Loading...
HomeMy WebLinkAbout105 Sisters Cir plan 510 PV MODULE RAIL FLASHLOC ATTACHMENT (E) COMP SHINGLE ROOF (1 LAYER) FLASHING 5/16" STAINLESS STEEL LAG -BOLT WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER (E) ROOF FRAMING DETAIL, MOUNTING AND FLASHING 1 wl 2 11 MAX." FRONT VIEW PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: ROOF ATTACHMENT COUNT: 49 PV MODULE COUNT: 22 ARRAY AREA: MODULE COUNT' 19.63 = 431.86 ROOF AREA: 2275 W PERCENT OF ROOF COVERED: 19% ARRAY WEIGHT: MODULE COUNT' 45.19lbs = 994.18 DISTRIBUTED LOAD: ARRAY LBS/ATTACHMENTS = 20.29 POINT LOAD: (Ibs/ ft2) _ (ARRAY) WEIGHT/AREA = 2.3 Ibs/ fta PV MODULE RAIL (E) RAFTER/TOP CHORDS RAIL FLASHLOC ATTACHMENT 21-811 Nlf V 3'-10" MAX (E) RAFTERJTOP CHORD M s 7;i Signed 8/22/2022 4 10"MIN - 7 1'-4" MAX m 21_811 I /IN—- 3'-10" MAX SIDE VIEW END CLAMP PV MODULE RAIL CornpleteSOlar A Brighter Woy.I. 3000 EXECUTIVE PKWY,STE 504 SAN RAMON, CA 94583 LICENSE TYPE C10 _ICENSE # A17W BOARD LICENSE # Al-1509 P%HONE # (877) 299-4943 10" MIN - 1 '-411 MAX BERRY JASON BERRY PROJECT 105 SISTERS CIR YARMOUTH PORT, MA 02675 LAT,LONC-:41.689908,-70.2584813 SITE INFORMATION: MAX CONTINUOUS AC SYSTEM SIZE: 7.32 DC SYSTEM SIZE: 8.03 MID CLAMP (22) CERTAINTEED - CT365HC11-06 MODULES (22)ENFHASEIQ8PLUS-72-2-US INVERTER(S) PV MODULE MOUNTING EQUIPMENT: UNIRAC SM & UNIRAC - FLASHLOC COMP RAIL 2 END CLAMP DETAILS 3 MID CLAMP DETAILS MOUNTING EQUIPMENT: ROOF & FRAMING INFORMATION: ROOF ATTACHMENT COUNT: 49 _ ROOF TYPE: Comp Shingle PV MODULE COUNT: 22 FRAMING TYPE: Rafters SPLICE COUNT: 4 RAFTER SIZE: 2X8 MID CLAMP COUNT: 36 RAFTER SPACING: 16, END CLAMP COUNT: 16 ATTACHMENT SPACING: 48" O.C. DESIGNED BY: BRAD NEWWN COMPLETE SOLAR DATE: August 12, 2022 MOUNTING DETAIL