Loading...
HomeMy WebLinkAbout105 Sisters Cir plan 10IQ8 and IQ8+ Microinverters Our newest I08 Microinverters are the industry's first microgrid-forming, software - defined microinverters with split -phase power conversion capability to convert DC power to AC power efficiently. The brain of the semlconductor-based microinverter is our proprietary application-speclfic integrated circuit (ASIC) which enables the microinverter to operate in grid -tied or off -grid modes. This chip Is built in advanced 55nm technology with high speed digital logic and has super -fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. ­01010- Part of the Enphase Energy System, I08 Series Microinverters integrate with the Enphase IQ Battery, Enphase IQ Gateway, ant the Enphass App monitoring and analysis software. Connect PV modules quickly and easily to 108 Series Microinverters using the included Q-0CC-2 adapter cable with plug-n-play MC4 connectors. I08 Series Microinverters redefine reliability standards with more than one million cumulative hours of power -on testing, enabling an industry -leading limited warranty of up to 25 years. I08 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer's Instructions. 0 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, toe microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. 108SP-DS-0002-01-EN-US-2021-10-19 Easy to install • Lightweight and compact with plug-n-play connectors • Power Line Communication (PLC) between components Faster Installation with simple two -wire cabling High productivity and reliability Produce power even when the grid Is down More than one mlliion cumulative hours of testing • Class II double -insulated enclosure • Optimized for the latest high- powered PV modules Microgrid-forming Complies with the latest advanced grid support • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles Meets CA Rule 21(UL 1741-SA) requirements IQ8 and IQ8+ Microinverters Commonly used module pairings' w ., 235 - 350 235 - "0 Module compatibility 60-cell/120 half -toll 60-oell/120 half -cell and 72-tail/144 half -cell MPPT voltage range V 27-37 29-45 Operating range V 25 - 48 25 - 58 Min/max start voltage V 30 / 48 30 / 58 Max input DC voltage v 50 80 Max DC currerri` [module lac] A 15 Overvoltage class DC port 11 DC port baokfeed current MA 0 PV array configuration 1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch cirouf Peakoutputpower VA 245 300 Max continuous output power VA 240 290 Nominal (L-L) votags/range' V 240 / 211- 254 Max continuous output current A 1.0 1.21 Nominal frequency Hz 80 Extended frequency range Hr 50 - 68 Max units per 20 A (L-L) branch anwit" 18 13 Total harmonic distortion <5% Overvoltage class AC part III AC port backfeed current mA 30 Power factor setting 1.0 Grid -tied power factor (adjustable) 0.85leading - 0.85lagging Peak efficiency 1i 975 97.0 DEC weighted efficiency Y, 97 97 Night-time power consumption mw 80 Ambient temperature range -40-C to+60°C (40"F to +140°F) Relative humidity range 4%to 100% (condensing) OC Connector type MC4 Dimensions (HxWXD) 212 mm (8.3") x 175 mm (8.9") 00.2 mm (1a") Weight 1.08 kg (2.381bs) Cooling Natural convection -no fans Approved for wet locations Yes. Acoustic noise at 1 m <60 daA Pollution degree PDa Enclosure Class 11 double -insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor CA Rule 21(UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 1.5 Class B, ICES-0003 Class a, CAN/CSJ1-C22.2 NO. tOZt-i Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 54-218 Rapid Shutdown of PV Systems, for AG and DC conductors, when installed according tc manufacturer's instructions. (1) No enforced DC/AC ratio. See the compatibility calculator at https://IiriLonphase coml module -compatibility (2) Maximum continuous input DC current is 10.8A (3) Nominal voltage range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQBSP-DS-0002-01-EN-US-2021