Loading...
HomeMy WebLinkAbout24 Charles St plan 7TYPICAL WALL NOTES PROVIDE MEMBRANE BEHIND SPACER CARRY 18" UP WAII SPACER 3/4" DECKING 2X8 PT LEDGER FASTENED TO EXISTING BOX W/ 3 5/8" LEDGERLOK SCREWS ® 8 O.C. STAGGERED TOP & BOTTOM W/ 2 ® ALL ENDS SIMPSON LUS28SS HANGER A 2X8 PT ® 12" O.C. FOUNDATION DESIGN & SILL DETAIL BY OTHERS - SILL DETAIL 0 DECK 1 SCALE 1-1/2" = V-0" POST 3®2X8 PT (ONLY 2 SHOWN) THREADED ROD TUBE OR FOOTII SONO TUBE OR FOOTING 166 SE 6X6 PT POST TYPICAL EXT. POST BASE 9 NOT TO SCALE FRAMING NOTES: 1. ALL FRAMING LUMBER SHALL BE HEM —FIR GRADE NO. 2 OR S.P.F. (SPRUCE — PINE — FIR) GRADE NO. 1 AND 2 OR APPROVED EQUAL (UNLESS OTHERWISE SPECIFIED) AND SHALL MEET THE REQUIREMENTS OF THE AMERICAN FOREST AND PAPER ASSOCIATION. THE MINIMUM ALLOWABLE BENDING STRESS (Fb) SHALL BE 1050 P.S.I. THE MINIMUM ALLOWABLE COMPRESSION STRESS (Fc) SHALL BE 400 P.S.I. THE MINIMUM ALLOWABLE MODULUS OF ELASTICITY (E) SHA-L BE 1,400,000 P.S.I. 2. ALL LVL'S TO BE BOISE CASCADE OR I — LEVEL WEYERHAUSER VERSA — LAM 3100FB OR APPROVED EQUAL. THE MINIMUM ALLOWABLE BENDING STRESS (Fb) SHALL BE 3100 P.S.I. ALL LVL POSTS TO BE VERSALAM 1.7 2650 FB, 1.8E PARALLAM PSL OR APPROVED EQUAL.NISTALL LVL'S IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 3. USE 3/4" TONGUE AND GROOVE STRUCTURAL GRADE FIR PLYWOOD FLOOR SHEATHING, 5/8" EXTERIOR STRUCTURAL GRADE FIR (C.D.X.) PLYWOOD ROOF SHEATHING, AND 1/2" EXTERIOR STRUCTURAL GRADE FIR (C.D.X.) AT WALLS. ALL JOINTS SHALL BE BLOCKED WITH LUMBER OR OTHER APPROVED SUPPORTS. 4. PROVIDE SOLID BLOCKING BETWEEN FLOOR JOISTS AND/OR DOUBLE ALL JOISTS UNDER EACH PARTITION. 5. USE FULLY NAILED METAL CONNECTORS (TECO, SIMPSON, OR EQUAL), JOIST, OR BEAM HANGERS WHEN JOISTS OR BEAMS FRAME INTO OTHER JOISTS OR BEAMS. PROVIDE METAL POST CAPS AND BASES FOR ALL POSTS. 6. FOR LVL BEAMS OR HEADERS PROVIDE SOLID 4X4 LVL MINIMUM POST SUPPORTS FOR DOUBLES AND SOLID 4X6 OR 6X6 LVL MINIMUM POSTS FOR TRIPLE BEAMS OR HEADERS, OR AS OTHERWISE SPECIFIED ON THE PLAN. 7. ALL PLYWOOD FLOOR SHEATHING SHALL BE GLUED TO SUPPORTING WOOD FRAMING MEMBERS USING AMERICAN PLYWOOD ASSOCIATION (A.P.A.) GLUED FLOOR SYSTEM. WOOD GLUE TO BE CONTECH, INC. PL400 SUBFLOOR CONSTRUCTION ADHESIVE, OR APPROVED EQUAL. 8. BUILT—UP BEAMS (3 PLY MAXIMUM) USING CONVENTIONAL FRAMING LUMBER SHALL BE FULLY SPIKED TOGETHER WITH 2-10D NAILS AT 12" O.C. LVL BEAMS (4 PLY MAXIMUM) TO BE THRU—BOLTED WITH 1 /'2 INCH DIAMETER THRU—BOLTS OR EQUIVALENT POWER SCREWS STAGGERED TOP AND BOTTOM AT 16 " O.C. OR AS OTHERWISE REQUIRED BY THE MANUFACTURER. 9. ALL MANUFACTURERED FLOOR I —JOISTS TO BE DESIGNED BY THE SUPPLIER/MANUFACTURER. SUBMIT SHOP DRAWINGS AND CALCULATIONS TO THE ENGINEER PRIOR TO FABRICATION. 8 TYPICAL EXT. POST CAP NIOT TO SCALE TYPICAL DETAIL ® EXTERIOR WALLS TimberStrand LSL RIM BOARD For information on lateral load capacities refer to current TimberStrand LSL rim board literature 13/4" Wicrollom LVL may also be used as rim board TYPICAL DETAIL ® INTERSECTION OF DOUBLE MEMBERS Backer block: Install tight to top flange (tight to bottom flange with face mount hangers). Attach with 10-10d (3') box nails, clinched when possible. Filler block: Nail with 10-10d (3") box nails, clinched when possible. Use 10-16d (3 1/'2") box nails from each side with TJI Pro 550 Joists. * With top flange hangers, backer block required only when hanger load exceeds 2.50 pounds LEDGERLOK SCREWS /® 8"v 0 C. STAGGERED TOP & BOTTOM W/ 2 ® ALL ENDS FIRST FLOOR & DECK FRAMING NEW FLOOR FRAMING SHALL BE 7.25" ENGINEERED FLOOR JOISTS ® 16'' O.C. UNLESS NOTED OTHERWISE NEW DECK FRAMING SHALL BE 2X10 PT ® 12" O.C. UNLESS NOTED OTHERWISE NOTE: FRAMING PLANS ARE CONCEPTUAL. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT FINAL STRUCTURAL DESIGN AND CONSTRUCTION ADDRESS ALL LOADS AND IS IN COMPLIANCE WITH THE MASSACHUSETTS STATE BUILDING CODE. ANY DESCREPANCIES IN AND/OR DEVIATIONS FROM THESE DOCS. NOT BROUGHT TO THE ATTENTION OF THE ARCHITECT, BECOME THE SOLE RESPONSIBILITY OF THE CONTRACTOR. TYPICAL DETAIL OF FLUSH FRAME AT MICROLLAM Microllam LVL, Parallam PSL -- T - - �d LSL p flange nger ce mount Inger Web stiffeners are required if the sides of the hanger do not laterally support the TJI joist top flange and per current Trus Joist MacMillan literature TYPICAL DETAIL ® LOAD BEARING WALLS Load bearing or shear wall above (must stack over wall below) <ing panel Web stiffeners required each side at 131 W TYPICAL LVL/GLULAM BOLTING/NAILING MULTI 1 3/4" BEAMS 2" 2 PIECES D-4" 2 ROWS OF 16D NAILS ® 12" O.C. 2" 3 PIECES D-4" 2 ROWS OF 1/2" DAM BOLTS ® 12" O.C. 2" a r c hL"�VC t s fit'A`(Itlleff4(�,�s le?",( architects interior designers builders 299 WHITE'S PATH SOUTH YARMOUTH, MASSACHUSETTS, 02664 tel (508) 362 - 8883 (508) 760 - 2800 fax (508) 760 - 5800 WWW.ERTARCHITECTS.COM M ACI SAAC RESIDENCE 24 CH AR LES STREET SOUTH YARMMOUTH, PROJECT # 080122 2022 ERT ARCHITECTS, INC. THE DRAWINGS AND ALL OF THE IDEAS, ARRANGEMENTS, DESIGNS, AND PLANS INDICATED THEREON OR REPRESENTED THEREBY, ARE OWNED BY AND REMAIN THE PROPERTY OF ERT ARCHITECTS, INC. NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE, EXCEPT WITH SPECIFIC WRITTEN PERMISSION OF THE FIRM ERT ARCHITECTS, INC. THESE PLANS ARE NOT TO BE USED FOR PERMITTING OR CONSTRUCTION PURPOSES UNLESS STAMPED & SIGNED WITH AN ORIGINAL ARCHITECT'S STAMP AND SIGNATURE & MARKED AS "PERMIT SET' OR "CONSTRUCTION SET". REGISTRATION REVISIONS DATE: REVISIONS: ISSUED FOR: PERMITTING DATE: 03.01.2022 b 1 A-5 PROJECT TRUE SCALE: 1 /4"=V-O" 0 1 2 4 8 UNLESS OTHERWISE NOTED SHEET NO. S.1 TOTAL NUMBER OF SHEETS IN SET: 11 THIS SHEET INVALID UNLESS ACCOMPANIED BY A COMPLETE SET OF WORKING DRAWINGS ■