Loading...
HomeMy WebLinkAbout105 Sisters Cir plan 7AT POINT OF INTERCONNECTION, MARKED AT DISCONNECTING MEANS [NEC 690.54] AWARNING DUAL POWER SOURCE AT POINT OF INTERCONNECTION. SECOND SOURCE IS,PI jTQVOLTAIC SYST€ [NEC 705.12(D)(3)] ELECTRICAL SHOCK HAZARD DO NO TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION EACH PV SYSTEM DISCONNECTING MEANS SHALL PLAINLY INDICATE WHETHER IN THE OPEN (OFF) OR CLOSED (ON) POSITION AND BE PERMANENTLY MARKED [NEC. 690.13(B)] AT EACH DC DISCONNECTING MEANS [NEC 690.13(B)] AT EACH AC DISCONNECTING MEANS [NEC 690.13(B)] AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS [NEC 690.31(G)(3)] AT BUILDING OR STRUCTURE MAIN DISCONNECTING MEANS. [NEC 690.12(E), NEC 690.151 -- RYA RN'I N V PERMANENT WARNING LABELS SHALL BE APPLIED TO �Y N N DISTRIBUTION EQUIPMENT THE EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OFALL OVERCURRENT DEVICES, EXCLUDIN3 MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OFBUSSA,R A PERMANENT WARNING LABEL SHALL BE APPLIED TO A& Y,fit ARNING THE DISTRIBUTION EQUIPMENT ADJACENT TO THE INVERTER OUTPUT CONNECTION. DO NOT BACK -FED BREAKER FROM THE INVERTER. RELOCATE THIS OVERCURRENT DEVICE [NEC 705.12(D)(2)(3)(b)] SOLAR PV SYSTEM EQUIPPED FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND WITH RAPID SHUTDOWN CONDUCTORS LEAVING THE ARRAY: — THE TITLE "SOLAR PV SYSTEM IS EQUIPPED WITH TURN RAPID SHUTDO N RAPID SHUTDOWN" SHALL UTILIZE CAPITALIZED 'OFPPOS ONTO CHARACTERS WITH A MINIMUM HEIGHT OF 3/8 IN. IN BLACK SHU EM AND REDUCII PV E ON YELLOW BACKGROUND, AND THE REMAINING SHIN°AR AYRDILI CHARACTERS SHALL BE CAPITALIZED WITH A MINIMUM HEIGHT OF 3/16 IN. IN BLACK ON WHITE BACKGROUND. [NEC 690.56(C)(1)(A)] LABELING NOTES: 1. LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 2. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 3. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.211 4. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL LOCATED ON OR NO MORE THAN 3 FT FROM THE SWITCH THAT INCLUDES THIS WORDING. THE LABEL SHALL BE REFLECTIVE, WITH ALL LETTERS CAPITALIZED AND HAVING A MINIMUM HEIGHT OF 3/8 IN., IN WHITE ON RED BACKGROUND.[NEC 690.56(C)(2)] CompleteSolar A. Brigh-ar Way, 3000 EXECUTIVE PKWY,STE 504 SAN RAMON, CA 94583 LICENSE TYPE C10 '+.ICENSE # A17161 BOARD LICENSE # Al-1509 PHONE # (877) 299.4943 BERRY i JASON BERRY PROJECT 105 SISTERS CIR YARMOUTH PORT. MA 0267'5 LAT, LONC-:41.689908,-70.2584813 SITE INFORMATION: MAX CONTINUOUS AC SYSTEM SIZE: 7.32 DC SYSTEM SIZE: 8.03 (22) CERTAINTEED - CT365HC11-06 MODULES (22) ENPHASE IQSPLUS-72-2-US INVERTER(S) MOUNTING EQUIPMENT: UNIRAC SM & UNIRAC - FLASHLOC COMP DESIGNED BY: BRAD NEWWN • COMPLETE soIAR DATE: August 12, 2022 LABELS PV-7.0