TEST PIT TP-1
GIRD. EL. 11.6
SHGW EL 1.6
EL. 10.8
EL 10.3
EL. 9.5
EL. 1.6
NOT TO
A
SL
1OYR 2/1
B1
LS
1OYR 5/8
B2
LS
1OYR 7/4
C
MS
1OYR 8/2
NO
GROUNDWATER
OBSERVED
REMOVABLE
COVER
10"
16"
120"
6" MAX.
HDPE RISER
2" WALLS 3"
..d : 7.
9-1/2" 0
11-1 /2"
e
2" ,
BOTTOM ON LEVEL 6" MINIMUM
STABLE BASE 3/4' TO 1-1/2"
CRUSHED STONE
DATE:
JANUARY 12, 2022
TEST BY:
BSC GROUP, INC.
WITNESSED BY:
PHIL RENAUD
LICENSED SOIL EVALUATOR:
TODD MACDONALD
PERCOLATION RATE:
< 2 MINS./INCH
SOIL CLASS:
CLASS 1
L.T.A.R.:
0.74 GPD/S.F.
LEGEND
UNSUITABLE
MATERIALS
(TO BE REMOVED)
sm
DN
PERCOLATION v_ ESTIMATED
DOd TEST RANGE - SEASONAL HIGH
GROUNDWATER
21"
1
1 �•
DIA.
13" KNOCKOUTS
TYP. I
I
1 la
.1 1.
3
1. PROVIDE INLET TEE OR BAFFLE WHERE SLOPE OF PIPE EXCEEDS 0.08 FT./FT OR
IN PUMPED SYSTEM.
E
`' 2. FIRST TWO FEET OF PIPE OUT OF DIST. BOX TO BE LAID LEVEL.
� 3. ALL PIPE CONNECTIONS .AND CONCRETE CONSTRUCTION SHALL BE WATERTIGHT.
v
4. FILL ALL UNUSED KNOCKOUTS WITH MORTAR.
5. CONCRETE COVER SHALL BE RAISED TO WITHIN 6 INCHES OF FINISHED GRADE.
n
SIGN
CALCULATIONS
i
kf
E DESIGN FLOW EXISTING
& PROPOSED
s 4 BEDROOMS 0 110
GPD/BEDROOM = 440 GPD
REQUIRED SEPTIC TANK
Aj
440 GPD X 200%
= 880 GALLONS
0 USE 1,500 GALLON
SEPTIC TANK
.4 TGRIMMM111
DESIGN PERC. RATE: <2 MIN/INCH
i LONG TERM APPL RATE: 0.74 GPD/SF
:v 440 GPD : 0.74 GPD/SF = 595 SF
14
14 SIZE -OE LEACHING FACILITY PROVIDED
USE (4) 500 GALLON H-20 CONCRETE LEACHING CHAMBERS IN TRENCH
CONFIGURATION WITHIN 10' X 40' STONE FIELD.
BOTTOM AREA: 40' X 10' = 400 S.F.
SIDEWALL AREA: 2 X (2 X (40' + 10')) = 200 S.F.
EFFECTIVE LEACHING AREA = 600 S.F.
CL 600 S.F. X 0.74 GPD/S.F. = 444 GPD (INSTALLED CAPACITY)
444 GPD > 440 GPD (4 GPD RESERVE CAPACITY PROVIDED)
a_
w
V)
I 1 2500 GALLON SEPTIC TANK
3 NOT TO SCALE
Ln
n
n 1. SEPTIC TANK SHALL BE STEEL REINFORCED CONCRETE.
0
2. SEPTIC TANK SHALL BE CAPABLE OF WITHSTANDING H-10
w LOADING.
rn 3. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION
c
3 SHALL BE WATERTIGHT.
of 4. TEES SHALL BE SCH. 40 PVC AND SHALL BE LOCATED
�. WITHIN 12" OF TANK WALL AND ACCESSIBLE FROM TANK
1.) TO ALLOW A LEACHING AREA TO BE 3' AWAY FROM A
COASTAL BANK IN LIEU OF 50'. A 47' VARIANCE IS REQUESTED.
2.) TO ALLOW A SEPTIC TANK TO BE 15' AWAY FROM A COASTAL
f ,
NOT TO SCALE
4" PERFORATED PVC 20" ACCESS COVER & SCOTT SCHUMACHER
W/SCREW CAP TO EXTEND DOWN TO WITHIN 3 INCHES TITLE REFERENCE: BOOK 32858, PAGE 286
TO NATURAL SUBGRADE OF FINISH GRADE
LOAM AND SEED PLAN REFERENCE: BOOK 276, PAGE 77
5" DIA. KNOCKOUT (TYP.) ALL DISTURBED AREAS
1-1/2" TAPER° / / , ' , . ASSESSORSPARCEL: 73
CONC. 12-36" COVER
RISER ZONING DISTRICT: R-25
2" LAYER OF 1/s" To SETBACKS: FRONT 30'
1 /2" DOUBLE WASHED
STONE ABOVE CROWN SIDE 15
36" 24" ® OF PIPE REAR 20'
'!
EFFECTIVE ® ® 3/4" TO 1-1/2- OVERLAY DISTRICT: NONE
DEPTH s ® ® ® DOUBLE WASHED NITROGEN SENSITIVE
STONE TO CROWN ZONE: NOT IN A ZONE 11
�OF PIPE -�-- 8'-6" 4'-10" FEMA FLOOD -
ZONE DISTRICT: "AE EL.=11 & X", DATED 7/16/14
FRONT VIEW 10'-0"-1 PANEL #25001 CO569J
NOTESIDE VIEW MINIMUM LOT SIZE: 25,000 S.F.
S:
1. ONE ACCESS COVER PER SYSTEM SHALL BE RAISED TO FINISH GRADE. EXISTING LOT SIZE: 14,650t S.F.
2. CHAMBERS SHALL BE 500 GALLON LEACHING DRYWELL, MANUFACTURED BY SHOREY OR APPROVED EQUAL. EXISTING BUILDING COVERAGE: 2,076t S.F. (14.2%)
3. GEOTEXTILE FABRIC MAY BE USED IN LIEU OF DOUBLE WASHED STONE.
PROPOSED BUILDING COVERAGE: 2,016t S.F. (13.8%)
BANK IN LIEU OF 25. A 10 VARIANCE IS REQUESTED.
OVERGROWN
TOWN OF YARMOUTH
NONE BOG �'� a04
W #103
-
w #100 PF 1 3 -. _ _ 0 "ETLAN Y
.,_ - w--•-.. ..w_...,___,.,.,,,,__ .,.-,,,,,,,"'"""✓" NIA•
„-.
MAP 20
PARCEL 58.1.1
i
Ea4`
� I
' E
yx�
ATES & ELIZASE1H CIV tQ ' r
& SCOTT SCHUMACITER
MAP 20'o
PARCEL 'L 73
CARAFE "iM, 676# SF.
_IF
�
KATr ALE to"., AR AS 41 `:> PROPOSER
MAP 20 DRYWELL
? f j s^ VF 203
of 7
op or
CO,AS. s
RAISE AT LEAST ONE EXISTING COVER
TO WITHIN 6' OF FINISHED GRADE
THE RISER SHALL BE 18" HDPE PIPE
6" MAX. r CONC. COVER
COVER.
5. FILL ALL UNUSED KNOCKOUTS WITH HYDRAULIC CEMENT. 4"
o
Ln 10'-6"Lo
d
o
10'-0" _
10"
3"
co
4' MIN. "
LIQUID 5-8
s 4'-6" LOCATE
TEE DEPTH
INLET 4
a 5'-8" UNDER COVER OUTLET TEE
_ _ - W/GAS BAFFLE 3"
I a
E 6" MINIMUM CROSS-SECTION VIEW
z PLAN VIEW 3/4" TO 1-1/2"
CRUSHED STONE
OVERGROWN
BOG
Able
11•
�%
IUD �- � � ` � � � W '':�Ci4
0 �Tt A FLOOD
EFER VENTS
s. st ISTONE
BENCHMARK • BOUNDCONC. BOUND( F"ND
W DISK z
ELEV = Z21
'� _
a TOF=12.0 APPROIA TE
3S 9 CRAWL 9 5 I s LO A77ON OF
EIS7INC SEP77C
POP. I(OUT)=9.6
11.5
PROPOSED
6 S
S
DRYWELL
PROPOSED 1,500
IE
GALLON SEPTIC TANK
" s
y
Q; ,� H LANt`bTOT
I(IN) =9.30
Y .T }.
�;
\
112
TP-1 MAP 20
EL.11.6 <PARCEL 74
I(OUT)=9.05
5' OVERDIG
� <.
/0
f03 g
,t
BREAKOUT
LINER ° `�
TOP EL.=9.65
�••`
(4) 500-GALLON CONC.
BOT. EL.=6.65 .5
LEACHING CHAMBERS
TOP CHAMBERS=9.65
INV.=8.65
°h
BTM CHAMBERS=6.65
DIST. BOXe
I(IN)=8.99
I(OUT)=8.82
SLAB
GENERAL NOTES
1. THIS PLAN IS INTENDED FOR THE PERMITTING AND CONSTRUCTION OF THE SEWAGE
DISPOSAL SYSTEM AND ASSOCIATED SITE WORK.
2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO 310 CMR 15.000
AND YARMOUTH BOARD OF HEALTH REGULATIONS.
3. THERE ARE NO KNOWN OR PROPOSED PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE
PROPOSED LEACHING FACILITY.
4. IF AN OVERDIG IS SPECIFIED, REMOVE ALL TOPSOIL, SUBSOIL AND OTHER UNSUITABLE
MATERIALS.
5. IF AN OVERDIG IS SPECIFIED, REPLACE ALL EXCAVATED MATERIALS WITHIN THE LIMIT OF
EXCAVATION WITH CLEAN GRANULAR SAND, FREE FROM ORGANIC MATERIAL AND
DO ETRIOUS SUBSTANCES. MIXTURES AND LAYERS OF DIFFERENT CLASSES OF SOIL
SHALL NOT BE USED. FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN 2
INCHES. A SIEVE ANALYSIS USING A #4 SIEVE SHALL BE PERFORMED ON A
REPRESENTATIVE SAMPLE OF FILL. UP TO 45% BY WEIGHT MAY BE RETAINED ON THE
#4 SIEVE. SUCH ANALYSES MUST DEMONSTRATE THAT THE MATERIAL MEETS EACH OF
THE FOLLOWING SPECIFCA11ONS:
100% MUST PASS #4 SIEVE
10% MUST -ASS #50 SIEVE
0-20% MUST PASS #100 SIEVE
0-57. MUST PASS #200 SIEVE
6. EXISTING UTILITIES WHERE SHOWN ON THE PLANS ARE APPROXIMATE. THE ENGINEER
DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL SUBSURFACE STRUCTURES ARE
SHOWN. CONTRACTOR SHALL VERIFY THE SIZE, LOCATION AND ELEVATION OF INVERTS
OF UTILITIES AND STRUCTURES, WITHIN THE LIMIT OF WORK, PRIOR TO THE START OF
CONSTRUCTION. IF ANY DISCREPANCIES ARE DISCOVERED OR FIELD CHANGES REQUIRED,
THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY.
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY COORDINATING THE
PROPOSED CONSTRUCTION ACTIVITIES WITH DIG -SAFE AND THE APPLICABLE UTILITY
COMPANIES, AND SHALL COMPFiETE THE PROPOSED WORK WITHOUT ANY INTERRUPTIONS
IN SERVICE.
8. CONTRACTOR IS REQUIRED TO NOTIFY DIG -SAFE, PER MASS. STATUTE CHAPTER 82,
SECTION 40 (1-888-344-7233) A MINIMUM OF 72 HOURS PRIOR TO THE START OF
CONSTRUCTION.
9. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. INSTALLATION
OR USE OF A GARBAGE GRINDER AT THIS PROPERTY IS NOT ALLOWED PER 310 CMR
15.240(4).
NOTES:
1.) ENGINEER TO CERTIFY SOIL REMOVAL PRIOR TO
SEPTIC INSTALLATION AND A FINAL INSPECTION AFTER
THE SYSTEM IS INSTALLED_
2.) AS THIS IS A REPLACEMENT OF A 4 BEDROOM
DWELLING WITH A 4 BEDROOM DWELLING 1T IS NOT
CONSIDERED AN INCREASE IN SEPTIC FLOW AND A
RESERVE AREA IS NOT DEPICTED.
NOT TO SCALE
EL:=12.00
TOP FOUNDATION
EL. 11.3t 4" SCH. 40 PVC
�L=10± FT.
5=0.03
?11111451 /Z-
4" SCH. 40 PVC
L=6 FT.
S__0.01
-FIRST PIPE LENGTH
TO BE SET LEVEL FINISH GRADE
FOR MIN. 2' 11.2-11.4
BREAKOUT LINER
i- 4" SCH. 40 PVC TOP EL=9 65
1=9.05 �--�
I=9.30 1=8.99
,i3 DISTRIBUTION
NOTE* SEPTIC TANK BOX
MAGNETIC REFLECTIVE TAPE SHALL BE PROVIDED
IN THE TRENCH OVER ALL PVC PIPING
BOT. EL.=6.65
El- 9.65
0 0 0 0 0 C3 o o a
0 0 o n o o e= o 0 0
1.65 0 0 0 0 0 0 0 0 0 0
EL 6.65
LEACHING
5.05' SEPARATION CHAMBERS
ELEV= 1.6
ESTIMATED S.H.G.W. (BOTTOM OF TEST PIT)