Loading...
HomeMy WebLinkAbout17 Raymond Ave plans 3(2) 2xl2 ridge 2x10 @ 16" o.c. 3 TAB ROOF SHINGLES (MATCH EXISTING) FRAMING NOTES: 15# ROOFING FELT PROVIDE DOUBLE JSTS. UNDER ALL WALLS RUNNING PARALLEL TO JOISTS. ''/2' CDX PLYWOOD j PROVIDE POSITIVE VENTILATION AT EA. END OF EA. RAFTER SPACE AT VAULTED CEILING AREAS. CLOSED CELL SPRAY FOAM PROVIDE FIRE BLOCKING, DRAFT STOPS AND FIRE STOPS AS PER I.B.C. SEC. /2" BLUEBOARD/PLASTER R502.12 PROVIDE POSITIVE CONECTIONS AT EACH END OF ALL POSTS AND COLUMNS TO RESIST LATERAL DISPLACEMENT. GENERAL NOTES: THE BUILDER SHALL VERIFY THAT SITE CONDITIONS ARE CONSISTENT WITH THESE PLANS BEFORE STARTING WORK. WORK NOT SPECIFICALLY DETAILED SHALL BE CONSTRUCTED TO THE SAME QUALITY AS SIMILAR WORK THAT IS Simpson H25A rafter clips each rafter DETAILED. ALL WORK SHALL BE DONE IN ACCORDANCE WITH INTERNATIONAL BUILDING CODES AND LOCAL CODES. WRITTEN DIMENSIONS AND SPECIFIC NOTES SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND GENERAL NOTES. THE ENGINEER/DESIGNER SHALL BE CONSULTED FOR CLARIFICATION IF SITE CONDITIONS ARE ENCOUNTERED THAT ARE DIFFERENT THAN SHOWN, IF DISCREPANCIES ARE FOUND IN THE PLANS OR NOTES, OR IF A QUESTION ARISES OVER THE INTENT OF THE PLANS OR NOTES. CONTRACTOR SHALL VERIFY AND IS RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING ROUGH OPENINGS). PLEASE SEE ADDITIONAL NOTES CALLED OUT ON OTHER SHEETS. v BUILDING PERFORMANCE: n�n`` HEAT LOSS CALCULATIONS SHALL COMPLY WITH THE REQUIREMENTS OF W REGIONALAND LOCAL CODES. SEE CALCULATIONS. PORCHES, DECKS, FOUNDATION, FIREPLACE ENCLOSURES, AND GARAGE AREAS NOT INCLUDED IN LIVING AREA. ALL EXHAUST FANS TO BE VENTED DIRECTLY TO THE EXTERIOR. ALL PENETRATIONS OF THE BUILDING ENVELOPE SHALL BE SEALED WITH CAULK OR FOAM. 4 SIDING (SEE ELEVATIONS) '/z CDX PLYWOOD Tr 2X4 @ 16" O.C. V R-21 FBGLS INSUL. 2-MIL. POLY VAPOR BARRIER 2 BOARDIPLASTER 1/2" PT PLYWOOD FASTENED TO PT 2X12 AT DECK SIDE OF ADDITION FOR 4 BOTTOM OF JOISTS DECK LEDGER ATTACHMENT c SIMPSON ABU46 POST BASE d ° e 5/8" ANCHOR BOLT a _ � a a ° 12" DIA. SONOTUBE a BEDROOM 5ECTION a a scale: 1" = 1' ° a Q a ° 4 28" BIGFOOT FOOTING Gross Section 1 C.A. Vincent, Inc. design 1 build �f wa a%n / Aow tl��y .. . know your dutl�t. 17 Still Brook Road South Yarmouth Massachusetts, 02664 ph:774-212-0938 info@cavincent.com WWW.CAVINCENT.COM Layout Pa qe Table Sheet # Title P-2 Plot Plan A-2 Proposed 1st Floor Plan A-3 Bedroom Section A-6 Foundation Plan E-1 Existing Elevations E-2 Proposed Elevations E-3 Bedroom 3 Elevations E-4 Bath Elevations m 2021 C. A. VINCENT, INC. THESE DRAWINGS AND ALL OF THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED HEREIN OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERTY OF C. A. VINCENT, INC. NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE EXCEPT WITH SPECIFIC WRITTEN PERMISSION OF THE FIRM C. A. VINCENT, INC. THESE PLANS ARE NOT TO BE USED FOR PERMITTING OR CONSTRUCTION PURPOSES UNLESS STAMPED AND SIGNED WITH AN ORIGINAL STRUCTURAL ENGINEER'S STAMP AND SIGNATURE AND MARKED AS "PERMIT SET" OR "CONSTRUCTION SET". Structural Engineer Stamp: CLIENT: FEAR 17 Raymond Avenue South Yarmouth, MA SCALE: 'J4" = 1' Tl 0 1 2 4 g UNLESS OTHERWISE NOTED. TITLE: Bedroom Section SHEET NO. A-3 THIS SHEET INVALID UNLESS ACCOMPANIED BY A COMPLETE SET OF WORKING DRAWINGS DATE: 6/28/22