Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
bld-23-005541
q(47,3 ONE & TWO FAMILY ONLY- BUILDING PERMIT Town of Yarmouth Building Department 1146 Route 28,South Yarmouth,MA 02664-4492 508-398-2231 ext. 1261 Fax 508-398-0836 Massachusetts State Building Code,780 CMR Flo Building Permit Application To Construct, Repair, Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number:, 0-23 _a Ss yi Date Applied: q; Building Official(Print Name) • Signature Date SECTION 1:SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 78 Mattachee Rd 1.1 a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private 0 Zone: — Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Paul Dakin Yarmouth,MA Name(Print) City,State,ZIP 78 Mattachee Rd 781-844-4646 No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK"(check all that apply) New Construction 0 I Existing Building❑ I Owner-Occupied ❑ 1 Repairs(s) 0 Alteration(s) ❑ I Addition ❑ Demolition 0 Accessory Bldg. ❑ Number of Units Other ❑ Specify: Brief Description of Proposed Work2: Install 3.60 kw Hanwha 400 solar panels on roof. 9 total panels. No battery. No structural. SECTION 4:ESTIMATED CONSTRUCTION COSTS. Item Estimated Costs: Official Use Only (Labor and Materials) I.Building $ 3,204 1. Building Permit Fee:$ I SC Indicate how fee is determined: 2.Electrical $ 12,816 0 Standard City/Town Application Fee 0 Total Project Cost3(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees:$ Check No. Check Amount: Cash Amount: 6.Total Project Cost: $ 16,020 0 Paid in Full is Outstanding Balance Due: 0 SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) 01/03/2024 109668 Henry Bratcher License Number Expiration Date Name of CSL Holder 272 Partridge Street List CSL Type(see below) U No.and Street Type Description Franklin,MA 02038 U Unrestricted(Buildings up to 35,000 cu.ft.) R Restricted l&2 Family Dwelling City/Town,State,ZIP / M Masonry �« ?ta.z %z RC Roofing Covering • WS Window and Siding SF Solid Fuel Burning Appliances (508) 808-3704 permittingma@venturesolar.com I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 197479 Venture Home Solar LLC 12/16/2023 HIC Registration Number Expiration Date HIC Company Name or HIC R&Ristrant Name 327 Captain Lewis Ur. No.and Street permittingma(a�venturesolar.eom Southington, CT 06489 (508) 808-3704 Email address City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ❑ No ❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Henry Bratcher of Venture Home Solar to act on my behalf,in all matters relative to work authorized by this building permit application. See attached 4/3/2023 Print Owner's Name(Electronic Signature) Date • SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Henry Bratcher of Venture Home Solar 4/3/2023 Print Owner's or Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.sov/oca Information on the Construction Supervisor License can be found at www.mass.eov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" §TOWN OF YARMOUTH 1146 Route 28, South Yarmouth, MA 02664 508-398-22311 ext. 1261 Fax 508-398-0836 Office of the Building Commissioner BUILDING DEPARTMENT DEMOLITION DEBRIS DISPOSAL AFFIDAVIT Pursuant to M.G.L. Ch. 40, §54 and 780 CMR- Section 105.3.1. #4. I hereby certify that the debris resulting from the proposed work/demolition to be conducted at 78 Mattachee Rd Work Address Is to be disposed of oat the following location: 231 Weaver St Unit E Fall River,MA Said disposal site shall be a licensed solid waste facility as defined by M.G.L. Ch. 111, §150A. 7i4, „ a2� 4/3/2023 Signature of Application Date Permit No. � DATE(MMIDDIYYYY) ACORD CERTIFICATE OF LIABILITY INSURANCE 03/06/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Arthur J.Gallagher Risk Services for CoAdvantage PHONJ.Ext); (866)854-5423 FAX No): Jeffrey Rendel E-MAIL 250 Tequesta Drive ADDRESS: CoI@coadvantage.com Tequesta, FL 33418 INSURER(S)AFFORDING COVERAGE NAIC# INSURER A: American Zurich Insurance Company 40142 INSURED INSURER B: CoAdvantage Corporation 101 Riverfront Blvd Suite 300 INSURER C Bradenton,FL 34205 INSURER D INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:23FL2901009292 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP W LIMITS LTR INSD VD POLICY NUMBER (MM/DD/YYYY) (MMIDD/YYYY) COMMERCIAL GENERAL LIABILITY EACH OCCURRENCEDAMAGE T $ RENTED CLAIMS-MADE OCCUR PREMISES(Ea occurrence) $ MED EXP(Any one person) $ PERSONAL&ADV INJURY $ GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ POLICY PRO- JECT LOC PRODUCTS-COMP/OP AGG $ OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ (Ea accident) ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS --HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY (Per accident) UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ _ $ WORKERS COMPENSATION X PER OTH- AND EMPLOYERS'LIABILITY STATUTE ER A OFFIC R//MEMB REXCLUDED?ECUTIVE YIN N/A WC 10-18-931-04 04/01/2023 04/01/2024 E.L.EACH ACCIDENT $ 2,000,000 (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 2,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 2,000,000 Location Coverage Period: 04/01/2023 04/01/2024 Client# 107330-MA DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Venture Home Solar, LLC dba:Venture Solar Coverage is provided for 2 Kane Industrial Dr only those co-employees of,but not subcontractors Hudson,MA 01749 to: CERTIFICATE HOLDER CANCELLATION Town of Yarmouth SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 1146 Route 28 THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Yarmouth,MA 02664 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/031 The ACORD name and Joao are registered marks of ACORD AC Q® DATE(MM/DDM YY) CERTIFICATE OF LIABILITY INSURANCE 11/15/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Heather Ryan NAME: Protection Plus,Associates Inc PHONE (973)579-6776 FAX (973)579-0111 A/C,No,Extl: (A/C,No): PO Box 4 E-MAIL h an SBOnelnsurance.com ADDRESS: ry 96 US Hwy 203 North INSURER(S)AFFORDING COVERAGE NAIC# Augusta NJ 07822 INSURERA: Southwest Marine&General Ins Co 12294 INSURED INSURER : Endurance American Insurance Company 10641 Venture Home Solar LLC,Venture Solar Electric, INSURER C: AMGuard Insurance Company Venture Solar Capital LLC INSURER D: Selective Insurance Company 327 Captain Lewis Drive INSURER E: NJ Manufacturing Southington CT 06489-1170 INSURER F: COVERAGES CERTIFICATE NUMBER: 22/23 Master#4 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE AUUL SUHH POLICY EFF POLICY EXP LIMITS LTRINSR MAID POLICY NUMBER (MMIDDIYYYY) (MMIDD/YYYY) X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2,000,000 DAMAGE TO REN i ED 100,000 CLAIMS-MADEX OCCUR PREMISES(Ea occurrence) $ MED EXP(Any one person) $ 5,000 A Y Y GL202200012768 11/15/2022 11/15/2023 PERSONAL BADVINJURY $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER. GENERAL AGGREGATE $ 4,000,000 X POLICY X PRO LOC PRODUCTS-COMP/OPAGG $ 4,000,000 JECT OTHER: Per Proj capped agg limit $ 5,000,000 AUTOMOB LE LIABILITY COMBINED SINGLE LIMIT $ 100,000 (Ea accident) ANY UTO BODILY INJURY(Per person) $ C OWN[:D x SCHEDULED Y Y VEAU371260 08/22/2022 08/22/2023 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS XHIRE[I NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY X AUTOS ONLY (Per accident) Un/Underinsured $ 1,000,000 UMBF:ELLA LIAB X OCCUR EACH OCCURRENCE $ 1,000,000 B X EXCESS LIAB CLAIMS-MADE Y Y EXC30000854804 11/15/2022 11/15/2023 AGGREGATE $ 1,000,000 DED RETENTION$ $ WORKERS:OMPENSATION I STATUTE I 10ORH- AND EMPLOYERS'LIABILITY YI N ANY PROPF.IETOR/PARTNER/EXECUTIVE NIA EL.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ If yes,descrioe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ Combined Single Limit $1,000,000 Commercial Auto D Scheduled Auto(7) S2467549 08/22/2022 08/22/2023 Un/Uninsured Motorist $1,000,000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Description of Operations:Solar Panel Installation Certificate holder is included as an Additional Insured to the above captioned General Liability Policy for on-going&completed operations on a primary&non-contributory basis;Additional Insured to the Automobile Policy for work the insured is performing provided a written contract exists requiring such a status. Per the terms of the policy,coverage for an additional insured is contingent upon an underlying written contract with the named insured requiring such coverage. There is a Waiver of Subrogation included in the General Liability,Business Auto,& Umbrella if required by written contract. Umbrella is follow form. 30day notice of cancellation except 10 for non payment of premium. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of Yarmouth THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN 1146 Route 28 ACCORDANCE WITH THE POLICY PROVISIONS. Yarmouth,MA 02664 AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD • AGENCY CUSTOMER ID: LOC#: ACC)REP® ADDITIONAL REMARKS SCHEDULE Page of AGENCY NAMED INSURED Protection Plus Associates Inc Venture Home Solar LLC,Venture Solar Electric, POLICY NUMBER CARRIER NAIC CODE EFFECTIVE DATE: ADDITIONAL REMARKS THIS ADDITIONAL REMARKS FORM IS A SCHEDULE TO ACORD FORM, FORM NUMBER: 25 FORM TITLE: Certificate of Liability Insurance:Notes Company E-NJ Manufacturing-Commercial Auto(NY) POL#1104694823 Effective 08/22/2022-08/22/2023 $1,000,000 Combined Single Limit Symbol 7 ACORD 101(2008/01) © 2008 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations Lafayette City Center 2 Avenue de Lafayette, Boston,MA 02111-1750 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Venture Home Solar LLC Address: 2 Kane Industrial Drive City/State/Zip: Hudson, MA 01749 Phone #: 774-670-2424 Are you an employer? Check the appropriate box: Type of project(required): I.® I am a employer with Full 4. ❑ I am a general contractor and I employees (full and/or part-time).* have hired the sub-contractors 6. New construction listed on the attached sheet. 7. ElRemodeling 2.❑ I am a sole proprietor or partner- ship and have no employees These sub-contractors have 8. ❑ Demolition working for me in any capacity. employees and have workers' 9. ❑ Building addition [No workers' comp. insurance comp. insurance.: required.] 5. ❑ We are a corporation and its 10.N Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.] t c. 152, §1(4),and we have no employees. [No workers' 13.1i1Other Solar comp. insurance required.] *Any applicant that checks box#I must also fill out the section below showing their workers' compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: CoAdvantage Policy#or Self-ins. Lic. #: WC-10-18-931-03 Expiration Date: 04/01/2024 Job Site Address: 78 Mattachee Rd City/State/Zip Yarmouth,MA Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury that the information provided above is true and correct. Signature)46 Date: 4/3/2023 Phone#: 774-670-2424 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(check one): 11:1Board of Health 20 Building Department 3❑City/Town Clerk 4.0 Electrical Inspector 5EIPlumbing Inspector 6.0Other Contact Person: Phone#: THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs and Business Regulation 1000 Washington Street- Suite 710 Boston, Massachusetts 02118 Home Improvement Contractor Registration r,,,; .-- f. ^'. �= j tr. Type: Out of State Corporation o w000mmomero__ I 'egistration: 197476 VENTURE HOME SOLAR, LLC a, Expiration: 12/16/2023 D/B/A VENTURE SOLAR i — • , 327 CAPTAIN LEWIS DRIVE ilk '-_.' , _._. f".!-t/ SOUTHINGTON, CT 06489 7 (` i .4,111W,A4 s , . Update Address and Return Card. THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs&Business Regulation Registration valid for individual use only before the HOME IMPROVEMENT CONTRACTOR expiration date. If found return to: TYPE:Out of State Corporation Office of Consumer Affairs and Business Regulation Registration Expiration 1000 Washington Street -Suite 710 197476 12/16/2023 Boston,MA 02118 VENTURE HOME SOLAR,LLC D/B/A VENTURE SOLAR -,v -----dL"------ ALEXANDER E.YACKERYIS 0 2 KANE INDUSTRIAL DRIVE 11 -",o/GC,' Glo HUDSON,MA 01749 y/ Undersecretary Not valid without signature ...... ...... ...... ...... r Commonwealth of Massachusetts Division of Occupational Licensure j =°`x uildin Re ulations and Standards ; Board of B g�����ir• Constelkt'iton rvisor "` """ " Cpires: 01/0312024 C S 10g668 .e_ HENRY BRATCHER n 272 PARTRIDGE STREET !' FRANKLIN MA 02038 . ` J f-, r Commissioner j1)(1-14-4"' 0° IQ8M and IQ8A Microinverters INPUT DATA IOC) 108M-72-2-US 108A-72-2-US Commonly used module pairings' w 260-460 295-500 Module compatibility 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 33-45 36-45 Operating range V 25-58 Min/max start voltage V 30/58 Max input DC voltage V 60 Max DC current'[module!so] A 15 Overvoltage class DC port 11 DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT DATA IACI ID8M-72-2-US IO8A-72-2-US Peak output power VA 330 366 Max continuous output power VA 325 349 Nominal(L-L)voltage/range' V 240/211-264 Max continuous output current A 1.35 1.45 Nominal frequency Hz 60 Extended frequency range Hz 50-68 AC short circuit fault current over 2 3 cycles Arms Max units per 20 A(L-L)branch circuit* 11 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency X 97.6 97.6 CEC weighted efficiency X 97 97.5 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40°C to+60°C(-40°F to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 lbs) Cooling Natural convection-no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://link.enphase.com/module-compatibility (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. 1O8MA-DS-0003-01-EN-US-2022-03-17 E N P H A S E. DATA SHEET r Ik r� ENPHaSE 'ENPHLS= Ip8A IQ am .., rr� rr. IQ8M and IQ8A Microinverters Easy to install Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- • Lightweight and compact with defined microinverters with split-phase power conversion capability to convert DC plug-n-play connectors power to AC power efficiently.The brain of the semiconductor-based microinverter • Power Line Communication is our proprietary application-specific integrated circuit(ASIC)which enables the (PLC)between components microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times • Faster installation with simple to changing loads and grid events,alleviating constraints on battery sizing for home two-wire cabling energy systems. High productivity and reliability • Produce power even when the Enphase grid is down* • 1 5 • More than one million cumulative i•1E hours of testing year limited warranty • Class II double-insulated Part of the Enphase Energy System,IQ8 Series I08 Series Microinverters redefine reliability enclosure Microinverters integrate with the Enphase IQ standards with more than one million • Optimized for the latest high- Battery,Enphase IQ Gateway,and the Enphase cumulative hours of power-on testing, App monitoring and analysis software. enabling an industry-leading limited warranty powered PV modules of up to 25 years. Microgrid-forming 41r (2) • Complies with the latest advanced grid support** CERTIFIED • Remote automatic updates for SAFETY the latest grid requirements Connect PV modules quickly and easily to IQ8 Series Microinverters are UL Listed as • Configurable to support a wide I08 Series Microinverters using the included PV Rapid Shut Down Equipment and conform range of grid profiles Q-DCC-2 adapter cable with plug-n-play MC4 with various regulations,when installed • Meets CA Rule 21(UL 1741 SA) connectors. according to manufacturer's instructions. requirements ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,I08 Microinverters, •Only when installed with IQ System Controller 2, and other names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. •*IQ8M and 108A supports split phase, IQBMA-DS-0003-01-EN-US-2022-03-17 240V installations only. MECHANICAL SPECIFICATION Format 74.0 in x 41.1in x 1.26 in(including frame) (1879mm x 1045 mm x 32 mm) 74n•(1#79 mm) {---4]a•P0lr mml ss.s•nuns m'"1 Weight 48.51bs(22.Okg) _ I � Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass with 4- uz aom'") i anti-reflection technology 0-11---1- 4.Orou*.points.01r(9b'"m) INC.- Back Cover Composite film Our(ure mm) Frame Black anodized aluminum Cell 6 x 22 monocrystalline Q.ANTUM solar half cells sir0045mm) Junction Box 2.09-3.98in x 1.26-2.36in x 0.59-0.71in(53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes Label y^Iu .422.ueomm> Cable 4 mm2 Solar cable;(+)z 49.2 in(1250mm),(-)z49.2 in(1250mm) ~~o ...imp.d.°1 iln 9+MdrY.Iw(DETAIL A) 4.I , Connector St8ubli MC4;IP68 Ur na men) DETALLA a.."a.'"'") o.oa')2uamm)I-(,)Ia.9r(11.Smm) ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 400 405 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5 W/-0 W) Power at MPP' PM11 [W] 385 390 395 400 405 E Short Circuit Current' Isc [A] 11.04 11.07 11.10 11.14 11.17 E Open Circuit Voltage' Vac [V] 45.19 45.23 45.27 45.30 45.34 5 Current at MPP IMPP [A] 10.59 10.65 10.71 10.77 10.83 Voltage at MPP VMPP [V] 36.36 36.62 36.88 37.13 37.39 Efficiency' fl [%] z19.6 z19.9 z20.1 z20.4 z20.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT' Power at MPP PMm [W] 288.8 292.6 296.3 300.1 303.8 E Short Circuit Current Isc [A] 8.90 8.92 8.95 8.97 9.00 .1. Open Circuit Voltage Vac [V] 42.62 42.65 42.69 42.72 42.76 Current at MPP IMPP [A] 8.35 8.41 8.46 8.51 8.57 Voltage at MPP VMPP [V] 34.59 34.81 35.03 35.25 35.46 'Measurement tolerances PL,PP±3%;Isc;Voc±5%at STC:1000 W/m',25±2°C,AM 1.5 according to IEC 60904-3•'800W/m',NMOT,spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE F M° -0CELLS �� At least 98%of nominal power during !m ' r l n .. """ tlei� first year.Thereafter max.0.5% 2 . degradation per year.At least 93.5% fee L of nominal power up to 10 years.At W I cz least 86%of nominal power up to > i 1 , 5 o w 25 years. e So r r - i z 2 0 All data within measurement tolerant- ` I iri es.Full warranties in accordance with t0 ' the warranty terms of the Q CELLS 200 900 MO NO uoo o n sales organisation of your respective IRRADIANCE tWim<] N country. .m.aw..�....-M.mww+. „ YEARS Typical module performance under low irradiance conditions in . •"°."°°°"°°'°".0.,i30.law SM.1n comparison toSTC conditions(25°C,1000W/m') Fi TEMPERATURE COEFFICIENTS b 0 Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of Voc 6 [%/K] -0.27 1, Temperature Coefficient of PMPP y [%/K] -0.34 Nominal Module Operating Temperature NMOT [°F] 109±5.4(43±3°C) m 0 PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage Vs, [V] 1000(IEC)/1000(UL) PV module classification Class II o Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 n Max.Design Load,Push/Pull3 [Ibs/ft1 75(3600 Pa)/55(2660 Pa) Permitted Module Temperature -40°F up to+185°F o Max.Test Load,Push/Pull' [Ibs/ftl] 113(5400Pa)/84(4000 Pa) on Continuous Duty ( 40°C up to+85°C) u io 'See Installation Manual I QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION sl • UL 61730,CE-compliant, I'' 4 J I T J Ib [ n Quality Controlled PV-TUV Rheinland, ® �� 11/ \I111/// �sl/ O-O I40HC IEC 61215:2016,EC 61730:2016, U.S.Patent No.9,893,215(solar cells), C Tavlx.wm Horizontal 76.4in 43.3in 48.01n 16561bs 24 24 32 QCPV Certification ongoing. C US ` packaging 1940mm 1100mm 1220mm 751kg pallets pallets modules memo ID 11112.7/ y Note:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha Q CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1 949 748 59 96 I EMAIL inquiry@us.q-cells.com I WEB www.q-cells.us powered by Q.ANTUM /DUO/© • • I 1 t 1 i 11 { 1 Q. PEAK DUO BLK ML-G10+ 385-405 ENDURING HIGH PERFORMANCE YR EUPD RESEARCH=. 000.251 �+ TOP BRAND PV MODULES EUROPE Warranty 2021 0 CELLS Product R Perrombnce Yield Security �Jn�n BREAKING THE 20%EFFICIENCY BARRIER nl 11 ll l Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new'Quality Controlled PV'of '✓`�` the independent certification institute TUV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY 0 )): Optimal yields,whatever the weather with excellent low-light and temperature behavior. O _ ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology,Anti PID Technology',Hot-Spot Protect and Traceable Quality Tra.QTm. EXTREME WEATHER RATING High-tech aluminum alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). 20 A RELIABLE INVESTMENT ? ,YEAR:(,' Inclusive 25-year product warranty and 25-year linear performance warranty2. 'APT test conditions according to IEC/TS 62804-1:2015,method A(-1500V,96h) 'See date sheet on rear for further information. THE IDEAL SOLUTION FOR: `J Roos on residentialftop buildings Engineered in Germany CE«S venture solar ® 03/22/2023 Paul Dakin 78 Mattachee Road Yarmouth, Massachusetts 02664 Re:Solar Panel Installation Dear Mr./Ms. Dakin, At your request, Patrick Bussett of Venture Solar LLC(MA license#56934), has carefully reviewed the existing roof framing and the proposed connection of the solar panels to the roof for the building referenced above. The following building codes were used in conjunction with the 9th Edition of the Massachusetts State Building Code—780 CMR to generate pertinent design criteria: ASCE 7-10—Minimum Design Loads for Buildings and Other Structures International Building Code 2015 Edition (IBC) National Design Specification for Wood Construction 2015 Edition (NDS) Design Criteria: Design Gravity Load: Snow/Live Load =30 lbs/ft2, Dead Load= 12 psf Design Wind Load: Vuit=140 mph; Exposure B, Risk Category II *Wind loads exceed seismic loads and therefore govern the design Field observations identified the following conditions: The new solar panels will impose an additional dead load of approximately 3 psf.The roof consists of asphalt shingles over plywood sheathing supported by 2x6 rafters at 20"o.c.The rafters are sloped at a 25° pitch and have a maximum projected horizontal span of 12'-0"±.The framing is assumed to be Douglas-Fir#2 graded or better. The calculations determined that the existing framing has adequate capacity to support the PV panels as shown in our PV panel layout plan with no structural upgrades required. I therefore certify that this installation complies with the applicable codes and is acceptable for approval. Please feel free to contact me if you have any questions or concerns. Best, (-s-cPNOFAiit ti / /�.U)3-2- ' PATRICK \�+ BUSSETT No. 56,34 / Patrick Bussett, PEj]u2- . Email: patrick.bussett@venturesolar.comSlONAL '\ venture solar ® 03/22/2023 Paul Dakin 78 Mattachee Road Yarmouth, Massachusetts 02664 Re:Solar Panel Installation Dear Mr./Ms. Dakin, At your request, Patrick Bussett of Venture Solar LLC(MA license#56934), has carefully reviewed the existing roof framing and the proposed connection of the solar panels to the roof for the building referenced above. The following building codes were used in conjunction with the 9th Edition of the Massachusetts State Building Code—780 CMR to generate pertinent design criteria: ASCE 7-10—Minimum Design Loads for Buildings and Other Structures International Building Code 2015 Edition (IBC) National Design Specification for Wood Construction 2015 Edition (NDS) Design Criteria: Design Gravity Load: Snow/Live Load =30 lbs/ft2, Dead Load=12 psf Design Wind Load: Vuit=140 mph; Exposure B, Risk Category II *Wind loads exceed seismic loads and therefore govern the design Field observations identified the following conditions: The new solar panels will impose an additional dead load of approximately 3 psf.The roof consists of asphalt shingles over plywood sheathing supported by 2x6 rafters at 20"o.c. The rafters are sloped at a 25° pitch and have a maximum projected horizontal span of 12'-0"±.The framing is assumed to be Douglas-Fir#2 graded or better. The calculations determined that the existing framing has adequate capacity to support the PV panels as shown in our PV panel layout plan with no structural upgrades required. I therefore certify that this installation complies with the applicable codes and is acceptable for approval. Please feel free to contact me if you have any questions or concerns. Best, _ - N OF�ASs9cti 4 / .CUJ/.Gtil PATRICGn CDBUSSETT v No. 56,Q34 / / Patrick Bussett, PE m Email: patrick.bussett@venturesolar.co �`� SS/ONAtt° DocuSign Envelope ID:694012D7-86B2-4760-A6BD-BB13BA060366 YOUR venture + SYSTEM , . , , 0 • i ir 0 TRIPLE-BLACK venture+ venture - venture , SOLAR PANELS MICROINVERTERS MONITORING SERVICE PLAN YOUR VetL ,. SYSTEM WILL PRODUCE 3 346 kilowatt hours of energy per year. EN PHASE microinverters included standard. Hanwha QCelis 400 DocuSign Envelope ID:694012D7-86B2-4760-A6BD-BB13BA060366 1. 1 ' ,. , . nture.,.. . Congratulations! so ar You're on the way to saving with solar $ 0 Upfront kWh Payment3 3 4 6 Annually Annual Monthly 0 % Increase 5 9 1 2 Payment Customer Signature: /-DocuSigned by: PAUO • CB0F313CB2B0486._ DocuSign Envelope ID:694012D7-86B2-4760-A6BD-BB13BA060366 venture solar Letter of Authorization / Property Owner Authorization Form I, Paul Dakin, am the owner of the property located at address: 78 Mattachee Road, Yarmouth, MA, 02664 I hereby authorize Venture Home Solar, I_LC dba Venture Solar Power of Attorney to handle dealings associated with the successful interconnection and application for obtaining local building and other permits from the Authority Having Jurisdiction as required for a Solar Photovoltaic System located on my Property. I further authorize you to release my account information for the prior twelve (12) months, including electrical usage and demand history. Venture Solar agrees to keep this information confidential and use it only for the purposes of designing, installing, and interconnecting my photovoltaic system, obtaining incentives on my behalf, and establishing interconnection agreements, proper metering, and approvals. Print Name: Paul Dakin —DocuSigned by: Owner Signature: ea O 'I^, `—CB0F313CB2BD486.. 3/8/2023 Date: Print Name: Paul Dakin DocuSigned by: �A���`Utility Bill Owner Signature: [`'�" I.tlUb 5IJUI3ZUL9 b Date: 3/8/2023 DocuSign Envelope ID:694012D7-86B2-4760-A6BD-BB13BA060366 sunn va Sunnova Energy Corporation 20 Greenway Plaza,Suite 475 Houston,TX 77046 1.866.SUNNOVA(786-6682) customerservice@sunnova.com HOA Confirmation for Access and Solar Installation 1. The real property at (Street Address) (City) (State) (Zip) (the"Residence") is subject to deed restrictions which include the appointment of a Homeowners Association ("HOA"), (Name of HOA) 2. I am authorized to make the following representations on behalf of the HOA, and the representations are true and correct. 3. The real property, including the roof, of the Residence is owned by the homeowner. The roof is not community property under applicable deed restrictions and is not owned by the HOA. 4. The HOA does not restrict and will not restrict access to the roof of the Residence. 5. There are no deed restrictions preventing the installation and maintenance of a solar photovoltaic system on the roof of the Residence. 6. The HOA will not intervene, object to or otherwise restrict any transfer of title of the solar photovoltaic system. HOA Representative's Signature HOA Representative's Title HOA Representative's Name DATE Form Effective 4/8/2020 DocuSign Envelope ID:694012D7-86B2-4760-A6BD-BB13BA060366 venture solar Venture Solar Damage Liability Addendum for PV Installations Customer: Paul Dakin Installation Address: 78 Mattachee Road, Yarmouth, MA, 02664 Venture is liable to pay for damage to your real property caused by our negligence during your installation. We shall not be liable for damage to the system's installation area due to old, deteriorated, or improperly installed roofing, sub-roofing, roof coverings, supports, siding, exterior paint or covering, or other non-visible installations. In the event that you suspect there may be damage to your property caused by our installation please contact us immediately at 347-305-7999 or email support@venturesolar.com to schedule an on site inspection of the damage. Venture may elect to hire a sub-contractor to repair the damage. After we conduct our inspection of the alleged damage, we will contact you with a plan to correct the damage. If you elect to use a contractor other than Venture to repair the damage without written consent from Venture, we reserve the right to not reimburse you for the damages. Our total liability shall be limited to the amounts due payable to Venture under your agreement. Except as set forth in this addendum, you agree there are no oral or written representations or inducements, exp-essed or implied, any way conditioning this addendum, and we expressly disclaim their existence. By signing this addendum, you acknowledge that you have read and understand this agreement or have had a competent legal representative explain its terms, and hereby accept this addendum in its entirety. You further acknowledge receiving a complete copy of this agreement. —DocuS gned by: 3/8/2023 PAtt. Pettit —CB0F313CB2BD486. Signature Date support@venturesolar.com 347.305.7999 DocuSign Envelope ID:694012D7-86B2-4760-A6BD-BB13BA060366 venture solar Venture Solar System Removal Addendum for Residential PV Installations Customer: Paul Dakin Installation Address: 78 Mattachee Road, Yarmouth, MA, 02664 If you elect to have your solar energy system removed and re-installed in the future there will be a charge of$325 per panel to remove, store, and re-install the PV system. If you elect to have the system removed, but not re-installed there will be a charge of$220 per panel. This pricing is valid for 120 months from the date of signature. Venture guarantees the penetrations related to the solar PV system and the area 6" around them for 10-years, but takes no responsibility for the roof or it's integrity otherwise. Except as set forth in this addendum, you agree there are no oral or written representations or inducements, expressed or implied, any way conditioning this addendum, and we expressly disclaim their existence. By signing this addendum, you acknowledge that you have read and understand this agreement or have had a competent legal representative explain its terms, and hereby accept this addendum in its entirety. You further acknowledge receiving a complete copy of this agreement. c—DocuSigned by: Pad. V IL 3/8/2023 caOF313rR7RD48s Signature Date In the event that you suspect there may be an issue with your roof, please contact us immediately at 800-203-4158 or email support@venturesolar.com to schedule an on site inspection. support@venturesolar.com 347.305.7999 DocuSign Envelope ID:694012D7-86B2-4760-A6BD-BB13BA060366 , Venture Solar Customer Cancellation Addendum This addendum is in relation to the solar photovoltaic installation agreement ('Agreement') between Venture Home Solar,LLC('Venture')and Paul Dakin('Owner')to take place at 78 Mattachee Road, Yarmouth, MA, 02664 ('Site'). Venture and Owner may individually be referenced herein as a 'Party' or collectively as the 'Parties'. TRANSACTION DATE: March 8, 2023 YOU MAY CANCEL THIS TRANSACTION WITHOUT ANY PENALTY OR OBLIGATION, WITHIN SEVEN (7) BUSINESS DAYS FROM THE ABOVE DATE. TO CANCEL THIS TRANSACTION, FOLLOW THE INSTRUCTIONS IN THE SECTION BELOW. The following cost schedule is enforceable if the Owner chooses to cancel their project: Cancellation Timeline Fee • Within seven (7) days of signature $0.00 • Between eight (8) and thirty (30) days of signature $1,275.00 • Outside of thirty(30) days of signature $2,675.00 • Within two (2) days of scheduled installation $4,750.00 Your signature below indicates your agreement to the timeline and fee schedule in the event you choose to cancel your project post signature. CDocuSigned by: paUt Pat«n, 3/8/2023 fr C130131303?DD400 Signature Date In the event that you wish to cancel, please sign below and email a copy to cancelrequest@venturesolar.com. The cancellation fee will be based on the date above and the date that the copy is received via email. I, Paul Dakin, wish to cancel my solar installation with Venture Home Solar, LLC and agree to pay the fee associated based on the time passed from entering the installation agreement. Signature Date support@venturesolar.com 347.305.7999 DocuSign Envelope ID:694012D7-86B2-4760-A6BD-BB13BA060366 venture solar Balance of System Acknowledgement: 78 Mattachee Road, Yarmouth, MA, 02664 t" 3 , 1 4 . 4 ' "'37 ti-air"H"%:**„ . • rt I. I'ti, t 1.^ : ,i a 1 x ly *erg ,� �'�'� ,,,+r i „���" e 4 ^,'�i •�,", �, I, Paul Dakin, acknowledge that Venture Solar will need to install electrical equipment on my home as part of my solar energy system. Venture Solar will make best efforts to ensure that the system is installed in an aesthetically pleasing manner while adhering to required building and electrical codes. , DocuSigned by: P �a�I�n 3/8/2023 Signature: Date: `—(.BUl313l.b2BU466... DocuSign Envelope ID:694012D7-86B2-4760-A6BD-BB13BA060366 Q HomeWorks ®n ( Energy Venture Solar& HomeWorks Energy Partnership Venture has partnered with a local Mass Save Energy Efficiency contractor to maximize savings available to our customers who are choosing to switch to solar. As a part of this partnership, you are eligible to have a free home energy audit that will include no cost energy efficiency upgrades. During the energy assessment we will determine which upgrades you are eligible for. The assessment is a short, painless process that we can help you schedule online. This is an option available to you at no cost, and is in no way required for your solar project. Most of our customers find this to be a valuable service if they have not already had a home energy assessment. After your assessment, you will receive a report. You will be eligible for no cost air sealing, and have options for weatherization measures with a nominal co-pay if you elect to have those measures installed. You can begin scheduling your home energy assessment here: https://www.homeworksenergy.com/corporate/venture-solar/ DocuSign Envelope ID:694012D7-86B2-4760-A6BD-BB13BA060366 venture sotar Referral Program In our tier based system, you earn more for referring more people. Starting with $500 per referral, you move up tiers to make up to $1,000 per referral. 0 Yes, enroll me 0 I don't want to help my friends/family 0 I don't have friends Referral 1: Referral 2: Referral 3: Referral 4: Referral 5: Initial Here 1 L rl�� tt. ti : BRONZE SI V R AI .60 Bronze Tier: Silver Tier: Gold Tier: 1-3 referrals 4-5 referrals 6+ referrals $500 each $750 each $1,000 each DocuSign Envelope ID:694012D7-86B2-4760-A6BD-BB13BA060366 , Aurora Shade Report Customer Designer Organization Paul Dakin Vipul Pradhan Venture Solar LLC Address Coordinates Date 78 Mattachee Road (41.645890,-70.214023) 9 March 2023 Yarmouth MA 02664 Annual irradiance kWh/m2/year 2,450 or more 2,100 t 1,750 Q I 1,400 4 , -- . 1,050 * g.1 4 350 e # y { o ar +`. 0 4> Summary Array Pane!Count Azimuth(deg.) Pitch(deg.) Annual TOF(%) Annual Solar Access(%) Annual TSRF(%) 1 9 274 25 83 75 62 Weighted average by - - - - panel count 74.5 61.9 Monthly solar access(%)across arrays Array Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1 31 53 79 86 81 83 82 85 84 61 38 27 DocuSianed by: 3/8/2023 Pa Vatik, CB0F313C8280486... 1 i3 powered by aurora DocuSign Envelope ID:694012D7-86B2-4760-A6BD-BB13BA060366 Customer Designer Organization Paul Dakin Vipul Pradhan Venture Solar LLC Address Coordinates Date 78 Mattachee Road (41.645890,-70.214023) 9 March 2023 Yarmouth MA 02664 Zoomed out satellite view 3D model # YI. ini ::. I ,.,.., _ ..,,,, 4_, 1/ ii i ffi k * a 3D model with LIDAR overlay '' 13 ft *Ail i 'i z-,.> it *4 f ' u . Vim '66 . r ram_„ �! `ag �. 9 4 Vi 4) 2/3 powered by 4/i aurora DocuSign Envelope ID:694012D7-86B2-4760-A6BD-BB13BA060366 Customer Designer Organization Paul Dakin Vipul Pradhan Venture Solar LLC Address Coordinates Date 78 Mattachee Road (41.645890,-70.214023) 9 March 2023 Yarmouth MA 02664 Street view and corresponding 3D model i f •,,ii, 78 Mattachee Rd t " ` . r 'I A, Yarmouth,Massachusetts �►f`4 L �' L 1 _ .17, " ::-""'"H-Ii*::.- ,...... _ :: • } fi e Goo9Ie._ - y . - _ 0 2023 Google * . . `- i -4.4.` • ,, ..,6 i a r t ._ . .„ e . lit,if'40*,,:". ti,; s r 4. %� 4 t' r IRA:., . n r..._. ._ .._—,,,, I,Vipul Pradhan,certify that I have generated this shading report to the best of my abilities,and I believe its contents to be accurate. 3/3 powered by aurora • venture solar SOLAR ELECTRIC GENERATION INSTALLATION ON EXISTING RESIDENCE: 17m-.P..bANP_ �M Bw MA 78 Mattachee Rd, Bass River, MA 02664, USA SCOPE OF WORK 02664,USA SCOPE OF WORK IS SOLELY SWIM u.anti wo OF THE SOLAR PSI)M.R-LellQ SITE PLAN EdrA,-IxomPopAS BEING APPROVED AND/OR OTHER WORK IS NOI'ro RE Imes PotlR EN)I..R.m Ua.eu{I.PF A.aIA! RFLFD UPON AS BBINO APPROVED AND/OR PERMITTED BY THE RIX PUIDB.Maddn Sale,r w RV BUILDINGS DBPARTMNP. Imam(OP)KISPLvsYr wS Micro-m eat. Saes SY.mm DC Sias 3.60KW AC SRA 2.611CW NOTES Saes Amoel PDac6m:7316 KWH the,.,m coo,O,a,nl rAir p,..pn.ar irw wilF rhr rlrr nr& Designed By:UNIRAC wiAkrrr perifird m wxr s N0.0f.Aar 6ern,marn dry Date:____ analyzed and A w ar An delrnnmed tole capable o1rappnrnn* l ,;,,, 7,/ ,,,(- R' nR+l'xrm�ar der Gel,A. dr irerxarl rMral....... -_ (S /•` ?/ ,�1�� ImG r Tkerel Mzordrzha lryW conmrt - - i'C> r y:,/.,li. SYAan,,-4-.ralar 1,—,,lrmnmgryI10 :I•U•V •1 W ' => k �j C: l I.l APPLICABLE CODES y/` - - (,jJi ✓. <' ,,1 -, ‘' AR waw-ed work shell mew we R R .p r amwe �{ ' MA State OE EC lCode MHOA CMR Mellon . • ;A i f C t... Y RBIs IntenutiM Reaideotial code with MA Amenment,) - -' hI 'p ]DIS Wood Frame Contraction Manual RrM_ -.ea'. 9:d6 !r h Y ,- t % Y f`i a .71 I�iP' 1. LCt `1 - ln'�`.h.� �t�ii>. �'��',F ,", I X „��1 .l _ C "'3@, 4a' : 4 ..�1 G"k';.. ' �'��..c L' yr MAP OF BLOCK DISTRICTS .5- it x . f <> L �'' >.1, �., a '- S • ./', ; , i- Proposed Micro-Inverters t I c,,�- i ,. . o 0� Integrated solar Panel Installations Ski Pic,i I ^ ' ' _ DDY e ( _ ^ M R•QP" •"^ "-' '.t >�: � was- — Existing Main Service Panel i° 0 Location:Inside Basement Petrick Bowel Venture Soles Bro 78 MattacheeRd. Ill cLLo Existing Automatic Transfer 6]Wnt Bt nse•RPM n NY I,mSotto YamWuth,MA A Existing Chimney Switch Location:Inside Basement �5NOF114I,a,kbYe RN,, oz664,uDNBa sT�eB _ proposed location Combiner box:Outside ��� PAIRICR sscyN .1../ C' r a Proposed location AC Disconnect:Outside r ',,.{.-'`C .k ' r vJ rV/5,i ,_, No.S634 a GPS COORDINATES tU ; ,1 ! ,' 'New Tap Box Location:Outside \A .�, , ,,• 41.645914,-70.214028 b\ -: d e i✓ A ,v. � . ,, k �xisang Utility Meter Location:Uu[siae pNAIUF DRAWING INDEXjC -_ 'l .1 ,n- \ { E ' ., I Rain baesm.eoe,Site Elm LOOMS LL )v'V 1�'j z,T { y A I �J y `'-;-` ) ,`I, , ✓ ' T PAmA Ramp/Kimura x Mendota ma System Amara ��c /2 t� )d>7 __• ,v� , - ,,4, 1 Y,r�I�r l>'d i i/ X`J / 1 ResffiSmd,atldWem. &MOOD (, ✓ ,k' /• -r-` 7 4�T�C - . _X, i �i0 /J'.(OYJ� 3 Label.a Soles Map PL.ud OOSDO I ?? t,:. )? S. � ✓ ;:�� ,i DOB SiMWSiPa-Dm f So-Mg Oi.Vr BOOOJD } r, Y l ( ) \ ^K 1, 7 Lid Rea DSLAO I�• , 1 (\.}� . �' - r 1 I `i I m-midwm.•Law. B.Bozao '('c C l_:i > ' ,xl.`f ' e Y 9 eoM amLdo `� � k� �� Ci _.�._ C- tZ {/ ,'' i .T C 1 C s_ --. per' i_.._r .,\; ..j, ; Proposed Addition L./ Existing Driveway Dusting Buildues A ZONING INFORMATION, '.4., SITE PLAN Fr. venwanmm -� Existing Tree(Typ.) Z400•00 a 0 Obmtram N Mules 411--1'-0' Bp I.H venture solarSYSTEM LAYOUT ELEVATION LEGEND .w..realm ern r1 V,16^mt Pipe. U a^ ,12^T.II aoe3m.w 78 MattecMe Rd Bass River,MA O Veot Boo 02664,USA Pool 3 Mathis Sni6mee C) Veer Pm solar ea(9)Ilu„n.Qc.491Q.PaAewA2 BM 111A110.9iils Irma..:(W)IQIIPI.US73-2413 GHvoi.van Sar31.m DC Sic 3.6111CW AC Sk..:26110/ Wu Anneal P1oHlelm:3,346 KWH B,,,gnv6Bj U Proposed Micro Inverters Doc Integrated solar Panel Installations SnYW3 Apprw.lOm Bmr43a Existing PVC Pipe �/f/�y Existing Attic Vents .111111 ROOF A �� Q)H AQ-CELLQ. %� / Existing PVC Pipe iii DUOtiu-cio«t�Q� j%j Existing Sky Light o TILT: is7an j% Existing PVC Pipes 0 � / / Existing Main Service Panel o '1� ■ Location:Inside Basement u^ 1 Gliti Existing Automatic Transfer n00 Switch Location:Inside Basement 111111 Existing Chimney Proposed location Combiner box:Outside Proposed location AC Disconnect:Outside New Tap Box Location:Outside Existing Utility Meter Location:Outside Existing Satelli /N Pend(Borne Vcniurc Solar Proposed Solar Panel Array V Wu(S4 Brooklyn,NY I Proposed Solar Panel Array pme6S63 Microinverters integrated with the panels Microinverters integrated with the panels Nor ■ I �� Ws�Os / BIRYTT 'I 1 =�NMI N3. a — pNAL 6"Min. 6 PV AC .� P.EJAA.Sump/Swatter — — Disconnect 4 P4 Existing Utility Meter New Tap Box Enphase combiner panel with PV monitoring ELEVATI IAYOUT SYFI'eM OELEVATION NORTH WEST O ELEVATION SOUTH WEST A-000.00 __ (FRONT SIDE OF HOME) (RIGHT SIDE OF HOME) Sale:3/16^.P Page 2e19 venture solar UNIRAC STAGGERED STRONGHOLD _ LEGEND ROOF ATTACHMENT 09. 40.110.19.4,1011 mot.air r t'-o• MN Fmk II xa 78 Mattacbee Rd,Base River,MA rnno- '� 02664,USA • xrr60091(Nn5 Paul 5 D,kin',RdiJcncc ----- eM�e B.l.pia(m .o.&Q-r.norrazunotr- Roof A ,ten r°..,.atwl paPl.usn-2-us xtw°r...,o Acceptable Rail Mounting Area Sotto Solar DC Ms:a6LSCW Acse.utcW 8,_10" 18,_8n 3'— L-Feet Rail Supports shall be installed at each Solar Mona ed Byt Production cove Designed er uNauc + end of rail and every 40"there after to support De.:3/23/2923 1 I 1 1 1 all Solar array wind and snow loads.Roof LMiatm9 'Me,P,YU„e a..4Bm + t t i t Err attachments shall be staggered. I I I I 1 I 1 I I , ♦ e ♦ ' ♦ ; ♦ ' ♦ ' • I 1 I ! �1, 1 13' t ! ' ! t 1 0 ; t t • ' •: : • : i I • • 1 •• 1 1 I t ! ♦ ♦ • ! ♦ ♦ • t 3' 30'-6" Unirac Stronghold Attachment @40"O.C. 2"X6"Rafters @20"O.C. Patrick Boa. Vaduz Boar 67 West Sl.&nokbn.NY 11222 lica°u a 56934 �4 6OF Y,4s( )) ROOF STRUCTURAL DETAILS: r PAiaicr BUSSETT RC OP TII T:31° 4111100. �)\ ilk Ridge Beam 2"X6"Rafters @20"O.C. PP.IBA.s,.my8wd 1p )iid , • Unirac Stronghole � • ,At\r t7�'( • Installation ,ro„�, k,i •• �\ ooe smwale...,. \ \ '2'\ />'" \ \ ' \. .) 6"Min'• �/ I I do RACKING AND LOAD CALCULATIONS The PV modules will be maximum 6"off the roof surface. S-000•OO Swb:SEE SCALE Page 3d9 Venture solar" NXT HORIZON RAIL STRONGHOLD INSTALLATION NXT HORIZON RAILS MAX.SPAN _- S 1Il6'-1.0' Sale:UA6'-10 sod. nS.� ®HORIZON U N I RAC a N.nl Maximum Continuous Spliced Rail Length for NIT Horizon p1n1tl'AB •• fir MKS erAa2 Rail with Stronghold Attache(the)(fL)/Maxklaan Reaction 78 M.malee Rd,Boa Rives,MA r rl„ ,,,r.�«. L`F'J� PM MOUTON _ 02664,USA YEAR s1GMxlo1-NS SmeNWgIn ATT mew oRll ela) Force(Ws) ftia , DISCOVER YOUR NXT HORIZON _Ir 311°Nl°I sTooNfaaluATTKITCOOCa( -- 9UMrPab:�lna6etµoule. xuw ry 9M[PxIM116 9,NONg101DATr f!]IP I�L(NA AtratlMAaMSWtklg M Nn.nIM Module. treua Im61 I ucxl r 1930191 as3m, gyp•' ,� ^'°.,.., rut+�iu AT I'F) 24' 4B' 72' inv.m.:(09)IQorc u6-TLLUS MI�odae.en •99 N p UU CIA Wry(i All a 411.�X1911 UN.Me pAUW41I1 &Ansi...a Sls 3601CW AC 51.:2.611CW IMMFaG Iwh lbI ne IIhI RYIIGRELNI9119 KK119391 """"" • 40 67/155 94/218 117/272 Ydv Annual Production A6 EMI MFeanl.;Yut Ott nYuu 50 59/171 86/250 105/305 Designed BT UNUAC .�..... 60 55 191 78 272 93/324 DMe:3rz�mz3ION ^----"-- m• tE ' 70 51/207 70/285 81/329 a.m... Moot De s cooloice i „-.•-.1 t BO 47/218 62/288 80/372 90 43/225 62/324 69/361 I'—:ow' f -`_ _.3 """ I y 100 43/250 54/314 64/372 � "* 140 35/285 45/366 45/366 cj 'J '— ' Maximum Continuous Spliced Rail Length for NXT Horizon ........ .....- ryx-�.- �- .�I « Y Rail with Flaahkit P_r4 Attachments(ft.)/Maximum Reaction tit,at •x.. .. Force(Ws)- - _ - _ N I w AT('� 24' Attachment Spacing 72' -�..._+�'-'.4...' ,.__..._.._ -_.. •- .�, ,_..._.. —.r R ciao„(MOM,.A,NrA 40 75/139 102/189 129/239 N ALL N21 NORNON'MIDIS IMAM pEKE YIXNIIING npNStI UISIGX fa 9G[$I11Nt OR Ln1041H anuFYISII<NIflAGtUN UP Ma NSIYlNMIn:UNIRAG CUM 50 67/175 94/218 117/271 60 63/175 86/239 105/292 70 55/178 78/253 , 93/302 s'UNIRAC 4I4Me rer11pc12ON 'INAN1NG NC CN 30S ?' 80 51/189 70/259 93/345 ""n"�0M5'"B 90 51/213 70/308 81/338 uu aoow..aw.x DIAVANG TIM PARTS ASSEM0. MINA Y NOL 633409L1,NNAnmus. oawv1041, NG161.B v6oaxT.nrtcrt9 Nr 100 47/218 62/287 80/371 RCM 95.111,6111 - -- 91II90.399 ?.-. as OR MORE US aTBm 120 43/239 62/345 66/367 AACnx NM..LNI REVISION GATE: 9/22/2021 LEGAL Nona SHOT ' 140 39/253 54/350 57/370 INVERTER SPEC-SHEET COMBINER BOX SPEC-SHEET PV MODULE SPEC-SHEET Sole:ln67.1-0• sob:1/16'-I t" ro commN.r vpc Format 74.0 in x 41.1 in x 1.26 in(including frame) KM andioe.Microinverters (1879mm x 1045mm x 32mm) 1 Patrick Bumf] -;.- ..-, ... - ^ ..^ .. ..^^ Weight 48.5Ibs(22.0kg) G,ww.:S<B,4 pin,: 1.22 --••••^ --- _.-._,- ...........-.. Front Cover 0.13 In(3.2 mm)thermally pre-stressed glass with "' "' e^1 anti-reflection technology +�`3xOFY.48,r4 -- ..-��r Back Cover Composite film _ + P67RCK yTA 6 Frame Black anodized aluminum o au�frt „ u No.56 34 n ... ".-..._i'.......... Cell 6 x 22 monocrystalline Q.ANTUM solar half cells ...,...,.. ...._....._..�...... � dam�4. . —•-- Junction Box 2.09-3.98 in x 1.26-2.36In x 0.59-0.71in L u . .. (53-1.01mm x 32-60mm x 15-18mm),IP67,with bypass diodes MIAA 9.194 SFpaM. - �- - - — Cable 4mm2 Soler cable;(+)t49.21n(1250mm).(-)>_49.2in(1250mm) • ...,.. Connector Stiubli MC4,IP68 ........,.,. 3nx2a29 .-m....� u ,........................,aa. DOB SUMO SiaMay. a..N..e. _. SPREADsfEITT .- �„ S-001.00 his 4al9 venture solar CT M.A AW,.HY Ilia 78]Aa"ach--Rd,Base River,MA 02664,USA Paid S D.kWs Residence Solar Pane s:09)Hameln 12i'sll U.P.AR DUO 1Ymea.:(09su)IQOPI sn2 .0.BBMa. Labels comply with NEC 110.21(B)and ANSI Z535.4 Soles Synem DC Sim:3.601(W AC Sv<:2.61RW Sehe Annual Production:3.306 KWH Detintted By.UNIRAC Dee:3R3/2023 _ Rewluaa Awemo1D., IWNWPWew COMBINER PANEL JUNCTION BOX AC Output Current:10.89A COMBINER PANEL A WARNING Nominal Operating AC Voltage:240V ELECTRIC SHOCK HAZARD.THE DC CONDUCTORS OF THIS AC DISCONNECT PHOTOVOLTAIC SYSTEM ARE AC Output Current:10.89A A/C DISCONNECT UNGROUNDED AND MAY BE Nominal Operating AC Voltage:240V ENERGIZED COMBINER PANEL A CAUTION MAIN DISTRIBUTION PANEL A WA "` �,, INVERTER OUTPUT CONNECTION; DO NOT RELOCATE THIS TWO POWER SOURCES INSIDE OVERCURRENT DEVICE UTILITY AND SOLAR PV 1 JUNCTION BOX WARNING:PHOTOVOLTAIC POWER P.BckBm u SOURCESoler Yahoo Brooklyn.CONDUIT EVERY 10 FT 6]Wul S(Brooklyn NY 1122 L cenee R 36930 ���.,`N OF Id4S,in CAUTION : °RISSER Si �o N9. N SOLAR PV SYSTEM EQUIPPED POWER TO THIS BUILDING IS ALSO ‘1...., /say ; WITH RAPID SHUTDOWN SSOURC S WIPPLIED OTH D SCONNE FOLLOWING pma.Vr' ) LOCATED AS SHOWN: ry...R..,on,,,,... zt. MIA.Sap/Signs.. lW -.9�.J' RV SYSTEMAND REDUCE ,,r ARRAY OR ROOF �/ li Ve' upr. Ct ' ' ,G// 3/23/B)23 v ", DOB Stamp/Slp,mna .c ��� TRANSFER u !!! SWITCH Noio a.l wH:..reM V. TO.TIC m .. °WINER PANEL USED AC MECT TAP FRU .) urr METER LABELS G-000.00 Soles MIS Pane 5 A9 venture solar' meet eTnm String Diagram 78 Manachee Rd,Base River,MA 02664,USA PeY S Dabs'.Residence Selr Pave.:(09)H.nrk.te-cell V.PHAR WD RI C M1.e110l2-US Inverters:(09)I°SPLUS-R Micro-2-US Micro-In.enm Sdn System DC Sim 3.60KW AC Sin:26lKW Sete Annual Production:3.346 KWN Deesoed BY:UNIRAC DM:3232023 Revising@ ADOov.lDate Deerlp9ee Enphase IQ8PLUS-72-2-US Micro-Inverters ROOF A 0 (09) HANWHA Q-CELL Q.PEAK DUO BLK ML-G10+(400W) = AZIMUTH: 274° 4 5 6 ° TILT: 31° 10 LL , • ■ P.tnck Mews Venture Solar 62 Wen St,Brooklyn NT 11222 o 0 License 9 ..K * Cy M TB A C 2 PAS 17, RISSER NO.5934 ti L PIJR.A.Stenpr/Sipruee 0 DOB Sum*Sipreve. String 1 _ String Diagram -1 • E-000.00 So k NTS Pap 6.49 venture solar' Labels Sheet enema Nam Br„m 78 Matter-bee Rd,Bus River,MA 02664.°SA String Number Module Number Sticker Pap/S Daki1'6 Rcdideece Balm PBteU:fB9)HmwNO1ddule.YEA1C3111U BLC3DAIB-2-VS i 3oodK(9333Qs9l.Ds-n-x-us rn�Bo-3B.mBa Eohe Spun DC Sias:3.60K W AC Ss:261KWY Wm Annual Production:3,N6 1C39t1 Designed By:UNBIAC D.x:]23/3023 ambles• Appwal Dou DoBBIBo 1 • 3 4 1 5 Meek W 062 Soles 67 Wut A4 Brooa klyn NY 11222 License 956934 r40`�NOF MAs�n 6 2 PAIRICK cloussur M939.54 /ONAI 32y1023 DOB Sump/Bloom* 8 9 Label Sheet E-001.00 Saks NB Pp7d9 • • venture solar PURE SIZE CA AT 6 MODULE SPEC-SHEET CONDUCTOR SIZING CALCULATION AMBIENT CURRENT(09)x 12u1121.1i63A.c 60Atm sine '""". ...... CIRCUIT DESCRIPTION CURRENT Imu(69I(W) l.m(690.Nx2xo sPP.t>P® AI000TOV• 7ga 7wtE o CONO.oP USE AIRPI� w.sNB.mr.lrc aaN - - m ek CONDUCTOR WC eC COND. (6m.1BBx3xb)nlc ' ,"" -- _ PR801nnIR0101 9m W6 10.8)a 125.L3.61 110IDING a 2630 1a �ceway(stab.temp) 1.0 70 MRuachee Rd,Bus River,MA ''- - •. (raceway(D b.temp•1 02664,USA 87KEIGC.V.CIBATW9A - COMBINER 10x 1a PIT 9.m Sass IO.Ka125_13/1 K'I31MN-2 39 2630 1-1 33* n Gomm BO soma)lB Pod S D.Un.Residence (09)x 121A x 125.13.61A QUA—"OK �.7`.� AC DISCONNECT OUTPUT 9.00 1049 11109 135_13.61 06INWN-2 75 2630 1-3 73A x 1.0(mb Neel B lA noimnnen:(09)Nmwea Q-Can QPD. AKDlA9 .�' ......._ -::..,. a (=wary BR).75.00A RIRMI-MID Mr.. ^^� In...:(00)IQ3PLUS-72-2-1.15 Miaa-Inmin Sat.System DC Sine:3.601CW AC So:2.61KW Solar Annul Production:3.346 KWH Designed By:UNIRAC Due:3/23/2023 Re W im 0 Approrsl Due Desedplm String 1 ROOF A Self Bonding Panel and Rail $Dlar Pon. String I Line 1 (W)non..o-css a PEAR 09 o B.Mt-mo.(400R) __ String 1 Line 2 LJ S' 1 Ground (1)LI Red MI0 Copper Conductors THWN-2 1)ACPV Cables (1)L2 Black 010 Copper Conductors THWN-2 (1)Grounding Green N6 Copper Conductors THWN-2 Conduit Length of Conductor:15' Length of Conduits:15' r EMT Aluminum Conduit 1 So1.DaTk Nod to Equipment Junction Box Note:— Add New Top Box ROOF TOP SIDE OF BUILDING BASEMENT SIDE OF BUILDING (l)LI Red R10 Copper Conductors THWN-2 (1)L2 Black P10 Capper Conductors THWN-2 (1)LI Red 06 Copper Conductor THWN-2— Line side mtacomMchon (1)L2 Black 46 Copper Conductor THWN-2 (I)gth ofCgGreen R6 Copper Conductors THWN-2 Insulated Terminal Blocks (1)NeaDal N6 Copper Conductor THWN-2 Length oIC d-lor:ts' Length of l minum:lo Geld (1)LI N6 Capper Conductor THWN-2— (I)Grounding CreenN6 Copps Conductor TIJWN-2 I"EMT Aluminum Cendtl¢ (1)1,2 N6 Copper Conductor THWN-2 Length of d tor:05' O (1)Neutral M6 Copper Conductor 71iWN-2 Length off Coroeadads:05' Length of Conductor:1W 1"EMT Aluminum Conduit •. ,. ILength of Coeidmta:,0 A Paining Utility 1 EMT Aluminum Conduit .-.. Meter Socket TAP BOX _Oa ll. AT _I(New Net Morel `� Meter N 2306930 DEB LZ V Account 0l4%I 3111 00/6 LiO C-� faker Dams ATS yy 120260V 1.11., � 60A New Exterior125A 1. IEaphue IQ Combiner 4 O (X-IQ-AM1-240-4) 0D0 stmeal o waoaee. ing Existing With rting Ne o at rid Square D 100A Using Grounding Screw New Damien N AC DMCotNRCT • Aa 120240V MT.3101.10003 Main Panelel 60A NC aaoaeaa,Eaton 00n3909 (Io.. (1)Grounding 06 Conduct= RAd..fauwtr Meal • I,�(1)Grounding N6 12"GEC Water M' Cc... ELECTRICAL 3-LINE& LABELS E-002.00 Seek NTS Page 8 of9 venture solar „r,„„n, VENTURE SOLAR n.,b,..ea m. 78 Mauchee Rd,Bass River,MA Customer Name Paul S Dakin 02664,usA Customer Address 78 Mattachee Rd,Bass River,MA 02664,USA Paul SDakina Q.{UQc Mar YamY:ISC kr�e MeaQ.PRARDUO Team UNIRAC ...err(09RISC IQQIPLUSna-uS Miao-k,n . Soli System DC Sian 3.6011W ACSise:161KW ROOF ELECTRICAL Solar newel Production:3.aw Kwx Description Qty. Bar Code Description Qty. Bar Code Designed By)UNIRAC P P Date:VW}J Hanwha 400 9 Enphase IQ Combiner 4 1 Revitlooa Approval Doe Description Portrait Q Cable-#Conn 0 Enphase Mobile Connect 1 Landscape Q Cable-#Conn 11 Enphase IQ7 Micro 0 Q Term 1 Enphase IQ7+Micro 0 Q Seal 3 Eaton 20 A Breaker 1 Q-Conn 10M 0 IPC-4/0-#6(Taps) 2 Q-Conn 1OF 0 60 A Disconnect 1 Micro Inverter T Bolt 10 60A Set of Fuses 1 Wire Restraints 1 100 AMP Disconnect 0 Ground Lug 3 100A Set of Fuses 0 Pitched ROOF 125 A Combiner Panel 0 Strong Hold Box(Qty.20) 2 Square D 100 A Main Breaker 0 Unirac Rail 9 Square D 20 A Breaker 0 Unirac Splice 6 Square D 15 A Breaker 0 Unirac Ends 13 Enphase IQ Envoy 0 Unirac Mids 13 Enphase IQ7A Micro 0 Solar Seal 1 Enphase IQ8 Micro 0 Solar Deck 1 Enphase IQ8+Micro 9 Consumption CT x 1Sets 100 Enphase IQ8M Micro 0 Fire and Smoke detector x 1 No No Enphase IQ8H Micro 0 Battery Details Manufacturer Type Mfr.Part No.&Description Qty Enphase Energy Inc Battery ENCHARGE-10T-1P-INTAC Battery 0 Enphase Energy Inc Other EP200G101-M240US01 Enpower 0 Enphase Energy Inc Moniter COMMS-KIT-01(Ensemble) 0 FLAT ROOF CONFIRMATION Chemlink 6"E-curb Kit 0 L-Foot Box w/Nut&Bolt(Qty.24) 0 4"Stand Off 0 Procurement Team Signature Unirac Tilt 18-30" 0 DOD Dower Sipomx.. Unirac Tilit 26-44" 0 Unirac Tilit 40-72" 0 Crew Foreman Signature Silver Unirac Rail 0 Silver Unirac Splice 0 Silver Unirac End 0 Silver Unirac Mid 0 4"Lag 0 BOM 8"x8"x4"Junction Box 0 G-001.00 — S.k:MS Page 9M9