Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
bld-23-001313
41/13)32, ----_- RECEe ' Eta , ONE & TWO FAMILY ONLY- BUILDING PERMIT S P 0 9 2022 j Town of Yarmouth Building Department Kirk 1146 Route 28,South Yarmouth,MA 02664-4492 L'•;.+ �., k EPdRTMENI 508-398-2231 ext. 1261 Fax 508-398-0836 <,_,.��.1. C Massachusetts State Building Code,780 CMR ` " Building Permit Application To Construct, Repair, Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: 6 L b-2 3 -bn 1 13 Date Applied: 'TM (R.Pic S _...7-17::: 9 f 3- Building Official(Print Name) ignature Date SECTION 1:SITE INFORMATION I. Property Address: I.2 Assessors Map&Parcel Numbers UC (I Yarmck RC\ Li a Is this an accepted street?yes ✓ no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required ' Provided Required t Provided i 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone: — Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' [yam 2.1.Q Her'of in Record: ' C U\ 1Qr A MIN O&C1 Name (Prin City,State,ZIP ea LI Yotrmcukb ReI TN:R io-Ma No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction❑ Existing Building 0 Owner-Occupied 0 I Repairs(s) 0 Alteration(s) 0 I Addition 0 Demolition 0 Accessory Bldg. 0 Number of Units 1 Other lYSpecify: ,Solo r Da�S Brie Description f Proposed Work': Task Jlrj//C�n Of root Mnfi'/cd hDki 1c uot 6 Spar aistrns, SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building $ L 1 1 11. Building Permit Fee:$�5-() Indicate how fee is determined: Q Q 0 Standard City/Town Application Fee 2.Electrical $ n`1 ,Q u U .03 0 Total Project Cost3(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 0,0 AA 3 OD otal d- 5.Mechanical (Fire $ . _ " Suppression) Total All Fees:$ $ Check No. Check Amount: Cash Amount: 6.Total Project Cost: —a y 0 Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 ICoonstrr�uction,(Supervisor License(CSL) ('1t� �(j(, 9n 2-'_g3 NU`, �" e.q License Number Expiration Date Name of CSL Holder J cqn M es l/�rd ish j�l)I List CSL Type(see below) L) No.and Street 1y �J l Type Description lounpn t I t U Unrestricted(Buildings up to 35,000 cu.it)1 1OO R Restricted l&2 Family Dwelling City/Town,State,ZIP M Maso RC I Roofing Covering WS Window and Siding �n SF Solid Fuel Burning Appliances g1g-7g3-71%I enstrcc' rri t-se, urlrun4L( I Insulation Telephone Email address D Demolition 5.2 Registered Home Imp oval Bern Contractor(HIC) /d011[V /V-13.2 Sor\rurr Thgo ilal(01 lTuiCe3 HIC Registtrrattioon Number Exxpiration DateHr�C�parry}�IamL�i C��sr��I.S�e 1�y p��j y�.� andst�eetM� MA ^�Q l��l„ Vrni}S(�srUn,C(�`— COI-- No—and t I 1 t'1 t(� 1 A( q7 2.19 3 .7 ill Email address City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.1.52.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes E' No 0 SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMITI,as Owner of the subject property,hereby authorize S � It /Sunrun to act on my behalf,in all matters relative to work authorized by this built it permit application. 1 5et GVkcikd\ corirod q -2-W)Dft) Print Owner's Name(Electronic Signature) Date • SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this a lication is true and accurate to the best of my knowledge and understanding. e q-2-Daga Print Owner's or Au' .tzed Agent's Name(Electr c Signature) Date NOTES: I. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.eov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches i Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" 7 ____—.—....4p SUNRINC-02 TWANG ,44CoR0 CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) 44.-----" 9/10/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Walter Tanner NAME: Alliant Insurance Services,Inc. PHONE FAX 575 Market St Ste 3600 (A/c No,Ext): (A/C,No): E-MAIL Walter.Tanner@alliant.com San Francisco,CA 94105 ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:Navigators Specialty Insurance Company 36056 INSURED INSURERB:James River Insurance Company 12203 -_ Sunrun Installation Services,Inc INSURER C:American Zurich Insurance Company 40142 775 Fiero Lane,Suite 200 Ph#805-540-7643 INSURERD: San Luis Obispo,CA 93401 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUER POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTR INSD WVD (MM/DD/YYYY) IMM/DD/YYYY) A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $-- 2,000,000 CLAIMS-MADE X OCCUR LA21 CGL230321IC 10/1/2021 10/1/2022 DAMAGE TO RENTED PREMISES PREMISES(Ea occurrence) $ MED EXP(Any one person $ 5,000 PERSONAL&ADV INJURY $ _- 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 X_ POLICY X PRO-JECT ' LOC PRODUCTS-COMP/OP AGG $ _ 2,000 000 X OTHER:Retention:$100,000 Per Project Agg $ 10,000,000 COMBINED SINGLE LIMIT AUTOMOBILE LIABILITY (Ea_amidg4t)__. ___$_ ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ HIRED AOOWNNY PROPERTY DAMAGEAUTS ONLY AUTOS ONLY [Per accident - $ __. B UMBRELLA LIAR X OCCUR EACH OCCURRENCE $ 4,000,000 X EXCESS LAB CLAIMS-MADE 001072261 10/1/2021 10/1/2022 AGGREGATE $ 4,000,000 DED RETENTION$ $ C WORKERS COMPENSATION X PER OTH- AND EMPLOYERS'LIABILITY STATUTE -__ER YIN WC614287600 10/1/2021 10/1/2022 1,000,000 ANY PROPRIETOR/PARTNER/EXECUTIVE N N/A E.L.EACH ACCIDENT $ _ OFFICER/MEMBER EXCLUDED? -- --_- - (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 1'000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space is required) Workers'Compensation Policy WC614287600 Deductible:$1,000,000. Re:Permitting within jurisdiction. CERTIFICATE HOLDER CANCELLATION - SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town of Yarmouth ACCORDANCE WITH THE POLICY PROVISIONS. 1146 Route 28 South Yarmouth,MA 02664-4492 — AUTHORIZED REPRESENTATIVE 2 / ' ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD - - 1 The Commonwealth of Massachusetts Department of Industrial Accidents 1_ , Office of Investigations Lafayette City Center —4- 2 Avenue de Lafayette, Boston,MA 02111-1750 www.mass.gov/dia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Sunrun Installation Services Address:225 Bush St STE 1400 City/State/Zip:San Francisco CA 94104 Phone#: 978-793-7881 Are you an employer?Check the appropriate box: Type of project(required): 1.® i am a employer with 50 4. ❑ I am a general contractor and l 6. New construction employees(full and/or part-time).* have hired the sub-contractors 2.❑ i am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g. ❑ Demolition working for me in any capacity. employees and have workers' 9. ❑ Building addition [No workers' comp. insurance comp. insurance. t required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGI. 12.❑ Roof repairs insurance required.] + c. 152, §1(4),and we have no employees. [No workers' 13.12 Other Roof Mounted Solar comp. insurance required.] `Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information +Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees If the sub-contractors have employees,they must provide their workers'comp.policy number t am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. insurance Company Name: American Zurich Insurance Company Policy#or Self-ins. Lic.#:WC614287600 Expiration Date: 10/01/2022 Job Site Address:CMG W `V.1r mpO tlt City/State/Zip:" C \eJj'tlf\ , ! I\ . ()QC T J Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury that the information provided above is true and correct. in Signature: u -_-_ Date: CI- !) . _Qbgi -- Phone 4: 978-79 -7881 — Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License # Issuing Authority(check one): i❑Board of Health 2❑Building Department 3❑City/Town Clerk 4.0 Electrical inspector 50Plumbing Inspector 6.0Other Contact Person: Phone#: Commonwealth of etas sac nusetts ConstrtaCtirxl SupervisorDry lion of Professional Ucensure UtwestsLted -Buildings of any use group which contain Board of Building Regulations and Standards less than 36,000 cubic feet 1991 cubic milers)of enclosed C O ns(71JCf(Oh"Stiperyis°, fie' CS-040622 r apires.08101 2023 STEPHEN A FELLY 16 PARKWAY ROAD STONEHAM CO 021116 ef 4141.:�ntia� A Falffre to possess a current edition of the Massachusetts Commissioner � Fi{„t ta_ I State Budding Code is cause for revocation of this license. For information about this license Call(617)727.1200 or visit werwlnass.gOvldpi Office of Consumer Affairs and Business Regulation 1000 Washington Street-Suite 710 Boston,Massachusetts 021 18 Home Improvement Contractor Registration Type: Supplement Card Registration. 180120 SUNRUN INSTALLATION SERVICES INC Euxratan: 10/13,2022 225 BUSH STREET SUITE 1400 SAN FRANCISCO,CA ge 104 Update Address and Return Card (mice Or L0001IO, &9UeaIMe Regulation HOME IMPROVEMENT CONTRACTOR Registration valid for individual use only TYPE. rue--e-: ar s before the eapeation date If found return to $esalpyigp Emi a= Office of Consumer Affairs and Business Regulation 180120 'S 11^_022 1000 Washington Street-Suite 710 SUNRUN INSTALLATION SERVICES INC Boston MA 02118 STEPHEN KELLY 225 BUSH STREET —�— SUITE 1400 Not id without sign unit SAN FRANCISCO CA ge10e 'Underse`'-etary Stephen A Kelly 734 Forest ST STE 400 Marlborough MA 01752 TEL: 978-793-7881 Email: mapermits@sunrun.com L/,L 7 o"f E TOWN OF YARMOUTH '� BUILDING DEPARTMENT � 60•`p TT,re kat 1 146 Route 28,South Yarmouth,MA 02664 508-398-2231 ext. 1261 HOMEOWNER LICENSE EXEMPTION PLEASE PRINT: DATE: q- 2 -laa JOB LOCATION: COG U \thmocA W NAME STET ADDRESS SECTION OF TOWN "HOMEOWNER" TncQufs 3 Ip u 17y - 26 Ilca NMvIE HOME PHONE WORK PHONE PRESENT MAILING ADDRESS CITY OR TOWN STATE ZIP CODE The current exemption for `Homeowner' was extended to include owner—occupied dwellinas of one or two units and to allow such homeowners to engage an individual for hire who does not possess a license,provided that such homeowner shall act as supervisor. (State Building Code Section 110 R5.1.3.1) Definition of Homeowner: Person(s)who owns a parcel of land on which he/she resides or intends to reside,on which there is or is intended to be, a one or two family attached or detached structure assessory to such use and/or farm structures. A person who constructs more than one home in a two-year period shall not be considered a homeowner;such"homeowner"shall submit to the building official,on a form acceptable to the building official,that he/she shall be responsible for all such work performed under the building.permit. (Section 110 R5.1.3.1) The undersigned `homeowner' assumes responsibility for compliance with the State Building Code and other applicable codes,by-laws, rules and regulations. The undersigned 'homeowner' certifies that he/ she understands the Town of Yarmouth Building Department minimum inspection procedures and requirements and that he / she will comply with said procedures and requirements. HOMEOWNER"S SIGNATURE APPROVAL OF BUILDING OFFICIAL INSURANCE COVERAGE: I have a current liability insurance policy or its substantial equivalent, which meets the requirements of MGL Ch.142. Yes No If you have checked ves,please indicate the type coverage by checking the appropriate box. A liability insurance policy Other type of indemnity Bond OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 142 of the Mass. General Laws and that my signature on this permit application waives this requirement. Check one: Signature of Owner or Owner's Agent Owner Agent h:homeownrlicexemp §TOWN OF YARMOUTH 1146 Route 28, South Yarmouth, MA 02664 508-398-22* ext. 1261 Fax 508-398-0836 Office of the Building Commissioner BUILDING DEPARTMENT DEMOLITION DEBRIS DISPOSAL AFFIDAVIT Pursuant to M.G.L. Ch. 40, §54 and 780 CMR- Section 105.3.1. #4. I hereby certify that the debris resulting from the proposed work/demolition to be conducted at Cam, L\ `(0rrnck41� Work Address Is to be disposed of oat the following location:C T) M S�O�r ISM �` 7CSJ IN y Said disposal site shall be a licensed solid waste facility as defined by M.G.L. Ch. 111, §150A. Signature f Application Date Permit No. t , =- EV projects@evengineersnet.com 276-220-0064 amok ENGINEERS http://www.evengineersnet.com 9/8/2022 RE:Structural Certification for Installation of Residential Solar JACQUES J PAUL:606 W YARMOUTH RD,YARMOUTH, MA,02673 Attn:To Whom It May Concern This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report,the roof is made of Composite shingle roofing over roof plywood supported by 2X6 Rafters at 20 inches.The slope of the roof was approximated to be 40 and 6 degrees. After review of the field observation data and based on our structural capacity calculation, the existing roof framing has been determined to be adequate to support the imposed loads without structural upgrades. Contractor shall verify that existing framing is consistent with the described above before install. Should they find any discrepancies, a written approval from SEOR is mandatory before proceeding with install. Capacity calculations were done in accordance with applicable building codes. Design Criteria Code 2015 IRC(ASCE 7-10)-CMR 780 9th Ed Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 140 mph PV Dead Load DPV 3 psf Exposure C Roof Live Load Lr 20 psf Ground Snow S 30 psf If you have any questions on the above, please do not hesitate to call. STRUCT ONL Sincerely, ���SH OF,M4ss9c � VINCENT G mot, Vincent Mwumvaneza, P.E. o MWUMVANEZA N EV Engineering, LLC N ICIVIL. 2 projects@evengineersnet.com \\., http://www.evengineersnet.com • ,ONALENG 1/1 - EV projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.com Structural Letter for PV Installation 9/8/2022 Job Address: 606 W YARMOUTH RD YARMOUTH, MA,02673 Job Name: JACQUES J PAUL Job Number: 220908 BP Scope of Work This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing.All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Table of Content Sheet 1 Cover 2 Attachment checks 3 Snow and Roof Framing Check 4 Seismic Check and Scope of work Engineering Calculations Summary Code 2015 IRC(ASCE 7-10)-CMR 780 9th Ed Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 30 psf Wind Load (component and Cladding) V 140 mph Exposure C References NDS for Wood Construction STRUCT ;. oNL 4�7,0SH Of MMS,s, O ti Sincerely, VINCENT s� O MWUMVANEZA CIVIL Vincent Mwumvaneza, P.E. INS% 2 EV Engineering, LLC j';'�►%: PIO�,s``� projects even gineersnet.com �� �NAIENG\ http://www.evengineersnet.com 1/1 - Ey projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.com Wind Load Cont. Risk Category= II ASCE 7-10 Table 1.5-1 Wind Speed (3s gust),V= 140 mph ASCE 7-10 Figure 26.5-1A Roughness= C ASCE 7-10 Sec 26.7.2 Exposure= C ASCE 7-10 Sec 26.7.3 Topographic Factor, Kn= 1.00 ASCE 7-10 Sec 26.8.2 Pitch = 40.0 Degrees Adjustment Factor,A= 1.21 ASCE 7-10 Figure 30.5-1 a = 2.70 ft ASCE 7-10 Figure 30.5-1 Where a: 10%of least horizontal dimension or 0.4h,whichever is smaller,but not less than 4%of least horizontal dimension or 3ft(0.9m) Uplift(0.6W1 Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= -29.3 -35.3 -35.3 Figure 30.5-1 Pnet=0.6 x it x KZT x Pnet30)= 21.29 25.64 25.64 Equation 30.5-1 Downpressure(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= 32.1 32.1 32.1 Figure 30.5-1 Pnet=0.6 x A x KZT x Pnet30)= 23.28 23.28 23.28 Equation 30.5-1 Rafter Attachments:0.6D+0.6W(CD=1.6) Connection Check Attachement max.spacing= 5 ft 5116"Lag stre Wi r `wail clue= 205 lbs/in Lag Screw Penetration 2.5 in Allowable Capacity= 512.5 0.6D+0.6W Dpv+0.6W Zone Trib Width Area(ft) Uplift(Ibs) Down(Ibs) 1 5 10.8 209.5 282.6 2 5 10.8 256.2 282.6 3 3 5.8 138.4 152.6 Max= 256.2 < 512.5 CONNECTION IS OK 1. Pv seismic dead weight is negligible to result in significant seismic uplift,therefore the wind uplift governs 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. 1/1 • mm1- EV projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.com Vertical Load Resisting System Design Roof Fran - -Aig111111 Pg= 30 psf ASCE 7-10,Section 7.2 pf= 21 psf Ce= 0.9 ASCE 7-10,Table 7-2 Pfmin.= 25.0 psf Ct= 1.1 ASCE 7-10,Table 7-3 Ps= 25 psf 20.8 plf Is= 1.0 ASCE 7-10,Table 1.5-1 CS 0.5 Max Length, L= 11.92 ft Tributary Width,WT= 20 in Dr= 10 psf 16.67 plf PvDL= 3 psf 5 plf Load Case: DL+0.6W Pnet+Pp cos(9)+PDL= 60.5 plf Max Moment, M„= 560 lb-ft Conservatively Pv max Shear 282.6 lbs Max Shear,V„=wL/2+Pv Point Load = 412 lbs Load Case: DL+0.75(0.6W+S)) 0.75(Pnet+Ps)+PPVcos(6)+PDT= 65 plf Mdown= 604 lb-ft Mallowable=Sx x Fb' (wind)= 1319 lb-ft > 604 lb-ft OK Load Case: DL+S Ps+ PP cos(6)+PDT= 41 plf Mdown= 383 lb-ft Mallowable=Sx x Fb' (wind)= 948 lb-ft > 383 lb-ft OK Max Shear,V„=wL/2+Pv Point Load = 412 lbs Member Capacity SPF#1/#2 2X6 Design Value CL CF C, Cr Adjusted Value Fb= 875 psi 1.0 1.3 1.0 1.15 1308 psi F„= 135 psi N/A N/A 1.0 N/A 135 psi E= 1400000 psi N/A N/A 1.0 N/A 1400000 psi Depth,d = 5.5 in Width, b= 1.5 in Cross-Sectonal Area,A= 8.25 in2 Moment of Inertia, Ixx= 20.7969 in4 Section Modulus,S.= 7.5625 in3 Allowable Moment, Mail=Fb'Sxx= 824.4 lb-ft DCR=M„•/Ma„= 0.44 < 1 Satisfactory Allowable Shear,Vail=2/3F„'A= 742.5 lb DCR=V /Va„= 0.28 < 1 Satisfactory 1/1 _ EWMEOW projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.com Siesmic Loads Check Roof Dead Load 10 psf %or Roof with Pv 27% Dpv and Racking 3 psf Averarage Total Dead Load 10.8 psf Increase in Dead Load 3.3% OK The increase in seismic Dead weight as a result of the solar system is less than 10%of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on information in pictures and a drawing set titled PV plans-JACQUES J PAUL.The analysis was according to applicable building codes, professional engineering and design experience, opinions and judgments.The calculations produced for this structure's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. 1/1 DocuSign Envelope ID: BAE3BED4-1562-4BA1-B74E-830DEA172E76 Sunrun BrightSaveTM Agreement Jacques J Paul 606 W Yarmouth Rd, Yarmouth, MA, 02673 Take Control of Your Electric Bill SO 25 Years $ 190 $0 .260 Deposit due Agreement Term Length Monthly Bill for Year Year 1 Cost per kWh Today (3.5% annual increase One (plus taxes, if applicable; (excluding upfront in monthly bill) includes $7.50 discount for payment, if any) Auto-Pay enrollment) WE'VE GOT YOU COVERED WITH OUR WORRY-FREE SERVICE We provide hassle-free We monitor the system We warrant, insure, Selling your home? design, permitting, and to ensure it runs maintain and repair We guarantee the buyer installation. properly. the system. We will qualify to assume also provide a 10- your agreement. year roof warranty. A SOLAR SYSTEM DESIGN FOR YOUR HOME You gei a ;.49 DC Solar System With 26 Solar Panels and 2 Inverter(s) Which will produce an est. 8,755 kWh in its first year And offset approx.116% of your current, estimated electricity usage YOUR SALES REPRESENTATIVE: Adrian Cadar adrian.cadar@sunrun.com (508) 360-8542 DocuSign Envelope ID:BAE3BED4-1562-4BA1-B74E-830DEA172E76 By signing below. you acknowledge that you have reviewed and received a complete copy of the Agreement without any blanks. Such Agreement shall be the complete understanding between the Parties. SUNRUN Ip.Sik,i,LAWN SERVICES INC. Signature: z- �u .R� �-E316CF746F6A484.. Print Name; Andres vasquez Date: 8/24/2022 Title: prnjPrt npPratinnc Federal Employer Identification Number: 26-2841711 IF YOU CHOOSE TO PAY BY CHECK. MAKE CHECKS OUT TO SUNRUN INC. NEVER MAKE A CHECK OUT TO A SALES REPRESENTATIVE. OUR SALES REPRESENTATIVES ARE NOT AUTHORIZED TO RECEIVE CHECKS IN THEIR OWN NAMES. YOU MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF THE TENTH EFFECTIVE DATE. PLEASE REVIEW THE ATTACHED NOTICES OF CANCELLATION FOR AN EXPLANATION OF THIS RIGHT. Customer *e recount Holder Secondary Account Holder(Optional) ^29iffrifelt4tW Jacques J Paul Signature 8/24/2022 Date Print Name Email Address': jpapouche@gmail.com Mailing Address: 606 W Yarmouth Rd Yarmouth, MA 02673 Phone: (774) 810-1592 Ef:r;d;,au y-Coa a> will i_�B %�d%'by D n!L for ?ft,ca ii.';rJo`,h72;icP, such as 8;di monthly bills or J_he,.1,}. ,v i'85. Sales Consultant By srgrzing e/ow/acknowledge that I am Sunrun accredited that/presented this agreement according to ECode of Conduct and that/obtarned the homeowner's signature on this agreement. O.-5danian. C.a.4an. rITEM Adrian Cadar Print Name 4584611482 Sunrun ID number Sunrun Installation Services Inc. 1225 Bush Street, Suite 1400. San Francisco, CA 94104 1888.GO.SOLAR 1 HIC 180120 Contract Version: 202001V1 Generation Date: 8'222022 Proposal ID: PI<49RK94FVVN-H Version 2021001V1 21 I SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:10220W DC,7600W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), r - SOLAR MODULES •MODULES:(28)LONG!GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SERVICE ENTRANCE PV-1.0 COVER SHEET LTD:LR4 BOHPH-365M INSTRUCTIONS. SIIR P ' " ° PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. SE7600H-USSN •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. MP MAIN PANEL PV-3.0 LAYOUT •RACKING RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY 1 PV-4.0 ELECTRICAL SEE DETAIL SNR-DC-00436 GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. SUB-PANEL SNR MOUNT Co PV-5.0 SIGNAGE •MAIN PANEL REPLACEMENT:EXISTING 100 AMP MAIN PANEL •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SNR MOUNT&SKIRT WITH 100 AMP MAIN BREAKER TO BE REPLACED WITH NEW •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. 125 AMP MAIN PANEL WITH 100 AMP MAIN BREAKER. •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II LC PV LOAD CENTER MODULES,ARE CLASS A FIRE RATED. CHIMNEY • NEW 100A RISER AND METER MAIN •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). SM SUNRUN METER •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). ATTIC VENT •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. •11.43 AMPS MODULE SHORT CIRCUIT CURRENT. PM DEDICATED PV METER FLUSH ATTIC VENT •17.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. PVC PIPE VENT •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(6)(2). METAL PIPE VENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INV INVERTER(S) LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION T-VENT AC AC DISCONNECT(S) SATELLITE DISH DC 0 DC DISCONNECT(S) FIRE SETBACKS CB IQ COMBINER BOX -. HAROSCAPE I--I INTERIOR EQUIPMENT —PL— PROPERTY LINE L J SHOWN AS DASHED SCALE.NTS sunrun _. A AMPERE AC ALTERNATING CURRENT AFC! ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION DC DIRECT CURRENT #180120 (E) EXISTING S•5 MYLES STANDISH BLYD.TAUNTON MA e27110-7.1 ESS ENERGY STORAGE SYSTEM PHONE 0 Q EXT EXTERIOR FAX INT INTERIOR CUSTOMER RESIDENCE: Qyp�b"o Hwy �y5¢8e9'° Nov MSP MAIN SERVICE PANEL 606 W YARMOUTH RD, o« cmv° (N) NEW YARMOUTH,MA,02673 •,,Sop'm� G,a+da NTS NOT TO SCALE OC ON CENTER TEL.(774)208-2154 ' PRE-FAB PRE-FABRICATED APN:YARM-000086-000044 PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC PROJECT NUMBER: RSD RAPID SHUTDOWN DEVICE 223R-6O6PAUL TL TRANSFORMERLESS DESIGNER: (415)580 6920 ex3 TYP TYPICAL MEHARBAN �y V VOLTS � W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET • REV:Al 9/8/2022 - PAGE PV-1.0 ARRAY TRUE MAG PVAREA SITE PLAN-SCALE=1/16"=V-0" PITCH AZIM AZIM (SOFT) AR-01 40° 253° 267° 353 4) AR-02 6' 73° 87° 196.1 (E)RESIDENCE--, (E)GATE --\ \\ AMP \ INV PM sk ---------A OSE - / p' IA. \ \ (N)ARRAY AR-02 SS* S* \ ',, %S ,,, , p (N)ARRAY AR-01-- ,,, ', ° s u n r u n ,,' „IF. �` #160120 - G - `\ ses WALES sr,woisH eLw,rAuurw.MA,onea-rug WOVE 0 . : . , ., ixo -- _ ` 4" L . __ q. '� CUSTOMER RESIDENCE: ? v (E)DETACHED JACQUES J PAUL STRUCTURE 606 W YARMOUTH RD, ../.. YARMOUTH,MA,02673 y p� (E)GATE T+� TEL.(774)208-2154 G, APN:YARM-000086-000044 Z pt O PROJECT 3R-606PAU NUMBER: • DESIGNER: (415)580-6920 e0 MEHARBAN SHEET SITE PLAN REV:Al 9/8/2022 PAGE PV-2.O ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF 11'- RL UNIVERSAL, SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 11" 20" COMP,SEE DETAIL SNR-DC-00436 5'-0" 2'-0" 3'-4" 1'-8" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREWS: AR-02 COMP SHINGLE-RLU 2-Story 2X6 RAFTERS 11.-0" 20" RL UNIVERSAL,SPEEDSEAL TRACK ON 5'-0" 2'-0" 3'-4" 1'-6" STAGGERED 5/16":2.5"MIN EMBEDMENT COMP,SEE DETAIL SNR-DC-00436 STRUCTURAL NOTES: • INSTALLERS SHALL NOTIFY D1-AR-01-SCALE:3/16"=1'-0" ENGINEER OF ANY POTENTIAL AZIM:253° 6" t ___.__.__.._. _....._ __. . 34'-9" _.... --,._ k1,-3" STRUCTURAL ISSUES PITCH:40° OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. • IF ARRAY(EXCLUDING SKIRT) --E3- -f3..._._ ------- 0 -- -❑---._..._. .f]-.. ......_...-----E} -a -0 __.... IS WITHIN 12"BOUNDARY •• REGION OF ANY ROOF PLANE i EDGES(EXCEPT VALLEYS), • THEN ATTACHMENTS NEED E3 ❑ ❑ ❑ 0 ❑ ❑ ❑ TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" 10.-3' BOUNDARY REGION ONLY AS FOLLOWS: ••ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50% Cl n Cl O (l n C]__ �. ••ALLOWABLE OVERHANG I INDICATED ON PLANS TO BE 2'-0" 1/5TH OF ALLOWABLE _I ATTACHMENT SPACING INDICATED ON PLANS D2-AR-02-SCALE:1/4"=1%0" AZIM:73° s u n r u n PITCH:6° t-1" 28.-11" 1' 1 #180120 •e MYLES STANDISH BLVD.TAUNTON.MA,0s700a331 PI-ME 0 FAY 0 STRUCT ; CUSTOMER RESIDENCE: ONL JACQUES J PAUL 403I�H OF Mgsy4c 606 W YARMOUTH RD, ❑ [ ❑ ❑ • I 1 ID6'-10" F� VINCENT y1,, YARMOUTH,MA,02673 ° 0 MWUMVANEZA 5'TYP 1191, CIVIL TEL(774)208-2154 N 1 2 APN:YARM-000086-000044 0 0 0 _Q o �� N°° � EO ��Q °',,fr.;„,,,:"FS. PROJECT NUMBER: 223R-606PAUL • DESIGNER: (415)580-6920 ex3 4' MEHARBAN SHEET LAYOUT REV:Al 9/8/2022 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE / METER A O EVERSOURCE 2290458 UTIUTY GRID /I NEW 100A EXTERIOR BREAKER (\ DISCONNECT WITH 100 A MAIN I ENCLOSURE LOAD SIDE TAP/[.' 1 I (N)LOCKABLE NEW 100A MAIN BLADE TYPE (N)MA SMART SOLAREDGE TECHNOLOGIES: BREAKER FUSED AC UTILITY SE7600H-USSN WITH DISCONNECT REVENUE REVENUE GRADE METERING 7600 WATT INVERTER JUNCTION BOX C3\ METER /1W MODULES �� - g' I T l �'� (2T) OR EQUIVALENT �1� LONGI GREEN ENERGY TECHNOLOGY NEW 125A SUB I _ CO LTD:LR4-6 PANEL _ S,o, ( �. �` _ �� _� �� *��/ (28)ODULESOHPH�65M FACILITY - OPTIMIZERS WIRED IN: LOADS 40A FUSES I 1 (1)SERIES OF(14)OPTIMIZERS SQUARE 0 240V METER SOCKET LOAD RATED DC DISCONNECT L (1)SERIES OF(14)OPTIMIZERS D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT P401 120240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM( CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER I 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 sunrun 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 605 MYLES STAN'DLSH BLVD.TAUNTON.MA 02790-7]31 PHONED FAX 0 CUSTOMER RESIDENCE: JACQUES J PAUL 606 W YARMOUTH RD, YARMOUTH,MA,02673 MODULE CHARACTERISTICS P401 OPTIMIZER CHARACTERISTICS: TEL.(774)208-2154 LONGI GREEN ENERGY MIN INPUT VOLTAGE: 8 VDC AP N:YARM-000086-000044 TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: LR4-6OHPH-365M: 365 W MAX INPUT ISC: 11.75 ADC " OPEN CIRCUIT VOLTAGE 40.7 V MAX OUTPUT CURRENT 15 ADC 223R-0O6PAUL MAX POWER VOLTAGE 34.2 V SHORT CIRCUIT CURRENT: 11.43 A DESIGNER: (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 MEHARBAN SYSTEM SIZE: 10220 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 14 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:Al 9/8/2022 SYSTEM OPERATING CURRENT: 25.55 A SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0 AWARNING INVERTER 1 NOTES AND SPECIFICATIONS: A •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690.OR ELECTRICAL SHOCK HAZARD _ IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE: 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS.•LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABIUTY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:6B0.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(5),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPUCABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(B) WARNING: PHOTOVOLTAIC AWARNING POWER SOURCE LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. -- -- -AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(D)(2),IFC 2012: SYSTEM 605.11.1.4 `LABEL LOCATION: CAUTION ■ UTILITY SERVICE METER AND MAIN SERVICE PANEL. ■ PER CODE(S):NEC 2020:705.12(C) RAPID SHUTDOWN SWITCH AWARNING MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUTCONNECT1ON FOR SOLAR PV SYSTEM 4N� DO NOT RELOCATE THIS - `_/ OVERCURRENT DEVICE LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN LABEL LOCATION: SWITCH PER CODE(S):NEC 2020:690.56(C)(2),IFC sunrun ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3 - - - , - OCPD(IF APPUCABLE). 1----- . PERCODE(S),NEC 2020: 4 705.12 - AWARNING SOLAR PV SYSTEM EQUIPPED mom PANELS PFC.0805 ssr�p�„�w7AU��Mao ,� 7. PHOTOVOLTAIC SYSTEM WITH RAPID SHUTDOWN ON ROOF s. COMBINER PANEL �rouEu DO NOT ADD LOADS r MAIN PANEL (INT) CUSTOMER RESIDENCE: 1 JACQUES J PAUL LABEL LOCATION: _. - J r 606 W YARMOUTH RD, PHOTOVOLTAIC AC COMBINER(IF YARMOUTH,MA,02673 APPUCABLE). • PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) 3 TURN RAPID SHUTDOWN SWITCH TO THE"OFF" AIL INVERTER (EXT) TEL.(774)206-2154 POSITION TO SHUT DOWN PV PRODUCTION METER— APN:vARM-0000e6-000044 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT:31.67 AMPS SHOCK HAZARD IN THE FUSED AC DISCONNECT— 223R-6O6PAUL IIM NOMINAL OPERATING AC VOLTAGE: 240 VAC ARRAY. SERVICE ENTRANCE DESIGNER: (415)560-6920 ex3 LABEL LOCATION: 606 W YARMOUTH RD, YARMOUTH, MA, 02673 MEHARBAN AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. - - -. -- -. - - _ _ _ SHEET PER CODE(S):NEC 2020:690.54 LABEL LOCATION: ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2020:705.10,710.10 S I G N AG E DISCONNECTING MEANS TO WHICH THE PV SYSTEMS _._ ARE CONNECTED. REV:Al 9/8/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0