Loading...
HomeMy WebLinkAbout41 Jerusha septic planLEGEND 99 - EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[991- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 TEST HOLE 2% SLOPE OF GROUND C-Q-) UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING SYSTEM DESIGN: SYSTEMPROFILE ( Q SCALE) f- MARK CORNERS OF LEACHING = E-w 10V/ ACCESS COVERS TO WITHIN 6" OF FIN. GRADE { REBAR SET 4' BELOW INSPECTION PORT (SEE DETAIL) TOP FNDN. EL. 15.5' GRADE \ 11 2% SLOPE *THE INSTALLER SHALL VERIFY THE 14.0'1 MINIMUM .75' OF COVER OVER PRECAST FILTER FABRIC -- -C: ' LOCATIONS OF ALL UTILITIES AND ALL PRECAST H-10 RISERS (TYP.) WATERTEST O BOX ` 13 5' .7,8' =iN!SHED GRADE- 4" , ' LOAM & SEED OR PAVE AS REQ. BUILDING SEWER OUTLETS AND 2'0 FOR LEVELNESS 4"OSCH40 PVC ELEVATIONS PRIOR TO INSTALLING ANY PIPES LEVEL 1ST 2' PORTION OF SEPTIC SYSTEM a� *12.25't 10° 1500 GAL H-10 14" 12.05' TEE SEPTIC TANK TEE 4" P�`� �' o.C. S=O.D05I 0 ' SLAB EL. 7.5'f GAS BAFFLE,:: 3/4"-1-'/2" DOUBLE 'WASHED ° ° �: 4' LIQ. LEVEL {ACME OR EQUAL),; 11.7' 11.53' 8" STONE LEACHINGFIELD ° 6"DEPTH MIN BELOW INV. 47 11.45 LEVEL BOTTOM 0 11.3 DUE TO HIGH GROUNDWATER •°paQ°Q°9°°°�°�°�°;°;°0°0°�°�°O°O°O°Q°ODO °°°°°°'°°°°°°°°• , CONDITIONS A FOUNDATION DRAIN IS RECOMMENDED. 6" CRUSHED STONE OR MECHANICAL 30 0" COMPACTION. (15.221 [21) 10. a' ( % SLOPE) MIN. (--!-X SLOPE) ( 1 %SLOPE) FOUNDATION- 10' SEPTIC TANK 10' D' BOX 10' LEACHING FACILITY GARBAGE DISPOSER IS NOT ALLOWED EXISTING 3 BR DWELLING PROPOSED 3 BR DWELLING DESIGN FLOW: 3 BEDROOMS ® 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. H-10 SEPTIC TANK LEACHING: 330 GPD (.74) = 446 SF REQUIRED 15' X 30' = 450 SF OK 450 SF X .74 = 333 GPD OK USE A 15' X 30' PIPE AND STONE LEACHING FIELD BICE ##21-298 ADJ. G.W. EL.= 5.8' REMOVE EXISTING DRIVEWAY wx 11 A E D L JER US A S84,193 Ili L�j X ON O _DRIVE 2 [11 21 t PROPOSED STONE TAININ W� o Tnp WAI I P 1 5' 1� ¢LL x 12 13 , nJ LOT 52 16,133 S.F. PORCH [ 13.5] . . PROP()"S'Ep y 1 Q D ,NG TOP 15.5' .> =I GARAGE SLAB PROP D 50' r I w .. � DRIVE :. E AY 5 CIO k v / r cv HED 0 tis ,f �� TH1 D co �. SHED �^ APPROXIMATE SEPTIC SHED X o U 0 V k BENCHMARK: \�� \ 5' REMOVAL OF UNSUITABLEH YD. TAG BOLT SOIL REQUIRED Y =15.2 NAVD88 AROUND PERIMETER OF LEACHING FACILITY, -7 DOWN TO SUITABLE SOIL LAYER. REPLACE O WITH CLEAN MED. SAND TO MEET SPECIFICATIONS OF 310 CMR 15.255(3) O o O O O r If ) E VARIANCE REQUESTED: UNDER TOWN OF YARMOUTH HEALTH REGULATIONS: REDUCTION IN GROUNDWATER ADJUSTMENT: USE 1.0' OF THE OCTOBER '21 2.0' ADJUSTMENT NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM P!PE PITCH TO BE 1/8` PER FOOT. 4. DESIGN LCADING FOR ALL PROPOSED PRECAST UNITS TO BE AASI-C H-M 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCUS MAP LOCATION OF ALL UNDERGROUND do OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. SCALE 1 "=2000't 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE ASSESSORS MAP 31 PARCEL 207 REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE X 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND (AREA OF MINIMAL FLOOD HAZARD) AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. ZONE AE (EL. 11) AS SHOWN ON COMMUNITY PANEL ##25001 C0588J DATED 7/16/2014 UNSUITABLE SOIL ZONING SUMMARY ZONING DISTRICT: R-25 DISTRICT EXISTING PROPOSED MIN. LOT SIZE 25,000 S.F. 16,133 S.F. 16,133 S.F MIN. LOT FRONTAGE 150' 129.74' 129.74' MIN. FRONT SETBACK 30' 39.0' 30.5' MIN. SIDE SETBACK 15' 15.5' 15.4' MIN. REAR SETBACK 20' - - MAX. BUILDING COVERAGE 25% 9.4% 16.1% MAX. BUILDING HEIGHT 35' - 22'f TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE # 13871 WITNESS: PHIL RENAUD DATE: 10/21 /21 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. ELEV. 0" 12.3' 0" 12.5' A A /LS BLS 1OYR 3/2 10YR 3/2 18° 12» / B B �LS BLS „ 1OYR 6/8 36 ;//ii 9.3 30" 10YR 6/8 / / / 10.0' PERC C C MS MS 2.5Y 7/4 2.5Y 7/4 GROUNDWATER ADJ. DATA: WELL: MIW 29 ZONE: B ADJUSTMENT: 2.0' (OCTOBER) 108" 1 1 3.3' 108" 3.5' GROUNDWATER ENCOUNTERED AT 90" EL. 4.8' PREPARED FOR DOREEN MCNEILL Zz- z L L DATE: DECEMBER 7, 2021 �0NOFMASS �yZHOFMIN DATE: APRIL 22, 2022 (SEPTIC PROFILE) � DANIELA. G o�� DAN.IEL q�yG �, ,� �, DATE: 6-22-22 (HOUSE CHANGES) o OJALA CIVIL n A. E OJALA w No. 46502 No. 40980 Ir Scale: 1 "= 20' H o 91STe'OF s 0 j�ss� � a� 'AL EN °f DANIELA. DANIEL - URV`I(a o A. 0 10 20 30 40 50 FEET OJALA CIVIL CJAtA No. 409i30 off 508-362-4541 No.46502 c -; _ �oP '� fax 508-362-9880 ESS\o`a Rdown downcape.com Qh A �G - cope en sneer n ine. � �! civil engineers land surveyors DATE DANIEL A. OJALA, P.E., P.L.S. 939 Main Street Rte 6A � ) YARMOUTHPORT MA 02675 " LI LJtJ IVI IiIV L I LL. U YVV