Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLDE-22-007397
Commonwealth of Official Use Only . ,f. Massachusetts Permit No. BLDE-22-007397 **--' BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:6/24/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 9 Vernon St Owner or Tenant MICHELLE GRAVELINE/GRAVELINE TRUST Telephone No. Owner's Address 9 VERNON ST,WEST YARMOUTH, MA 02673 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(22 Panels) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiatine Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alertine Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal ❑ Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Siens No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: EDWARD L MERRY Licensee: Edward L Merry Signature LIC.NO.: 17137 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 15 CHECKERBERRY LN,W YARMOUTH MA 026733636 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 cL RECEIVED i,�om#row�rrwA>tt e�Ir/wMarc�+�+ official(;se Onl+� t 2 Permit No. 22sc only 4 t if t - ---- Occupancy and bee Checked BUILD( ' R_TM� j� D OF FIRE PREVENTION REGULATIONS [Rev, I AV] thav,blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to he performed in accordance with the Massachusetts Electrical Code NEC),527 C MR 12,00 (PLEASE PRINT IN INK OR TYPE ALL LVF"ORMATIo ) Date: March 3, 2022 City or Town of: West Yarmouth To the Inspector of il'ires.: By this application the undersigned gives notice of his or her intention to perform the electrical work described belo+v. Location(Street& Number)9 Vernon St. Owner or Tenant Michelle Graveline Telephone No. 508-237-4486 Owner's Address same as above is this permit in conjunction with a building permit? Yes X❑ No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service 200 Amps 120 / 240 Volts Overhead Q Undgrd 0 No.of Meters 1 New Service Amps l Volts Overhead❑ Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Install roof-mounted solar PV system consisting of 22 panels with 22 microinverters. Meter socket on exterior wall for utility company and commissioning solar system. C'oatpletitna n/the/rdhmin )able tear he waited ht'the ln't/,e i for eel litres No.of Recessed Luminaires No.of C'eii.-Susp.(Paddle)Fans 'l' of T KVrot A of k�'A No.of Luminaire Outlets No.of Hot Tubs Generators K A Above In- "No.of Emergency Lighting No.of Luminaires Swimming Pool grnd. grnd. ❑ Battery l nits No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones Na.of Switches No.of Gas Burners -No.ofDetectioti Initiating Devices No.of Ranges No.of Air Cond. Tatai No.of Alerting Devices g Tons Heat Pump Number Tons kW No.of Self-Contained - f No.of Waste Disposers Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal Connection /--1 other No.of Dryers Heating Appliances KW Security Ssstcros: No.of bevices or Equivalent No.of Water No.of No.of Data Wiring: KW Signs No.of Devices or Equivalent Heaters Ballasts a Bathtubs No.of Motors Total HP Telecommunications��inn r: No.Hydromassage No.of Devices or Equivalent OTHER: Attach additi.naI detail it desi,ed.or a,) requited))) the lns/hrtor../tt tees Estimated Value of Electrical Work: $1.500 (When required by municipal policy.I Work to Start:? -p?a2 Inspections to he requested in accordance with ME(' Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office, CHECK ONE: INSURANCE ❑X BON)) 0 OTHER 0 (Specify:) 1 c'ertif i'.under the pains and penalties of perjury,that the information on this application is true and complete. FiRM NAME: Ed Merry Master Electrician LiC.NO.: A17137 Licensee: Ed Merry Signature C / / `' LIC. NO.: 35745E U/tapplica/4e.rtucr "eAe'ntpt''its lilt'license tttrtnhc'r line•.) 7 Bus.Tel.No.: 508-221-4335 Address: 15 Checkerberry Lane,West Yarmouth,MA 02673 Alt.Tel.No.: *Per NI,(i:.L.c. 147.s. 5 -61,security work requires Department of Public Safety"S"License: Lic. No. OWNER'S INSURANCE WAI•'ER: I am aware that the Licensee does no!have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)0 owner 0 owner's agent. Owner/Agent Signature Telephone No. I PERMIT FEE: $ March 7, 2022 Graveline-Stout Residence SUNWINDLLC 9 Vernon Street Yarmouth, MA 02673 µa*`Knowledge is ZinlimitedTower'I' Roof Mount Array: (22)435 Watt LG Solar Panels=9.57 kW DC 7.67 kW AC String# 1 with 11 Enphase IQ-7A micro J ej\ 1 IQ-7A IQ-7A inverters inverters String#2 with 11 Enphase (11) (11) IQ-7A micro inverters ♦ ♦ #10 THWN Array# 1 Array#2 in conduit (11)435watt (l1)435watt Panels Panels #6 Ground Voc=39.2V Voc=39.2V wire Vmpp=31.8V Vmpp=31.8V Isc=9.80A isc=9.80A 1mpp=9.19A Impp=9.19A ,__�, #6 THWN in PVC Solar conduit combiner panel in r basement 60A0 (2)20A AC Disconnect 2 pole on exterior wall breakers Accessible 24/7 Customer Production Meter on exterior wall 200A Main Panel 6/3 Romex 6 THWN in conduit Drawn By: Timothy Holmes 0 SunWind,LLC 40 A Drawn: 3-4-2022 Breaker Eversource Meter „:„.,..:. ,.,. ..„...„, ,,,....,„:„4...„.„..„...„.. ON® . LG N ON R ,. ,, „....„. „:„..„,_ .„ ,„,„. .. LG435QAC-A6 Preliminary 435W LG NeON®R is powerful solar module that provides world-class performance.A new cell structure that eliminates electrodes on ` �'” ` - _.� the front maximizes the utilization of light and enhances reliability. _ - - - - LG NeON®R is a result of LG's efforts to increase customer's _ values beyond efficiency.LG NeON®R features enhanced durability, performance under real-world conditions,an enhanced warranty and aesthetic design suitable for C � US roofs. • DVE cc f � wus sos¢e+»sano�u,vr ti` -„1 ,,,,_., rit 21 „... ,,.., ...,, ,._. , ., Features tAir` Roof Aesthetics 25 Year Limited Product Warranty LG NeON®R has been designed with The NeON®R is covered by a 25-year limited aesthetics in mind:the lack of any product warranty.In addition,up to$450 of electrodes on the front creates an labor costs will be covered in the rare case that improved,modern aesthetic. a module needs to be repaired or replaced. Enhanced Performance Warranty More generation per square meter The LG NeON®R has an enhanced it The LG NeON®R has been designed to performance warranty.After 25 years, significantly enhance its output,making LG NeON®R is guaranteed at least it efficient even in limited space. 92.5%of initial performance. When you go solar, ask for the brand you can trust: LG Solar About LG Electronics USA,Inc. �� LG Electronics is a global leader in electronic products in the clean energy markets by offering solar PV panels and energy storage systems.The company first embarked on a solar 0 energy source research program in 1985,supported by LG Group's vast experience in the semi-conductor,LCD,chemistry and materials industries_In 2010,LG Solar successfully released its first MonoX°series to the market,which is now available in 32 countries.The NeON°(previous MonoX°NeON),NeON°2,NeON°2 Bifacial won the"intersolar AWARD"in 2013,2015 and 2016,which demonstrates LG's leadership and innovation in the solar industry. Life s Good .... ' LG NeON'R Preliminary LG43SQAC-A6 General Data Electrical Properties(STC*) . . Cell Properties(Material/Type) Monocrystaltine/N-type Model '. LG435QAC.A6 .. r Cell Maker LG Maximum Power(Pmax) [WI ! 435 CeU Configuration 66 Cells(6 x 11) NIPP Voltage(Vmpp) [V) ' 41.1 Module Dimensions(L x W x H) 1,910mm x 1,042rnm x 40mm MPP Current(Impp) [A] :, 10.59 Weight 20.5 kg Open Circuit Voltage(Voc,t 6%) .. M 48.0 Glass(Material) Tempered Glass with AR Coating Short Circuit Current(Ism-5%) [A] 11.20 Badslwet(Color) . White Module Efficiency [%] 21.9 Frame(Material) Anodized Aluminium Power Tolerance [%,] ' 0-.3 Junction Box(Protection Degree) IP 68 with 3 Bypass Diodes *STC(Standard Test Condition):Irradiance 1000 W/m1,Cell temperature 25•C,AM 1.5 Measure Tolerance:±3% Cables(Length) 1,250mm x 2EA Connector(Type/Maker) MC 4/MC Operating Conditions Operating Temperature [°C] : -40-+85 Certifications and Warranty Maximum System Voltage [V] 1,000 : IEC 61215-1/-1-1/2:2016,18C 61730-1/2:2016. Maximum Series Fuse Rating [A] : 20 UL 61730-1:2017,UL 61730-2:2017 Certifications** : GO 9001,I50 14001,ISO 50001 Mechanical Test Load**(Front) [Pa/psf] ' 5,400 OHSAS 18001 Mechanical Test Load"(Rear) [Pa/psf] . 4,000 Salt Mist Corrosion Test IEC 61701 2011 Severity 6 *The operating ambient temperature of these devices may exceed 40°C at full load for all wire sues if is determined : suitable in the fietd use application. ' Ammonia Corrosion Test IEC 62716 2013 **Based on IEC 61215-2 2016(Test Load-Design Load x Safety Factor(1.5)) Hail Test 25mm(1")diameter at 23m/s(52mph) Module Fire Performance Type 1(UL 61730) Packaging Configuration Fire Rating . Class C(UL 790,ULC/ORD C 1703) Number of Modules per Pallet. . [EA] 25 . _...__ . .....„.. . . .„..„.....„...... ........_____ .._._ ,____...........„ _ _____................... „ ...„...................„..___ . . Solar Module Product Warranty 25 Years Number of Modules per 40'Container [EA] 600 __ Solar Module Output Warranty Linear Warranty* Number of Modules per ST Container [EA] TBD *Improved:1.year 98.5%,from 2-24th year:-0.25%/year down,92.5%at year 25 Packaging Box Dimensions(L x W x H) [mm] 1,960 x 1,120 x 1,221 *tin Progress Packaging Box Dimensions(L a W x H) [in] 77.2 x 44.1 x48.1 Temperature Characteristics Packaging Box Gross Weight [kg] 549 NWT' ['C] 44 t 3 Packaging Box Gross Weight [lb] 1,210 Pmax [%/*C] -0.29 Voc [%/*C] -0.24 Dimensions(mm/inch) isc [WC] 0.04 %MOT(Nominal Module Operating Temperature):Irradiance 800 W/mr,Ambient temperature 20°C, Wind speed 1 m/s,Spectrum AM 1.5 1042.0/410(Size of Short Side) Electrical Properties(NMOT) _ 175.0/6.9 Model LG43SQAC-A6 .11-10. ............,............._...............................„... ..„._........_..........................._........................................„................. 1002.0/39.4(Di leo,between Holes) 40.0/1.57 Maximum Power(Amax) 1 [W] 330 a . .. 4 "- 16-8.0x3.0/0.3x0.1 ' L MPP Volt494(MIPP) I i i [V] 38.8 Drain Holes PM MPP Current(Impp) 1 [A] 649 8-04.3/02 / (•) ' f'1') , Open Circuit Voltage(Voc) m 45.8 Grotmliog Holes - 4-8.5x17.0/0.3 x0.5 Short Circuit Current(1st) I [A] 9.02 Mounting Holes -L 1250.0/49.2 1 I-V Curves Cable Udigth .? t -8' 3 ta 12.0 F 2 I 1000W 1 2 10.0 800W 1 g' . , 6.0 - ci 600W I I .3 6.0 . Zi I400W ,,, .• 200W ,-, q • . so 5.0 ,al) 15.0 20.0 25.0 :30.0 35.0 40.0 45 0 voltage fvj 0 LG Electronics USA,Inc. Product specifications are subject to change without notice. LG Solar Business Division 2000 Millbrook Drive 60069 LG435QAC-A6.pdf Lincolnshire,IL 121020 Life's Good www.lg-solarcom ©2020 LG Electronics USA,Inc.All rights reserved. a ' .h e Il ir' rnveq terss The high-powered smart grid-ready Enphase Enphase IQ 7A Micro" dramatically simplifies the IQ 7A M i c ro i nve rte r installation process while achieving the highest system efficiency for systems with 60-cell and 72-cell modules. Part of the Enphase IQ System,the IQ 7A Micro integrates with the Enphase IQ Envoy", Enphase IQ Battery",and the Enphase Enlighten" monitoring and analysis software. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. High Power • Peak output power 366 VA @ 240 VAC and 295 VA @ 208 VAC Easy to Install 1111 • Lightweight and simple • Faster installation with improved,lighter two-wire cabling • Built-in rapid shutdown compliant(NEC 2014&2017) Efficient and Reliable • Optimized for high powered 60-cell and 72-cell modules • Highest CEC efficiency of 97% • More than a million hours of testing Id • Class II double-insulated enclosure IQ7A • UL listed Smart Grid Ready OS IN • Complies with advanced grid support,voltage and frequency ride- through requirements • Envoy and Internet connection required • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) 0 EN PHASE Ea To learn more about Enphase offerings,visit enphase.com 9' Enphase IQ 7A Microinverter INPUT(DC) IQ7A-72-2-US Commonly used module pairings' 295 W-460 W+ Module compatibility 60-cell,66-cell,and 72-cell PV modules Maximum input DC voltage 58 V Power point tracking voltage range2 18 V-58 V Min/Max start voltage 33 V/58 V Max DC short circuit current(module Isc)3 15 A Overvoltage class DC port II DC port backfeed current 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT(AC) @ 240 VAC. _ w @ 208 VAC _ ..�.....�R.w .-.,w_...Peak output power 366 VA 295 VA Maximum continuous output power 349 VA 290 VA Nominal(L-L)voltage/range4 240 V/211-264 V 208 V/183-229 V VAC A Maximum continuous output current 1.45 A(240 VAC) 1.39 (208 ) Nominal frequency 60 Hz Extended frequency range 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms Maximum units per 20 A(L-L)branch circuits 11 (240 VAC) 11 (208 VAC) Overvoltage class AC port III AC port backfeed current 18 mA Power factor setting 1.0 Power factor(adjustable) 0.85 leading... 0.85 lagging EFFICIENCY @240 VAC @208 VAC CEC weighted efficiency 97.0% 96.5% MECHANICAL m " Ambient temperature range -40°C to+60°C Relative humidity range 4%to 100%(condensing) Connector type:DC(IQ7A-72-2-US) MC4 Dimensions(HxWxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2.CEC peak power tracking voltage range is 38 V to 43 V. 3.Maximum continuous input DC current is 10.2A. 4.Voltage range can be extended beyond nominal if required by the utility. 5.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com ©2020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7A,Enphase IQ Battery,Enphase Enlighten,Enphase IQ E A(�I(PHASE h Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change. 2020-06-16