Loading...
HomeMy WebLinkAbout21 Stiles Rd solar plans 1CODES: ROOF MOUNT PHOTOVOLTAIC SYSTEM THIS PROJECT COMPLIES WITH THE FOLLOWING: 2015 INTERNATIONAL BUILDING CODE (IBC) W/780 CMR 2015 INTERNATIONAL RESIDENTIAL CODE (IRC) W/780 CMR 2018 INTERNATIONAL MECHANICAL CODE (IMC) 2018 INTERNATIONAL PLUMBING CODE (IPC) 2018 INTERNATIONAL FUEL GAS CODE (IFGC) 2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2015 INTERNATIONAL EXISTING BUILDING CODE (IEBC) W/780 CMR 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC) 2020 NATIONAL ELECTRICAL CODE (NEC) AS ADOPTED BY TOWN OF YARMOUTH (MA) VICINITY MAP: �r- l> ���yk rtt SITE LOCATION TABLE OF CONTENTS: I PV-1 PV-2 PV-2A PV-3 PV-4 PV-5 PV-6 PV-7 PV-7A PV-8 PV-9 PV-10 APPENDIX SITE LOCATION SITE PLAN ROOF PLAN WITH MODULES LAYOUT MOUNTING DETAILS THREE LINE DIAGRAM CONDUCTOR CALCULATIONS EQUIPMENT & SERVICE LIST LABELS SITE PLACARD OPTIMIZER CHART SAFETY PLAN SAFETY PLAN MANUFACTURER SPECIFICATION SHEETS CONSTRUCTION NOTES: CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP -SIZING AS REQUIRED BY FIELD CONDITIONS. ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE MOUNTED. MODULES SHALL BE TESTED, LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN ACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY EXCAVATION TAKING PLACE PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM DC DISCONNECT/INVERTER AS PER 2020 NEC SEC 250.166(A). SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ART. 690 OF THE 2020 NEC THE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDS INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNT. CLIENT: BRIAN MORIN 21 STILES ROAD, YARMOUTH, MA 02664 AHJ: TOWN OF YARMOUTH (MA) UTILITY: EVERSOURCE ENERGY (EASTERN MA) PHONE: (508) 737-1049 EMAIL: BMORIN21@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 19 X 370 = 7.030 kW SYSTEM SIZE (NEC): 5.000 kW @ 240V MODULES: 19 X FREEDOM FOREVER: FF-MP-BBB-370 OPTIMIZERS: 19 X SOLAREDGE S440 INVERTER: SOLAREDGE SE5000H-US [S11] REVISIONS NO. REVISED BY DATE freedom € V E F FREEDOM FOREVER LLC 135 ROBERT TREAT PAINE DR., TALTON, MA 02780 Tel: (800) 385-1075 GREG ALBRIGHT CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-Al; CONSTRUCTION SUPERVISOR LICENSE CS-111662, MASTER ELECTRICIAN 1136 MR SITE LOCATION JOB NO: I DATE: DESIGNED BY: SHEET: 262874 9/7/2022 Z.V.I PV-1