HomeMy WebLinkAbout50 Park Ave plan 540'-1"
20'-44„
BEAM POCKET
(IF REQUIRED)
I�
I
�2 \6
BEAM POCKET
(IF REQUIRED)
o a CRAWL SPACE00 i
i�
HSS 3 1/2"x 3 1/2"
3'-0" i x 3/8" COLUMN t
I
I E
I-- 3' 6" --I I BEAM POCKET--//
-i (IF REQUIRED)
12'-24" 15-94,,
� � f
I
�
MIN. 18"X24" o , 1
ACCESS/VENT OPENIN
HSS 3 1/2% 3 1/2"
i x 3/8" COLUMN
i
ENCLOSURE ENCLOSURE
N0.2 I NO.1
1n 19 -1 14" 15'-94"
N
0
t
(o 03 1/2" CONCRETE FILLED
CRAWL SPACE 02 , 6 (` STEEL LALLY COLUMN (TYP.)
USE SIMPSON COLUMN CAPS
CRAWL SPACE AND COLUMN BASES ,l
FOR CONNECTIONS
N
7'-82" 12'-24" 15'-94"
Lo
,
BEAM POCKET
-(IF REQUIRED)
11
110
/.- 02'-6"
MINIMUM VERTICAL REINFORCEMENT FOR 10-INCH NOMINAL
FLAT CONCRETE BASEMENT WALLS
MINIMUM VERTICAL REINFORCEMENT - BAR SIZE IN
SPACING (INCHES)
MAXIMUM
UNSUPPORTED
WALL HEIGHT
MAXIMUM
UNBALANCED
BACKFILL
SOIL CLASSES AND DESIGN LATERAL SOIL
(PSF PER FOOT OF DEPTH)
GW, GP, SW, SP
30
GM, GC, SM,
SM-SC, ML
45
SC, ML-CL,
INORGANIC CL
60
FT
FT
4
NR
NR
NR
5
NR
NR
NR
6
NR
NR
NR
8
7
NR
NR
NR
8
6@48
6@35
6@28
4
NR
NR
NR
5
NR
NR
NR
6
NR
NR
NR
9
7
NR
NR
NR
8
NR
NR
6@31
9
6@37
6@28
6@24
4
NR
NR
NR
5
NR
NR
NR
6
NR
NR
NR
10
7
NR
NR
6@28
8
NR
6@28
6@24
9
6@33
6028
6@21
10
6@28
6@23
6@17
MINIMUM HORIZONTAL REINFORCEMENT FOR
CONCRETE BASEMENT WALLS
MAXIMUM
UNSUPPORTED
WA__L HEIGHT
LOCATION OF HORIZONTAL REINFORCEMENT
FT
<8
-
ONE #4 BAR WITHIN 12 INCHES OF THE TOP OF THE WALL STORY AND
ONE #4 BAR NEAR MID -HEIGHT OF THE WALL STORY
>8
ONE #4 BAR WITHIN 12 INCHES OF THE TOP OF THE WALL STORY AND
ONE #4 BAR NEAR THIRD POINTS OF THE WALL STORY
4"
35'-9"
40'-1"
4"
110
FO UNDA TIO N PLAN
FIN. FL.
2x6 CONT.
lb
9' -24"
o1'-0"
MIN. 1 11
X24",
ACCES /VENT OPENING r�
SIMPSON COLUMN
BASE (TYPICAL)
FINISHED GRADE
012" SONOTUBE FOUNDATION
WITH 30" BELL
MIN 3,500 psi CONCRETE
BEAMS
(SEE FRAMING PLAN)
-SIMPSON COLUMN
CAP TYPE CC
(TYPICAL)
-6"x6" PRESSURE
TREATED COLUMN
00
12" z
N
30"
UNLESS
OTHERWISE
NOTED
TYPICAL DECK FO UNDA TIO N
DETAIL
SCALE: NTS
24" MIN.
i 12" !
° D
7, Z
D N
N
D °
#4 @ 12" O.C.
NEW CONCRETE
WALL
CORNER REINFORCEMENT
TYPICAL DETAIL
SCALE: NTS
ANCHOR BOLTS
TYPICAL SILL DETAIL
SCALE: NTS
FLOOR JOISTS
LI Z FLOOR JOISTS R-20 FIBER BUTT INSULATION
2x6 P.T. CONT. (SEE FRAMING PLANS;' WITH 4 MIL POLY
00
MIN 1 /2" 0 ANC. VAPOR BARRIER
BOLTS @ 32 JOIST HANGERS �'-----AM (SEE FRAMING PL.!;NS)
FIN. GRADE PRESSURE TREATED SILL
- - - 3 1 /2"0 COL.
- PROVIDE 01/2"x12" LONG
ANCHOR J-BOLTS
_\/:J��-#4 @18" (MODIFY PER NOTE AND TABLE) -- "------ @ MAX 6 FT O.C. -�
#4 @18" (MODIFY PER NOTE AND TABLE) °'--- z
III
DAMP PROOFING11, 5/8„0 x 10' LON o _,-�
ANCHOR BOLTS „I w �� GRADE \
�'zo
1 /2" BASE PLATE ? o 0
d- u I L1oz0 =
z_ REINF. 6x6-10/10 WELDED z 0
� WIRE FABRIC. i [ - �E - _-ONSITRUCTION � 0
#4 @48" DOWELS ` 0
R-10 RIGID INSULATION - m
OPTIONAL x A x ° Xe .4 XI_x
�- -
X 4 .aX X X ' xK X:
A
° v00011
ib Ml
COMPACTED
GRANULAR FILL `-
6 MIL P 0 LY
FOUNDATION NOTES:
A. GENERAL: (UNLESS OTHERWISE NOTED)
1.) ALL WORK SHALL CONFORM WITH THE MASS. STATE BUILDING CODE, TOWN OF WEST YARMOUTH ZONING BY LAWS, AND ALL
APPLICABLE OSHA STANDARDS.
2.) ANY WOOD FRAMING MEMBERS IN DIRECT CONTACT WITH CONCRETE SURFACES SHALL BE COATED WITH PRESERVATIVE.
3.) ALL FOUNDATION WALLS SHALL BE BRACED DURING THE OPERATIONS OF BACKFILLING AND COMPACTION. BRACING SHALL BE LEFT IN
POSITION UNTIL PERMANENT RESTRAINTS HAVE BEEN INSTALLED.
4.) CONCRETE WALLS TO BE DAMPPROOFED BELOW GRADE, EXTERIOR SIDE. LOCAL BUILDING DEPARTMENT SHALL INSPECT EXCAVATION
PRIOR TO CONSTRUCTION OF FOOTING AND WALLS, AND AT OTHER INTERVALS IN ACCORDANCE WITH LOCAL STANDARD PRACTICES.
5.) IF THE CONTRACTOR MAKES ANY CHANGES OR DEVIATES FROM THE CONTRACT DOCUMENTS WITHOUT WRITTEN APPROVAL FROM THE
ENGINEER, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE TOTAL DESIGN.
6.) SLAB POURED ON GROUND SHALL REST AGAINST 6" COMPACTED SAND ON 1 LAYER OF POLYETHYLENE SHEETING (6 MILS).
B. FOUNDATION REQUIREMENTS:
1.) THE BOTTOM OF FOOTINGS SHALL BEAR ON UNDISTURBED INORGANIC GRANULAR SOIL OR COMPACTED STRUCTURAL FILL WITH A
SAFE ALLOWABLE BEARING PRESSURE OF MINIMUM 2 TONS/SQ FT.
2.) IF ORGANICS ARE ENCOUNTERED IN THE EXCAVATION, WORK SHALL BE SUSPENDED AND THE ENGINEER CONTACTED PRIOR TO
COMMENCING WORK.
3.) CONCRETE SHALL BE PLACED "IN THE DRY" ONLY, AND NO CONCRETE SHALL BE PLACED ON FROZEN GROUND.
4.) SPECIAL CARE SHALL BE TAKEN IN BACKFILLING WALLS AND UTILITY TRENCHES. BACKFILL MATERIAL SHALL BE COMPACTED IN 12"
LAYERS MAXIMUM WITH POWER TAMPERS OR BY OTHER APPROVED EQUIPMENT.
5.) WALLS RETAINING EARTH SHALL BE BACKFILLED EQUALLY EACH SIDE UNLESS ADEQUATELY BRACED.
C. CONCRETE: (UNLESS OTHERWISE NOTED)
1.) CONCRETE WORK SHALL CONFORM TO THE LATEST AMERICAN CONCRETE INSTITUTE BUILDING CODE, STANDARDS, RECOMMENDED
PRACTICES AND SPECIFICATIONS AS REVISED TO DATE.
2.) CONCRETE SHALL BE MIXED IN THE SPECIFIED PROPORTIONS TO GIVE MINIMUM COMPRESSIVE STRENGTH AT THE END OF 28 DAYS
OF 3500 PSI.
3.) CONSTRUCTION JOINTS IN STRUCTURAL CONCRETE SHALL BE LOCATED IN THE MIDDLE THIRD OF THE SPAN OR OTHER APPROVED
LOCATION OF MINIMUM SHEAR.
D. REINFORCING STEEL: (UNLESS OTHERWISE NOTED)
1.) BARS SHALL BE HIGH BOND DEFORMED BARS MEETING ASTM A-615, GRADE 60.
2.) WHERE OPENINGS OCCUR IN WALLS OR SLABS, PROVIDE 2 - #4 EACH FACE EACH SIDE OF OPENINGS AND EXTEND 2'6"
BEYOND OPENING.
3.) SLABS ON GRADE SHALL BE REINFORCED WITH 6x6-W10xW10 WELDED WIRE FABRIC. LAP CROSS WIRES ONE SPACE PLUS 2"
ALL SIDES.
E. MISCELLANEOUS: (UNLESS OTHERWISE NOTED)
1.) VERIFY IN FIELD ALL LOCATIONS AND CONDITIONS IN THE STRUCTURE SHOWN ON THE DRAWINGS AND/OR AFFECTING THE
INSTALLATION OF NEW WORK. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE FABRICATION OF
DEPENDENT WORK.
2.) IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ADEQUATE SHORING AND BRACING TO SAFELY SUPPORT THE BUILDING
DURING CONSTRUCTION. ANY APPROVAL BY THE ENGINEER WILL NOT RELIEVE THE CONTRACTOR OF FULL RESPONSIBILITY, FOR
SHORING AND/OR BRACING.
3.) DURING THE CONSTRUCTION PHASE OF THE PROJECT THE CONTRACTOR SHALL REVIEW DESIGN LOADS TO LIMIT AND CONTROL
CONSTRUCTION LOADING, INCLUDING BUT NOT LIMITED TO MATERIAL STOCK PILING AND CONSTRUCTION EQUIPMENT.
R322.2_2 ENCLOSED AREA BELOW DESIGN FLOOD ELEVATION.
ENCLOSED AREAS, INCLUDING CRAWL SPACES, THAT ARE BELOW THE DESIGN FLOOD ELEVATION AND BASEMENTS
SHALL:
1. BE USED SOLELY FOR PARKING OF VEHICLES, BUILDING ACCESS OR STORAGE.
2- BE PROVIDED WITH FLOOD OPENINGS THAT MEET THE FOLLOWING CRITERIA AND ARE INSTALLED IN
ACCORDANCE WITH
SECTION R322.2.2.1: 9TH EDITION RESIDENTIAL VOLUME WITH MA AMENDMENTS - FLOOD STANDARDS ONLY
2.1. THE TOTAL NET AREA OF OPENINGS SHALL BE NOT LESS THAN ONE IN2 (645 MM2 ) FOR EACH
FT2 (0.093 M2 ) OF
ENCLOSED AREA WHERE THE ENCLOSED AREA IS MEASURED ON THE EXTERIOR OF THE ENCLOSURE WALLS, OR
THE OPENINGS SHALL
BE DESIGNED AS ENGINEERED OPENINGS AND THE CONSTRUCTION DOCUMENTS SHALL INCLUDE A STATEMENT BY
A REGISTERED DESIGN
PROFESSIONAL THAT THE DESIGN OF THE OPENINGS WILL PROVIDE FOR EQUALIZATION OF HYDROSTATIC FLOOD FORCES
ON EXTERIOR
WALLS BY ALLOWING FOR THE AUTOMATIC ENTRY AND EXIT OF FLOODWATERS AS SPECIFIED IN SECTION 2.6.2.2
OF ASCE 24.
2.2. OPENINGS SHALL BE NOT LESS THAN THREE INCHES (76 MM) IN ANY DIRECTION IN THE PLANE
OF THE WALL.
R322.2.2.1 INSTALLATION OF OPENINGS.
THE WALLS OF ENCLOSED AREAS SHALL HAVE OPENINGS INSTALLED SUCH THAT:
1. THERE SHALL BE NOT LESS THAN TWO OPENINGS ON DIFFERENT SIDES OF EACH ENCLOSED AREA;
IF A BUILDING HAS
MORE THAN ONE ENCLOSED AREA BELOW THE DESIGN FLOOD ELEVATION, EACH AREA SHALL HAVE OPENINGS ON
EXTERIOR WALLS.
2. THE BOTTOM OF EACH OPENING SHALL BE NOT MORE THAN ONE FOOT (305 MM) ABOVE THE HIGHER
OF THE FINAL
INTERIOR GRADE OR FLOOR AND THE FINISHED EXISTING EXTERIOR GRADE IMMEDIATELY UNDER EACH OPENING.
3. OPENINGS SHALL BE PERMITTED TO BE INSTALLED IN DOORS AND WINDOWS; DOORS AND WINDOWS
WITHOUT INSTALLED
OPENINGS DO NOT MEET THE REQUIREMENTS OF THIS SECTION.
FINISHED FLOOR
VAPOR BARRIER
LIZs
w
zzO0
;7b"
�= <0
�T
AREA OF FLOOD ZONE OPENINGS IN THE FOUNDATION WALLS CALCULATION:
AREA
TOTAL AREA OF
NUMBER OF
NUMBER OF
ENCLOSURE
(S.F.)
FLOOD OPENINGS
FLOOD
OPENINGS
FLOOD
OPENINGS
(S.IN.)
(12 INx12 IN)
(12 INx12 IN)
RQUIERED
PROVIDED
NO.1
1093.1
1093.1
7.59
8
N0.2
191.7
191.7
1.33
4
R-30 FOAM INSULATION
i 2" RAT SLAB WITH VAPOR BARRIER
- #4 REINFORCEMENT BARS, GRADE 60 @ 36" O.C.
BOTH DIRECTIONS
3 - #4 REINFORCEMENT BARS
2" MIN CLEAR COVER
TYPICAL CRAWL SPACE FOUNDATION
3-#4 CONT. VAPOR BARRIER ° 2 -0'"x2 -0" ^ -#4 EW.
#4 @12" 2 COMPACTED UNLESS SCALE: NTS r
(RANII II AR FII I OTHERWISE
FOOTING �, NOTED
_4
TYPICAL FOUNDATION DETAIL TYPICAL COLUMN FO UNDA TI('),NT DETAIL
SCALE. NTS NOTE: SCALE: NM
REFER TO IRC 2015;
TABLES R404.1.2(4), AND R404.1.2(9) FOR VERTICAL REINFC__- '':_%'- M'EQUIREIMENT;, AND
TABLES R404.1.2(1) FOR HORIZONTAL REINFORCEMENT REQU1==
NOTE:
REFER TO IRC 2015;
TABLES R404.1.2(4), AND R404.1.2(9) FOR VERTICAL REINFORCEMENT REQUIREMENT;
AND TABLES R404.1.2(1) FOR HORIZONTAL REINFORCEMENT REQUIREMENTS)