Loading...
HomeMy WebLinkAbouty I a,i/eii / /17)2� ONE & TWO FAMILY ONLY- BUILDING PERMIT Town of Yarmouth Building Department 1146 Route 28, South Yarmouth,MA 02664-4492 508-398-2231 ext. 1261 Fax 508-398-0836 Massachusetts State Building Code,780 CMR . w e Building Permit Application To Construct, Repair, Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only D Building Permit Number: -a,j - qq g Date Applied: 112022 1 r, Sears /a-/q-- OCT BuiLding Official(Print Name) Signature Date=lilt oING DEPARTMENT SECTION 1:SITE INFORMATION1.1 3�Property��dress: 1.2 Assessors Map&Parcel Numbers flCl y 1.1 a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required I Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone: — Outside Flood Zone? Municipal❑ On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP` 2.1 Owner'of Record: 61CtiY,e, MalCAYY1 Yarrnoi)-+-h MA 0a(913 Name(Print) City,State,ZIP .3 a ?dW Y) 13 OO1- QC( 774 368 378.E oa�4+rmnvr ,tsTJru Ln , r Y►-, No.and Street Telephone Emai[m Ad ss SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction 0 Existing Building❑ Owner-Occupied 0 I Repairs(s) 0 Alteration(s) 0 I Addition 0 Demolition ❑ I Accessory Bldg. 0 Number of Units Other 0 Specify: Brief Description of Proposed Work'-: 0 kaiipn p( pin -,A.V.0 e(-t-rd P1I 964 -r') 31 parloIS 11 ,906V-k) SECTION 4:ESTIMATED CONSTRUCTION COSTS • Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building 3 TOE. 0V I. Building Permit Fee:S /�Indicate how fee is determined: 2.ElectricaI $ o�; .d v . ❑Standard City/Town Application Fee Q Total Project Cost3(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ � U n 4.Mechanical (HVAC) $ List: aik AA 3 l�G' 1/11 5.Mechanical (Fire $ - • Suppression) Total All Fees:$ Check No. Check Amount: Cash Amount: 6.Total Project Cost: $ a'11/../-1 .d( 0 Paid in Full ❑Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction �Supervisor License(CSL) Q/ ' Q�' r f' � C e)si- hell License` Number O\ Expiration Date Name of CSL Holder �n List CSL Type(see below) U (ogFj my Le 5 Si .nCISi2 1314C� No.and Street Type Description -ra U n+on v' W o a,,Q U ( Unrestricted(Buildings up to 35,000 cu.ft.) City/Town,State,ZIP ' U` C�/1 lJ R Restricted 1u2 Family Dwelling M Masonry RC f Roofing Covering WS Window and Siding '�2��� SF Solid Fuel Bumino Appliances J 1 on I Insulation Telephone Email a e `(eyess D Demolition 5.2 Registered Home Improvement Contractor(HIC) Flo a,.\ 14311 I �/ 1 V-1�11LI pun run .►ns-iet11Oj 1(15Y ICP HIC Registration Number Expiration DateHIC Company i ame r C Registrant Name laQ 6 my L us 5i-nCis►2 elvd Pastn-ripp t+5(c sun n .cord No.and Street Email a8ress a TQ.lmtm mkoa-780 q"181/37381 i City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes No 0 SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize to act on my behalf,in all matters relative to work authorized by this building permit application. See C13(ft(&Ck _ Print Owner's Name(Electronic Signature) Date • SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my Iciowledge and understanding. Print of s or J.horized Agen'r's a onic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.nov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft,) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system 4'umber of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" .• *,,or SUNRINC-02 LWANG2 CORE) DATE(MM/DD/YYYY) CERTIFICATE OF LIABILITY INSURANCE 8/31/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER License#0C36861 CONTACT NAME: Walter Tanner Alliant Insurance Services,Inc. PHONE I FAX 560 Mission St 6th Fl (A/C,No,L Ext): (A/C,No): San Francisco,CA 94105 ADDRESS:Walter.Tanner@alliant.com INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:Evanston Insurance Company 35378 INSURED INSURER B:James River Insurance Company 12203 Sunrun Installation Services,Inc INSURER C:American Zurich Insurance Company 40142 775 Fiero Lane,Suite 200 Ph#805-540-7643 INSURERD: San Luis Obispo,CA 93401 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTR INSD_WVD (MM/DD/YYYY) 1MM/DD/YYYYI A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2,000,000 CLAIMS-MADE X I OCCUR MKLV5ENV103749 10/1/2022 10/1/2023 PREM SES(Eaoccu ence) $ 1,000,000 MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 X POLICY X JECT LOC PRODUCTS-COMP/OP AGG $ 2,000,000 _ X OTHER:Retention:$100,000 Per Project Agg $ 5,000,000 D AUTOMOBILE LIABILITY EDaaccciden SINGLE LIMIT ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOSO ONLY AUTOS BODILY BODILY INJURY(Per accident) $ AUTOS ONLY AUUTOS ONLYY PROPERTY DAMAGE (Per ccident) $ B UMBRELLA LIAB` X OCCUR EACH OCCURRENCE $ 4,000,000 X EXCESS LIAB CLAIMS-MADE 001072261 10/1/2021 10/1/2022 AGGREGATE $ 4,000,000 DED RETENTION$ $ C WORKERS COMPENSATION IX STATUTE ERH AND EMPLOYERS'LIABILITY 1,000,000 WC614287601 10/1/2022 10/1/2023 AAFFICEWMEMBER EXCLUDED?ECUTIVE N N/A E.L.EACH ACCIDENT $ (Mandatory In NH) i E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below _ E.L.DISEASE-POLICY LIMIT $ I , DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) Workers'Compensation Policy WC614287601 Deductible:$1,000,000. Re:Permitting within jurisdiction. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town of Yarmouth ACCORDANCE WITH THE POLICY PROVISIONS. 1146 Route 28 South Yarmouth,MA 02664-4492 - AUTHORIZED REPRESENTATIVE ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD Commonwealth of Massachusetts Construction Supervisor Orvrsion of Professional Licensure Unrestricted -Buildings of any use group which contain Board of Building Regulations and Standards less than 36,000 cubic feet(991 cubic milers)of enclosed C o its rlJCt�brl3ufYg P.i Si:r ' CS-Od0622 cyOlres_08/01/2023 STEPHEN A KELLY 16 PARKWAY-ROAD STONEHAM) 02110 / 1 >i • .rvr)413�1 C�Jr� Failure to possess a current edition of the Massachusetts Corn missioner ;y � Q4+1L�14L State Building Code is cause for revocation of this license. tJ For information about this license Call(917)727-3200 or visit wwwrnass.govldpi THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs and Business Regulation 1000 Washington Street-Suite 710 Boston,Massachusetts_02118 Home Improv_einent Registration • f _ Tye Supplement Card SUNRUN INSTALLATION SERVICES INC. Registration Registration 180120 21 WORLDS FAIR DR Expiration 10113I2024 SOMERSET,NJ 08873 - Update Address and Return Card THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Aire.&Business Regulation Registration valid for individual use only before the HOME IMPROVEMENT CONTRACTOR expiration dale.8 round return to: TYPE:Supplement Card Office of Consumer Affairs and Business Regulation fiegtetauen gaiwation 1000 Washing:on Street•Sudo 710 180120 10/13/2024 60610n,MA 01118 SUNRUN INSTALLATION SERVICES INC. STEPHEN KELLY n 2258USH STREET L54,,.t(il �GS SUITE 1400 SAN FRANCISCO,CA 94104 Undengadl/y t'valid without ry gesture Stephen A Kelly 695 Myles Standish Blvd Taunton MA 02780 TEL:978-793-7881 Email: eastmapermits@sunrun.com The Commonwealth of Massachusetts Department of Industrial Accidents —,:.,-_'=, Office of Investigations =_=�i= Lafayette City Center -4210,— 2 Avenue de Lafayette, Boston,MA 02111-1750 �..•`s www mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Sunrun Installation Services Address:225 Bush St STE 1400 City/State/Zip:San Francisco CA 94104 Phone#: Are you an employer?Check the appropriate box: Type of project(required): 1.® I am a employer with 50 4. 0 I am a general contractor and I 6. ❑ New construction employees(full and/or part-time).* have hired the sub-contractors 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have 8. ❑ Demolition workingfor me in anycapacity. employees and have workers' P h 9. 0 Building addition [No workers' comp. insurance comp. insurance.: required.] 5. 0 We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152, §1(4),and we have no employees. [No workers' 13.111 Other Olci( ;Z 5 comp. insurance required.] *My applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: American Zurich Insurance Company Policy#or Self-ins. Lic. #:WC614287601 Expiration Date: 10/01/2023 Job Site Address: 3 a -Tudor Zap(*) 24 City/State/Zip: Yc9 rrr1ol. , NA co 613 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury that the information provided above is true and correct. Signature: 47 Date: lh 1 610[a-- Phone#: Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License # Issuing Authority(check one): 10Board of Health 20 Building Department 3.LCity/Town Clerk 4.0 Electrical Inspector 5LIumbing Inspector 6.DOther Contact Person: Phone#: Information and Instructions Massachusetts General Laws chapter 152 requires all employers to provide workers' compensation for their employees. Pursuant to this statute, an employee is defined as"...every person in the service of another under any contract of hire, express or implied,oral or written." An employer is defined as"an individual,partnership,association,corporation or other legal entity,or any two or more of the foregoing engaged in a joint enterprise,and including the legal representatives of a deceased employer, or the receiver or trustee of an individual,partnership,association or other legal entity, employing employees. However the owner of a dwelling house having not more than three apartments and who resides therein,or the occupant of the dwelling house of another who employs persons to do maintenance, construction or repair work on such dwelling house or on the grounds or building appurtenant thereto shall not because of such employment be deemed to be an employer." MGL chapter 152,§25C(6)also states that"every state or local licensing agency shall withhold the issuance or renewal of a license or permit to operate a business or to construct buildings in the commonwealth for any applicant who has not produced acceptable evidence of compliance with the insurance coverage required." Additionally, MGL chapter 152, §25C(7)states"Neither the commonwealth nor any of its political subdivisions shall enter into any contract for the performance of public work until acceptable evidence of compliance with the insurance requirements of this chapter have been presented to the contracting authority." Applicants Please fill out the workers' compensation affidavit completely, by checking the boxes that apply to your situation and, if necessary, supply sub-contractor(s)name(s), address(es)and phone number(s)along with their certificate(s)of insurance. Limited Liability Companies(LLC)or Limited Liability Partnerships(LLP)with no employees other than the members or partners,are not required to carry workers' compensation insurance. If an LLC or LLP does have employees, a policy is required. Be advised that this affidavit may be submitted to the Department of Industrial Accidents for confirmation of insurance coverage. Also be sure to sign and date the affidavit. The affidavit should be returned to the city or town that the application for the permit or license is being requested, not the Department of Industrial Accidents. Should you have any questions regarding the law or if you are required to obtain a workers' compensation policy,please call the Department at the number listed below. Self-insured companies should enter their self-insurance license number on the appropriate line. City or Town Officials Please be sure that the affidavit is complete and printed legibly. The Department has provided a space at the bottom of the affidavit for you to fill out in the event the Office of Investigations has to contact you regarding the applicant. Please be sure to fill in the permit/license number which will be used as a reference number. In addition,an applicant that must submit multiple permit/license applications in any given year,need only submit one affidavit indicating current policy information (if necessary) and under"Job Site Address"the applicant should write"all locations in (city or town)."A copy of the affidavit that has been officially stamped or marked by the city or town may be provided to the applicant as proof that a valid affidavit is on file for future permits or licenses. A new affidavit must be filled out each year. Where a home owner or citizen is obtaining a license or permit not related to any business or commercial venture (i.e.a dog license or permit to burn leaves etc.)said person is NOT required to complete this affidavit. The Office of Investigations would like to thank you in advance for your cooperation and should you have any questions, please do not hesitate to give us a call. The Department's address,telephone and fax number: The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations Lafayette City Center, 2 Avenue de Lafayette Boston, MA 02111-1750 Tel. (617) 727-4900 or 1-877-MASSAFE Revised 7-2019 Fax (617) 727-7749 www.mass.gov/dia §TOWN OF YARMOUTH 1146 Route 28, South Yarmouth, MA 02664 508-398-22311 ext. 1261 Fax 508-398-0836 Office of the Building Commissioner BUILDING DEPARTMENT DEMOLITION DEBRIS DISPOSAL AFFIDAVIT Pursuant to M.G.L. Ch. 40, §54 and 780 CMR - Section 105.3.1. #4. I hereby certify that the debris resulting from the proposed work/demolition to be conducted at 31 low' h b Y JD1h Work Address Is to be disposed of oat the following location: (0C(cj 'Y?y 15 5- A5' Qj IC Yi-OY' mA °XiB O Said disposal site shall be a licensed solid waste facility as defined by M.G.L. Ch.;11-I, §150A. „Ady‘w to1ca)- Signature of Application Date Permit No. DocuSign Envelope ID:3589940E-AAE5-472C-9B55-AB378BE5390C Sunrun BrightSaveTM Agreement Elaine Malcolm 32 Town Brook Rd, Yarmouth, MA, 02673 Take Control of Your Electric Bill $0 25 Years $ 174 $0 .204 Deposit due Agreement Term Length Monthly Bill for Year Year 1 Cost per kWh Today (3.5% annual increase One (plus taxes, if applicable; (excluding upfront in monthly bill) includes $7.50 discount for payment, if any) Auto-Pay enrollment) WE'VE GOT YOU COVERED WITH OUR WORRY-FREE SERVICE —2? (7) 411 We provide hassle-free We monitor the system We warrant, insure. Selling your home? design, permitting, and to ensure it runs maintain and repair We guarantee the buyer installation. properly. the system. We will qualify to assume also provide a 10- your agreement. year roof warranty. A SOLAR SYSTEM DESIGN FOR YOUR HOME You get a 10.59 kW DC Solar System With 29 Solar Panels and 1 Inverter(s) Which will produce an est. 10,250 kWh in its first year And offset approx.98% of your current, estimated electricity usage YOUR SALES REPRESENTATIVE: Beshoy Mhareb beshoy.mhareb@sunrun.com (2 9) 507-2154 DocuSign Envelope ID:3589940E-AAE5-472C-9B55-AB378BE5390C By signing below, you acknowledge that you have reviewed and received a complete copy of the Agreement without any blanks. Such Agreement shall be the complete understanding between the Parties. SUNRUN I T' RPN SERVICES INC. Signatur 0°"w $' .. ,'`J B77CF1D18F3F485_. Print Name: Josi a Sandoval Date: 9/21/2022 Title: Sr. Contrart Rpvipw Rpprasentative Federal Employer Identification Number: 26-2841711 IF YOU CHOOSE TO PAY BY CHECK, MAKE CHECKS OUT TO SUNRUN INC. NEVER MAKE A CHECK OUT TO A SALES REPRESENTATIVE. OUR SALES REPRESENTATIVES ARE NOT AUTHORIZED TO RECEIVE CHECKS IN THEIR OWN NAMES. YOU MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF THE TENTH EFFECTIVE DATE. PLEASE REVIEW THE ATTACHED NOTICES OF CANCELLATION FOR AN EXPLANATION OF THIS RIGHT. Customer ,PrimejneMcount Holder Secondary Account Holder (Optional) EQa,i t, "VKae,aQaw \--53/Stpaittur-e-- Elaine Malcolm Signature 9/21/2022 Date Print Name Email Address*: bri 1 ai ne5@hotmai 1 .com Mailing Address: 32 Town Brook Rd Yarmouth, MA 02673 Phone: (774) 368-3786 `Email addresses will be used by Sunrun for official correspondence. such as sending monthly bills or other invoices. Sales Consultant By signing be/ow/acknow/edge that/am Sunrun accredited! that I presented this agreement according to oStiverix Code of Conduct, and that/obtained the homeowner's signature on this agreement. AgitimAtgc Beshoy Mhareb Print Name 1785775385 Sunrun ID number Sunrun Installation Services Inc. 1225 Bush Street, Suite 1400, San Francisco, CA 94104 1I 888.GO.SOLAR I HIC 180120 Contract Version: 2020Q1 V1 Generation Date: 9/21/2022 Proposal ID: PK49A1FKR69V-H Version 2020Q1 V1 21 =- EV projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.com 10/6/2022 RE: Structural Certification for Installation of Residential Solar ELAINE MALCOLM:32 TOWN BROOK RD,YARMOUTH, MA,02673 Attn:To Whom It May Concern This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report,the roof is made of Composite shingle roofing over roof plywood supported by 2X6 Rafters at 16 inches.The slope of the roof was approximated to be 25 degrees. After review of the field observation data and based on our structural capacity calculation, the existing roof framing has been determined to be adequate to support the imposed loads without structural upgrades. Contractor shall verify that existing framing is consistent with the described above before install.Should they find any discrepancies,a written approval from SEOR is mandatory before proceeding with install. Capacity calculations were done in accordance with applicable building codes. Design Criteria Code 2015 IRC(ASCE 7-10)-CMR 780 9th Ed Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 140 mph PV Dead Load DPV 3 psf Exposure C Roof Live Load Lr 20 psf Ground Snow S 30 psf If you have any questions on the above, please do not hesitate to call. STRUCT ;. ONL Sincerely, yAvA�jNCFM4S o S' VINCENT �s Vincent Mwumvaneza, P.E. 0 MWUMVANEZA EV Engineering, LLC N,Clvll 2 � proiects@evengineersnet.comERFo\4,�e http://www.evengineersnet.com '• oNAIENG 1/1 MEM EV projects@evengineersnet.com 276-220-0064 mum ENGINEERS http://www.evengineersnet.com Structural Letter for PV Installation 10/6/2022 Job Address: 32 TOWN BROOK RD YARMOUTH, MA, 02673 Job Name: ELAINE MALCOLM Job Number: 221006 EM Scope of Work This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing.All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Table of Content Sheet 1 Cover 2 Attachment checks 3 Snow and Roof Framing Check 4 Seismic Check and Scope of work Engineering Calculations Summary Code 2015 IRC(ASCE 7-10)-CMR 780 9th Ed Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 30 psf Wind Load (component and Cladding) V 140 mph Exposure C References NDS for Wood Construction STRUCT oNL 4�cy.NH Of M4SS9c Sincerely, � VINCENT N%, MWUMVANEZA N CIVIL Vincent Mwumvaneza, P.E. A N,�� o EV Engineering, LLC 4•,../•/: ERF \‘,k. proiects@evengineersnet.com �'� ONAIEN�' http://www.evengineersnet.com 1/1 • =- EV projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.com Wind Load Cont. Risk Category= II ASCE 7-10 Table 1.5-1 Wind Speed (3s gust),V= 140 mph ASCE 7-10 Figure 26.5-1A Roughness= C ASCE 7-10 Sec 26.7.2 Exposure= C ASCE 7-10 Sec 26.7.3 Topographic Factor, KZT= 1.00 ASCE 7-10 Sec 26.8.2 Pitch= 25.0 Degrees Adjustment Factor,A= 1.35 ASCE 7-10 Figure 30.5-1 a= 3.80 ft ASCE 7-10 Figure 30.5-1 Where a: 10%of least horizontal dimension or 0.4h,whichever is smaller,but not less than 4%of least horizontal dimension or 3ft(0.9m) Uplift(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= -29.3 -41.3 -65.1 Figure 30.5-1 Pnet=0.6 x t x KZT x Pnet30)= 23.75 33.46 52.75 Equation 30.5-1 Downpressure(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= 15.7 15.7 15.7 Figure 30.5-1 Pnet=0.6 x]t x KZT x Pnet30)= 12.73 12.73 12.73 Equation 30.5-1 Rafter Attachments:0.6D+0.6W(CD=1.6) Connection Check Attachement max.spacing= 5.3 ft 205 Ibs/in Lag Screw Penetration 2.5 in Allowable Capacity= 512.5 0.6D+0.6W Dpv+0.6W Zone Trib Width Area(ft) Uplift(Ibs) Down(Ibs) 1 5.3 11.4 250.1 179.2 2 5.3 11.4 360.7 179.2 3 3 6.5 328.6 101.4 Max= 360.7 < 512.5 CONNECTION IS OK 1. Pv seismic dead weight is negligible to result in significant seismic uplift,therefore the wind uplift governs 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. 1/1 millow V' EV projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.com Vertical Load Resisting System Design Roof Framing Pg= 30 psf ASCE 7-10,Section 7.2 pf= 21 psf Ce= 0.9 ASCE 7-10,Table 7-2 pfmin.= 25.0 psf Ct= 1.1 ASCE 7-10,Table 7-3 ps= 25 psf 25.0 plf IS = 1.0 ASCE 7-10,Table 1.5-1 CS 0.75 Max Length, L= 11.75 ft Tributary Width,WT= 16 in Dr= 10 psf 13.33 plf PvDL= 3 psf 4 plf Load Case: DL+0.6W Pnet+PpVcos(6)+Pot= 34.3 plf Max Moment, M„= 432 lb-ft Conservatively Pv max Shear 179.2 lbs Max Shear,V„=wL/2+Pv Point Load = 281 lbs Load Case: DL+0.75(0.6W+S)) 0.75(Pnet+Ps)+ PP cos(6)+PDT= 48 plf Mdown= 610 lb-ft Mallowable=Sx x Fb' (wind)= 1319 lb-ft > 610 lb-ft OK Load Case: DL+S Ps+PPVcos(0)+PDT= 42 plf Mdown= 529 lb-ft Mallowable=Sx x Fb' (wind)= 948 lb-ft > 529 lb-ft OK Max Shear,V„=wL/2+Pv Point Load = 285 lbs Member Capacity SPF#1/#2 2X6 Design Value CL CF C; Cr Adjusted Value Fb= 875 psi 1.0 1.3 1.0 1.15 1308 psi F„= 135 psi N/A N/A 1.0 N/A 135 psi E= 1400000 psi N/A N/A 1.0 N/A 1400000 psi Depth, d = 5.5 in Width, b = 1.5 in Cross-Sectonal Area,A= 8.25 in2 Moment of Inertia, Ixx= 20.7969 in4 Section Modulus,Sxx= 7.5625 in3 Allowable Moment, Mau= Fb'Sxx= 824.4 lb-ft DCR=M„/Mail= 0.53 < 1 Satisfactory Allowable Shear,Vaii=2/3F„'A= 742.5 lb DCR=V„/Vail= 0.19 < 1 Satisfactory 1/1 projects@evengineersnet.com 276-220-0064 limm ENGINEERS http://www.evengineersnet.com Siesmic Loads Check Roof Dead Load 10 psf %or Roof with Pv 30% Dpv and Racking 3 psf Averarage Total Dead Load 10.9 psf Increase in Dead Load 3.6% OK The increase in seismic Dead weight as a result of the solar system is less than 10%of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on information in pictures and a drawing set titled PV plans- ELAINE MALCOLM.The analysis was according to applicable building codes, professional engineering and design experience,opinions and judgments.The calculations produced for this structure's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. 1/1 SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS •SYSTEM SIZE:11005W DC,7600W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), 1011 SOLAR MODULES PAGE# DESCRIPTION •MODULES:(31)LONGI GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SERVICE ENTRANCE PV-1.0 COVER SHEET LTD:LR4-60HPB-355M INSTRUCTIONS. L ( a" PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. SE7600H-USSN MP MAIN PANEL I PV-3.0 LAYOUT •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV 4.0 ELECTRICAL SEE DETAIL SNR-DC-00436 •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SUB-PANEL SNR MOUNT 0 PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. SNR MOUNT 8 SKIRT •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER ;:T7;j CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER _ FLUSH ATTIC VENT MODULES,ARE CLASS A FIRE RATED. ., PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) ® METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC AC DISCONNECT(S) n SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC DC DISCONNECT(S) FIRE SETBACKS •11.25 AMPS MODULE SHORT CIRCUIT CURRENT. •17.57 AMPS DERATED SHORT CIRCUIT CURRENT(690.8(A)8 690.8(B)]. IQ COMBINER BOX _i HARDSCAPE CB •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). "r. CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INTERIOR EQUIPMENT —PL— PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L J SHOWN AS DASHED SCALE:NTS PERE AC ALTERNATING CURRENT s u n r u n AFC! ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION DC DIRECT CURRENT #180120 N yr Yarmouth (E) EXISTING 885 MYLES STANDISH BLVD,TAUNTON,MA,027807331 ESS ENERGY STORAGE SYSTEM PHONE 0FARO amstable EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC ELAINE MALCOLM --d ' � MSP MAIN SERVICE PANEL 32 TOWN BROOK RD, (N) NEW YARMOUTH,MA,02673 NTS NOT TO SCALE ux '� • OC ON CENTER TEL.(774)368-3786 PRE-FAB PRE-FABRICATED APN:YARM-000037-000086 e�souTH PSF POUNDS PER SQUARE FOOT •32 Town Brook Rd, f rARM0 ! PV PHOTOVOLTAIC PROJECT NUMBER: ID. West Yarmouth,MA... 4 RSD RAPID SHUTDOWN DEVICE 223R-032MALC : 0 7E dddd°°°. TL TRANSFORMERLESS DESIGNER: (415)580-6920 ex3 HYAkkIS wEST TYP TYPICAL ' W w WES1'rM V VOLTS MOHD TARIK W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET s^ - REV:A 10/6/2022 PAGE PV-1.0 ARRAY TRUE MAG PV AREA SITE PLAN DETAIL-SCALE=1I8"=1'-0" SITE PLAN -SCALE=1/32"=1'-0" PITCH AZIM AZIM (SOFT) f AR-01 25° 316° 332° 235.3 INI I k I AR-02 25° 138° 152° 372.6 #4#1 I I4 IIN0:1V0 I 1 ## \' ?O DE HE O 'c'• _-ai _..(E)GATE so* --(E)RESIDENCE (N)ARRAY AR-01 --- ` �` ..'' \\ �,�` STRUCTURED j--(N)ARRAY AR-02 g ;;,,,;,, (E)FENCE-- ,# a. ######## / ir, (E)DETACHED STRUCTURE AMP AC SnnE sunrun .13ii, INV --'/ 4#PM #180120 698 MYLES STANDISH BLVD,TAUN7ON,MA,02780 719L PHONE FAX 0 CUSTOMER RESIDENCE: ELAINE MALCOLM 32 TOWN BROOK RD, YARMOUTH,MA,02673 TEL.(774)368-3786 APN:YARM-000037-000086 PROJECT NUMBER: 223R-032MALC DESIGNER: (415)580-6920 ex3 MOHD TARIK SHEET SITE PLAN REV.A 10/6/2022 . PAGE PV-2.0 y d ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height T Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF g Type Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 2-Story 2X6 RAFTERS 11'-7" 16" COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREWS: AR-02 COMP SHINGLE-RLU 2-Story 2X6 RAFTERS 11'-9" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON 5'-4TM 2'-1" 4'-0" 2'-0" STAGGERED 5/16" 2.5"MIN EMBEDMENT COMP,SEE DETAIL SNR-DC-00436 STRUCTURAL NOTES: • INSTALLERS SHALL NOTIFY D1-AR-01-SCALE:1/8"=1'-0" ENGINEER OF ANY POTENTIAL AZIM:318° STRUCTURAL ISSUES PITCH:25° OBSERVED PRIOR TO PROCEEDING W/ } _ INSTALLATION. I I • IF ARRAY(EXCLUDING SKIRT) # 19 1 a IS WITHIN 12"BOUNDARY r 1;-6„ 0 0 ❑ ❑ ❑ ❑ REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS), 5 4"TYP f THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" 10'-4" BOUNDARY REGION ONLY AS ❑ 0 0 0 0 0 FOLLOWS: ••ALLOWABLE ATTACHMENT n n n n n SPACING INDICATED ON PLANS TO BE REDUCED BY 1;_2;, 50% ••ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS D2-AR-02-SCALE:1/8"=1'-0" AZIM:138° s u n ru n PITCH:25° 6" 40,_8„.. T 1,-0„ , #180120 r r --- <r-- , --- ❑ ❑ ❑ ❑ 0 ❑ 695 MYLES STANDISH BLVD,TAUNTON,Mk 627130,331 PHONE 0 FARO CUSTOMER RESIDENCE: 1C7-4„ ELAINE MALCOLM 32 TOWN BROOK RD, ❑ ❑ I ❑ 0 0 0 0 YARMOUTH,MA,02673 - 5.-4"TYP- 3,15„ I STRUCT .�..____.I n ►i n ,, n n n n r..... * ONL TEL.(774)368-3786 ��,,,,1N OF%is., APN:YARM-000037-000086 1,_2„ Fo CyG a VINCENT R, PROJECT NUMBER: }.1.-3„ o MWUMVANEZA N 223R-032MALC k_.... ._.__..1T_5„ 6'_4" 17,_5„ _._.. ... " CIVIL i� 2 415 580-6920 ex3 41'1" _.....__...._..._.__._._....__.._ _._._._.._......_ DESIGNER: ( ) •� o\�`' MOHD TARIK ONAIEN SHEET LAYOUT REV:A 10/6/2022 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE O METER#: NOTE:TOTAL PV BACKFEED=40A EVERSOURCE 2205863 USED FOR INTERCONNECTION UTILITY CALCULATIONS 46 GRID 1 - L,-SUPPLY SIDE TAP (N)LOCKABLE I EXISTING 100A BLADE TYPE (N)MA SMART MAIN BREAKER FUSED AC UTILITY SOLAREDGE TECHNOLOGIES: 1 DISCONNECT METERVUE SE7600H-USSN 7600 WATT INVERTER JUNCTION BOX PV MODULES 3 (3) - (2l OR EQUIVALENT ('.1') LONGI GREEN ENERGY TECHNOLOGY EXISTING \' // CO LTD:LR4�OHP8-355M 100A MAIN U r _ .-�� j I � +�j/ (31)MODULES �� PANEL `� U M I 1' `Y OPTIMIZERS WIRED IN: FACILITY 40A FUSES I 4 I to SERIES OF(16)OPTIMIZERS LOADS 4= SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT (1)SERIES OF(15)OPTIMIZERS D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN L SOLAREDGE POWER OPTIMIZERS 3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT P401 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 685 MYIES STANDI...3 TAUNTON.MA,027804331 PHONE 0 1 CUSTOMER RESIDENCE: ELAINE MALCOLM 32 TOWN BROOK RD, YARMOUTH,MA,02673 MODULE CHARACTERISTICS P401 OPTIMIZER CHARACTERISTICS: TEL.(774)368-3786 LONGI GREEN ENERGY MIN INPUT VOLTAGE: 8 VDC APN:YARM-000037-000086 TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: LR4-60HPB-355M: 355 W MAX INPUT ISC: 11.75 ADC 223R-032MALC OPEN CIRCUIT VOLTAGE: 40.6 V MAX OUTPUT CURRENT: 15 ADC MAX POWER VOLTAGE 34.6 V DESIGNER: (415)580-6920 ex3 SHORT CIRCUIT CURRENT: 11.25 A MOHD TARIK SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM SIZE: 11005 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 16 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE 480 V REV.A 10/6I2022 SYSTEM OPERATING CURRENT: 27.51 A SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0 • I J /WARNING INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE: 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS. •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(B) WARNING:PHOTOVOLTAIC AWARNING POWER SOURCE LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. —- AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(D)(2),IFC 2012: SYSTEM 605.11.1.4 LABEL LOCATION: CAUTION : UTILITY SERVICE METER AND MAIN I SERVICE PANEL. PER CODE(S):NEC 2020:705.12(C) -- /\WARNIN •G RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM SOLAR PANELS ON ROOF DO NOT RELOCATE THIS 1 , OVERCURRENT DEVICE LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN ' LABEL LOCATION: SWITCH PER CODE(S):NEC 2020:690.56(C)(2),IFC s u n r u n ADJACENT TO PV BREAKER AND ESS 2012'605 11 1,iFr 2018:1204.5.3 rill; OCPD(IF APPLICABLE). PER CODE(S):NEC 2020: 705.12(B)(3)(2) #180120 www /WARNING SOLAR PV SYSTEM EQUIPPEDPHOTOVOLTAIC SYSTEM B95 MYlES SiMgISH BLVD.TAUNLON,MA.d1]B6)3]tCOMBINER PANEL WITH RAPID SHUTDOWN Fes° DO NOT ADD LOADS CUSTOMER RESIDENCE: ELAINE MALCOLM LABEL LOCATION: PHOTOVOLTAIC AC COMBINER OF 32 TOWN BROOK RD, APPLICABLE). PER CODE(S):NEC 2020:705.72(D)(2)(3)(c) TURN RAPID SHUTDOWN MAIN PANEL (I NT)-- YARMOUTH,MA,02673 SWITCH TO THE"OFF" —INVERTER (EXT) TEL.(774)368-3786 POSITION TO SHUT DOWN `°� SERVICE ENTRANCE API:YARM-000037-000086 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE —PRODUCTION METER PROJECT NUMBER: MAXIMUM AC OPERA I ING CURRENT.31.67 AMPS SHOCK HAZARD IN THE FUSED AC— 223R-032MALC NOMINAL OPERATING AC VOLTAGE: 240 VAC ARRAY. MI DISCONNECT DESIGNER: (415)580-6920 ex3 - • LABEL LOCATION: 32 TOWN BROOK RD, YARMOUTH, MA, 02673 MOHDTARIK AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. SHEET PER CODE(S):NEC 2020:690.54 LABEL OR NO MORE THAT)M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2020:705.10,710.10 SIGNAGE ON DISCONNECTING MEANS TO WHICH THE PV SYSTEMS • ARE CONNECTED. REV:A 10/6/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0