Loading...
HomeMy WebLinkAboutBLD-23-002583 ----------] w NOV 0 8 2022 i NG DEPARTMENT d i J ---- - ..♦ f:.. ..! Sil6 i'. - * . tii' "(FP . V ., . I -ur. , '`(k'''02A54 ��`LICATION FOR FIRE PRO TEC7`IO PERMIT pp t I/g PEMT Is.M4lii,ER P)Ltd-2-5- 0(.)a 5\ PojtO staff h II/C1 c Dateof issue In, cozx ce wit the r provisions of 780 C and M GLL. C. ..cr 148,as ., 4vided in e So This ration is; e made by . F1 '- cY4 7 E✓j'!S /sv(✓ (Fulincong,afperson,-Firm orCorpor ee) mAresg r 4 5-' teed led . Da r Wv7 /t'1f� (Cot } 7D 4g1 �qt6 Email Jf*i/ Fr re s yt*ms ;4,fie-es O . £vL..i-serrrr6, .t Lo r m aL,f" J 1 f1'I w�/low set Y (Street&City or Town) For .ikon to(state 1y purpose for i.ci,.permit it is t f 'C r ct e I.e v ei'1 f , It /e r' 1►Prn��, -fD ova r �c i,k-l'-Li Nameof = operator r(if:i.-li Ems _ rt 2 a_f 1'S'- ga../`> 7 �_or License No. 5C Y D 0 30 )dEstimatedCost of onStrue A 900 0, O By .. D I -oZo . � ,- 6. t__._ 1 1- 9 t— ),E,4 iau t--\'JC,K C A f t�_SL?c:cT1w FIRE PROTECTION NARRATIVE IN ACCORDANCE WITH MASSACHUSETTS STATE BUILDING CODE 780 CMR—901.7.1 PREPARED FOR: Fire Systems Inc 955 Reed Road N. Dartmouth, MA PROJECT: Eversource 484 Willow Street Yarmouth,MA November 3,2022 Page 1 A. Statement of Purpose: The following is provided to the Town of Yarmouth Building Department and Fire Department to satisfy the requirements of 780 CMR,the Massachusetts State Building Code Current Edition,and Chapter 9. We respectfully submit for your review,this Narrative for the proposed Fire Protection Sprinkler System at the above-referenced project. 1. Building Description Building Use Group—B Total Square Footage—1,100 sq.ft.Office renovation Approximate overall building height 24 ft Construction type—Concrete,Steel 2. Applicable Laws,Regulations and Standards - 780 CMR(9th Edition) Fire Protection Systems IBC&MSBC 9th Edition - NFPA 13 Standard for the Installation of Sprinkler Systems(2013 Edition) - NFPA 25 Inspection Testing and Maintenance of Water-Based Fire Protection Systems(latest Edition) 3. Design Responsibility for Fire Protection: After the FPE review and approval of the fire sprinkler shop drawings,the Yarmouth Building and Fire Department will also review and approve final shop drawings before installation of equipment,and issue appropriate fire sprinkler permits per 527 CMR 1 & 10. Glen Markey is considered the engineer of record and will certify system specification compliance at the completion of the project. 4. Fire protection System to be installed; The existing building is equipped throughout with a wet pipe sprinkler system. The scope of work for the office renovation space is to relocate 11 pendent and plug 1 penden The system will be shut down and returned to service each day. Page 5. Sequence of Fire Sprinkler Operation: Sprinkler head is held closed by a heat-sensitive glass bulb or link.The glass bulb or link applies pressure to a pip cap which acts as a plug which prevents water from flowing until the ambient temperature around the sprinkler reaches the rating of the sprinkler head(155 degrees). The bulb/link breaks as a result of the thermal expansion.Upon activation of a sprinkler head,water flows through the system,activating the alarm switch which is wired to an alarm panel.Water continues to flow until a control valve is closed. 6. Testing Criteria: The sprinkler contractor shall be responsible for arranging all testing of the system,including notifying the building officials,fire department and engineer. The testing criteria for the fmal acceptance shall be as defined by NFPA 13 section 25.2.1.4 7. Approval Requirements: The engineer of record shall certify that the fire sprinkler system modifications have been installed in accordance with the approved fire protection construction documents,complies with all laws, regulations and standards,and the pre-approved narrative report. END OF NARRATIVE ,. -,*,,,,,,,,,e, et, : ;„,/i0e, csi � 8 : ,..' E ..„. ',E,. , 0 �' e"y A 0 iftbilookt 00 TiIll i 4 ..... . . , +..., = ..,„: i a) (i) !, 41) c ...., .!I.?: , I(, _ ', :3 w 1:-. (..) .„um, a Iiiiii., r.°44‘,/ i S )1v (3),,,,. --,, 2 „,..1 "4"4° 00 4.,00„k. „.....,,,,,,,,LZ ty 03 2 ..... .i„,, , 1,2„;;;;,,,,,,t, , ,,,,,..7........ „„, ,_, „,se: uti ; -;_ ;;', 1'....,!,;9:3i:„...i.I: ,,,,,.:,,,,, „7.,;:.. :.,;(4i9j ' .... ;; o (till . - i,,.,, „:„;,,,,,, , ,,,,-.2. €�' ; ,,,,....,***- / / a I "6 —41). -; c a. ;,1).1!. .pti,„ i E ;.. (:)15 i1 27 Iv)" ' _id: a) : lb. U.11 ill 00.- C :48% 474 re g = 1 mat :-o ..... 'Ells csi •:( to 01 o 1 0 Naor 1 (,) cl. cvs) pit i.it (#) (,) i . ... 0 x !R.. o . . . t Initial Construction Control Document To be submitted with the building permit application by a Registered Design Professional * - for work per the 9th edition of the c Massachusetts State Building Code, 780 CMR, Section 107 Project Title:Eversource Date: November 2,2022 Property Address: 484 Willow Street,Yarmouth,MA Project: Check(x)one or both as applicable: New construction XX Existing Construction Project description: Relocate 11 existing pendent sprinklers to conform to new ceiling and wall floor plans I Glen Markey MA Registration Number Expiration date �u4�� ,am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning': Architectural Structural Mechanical XX Fire Protection Electrical Other: for the above-named project and that to the best of my knowledge, information,and belief such plans,computations and specifications meet the applicable provisions of the Massachusetts State Building Code,(780 CMR),and accepted engineering practices for the proposed project. I understand and agree that I(or my designee) shall perform the necessary professional services and be present on the construction site on a regular and periodic basis to: 1. Review,for conformance to this code and the design concept, shop drawings,samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Perform the duties for registered design professionals in 780 CMR Chapter 17,as applicable. 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the approved construction documents and this code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. When required by the building official,I shall submit field/progress reports(see item 3.)together with pertinent comments,in a form acceptable to the building official. Upon completion of the work,I shall submit to the building official a`Final Construction Control Document'. Enter in the space to the right a"wet"or �.cN OF Mqs, electronic signature and seal: ya zt GLEN & a MARKEY m MECHANICAL ` No.4154 ail Phone number:508-876-9718 Email: gmarkey@edesignservice.comi , �I Building Official Use Only Building Official Name: Permit No.: Date: Note 1.Indicate with an`x'project design plans,computations and specifications that you prepared or directly supervised.If`other'is chosen, provide a description. Version 06 11 2013 Version 06 11 2013