Loading...
HomeMy WebLinkAboutBLDE-22-000951 PLANS MOUNT SYSTEM t . . F, HOTOVOLTAIC ROOF 12 MODULES-ROOF MOUNTED - 3.60 kWDC, 3.8 kWAC 2 STILES RD, S YARMOUTH, MA 02664 USA SYSTEM SUMMARY: GOVERNING CODES: SYSTEM SIZE(DC) :STC: 12 X 300=3600.00W DC THIS PROJECT COMPLIES WITH THE FOLLOWING: 2015 INTERNATIONAL BUILDING CODE(IBC) : PTC: 12 X 271.4=3256.80W DC 2015 INTERNATIONAL RESIDENTIAL CODE(IRC) SYSTEM SIZE(AC) : 3800W AC 2018 INTERNATIONAL MECHANICAL CODE(IMC) .,; . .. . . 2018 INTERNATIONAL BING CODE(IPC) MODULES : 12 X HYUNDAI SOLAR HID-S300RG(BK)(300W) 2018 INTERNATIONAL FUELIGAS CODE(IGC) PROJECT SITE ^ F u€v x 2018 INTERNATIONAL ENERGY CONSERVATION CODE(IECC) FREEDOM FOREVER MA OPTIMIZERS : 12 X SOLAREDGE P320 135 ROBERT TREAT PAINE DR. 2015 INTERNATIONAL EXISTING BUILDING CODE(IEBC) #1, TAUTON,MA 02780 INVERTER :SOLAR EDGE SE3800H-US 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE(ISPSC) '" ,,, TEL(800)385-1 075 ROOF :COMP SHINGLE 2020 NATIONAL ELECTRICAL CODE(NEC) `' I. VERSION TILT 30°PITCH AS ADOPTED BY TOWN OF YARMOUTH ups Fa`a Y DESCRIPTIONDATE REV AZIMUTH : 126° CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE INITIAL RELEASE 08-13-2021 UR REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY RAFTER/TRUSS SIZE :2"X4"RAFTERS @ 20"O.C. FIELD CONDITIONS. ATTACHMENT TYPE : UNIRAC SFM INFINITY ELECTRICAL MAIN SERVICE PANEL : (E) 100A MSP WITH (E) 100A ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE t� Yy r,,.,0 , CONTRACTOR NO: HOME IMPROVEMENT CONTRACTOR MAIN BREAKER ON END FEED MAXIMUM EXTENT POSSIBLE. lsaoao CONSTRUCTION SUPERVISOR LICENSE INTERCONNECTION : PV BREAKER TIE IN MSP ( '` p cs-111662 OCPD RATING :20 AMPS 4 ,�c rn-m Ru, SOu I BUSINES LICENSE 2LEL-AITRACTOR INSTALLATION NOTES: +, YaYarn-mull', MA 0266 �... MASTER ELECTRICIAN 1136 MR • PV WIRE SHALL BE USED ON DC RUNS FOR UTILITY : EVERSOURCE ENERGY UNGROUNDED/TRANSFORMERLESS INVERTERS. 1 JOB ID:F095368 q.: PROJECT NAME N• INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WEATHER LOADING: WORK. �,;,s WIND SPEED :140MPH • EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS """" "` • DIG ALERT TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SITE LOCATION: ci) F— GROUND SNOW LOAD :30PSF SAFETY PRIOR TO ANY EXCAVATION TAKING PLACE 0 j C o O rir,,,,,tri.:"'"4: ',..„77',,, ,,,,:.,. ; ''''': ; 1 ARRAY LOCATION 3 :ILII 72: Q :(:)Qj !Q r—, LL 0 .����' �\ � `: gyp° �' ii. -�"4` L � i' � � � O i 2ADDAGA \ � a I LL N 0 0 l " CO Z F i x TABLE OF CONTENTS GJ�cb �© y ' , . .r ,.PV-1 SITE LOCATION AND HOUSE AERIAL VIEW \ .� G�StC � ` 'a PV-2 SITE PLAN jee AL /ii ' ' CO(� — (13 4 SHEET PV-2A ROOF PLAN WITH MODULES LAYOUT 1 4 1 /f� PV-3 ROOF MOUNTING DETAILS 13-AUG-2021 1 w a#. ' SITE LOCATIONAND HOUSE AERIAL VIEW I ELECTRICAL LINE PV-5 NOTES AND EQUIPMENTI PV-4 �LIST 7 SHEET SIZE PV-6 LABELS ANSI B PV-7 OPTIMIZER CHART r f" PV-8 SAFETY PLAN SHEET NUMBER HOUSE AERIAL VIEW: PV-1 PV-9 JOB HAZARD ANALYSIS • ROOF AREA: 1915.70 SQ FT (N)JUNCTION BOX ROOF DESCRIPTION (N)SOLAR EDGE SE3800H-US INVERTER ROOF TYPE COMP SHINGLE ROOF (N)MA SMART PRODUCTION METER B ROOF RAFTERS RAFTERS (N)30A NON FUSED AC DISCONNECT ROOF TILT AZIMUTH SIZE SPACING (SQUARE D DU221 RB) S1 1 CE PANEL #1 30° 126° 2"x4" 20"O.C. — —_ . — . (WITH E) O(E) 100A MAINA MAIN Z BREAKER ' — �: (E)UTILITY METER • —107.80 i — • ' • - i • ;. \ . . .11're e d 0 Mr r----6-..' 6 % ENLARGED VIEW FREEDOM FOREVER MA 1' �/` 1 —_._------- --------_ - _.. 135 ROBET TREAT AUTON,MA 02780 DR. 1 (b TEL (800)385-1075 / VERSION • V `r— I ATE REV 1 1 :^ INITIAL RELEASE 08-13-2021 UR 1•_ U ) DESCRIPTION - I • �0 I 1 z c9 1 OJ 1 ELECTRICAL 1 e O � � 1 N Q CONTRACTOR NO: HOME IMPROVEMENT CONTRACTOR �\ Q- ��' `, , w+7e 198080 \CO 1� (//,‘ 3,,a CONSTRUCTION SUPERVISOR LICENSE u °� CS•111662 I• \ 1 a n d In����7�7 BUSINESS ELECTRICAL CONTRACTOR 1 \ Q'��QL U LICENSE 902-EL-Al PROPERTY — Q ��/p�D \ MASTER ELECTRICIAN 1136 MR !� e✓o ( 0 0 I JOB ID:F095368 i 1E TREE(TYP.) GJa �0�3 I 1` J 1� �� o p l9 PROJECT NAME ROOF#1 1 _ 1 \ ee Q (12)HYUNDAI SOLAR I 22� • , i �.I AL " " g O = HID S300RG(BK)(300W)MODULES9'' — t O ~r— Ai O ♦ I 13-AUG-2021 J co 0 v, CO . I W _ co Li 2 1 1 ` , 1 <I Q N O co �I ti �� �4 U (.2 § O } SEE ENLARGED VIEW - 1 — — —I LEGEND . . I_I_ O I / �UM I -UTILITY METER >- j _ CO IMSo MAIN SERVICE PANEL Q O ' 0 Cs /� m C�4J �ACDI -AC DISCONNECT N Q / IINvi -INVERTER z f- 1 r JB -JUNCTION BOX Q Cl" 'i I — — IPVMl -SMART PRODUCTION U) Q Q 1 — � — — i METER . ... — i — — X -CHIMNEY SHEET NAME L - �� —84.91' -VENT,ATTIC FAN SITE PLAN (ROOF OBSTRUCTION) 5T 1 �� RD —ROOF ATTACHMENT E ANSIIZ L -CONDUIT SHEET SB PLANA41 -GATE 1 1° X 17" SITE -FENCE SHEET NUMBER SCALE:1/16 V-0" gv PV-2 a )ROOF AREA: 1915170 SQ FT ROOF DESCRIPTION ROOF TYPE COMP SHINGLE ROOF ROOF ROOF AZIMUTH RAFTERS RAFTERS TILT SIZE SPACING #1 30° 126° 2"x4" 20"O.C. ARRAY AREA A& ROOF AREA CALC'S #OF ARRAY ROOF ROOF ROOF AREA AREA 1 AREA MODULES (Sq.Ft.) (Sq.Ft.) COVERED BY p . Aag� €��,� .t3 w ARRAY /o G e t J ti #1 12 216.54 521.14 41.55FORivik O FREEDOM FOREVER MA 135 ROBERT TREAT PAINE DR. TAUTON,MA 02780 TEL:(800)385-1075 VERSION DESCRIPTION DATE REV INITIAL RELEASE 08-13-2021 UR ELECTRICAL \ \4\\\\14't CONTRACTOR NO: \II HOME IMPROVEMENT CONTRACTOR � �q,S ` 36•. \ S� \\\ �\ \\ ���6` 98080 CONSTRUCTIONSUPERVISORLICENSE �@�n/� , V A,y A V CS-111662 // �D�D�L=dIIU"11 T BUSINESS ELECTRICAL 1�� n M o p A\�� A V /�.� V CONTRACTOR L�1W LICENSE 902-EL-Al 1011 �o�n�� 1 1 P l �y \\,\ WO � ��� : I MASTER ELECTRICIAN 1136 MR 1A 1 JOB ID:F095368 % DZ )ps ��C�D�� �o� Q� PROJECT NAME i 0jALF ° ����' C‘; Q 13-AUG-2021 \• - - A 1A 00 \ co 2 ,1\`,� i W Q o No J O Ct zEt Q ROOF#1 V ,/- 0 }- \\4\N### \ (12)HYUNDAI SOLAR w O u_ ���,��� :b HID S300RG(BK)(300W)MODULES J m Q A !\ 36., , 1--- N. z ,(- LEGEND D o ,F T 1 N O O ‘,0,,,i,ti I um' -UTILITY METER Q 0 ® qy\1\\`1�, 'r iMSPI -MAIN SERVICE PANEL . m fl Z 2 It ~ 6 --- (N)JUNCTION BOX IACD] -AC DISCONNECT < <il = ® s cr. I INv I -INVERTER Cl) JB I -JUNCTION BOX SHEET NAME IPVMI -SMART PRODUCTION ROOF PLAN WITH 'NOTES: 1 -- (N)SOLAR EDGE SE3800H-US INVERTER METER MODULES LAYOUT 1.EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS 2.ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE (N)MA SMART PRODUCTION METER XCHIMNEY - 'CENTER OF THE MODULES - (N)30A NON FUSED AC DISCONNECT 1SHEET SIZE 13.JUNCTION BOX IS MOUNTED TO THE RAIL. (SQUARE D DU221RB) I O - VENT,ATTIC FAN (ROOF OBSTRUCTION) ANSI B -- ----- - -- iI� ROOF PLAN WITH MODULES LAYOUT (E) 100A MAIN SERVICE PANEL ' 1 1FFX17° WITH(E) 100A MAIN BREAKER -CONDUIT SHEET NUMBER SCALE: 1/8" = F-0° A ---- (E)UTILITY METER -FIRE PATHWAY PV-2A . . ' UNIRAC TRIMRAIL ROOF#1 ' . , PV MODULE , -e• , , — 7 111=1.11 , — i ... . (----, , 2.5" UNIRAC SLIDERS AND . , ... ,,--.." .,_ _ - - , , . • V fre GI C.,),]0 MI- ( , T ,,.... TRIMRAIL ROOF ATTACHMENTS ' 177--- GOi(Vf; (E) ROOF MEMBRANE FREEDOM FOREVER MA 135 ROBERT TREAT PAINE DR TAUTON,MA 02780 i--; 25MINFLASHING TEL (800)385-1075 . " . FL i , ----- _ EMBEDMENT il — _. 1, __ — _ VERSION DESCRIPTION DATE REV 5/16" STAINLESS STEEL LAG BOLT , LA_ WITH 2AND FLAT WASHER-1/2" MIN. EMBEDMENT , _ ......11114 .... INITIAL RELEASE 08-13-2021 UR . .. ' -.o - - - -- -- (E) BUILDING ' . . ' , ' , , i , ELECTRICAL STRUCTURE 1 CONTRACTOR NO: HOME IMPROVEMENT CONTRACTOR 198080 CONSTRUCTION SUPERVISOR LICENSE CS-111662 - BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-Al MASTER ELECTRICIAN 1136 MR 0-1'14 "PrelF [1:-7-- JOB ID:F095368 SFM TRIMRAIL ..,T,t , \ PROJECT NAME /• '''S-\ i 1 o COM MAX ATTACHMENT SPAN 4' STAGGERED D 2 PV MODULE , \ \ [Ca6Z2a0 . /1/ . 1- AIM" 'IIIIIIPA j-qtAL 91 1 5FM Component5 , -4 •„-q -A 1 5.: N, (E) ROOF 13-AUG-2021 1 2— Wai 2 c) u_ . . , 1 / I— MEMBRANE i .- DIM td 1:-.S.:11;A 1' —1 --- co 0 >: 1" g.) Z 4..."...L. i C '''. 7,7, 7.. r..:,A :.ii-4'1 -:Od'..-'-..:. r-— Ct (I) D cp rI c‘i 0 Q a L i il ct ffell SF:A Att,..: Z z.r.Lci M 2 It 1— 2.5" MIN. f„-i c' UNIRAC SLIDERS 512.1:i.i..t' . < El EMBEDMENT 1_ V FLASHING SF-td Ifirrl (I) < I SHEET NAME 5/16" STAINLESS STEEL LAG BOLT , At'l1,11°il1 WITH 2-1/2" MIN. EMBEDMENT 1 MOUNTING DETAIL AND FLAT WASHER E.F l'il Mill UM ' C.1:.p SHEET SIZE (E) BUILDING STRUCTURE ANSI B 1.-LA I I an LL: I - ' - 11" X 17" SHEET NUMBER CUL ROOF MOUNTING DETAILS _:.. - -?':_'-.4f. 1 ,_ _ ; i ii 11 SL,Ltilii i PV-3 SCALE: NTS. fl (12) I-I'YU`NDAI SOLAR HID-S300RG(BK)(300W) MODULES CONDUCTOR AMPACITY DE-RATE CALCULATION 1 (12)SOLAREDGE P320 POWER OPTIMIZERS �4�A`jNOFMASs9c, ND Ro MEIHODE yGN II LOCATION WIRE LOCATION CO UCTO CONDUCTOR' 310.15(B)(16) NEC FACTORS TABLE ADJ. MAE ELECTRICAL 01 STRINGS OF 12 MODULES CONNECTED IN SERIES PER STRING CIRCUIT NEC FACTORS TABLE O( )O CONDUCTOR CONDUIT 3OND(B(3)O g N ( ) QUANTITY TEMPERATURE AMPACITY @ NO.53873 310.15 B 2 a AMBIENT SIZE ALLOWABLE CORRECTION 90°C SYSTEM SIZE:- 12 x 300W= 3.60 kWDC CORRECTION PER A o �o /� �� 'SYSTEM SIZE:-01 x 3800W= 3.8 kWAC ARRAY TO JUNCTION BOX ROOF/FREE-AIR 2 10 40 1.00 40.00 1.00 FFSS/ONAIi-vr"- JUNCTION BOX TO INVERTER WALL 2 10 40 1.00 40.00 1.00 Exp:6/30/2022 INVERTER TO AC DISCONNECT WALL 3 10 40 1.00 40.00 1.00 AC DISCONNECT TO POI WALL 3 10 40 1.00 40.00 1.00 f( FREEDOM FOREVER MA 135 ROBERT TREAT PAINE DR. -- ---- --- TAUTON,MA 02780 (E)UTILITY METER', TEL:(800)385-1075 vV VERSION DESCRIPTION DATE REV 3/4"EMT CONDUIT r '.1 INITIAL RELEASE 08-13-2021 UR (1)#10 AWG THWN-2+RED L (1)#10 AWG THWN-2-BLACK / (12) MODULES IN STRING#1 (1)#10 THWN-2 GND ._ r (N)AC DISCONNECT 30A ELECTRICAL (N)SOLAR EDGE SE3800H-US(240V) NON-FUSED,VISIBLE CONTRACTOR NO: #12 #2 #1 OUTPUT:16A,240 VAC, (N)MA SMART LOCKABLE LABELED SQUARE D DU221RB) (E)MAINA SERVICE PANEL, HOME IMPROVEMENT CONTRACTOR 100A RATED,120/240V 198080 CONSTRUCTION SUPERVISOR LICENSE (N)JUNCTION100A PRODUCTION METER DISCONNECT,240 VAC INTEGRATED DC DISCONNECT (_- ) NEMA 3R,UL LISTED,INTERNAL FDI WITH 1,_______ CS-111662 ) ( '. BUSINESS ELECTRICAL CONTRACTOR I- BOX - -� n LINE. _l—^I - �/ LICENSE 902-EL-Al /+ ___._ ✓-�+ + Q DC _ - ^ (E)MAIN BREAKER MASTER ELECTRICIAN 1136 MR ' O m m . 100AI2P,240V J ��� o ! ^• ._� JOB ID:F095368 ACN 8 //// \ N N ; ( °- I L2 L2 ii PROJECT NAME L ---- - -CH --Z\-_,2-- _ ' --- v I G v 20A/2P BREAKER PV O Y I I o LOAD (1)#10 AWG PV WIRE+RED --------� I 0 � J CSso D O (1)#10 AWG PV WIRE-BLACK (1)#6 BARE CU GND _- - _ -- - I f----- LU .. co ..I 7 r J T< 0 o O Ct _..D EXISTING ..L - Q (3)#10 AWG THWN-2 - ) GROUNDING U Q SOLAREDGE P320 POWER OPTIMIZER (1)#10 AWG THWN-2 CU GND SYSTEM - (n �" RATED DC INPUT POWER-320 WATTS 3/4"EMT CONDUIT -I O MAXIMUM INPUT VOLTAGE-48 VDC } j Z C) MPPTRANGE-8TO48VDC F- MAXIMUM INPUT CURRENT-13.75 ADC rI n O MAXIMUM OUTPUT CURRENT-15 ADC STRING CV 0 O LIMITATIONS-8 TO 25 OPTIMIZERS, m 5700 WATTS STC PER STRING MAXIMUM (Y z SOLAREDGE OPTIMIZERS HAVE INTEGRATED RAPID SHUT DOWN } < I MAX DC OPTIMIZER OUTPUT CURRENT PER STRING CIRCUIT SHEET NAME ELECTRICAL LINE 15 1.25 18.75 DIAGRAM BACKFEED BREAKER SIZING MAX CONTINOUS OUTPUT CURRENT 16A @ 240V SHEET SIZE - --- _ _ - - - - -- --- ---- -- - ANSI B 16 1.25 20 20A BREAKER-OK - - SEE 705.12(B)(3)(4)OF 2020 NEC -CONNECT TO PREMISES GEC SYSTEM 11" X17" ELECTRICAL LINE DIAGRAM 100 1.20 120 NOTE: SHEET NUMBER CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED P - ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT SCALE: NTS 120 100 20A ALLOWABLE r V `i BACKFEED TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS GENERAL NOTES : S OFM1. 12 HYUNDAI SOLAR HiD-S300RG BK , 300W WIRED AND LISTED TO UL1703 STANDARDS MATERIAL LIST ANRAGU( ) ( ) ( ) - __ ------ - MANIRAGUHA QTY • EQUIPMENT DESCRIPTION (' ELECTRICAL N 2. THE SOLAR EDGE SE3800H-US INVERTER WITH INTEGRATED DC DISCONNECT AND ARC NO.53873 FAULT PROTECTION.ATTACHED WITH SYSTEM ELECTRICAL SPECIFICATIONS, GROUND FAULT OPEN CIRCUIT VOLTAGE(Voc): 40.0V .o PROTECTION &LISTED TO UL 1741 STANDARDS. HYUNDAI SOLAR MAX. POWER VOLTAGE (Vmp) : 32.5V �a,. )STEaEOG\\,�� 12 HiD-S300RG(BK), (300W) SHORT CIRCUIT CURRENT(Isc): 9.8A siDNALEN 3. PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE MAX. POWER CURRENT(Imp): 9.3A AS PER NEC SEC. 250.166(A). PTC RATING : 271.4W Exp:6/30/2022 DC MAX SYSTEM VOLTAGE : 480V 4. SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH AC OUTPUT VOLTAGE RANGE : 211-240V . REQUIREMENTS OF ART. 690 OF THE NEC. 01 SOLAR EDGE MAX.AC OUTPUT CURRENT: 16A .LiAL� (w � i�b'ii SE3800H-US MAX.AC POWER OUPUT : 3.8kW ` ° " ` 5. CONDUIT ABOVE ROOF SHALL BE NO LESS THAN 1" FROM TOP OF THE ROOF TO BOTTOM OF WEIGHTED EFFICIENCY: 99D/o FREEDOM FOREVER MA 135 ROBERT TREAT PAINE DR. RACEWAY. TABLE NEC 310.15(B)(3)(C). TAUTON,MA 02780 RATED DC INPUT POWER: 320W TEL(800)385-1075 6. PHOTOVOLTAIC DC CONDUCTORS ENTERING THE BUILDING SHALL BE INSTALLED IN SOLAREDGE P320 MAXIMUM INPUT VOLTAGE : 48VDC VERSION METALLIC RACEWAY AND SHALL BE IDENTIFIED EVERY 10 FEET--AND WITHIN 1 FOOT ABOVE 12 MPPT RANGE : 8-48VDC DESCRIPTION I DATE REV OPTIMIZERS MAX. INPUT CURRENT: 13.75ADC AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS, OR BARRIERS --WITH INITIAL RELEASE 08-13-2021 UR MINIMUM 3/8-INCH-HIGH WHITE LETTERING ON RED BACKGROUND READING: "WARNING: MAX. OUTPUT CURRENT : 15ADC --- ____ __--- -___ __ -_--_- _ PHOTOVOLTAIC POWER SOURCE 1 OCPD I 20A 1 1 JUNCTION BOX 600VDC, NEMA 3R, UL LISTED 7. SYSTEM GROUNDING ELECTRODE CONDUCTOR FOR PV SYSTEM TO BE SIZED TO MEET THE ELECTRICAL REQUIREMENTS OF NEC TABLE 250.66. 30A NON FUSED RATED, 240VAC, NEMA 3R UL CONTRACTOR NO: 1 AC DISCONNECT LISTED HOME IMPROVEMENT CONTRACTOR 198080 8. THE EXISTING MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER. CONSTRUCTION SUPERVISOR LICENSE CS-111662 60 FT CONDUIT 3/4" OR LARGER EMT CONDUIT BUSINESS ELECTRICAL CONTRACTOR 9. UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM. MASTERS ECTRiCIAN1136MR 10. TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION. BILL OF MATERIALS LEGEND: LI Base System Part ElAccessory JOB ID:F095368 PROJECT NAME 11. SOLAREDGE INVERTERS ARE LISTED TO UL 1741 AND UL 1699B STANDARDS PART SUGGESTED UNIT PRICE TOTAL LIST PRICE NUMBER PART TYPE DESCRIPTION QUANTITY QUANTITY (USD) (USD) (i) O I 12. SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY)AND UL 1741 O D 256072U 'rt-Ti SFM 1RIMRAll 72 URN URK 3 3 31.66 94.95 O STANDARDS .J ccs O r � 250120U 1 nm Spice. SFM TRIM SPLICL DRS 2 2 3.79 7.98 W N J r !_, ct O O 00420CD r.o.i A:taclrnrn: FLASIIKIT 57M TRIM COMP DARK 5 S 10.92 54-60 U r^ O } 2 LU 2 CO LI- 25.0020‘) f.1.1,1,.,I l3) SENt MICRORAI..2" 20 20 7.67 157.40J = W 0 �L�// D O z 250030U t.k.r�i;,c I;-1I SpL:c• SFM ATT SPLICES" 2 2 13.02 26.04 I,J_ N O 0 Q 2 z 0 250010U t.'::rci?a I Sr6s SEM SPLICE 6.5" 6 6 9.12 54.72 i'• n/ 0042700 RcoiA:t.chrr.c,: FLASI/KITSRM SLIDER COMP 22 22 8.63 189.86 >- < I DARK //�/� Q U) 0081000 1 .:uir,(I:,.vp SFM,TRIM BONDING CLAMP 1 1 3.73 3.73 SHEET NAME NOTES AND 2501100 CL, SFM TRIMRAILUNIVCLIP W;HDW 6 6 2.69 16.14 EQUIPMENT LIST SHEET SIZE 008009P Gta.md:n6Lsg ILSCOLAY INLUG(GBL4DBT) 1 1 6.10 6.10 ANSI B 11" X 17" COS000U N-S vr.tc Clip SFM N/S BONDING CLAMP 3 3 2.15 6.45 SHEET NUMBER 2501300 ECm'.Cats SEM TRIM END CAPS 1 1 1.07 1.07 PV-5 V-5 a c __�___a..._ A�,VSH OF MgSS 11 r� 0 METHODE y6N PHOTOVOLTAIC T,1 �11. ] U MANIRAGUHA co =.= r 31]_, i r.=' rrii;1, , r,,jTp G•: ELECTRICAL ttd , lc-uty i�lilezri� ihC. ,ley.+fi �� 'fal�e�lz":1Misf h ,titin 4r $.o91,1w4 jr4,0. NO.53873 1 w AC DISCONNECT .re «,..r of,j_i,:. , i�.�7rz 1,,I r�,,,. a>filelr� �.(,-4.1..r}_1 ,� uCy„tit: .o i1 00: 50 /STERE <"2 FFSS/ONALENG\C, LABEL 3 LABEL 11 AT EACH DISCONNECTING MEANS FOR AT EACH AC DISCONNECTING MEANS LABEL 12 Exp:6/30/2022 PHOTOVOLTAIC EQUIPMENT [IFC 605.11.3, NEC.690.15, NEC 690.13(B)] AT POINT OF INTERCONNECTION [NEC 690.17(E)] OVERCURRENT DEVICE , . [NEC 705.12(D)(7)] < zci - FOR£v E; 9 \111 — I ! CAUTION ! PHOTOVOLTAIC FREEDOM FOREVER MA 135 ROBERT TREAT PAINE DR. io AC DISCONNECT ! TAUTON.MA5107 TWO 'Ol��► ll�l. c�l �, clQ`1r PHOTOVOLTAIC SYSTEM SOURCE C C TEL:(800)385-105 VERSION �•i�ioll;('dc�E I�I�v��' �fi►'�I CIRCUIT IS BACKFED _-_--- - - OPERATING CURRENT: 16A DESCRIPTION DATE REV OPERATING VOLTAGE: 240 V INITIAL RELEASE 08-13-2021 UR LABEL 5 LABEL 6 - AT POINT OF INTERCONNECTION; LABEL, LABEL 4 - -- - - SUCH AS LABEL 5 OR LABEL 6 MUST AT POINT OF INTERCONNECTION; LABEL, AT POINT OF INTERCONNECTION, MARKED AT -- IDENTIFY PHOTOVOLTAIC SYSTEM SUCH AS LABEL 5 OR LABEL 6 MUST • DISCONNECTING MEANS[NEC 690.13(B)] [NEC 705.12(D)(3)&NEC 690.64] IDENTIFY PHOTOVOLTAIC SYSTEM COELECTRICAL NTRACTOR NO: [NEC 705.12(D)(3-4)&NEC 690.64] HOME IMPROVEMENT CONTRACTOR ....m 198080 CONSTRUCTION SUPERVISOR LICENSE n .© 0 04L]r C> � V . . II CS-111662 BUSINESS ELECTRICAL CONTRACTOR ( CAUTION ' LICENSE 902-EL-Al s1( . \�� I IT�L11)) - MASTER ELECTRICIAN 1136 MR Ic�H�Y uI o p,_, 0 INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTED 0 '- - - IMP o rAfiN �oBID:Fos53ss POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE PROJECT NAME FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN Q LABEL 9 LABEL 8 AT: >< MAIN SERVICE PANEL& UTILITY METER, Cl) O AT RAPID SHUTDOWN SWITCH [NEC 690.56(B)]. AT UTILITY METER AC DISCONNECT& INVERTER 00 ~ LETTERS AT LEAST 3/8 INCH;WHITE ON RED BACKGROUND; ' [NEC 690.56(B)] W (0 O Li 0 REFLECTIVE[IFC 605.11.1.1] INVERTER - O CC U "" Q Q +Ria vr:�:11�,IJ�r,¢ talrElt -t 9.47 E, O INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTED .itmi, ci,i x-4v` a will--.--- — U) o } y vi i,,,,,Pr aIgiiEM ru1rir1 - W . . Li. 0 PHOTOVOLTAIC SYSTEM DISCONNECT LOCATED =r ttrxE tx�s)m ttrnra 380 '''l = CO 0 SOUTH-EAST SIDE OF THE HOUSE ' ,y,P. '`�r'�,t4LV *N`ii ” Z +ta)c rci_:�,/al�)' 480 I O ,,,h ottitsl,vc)I?( DJi" N O O O PLAQUE itz• J 1.7 ;r . (L- 15 pp r z i— . r: LOCATION: Q El DC DISCONNECT, INVERTER PV MODULES ›.. < I o111-0 �" (PER CODE: NEC 690.53) Q 1YN0,1[ 1 oif , LTA1 IC (/)e® Ynjay]� ® F SHEET NAME WARNING LABELS & - (N)INVERTER PLACARD LABEL 10 ;' (N)SMART PRODUCTION METER - (N)AC NON FUSED DISCONNECT SHEET SIZE AT EXPOSED RACEWAYS, CABLE TRAYS,AND OTHER WIRING METHODS;SPACED AT MAXIMUM 10 FT SECTION OR WHERE j ANSI B SEPARATED BY ENCLOSURES,WALLS, PARTITIONS, CEILINGS, OR FLOORS. (E)UTILITY METER - 11" X 17" [NEC 690.31(G)] (E)100A MAIN SERVICE PANEL SHEET NUMBER LETTERS AT LEAST 3/8 INCH;WHITE ON RED BACKGROUND; REFLECTIVE WITH(E)100A MAIN BREAKER [IFC 605.11.1.1] 2 STILES RD PV-6 1 -10 11 -20 21 -30 31 -40 41 -50 51 -60 ,tNOFMAs IMNA POWER OPTIMIZER CHART METHODE GNB 1 L' ELECTRICAL N NO.53873 Ox, ISTEik FSSiONALe\° Exp:6/30/2022 2 -- FGR Eb'En' FREEDOM FOREVER MA 135 ROBERT TREAT PAINE DR. 3 TAUTON,MA 02780 TEL:(800)385-1075 VERSION DESCRIPTION DATE REV INITIAL RELEASE 08-13-2021 UR 4 ELECTRICAL CONTRACTOR NO: HOME IMPROVEMENT CONTRACTOR 198080 CONSTRUCTION SUPERVISOR LICENSE CS-111662 5 BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-Al MASTER ELECTRICIAN 1136 MR JOB ID:F095368 PROJECT NAME 6 o = o I- CD co o O _ a Q o Q 7 U o >- o 111114414111"111° � w . - 1 = co O 0 CD m N 2Oz 8 Z Q Q >_ 9 SHEET NAME OPTIMIZER CHART SHEET SIZE STILES KD ANSI B 10 11" X17" SHEET NUMBER PV-7 MARK U P KEY / MHODE\ \j"OFME SAFETY PLAN ! o MANIRAGUHA S � ELECTRICAL m N0.53873 INSTRUCTIONS: 4o, /STERE �<�C F SS/ONALENG\ 1. USE SYMBOLS IN KEY TO MARK UP THIS SHEET. (P) PERMANENT ANCHOR 2. SAFETY PLAN MUST BE MARKED BEFORE JOB \ Exp:6/30/2022 STARTS AS PART OF THE PRE-PLAN �T�' TEMPORARY ANCHOR 3. DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE & MAKE NOTES ON THE JHA SHEET 'ir nal e } ;LA~ " INSTALLER LADDER ` "R` ``" IN CASE OF EMERGENCY FREEDOM FOREVER MA _ 135 ROBERT TREAT PAINE DR. A 02780 B JUNCTION / COMBINER BOX TEL:(80 M85-107 NEAREST HOSPITAL OR OCCUPATIONAUINDUSTRIAL CLINIC TEL:(800)385-1075 VERSION NAME: S STUB-OUT DESCRIPTION DATE REV - - INITIAL RELEASE 08-13-2021 UR ADDRESS: SKYLIGHT SAFETY COACH CONTACT INFORMATION v,,. NAME: 1) NO LADDER ACCESS (STEEP GRADE ELECTRICAL CONTRACTOR NO: IlL �-.-,.-,/ OR GROUND LEVEL OBSTRUCTIONS) HOME IMPROVEMENT CONTRACTOR 198080 ADDRESS: CONSTRUCTION SUPERVISOR LICENSE CS-111AL2 ' RESTRICTED ACCESS BUSINESS ELECTRICAL CONTRACTOR ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE LICENSE 902-EL-A1 MASTER ELECTRICIAN 1136 MR SAFETY PLAN AND SIGN INDICATING THAT THEY ARE I AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR CONDUIT JOB ID:F095368 WORKING SAFELY. PROJECT NAME HTF NAME SIGNATURE 0)-- -- HU WATER SHUT OFF J oo w _ co Li 2 �7J SERVICE DROP < 0 o o cc I / �ZJ POWER LINES 2c, W o u_ ---------- > f= o zZ u, N p : 0 >k Q 2 SHEET NAME DATE: TIME: SAFETY PLAN SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-8 • > JOB HAZARD ANALYSIS `''vp OF MgSS Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture �� 90 Ladder Access o 9 METHODS GJ, • Ladders must be inspected before each use. o M• Company,Client and Public property shall be protect from • New employees must be acclimatized. New employees will be• Extension ladders must be set up on a firm and level surface at ELECTRICAL N a 4-to-1 to run (or 75 and the top be • falling objects. monitored by their Crew Leader(site supervisor)for the first two NO.53873 secured risetthe structure.un angle(or 75Extendegrees)style ladders placed muston Pets(including dogs)shall be secured by their owners prior to (2)weeks of employment or longer when necessary. work start. • Employees will be allowed and encouraged to implement P �o �Q uneven,loose or slippery surfaces must additionally have the • The client should not leave pets,family members,or others in scheduled breaks during each shift.Employees must take oiFs /srER G\F base firmly anchored or lashed so the base will not slip out. the charge or care of Employees,Contractors,or Temporary cool-down breaks in the shade any time they feel the need to do S/ONALN • Extension ladders must be used with walk-through devices or Workers. so to protect them from overheating.Supervisors are the ladder must extend 36"above the stepping off point. Crew leader responsible for communication with the client: REQUIRED to allow employees any break period they need Exp:6/30/2022 • A-frame ladders must only be climbed with the ladder spreader during high heat conditions. bars locked in the open position;A-frame ladders shall not be climbed while in the closed position(ex,closed and used while • Client and public is excluded from work area by barricades(N/A, • Cool Vests are encouraged for all employees at all times during Yes,No): periods of high heat. leaned against a structure). • '' ° ._ C".] t • Additional notes: Identify the location of the closet Occupational/Industrial Clinic G G L..t:. C� i l Training_and Pre-Job Safety Briefing or Hospital in case a crew member becomes ill. _. `OVER RE • All employees onsite shall be made aware of the specific FREEDOM FOREVER MA Mobile Equipment hazards of this project and review this HJA during a pre-job What is the specific plan to provide and replenish sufficient water for 135 ROBERT TREAT PAINE DR. • Only Qualified operators will operate equipment;operators must TAUTON.MA 02780 maintain a certification on their person for the equipment being briefing,and their signature indicates awareness of site all employees on site? TEL:(800)385-1075 operated. conditions and the plan to eliminate any hazards identified prior • If offsite replenish is necessary,where will you go to replenish • operated.)of mobile equipment(Type/Make/Model): to and during the project. water(location/address): VERSION • Crew leader(name/title): :: _:-: __ _-. - -- -.-.---_ __-. _.. _-__ --_ DESCRIPTION DATE REV • Qualified operator(s): - - .- -_: - - • Who will replenish the drinking water(name): INITIAL RELEASE 08-13-2021 UR • Crew member(name/title): Restroom facilities - Material Handling and Storage - • Materials will be staged/stored in a way that does not present a • Crew member(name/title): • Employees shall have access to restroom facilities with hazard to client,personnel or public.Materials stored on the hand-washing stations.Use of onsite restroom is at the client'sII roof will be physically protect from failing or sliding off. • Crew member(name/title): discretion(location is annotated below). If client does not give ELECTRICAL - permission, location of suitable restroom facilities with CONTRACTOR NO: Fall Protection • Crew member(name/title): hand-washing stations offsite will be provided.The onsite HOME IMPROVEMENT CONTRACTOR • supervisor will identify location and make arrangements to 198080 A site-specific plan for fall prevention and protection is required -_ ----- --_ CONSTRUCTION SUPERVISOR LICENSE prior to starting work and must remain onsite at all times until • Crew member(name/title): ensure all employees have access at any point. Cs-111662 • Restroom facilities will be(circle one):Onsite-Offsite BUSINESS ELECTRICAL CONTRACTOR work is complete;a fall rescue plan must be outlined and _____ __ _s� _ LICENSE 902-EL-Al discussed among the crew prior to work start. Airborne Contaminants: • If Offsite,add location name and address: MASTER ELECTRICIAN 1136 MR • First-person-Up(FPU)must install their anchor and connect • Asbestos-containing(Transite)piping(ACP)-Do not disturb before any other task,including installing other anchors.The (move,drill,cut fracture,etc.) Incident Reporting Procedure JOB ID:F095368 Last-Person-Down(LPD)must be the only person on a roof • Asbestos-containing thermal insulation(ACI)and • Contact your Site Supervisor PROJECT NAME uninstalling fall protection. Asbestos-containing duct wrapping(ACW)-do not disturb,no Name: Q • FPCP(name and title): attic or crawlspace access is allowed if work to be performed could cause exposure to personnel,client or public. Phone: . p cp _-- --- - - -- ContactMana Manager • FPU and LPD(name and title): Weather and Environment your9 d„ O D • The site supervisor shall forecast the weather conditions at the Name: J co O O Electrical Safety y job site, prior to crew arrival,in order to mitigate any hazards Phone: W J • The Electrical Qualified Person(EQP)is required onsite to associated with inclement weather(heat,cold,wind,rain,etc.) Q o N O C[ perform electrical work. • The site supervisor will utilized a portable wind meter • Contact your Site Supervisor Q X— Q U • All electrical work will be performed with equipment in an (anemometer)to verify actual onsite wind conditions,by Name: — w '' O LLelectrically safe condition(de-energized)unless approval has checking at the ground and on any elevated work surface(ex, been granted prior to work. rooftop)prior to work start,at midday and prior to solar panel Phone: • Service drops and overhead electrical hazards will be staging on a roof. - -I = CO O With:Your full name,phone number,office location,brief description indentifiedand protected from contact,as neccessary. • Elevated work involving the moving or maneuvering of solar of what happen and when. f— CI)N. Z • EQP(name and tile): panels shall cease at 25mph(sustained wind)until wind D O _ - __ -_ _____ subsides. NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE Q CV 0 O • Forecasted weather maximum temp(degrees F): (add as many as necessary by using additional sheets) If yes,list specific tasks and protection in place: m F'- Heat Related Illness Prevention Define the Hazard: Method/steps to prevent incident: Q< < • Employees shall have access to potable drinking water that is Q fresh,pure,and suitably cool.The water shall be located as CD close as practicable to the areas where employees are working. SHEET NAME Water shall be supplied in sufficient quantity at the beginning of Define the Hazard: Method/steps to prevent incident: JOB HAZARD the work shift to provide at least one quart per employee per hour for drinking for the entire shift.Employees may begin the ANALYSIS shift with smaller quantities of water if they identify the location and have effective means for replenishment during the shift to Define the Hazard: Method/steps to prevent incident: SHEET SIZE Public Protection employees to drink on quart or more per hour.The _ - -- , - -_- --- --__ _ _ _ ANSI B • The safety of the Client and the Public must be maintained at all frequent drinking of water shall be encouraged. 11times. • Shade shall be present when temperature exceeds 80 degrees �� X 7" • The Client and the Public shall be prevented from entering the Fahrenheit.When the outdoor temperature in the work exceeds Define the Hazard: Method/steps to prevent incident: SHEET NUMBER work zone through the use of barriers and/or signage,as 80 degrees Fahrenheit,employees shall have and maintain one required. or more areas with shade at all times. PV-9 I T HYUNDAI SOLAR MODULE �� i_- Electrical Characteristics :, y Nlmw-CrystaWneModule` S �8 i ' 1 1 , L111111111111 lll�) l� I flo�linel0}i�utjtnppt 290 295 300 305 Mono-Crystalline Type Dpen Ctrcul gWtage 39.6 39.8 40.0 40.4 HiD-S290RG(BK) HiD-S295RG(BK) HiD-S300RG(BK) �Or,. , I 1111 Il 11 l '!" CittpukC Ti( R. ., 9.7 9.8 9.8 9.8 HID-S305RG(BK) III! 1 ME II Voltage a Plnex rep•.) 7 31.9 32.3 32.5 32.9 Cnt�t :i11.9.), 9.2 92 9.3 9.3 BLACK d:if 1 11-,1 I (rd} .j 11I"1 Ill 1 , Module Ef lclen ! 17.3 17.6 17.9 18.2 t p 1 e • mono-cry. silicon (I: )Aaixtmum System Voltag 1,000 Temperaturo Coetfa ieiitof. iaaz al 0.391 „,,,,,.„,,,,, ,,,„60 ., , ,„ 446,... 4. t ) 5�11 TemperatoreCoeff(uaifo�Voc 0.31 eat rata u.. a ofl 0.031 rx ,-,, .. ,,,..,,,.:4,, ; � et11111111 ii �- P 4' PB • NI data at STC(Standard rest Conditions).Above°�a may changed without prior nonce. Ia,kroduIe Mor owe semb e• a n,. lee,.i sig Gene tion 1.U5A, (( g ::at f(1 fta.. .-R f ov� t r oda 1 ttx. jl - ,ndaI C i ' 1 ,) �.I r� 4:7 Mechanical CharacteristicsInstallation a Guide Safety• !IllhI11 i +� edpersonel should install or ,r 1 �� D ns : 1,001 mm(39.40')x 1,67Smm(65.95")x 33mm(1.3") perform maintenance. •Be aware of dangerous high DC voltage. _ y .F Weight•, $' 18.0kg(39.7Ibs) 9 9 ss �� J`� •Do not damage or scratch the rear surface sefibled sn •Solar C is'40,,,,",' 60 cells In series(6 x 10 matrix)(Hyundai cell) of the module. �_••• 1 •*; . n •Do not handle or Install modules when they - lu 4 • - 4 mm'(12A4dG)cables with polarized weatherproof connectors, are wet. CEO•= � Du Cables , ®�b7 IFC ceriif.ed(E1L listed),Length 1.4 m(39.4) _ • r PERI Technology Anti LID/PID T T T Mechanical Strength . Nominal Operating 46°C 3 2 IP65,weatherproof,IEC certified(UL listed) 7111111T-t., Cell Temperature PERL technology provides ultra-high Both LID(Light Induced Degradation)and Tempered glass and reinforced frame - Operating Temperature 40-85°C B Diodes 3 bypass diodes to preventpower decrease by partial shade efficiency with better performance In low PID(Potentlal Induced Degradation)are design withstand rigorous weather p Maximum DC 1,000V(UL) irradiation.Maximizes installation capacity strictly eliminated to ensure higher actual conditions such as heavy snow and strong '' System Voltage in limited space, yield during lifetime. wind. , p ". . En apsunt las:Anti-rsfiectian coated glass,3.2 mm(0.126°) Maximum capsulant:EVA I Back Sheet:Weatherproof film Reverse Current 25A Clear anodized aluminum alloy typo 6063(Black Color) Maximum R Rear 113 psf '`" Cosign Load Rear fi4 psi Nae 0YDE • � Reliable Warranty ,,,,•,�,1_ Corrosion Resistant UL/VDE Test Labs Module Diagram runt:rum) HYUNDAI , „ g ( I-V Curves Global brand with powerful financial Various tests under harsh environmental Hyundai's R&D center is an accredited test 37.8(961) Current[A] strength provide reliable 25-year conditions such as ammonia and salt-mist laboratory of both UL and VDE. e warranty. passed. 11 4.20 1 ® I e 1 44-i- r T.12 00.26(6.6) 6 nom», 00.35(9) 6 Hyundai's Warranty Provisions About Hyundai Energy Solutions o 3 -ace ewo 50 Te wemp=x2s•c t -Oymew6 Cat Temp.45°c ,.. Established In 1972,Hyundai Heavy Industries Group is one of the most trusted names in the $ -0pae"p0atC0D-6� (� •10 Year Product Warranty °0 I 10 16 20 25 a0 as i, 4s heavy industries sector and is a Fortune 500 company.As a global leader and innovator,Hyundai g Vaagelyl EARS •On materials and workmanship Heavy Industries is committed to building a future growth engine by developing and investing a Current[A] u heavily in the field of renewable energy. � � � ce,�mp •25-Year Performance Warranty 10 •Initial year:97% As a core energy business entity of HHI,Hyundai Energy Solutions has strong pride in providing 6 -mamea-1 ma+um - •Linear warranty after second year: high-quality PV products to more than 3,000 customers worldwide. 6 -mauler.eoawhm with 0.7%p annual degradation, koala]=6ouww 80%Is guaranteed up to 25 years 0 0.35(9) 2g . 4 �1I 1132 . II -ma mal=su jww (287.50) (lid °0 10 20 b dD � IyI Certification , 39.4(18811 1.30(33) ISP" HYUNDAI ..:: HYUNDAI ENERGY SOLUTIONS ENERGY SOLUTIONS ((( Sales&Marketing www.hyundai-ezco.kr Printed rate.118079 NO ° 2 ;Ny I w 55,Bundang-ro•Bundang-gu,Seongnam-si,Gyeonggi-do.13591,Korea I info@hyundai-es.co.Fr Primed Date:t taot9 FSC Tel:America:+1-212-220-5764,Japan:+81-3-5717-4435 I Fax:+82-31-8006-6967 Europe:+49-89-71042-2023,Australia:+61-2-9238-2283 f Single Phase Inverter With HD-Wave Technology for North America immi S• SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ ingle Phase Inverter SE7600H-US / SE10000H-US / SE11400H-US with H D-Wave T'echncIoçjyOUTPUT —__ _ a9.,0-ti 240b` 6:CC CP 11400 @ 240V Rated AC Po er OutFiU 3L1t10 5000 7603 10'30 VA I 3830 a 238V 2Cu0 Li`203V 12/300 tat 203V for North America 7Cji J0 &COO 0, 40V 1a301 =40V 7 z mu T AL Pur Outpu ' 3CJ0 3 J 'rJS`J SOOD 50 CS:208V 7600 ly'JO 1}00J Cir 2J'J VA Ar Out,ul`vv ag Adin-f um-"1sx II SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / 2 1 ! r SE7600H-US / SE10000H-US / SE11400H-US —1 °�t "� �'� ' "' x ti a3 < b < '7 I _t!4 7xfa� AC Fr gJe :v(N .ince) 1 53.3•6C•-E,CS Hz Maxrtn0rnCcn.rucxts Output A {yl, C Er t CJ24JJ 12.5 i6 I 21 25 32 42 473 A o Solar 177 ...HD 'fY;TIV.i 4'I _.—. "! Xma Tur Ccr nuous Ou put i Current 02J3J i6 i 24 1 4$5 A GFDI Th extol.. I 1 - — A 0 t 0 s I .nto , 1arII g P c n,I solariz I�.:;.. Col Wiry Cnn 1urob,e Thrc sl g 'is I Yes INPUT O. t;3 Alan mum CC Power a/240V 465,0 I c'ha0 I 7750 9330 I 11630 I 155010 I.� 176;0 L4 Maximum CC Pacer 0.233V ����_ _ 5100 7750 — 15500 W O a Q li _ Tia -fur er Ioss.Ungrounded I ls-25 ••O• ••••O O I 5 r r,,v;ln„u In c,c ( 483 Vdc 323 4 Vdc trilaxrravorn IripLit Current W4Clnitr 8S r 105 135 155 I 20 27 I 305 At-Jt O 0 0 fvf Mraxtraiut,hip it G,rr.r.t/K 5V-' - 9 - 11 5 ( - , I 27 A:9r � II 1st r :, Max.Input Short Circut Current 45 Adc p 6f Reverse-Pula ity Prctrctr n + Fes O 4I 1 -_.. -.—_ G u 33-Fad' I olat un Dctocha`, 1 ECt u `ern.t y ,1 u r Inca,Ler EP�cnsncy 49 902 gE I 6 CEC 11As oht,x1 Efl r-ncy 999I 10 240V I 935(I 208V O 0 0 0 Nr:ghttme PDwcr Consumptor. e 23 W ADDITIONAL FEATURES Sur portnr3 Con r,sunrcat ion Int iaces 05465,Etf erect ZigOrne(aptx;na),Ce lutar(op-ionai) j I Revenue Grade Dana ANSI C12 20 0 pt,or0s1„ _� t Rapid StL do a n NEC 2014 ard Auton aL.F,e.,i0 Sktkisms upon AC Gri3511srcnne 1 Optimized installation with HD-Wave technology7N2 STSTANDDARD COMPLIANCE Safety UL1741,ULt/41 SA.1.11,1699E,CSA C22.2,Canai:an AF Ci according to II L "1.07 I Specifically designed to work with / Extremely small Grid Connei on Standards 5151541,„,;:e 21.Pniee 14(141 v J power optimizers E :criers 1 KC Part 15 Class E INSTALLATION SPECIFICATIONS I Record-breaking efficiency / Built-in module-level monitoring ACOutpctConda:Sze/A,.G Rjirlv 1 r r.1.3xm m714-6n :c P Max.mum/1:4A:;G I DCC Rat Cordon Size/p c.'Srnngs/I 1'1 aurnurn/1-2 strings/14-6 A:L'c 1'ttiloxunuon/13 S11.1195/14-6 AWG i Fixed voltage inverter for longer strings I Outdoor and indoor installation ANC Rance D t WxD;ensiors wan Sifa!y Sr,;;c1 1 17.7 x146 x 6E 7450 x 370 x174 21.3x146 x'7.3/540 x 370 x 194 'n/ Ram ��' ;H... / Integrated arc fault protection and rapid shutdown for / Optional:Revenue grade data,ANSI C12.20 t.JelghttvthSafelySe,uh 1 _ 22/10 251/114 _ 262/1, 323/iz_ii 1:/Lg_ NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5%accuracy) Nose _ <25 I <S0 d"aA Ccal:ng -- NaturalConvect:an I UL1741 SA certified,for CPUC Rule 21 grid : operato_g Te-p r�oreFangt 13 to.143 7-25 t0 60 (-40'F/-40"C option) F 1'C compliance Pruhi,cn FastingNE”-0A 4X(Inverter with Sarty Str'ch) _. -- ---- a,For other regional settings please contact Solar Edge support C A higher current source may be used;the Inverter will troll Its Input current to the values stated g s o l a r,V Y w Revenue grad inverter PIN:on refer to:0tpsj For power de-ratng inforre0on refer to:https7/www.soloredge.con7stesrde`aul;tfileyse-temperature-derating-note-na.pd` solaredge.com N-40versonP/N SExxurti-USOWNNU4 a C SolarEdge Technologies,Inc NI rights reserved.SOUREDGE the SalarEdge logo.OPTIMIZED BY SOIAREDGE are trademarks or registered trademarks of Sol Edge Technologies Inc All Ro H S other trademarks mentioned herein are trademarks of thee respective owners Datc 032019/V0l/ENG NAM.Subject to change without noted. Al Power Optimizer For North America Power Optum ze r P320 / P340/ P370/ P400 P401 / 405 / P485 / P505 0P340 P370 P401 Optimizer model P320 for high- (for higher P400 P405 P455 P505 For North America p ( 9 P (for high (for high- (for high- (for higher (typical module (for 60-cellpower ower (for 72& 60 and 72- 96•cell power 60 voltage voltage current P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 compatibility) modules) 60-cell and 72 cell cell modules) modules) modules) modules) modules) modules) odules) m INPUT --‘ Rated Input DC Power° 320 1 340 370 400 405 485 505 W (..,------ 1 Absolute Maximum Input Voltage ,t7 ) 70 (Voc at lowest temperature) 48 60 80 60 125Rr 83° Vdc ) MPPT Operating Range 8-48 8-60 8-80 8-60 12.5-105 12.5-83 Vdc .. I /J r' Maximum Short Circuit Current i �� 101/ 1T9ias0 (Iso 11 10.1 11.75 11 14 Adc Maximum DC Input Current 13.75 12.5 14.65 12.5 17.5 Adc Maximum Efficiency 995 % MO Weighted Efficiency 98.8 98.6 % [ Overvoltage Category II H 'f r OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc '' Maximum Output t Voltage 60 Voltage 85 Vdc ---, OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) I Safety Output Voltage per Power Optimizer 1 a 0.1 Vdc ;STANDARD COMPLIANCE N EMC FCC ParttS Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 Material UL94 V-0,UV ResiCant RoHS Yes I INSTALLATION SPECIFICATIONS Xill Maximum Allowed System 13300 Vdc Voltage Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions(),NixLxH) 129x153 x27.5/5.1x 6 x1.1 129x153x33.5 129x153x29.5 129x159x49.5/5.1x6.3x1.9 129x162x59/ mm /5.1x6x1.3 /5.1x6x1.16 5.1x6.4x2.3 /in Weight(including cables) 630/1.4 750/1.7 655/1.5 845/19 1064/23 gr/lb Input Connector MC4ut Single or dual MC4s MC4sl Input Wire Length 0.16/0.52 m/ft Output Wire Type/Connector Double Insulated/MC4 Output Wire Length 0.9/2.95 12/3.9 m/ft PV power optimization at the module-level Operating TemperatureRange° 40-+85/-40-+185 C/'F Rating Protection Rating IP63/NEMA6P Relative Humidity 0-100 9(, / Specifically designed to work with SolarEdge / Fast installation with a single bolt (1)Rated power of the modue at STC will not exceed the optimizer'Rated Input DC Power'.Modules with up to+5%powertoleranxareallowed (2)NEC 2017 requires max input voltage be not more than 80V inverters (3)For other connector types please contact SolarEdge Next (4)maintenance with module- (4)For dual vets',on for parallel connection of two modules use P435-4NMDMRM.In the case of an odd number of PV modules in one siring,insialing one P485 dual vesen power optimizer connected g to one PV module.When connecting a single module seal the unused input connectors with the suppiicd parr of seas. / Up to 25%more energy level monitoring (51 For amb.ent temperature above.851C/+185"F power derating is apish.,.Refer to Power Optimizers Temperature De-Rating Technical Note for more details. / Superior efficiency(99.5%) / Meets NEC requirements for arc fault PV System Design Using Single Phase Three Phase for Three Phase for Single phase protection (AFCI)and Photovoltaic Rapid a SolarEdge Inverter< HD-Wave 208V grid I 277/480V grid / Mitigates all types of module mismatch losses, Shutdown System (PVR55) Minimum String Length P320,P340,P370, P400,P401 s 10 18from manufacturing tolerance to partial (Power Opt xers) P405 P485, P505 6 8 14 shading / Module-level voltage shutdown for installer Maximum String Length(Power Optimizers) 25 25 500 and firefighter safety 5700(6000 with / Flexible system design for maximum space Maximum Power per String SE7600-US-5E11400- 5250 60000 12750" W US) utilization Parallel Strings of Different Lengths or Orientations Yes (G)For detailed Zing sizing Inforrnahun refer to:hall/www.sciaredge.core/s:tes/detault4ies/wir s:zing-na pct (7)It is not allowed to mu P405/P485/F505 with P320/P340/11370/P4zO/P401 in one 4r:ng (8)A gr,rg with more than 30 cptimizers does not meet NEC rape shutdown requIrenentx safety voltage wit be above the 30V requirement (4)For 208V gnd rt is allowed to install up to 6,500W per string when the maximum power d0erence between earn tiring is 1,003W (10)For 277/480V grid:Nis allowed to entail up to 15,000W per string when the maximum power difference between each string is 2,030W solaredge.com s o l a rr/ o 1-61.- c -',..,'"', , O SuiwEdge Technologies Ltd AN rights reserved.SOL/WOGS.the SolarEdge logo.OPTIMIZED BY SOLA.EDGE are trademarks or registered tredeman¢of SolarEdge Technologies Inc .6.. RoHS Alt other trademarks mentioned herein are trademarks of then respective owner.Date.0412020/Y1171ENG NAM.Subject to change without nonce. Intertek a ) I Product datasheet DU221 RB Characteristics t" Main Product or component type Single Throw Safety Switch MLA 1, Line Rated Current 30 A I. Product certifications UL listed Jrr NEMA degree of protection NEMA 3R i Disconnector device type Non-fusible disconnect IDevice composition None I 3 Device mounting Surface i Number of poles 2 Electrical connection Lugs Series name General duty Complementary E E Environment i s 8 g Offer Sustainability z. WARNING:This product can expose you to chemicals WARNING:This product can expose you to chemicals including: including: Lead and lead compounds,which is known to the State Lead and lead compounds,which is known to the State of California to cause cancer r4 m of California to cause cancer and birth defects or other and birth defects or other reproductive harm. �o m . reproductive harm. 3121 For more information go to www.p65warnings.ca.gov For more information go to www.p65warnings.ca.gov P alllt e lig E Contractual taan.anty , WarrantyyQE period 18 months 8 b f{° $m iom a t ia�p E c-ab >9mcm ��ms eaom flu mat me o s c @Som Egm 11yc Ba , 1741 j �.9 1 ow ccs yEbc ��zu ' V PART#TABLE PART#TABLE P/N DESCRIPTION P/N DESCRIPTION 250010U SFM SPLICE 6.5" 250030U SFM ATTACHED SPLICE 8" r+3 1/8" 8 3/16" —3 3/16" 6 11/16° r 1,.:. I� MMIU IMRE 11114 in ' 51/16" ' _ �� 411 PIMmini 2 3/4" i� �i =° • A i.410 C).% I -.tare cl _;;;.04._ -,i:,.,i..-„,,.-./0,#.'?", , ::.11:: %,s(-.%0‘,/ ,, 3•05,_;.WO s • • ‘ 49° ,fi,--- ,-- ,,, ,--- , , .-- 441d ,,,, - v 4440 ,-,<.2,- , ... ., ---.-011 Hiii:.7,,,,, ,,T , ',-' y ,op r SFM SPLICE 6.5" SFM ATTACHED SPLICE 8" NI PRODUCT LINE: SFM INFINITY 1 DRAWING NOT TO SCALE PRODUCT UNE: SFM INFINITY , DRAWING NOT TO SCALE a© s'�� ?tom lO ALL DIMENSIONS ARE o �26.],UN 1[ ' ALL DIMENSIONS ARE Q au n a DRAWING TYPE: PARTS ASSEMBLY NOMINAL ';t DRAWING TYPE: PARTS ASSEMBLY NOMINAL , 1411 BROADWAY BLVD.NE Z 1 1411 BROADWAY BLVD.NE Z ALBUQUERQUE,NM 87102 USA DESCRIPTION: SPLICE 6.5" 1 PRODUCT PROTECTED BY cALBUQUERQUE,NM 87102 USA DESCRIPTION: ATT SPLICE 8" PRODUCT PROTECTED BY LL Ln PHONE:505.242.6411 ONE OR MORE US PATENTS PHONE:505.242.6411 ONE OR MORE US PATENTS WWW.UNIRAC.COM REVISION DATE: 4/22/2019 LEGAL NOTICE SHEET WWW.UNIRAC.COM REVISION DATE: 4/22/2019 LEGAL NOTICE SHEET t . ♦ t I PART#TABLE PART#TABLE P/N DESCRIPTION P/N DESCRIPTION 004270D FLASHKIT SFM SLIDER COMP DARK 008000U SFM N/S BONDING CLAMP 008015S SFM WIRE BONDING CLIP 008100U SFM TRIM BONDING CLAMP 2" 1-1 1/2" 1 ©, ] 11 1 5/16" I 0 1 1/2" 4011gP I STRUCTURAL SCREW 2 7/16" ( rt . W/ 5/16 BND SS EPDM WASHER _ V � 8 1/16" c 111111111.011' 1 3/8" a j , 2 3/4" TR k 6110.1 1 " ..•-"- "1. ..1 SLIDER GROMMET 1 7/16" ft ASSEMBLY N/S BONDING CLAMP 8" FLASHING 3/4.___.. .3 ,s L 6 1/2" J 5/16" FLASHKIT SFM SLIDER WIRE BONDING CLIP / ,t, • , _:. - PRODUCT LINE: SFM INFINITY � DRAWING NOT TO SCALE Ln -:,- PRODUCT LINE: SFM INFINITY DRAWING NOT TO SCALE eV 00 Q a°o' .:1 Liv:- DRAWING TYPE: PARTS ASSEMBLY NOMINAL Q ALL DIMENSIONS ARE o ALL DIMENSIONS ARE .--� DRAWING TYPE: PARTS ASSEMBLY NOMINAL , 1411 BROADWAY BLVD.NE Z 1411 BROADWAY BLVD.NE Z ALBUQUERQUE,NM 87102 USA DESCRIPTION: FLASHKIT SLIDER PRODUCT PROTECTED BY l ALBUQUERQUE,NM 87102 USA DESCRIPTION: BONDING 'PRODUCT PROTECTED BY /1"- PHONE: LPHONE:505.242.6411 ONE OR MORE US PATENTS PHONE:505.242.6411 ASSEMBLIES ONE OR MORE US PATENTS cn WWW.UNIRAC.COM REVISION DATE: 4/22/2019 LEGAL NOTICE SHEET WWW.UNIRAC.COM REVISION DATE: 4/22/2019 ` NOTICE SHEET 4 ' ' PART#TABLE PART#TABLE P/N DESCRIPTION P/N DESCRIPTION 256625U SFM TRIMRAIL UNN DARK 250110U SFM UNIV TRIMRAIL CLIP DARK 1 - 2 7/16" 1 12" $^ l 3 1/16" 1111 111 23J16"1 v 5'-6 1/4"�/,-- i Mil 2 1/16" L1 403 4aiih---ir_„44t_ 1 4 4,,r( . 1441*.i.i. . po, SFM TRIMRAIL UNIV UNIV TRIMRAIL CLIP .r.= PRODUCT LINE: SFM INFINITY DRAWING NOT TO SCALE .-� -, PRODUCT LINE: SFM INFINITY 1 DRAWING NOT TO SCALE ®® ALL DIMENSIONS ARE o nno.0� I ALL DIMENSIONS ARE alQ ata, :_ —y no �a ti:. DRAWING TYPE: PART NOMINAL DRAWING TYPE: PARTS ASSEMBLY NOMINAL 1411 BROADWAY BLVD.NE ; 1411 BROADWAY BLVD.NE Z ALBUQUERQUE,NM 87102 USA DESCRIPTION: TRIMRAIL UNIV PRODUCT PROTECTED BY ALBUQUERQUE,NM 87102 USA DESCRIPTION: UNIV TRIMRAIL CLIP PRODUCT PROTECTED BY PHONE:505.242.6411 ONE OR MORE US PATENTS PHONE:505,242.6411 ONE OR MORE US PATENTS WWW.UNIRAC.COM REVISION DATE: 1/29/2020 LEGAL NOTICE SHEET WWW.UNIRAC.COM REVISION DATE: 4/22/2019 LEGAL NOTICE SHEET PART#TABLE P/N DESCRIPTION 250120U SFM TRIM SPLICE ASSEMBLY DARK 111 2 5/8" I 1 13/16" 1. 8" 1T SFM TRIMRAIL SPLICE - PRODUCT' NE: SFM INFINITY DRAW0 DRAWING NOT TO SCALE 1 U LI, ALL DIMENSIONS ARE q as �.` DRAWING TYPE: PARTS ASSEMBLY NOMINAL J 1411 BROADWAY BLVD.NE z ALBUQUERQUE,NM 87102 USA DESCRIPTION: TRIMRAIL SPLICE PRODUCT PROTECTED BY LL- PHONE:505.242.6411 ONE OR MORE US PATENTS WWW.UNIRAC.COM REVISION DATE: 4/22/2019 LEGAL NOTICE SHEET , , a 00 F M CVCTM BONDING GROUNDING OO FRf E UL CODE COMPLIANCEHOTES 00 C O P L IISTALLATIOH! GUIDE PAGE 00 f,fCfl0 AILTM INSTALLATION GUIDE PAGE �� (±) o- +_�,I' ' I ft1 _ •� -a 1- ie --i,I �� \,, i'" ' SYSTEM LEVEL RECLASSIFICATION installation thespecified` 'v° �'- rL C4 Thesystemfireclassrating requiresto tion in manner sped ed in the performance is inherent in the SFM design and no additional mitigation measures • I; i_L SUNFRAME MICRORAIL(SFM)Installation Guide.SFM has been classified to are required.The fire classification rating is valid for any roof pitch.There is no :t I -T the system level fire portion of UL 1703.This UL 1703 classification has been required minimum or maximum height limitation above the roof deck to maintain } I L b •� P" incor orated into the UL 2703 product certification.SFM has achieved Class A, the Class A,B&C fire rating for SFM.SUNFRAME MICRORAILTMcomponents shall -, —�La, _ r� f --_- --- :— I ��' B&C system level performance for low slope&steep sloped roofs when used be mounted over a fire resistant roof covering rated for the application. Cr�3- 0.—.7 - r in conjunction with type 1 and type 2 modules.Class A,B&C system level fire - Module Type Roof Slope 1 System Level Fire Rating Microrail Direction Module Orientation 1 Mitigation Required ol , � � a 1__e_ ( Type 1 and Type 2 Steep Slope&Low Slope Class A,B&C East-West Landscape OR Portrait None Required •• with 20 re`re e-installedpe 1 o module andis whichaccomplished Pg i See page's'for a list of modules that were electrically and mechanically tested /irk P 3 _ T or qualified with the SUNFRAME MICRORAIL(SFM)components outlined within �" $r -- -- '— this Installation Guide. '+ -:- :: +ff on a secure si e o e icroral an s ice. dg •t t - , i i I_ j -_I 1 j j I 1 ( I I 1 1 T : • UL2703 Design Load Ratings: ""' 5)- t...... t..s. r. `fs „L tIG a) Downward Pressure-113 PSF/5400 Pa ` 'we�� " b) Upward Pressure-50 PSF/2400 Pa \-,`T//_ ta ,_ �'t I c) Down-Slope Load-30 PSF/1400 Pa .� ., N-S BONDING PATH: • Tested Loads: T 1 r 1 wT 1 3 ='� co...4...:400:1" N-S module to module bonding is a) Downward Pressure-170 PSF/8000 Pa . 7L t,- to f „'� at��uc.mt�fu.a:>�..su*; .._-- , �,;m 4,,,,,,,,,;,,, bondinglphnd(W`hrb0�ndlt g6clamp wish 21 t}ral j Upward PrPessure- 75 PSF/3500 Pa -� \. oil- &3 3 , " I u.c,r,., r ru m, fx [ Down-Sloe Load-45 PSF/2100 Pa t 35 1 r 1 ti u • Maximum Span=6ft \ _C i4K'.c,a:24:Irl W ;L:GI:3.ai,.-Sts 6£4 n:.,:it-Lu __ •°• T • Use with a maximum over current protection device OCPD of 30A LUG DETAIL&TORQUE INFO LUG DETAIL&TORQUE INFO LUG DETAIL&TORQUE INFO 1 o 0' • System conforms to UL Std 2703,certified to LTR AE-001-2012 Ilsco Lay-In Lug(GBL-4DBT) Ilsco Flange Lug(SGB-4) Wiley WEEBLug(6.7) j-�� 1�17�f1 y • Rated for a design load of 2400 Pa/5400 Pa with 24 inch span • 10-32 mounting hardware • 1/4-mounting hardware • 1./4'mounting hardware 1 • Torque=5 ft-lb • Torque=75 in-lb • Torque=10 ft-lb 1,11 1 LABEL MARKINGS • AWG 4-14-Solid or Stranded • AWG 4-14-Solid or Stranded • AWG 6-14-Solid or Stranded • System fire class rating:See installation instructions for installation TRIMRAIL BONDING PATH: requirements to achieve a specified system fire class rating with Unirac. �•- - NOTE:ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION Trimrail to module bonding is accomplished with • Unirac SUNFRAME MICRORAILTM is listed to UL 2703. C) C1 �• W in --,... F=- 3 J �" System bonding is accomplished through modules.System grounding accomplished by attaching bonding clamp with integral bonding pin and • All splices within a system are shipped with marking indicating date a ground lug to any module at a location on the module specified by the module manufacturer. bonding T-bolt (ru,.a'.:a�a La s':ri i raa.t;u.) and location of manufacture. , a ?LI 9 I� C lLel l lE l a a 1 L] , Fill _ , 0 0ratitiTi,� Sat lif` �C{ rw1 I : PAGE 1 Manufacture Module Model/Series Manufacture Module Model/Series Manufacture Module Model/Series Aleo I P-Series JAP6 60-xxx,JAM6-60-xxx/SI,JAM6(K)-60/ PEAK Energy Series, CHSM6612P,CHSM6612P/HV,CHSM6612M, xxx,JAP6(k)-72-xxx/4BB,JAP72SYY-xxx/ZZ, PEAK Energy BLK2 Series, Astronergy CHSM6612M/HV,CHSM6610M(BL)(BF)/(HF), JAP6(k)-60-xxx/48B,JAP60SYY-xxx/ZZ, PEAK Energy 72 Series, I CHSM72M-HC JA Solar JAM6(k)-72-xxx/ZZ,JAM72SYY-xxx/ZZ, REC TwinPeak Series JAM6 -60-xxx/ZZ,JAM6OSYY-xxx/ZZ. TwinPeak 2 Series, AXN6M610T,AXN6P610T, O Auxin TwinPeak 2 BLK2 Series, AXN6M612T&AXN6P612T i.YY:01,02,03,09,10 1 TwinPeak 3 Series(38mm) Axitec AXI Power,AXI Premium,AXI Black Premium ii.ZZ:SC,PR,BP,HiT,IB,MW , I Renesola Vitrus2 Series&156 Series Boviet I BVM6610,BVM6612 linko JKM&JKMS Series Risen RSM Series BYD P6K&MHK-36 Series Kyocera KU Series S-Energy SN72 &SN60 Series(40mm) C56V M,CS6P P,CS6K-M,CSSA M, LG xxx S1C-A5,LG xxx N1C-A5, Seraphim SEG-6&SRP-6 Series CS6K-MS,CS6U-P,CS6U-M,CS6X-P,CS6K-MS, LGxxxQ1C(Q1K)-A5,LGxxxN1C(N1K)-A5, CS6K-M,CS6K-P,CS6P-P,CS6P-M, -P, T A4, Sharp NU SA&NU SC Series LGxxxS1CA5, LGxxxA1C-A5,LGxxxN2 Canadian Solar Silfab SLA, SLG&BC Series CS3U-MS,CS3K-P,CS3K-MS,CS1K-MS,CS3K, LGxxxN2T-A5,LGxxxN2W-A5 LG Electronics LGxxxS2W-A5,LGxxxx xxE1C-A5,LGS2W-G4 Solaria PowerXT CS3U,CS3U-MB-AG,CS3K-MB-AG,CS6K, CS6U,CS3L,CS3W,CS1H-MS,CS1U-MS LGxxxN1C(N1K)-G4,LGxxxN2W-G4, SolarWorld Sunmodule Protect, LGxxxS1C-G4,LGxxxE1K-A5,LGxxxN2T-15, SunmoduLe Plus Centrosolar America I C-Series&E-Series LGxxxN1K N1 VS,LGxxx iC N2 V5, ( Q Q ( W) Sonali SS 230-265 CT2xxMxx-01,CT2xxPxx-01, LR6-60&LR672 Series, LONGI Suntech STP CertainTeed CTxxxMxx-02,CTxxxM-03, . LR4 60&LR4 72 Series CTxxxMxx-04,CTxxxHC11-04 Sun iva MV Series&Optimus Series Mission Solar Energy MSE Series Sun Edison/Flextronics F-Series,R-Series&FLEX FXS Series Dehui DH-60M Mitsubishi MJE&MLE Series SunPower X-Series,E-Series&P-Series Eco Solargy Orion 1000&Apollo 1000 Neo Solar Power Co. D6M&D6P Series TP572,TP596,TP654,TP660, FreeVolt Mono PERC Talesun GCL GCL-P6&GCL-M6 Series VBHNxxxSA15 &SA16, TP672,Hipor M,Smart VBHNxxxSA17&SA18, Testa SC,SC B,SC Bi,SC B2 I TD-AN3,TD-AN4, Hansol 1 VBHNxxxSA17(E/G)&SA18E, PA05,P005,DD05,DE06,DD06,PE06, UB-AN1,UD-AN1 Panasonic Trina t VBHNxxxKA01&KA03&KA04, PD14,PE14,DD14,DE14,DE15,PE15H Heliene 136M,60M,60P,72M&72P Series VBHNxxxZA01,VBHNxxxZA02, Upsolar UP-MxxxP(-B),UP-MxxxM(-B) HT Solar HT60-156(M)(NDV)(-F), VBHNxxxZA03,VBHNxxxZA04 URE D7MxxxH8A,D7KxxxH8A,D7MxxxH7A HT 72-156(M/P) Peimar SGxxxM(FB/BF) Vikram Eldora,Solivo,Somera Hyundai KG,MG,TG,RI,RG,TI,MI,HI &KI Series ' Phono Solar PS-60,PS-72 Waaree AC&Adiya Series ITEK IT,IT-HE&IT-SE Series Plus,Pro,Peak,G3,G4,G5,G6(+),G7,G8(+) Winaico WST&WSP Series Japan Solar JPS-60&JPS-72 Series Q.Cells Pro,Peak L-G2,L-G4,L-G5,L-G6,L-G7 Yingli YGE&YLM Series Please see the SFM UL2703Construction Data Report at Unirac.com to ensure the exact solar module selected is approved for use with SFM. SFM Infinity is not compatible with module frame height of less than 32mm and more than 40mm. See page 1 for further information. • structu ra I Attachment shall be staggered where ground snow load exceeds 10 PSF. ENGINEERS July 1,2020 Testing: Values were based on UTR-299 testing provided by Unirac. Unirac Components and Cladding Roof Zones: 1411 Broadway Blvd.NE The Components and Cladding Roof Zones shall be determined based on ASCE 7-05,ASCE 7-10&7-16 Component and Albuquerque,NM 87102 Cladding design. Notes: 1)U-builder Online tool analysis is only for Unirac SFM Sunframe Microrail system only and do not Attn.:Unirac-Engineering Department include roof capacity check. Re:Engineering Certification for the Unirac Sunframe Microrail,SFM Infinity U-builder Software 2)Risk Category II per ASCE 7-16. 3)Topographic factor,kzt is 1.0. PZSE,Inc.-Structural Engineers has reviewed the Unirac's Sunframe Microrail,proprietary mounting system constructed 4)Array Edge Factor YE=1.5 from modular parts which is intended for rooftop installation of solar photovoltaic(PV)panels;and has reviewed the U- 5)Average parapet height is 0.0 ft. builder Online tool.This U-Builder software includes analysis for the 2"Microrail,8"Attached Splice,6"splice,and front 6)Wind speeds are LRFD values. trimrail. All information,data and analysis contained within are based on,and comply with the following codes and 7)Attachment spacing(s)apply to a seismic design category E or less. typical specifications: Design Responsibility: 1. Minimum Design Loads for Buildings and other Structures,ASCE/SEI 7-05,ASCE/SEI 7-10,ASCE/SEI 7-16 The U-Builder design software is intended to be used under the responsible charge of a registered design professional 2. Massachusetts State Building Code,780 CMR 9th Edition. where required by the authority having jurisdiction.In all cases,this U-builder software should be used under the 3. 2006-2018 International Building Code,by International Code Council,Inc.w/Provisions from SEAOC PV-2 2017. direction of a design professional with sufficient structural engineering knowledge and experience to be able to: 4. 2006-2018 International Residential Code,by International Code Council,Inc.w/Provisions from SEAOC PV-2 • Evaluate whether the U-Builder Software is applicable to the project,and 2017. 5. AC428,Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic(PV)Panels,November • Understand and determine the appropriate values for all input parameters of the U-Builder software. 1,2012 by ICC-ES. This letter certifies that the Unirac SFM Sunframe Microrail,when installed according to the U-Builder engineering Following are typical specifications to meet the above code requirements: report and the manufacture specifications,is in compliance with the above codes and loading criteria. Design Criteria: Ground Snow Load=0-100(psf) This certification excludes evaluation of the following components: Basic Wind Speed=90-180(mph) 1) The structure to support the loads imposed on the building by the array;including,but not limited to:strength Roof Mean Height=0-30(ft) and deflection of structural framing members,fastening and/or strength of roofing materials,and/or the effects Roof Pitch=0-45(degrees) of snow accumulation on the structure. Exposure Category=B,C&D 2) The attachment of the SFM 2"Microrail or 8"Attached Splice to the existing structure. Attachment Spacing: Per U-builder Engineering report. 3) The capacity of the solar module frame to resist the loads. Cantilever: Maximum cantilever length is L/3,where"L"is the span noted in the U-Builder online This requires additional knowledge of the building and is outside the scope of the certification of this racking system. tool. Clearance: 2"to 10"clear from top of roof to top of PV panel. If you have any questions on the above,do not hesitate to call. Tolerance(s): 1.0"tolerance for any specified dimension in this report is allowed for installation. Prepared by: Installation Orientation: See SFM Installation Guide. Roseville,CA PZSE,Inc.—Structural Engineers •' �SN oF6fg9 PAUL K. Landscape-PV Panel long dimension is parallel to ridge/eave line of roof and the PV r; ZACHER panel is mounted on the long side. STRUCTURAL y Portrait-PV Panel short dimension is parallel to ridge/eave line of roof and the PV panel ` . DIo.X0190 is mounted on the short side. • 06 ao z ' �SS/oNA6elG, 1478 Stone Point Drive,Suite 190, Roseville,CA 95661 7 916.961.3960 1 916.961.3965 V; www.pzse.com hteg>ityf En- ,: <c.i'i3nt r a , , r , , . . tnter-tek AUTHORIZATION TO MARK (ntertek AUTHORIZATION TO MARK • Total Quality.Assured. Total Quality.Assured. "This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) ? This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing i Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing ' { Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing G ' I Report. Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be `applied only at the location of the Party Authorized To Apply Mark. applied only at the location of the Party Authorized To Apply Mark. Applicant: Unirac,Inc Manufacturer: Applicant: Unirac, Inc Manufacturer: 1411 Broadway Blvd NE — — 1411 Broadway Blvd NE Address: Address:Albuquerque,NM 87102 Address: Albuquerque,NM 87102 Address: Country: USA Country: Country: USA Country: Contact: Klaus Nicolaedis Contact: Contact: Klaus Nicolaedis Contact: — — Todd Ganshaw Todd Ganshaw Phone: 505-462-2190 Phone: —.___ , Phone: 505-462-2190 Phone: 505-843-1418 505-843-1418 FAX: NA FAX: FAX: NA FAX: — Email: klaus.nicolaedis@unirac.com Email Email: klaus.nicolaedis@unirac.com Email: toddg@unirac.com toddg@unirac.com Party Authorized To Apply Mark: Same as Manufacturer Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest,CA Report Issuing Office: Lake Forest,CA • ��77 Control Number: 5003705 Authorized by: ctotit4Ar161Control Number: 5014989 Authorized by: ciouvia; for L.Matthew Snyder,Certification Manager for L.Matthew Snyder,Certificati n Manager 1 COUSk C US ArmCO k \-._._.___..._ Intertek _._ Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client Intertek's responsibility and liability are This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client.Intertek's responsibility and liability ere limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned limited to the terms and conditions of the agreement Intertek assumes no liability to any party,other than to the Client In accordance with the agreement,for any toss,expense or damage occasioned by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in Its entirety.Use of Intertek's Certification mark is by the use of this Authorization to Mark.Only the Client Is authorized to pent copying or distribution of this Authorization to Mark and then only In its entirety.Use of Intertek's Certification mark is restricted to the conditions laid out In the agreement end in this Authorization to Mark Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must restricted to the conditions laid out In the agreement and In this Authorization to Mark.Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must first be approved In writing by Intertek Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark In accordance with the first be approved In writing by Intertek Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification nark In accordance with the agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect agreement.they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect Intertek Testing Services NA Inc. Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights,IL 60005 545 East Algonquin Road,Arlington Heights,IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems,Mounting Devices,Clamping/Retention Devices,and Ground Lugs for Use with Flat- Mounting Systems,Mounting Devices,Clamping/Retention Devices,and Ground Lugs for Use with Flat- Standard(s): Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed.1] Standard(s): Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed.1] Photovoltaic Module Racking Systems[CSA LTR AE-001:2012 Ed.2012/10/23] Photovoltaic Module Racking Systems[CSA LTR AE-001:2012 Ed.2012/10/23] Product: Photovoltaic Mounting System,Sun Frame Microrail Installation Guide,PUB2020MAY04 Product: Photovoltaic Mounting System,Sun Frame Microrail Installation Guide,PUB2020MAY04 Brand Name: Unirac Brand Name: Unirac Models: Unirac SFM Models: Unirac SFM ' ATM for Report 102393982LAX-002 Page 1 of 2 ATM Issued:2-Jun-2020 ATM for Report 102393982LAX-002 Page 2 of 2 ATM Issued:2-Jun-2020 ED 16.3.15(20-Apr-17)Mandatory ED 16.3.15(20-Apr-17)Mandatory