HomeMy WebLinkAbout105 Sisters Cir plan 1SHEET INDEX: GENERAL NOTES: AERIAL VIEW: PV-1.0 COVER SHEET 1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL. HAVE COMPLETE TEST DATA PV-2.0 SITE PLAN SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY 2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED �s ComprleteSolar 'x, ' 3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED A Brighter Way. k , h �7 s a+ PV-3.0 ROOF PLAN 4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER. 5. CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION. AND SHALL ,� - . , , s PV-4.0 ROOF ATTACHMENTS COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED. 6. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS COMPLETE SOLAR 3q PV-5.0 MOUNTING DETAIL AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY AND COMPLY WITH ALL UTILITY 3000EXECUTIVE PKWY.STE504 •f~ T� a � �T9'r � � e' COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS VOER THE BUSS SIZE 20% �LCENSETYPE C403 '_ICENSE#A17161 % I PV-6.0 LINE DIAGRAM LIMIT, CONTRACTOR SHALL INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIM BOARD LICENSE # Al- 1509 f ^..�5.`. ,• CAPACITY. PHONE # (877) 299-4943 t +.„ "A,� PV-7.0 LABELS 7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED �— WITH OTHER TRADES. 8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, r " PV-8.0 PLACARD CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WITHSTANDING THE EXTRA WEIGHT. U; I m 9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR I�01 SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE SIRE SIZE. FINAL DRAWINGS WILL BE RED -LINED AND UPDATED AS APPROPRIATE. f ' * 10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE _ BERRY fi DRAWINGS OR IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF "v THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS. JASON BERRY PROJECT 11. ALL BROCHURES, OPERATION MANUALS, CATALOGS, SHOP DRAWINGS, ETC. SHALL BE ' . , ✓ a " ` " HANDED OVER TO OWNER'S REPRESENTATIVE AT THE COMPLETION OF WORK 105 SISTERS CIR YARMOUTH PORT, MA 02675 LAT , LONC : 41.689908,-70.2584813 GOVERNING CODES: Ic SCOPE OF WORK: -' THE INSTALLATION OF SOLAR ARRAY AND ' PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING PV ROOF MOUNT INSTALLATION OF CODES: 22 CERTAINTEED - CT365HC11-06 MODULES, VICINITY MAP: NEC2020 SITE INFORMATION: 22 ENPHASE IQ8PLUS-72-2-US INVERTER(S), MASSACHUSETTS BUILDING CODE, 9TH EDITION MAX CONTINU0732 CSYSTEMSIZE: AS AMENDED (780CMR) EXISTING 200A MAIN SERVICE PANEL WITH 2O0A MAIN MASSACHUSETTS RESIDENTIAL BUILDING CODE, 9TH EDITION DC SYSTEM SIZE: 8.03 AS AMENDED (780 CMR) METER CONNECTION: UNDERGROUND {22)CERi'aIN�ODULES365HC1106 MASSACHUSETTS COMPREHENSIVE FIRE SAFETY CODE (527 CMR 1.00) NO TRENCHING „ )) (22) ENPHASE IQ8PLUS-72-2-US INVERTER(S) MOUNTING EQUIPMENT: ALL OTHER ORDINANCE ADOPTED BY 7.. ,► UNIRACSM&UNIRAC- PLASHLOC COMP THE LOCAL GOVERNING AGENCIES rf SITE SPECIFICATIONS: SYSTEM INFORMATION:~, ZONING: RESIDENTIAL DC SYSTEM SIZE:8.03 DESIGNED BY: BRAD NEWMAN Sighed 8/22/2022 OCCUPANCY GROUP: R-3 MAX CONTINUOUS AC SYSTEM SIZE: 7.32 COMPLETE SOLAR CONSTRUCTION TYPE: V-g DATE: August 12, 2022 NUMBER OF STORIES: 2 EQUIPMENT INFORMATION: COWER SHEET 4„ ROOF LAYERS: 1 (22) CERTAINTEED - CT365HC11-06 MODULES FIRE SPRINKLERS PRESENT: N (22) ENPHASE IQ8PLUS-72-2-US INVERTER(S) - MOUNTING EQUIPMENT: UNIRAC SM &UNIRAC - FLASHLOC COMP - 48" O.C. Pv_l no AHJ: YARMOUTH TOWN