Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD-23-003076
. , , • .. , 'of..Ydi BUILDING PERMIT APPLICATION . . . •-• • - '$' APPLICATION TO CONSTRUCT, REPAIR, RENOVATE, CHANGE THE USE,OCCUPANCY OF, • --. . } ) .•. ..0 ,.,.. •: . ,.. ..1c OR DEMOLISH ANY BUILDING OTHER THAN A ONE OR TWO FAMILY DWELLING. 0 - —-3 -,ETown olYarmouth Building Department a, pukl-r..CriCE • A''''' \‘-"DD 4'.....1/W1... .6 I 14f Route 28 • Yarmouth, MA 09156-1-1492 •:1.4...; • Tel: 508-398-2231 ext. 1261 Fax 508-398-0836 Office Use Only Planning Board Information Assessors Department Information: al)-23—bb3t)-7b Permit No. Date Plan Type Map Lot . A I' ' Permit Fee $.0) )k 0 cA Endorsement Date / Li DOC. A Deposit Rec'd. $ Lii011) te Recording Date 1.4 Property Dimensions: New Plan No. P.C3 ..)- Net Due (1-71-16 Other Lot Area(sf) Frontage(It) Lot Coverage • • This Section for Office Use Only Building Permit Number ______ 1 Date Issued: Signature: . • . Certificate of Occupancy ' ----7-- - Buildin tficial ' Date is Is not R E Cti V E D Section 1 - Site Information 1.1 Property Ad rags: igserii & dd 1.2 Zoning Information: ,.. NOV 30 2022 46u e tiu.LI curvviouil Zoning DistrictBU I lidA44i@siiril/jsqM E NT 1.3 Building Setbacks(ft) ' Front Yard Side Yards I Rear Yard Required Provided Required Provided I Required Provided 1.4 Water Supply(1.l.Q.L.c.40.S 54) 1.5 Rood Zone Information: Comments _ Public Private Zone: BFE ' Section 2 - Property Ownership/Authorized Agent 2.1 Ownar of Record: AT&T VVIRELESS 208 S Akard St,Dallas,TX 75202 Name(print) Mailing Address: AGENT (210)821-4105 • Signature Telephone Telephone Email Address: ./ 2.2 Authorized Agent: ADAM WOLFREY-CENTERLINE COMMUNICATIONS LLC AUTHORIZED AGENT 750 W CENTER ST STE 301-W BRIDGEWATER MA 02379 Name (print) Mailing Address: -,../..... ..7. AGENT 508-667-3100 . Signature Telephone Fax Email Address: I • Section 3 - Construction Services 3.1 Licensed Construction Supervisor: . Not Applicable 0 ERIC KUKLINSKI CS-097477 License Number 1089 MAIN ST-WAREHAM MA 02576 Address AGENT .508 742 8472 enc.kuklinski@ericsson.com Expiration Date Signature Telephone Email Address: - . • 3.2 Registered Home Improvement Contractor. Company Nemo Not Applicable 0 Registration Number Address Expiration Date Signature Telephone Section 4-Workers'Compensation Insurance Affidavit(M.Q.L c.152 S 25C(6) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes X No Section 5- Professional Design and Construction Services-for Buildings and Structures Subject to Construction Control Pursuant to 780 CMR 116(containing more than 35,000 c.f. of enclosed space) Section 5.1 Registered Architect: Not Applicable 0 Name (Registrant): Registration Number Address Expiration Date Signature Telephone Section 5.2 Registered Professional Engineer(s) Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name • Area of Responsibility Address Registration Number Signature Telephone Expiration Date Namo Area of Responsibility Address Registration Number Signature Telephone Expiration Date Section 5.3 General Contractor Not Applicable ❑ Company Hama • Person Responsible for Construction Address Signature Telephone Section 6 - Description of Proposed Work (check all applicable) New Construction ❑ (tor multiple family only) No.of Bedrooms (for multiple family only) No.of Bathrooms Existing Bidg. ❑ Repair(s) ❑ Alterations 0 Addition ❑ Accessory Bldg. ❑ Type I Demolition Other Specify: - 1 Brief Description of Proposed Work: ON BEHALF OF AT&T THE PROPOSED WORK INVOLVES INSTALLING THEIR EQUIPMENT AT THE EXISTING CELL SITE. • • Section 7- Use Group and Construction Type Building Use Group(Check as appficapable) Construction Type A ASSEMBLY ❑ A-1 ❑ A-2 o A-3 ❑ 1A ❑ A-2 0 A-5 ❑ 18 ❑ B BUSINESS ❑ 2A ❑ E EDUCATIONAL ❑ 2B ❑ F FACTORY ❑ F-1 ❑ F-2 ❑ 2C ❑ H HIGH HAZARD 0 3A ❑ I INSTITUTIONAL ❑ 1-1 ❑ 1-2 ❑ 1-3 0 33 ❑ M MERCHANTILE ❑ 4 ❑ R RESIDENTIAL I ❑ R-1 ❑ R-2 ❑ R-3 ❑ s ❑ S STORAGE ❑ 5-1 ❑ 5-2 ❑ 55 0 U UTILITY ❑ SPECIFY: • M MIXED USE ❑ SPECIFY: S SPECIAL USE ❑ SPECIFY: Complete thissection if existing building undergoingrenovations,additions and/or change iri use. Existing Use Group: Proposed Use Group: Existing Hazard Index 780 CMR 34 Proposed Hazard Index 7B0 CMR 34 Section 8 Building Height and Area • Building Area Existing(if applicable) Proposed Number of floors or stories include basement levels Floor Area per Floor(st) Total Area All Floors (sf) Total Height(ft) Section 9 - STRUCTURAL PEER REVIEW (780CMR 110 11) Independent Structural Engineering Structural Peer Review Required Yes No SECTION 10a OWNER AUTHORIZATION -TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT ADAM LLC , as Owner of the subject property, , AADAM H.OLFREY-CE hereby authorize INOLFREY AADAM DAGENTNTERUNECOMMUNICATIONSLLC CO act on my behalf, in all matters relative to work authorized by this building permit application. AGENT 1111&22 Signature of Owner Date • • SECTION 1 Db OWNER/AUTHORIZED AGENT DECLARATION ' I, AUTMAGECENTERLINECOMMUNICATIONSLLC AUTHORIZED AGENT , as Owner/Authorized Agent hereby declare that the statements and information on the forgoing application are true and acurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. ADAM WOLFREY.CENTERLINE COMMUNICATIONS LLC AUTHORIZED AGENT • Print Name • ad!c/.L'. AGENT • • 11/18/22 Signature of Owner/Agent Date Section 11 - ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be completed by permit applicant 1.Building 525.000 2.Electrical 3.Plumbing/Gas 4.Mechanical(HVAC) 5.Fire Protection 5.Total=(1+2+3+4+5) 7.Total Square Ft.(ix new ssLcnaes b aadibxes) $25.000 Check Below 0 Conservation-Commission Filing (if applicable) ❑ Old Kings Highway&Historical Commission approval (if applicable) • . A' y7� : x�4 - ilti • • • ,i- a 'm� .� 6 s? «s xN . _ 1 + tI � �y : ' ,w0O Mmex� mg � tt�i .O -..<",,!.:1:.,,,..1..:,,,!•• ry � ,: .Atk^ ' CteC�F, a E.Qf;:!:::-,:'::,'::'':4"-c'::.:,:.,:;,,.::,,,., C ° _ 04„.tii:,,,;,:','.:,.,.::,,t,:',',...,',:l.,..1-714111-.....:,:-'..,,,,.:'..:..:':!!'.,',::.,:.1..,7,......,:•:::',4.,.T.:i0„...-.4.,':'„,-;,.4",:,''''..fii.:1:..... `11qas C n ,-x °� gi +F s&. - to i,, , m �a,�, stQ � ��Y 4S �A oma'sI .......,..::.,,,,,,:o..::- . �a O yµw� ee. • � i �k � ��„ � � il!-P$iI�&_ipq �,,,Au�' �$ wg�o ¢��:, �^ a ,i a fl 1. t .. ACORODDIYYYY) ® CERTIFICATE OF LIABILITY INSURANCE DA/ETE(M(MoM/ kr.,....---- THIS .....THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Marsh USA,Inc. NAME: PHFAX 4400 Comerica Bank Tower (AIC No,Ext): (A/C,No): 1717 Main Street E-MAIL Dallas,TX 75201-7357 ADDRESS: Attn:dallas.certs@marsh.com 212-948-0519/866-966-4664 INSURER(S)AFFORDING COVERAGE NAIC# CN101764695-GAWU-22-23 INSURER A:ACE American Insurance Company 22667 INSURED INSURER B:ACE Property&Casualty Insurance Company 20699 Ericsson Inc. Attn:Timothy Shires INSURER c:ACE Fire Underwriters Insurance Company 20702 6300 Legacy Drive INSURER D:Indemnity Insurance Company of North America 43575 Plano,TX 75024 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: HOU-003578792-12 REVISION NUMBER: 1 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SU BR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER (MM/DD/YYTY) (MM/DD/YM) LIMITS A X COMMERCIAL GENERAL LIABILITY X . HDOG47353762 11/01/2022 11/01/2023 EACH OCCURRENCE $ 2,000,000 CLAIMS-MADE n PREEMMGETOCCUR PRO R6N rLD ISES(Ea occurrence) $ 1,000,000 MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 4,000,000 X JE POLICY n PRO-CT n LOCI PRODUCTS-COMP/OP AGG $ 4,000,000 OTHER: $ A AUTOMOBILE LIABILITY ISA H10766928 11/01/2022 11/01/2023 COMBINED SINGLE LIMIT $ 1,000,000 (Ea accident) X ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURYPer accident $ AUTOS ONLY _ AUTOS ( ) HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY _AUTOS ONLY (Per accident) _ — $ B X UMBRELLA LIAB X OCCUR X XEUG27975422008 11/01/2022 11/01/2023 EACH OCCURRENCE $ 5,000,000 EXCESS LIAB CLAIMS-MADE AGGREGATE $ 5,000,000 DED RETENTION$ $ D WORKERS COMPENSATION WLR 050735084 11/01/2022 11/01/2023 x PER OTH- AND EMPLOYERS'LIABILITY YSTATUTE ER ANYPROPRIETOR/PARTNER/EXECUTIVE n E.L.EACH ACCIDENT $ N/A • (AOS Except:AZ,CA,MA&WI) 1,000,000 G OFFICER/MEMBER EXCLUDED? • (Mandatory In NH) SCF C5073500A(WI) 11/01/2022 11/01/2023 E.L.DISEASE-EA EMPLOYEE $ 1,000,000 A If yes,describe under WLR C50734936(AZ,CA,MA) 11/01/2022 11/01/2023 1,000,000 DESCRIPTION OF OPERATIONS below E1.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) The following are dependent upon policy terms and conditions,where required by contract,operations of the named insured and to the extent permitted by law,With respect to the Commonwealth of Massachusetts and Department of State Police,Additional Insured status is provided on the General Liability and Umbrella Liability policies per the Blanket Additional Insured Endorsements. CERTIFICATE HOLDER CANCELLATION Commonwealth of Massachusetts SHOULD ANY OF.THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Department of State Police THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 340 West Brookfield Road ACCORDANCE WITH THE POLICY PROVISIONS. New Braintree,MA 01531 • AUTHORIZED REPRESENTATIVE I ::Z Cc 22.S7 '?etc. ©1988-2016 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD §TOWN.OF:Y�RMOUTI3 1146 Route 28;-'South:.Yarmouth, MA 02664 508-398-223I...e t -:1261 Fax 508-398-0836 Office of the.:Building Commissioner ai BUILDING DEPARTMENT DEMOLITION DEBRIS DISPOSAL AFFIDAVIT Pursuant to M.G.L. Ch. 40, §54 and 780 CMR- Section 105.3.1. #4. I hereby certify that the debris resulting from the proposed work/demolition to be • conducted at 17 SEA GULL ROAD WEST YARMOUTH,MA 02673 • • Work Address Is to be disposed of oat the following location: 206$Akartl St.Dallas.T%75202 Said disposal site shall be a licensed solid waste facility as defined by M.G.L. Ch..111, §150A. Ad UJ. :y AGENT 11n&22 Signature of Application •Date Permit No. • I .,_ -..,..._- \„,„‘.., ,,,-,:-..) 550H ROAD FRAMINGNGHAM MA, 01701 ! 0 CENTERLINE AT&T SITE ID: CRAN RCTB MCAPE 113 ' 750 WEST CENTER STREET, SUITE# 301 NODE FA: 15351216 WEST BRIOCEWATER, MA 02379 USID: 297509 =i 17 SEA GULL ROAD NORTHEAST WEST YARMOUTH, MA 02673 459EEC""°°°°°"ENORM ANDOVER M°'°.3 TEL 1978I 55>-5553 SHEET INDEX VICINITY MAP(NOT TO SCALE) GENERAL NOTES 4' '�N OF M4SS9cti . - pANIEL P. SHEET DESCRIPTION REVNO. . . +� _ . 1 �, 1 <3' / M —i 40, a* r zr 1. THIS DOCUMENT IS THE CREATION, DESIGN, PROPERTY AND COPYRIGHTED WORK OF AT• / C _, T-1 TITLE SHEET 1 � w -"� e , �' ANY DUPLICATION OR USE WITHOUT EXPRESS WRITTEN CONSENT IS STRICTLY PROHIBITE.. 0.4a7 0 r _ `4 *{ 40 t DUPUCATION AND USE BY GOVERNMENT AGENCIES FOR THE PURPOSES OF CONDUCTING THEIR ,�. '' .+° . _ ' '" >3 �°'' LAWFULLY AUTHORIZED REGULATORY AND ADMINISTRATIVE FUNCTIONS IS SPECIFICALLY ALLOWED. • ,p �- GN-1 GENERAL NOTES 1 ` , ; ,g4r I"• ;y, * �O ect$TEftC �'' "+ a '.71," •-Ar , - 2. THE FACILITY IS AN UNMANNED PRIVATE AND SECURED EQUIPMENT INSTALLATION. R IS ONLY S/ �� A-1 KEY PLAN AND COMPOUND PLAN 1 i'' ": , .;T. w # i,_+ f., k ` .' ACCESSED BY TRAINED TECHNICIANS FOR PERIODIC ROUTINE MAINTENANCE AND THEREFORE ONAE� 4zia` e. 4 V « DOES NOT REQUIRE ANY WATER OR SANITARY SEWER SERVICE. THE FACIUTY IS NOTIVO A-2 PROPOSED ANTENNA LAYOUT 1 , " , Yn. " m ' fi� - ^O.— •.• GOVERNED 6Y REGULATIONS REQUIRING PUBLIC ACCESS PER ADA REQUIREMENTS. CHECKED BY: AT ;;'k`to :' iia "' 9 ...'• .. • * .A ''a° A-3 EQUIPMENT DETAILS 1 1 ; Y w r a ' "' R 3. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE g,�s " t ,, 'ILA � JOB SITE AND SHALL IMMEDIATELY NOTIFY THE AT&T MOBILITY REPRESENTATIVE IN WRITING OF I APPROVED BY: DPH I +y', 17 Se WI d e, "y DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. E-1 ELECTRICAL EQUIPMENT DETAILS 1 �` *, r1t, p` G-1 GROUNDING DETAILS 1 •: ' ", '.'7 '''''7 ' rIf' I wi j 4. CONSTRUCTION DRAWINGS ARE VALID FOR SIX MONTHS AFTER ENGINEER OF RECORD'S SUBMITTALS "- " PROJECT +b 3 N+ STAMPED AND SIGNED SUBMITTAL DATE LISTED HEREIN. OESCIWPREN BYPROJECT DESCRIPTION T' *"'; " �E ", *;,..'-.4.4.;-• .V. 4.416q.,--V '" 'fib. H,, .. » "'- ,-.1 4'+w."``. ,16 I. INSTALLATION OF ANTENNA AND ASSOCIATED EQUIPMENT ON EXISTING GUYED h" !"~ $ " %.H � �A A* +^ TOWER. �f 1 'r. -'3 k- R " 4E4,.;a � "i! ': ti" o ►. .. DO NOT SCALE DRAWINGS 2. THIS IS AN UNMANNED AND RESTRICTED ACCESS EQUIPMENT SITE AND WILL BE R s'r kms,., " V ' _ i.,1",‘"(..;$' 1 V''',,q2.1.),d j V 1 11/10/72 ISVFDFOR COrmRunwN a USED FOR THE TRANSMISSION OF RADIO SIGNALS FOR THE PURPOSE OF 'r 1"."'^ .K'�Y, CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND o 11/W/72 ISSUED FON REVIEW a IMPROVING CELLULAR AND WIRELESS INTERNET SERVICE. # )AA< r �7 # '' ,' "` ""�' .Y //72 .$ '' 1 „e s SHALL IMMEDIATELY NOTIFY THE PROJECT OWNER'S REPRESENTATIVE IN WRITING OF DISCREPANCIES BEFORE A 10 n 691FD FOR RDnE'1 a 1f5 k ,t,��(� . .± ^ ' .tom y , "" a; , �°"r''".,`� ��'.. PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. �a1� ..**%,�$Jr. "� • #•2r-,-r�.�,r,.�' .-"4'"�,x;�' y.ia'.^� CLUSTER AND NODE NUMBER: PROJECT SUMMARY DRIVING DIRECTIONS UNDERGROUND SERVICE ALERT CRAN_RCTB_MCAPE_113 SITE ID: SITE ADDRESS: 17 SEA GULL ROAD TO HUB LOCATION: CRAN_RCTB_MCAPE_113 WEST YARMOUTH, MA 02673 RT 128 SOUTH TO RT 3 SOUTH. GO ACROSS THE SAGAMORE BRIDGE TOWARDS THE CAPE. FOLLOW SITE ADDRESS: RT 6 EAST TO EXIT 6 RT 132. BEAR RIGHT AT OFF RAMP AND FOLLOW RT 132 TO HYANNIS 17 SEA GULL ROAD AIRPORTp WEST YARMOUTH, MA 02673 COUNTY: ROTARY. TAKE BARNSTABLE ROAD OFF THE ROTARY AND FOLLOW TO MAIN STREET UGHTS. GO ; 7 BARNSTABLE COUNTY BARNSTABLEIII ACROSS MAIN STREET AND ON THE RIGHT IS SEACOAST MOTEL. TURN IN DRIVEWAY AFTER �/jam. I SEACOAST D` AND FOLLOW AROUND THE VERIZON BUILDING TO THE LEFT. SMALL BRICK BUILDING IS OUR SITE 1 \ SHEET TITLE LATITUDE: 41.635469' N (41' 38' 7.69" N) LONGITUDE: 70.234703' W (70' 14' 4.93" W) DiOSafe TITLE SHEET IV MA-ME-NH RI-VT STRUCTURE TYPE: GUYED TOWER SHEET NUMBER ARCHITECT/ENGINEER: WWW.DIGSAFE.COM HUDSON DESIGN GROUP LLC T-1 45 BEECHW000 DRIVE 72 HOURS PRIOR NORTH ANDOVER. MA 01845 I 1 Uf n a d m C C) r) 11 Co n oo� 3� 3 *orn d c Oa .-. 3 m c'-o'x A m d o = c-' N' y to C1 p o . J Zt'fa� Na o' *Dx v EL. -i v= g m e mzNx (1 0co_ 3 e ' O t! G n = w x '�+ 7 ....to O O C f�C .A.fto N n � ,� .... a W , m , N O i � M dam a ft, -4YiN ..Ao cc'cp Cc3 ;•/ os o ?G C A A I .'Y y N _ R Y � M A A1, 7,- , N. 0. r - "-. p, N r H ?` - _ a Y • GROUNDING NOTES GENERAL NOTES WITH AISC SPECIFICATIONS. ALL STRUCTURAL STEEL SHALL BE ASTM A36 (Fy = 36 ksi) 1. THE SUBCONTRACTOR SHALL REVIEW AND INSPECT THE EXISTING 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: UNLESS OTHERWISE NOTED. PIPES SHALL BE ASTM A53 TYPE E (Fy = 36 ksi). ALL STEEL 4�`� FACILITY GROUNDING SYSTEM AND LIGHTNING PROTECTION SYSTEM (AS EXPOSED TO WEATHER SHALL BE HOT DIPPED GALVANIZED. TOUCH UP ALL SCRATCHES AND �' at8(t DESIGNED AND INSTALLED) FOR STRICT COMPLIANCE WITH THE NEC (AS CONTRACTOR - CENTERLINE OTHER MARKS IN THE FIELD AFTER STEEL IS ERECTED USING A COMPATIBLE ZINC RICH PAINT. ADOPTED BY THE AHJ), THE SITE-SPECIFIC (UL LPI, OR NFPA) LIGHTING SUBCONTRACTOR - GENERAL CONTRACTOR (CONSTRUCTION) 16.CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND "GENERAL CONSTRUCTION SERVICES 550 COCHHUATE ROAD PROTECTION COAND GENERALECO AC WITH TELCORDIA AND TIA OWNER - AT&T MOBILITY FOR CONSTRUCTION OF AT&T SITES." FRAMINGHAM,MA 01701 GROUNDING STANDARDS. THE SUBCONTRACTOR SHALL REPORT ANY 2. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING SUBCONTRACTOR SHALL VISIT THE CELL VIOLATIONS OR ADVERSE FINDINGS TO THE CONTRACTOR FOR RESOLUTION. SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN 17.SUBCONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO 2. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE RADIO, LIGHTNING PROTECTION, AND AC POWER GESS) SHALL BE BONDED SHALL BE BROUGHT TO THE ATTENTION OF CONTRACTOR. DRAWINGS MUST BE VERIFIED. SUBCONTRACTOR SHALL NOTIFY THE CONTRACTOR OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. TOGETHER, AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING 3. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL CONDUCTORS IN ACCORDANCE WITH THE NEC. APPLICABLE CODES, REGULATIONS, AND ORDINANCES. SUBCONTRACTOR SHALL ISSUE ALL 18.THE EXISTING CELL SITE IS IN FULL COMMERCIAL OPERATION. ANY CONSTRUCTION WORK BY P`G ow,,CENTERLINE SHALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND SUBCONTRACTOR SLL NOT DISRUPT THE EXISTING NORMAL OPERATION. ANY WORK ON 3. THE SUBCONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTIAL• RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81 STANDARDS) FOR LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. EXISTING EQUIPMENT MUST BE COORDINATED WITH CONTRACTOR. ALSO, WORK SHOULD BE NEW GROUND ELECTRODE SYSTEMS. THE SUBCONTRACTORDANDA S)FUFORISH ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY SCHEDULED FOR AN APPROPRIATE MAINTENANCE WINDOW USUALLY IN LOW TRAFFIC PERIODS 750 WEST CENTER AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE AFTER MIDNIGHT. WEST BRIDGEWA ER, MA 02379 REGULATIONS. 19.SINCE THE CELL SITE IS ACTIVE, ALL SAFETY PRECAUTIONS MUST BE TAKEN WHEN WORKING A TEST RESULT OF 5 OHMS OR LESS. 4. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED 4. NAYINGS PROVIDED HERE ARE NOT TO BE SCALED AND ARE INTENDED TO SHOW OUTLINE AROUND HIGH MOF ELECTROMAGNETICORKO RADIATION. EQUIPMENTWK SHOULD BE SHUTDOWN. ONLY, PRIOR TO PERFORMING ANY WORK THAT COULD EXPOSE THE WORKERS TO DANCER. EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH PERSONAL RF EXPOSURE MONITORS ARE ADVISED TO BE WORN TO ALERT OF ANY DANGEROUS g I] 17.1)1 �I_ ✓q GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE 5. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, EXPOSURE LEVELS. 1 FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON 20.APPLICABLE BUILDING CODES: THE DRAWINGS. 5. EACH BTS CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL {)I�T�"(Ir7T MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT 6. "KITTING LIST" SUPPUED WITH THE BID PACKAGE IDENTIFIES ITEMS THAT WILL BE SUPPUED BY CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. f GROUND WIRES, #6 AWG STRANDED COPPER OR LARGER FOR INDOOR BTS CONTRACTOR. ITEMS NOT INCLUDED IN THE BILL OF MATERIALS AND KITTING LIST SHALL BE THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OFOVER,M401815 ANDOVER AND #2 AWG STRANDED COPPER FOR OUTDOOR BTS. SUPPUED BY THE SUBCONTRACTOR. CONTRACT AWARD SHALL GOVERN THE DESIGN. El,I9)91 557-5553 58 ECHWOOp DRIVE,NORlH 090 6. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS 7. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH BUILDING CODE: IBC 2015 & MA STATE BUILDING CODE 780 CUR 9TH EDITION BELOW GRADE. MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. ELECTRICAL CODE: 2017 NATIONAL ELECTRICAL CODE (NEPA 70-2017) 7. APPROVED ANTIOXIDANT COATINGS (I.E., CONDUCTIVE GEL OR PASTE) 8. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE SUBCONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING 'Y'\' '-'1c, OF �4SSq SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. SUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION SPACE FOR APPROVAL BY STANDARDS: �,/ya`� c, THE CONTRACTOR. DANIEL P. GJ 8. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED AMERICAN CONCRETE INSTITUTE (ACI) 318; BUHJ)ING CODE REQi EMENTS FOR f / M OR BOLTED TO GROUND BAR. 9. SUBCONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT, POWER AND Ti CABLES, STRUCTURAL CONCRETE; I v --A GROUNDING CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN DRAWING. 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL SUBCONTRACTOR SHALL UTIUZE EXISTING TRAYS AND/OR SHALL ADD NEW TRAYS AS AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AIS,) MANUAL OF STEEL ` y NOT BE USED FOR GROUNDING CONNECTIONS. NECESSARY. SUBCONTRACTOR SHALL CONFIRM THE ACTUAL ROUTING WITH THE CONTRACTOR. CONSTRUCTION, ASD, FOURTEENTH EDITION; 0.417 0 10. MISCELLANEOUS ELECTRICAL AND NON-ELECTRICAL METAL BOXES, 10.THE SUBCONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, TELECOUIIUMCATTONS INDUSTRY ASSOCIATION (TiA) 222-H, , �O G�STE���F�� FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT STRUCTURAL STANDARDS FOR STEEL ACCORDANCE WITH THE NEC. SUBCONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. S/�NA�� 11. METAL CONDUIT SHALL BE MADE ELECTRICALLY CONTINUOUS WITH FOR ANY CONFUCTS BETWEEN SECTIONS OF USTED CODES AND STANDARDS REGARDING _41....i LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH 11.SUBCONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS MATERIAL, METHODS OF CONSTRUCTION, OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE 1 COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACIUTY. ANTENNAS REQUIREMENT SHALL GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT `CHECKED BY: AT I #6 AWG COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL GOVERN. I APPROVED BY: DPH 12. ALL NEW STRUCTURES WITH A FOUNDATION AND/OR FOOTING HAVING 20 12.SUBCONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. FT. OR MORE OF 1/2 IN. OR GREATER ELECTRICALLY CONDUCTIVE REINFORCING STEEL MUST HAVE IT BONDED TO THE GROUND RING USING AN 13.ALL CONCRETE REPAIR WORK SHALL BE DONE IN ACCORDANCE WITH AMERICAN CONCRETE SUBMITTALS EXOTHERMIC WELD CONNECTION USING #2 AWG SOLID BARE TINNED COPPER INSTITUTE (ACI) 301. GROUND WIRE, PER NEC 250.50ARV. NUE AMBITION B! 14.ANY NEW CONCRETE NEEDED FOR THE CONSTRUCTION SHALL BE AIR-ENTRAINED AND SHALL HAVE 4000 PSI STRENGTH AT 28 DAYS. ALL CONCRETE WORK SHALL BE DONE IN ACCORDANCE WITH ACI 318 CODE REQUIREMENTS. 15.ALL STRUCTURAL STEEL WORK SHALL BE DETAILED, FABRICATED AND ERECTED IN ACCORDANCE 1 11/10/22 SAM FOR CONS1RSTSN Js I 0 11/07/72 SHAD FOR REVFN Js A 10/11/22 MD FAR RENEW JS CLUSTER AND NODE NUMBER: CRAN_RCTB_MCAP E_1 1 3 SITE ID: ABBREVIATIONS CRAN_RCTB_MCAPE_1 1 3 SITE ADDRESS: AGL ABOVE GRADE LEVEL EQ EQUAL REQ REQUIRED 17 SEA GULL ROAD WEST YARMOUTH, MA 02673 AWG AMERICAN WIRE GAUGE GC GENERAL CONTRACTOR RF RADIO FREQUENCY BARNSTABLE COUNTY BBU BATTERY BACKUP UNIT GRC GALVANIZED RIGID CONDUIT TBD TO BE DETERMINED TITLE BTCW BARE TINNED SOLID MGB MASTER GROUND BAR TOR TO BE REMOVED COPPER WIRE GENERAL NOTES TO BE REMOVED AND BGR BURIED GROUND RING MIN MINIMUM TBRR REPLACED BTS BASE TRANSCEIVER STATION P PROPOSED TYP TYPICAL E EXISTING NTS NOT TO SCALE UG UNDER GROUND � J SSHHEETT NUMBER RADIATION CENTER LINE VIF VERIFY IN FIELD 1 -R I\I EGB EQUIPMENT GROUND BAR RAD (ANTENNA) `/I EGR EQUIPMENT GROUND RING REF REFERENCE