HomeMy WebLinkAbout657 Willow St plan 1F_
STAMP:
Y
NOV 15 2022
GENERAL NOTES (See also Project Specifications):
1. The General Conditions state that the Contract Documents are complimentary.
2. Provide the services of a Massachusetts Registered Surveyor to layout structure on site
and establish existing elevations. Elevation of finished floor shall be established by
Architect With elevation information provided by Surveyor.
3, The General Contractor is responsible for all the Work.
A. Build and install parts of the Work level, plumb, square and in correct position.
B. Make joints tight and neat, If such is impossible, apply moldings, sealant or other
joint treatment as directed by Architect.
C. Under potentially damp conditions, provide galvanic insulation between different
metals Which are not adjacent on the galvanic scale.
D. Apply protective finish to parts of the Work before concealing them. For example,
paint door tops, bottoms, glazing stops, glazing rebates, and hardware cutouts before
hanging doors, and paint corrodible mounting plates before installing parts over them.
E. Where accessories are required in order to install parts of the Work in usable form
and to make the Work perform properly, provide such accessories. If special tools
are required to maintain, adjust and repair products, provide them.
F. Follow manufacturer's instructions for assembling, installing and adjusting products.
Do not install products in a manner contrary to the manufacturer's instructions
unless authorized in Writing by the Architect.
G. Adjust and operate oil items of equipment, leaving them fully ready for use.
H. The division of the Documents into Architectural, Structural, Electrical, Mechanical,
Plumbing and Civil components is not intended as division of the Work by trade or
otherwise.
I. Provide utility installations from lot line to house including underground electrical,
Water, telephone and CATV to comply With all local codes and requirements.
J. Concrete shall have compressive strength of 3000 psi @ 28 days for Walls and
3500 psi @ slab Work, and reinforcing rods & Woven Wire fabric (WWF) per drawings.
Where noted, provide hard steel trowel finish on slabs.
Dompproofing shall be factory manufactured semi -mastic consistency from asphalts
and mineral fibers, and installed on all Wails and footings.
Piers for decks shall be concrete filled Sonotube forms.
4. The General Contractor shall verify all dimensions at the site and shall notify the
Architect of any discrepancies before proceeding With the Work or purchasing moterials
or equipment. Verify critical dimensions in the field before fabricating items Which must
fit adjoining construction.
5. All details are typical unless otherwise noted and are not necessarily shown in the
Documents at all locations Where they occur.
6. The Architectural Documents govern the location of all Electrical and Mechanical items
installed as a part of the Work.
7. Existing items Which are not to be removed and are damaged or removed in the course
of the Work shall be repaired and replaced in like new condition Without cost.
9DDITION/REN0V4TION
TO
THE GENTILE RESIDENCE
8. Existing surfaces disturbed during the course of the Work shall be reconstructed and
finished to match adjoining surfaces. Patched areas shall be finished in such a manner
as to provide visual and structural continuity across the entire affected surface.
9. All voids created or surfaces disturbed resulting from cutting, removal or installation of
elements as part of the Work shall be filled and finished to match adjoining construction.
10. Except as provided in the Documents, no structural member or element shall be cut
Without Written approval of the Architect. The General Contractor shall coordinate all
cutting and shall advise the Architect of any potential conflicts With new or existing
structure.
11. Demolition work shall only be carried out once all temporary shoring and bracing is in
place. Removal of all temporary supports shall be completed only after new Work is secure
and complete.
12. All materials, equipment and Workmanship shall conform to the requirements of
authorities having jurisdiction of the Work.
13. All materials and equipment shall comply With the Occupational Safety and Health Act,
including all amendments.
14. All materials and equipment shall conform to the requirements of authorities having
jurisdiction regarding not using or installing asbestos or asbestos -containing materials.
15. All paint used on all products and assemblies shall conform to A.N.S.I. Z66.1,
Specifications for Paints and Coatings Accessible to Children to Minimize Dry Film Toxicity.
16. All Warranties, guarantees and service maintenance agreements shall commence on the
date of Substantial Completion of the Work or of the item being guaranteed, Whichever is
later, so that the Owner may receive full use of the item for the guarantee or Warranty
period.
17. GENERAL WORK TO BE PERFORMED AS PART OF THE GENERAL CONSTRUCTION:
A. Seal cracks and openings to make the exterior skin of the building tight to Water and
air entry.
B. Provide adequate blocking, bracing, noilers, fastenings and other supports to install
parts of the Work securely. Blocking, bracing, noilers, fastenings and other supports
shall be of a type not subject to deterioration or Weakening as the result of
environmental conditions or aging.
C. Perform cutting and patching for all trades. Patch holes Where ducts, conduit, pipes
and other products pass through or are being removed from existing construction.
D. Provide chases, furred spaces, trenches, covers, pits, foundations and other
construction required in conjunction With the Work. If such construction is not
shown on the Drawings, coordinate With Architect for sizes and placement.
E. Provide and coordinate access doors and panels as required for access to equipment
requiring adjustment, inspection, maintenance or other access and as required for access
to spaces not otherwise accessible, such as attics and crawl spaces.
F. Check Drawings and manufacturers' literature for requirements for bases, pads, and
other supporting structures. Provide such structures. Remove supporting structures
associated With removed equipment and patch remaining surfaces.
G. As part of one year Warranty specified in the General Conditions, repair cracks and
other damage Which occur as a result of settlement and shrinkage during the first year
after Substantial Completion,
18. All Work shall conform to the applicable sections of the Massachusetts State Building
Code, Ninth Edition. For residential projects, particular attention shall be paid to Chapter
36 - One & Two Family Dwellings, especially Table 3606.2.3 "Fastener Schedule for Structurc
Members".
ABBREVIATIONS
AB,
ANCHOR BOLT
JT
JOINT
AF,F.
ABOVE FINISH FLOOR
LAG
LAG BOLT
ACT
ACOUSTICAL TILE
LAM.
LAMINATE
ALUM
ALUMINUM
LAV.
LAVATORY
ANOD
ANODIZED
L
LENGTH
0
AT
MFR
MANUFACTURER
BSMT
BASEMENT
M.O,
MASONRY OPENING
BIT
BITUMINOUS
MAT,
MATERIAL
BLK
BLOCK
MAX
MAXIMUM
BLKG
BLOCKING
MECH.
MECHANICAL
BOTT
BOTTOM
MIN.
MINIMUM
B.O.W.
BOTTOM OF WALL
MTD,
MOUNTED
BM
BEAM
NO
NUMBER
BLDG
BUILDING
NOM.
NOMINAL
CPT
CARPET
N.I.C.
NOT IN CONTRACT
CSMT
CASEMENT
N.T.S.
NOT TO SCALE
CK
CAULK(ING)
Q.C.
ON CENTER
CLG
CEILING
OH
OVERHEAD
CLOS
CLOSET
OPNG.
OPENING
COL
COLUMN
PNT,
PAINT
CONC.
CONCRETE
PTO
PAINTED
CMU
CONCRETE MASONRY UNIT
PNL
PANEL
CONST.
CONSTRUCTION
PART.
PARTITION
CON T.
CONTINUOUS
PL
PLATE
CJ
CONTROL/CONSTR. JOINT
PLAS.
PLASTER
CTSK
COUNTERSUNK
P,LAM.
PLASTIC LAMINATE
DET.
DETAIL
PLBG.
PLUMBING
DIA
DIAMETER
PLYWD
PLYWOOD
DIM.
DIMENSION
P.T.
PRESSURE TREATED
DR
DOOR
0. T.
QUARRY TILE
DH
DOUBLEHUNG
REQ'D
REQUIRED
DRWR
DRAWER
REF.
REFIGERATOR
DWG(S)
DRAWING(S)
REV.
REVISIONS
DF
DRINKING FOUNTAIN
R
RISER
DW
DISHWASHER
RD
ROOF DRAIN
ELEC.
ELECTRIC(AL)
RM.
ROOM
EL
ELEVATION
R.O.
ROUGH OPENING
ELEV.
ELEVATOR
SECT.
SECTION
EMER
EMERGENCY
SCHED.
SCHEDULE
EQ
EQUAL
SPEC.
SPECIFICATIONS
EXIST.
EXISTING
SL
SIDELIGHT
or EXG.
STD.
STANDARD
EJ
EXPANSION JOINT
S&P
SHELF&POLE
EXP
EXPOSED
STL
STEEL
EXT.
EXTERIOR
SUSP.
SUSPENDED
FIN
FINISHED
THK
THICK
FA
FIRE ALARM
T&B
TOP&BOTTOM
F.B.O.
FURNISHED BY OWNER
T&G
TONGUE&GROOVE
FE
FIRE EXTINGUISHER
T.O.F.
TOP OF FOUNDATION
FL
FLOORING)
T.Q.W.
TOP OF WALL
FLUOR
FLUORESCENT
T
TREAD
FT
FOOT
TYP.
TYPICAL
FTG.
FOOTING
UNFIN,
UNFINISHED
FND.
FOUNDATION
V.I.F.
VERIFY IN FIELD
FURR
FURRED(ING)
VIN
VINYL
G
GAS
VCY
VINYL COMPOSITION TILE
GALV.
GC
GALVANIZED
GENERAL CONTRACTOR
VVWWC
VINYL WALL COVERING
GL
GLASS/GLAZING
WC
WATER CLOSET
GR
GRADING
W
WIDE/WIDTH
GYP.BD.
GYPSUM BOARD
w/
fly/0
WITH
WITHOUT
HDBD
HARDBOARD
W,W,M.
WELDED WIRE MESH
HDWD
HARDWOOD
WD
WOOD
HVAC
HEATING,VENTILATING,
& AIR CONDITIONING
HDWR
HARDWARE
HGT
HEIGHT
H.M.
HOLLOW METAL
INSUL
INSULATION
INT.
INTERIOR
JT
JOINT
LS
NORTH ARROW
SECTION INDICATOR - LETTER IN TOP
HALF OF CIRCLE INDICATES THE
SPECIFIC SECTION. THE NUMBER AND
LETTER IN THE BOTTOM HALF INDICATES
THE DWG. No.
NEW SPOT ELEVATION
EXISTING SPOT ELEVATION
LEVEL LINE OR WORKING POINT
ROOM NUMBER
DOOR NUMBER
WINDOW TYPE
WALL TYPE
REVISION MARK
CONCRETE - PLAN OR SECTION
BRICK - PLANS OR SECTIONS
CONCRETE BLOCK PLANS OR SEC.
PLYWOOD
STEEL, LARGE SCALE
ROUGH LUMBER
FINISH LUMBER
INSULATION - RIGID
INSULATION - BATT
EARTH
COMPACT GRAVEL
WELDED WIRE MESH
PROPERTY LINE
CENTER LINE
7% _1� 1;
REVIEWED F : 1,,"t-DING AND ZONING COD-- COi,4f'LI-
AN',-_ t n : �. OiviMISSIONS DO IV'OT R-LIEVE THE
AF'I THE RESPONSIBILI OF"AS BUILT"
C®lyi� 4ifilkL��� l ,
DATE: W -
t _
N
c
BIJILDiNG OFFICIAL
N
U
E
yO
i n
a
Q
Q
Lu
Q
ry
N
i
w
°Q
I—
rn
m=
o
°
`"
ry
Q
nn
SCHEDULE OF DRAWINGS
T-1 TITLE SHEET
A-1 FLOOR PLANS/
WINDOW & DOOR SCHEDULES
A-2 ELEVATIONS
A-3 FOUNDATION PLAN/
FIRST FLOOR FRAMING PLAN/
NAILING SCHEDULE
A-4 ROOF FRAMING PLAN
BUILDING SECTIONS
DRAWINGS ARE
REPRESENTATIONAL ONLY
DO NOT
SCALE
DRAWINGS
W
Z
U
0
z
1---
W
Q
0
>
U
0
W
1110
W
0
—
W
0
�
W
<
-T
TI TLE:
°
<C
W
W
..
�
Z
0
-:3::7
0
r
In
c 1
TITLE SHEET
DATE ISSUED:
09/14/2022
REVISIONS:
DRAWN BY:
PROJECT #:
DRAWING NO.:
T1
L