HomeMy WebLinkAbout40 Mayflower Ter plan 5TimberStrand LSL RIM BOARD For information on lateral load capacities refer to current TimberStrand LSL rim board literature 1) LVL may also be used as rim board TYPICAL DETAIL 0 EXTERIOR WALLS Backer block: Install tight to top flange (tight to bottom flange with face mount hangers). Attach with 10-10d (3') box nails, clinched when possible. Filler block: Nail with 10-10d (3") box nails, clinched when possible. Use 10-1 6d (3 1 /2") box nails from each side with TJI Pro 550 joists. * With top flange hangers, backer block required only when hanger load exceeds 250 pounds TYPICAL DETAIL ® INTERSECTION OF DOUBLE MEMBERS Microllam LVL, Parallam PSL flange nger ce mount nger Web stiffeners are required if the sides of the hanger do not laterally support the TJI joist top flange and per current Trus Joist MacMillan literature TYPICAL DETAIL OF FLUSH FRAME AT MICROLLAM Load bearing or shear wall above (must stack over wall below) king panel Web stiffeners required each side at B1 W TYPICAL DETAIL ® LOAD BEARING WALLS TYPICAL LVL/GLULAM BOLTING/NAILING MULTI 1 3/4" BEAMS 2" 2 PIECES D-4" 2- 3 PIECES JE -4" LLI - 2 ROWS OF 16D NAILS 0 12" O.C. 2 ROWS OF 1/2" DIAM BOLTS 0 12" O.C. JO 0 OOz O' �LJJ X0 �O �o �LLJ V)_ ALL RAFTERS SHALL BE 2X10 ® 16" O.C. UNLESS NOTED OTHERWISE. NOTE: FRAMING PLANS ARE CONCEPTUAL. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT FINAL STRUCTURAL DESIGN AND CONSTRUCTION ADDRESS ALL LOADS AND IS IN COMPLIANCE WITH THE MASSACHUSETTS STATE BUILDING CODE. ANY DESCREPANCIES IN AND/OR DEVIATIONS FROM THESE DOGS. NOT BROUGHT TO THE ATTENTION OF THE ARCHITECT, BECOME THE SOLE RESPONSIBILITY OF THE CONTRACTOR. DEMOLITION NOTES: 1. CONTRACTOR SHALL VISIT THE SITE TO VERIFY AND BE FULLY AWARE OF EXISTING CONDITIONS PRIOR TO START OF WORK. CONTRACTOR SHALL IDENTIFY ALL EXISTING ITEMS OF WORK SCHEDULED TO REMAIN OR SALVAGED FOR REUSES. 2. ALL DEMOLITION WORK SHALL BE PERFORMED IN ACCORDANCE W/ STATE & LOCAL REGULATIONS. CONTRACTOR SHALL SECURE AND PAY FOR ALL REQUIRED DEMOLITION PERMITS. 3. COORDINATE ALL DEMOLITION OPERATIONS W/ OWNER FOR SHUTDOWN PERIODS & SEQUENCES OF WORK. ARRANGE W/ OWNER &/OR APPROPRIATE UTILITIES FOR SERVICE SHUTOFFS BEFORE BEGINNING DEMOLITION OPERATIONS. PROVIDE TEMPORARY DUST PARTITIONS, BARRICADES, AND PROTECTIVE ENCLOSURES TO PROPERLY SECURE, ISOLATE, AND WATERPROOF AREAS OF WORK AND EXISTING AREAS AND ELEMENTS TO REMAIN. THE CONTRACTOR 'SHALL PERFORM THE WORK OF THIS CONTRACT IN A MANNER THAT CAUSES NO DISRUPTION TO THE CONTINUOUS OCCUPATION, WHEN AND WHERE APPLICABLE, OF THE BUILDING & SITE FOR THEIR INTENDED PURPOSE. 4. REMOVE ALL DEMOLISHED MATERIALS IN ACCORDANCE WITH LOCAL REGULATIONS. 5. IT IS NOT THE INTENT TO SHOW EVERY PIECE OR ITEM TO BE REMOVED IN THE DEMOLITION WORK. PLUMBING, ELECTRICAL, AND OTHER WORK RELATED TO A WALL, OR OTHER AREA SCHEDULED FOR DEMOLITION AND REMOVAL, SHALL BE PERFORMED WHETHER NOTED OR NOT. 6. THE EXTENT OF ALL SPECIFIC DEMOLITION WORK SHALL BE COORDINATED W/ THE CONTRACT DOCUMENTS. 7. CONTRACTOR SHALL PATCH/REPAIR/REFINISH, AS REQUIRED, ALL SURFACES EXPOSED BY DEMOLITION WORK WITH MATERIALS & METHODS TO MATCH FINISH AND MAKE FLUSH W/ EXISTING ADJACENT SURFACES. WORK SHALL INCLUDE ALL LABOR & MATERIALS ON ALL SURFACES REQUIRED TO RENDER SUBSTRATES ACCEPTABLE TO RECEIVE NEW FINISHES SPECIFIED IN ACCORDANCE W/ MANUFACTURER'S SPECIFICATIONS. 8. CAP & REMOVE ALL ABANDONED ELECTRICAL, PLUMBING, MECHANICAL, AND FIRE PROTECTION ITEMS BACK TO SOURCE. 9• WHERE EXISTING FINISHES ARE INDICATED TO REMAIN AS BASE MATERIAL SURFACES FOR INSTALLATION OF NEW FINISH, REMOVE ALL PROJECTIONS AND VOIDS AND SECURE OR REMOVE AND REPLACE ANY EXISTING LOOSE OR OTHERWISE UNSUITABLE SUBSTRATE MATERIAL. TYPICAL NOTES: 1. THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR THE VERIFICATION OF THE CONDITION OF ANY EXISTING 'STRUCTURE, EQUIPMENT OR APPLIANCE AS PART OF BASIC SERVICES UNLESS IT IS PART OF ARCHITECT'S SCOPE STATED IN THE AGREEMENT AND VERIFICATION IS MADE ONLY BY VISUAL OBSERVATION. IF THE ARCHITECT'S DOCUMENTS REQUIRE CHANGES DUE TO CONDITIONS NOT VISUALLY OBSERVABLE AT THE TIME OF PREPARATION OF THESE DOCUMENTS, THE SERVICES WILL BE ADDITIONAL SERVICES. 2. STRUCTURAL ENGINEER OR ARCHITECT SHALL PERFORM FRAMING INSPECTION WHEN FRAMING IS COMPLETE AND PRIOR TO ENCLOSURE BY INTERIOR WALL PLASTER BOARD/FINISH. 3. CONTRACTOR SHALL SCHEDULE AND PROTECT FROM WEATHER ALL EXISTING HOUSE COMPONENTS AND INTERIORS DURING CONSTRUCTION AND CONSTRUCT TEMPORARY STRUCTURES/ENCLOSURES AS MAY BE NECESSARY TO INSURE SUCH PROTECTION. 4. CONTRACTOR SHALL SITE INSPECT ALL EXISTING VS. PROPOSED CONDITIONS PRIOR TO AND DURING CONSTRUCTION AND NOTIFY ARCHITECT OF ANY DESCREPANCIES AND/OR CHANGES THAT MAY BE ENCOUNTERED. 5. CONTRACTOR SHALL CONSTRUCT AND MAINTAIN TEMPORARY WALLS/ SHORING ETC. TO MAINTAIN/PROTECT EXISTING HOUSE AND STRUCTURAL INTEGRITY OF EXISTING HOUSE. 6. DRAWINGS CONVEY DESIGN INTENT. CONTRACTOR SHALL SITE INSPECT/VERIFY ALL EXISTING VS. PROPOSED CONDITIONS PRIOR TO AND DURING CONSTRUCTION AND MAKE ADJUSTMENTS AS NECESSARY, W/ ARCHITECT'S APPROVAL, TO ENSURE COMPLIANCE WITH DESIGN INTENT. 7. DASHED LINES INDICATED EXISTING CONDITIONS TO BE REMOVED/ALTERED. 8, THE CONTRACTOR IS RESPONSIBLE FOR THE PERFORMANCE OF THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND SHALL BE EXCLUSIVELY RESPONSIBLE FOR ITS CONSTRUCTION MEANS, METHODS, SEQUENCES, WARRANTIES, AND PROCEDURES, AND FOR CONSTRUCTION SAFETY. O SECOND FLOOR PLAN TYPICAL NOTES: ALL EXISTING DIMENSIONS ARE APPROXIMATE WHILE NO "AS —BUILT' DOCUMENTATION CAN BE COMPLETELY ACCURATE, THESE DRAWINGS HAVE BEEN PREPARED IN ACCORDANCE WITH ALL ACCEPTABLE PROFESSIONAL STANDARDS OF CARE. NO STRUCTURE OR STRUCTURAL SUPPORTS WERE OBSERVED OR RECORDED IN THESE DRAWINGS a r F h -LLI%'C t-s Lit: 60ei f t( SZ architects interior designers builders 299 WHITE'S PATH SOUTH YARMOUTH, MASSACHUSETTS, 02664 tel (508) 362 - 8883 (508) 760 - 2800 fax (508) 760 - 5800 WWW.ERTARCHITECTS.COM THE L E RESIDENCE i MAYFLOWER TERRACE SOUTH YAR MOAUTH I PROJECT # 410920 2020 ERT ARCHITECTS, INC. THE DRAWINGS AND ALL OF THE IDEAS, ARRANGEMENTS, DESIGNS, AND PLANS INDICATED THEREON OR REPRESENTED THEREBY, ARE OWNED BY AND REMAIN THE PROPERTY OF ERT ARCHITECTS, INC. NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE, EXCEPT WITH SPECIFIC WRITTEN PERMISSION OF THE FIRM ERT ARCHITECTS, INC. THESE PLANS ARE NOT TO BE USED FOR PERMITTING OR CONSTRUCTION PURPOSES UNLESS STAMPED & SIGNED WITH AN ORIGINAL ARCHITECT'S STAMP AND SIGNATURE & MARKED AS "PERMIT SET' OR "CONSTRUCTION SET'. I REGISTRATION REVISIONS DATE: REVISIONS: ISSUED FOR: DATE: PROJECT TRUE SCALE: 1 /4"=1'-O" 0 1 2 4 8 UNLESS OTHERWISE NOTED. SHEET NO. A * 1 TOTAL NUMBER OF SHEETS IN SET: 8 THIS SHEET INVALID UNLESS ACCOMPANIED BY A COMPLETE SET OF WORKING DRAWINGS