE NOT MEANT THREE LINE DIAGRAM READILY ACCESSIBLE AT ALL TIMES TO THE ASSOCIATION'S PERSONNEL. TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS JOB NO: DATE DESIGNED BY: SHEET: 252369 8/24/2022 Z.V. PV-4 '‘‘k OF JOSEPH J. ry o BRAVO LP rl o ELECTRICAL .-, " No. 56193 ti 'FFS/ONA • L��`� (47 WIRE SCHEDULE CLIENT: ESTEVAO LANDIM STARTING ADJUSTMENT MAXIMUM 56 NORTH ROAD,WEST YARMOUTH,MA STARTING TEMPERATURE ADJUSTED 02673 AWG CURRENT FACTOR FOR CURRENT AHJ:TOWN OF YARMOUTH(MA) RACEWAY CONDUCTOR ALLOWABLE CORRECTION CONDUCTOR EQUIPMENT WIRE LOCATION WIREAPPLIED TO MORE THAN 3 APPLIED TO UTILITY:EVERSOURCE ENERGY(WESTERN # QTY. AMPACITY @ 90°C FACTOR AMPACITY SIZE CONDUCTORS CONDUCTORSCONDUCTORSMA) 310.15(8)(16) IN RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) ©90°C IN RACEWAY PHONE:(774)368-8324 1 DC MODULE TO OPTIMIZER ROOF/FREE-AIR 2 10 40 13.93 1 1 40.00 17.41 2 DC OPTIMIZER TO JUNCTION BOX ROOF/FREE-AIR 2 10 40 15.00 1 1 40.00 18.75 3 DC JUNCTION BOX TO INVERTER EXTERIOR WALL 4 10 40 15.00 1 0.8 32.00 18.75 SYSTEM: SYSTEM SIZE(DC):16 X 400=6.400 kW 4 AC INVERTER TO AC DISCONNECT EXTERIOR WALL 3 10 40 21.00 1 1 40.00 26.25 SYSTEM SIZE(AC):5.000 kW @ 240V MODULES:16 X TESLA:T400H 5 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 21.00 1 1 75.00 26.25 OPTIMIZERS:16 X SOLAREDGE S440 INVERTER:SOLAREDGE SE5000H-US[SII] REVISIONS NO. REVISED BY DATE V Veed nil FOREV( R FREEDOM FOREVER LLC 135 ROBERT TREAT PAINE DR.,TAUNTON, MA 02780 , Tel:(800)385-1075 GREG ALBRIGHT CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-A1:CONSTRUCTION SUPERVISOR LICENSE CS-111662;MASTER ELECTRICIAN 1136 MR CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. CONDUCTOR CALCULATIONS JOB NO: DATE: DESIGNED BY: SHEET: 252369 8/24/2022 Z.V. PV-5 BREAKER SIZES: SERVICE LIST: TRUE I— ' H OF1,1gS3�OSEPH J.\�yBRAVO ` + l ELECTRICAL No. 56193 "°� ''F6/STER ��� ' FF/ S/ONA ;1„,. tiz,virrn-rnv‘VIAJW" MATERIAL LIST: QTY. PART PART# DESCRIPTION 16 MODULES 120-400 TESLA:T400H 16 OPTIMIZERS S440 SOLAREDGE S440 POWER OPTIMIZER-FRAME MOUNTED MODULE ADD-ON 1 JUNCTION BOX 480-276 600VDC NEMA 3R UL LISTED JUNCTION BOX 2 CONNECTORS 240-300 STAUBLI/MULTI-CONTACT MC4 CONNECTORS(FEMALE) 2 CONNECTORS 240-301 STAUBLI/MULTI-CONTACT MC4 CONNECTORS(MALE) 1 INVERTER 120-501 SOLAREDGE SE5000H-US[SI1]240V INVERTER UL1741 SA CERTIFIED INTEGRATED ARC FAULT PROTECTION AND RAPID SHUTDOWN 1 AC DISCONNECT 323-061 60A RATED 240VAC NEMA 3R UL LISTED CLIENT: 2 FUSES 330-030 30A FUSE 1 PH 240VAC 56 NOR O LANDIM 56 NORTH ROAD,WEST YARMOUTH,MA 1 FUSE REDUCER 330-530 30A-60A FUSE REDUCER 02673 89 ROOF ATTACHMENT 1 261-602 SFM INFINITY\ROCKIT MICRORAIL AHJ:TOWN OF YARMOUTH(MA) 15 SFM TRIM 1 241-253 FLASHKIT SFM/ROCK-IT TRIM COMP DARK UTILITY:EVERSOURCE ENERGY(WESTERN MA) 38 SFM SLIDER 1 261-603 FLASHKIT SFM/ROCK-IT SLIDER COMP DARK PHONE:(774)368-8324 11 BONDING CLAMP 1 221-100 N/S BONDING CLAMP 5 BONDING CLAMP 1 241-404 TRIM BONDING CLAMP 21 MOUNT ASSEMBLY 1 241-405 MLPE MOUNT ASSY 12 SFM SPLICE 1 261-604 SFM/ROCK-IT SPLICE SYSTEM: 3 SFM ATTACHED SPLICE 1 211-101 ATTACHED SPLICE 8 INCH SYSTEM SIZE(DC):16 X 400=6.400 kW 17 TRIMRAIL 1 261-606 TRIMRAIL UNIV CLIP W/HDW SYSTEM SIZE(AC):5.000 kW @ 240V MODULES:16 X TESLA:T400H 5 TRIM SPLICE 1 261-605 TRIM SPLICE DRK OPTIMIZERS:16 X SOLAREDGE S440 INVERTER:SOLAREDGE SE5000H-US[SI1] 9 TRIMRAIL 1 211-115 TRIMRAIL UNIV DRK 20 GROUND LUG 1 260-585 ILSCO GROUND LUG 20 TRIM END CAPS 1 221-200 UNIRAC SFM /ROCK-IT TRIM END CAPS MANUFACTURER PART DESCRIPTION SUM BOX CODU' • ' MODULES REVISIONS Tesla T400H(40mm) 1890mm(74 41')x 1046mm(41.18) 20 20 - NO. REVISED BY DATE MOUNTS&L-FEET - - Rocklt 2011 013 RI COM SLIDE AL BLK 57 57 50 , �� vee w,r Rocklt 2011020 RI MOUNT AL ELK 57 : 57 24 1� F b0ap (V E P t FREEDOM FOREVER LLC 1 135 ROBERT TREAT PAINE DR.,TAUNTON, Rocklt 3012020 GF-1 FLASHING GLV ELK 8X10 57 57 50 MA 02780 Tel:(800)385-1075 GREG ALBRIGHT CLAMPS&GROUNDING f ,Ip4\-- Rocklt 2011 021 RI COUPLING AL LBK 22 : 22 24 jj),...../ U' CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; ACCESSORIES BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISOR Rocklt 2099 012 Array Skirt,80 in,40mm 10 : 10 8 LICENSE CS-111662;MASTER ELECTRICIAN 1136 MR Rocklt N/A Grounding lug(Not Provided Ey EcoFasten) 3 : 3 EQUIPMENT&SERVICE LIST JOB NO: DATE: DESIGNED BY: SHEET: 252369 8/24/2022 Z.V. PV-6 ilYT I- .n 1:r: o 1,11" NOTES: ici' 1 ivil i Vi r' - SOLAR PV SYSTEM EQUIPPED 1. NEC ARTICLES 690 AND 705 AND IRC SECTION R324 • MARKINGS SHOWN HEREON. 690.13(B) ` WITH RAPID SHUTDOWN 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: \�HOF1,/gs II.D ©, 1 I I D 1 �,1 L. 1 r . A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR '" 0 _ . o JOSEPH J.Sq��G ILO `I iL1Ayuj TURN RAPID MACHINE PRINTED LETTERS OR ELECTRO-PLATING. BRAVO �"` B. RED BACKGROUND COLOR WHITE TEXT AND LINE NEC 690.15(B)&NEC 690.33(D)(2) SHUTDOWN SWITCH TO WORK. o ELECTRICAL _, No. 56193 40 A WARNING THE "OFF" POSITION TO SIGNS ARIAL LOBI. A �� °u.E °R'° 3. ALL SHALL BE SIZED APPROPRIATELY AND PLACED IN �,, G/SrER,�t4, w__. ._.. _.e __ ..... SHUT DOWN PV SYSTEM THE LOCATIONS SPECIFIED.SIGNAGE CANNOT BEs,6/ONA �' SINGLE 120-VOLT SUPPLY - HAND-WRITTEN. 271.4Yrm7VO' • DO NOT CONNECT AND REDUCE SHOCK U 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT r / MULTIWIRE BRANCH CIRCUITS HAZARD IN THE ARRAY WITH POP-RIVETS OR SCREWS NEC 710.15(C)&692.9(C) IFC 605.11.3.1(1)&690.56(C) AWARNING DUAL POWER SOURCE _ A CAUTION SECOND SOURCE IS PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED `y� ��,`1� ' / NEC 705.12(D)&NEC 690.59 NEC 705.12(D)&NEC 690.59 1 r`'i fl (0)i I'.o)'/'`��I`i IJA R C) A WARNING 1 1 1L-_. OWARNING WARNING 1 ..._..__..a.�... ..._...._....:... ... ..�..,.....,._..:._. _....,...:...., ARC FLASH AND SHOCK HAZARD -_-... POWER SOURCE OUTPUT t TURN OFF PHOTOVOLTAIC - - - -- APPROPRIATE j f { '�jy �,. r CONNECTION.DONOT A 1D C? ID) 1v7O) R' iMG,t�1f AC DISCONNECT PRIOR TO . RELOCATE THIS °°M•nOC«Ρ ^°• •COVER-REMOVED N..LIMITED•^wO•^ OVERCURRENT DEVICE ""_"CII""T""'"P`"="=.•,�.=u...GLOVES NEC 690.13(6) .0',PROP..SOO V CLASS 00 GLOWS WORKING INSIDE PANEL � - , . . o ..-» ,.Pa.wE,,....... ,,req -� -� �/�� V . NEC 705.12(C)&NEC 690.59 NEC 706.15(C)AND NEC 110.16 I i MM P 1 1W)�; A/'--)t- iil ESTEVAO LANDIM NEC 110.27(C)&OSHA 1910.145(F)(7) o o � 1/ANM 56 NORTH ROAD,WEST YARMOUTH,MA A WARNING �Iiso o L 11/� c 02673 AHJ:TOWN OF YARMOUTH(MA) 1 r ` `4 UTILITY:EVERSOURCE ENERGY(WESTERN __.. © r FAN/ C 1�) 1 I l M 1 ELECTRICAL SHOCK HAZARD l . (.) - ' i � t r, - 1 NEC 690.53 PHONE(774)368-8324 TERMINALS ON THE LINE AND Q F 1©) C;'"^ "1 c''(%1 LOAD SIDES MAY BE ENERGIZED NEC 690.13(B) A WARNING IN THE OPEN POSITIONr ,._.._... 4~r„("o)1rio1V 111 i1rc W e iolK,icr iiii0I-c 1I ELECTRICAL SHOCK HAZARD SYSTEM: 706.15(C)(4)&690.13(B) *$,,,100. 1,1-e j I+, ,.�€ w/M] TERMINALS AOTHE NERINE AND SYSTEM SIZE(AC):5. X k =6.400 kW A WARNING -- r'%Y0i ' Y Lvx 1 is j �~,°` I 21,00AI SYSTEM SIZE AC:S.000 kW 240V 2 LOAD SIDES MAY BE ENERGIZED ( ) °e MODULES:16 X TESLA:T400H 4. :1- I IN THE OPEN POSITION [`\ 13 I 24UV OPTIMIZERS:16 X SOLAREDGE S440 _T.. DC VOLTAGE IS ALWAYS PRESENT INVERTER:SOLAREDGE SE5000H-US[SII] THIS EQUIPMENT FED BY WHEN SOLAR MODULES MULTIPLE SOURCES: NEC 690.54 ARE EXPOSED TO SUNLIGHT TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN POWER �± 706.15(C)(4)&690.13(B) SUPPLY SHALL NOT EXCEED - AWARNING DUAL POWER SOURCE AMPACITY OF BUSBAR I NEC 705.12(8)(3)(3) SECOND SOURCE IS PHOTOVOLTAIC SYSTEM T T A WARNING N G - ► INVERTER ' NEC 705.12(D)&NEC 690.59 . A WARNING EL T SH -_ _ - - _ - _ - __ � ELECTRICAL SHOCK HAZARD DC J�� - TERMINALS ON THE LINE AND THE DISCONNECTION OF THE �'�� LOAD SIDES MAY BE ENERGIZED _L/ IT-14Y? D G .,C IN THE OPEN POSITION REVISIONS GROUNDED CONDUCTOR(S) - - - -� MAY RESULT IN OVERVOLTAGE • EVERY 10'ON CONDUIT AND ENCLOSURES 1 706.15(C)(4)&690.13(B) NO. REVISED BY DATE ON THE EQUIPMENT 1 NEC 690.31(0)(2) NEC 690.31(E) I A WARNING I! nr0� 1t)rVc ��oA�� 01�1'7c iw1� ]nl0 �i+ � f1` o i.G ez, EVERY 10ON CONDUIT AND ENCLOSURES TURN OFF PHOTOVOLTAIC FOREVEP c1/61 O Z iC V/faNireNEC 690.31(D)(2) AC DISCONNECT PRIOR TO FREEDOM FOREVER LLC 135 ROBERT TREAT PAINE DR.,TAUNTON, WORKING INSIDE PANEL MA 02780 690.56(C)(3) I�,►a"r,4r IiI,t�I+!v')' hIcr I480 I I 1 NEC 110.27(C)&OSHA 1910.145(F)(7) Tel:(Boo)385-1075 ... ------ GREG ALBRIGHT 1Wiliqibli "11 z r�1 s Ii 3.5 C ARRAY ,sir :,i4f.1.-. st 1Zikii-Vi,T .. 115 '` ii),--,/ u ✓1 0)1 ')a L41NNW3CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISOR LICENSE CS-111662,MASTER ELECTRICIAN 1136 MR LABELS NEC 690.31'G"3'&(4) JOB NO: DATE: DESIGNED BY: SHEET: 252369 8/24/2022 Z.V. PV-7 „ '‘H OF l 4ssq J.. BRAVO m ELECTRICAL No. 56193 ”) -O, 'PeC/STER ��� 1° FFSiONA t • U N.:74,„„mv‘v _tectit4, 1‘7 • CAUTION IIE POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH CLIENT: DISCONNECTS AS SHOWN 5STEVAOLANDIM 56 NORTH ROAD,WEST YARMOUTH,MA 02673 . AHJ:TOWN OF YARMOUTH(MA) UTILITY:EVERSOURCE ENERGY(WESTERN INVERTER EQUIPPED MA) PHONE:(774)368-8324 I/MAIN WITH RAPID SHUTDOWN AC DISCONNECT UTILITY METER SYSTEM:SIZE(DC):16 X 400=6.400 kW SYSTEM SIZE(AC):5.000 kW @ 240V SERVICE PANEL Aiiy.' , MODULES:16 X TESLA:T400H OPTIMIZERS:16 X SOLAEDGE E GE500 S44H-U0 JUNCTION BOX INVERTER:SOLAREDGESE5000H-US[SIt] • r16 PV MODULES ,,,,41F14411.-- I,IREVISIONS WARNING NO. REVISED BY DATE TURN OFF PHOTOVOLTAIC AC DISCONNECT - PRIOR TO WORKING INSIDE PANEL N ireecJ© ill FOREVER FREEDOM FOREVER LLC 135 ROBERT TREAT PAINE DR.,TAUNTON, MA 02780 Tel:(800)385-1075 GREG ALBRIGHT NOTES: )/� A-il 1. NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON. CONTRACTOR LICENSE: 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: HOME IMPROVEMENT CONTRACTOR 198080; A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISOR B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. LICENSE CS-111662,MASTER ELECTRICIAN C. AERIAL FONT. 1136 MR 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED.SIGNAGE CANNOT BE HAND-WRITTEN. SITE PLACARD 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. JOB NO: DATE: DESIGNED BY: SHEET: 252369 8/24/2022 Z.V. PV-7A 1 -10 11 -20 21 -30 31 -40 41 -50 51 -60 SOLAREDGE OPTIMIZER CHART 1 2 3 4111111414p, . CL ESTEVAIENT:O LANDIM 56 NORTH ROAD,WEST YARMOUTH,MA 02673 4 AHJ:TOWN OF YARMOUTH(MA) UTILITY:EVERSOURCE ENERGY(WESTERN MA) PHONE:(774)368-8324 5 SYSTEM: SYSTEM SIZE(DC):16 X 400=6.400 kW A 4r • SYSTEM SIZE(AC):5.000 kW Q 240V MODULES:16 X TESLA:T400H OPTIMIZERS:16 X SOLAREDGE S440 INVERTER:SOLAREDGE SE5000H-US[SI1] 6 7 REVISIONS *A4******* NO. REVISED BY DATE 8 - 9 tirl _ . L ( . .'Inn FREEDOM FOREVER LLC 135 ROBERT TREAT PAINE DR.,TAUNTON, MA 02780 Tel:(800)385-1075 1 O '�I GREG ALBRIGHT Nei ii.k,li PIA CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISOR LICENSE CS-111662;MASTER ELECTRICIAN ' 1136 MR OPTIMIZER CHART JOB NO: DATE: DESIGNED BY: SHEET: 252369 8/24/2022 Z.V. PV-8 SAFETY PLAN MARK UP KEY INSTRUCTIONS: OP PERMANENT ANCHOR 1. USE SYMBOLS IN KEY TO MARK UP THIS SHEET. q- e.O OT TEMPORARY ANCHOR 2. SAFETY PLAN MUST BE MARKED BEFORE JOB STARTS AS PART OF THE PRE-PLAN o4Z- IL INSTALLER LADDER 3. DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE &MAKE NOTES ON THE JHA SHEET • B JUNCTION / COMBINER BOX IN CASE OF EMERGENCY S STUB-OUT INJURY HOTLINE X SKYLIGHT (855)400-7233 l‘i4r;$ NO LADDER ACCESS (STEEP NEAREST HOSPITAL OR OCCUPATIONAL/INDUSTRIAL CLINIC GRADE OR GROUND LEVEL *$ OBSTRUCTIONS) NAME: ESTEVAOCLIENT: LANDIM RESTRICTED ACCESS 02 703RTH ROAD,WESTYARMOUTH,MA ADDRESS: AHJ:TOWN OF YARMOUTH(MA) UTILITY:EVERSOURCE ENERGY(WESTERN CONDUIT MA) PHONE:(774)368-8324 SAFETY COACH CONTACT INFORMATION NAME: GAS SHUT OFF **SS SYSTEM: SYSTEM SIZE(DC):16 X 400=6.400 kW PHONE NUMBER: WATER SHUT OFF SYSTEM SIZE(AC):5.000kW@240V MODULES:16 X TESLA:T400H OPTIMIZERS:16 X SOLAREDGE S440 ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE INVERTER:SOLAREDGE SE5000H-US[SII] CDI SERVICE DROP SAFETY PLAN AND SIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR OZ POWER LINES WORKING SAFELY. NAME SIGNATURE BREAK AND WATER LOGREVISIONS NO. REVISED BY DATE THIS LOG IS TO BE FILLED OUT ANY TIME THE TEMP EXCEEDS 90 DEGREES.THE CREW LEAD AND ROOF LEAD ARE RESPONSIBLE FOR ENSURING THIS IS - - - COMPLETED AND UPLOADED AT THE END OF EVERYDAY WHEN TEMPS EXCEED 90 DEGREES - - - r. dan NAME 0800HRS 0900HRS 1000HRS 1100HRS 1200HRS 1300HRS 1400HRS 1500HRS 1600HRS � � voaevER ER FREEDOM FOREVER LLC 135 ROBERT TREAT PAINE DR..TAUNTON, MA 02780 Tel:(800)385-1075 GREG AL fB/RIGHT M1 CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-Al;CONSTRUCTION SUPERVISOR LICENSE CS-111662;MASTER ELECTRICIAN 1136 MR DATE: TIME: SAFETY PLAN JOB NO: DATE: DESIGNED BY: SHEET: 252369 8/24/2022 Z.V. PV-9 JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture Ladder Access • Crew leader responsible for communication with the client: Heat Related Illness Prevention NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE • Ladders must be inspected before each use. • Employees shall have access to potable drinking water that is (add as many as necessary by using additional sheets) • Extension ladders must be set up on a firm and level surface at • Client and public is excluded from work area by barricades(N/A, fresh, pure,and suitably cool.The water shall be located as a 4-to-1 rise to run angle(or 75 degrees)and the top must be Yes, No): close as practicable to the areas where employees are working. Define the Hazard: Method/steps to prevent incident: secured to the structure.Extension style ladders placed on Water shall be supplied in sufficient quantity at the beginning of uneven,loose or slippery surfaces must additionally have the Training and Pre-Job Safety Briefing the work shift to provide at least one quart per employee per base firmly anchored or lashed so the base will not slip out. • All employees onsite shall be made aware of the specific hazards hour for drinking for the entire shift.Employees may begin the • Extension ladders must be used with walk-through devices or of this project and review this HJA during a pre-job briefing,and shift with smaller quantities of water if they identify the location Define the Hazard: Method/steps to prevent incident: the ladder must extend 36"above the stepping off point. their signature indicates awareness of site conditions and the and have effective means for replenishment during the shift to • A-frame ladders must only be climbed with the ladder spreader plan to eliminate any hazards identified prior to and during the allow employees to drink on quart or more per hour.The bars locked in the open position;A-frame ladders shall not be project. frequent drinking of water shall be encouraged. climbed while in the closed position(ex,closed and used while • Shade shall be present when temperature exceeds 80 degrees leaned against a structure). • Crew leader(name/title): Fahrenheit.When the outdoor temperature in the work exceeds Define the Hazard: Method/steps to prevent incident: • Additional notes: 80 degrees Fahrenheit,employees shall have and maintain one • Crew member(name/title): or more areas with shade at all times. Mobile Equipment • New employees must be acclimatized.New employees will be • Only Qualified operators will operate equipment;operators must • Crew member(name/title): monitored by their Crew Leader(site supervisor)for the first two maintain a certification on their person for the equipment being (2)weeks of employment or longer when necessary. Define the Hazard: Method/steps to prevent incident: operated. • Crew member(name/title): • Employees will be allowed and encouraged to implement • Type(s)of mobile equipment(Type/Make/Model): scheduled breaks during each shift.Employees must take • Crew member(name/title): cool-down breaks in the shade any time they feel the need to do • Qualified operator(s): so to protect them from overheating.Supervisors are • Crew member(name/title): REQUIRED to allow employees any break period they need Material Handling and Storage during high heat conditions. CLIENT: ESTEVAO LANDIM • Materials will be staged/stored in a way that does not present a Airborne Contaminants: • Cool Vests are encouraged for all employees at all times during 56 NORTH ROAD,WEST YARMOUTH,MA hazard to client,personnel or public. Materials stored on the • Asbestos-containing(Transite)piping(ACP)-Do not disturb periods of high heat. 02673 roof will be physically protect from failingor slidingoff. (move,drill,cut fracture,etc.) • Identifythe location of the closet Occupational/Industrial Clinic UTIL TOWN R YARMOUTH(NIA) P Y Y P UTILITY:EVERSOURCE ENERGY(WESTERN • Asbestos-containing thermal insulation(ACI)and or Hospital in case a crew member becomes ill. MA) Fall Protection Asbestos-containing duct wrapping(ACW)-do not disturb, no PHONE:(774)368-8324 • A site-specific plan for fall prevention and protection is required attic orcrawlspace access is allowed if work to be performed What is the specific plan to provide and replenish sufficient water for prior to starting work and must remain onsite at all times until could cause exposure to personnel,client or public. all employees on site? work is complete;a fall rescue plan must be outlined and • If offsite replenish is necessary,where will you go to replenish discussed among the crew prior to work start. • If yes,list specific tasks and protection in place: water(location/address): SYSTEM: SYSTEM SIZE(DC):16 X 400=6.400 kW • First-person-Up(FPU)must install their anchor and connect SYSTEM SIZE(AC):5.000 kW @ 240V before any other task,including installing other anchors.The • Who will replenish the drinking water(name): MODULES:16 XTESLA:T400H OPTIS440 Last-Person-Down(LPD)must be the onlyperson on a roof INVERTER: 16 X EDGESOLAE S00GE H-U INVERTER:SOLAREDGE SE5000H-US[SIt] uninstalling fall protection. • FPCP(name and title): Restroom facilities • Employees shall have access to restroom facilities with FPU and LPD(name and title): hand-washing stations. Use of onsite restroom is at the client's discretion(location is annotated below). If client does not give Electrical Safety permission, location of suitable restroom facilities with • The Electrical Qualified Person(EQP)is required onsite to hand-washing stations offsite will be provided.The onsite perform electrical work. supervisor will identify location and make arrangements to • All electrical work will be performed with equipment in an ensure all employees have access at any point. electrically safe condition (de-energized)unless approval has • Restroom facilities will be(circle one):Onsite-Offsite REVISIONS NO. REVISED BY DATE been granted prior to work. Weather and Environment • If Offsite,add location name and address: _ _ • Service drops and overhead electrical hazards will be indentified • The site supervisor shall forecast the weather conditions at the _ _ _ and protected from contact,as neccessary. job site, prior to crew arrival,in order to mitigate any hazards Incident Reporting Procedure - - - • EQP(name and tile): associated with inclement weather(heat,cold,wind, rain,etc.) • Contact your Site Supervisor 0. • The site supervisor will utilized a portable wind meter Name: ;;� �� Public Protection (anemometer)to verify actual onsite wind conditions,by checking _ FOREVER • The safety of the Client and Public must be maintained at all at the ground and on any elevated work surface(ex, rooftop) Phone: FREEDOM FOREVER LLC times. prior to work start,at midday and prior to solar panel staging on a 135 ROBERT TREAT PAINE DR.,TAUNTON, MA 02780 • The Client and the Public shall be prevented from entering the roof. • Contact your Manager Tel:(800)385-1075 work zone through the use of barriers and/or signage,as • Elevated work involving the moving or maneuvering of solar Name: GREG ALBRIGHT required. panels shall cease at 25mph(sustained wind)until wind • Company, Client and Public property shall be protected from subsides. Phone: khk— falling objects. • Forecasted weather maximum temp(degrees f): /�h�' )(� • Pets(including dogs)shall be secured by their owners prior to • Contact your Site Supervisor CONTRACTOR LICENSE: work start. Name: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE • The Client should not leave pets,family members,or others in 902-EL-A7;CONSTRUCTION SUPERVISOR charge or care of Employees,Contractors,or Temporary Phone: LICENSE CS-111662;MASTER ELECTRICIAN 1136 MR Workers. With:Your full name, phone number,office location,brief description . SAFETY PLAN of what happen and when. JOB NO: DATE: DESIGNED BY: SHEET: 252369 8/24/2022 Z.V. PV-10 • . . . Tesla Module Specifications Electrical Characteristics .------ --- T395H 7400H T405H T395H, T400H, and T405H :it ? ! ! II ( il,h11 'tiq dlill Hilil ::I'llii 1.111 .-• ,:.(...., ,...,...,:, ' q t illidrindi 'i.0111111"H Maximum Power 1 Um?, He inadult. is one of the most pcp-miful Ii111111,1111; reshjyrit a;photovoltaic modules midilable. Our system require',up to 20.9 imrcent fe\or modulos toas,Imeve ik1,-.2.',..,111'.' novor os a shand.,-dd 111111111111 . NruCT 1 ' I sythru.The riod Ale bo,ttsts, d ihgh conversio.-1 ;10111111 1 i , 1 xfficioncy old a had-ccli err toe 1 tectare thc,t mph uses I Temperature Rating(STC) Mechanical Loading shdde toleronce. H11111111111. L li , 6 ii1 11 11 . 1.-6..i moi riphilt pip Beautiful Solar 01111111111 ! : l ' i-lez:tur:ng°Jr proprietary Zup C.i,00yo dorpon, 1111111 11 11 !1111 ;i I II ! the all-black mociu:e connects eosily with Tea 7. sl8 i . .-; '' I . i compenIm onts to eo panets close to your 111 1111 1 ' Hil 111 1 1111 '1 ' Mechanical Parameters ruof and close to each oti-icr for a tedoudedaesthetic —--- i .xath simple otop-in and precision ouarter-turn 111111111111 ,111111 1111, 11 6,,ip.-, tI- connections. , 1111111111111 11111111111111 iiim hP, ' Reliability 11.11111111ffiiiIMH Lw msld triodules ore surged t automotisc-gradu HOoloilLi.,.. J ngin:yr: nni de °scrutian :d d uality assurore c . ''' ' ' ' Mimi ii . . for exccoding industry standaids. 111111111i iiiil 1 ': Modulos are certified to IEC„/UL 61730- I, ' 111111111; ' 2 r t xr ip r.6 x !EC,/UL 61730 -2 anci 1EC G1215. ., • .1, . 1 i i .. ,1111111g. H .... i., .... .. Operation Parameters ,.._,.: 1- ,p• .r, 2 It '--k. Limited Warranty Linear Power Warranty Materials and Processing 28 years '''''. Extra Linear. Power Output 25 years At least 98%of nominal poorer during first year. . -------7----..-- I: Thereafter max.0.5%degradation per year.At. least 93.5 %of nominal power up to 10 years.At Lust 86 ,ii..of notional pourer up to 25 years. r - '.... I, orp', ',.:......V=11-21, I Power Optimizer -0 For North America Power Optimizer Q S440, 5500 x S440 `' S500 � '"°. Unit„� For North America INPUT Fated Input DC Power 440 I 500 W Abso;ute Maximum Input Voltage(Vdc) 60 Vdc 5440 5500 MDPT Operating Range 8-60 Vdc 2 Maximum Short Cecua Current(Isc)of Connected PV Modc',e 14.5 15 Aoc .- -- X Maximum E`f,cency I 98.6 j Weighed Efficiency 98.6 % "� Overvoltage Category II r' '1� , OUTPUT DURING OPERATION Q Maximum Output Current 15 Ado •����`} ) Maximum Output Voltage 60 I Vdc "rj'�' `�" rir OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1+/-0.1 Vdc STANDARD COMPLIANCE '` IMMI Photovoltaic Rapid Shutdown System NEC 2014,2017&2020 EMC FCC Part 15 Class B.IEC61000-6-2,IEC61000-6-3 l._ �� O Safety -- ----- �- -- IEC62109 1(class II sa`ety),UL1741 —� ! Material U_94 V-0,UV Res Stant Rolls Yes i c Fire Safety VDE-AR-E 2100-712 203-05 ,i111 I I /' MIIMIEll INSTALLATION SPECIFICATIONS INI MaximumAliowed System Voltage 1300 Vdc f amens ons(W x L x H) I 129 x 153 x 30/507 x 6.02 xi-,8 i mm/in Weight(heading caUes) 655/1S gr/lb 'e' Input Connector MC4s ( 77° Input Wire Length 0.1/0-32 m/B O,,p,.t Connector VC4 Length Output Wire Lg p � (*)23,00-0/(-)754,(-)032 m/h Operating Temperature Range' -4C to+85 'C Protection Rating IP68/Type6B Relative Humidity 0-100 tO Pared powe'of toe income at SIC w,II no:exceed the power cpo mzer Ra,ed lnpct DC Power.Noddies wdh L a to+5%power La e`ance a,e a''.owed (2)Fe-other connector types please contact SolarEcge (3)Fe'a-Ment temperature above-70'C/-158°F power de-rating is applied.Re-er to Powe'Optimizers Temperature De-Raing Technical Nae'or more details PV System Design Using a SolarEdge Single Phase Three Phase for 208V Three Phase for Inverter HD-Wave grid 277/480V grid PV power optimization at the module level Minimum String Length 5440,5500 8 14 I 18 (Power Optimizers) I Maximum Stung Length(Power Optimizers) 25 I 50°' Maximum Nominal Power per String 5700(6000 w.th SE7600-US-SE1'.400-U)I 6000 1 - 12750 W / Specifically designed to work with SolarEdge / Faster installations with simplified cable management I 1 I residential inverters and easy assembly using a single bolt Maximum Allowed Connected Power per String 1One String 7200W (Permitted only when the difference in connected power oetweeo Refer to Footnote 5 15,000W strings is 1,000W or less) Two stn ngs or more 78COW / Detects abnormal PV connector behavior, / Flexible system design for maximum space utilization Parole s r gs dr Di ergntlengms oro e to ions V preventing potential safetyissues* t4)A s.ng wth more roan 30 optimizers does not meet NEC rapid sbutdewn equre ehs,safety votage i be above ire 30V•eq,remeet p g (5)if the Inverters ra ed AC power c maximum nominal power per stn rg,then.he maximum power per s.r rg will be able to reach up to the inverters maximum input DC power Refer to:https//www soizredgecum/ sites/defaulVfi es/se-power-optimizer-singie-string-design-application-nute.pd` I Compatible with bifacial PV modules lb)Itis not allowed to mix 5 series and P series Power Optimizers it new installa[las / Module-level voltage shutdown for installer and / 's firefighter safety c, `, / Meets NEC requirements for arc fault protection(AFC') t and Photovoltaic Rapid Shutdown System(PVRSS) ';',,,� \\v/ ----- . j:-.1 .___ _ -- EL I Superior efficiency(99.5%) Z ♦f "--- /...) I AS / Mitigates all types of module mismatch loss, /,`i' from manufacturing tolerance to partial shading t' ' ' P .s r, ' ,i F � o xxc:eo ava+aDi dy In 2022 rzz/ li' _ LL. solaredge.corn SO l a r o f f .‘,0'' (/�..,...,,,.,„'y./.. SolarEdge Technologies,Inc AO rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOIAREDGE are trademarks or registered trademarks of SolarEdge Technologes, c ,,./us Ro H S Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date Feoruay8 2022 DS-000018-NA.Subject to change without notice. ``"'M�MMMMs Intertek ©2016 Eaton. All rights reserved. pe.eaton.com Eaton general duty cartridge Y fuse safety switch dr'� DG222NRB • UPC:782113144221 Dimensions: • Height: 14.37 IN • Length: 7.35 IN • Width: 8.4 IN Weight:10 LB Notes:Maximum hp ratings apply only when dual element fuses are used. 3-Phase hp rating shown is a grounded B phase rating, UL listed. Warranties: • Eaton Selling Policy 25-000, one (1)year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: • Type: General duty, cartridge fused • Amperage Rating: 60A • Enclosure: NEMA 3R • Enclosure Material: Painted galvanized steel • Fuse Class Provision: Class H fuses • Fuse Configuration: Fusible with neutral • Number Of Poles: Two-pole • Number Of Wires: Three-wire • Product Category: General duty safety switch • Voltage Rating: 240V Supporting documents: • Eatons Volume 2-Commercial Distribution • Eaton Specification Sheet- DG222NRB Certifications: • UL Listed Product compliance: No Data h <0k-- Ec I Fasten. ,,, ,.. , ROCKIT` ,„ For Installers. By Installers. ' —may COJDLINI r---- The fast installing Rocklt Coupling �r �, ,it t � -+ easily attaches to the module frame " <- , � 'a•c' �° `. - to bridge the gaps between modules. ," l ,. r The sleek black Skirt installs first and acts r _ as an alignment guide for the entire array. 6 The Skirt End Cap does double duty as a .. ...,.. skirt coupling device and an aesthetically- - �� pleasing finishing touch. ---�—"�— ROCKT MOJ ��T ..—----- ' '" Featuring integrated bonding pins, the Rocklt t art _ Mount connects to the Slide and can easily be . ,,. ::„..,. "' : u positioned for fast installation. Features top- es T _ LL___RaCKIT i ; - down leveling. 1 , �"^', 1 E COMPLETE RAIL-LESS RACKING SYSTEM aL ti' The Rocklt system is the industry's premier rail-less if, .` PV racking system for composition shingle, tile, and ., metal roofs. Designed in conjunction with the needs of Composition Shingle, — m.. installers, Rocklt quickly& easily installs with a single tool. :e Tile,Metal Featuring an easy-to-position alignment slide and a top- t `` down leveling system, Rocklt is logistically intelligent with t `j f no need to ship or transport long rails. Components are fILI:1,74 a®caa Rail-Less �. ti available in a black finish that complements both commercial '" and residential applications. Conforms to UL 2703. oPStructural-Attach • Patented watertight technology Direct-Attach • Fully integrated bonding i " ` • Top-down leveling system R O C K I T SLIDE • North-South adjustability A Available in three variations, the Rocklt ` �,. • Single tool install -', ---z. a � , ' "-"" ; Slide allows installation on composition F,41,,,,, i 25 YEAR WARRANTY shingle, tile, and metal roofs. F :RANI , Ipvl� L D F lvi 0 U N T STREAMLINED INSTALLATION WITH Attaches and fully bonds MLPE's (Module MINIMAL ROOF PENETRATIONS �.„” revel Power Electronics)to the module frame ' with a single bolt clip. V . ECOFASTENSOLAR COM S structural ENGINEERS July 5,2022 EcoFasten Solar LLC 4141 W Van Buren St,Ste 2 Phoenix,AZ 85009 TEL:(877)859-3947 Attn.: Eco Fasten Solar LLC-Engineering Department Re:Report#2015-05884HG.07.01—EcoFasten-Rocklt System for Gable and Hip Roofs Subject: Engineering Certification for the State of Massachusetts PZSE,Inc.—Structural Engineers has provided engineering and span tables for the EcoFasten- Rocklt System,as presented in PZSE Report#2015-05884HG.07.01,"Engineering Certification for the EcoFasten-Rocklt System for Gable and Hip Roofs". All information,data,and analysis therein are based on,and comply with,the following building codes and typical specifications: Building Codes: 1. ASCE/SEI 7-10&7-16 Minimum Design Loads for Buildings and Other Structures, by American Society of Civil Engineers 2. 2012,2015,&2018 International Building Code 3. 2012,2015,&2018 International Residential Code 4. AC428,Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV)Panels, November 1,2012 by ICC-ES 5. Aluminum Design Manual 2010&2018, by The Aluminum Association, Inc. 6. ANSI/AWC NDS-2015&2018,National Design Specification for Wood Construction,by the American Wood Council Design Criteria: Risk Category II Seismic Design Category=A-E Exposure Category=B,C& D Basic Wind Speed(ultimate)per ASCE 7-16=90 mph to 180 mph Ground Snow Load=0 to 60(psf) DIGITALLY SEALED This letter certifies that the loading criteria and design basis for the °H .1%OF EcoFasten-Rocklt System Span Tables are „ PAUL K. otic in compliance with the above codes. ZACHER �, TRUCTURAL If you have any questions on the above,do not hesitate to call. �o� isTe \���, `SS/ONALENG Prepared by: PZSE,Inc.—Structural Engineers Roseville,CA 1478 Stone Point Drive,Suite 190, Roseville,CA 95661 1916.961.3960 916.961.3965 www.pzse.com