HomeMy WebLinkAbout8 Danbury site planJ DCE #09-293
P
'THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL
UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS
PRIOR TO .INSTALLING ANY PORTION OF SEPTIC SYSTEM
O
S log iio
9,500± s
1
'9
Uj
o U) o ; ,0
o EXISTING
Q o DWELLINGcc 0
27.6' a ¢ 1 TOF = 10.5
30.1 '
REROUTE s Q
01 EXISTING �`� 0 ti
SEPTIC S a'
FORCE
MAIN ,------, 0
1
a
100.00'
ANBUR
n
Scale: 1 "- 20'
0 10 20 30 40 50 FEET
rc�
NOTES
1. DATUM IS NAVD88
2. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO
BE USED FOR LOT LINE STAKING OR ANY OTHER
PURPOSE.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING
DIGSAFE (1-888-344-7233) AND VERIFYING THE
LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES
PRIOR TO COMMENCEMENT OF WORK.
4. EXISTING SEPTIC LOCATION PER TIE —CARD ON FILE
WITH TOWN.
5. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH
310 CMR 15.000 (TITLE 5.)
6. SEPTIC WORK DONE SHALL BE PERFORMED BY
LICENSED SEPTIC INSTALLER_
7. OWNER'S ENGINEER TO PERFORM INSPECTIONS OF THE
FINAL INSTALLATION. MINIMUM OF 24 HOURS NOTICE
REQUIRED.
LOCUS MAP
SCALE 1 "=2000't
ASSESSORS MAP .34 PARCEL 168
LOCUS IS WITHIN FEMA FLOOD ZONE AE (EL. 11)
AS SHOWN ON COMMUNITY PANEL #25001CO583J
DATED 7/116/2014
ZONING SUMMARY
ZONING DISTRICT: R-25 DISTRICT
REQUIRED:
EXISTING:
PROPOSED:
MIN.
LOT SIZE
25,000 S.F.
9,500 S.F.
9,500 S;F.
MIN.
LOT FRONTAGE
150'
100'
100'
MIN.
FRONT SETBACK
30'
31.9'
31.9
MIN.
SIDE SETBACK
15'
30.1'
26.9'
MIN.
REAR SETBACK
20'
19.8'
21.3'
MAX.
BUILDING COVERAGE
25%
11.2%
14.6%
MAX.
BUILDING HEIGHT
35'
SITE PLAN
OF
` BURY STREET
OFMsHOFMS��SMMA
���,
DANIELA. tiG o`er DANIEL �G
0 OJALA o A. �� PREPARED FOR
CIVIL t" OJALA U)
o No.46502 No.40980 EDWIN LEARY
P
�ISTER�O��
DATE: APRIL 6, 2022
off 508-362-4541
fax 508-362-9880
downcope.com
down csAe engiatefinbr, ioc.
civil engineers
land surveyors
939 Main Street ( R to 6A)
YARMOUTHPORT MA 02675
09-293 LEARY 2022_DWG
N�H OF Ugs�9c� •
DANIELA. �N
o OJALA
CIVIL
No.46502
Li'�-7-1
DATE
DANIEL
A. �ma
OJALA
No.40980
DANIEL A. OJALA, P.E., P.L.S.