HomeMy WebLinkAbout21 Stiles Rd solar plans 1CODES:
ROOF MOUNT PHOTOVOLTAIC SYSTEM
THIS PROJECT COMPLIES WITH THE FOLLOWING:
2015 INTERNATIONAL BUILDING CODE (IBC) W/780 CMR
2015 INTERNATIONAL RESIDENTIAL CODE (IRC) W/780 CMR
2018 INTERNATIONAL MECHANICAL CODE (IMC)
2018 INTERNATIONAL PLUMBING CODE (IPC)
2018 INTERNATIONAL FUEL GAS CODE (IFGC)
2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
2015 INTERNATIONAL EXISTING BUILDING CODE (IEBC) W/780 CMR
2018 INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC)
2020 NATIONAL ELECTRICAL CODE (NEC)
AS ADOPTED BY TOWN OF YARMOUTH (MA)
VICINITY MAP:
�r-
l>
���yk rtt
SITE LOCATION
TABLE OF CONTENTS: I
PV-1
PV-2
PV-2A
PV-3
PV-4
PV-5
PV-6
PV-7
PV-7A
PV-8
PV-9
PV-10
APPENDIX
SITE LOCATION
SITE PLAN
ROOF PLAN WITH MODULES LAYOUT
MOUNTING DETAILS
THREE LINE DIAGRAM
CONDUCTOR CALCULATIONS
EQUIPMENT & SERVICE LIST
LABELS
SITE PLACARD
OPTIMIZER CHART
SAFETY PLAN
SAFETY PLAN
MANUFACTURER SPECIFICATION SHEETS
CONSTRUCTION NOTES:
CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND
ARE NOT MEANT TO LIMIT UP -SIZING AS REQUIRED BY FIELD CONDITIONS.
ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT
POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE
MOUNTED.
MODULES SHALL BE TESTED, LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN
ACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER
SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD.
DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY
EXCAVATION TAKING PLACE
PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM
DC DISCONNECT/INVERTER AS PER 2020 NEC SEC 250.166(A).
SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH
REQUIREMENTS OF ART. 690 OF THE 2020 NEC
THE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER
UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM
SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDS
INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT
ATTACHED TO THE ROOF USING CONDUIT MOUNT.
CLIENT:
BRIAN MORIN
21 STILES ROAD, YARMOUTH, MA 02664
AHJ: TOWN OF YARMOUTH (MA)
UTILITY: EVERSOURCE ENERGY (EASTERN
MA)
PHONE: (508) 737-1049
EMAIL: BMORIN21@YAHOO.COM
SYSTEM:
SYSTEM SIZE (DC): 19 X 370 = 7.030 kW
SYSTEM SIZE (NEC): 5.000 kW @ 240V
MODULES: 19 X FREEDOM FOREVER:
FF-MP-BBB-370
OPTIMIZERS: 19 X SOLAREDGE S440
INVERTER: SOLAREDGE SE5000H-US [S11]
REVISIONS
NO. REVISED BY DATE
freedom
€ V E F
FREEDOM FOREVER LLC
135 ROBERT TREAT PAINE DR., TALTON, MA
02780
Tel: (800) 385-1075
GREG ALBRIGHT
CONTRACTOR LICENSE:
HOME IMPROVEMENT CONTRACTOR 198080;
BUSINESS ELECTRICAL CONTRACTOR LICENSE
902-EL-Al; CONSTRUCTION SUPERVISOR
LICENSE CS-111662, MASTER ELECTRICIAN
1136 MR
SITE LOCATION
JOB NO: I DATE: DESIGNED BY: SHEET:
262874 9/7/2022 Z.V.I PV-1