HomeMy WebLinkAbout122 Exeter Rd plan 1THE PEWA- OF r PERFECTION i 1� �yF of PA, LLC. 7172 ROUT' 522 ff10PLEBUR6!, P,4 17842 PHONE.• (570) 837-2333 APPLICABLE CODES MA SINGLE AND TWO FAMILY DWELLING CODE (780 CMR) 9TH EDITION MA FUEL / GAS / PLUMBING CODE (248 CMR) 2015 INTERNATIONAL MECHANICAL CODE w/ AMENDMENTS 2020 NATIONAL ELECTRICAL CODE w/ MA AMENDMENTS 2018 INTERNATIONAL ENERGY CONSERVATION CODE W/ MA A ENDMENTS MC NIUMBER: 150 TPTA NUMBER: 02 DESIGN CRITERIA R . wtSl YARMOUT.. MA USE GROUP ONE FAMILY CONSTRUCTIDN TYPE VB WOOD FRAME UNPROTECTED FOUNDATION BASEMENT - UNCONDITD7NED ROOF PITCH: 9/12 FLOOD ZONE: AE # OF STORIES 1 SQ, FT: -LIMATE ZONE 5 EXPOSURE C SITE CLASS: D SEISMIC DESIGN B 1ST FLR: 1755 SOFT. CATEGORY AS PER ASCE 7- 7 UNBALANCED SNOW 1.5 ALL CASES FACTOR: RAFTERS: C16° O.CJ TOP CHORD LIVE LOAD = 17 PSF TOP CHORD DEAD LOAD = 15 PSF BOTTOM CHORD LIVE LOAD = 20 PSF BOTTOM CHORD DEAD LOAD = 10 PSF CEILING JOISTS: SLEEPING AREA - LIVE LOAD = 30 PSF STORAGE - LIVE LOAD = 20 PSF DEAD LOAD = 10 PSF ❑R ACTUAL WEIGHT FLOORS: NON -SLEEPING AREAS - LIVE LOAD = 40 PSF SLEEPING AREAS - LIVE LOAD = 30 PSF DEAD LOAD = 10 PSF FIRE PROTECTION SMOKE ALARMS AS PER STATE CODES SYSTEM: CARBON MONOXIDE DETECTORSIPER STATE CODES FLAME SPREAD _IS LESS THAN''< 200 - .. 1 rt uNtLK tUR INSULATION VALUES V NTILATIDN: BATH FANS TO PROVIDE A MINIMUM. AIR EXCHANGE OF 50 CFM KITCHE RANGE EXHAUST FAN TO PROVIDE AN AIR EXCHANGE OF 100 CFM .RADON VENT COMPLYING -WITH IRC APPENDIX F SHALL BE INSTALLED WHERE REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION. NOTE: VENTS MUST BE DESIGNED FRO THE ROOM. SIZE/EQUIPMENT PER MANUFACTURERS SPECICATIONS. BUILDER TO INSTALL A WHOLE HOUSE VENTILATION SYSTEM TO MEET THE REQUIREMENTS OF TABLE R403.6.1. SOUND RATING FOR FANS USED FOR WHOLE HOUSE VENTILATION TO BE RATED AT A MAXIMUM OF I SOME PER N1103.6.4 (NINTH EDITION RESIDENTIAL CODE) HEAT ❑N-SITE BY BUILDER MA STRETCH ENERGY CODE: YES DRAWING INDEX 'AGE # DESCRIPTION CONSTRUCTION SUPE SITE PLAN Al COVER SHEET AL1 GENERAL NOTES A1.2 DOOR AND WINDOW Q2-A3 ELEVATI➢NS A4 1ST FLR FLOOR PLA AS 1ST FLR ELECTRICA A6 FOUNDATION PLAN A7 1ST FLR SHEAR WAL A8 CROSS SECTION A9 9/12 27'-6' RAFTER A10 9/12 22'-6° RAFTER A11 DORMER/PORCH RAFTI Al2 WALK OUT BAY DETA A13 DWV/SUPPLY PLUMBS A14 PLUMBING DETAILS AIn I LVL FASTENING DET, A16 ELECTRICAL LOAD CA HOME ENERGY RATTNF AND ENERGY RATING TO BE DONE ON -SITE BY THE BUILDER ­LKuy�LSi1NG ENERGY TESTING AGENCY: RICK TERRY - 570-660-1122 764 DRY RUN ROAD BEECH CREEK,PA 16822 STRUCTURAL CALCULATIONS (20 S) 2' VENT STACKS REPLACING 1 1/2' PER CODE NOTICE A 48-HOUR NOTIFICATION IS REQUIRED PRIOR TO SET. THE CSL ON TOTAL PAGES = 61 TOTAL RECORD WILL RELAY THIS TO THE LOCAL AUTHORITY. IF ANY ADHESIVE ONLY METHODS OF ATTACHMENT OF GYP BOARD CONNECTIONS F HAVE BEEN CONCEALED PRIOR TO INSPECTION, THE DOCUMENTATION ❑F ADHESIVE ONLY ATTACHMENT MUST BE SHOWN ❑N MODULAR PLAN BUILDING OFFICIAL MAY REQUEST HAVING THE REMOVAL OF ELEMENTS THAT CONCEAL THE CONNECTIONS TO PROVIDE ACCESS, THIS WOULD DRAWINGS. MANUFACTURERS MUST IDENTIFY WHERE ADHESIVE ONLY NOT CONSTITUTE 'DESTRUCTIVE DISASSEMBLY'. ALL CONNECTIONS ON ATTACHMENT OF GYPSUM SITE MUST BE INSPECTED BY THE LOCAL AUTHORITY, BOARD I: PROHIBITED AND WILL NOT BE USED. ADHESIVE ONLY ATTACHMENT GYPSUM BOARD IS PROHIBITED IN THE FOLLOWING LOCATION; THIS HOME IS SOLAR PANEL READY (RESIDENTIAL) RAFTERS ARE DESIGNED TO SUPPORT 5 PSF MAX ADDT'L DEAD LOAD 1. ➢EMISING WALLS .BETWEEN GARAGE AND HOUSE. 2. FIRE WALLS, FIRE BARRIERS, FIRE SEPARATION WALLS, PARTITIONS, FLOOR A FOR POTENTIAL SOLAR PANELS, CEILING ASSEMBLIES. ND 3. WHERE OR COATED GYPSUM SOLAR PANELS MUST BE INSTALLED PARALLEL TO ROOF SLOPE WITH 4. WHERE SHEETATED VAPOR RETARDERS ARE APPLRID DISTO G HBE INSIDE L RD GYPSUM FACE OF MAX VERTICAL OFFSET OF 12 INCHES, STUD CONSTRUCTION. 5, WHERE LIMITED IN 'HIGH WIND DESIGN' AS A FACTOR OF THE WALL ASSEMBLIES'. WIND RESISTANCE 6. CEILINGS GENERAL NOTES 1. THE ENCLOSED PLANS AND SPECIFICATIONS ARE THE PROPERTY ❑F APEX HOMES OF PA LLC THE METHODS OF CONSTRUCTION DETAILED. WITHIN SHALL BE KEPT CON-LUENTIAL. ANY UNAUTHORIZED USE OF THESE DRAWINGS WITHOUT THE CONSENT OF APEX HOMES, INC. IS PROHIBITED. 2, AMEX HOMES OF PA LLC WILL BE CONSIDERED AS A 'SUBCONTRACTOR' IN ALL BUILDING PROJECTS, SUPPLYING A BUILDING COMPONENT TO A 'GENERAL CG^:TRACTOR' OR 'BUILDER'. THE SPECIFICATIONS ENCLOSED ARE FOR DESCRIBING AND DETAILING THE PROPER USE OF OUR MANUFACTURED BUILDING MODULE AND ITS CONSTRUCTION. COMPLETE PROJECT BUILDING DESIGN ( i.e. SITE, FOUNDATION, DECK, OR PORCHES, ETC. ) SHALL BE BY THE 'GENERAL CONTRACTOR'. ALL NOTES PERTAINING TO 'IN FIELD", ON SITE OR 'BY BUILDER' SHALL BE THE RESPONSIBILITY OF THE 'GENERAL CONTRACTOR'. 3. THESE PLANS MUST NOT. BE SCALED FOR DIMENSIONAL REFERENCE, ALL DIMENSION LINES AND NOTES SUPERSEDE ANY SUCH REFERENCES, 4. THERMAL TRANSMITTAL VALUES FOR ROOF, WALL AND CEILING LOCATED ON REScheck SN-11884/ QN-17596/JN-72304/MA "ALL. SITE CONNECTIONS TO SITE COMPLETION REQUIREMENTS: CONSTRUCTIONBSUPERVISOR ATTENTION LOCAL BUILDING OFFICIAL THIRD PARTY APPROVAL APPLIES ONLY TO THE FACTORY BUILT PORTION OF THIS BUILDING AND ADDITIONAL WORK IS REQUIRED ❑N-SITE. ALL WORK TO BE COMPLETED UN -SITE IS TO BE IN COMPLIANCE WITH ALL STATE AND LOCAL CODES AND IS SUBJECT TO REVIEW, APPROVAL, AND INSPECTION BY THE LOCAL AUTHORITY HAVING JURISDICTION. THIS BUILDING IS DESIGNED FOR INSTALLATION ON A PERMANENT FOUNDATION AND IS. NOT INTENDED TO BE MOVED ONCE INSTALLED. ALL ON -SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR WITH EXPERIENCE IN THE SETUP OF MODULAR BUILDINGS. THE FOLLOWING LIST IS NOT ALL INCLUSIVE, NOR DOES IT LIMIT THE ITEMS OF WORD OR MATERIALS THAT MAY BE REQUIRED FOR COMPLETE INSTALLATION. 1. ALL MATERIALS FOR THE FOUNDATION, INCLUDING SUPPORT COLUMNS AND CONNECTIONS AND ANCHORAGE SYSTEM.- 2. .DECKS, POSTS RAMPS, STAIRS, HANDRAILS AND GENERAL ACCESS TO BUILDING 3. PORTABLE FIRE. EXTINGUISHER'S), IF REQUIRED. 4. CONNECTION FOR FIRE PROTECTION SYSTEM (CO DETECTORS/SMOKE DETECTORS ETC.) (IDENTIFIED ON PLAN) 5. BUILDING DRAINS, CLEAN OUTS, AND CONNECTION TO PLUMBING SYSTEM COMPLETED AND .TESTED ❑N-SITE. 6. ELECTRICAL : SERVICE CONNECTION (INCLUDING FEEDERS) TO THE BUILDING. ELECTRICAL PANEL DISCONNECT AND SERVICE ENTRY WIRE 7. CONNECTION OF ELECTRICAL CIRCUITS CROSSING OVER MODULE MATING LINES) (MULTI -UNITS ONLY). B. ELECTRICAL '..FIXTURES NOT INSTALLED IN THE PLANT. 9, WHEN EXTERIOR RECEPTACLES ARE PROVIDED AND ARE NOT ACCE IBLE FROM GRADE DUE TO SIDE CONDITIONS, ADDITIONAL RECEPTS SHALL BE INSTALLED. 10. EXTERIOR SHINGLES, SIDING, WALL FINISH AND SOFFIT MATERIAL, NO INSTALLED IN THE FACTORY. 11. UNFINISHED ATTIC SPACES (IF THEY ARE TO BE FINISHED). 12. STORM SHUTTERS, IF APPLICABLE. 13. FIRE STOPPING AT MATELINES, 14, ALL HVAC COMPONENTS DESIGNED AND INSTALLED ON -SITE BY UILDER. l5. INSULATION AND AIR SEALING OF CEILING. ACCESS PANELS 16. RODENT PROOFING 17. ON -SITE ROOF CONNECTIONS LISTED ON PAGE RAFTER SECTI NS OF PERMIT SET I& GUTTERS AND DOWN SPOUTS '..9. RIDGE VENT COMPLETION '_0. INTERCONNECTION OF MODULAR UNITS TO EACH OTHER AND T 1ST FLOOR '1. ON -SITE TILE, FLOORING '_2. ALL WATER SUPPLIES AND DRAINS BELOW THE 1ST STORY FLOOR ISTS '_3. INSTALLATIONS OF ALL GAS LINES '4. ON -SITE APPLIANCES. 'S. IAATIDN FLOOR INSULATION '.6. AIRIR LELEAKAGE ': TESTING '. INSULATED FLEX DUCT FROM BATHROOM FANS DIRECTLY TO THE EXTERIOR 2. FURNACE/AIRHANDLER AND DUCTWORK ''9. WATER HEATER AND INSTALLATION M. EXTENSION OF VENTS AND/OR CHIMNEYS THROUGH THE ROOOF TO THE OUTSIDE ,L SITE SUPPLIED WOOD. STRUCTURAL PANELS WITH A MINIMUM OF 7/16 INCH THICKNESS AND A MAXIMUM SPAN OF 8 FEET SHALL BE PROVIDED FOR OPENING PROTECTION IN ONE AND TWO STORY BUILDINGS.PANELS SHALL BE PRE-CUT S❑ THAT THEY CAN BE ATTACHED TO THE FRAMING SURROUNDING THE OPENING CONTAINING THE PRODUCT WITH THE GLAZED OPENING. PANELS SHALL BE, FASTENED TO THE DWELLING IN ACCORDANCE WITH TABLE R301.2.1.2. THESE PANELS WILL BE PROVIDED AND INSTALLED ON -SITE BY BUILDER FOR STATE USE ONLY �RVAN BORING:?: O BO% THIRD PARTY SEAL LOCATION NHA.ei,IN a65�5 REVIEWED FOR CODE COMPLIANCE OF Ma RYAN W. BORING CIVIL NO.49506 t n PO��SFG I STEEt� y � L EN \+ \I eb 22, 2022 jPFS Corporation Approval Limited to Factory -Built Portion Only State: Massachusetts Signature: Nlalc elle Ba& Title: Staff Plan Reviewer Date: 02/22/2022 El L�l U Q Li U 0 J Z 2 EL I U 0_ D 0_ RCi V M �lo ryy4 1p� cy ti o z` �aZs �1 BE T�,,P OF FOUNDATION 40 FT, MINIMUM FROM Etl`v, 10 FT. MINIMUM 10 FT, MINI! I 'CON C RE 11 C,'OVERS Y_ v &00 4" CAST IRON PIPE —t+�-_Ti (OR ECAJAL) MINiMOM 1 4" PER FT, ;LAB ELEV, FLOW LI El EV, CRA 4" SCHEDULE 40 P,/C_ PIPE MIN. IN. PITCH li,/$" PER FT. m CLEAN SANV 7iNSPECTION PORT -,LOAM ANT) SEED 2' LAfER OF 14�03 MAX WASH, i. D STOt4E OR Pi TER FAPRjC. 11.78 MIN. LJ MIN. -E LF-v. LEVEL ELE"", GA ELEV� Wo ELE BAFFLE DISTRIBUTION OtJ TLETT--=€ ELEV SIE$ut 8.65 BOX _JoJu__/ �___F_EY_T_ __TLL__� (TO BE. PLACED ON FIRM BASE) 4 14 1, N WA IN 10 BLE �ER TIES IED 5 FEE T IN ES )4 IF M(,)RE THAN ONE OUTLET 6 FEET 1500 GALLON IN H� 7 FEET 9 1 ES (TO BE PLACED ON FIRM BASE) FEET 14 'ES i SEP11C TANK CLEAN 3/4" TO 1/2' DOUBLE 'WASHED STONE FREE C)F FINIS & 311,T r*`2"AS5 SWALE SEWAGE DISPOSAL SYSTEM PROnLE NOT TO SCALE , GPASS '550D OR EROSION CONTROL SEED mix" wu,,,4v & wumurN r A- '�' JURF REINFORC. I EMENT MAT 6" TOPSOIL S 1E 6" COMPACTED GRAVEL BASE I MAINTAiN SM0O_rH LONGITUDINAL GPADEL ALL ALONG SWALE. KRISnN 6AL4AHAAi '00' LOT 16 2 INSTALL T(JRF 'REINFORCEMENT MAT 14, 1 J 1, 4 PER MANUFACTURER'S INST 'RUCTIONS RI HARD T. KILRO)r', N & 8 70 A(A?7iCEEN A- BArEMAN 7.67 1p, SDI L ,o 0, 3 7163 _X 1po SOIL I GA LO� C, TEST 1 C ANK 7.57 0 M 'AN 14 A S DA? L "At TFST 4 i A, In 1A F.54 AlK PEMOV 6' 94 LEGEND: EXISTING SPOT ELEVATION 'ATION 00,0 E)OSPING CONTOUR FINAL SPOT ELEVATION FINAL CON TOUR SOIL TEST LOCATION UTILITY POLE --0- T,OWN WATER —W--so—W CATCH BASIN' 0 A S J N E CLEAN OUT CES'spcol_ c., P Q co 71 REQUiREL CLE'_= L­ 11 , .05 ­ 40 W L**R JJW 2000 ZONE INDEX 0 At; JUT ELEV. FEB. 2D22 USGS PROBABLE WA TER TA8LE EL9"v- = ZONE OBSER'OED WATER TABLE f2/2/2022) ELEV. = INDEX- (1/2022) 801TTOM OF TEST l'4'..)LE ELEV, = ADJUST . 83 ;2; 3 2 8 NOTES: ALL WORKMANSHIP AND MATERIALS Si4ALL CONFORM TO Dl P rlTLE 5 AND THE TOWNS RULES AND REGQ. ATIONS FOR THE SLISSURFACIE DISPOSAL OF SEWAGE, Al.- COVERS TO SANITARY LINiTS SHALL BE BROUGHT TO w THIN 6" OF FINISHED GRADE. ALL I C,,WPOt,4ENT8 OF THE SANITARY SYSTEM SHALL BE CAPAR-E OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHfN 10 FT. OF DRIVES OR PARKING AREAS, H-20 LOADING SHALL BE USED UNDER OR' WITHIN 10 FT. OF DRIVES OR PARKING AREAS. ANY MASC)NARY UNITS USED TO BRING COVER> TO GRADE SHALL BE MORTARED IN PLACE, NO DETERMINATION HAS BEEN MADE AS TO COMP',IANCE WITI-! DF-LDW—f;. OR 70,,IINov PEGULATiON5. OWNER. / APPL_JlCANT "S Tn, 38TAIN SUCH, DETERMINATION FROM APPROPRIATE AUTHCZ)RiTY i Ji71 'lLITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR 15 TO TO CALL, 'DIG -SAFE" AT 1--888-344-7233 AT LEAST 72 HOURS PRIOR COMMENCING WORK ON SITE, CONTRACTOR !S TO 'VERIFY GRADES AND ELEVATIONS AS WE_LL AS SITE CCINDITIONSPRIOR TO COMMENCING 'WORK ON SITE. ANY VARIATION iS TO BE BROUGHIT TO THE ATTENTION OF THE DESIGN 'E'NCANEEP !MMEDIATELY. ' 8 PARCEL IS !1N FLOOD ZONE NE LOT !S SHOWN �'N ASSESSORS MAP __9AS PARCEL - 147 11. ALL UNSUiTABL MATER'IAL SHALL BE REMOVED FROM UNDER AND \A. �'l KRA.57rl/ S L. FOR A MINIMUM iOF 5' AROUND SOh. ABSORPr*N SYSTEM AND BE REPLACED WITH MATERIAL AS SPECIFIED IN 310 CMR 15.255:0). THE INSTALLER IS TO VE THE ENGINEER A MINIMUM CIF 48 HOURS (2 WORKING DA"t) NOrRX FOR THE FINAL INSPECTION (NuMBER BELOW), ELEVI 110-1 1 S.'70- 4 HIGH CAPAGJ1NI'll-TRATOR� WTH i STONE IN AN I 1{` x 36' X I Cr TRENCH FORMATION SaL ABSORPTION SYSTEM (SAS) BUOYANCY CALCULA11ONS: ,5 00 GALLON SEPTIC TANK (I­j-IVj)($)I-'_'j)4Q� Vk'iGHT OF WATER DISPLACED 10.174-ow<11.0-6.66)x"o 17,213 LB& tkiGHT OF 'ANF PER MA.NtJFACT,,QFP. 11,&13 LEM 4";IGHT OF SOIL, ON TOF EX"CESS WEIGHT TQ OFFSET FLOT'ATlt_;N 17215-(11&33+7110) 1.726 L13& 10 20 60 bo no SOIL TEST DATE OF' SOIL TE<'T I P I SOIL TEST DONE BY R JRG ENff@t�G WilTNESSED BY OBSERVATION HOLE 1 ELEV, La DEP'I-H HOR TEXTURE COL OTHER 10/A UO AM Y SAND If G Yr- 3, /_2 N IROOTS Y , I - 111-30" 8 AM SAND 1 OYR 5/6 ROO I'S MEDIUM $AND 8 WATER ENCOUNTERED AT 5-' ELEV. - 4�6 OBSERVATION HOLE 2 ELEV.- PERCCCAT!ON RATE MiN,/iN1,H AT INCHES 1 DEPTH HOR17 TEXTURE COLOR MOTT. (OTHER 4 ROOT" 10 A 4iLOAMY SAND 110YR3/3 !NO Y 19-28- 8 JLOAMSAND - I 1 0 1 YR 5 . /6 A ROOTS L 1 28 - 1 08" c 'IM E DiUm S AN 0 2 5 '(6 / 4 WATER ENCOUNTERED AT 60" rivv, 2,7 SOIL TEST DATE OF S(.).l TEST F RUARY '0 SOIL 'TEST 004, INITNESSED OBSERVATION HOU 3 ELIE V, - __ 7;7 PERCOLATION RATE MIN,/INCH. AT 60 INCHES Ep iH _HORIZ TEXT -IRE COLOR MOTTOTHER FILL 213- 25" Ab LOAMY SAND 1()IfP4/i No 8 LOAM SAND 41-64" C MEDIUM SANG 2>5Y7/4 WATER ENCOONTERED Af —M-1- ELEV 2;0 OBSERVATION HOLE 4 ELEV._ 7.2 0':' P TFl HOI (7;j ER 0-.8" iLOAMY SAND loyp� If A 0 ROOTS 8 L 0 A M Y SAND I I OYR6/4 9-84" JC _iME66M �13ANo 12,5'r 7/4 WATER ENC(XJNlT:RED AT srLEv. 2.2 DESIGN CALCULATIONS 14UMHER or BEDROOMS 3 TOTAl- ESTIMATED FLOW ( 110 GAL/W/DAY X -_A_ 9R.) GAL. /DA'T REOUIREC, SEPTIC TANK CAPAC t," 1AM GAL, ACTUAL SIZE OF SEPTIC TANK, GAL SCAL CLASSIFICATION DESIGN PERCOLATION RATE 5-JIL MIN, /IN EFFLUENT LOADING, RATE GAL, DA)'., L 'HING AREA %Q T EAC J& 0lX36)+(47X=0/12) LFACHINC CAPACIT's' fAREA X PATE') 474,33 X 06 74 AN1.90 GAL, /DAY' RESERVE LEACHtNG CAPACiTy AMM GAL /DA'i' APPRO VED: BOARD OF HEALTH DATE A, CEN r VEST.__ YARMOM MASS, PROK`XOSED SEPTIC DriolIGN FOR S n. 1 L r -0 vi P trmmm N BCKl vKERTON rl L A% 0`122 EXETER 71"AD, LOT it) z LLJ W T YARMOUTK MASS Lwus s I slZR ANGDOMRM EXE -1 Ep r I 2203 SETIUCIeFT ROAD 508-- P. O. BOX 713 5 - f) 9,,) SOUTH DENNIS, MASS. c c, 2 c� r SCALE ATE 22 D7 E19- , '02_ _J M A R. 3 0, 20 122 1 p asp 6 FOP OF FOUNDATION .LEV. - LAB ELEV. _ w CO VEER 4' SCHEDULE 40 PVC PIPE 7/MIN. PITCH 1/8" PER FT. 4' CAST IRON PIPE FH EQUAL) MINIMUM IRI FT IT. ELEV. _ / "-TMIN. q� V. _ -=I --{ L.�& J I BGA E ELEV. E1 a 8 SUMP ELEV. _ ELEV.. ELEV, TO BE WATER TESTED 14 INCHES = J OUTLET (TO BE PLACED ON FIRM BASE) IF MORE THAN ONE OUTLET 19 INCHES ,j�: (TO BE PLACED ON FIRM BASE) 24 INCHES 29 INCHES SEP 3/4' TO 1 1/2' CLEAN - 34 INCHES (H-10)(MONO) DOUBLE WASHED STONE FREE OF FINES & SILT SEWAGE DISPOoSAo SYSTEM PROFILE WLUAAI h MAUREEN T. BERARDI R/CHARD T. KILROY, ,.R. R , KA7HLEEN A. BAMMAN '.r. 7.ELB Y - 7.58 LOT 16 14,131.4_ -6 S.F. k)� ��`p \1500Ga10 \ `� PTIC LANK `i ` 7.1 9�F . 7.27D. 0 �\ OX o. SOIL MAL �� vK� _ \T�EST 4 EL- L62 (Ilan � 7.19 � -8.62 8.54 Uk�47 OF 5' SOILS REMOVAL_ EXISTING SPOT ELEVATION 000 EXISTING CONTOUR----00---- FINAL SPOT ELEVATION FINAL CONTOUR SOIL TEST LOCATION UTILITY POLE TOWN WATER -W CATCH BASIN \NJ GAS LINE C� CLEANOUT n MI C.P. l 1 7.67 KRIS77N CALLAHAN 8.70 °r AO 4. 41 � DL 1 09.01 NfxTRATOR AS DRYKU CLEAN SAND INSPECTION PORT LOAM AND SEED 27 LAYER OF WWASHED WSTONE TNOT REQUIRED HIGH CAP STOTMNE INLATNATORS WITH i TRENCH FORMATION SOIL ABSORPTION: SYSTEM (SAS) USGS PROBABLE WATER TABLE ELEV. OBSERVED WA BOTTOM OF TEST2HOLE ELEV. _ £FFREY M. & MEGHAN MORGAN ELEV. _ WELL ZONE INDEX EL.EV _ ADJUST- WELL - ZONE , INDEX ADJUST 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TE 5 AND THE SUBSURFACE DISPOSAL OFSEWAGE. SAND GULATIONS FOR THE 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6' OF FINISHED GRADE 3.ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF OTIFT. OFDDRIVESNG IORLOADING PARKNG AREAS M 20 LOADINTHEY ARE G SHALL BOR E USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4, ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. WITH 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCEITTO DEEDED OR ZONING REGULATIONS. OWNER / OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6.UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL 'DIG -SAFE' AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. 8, PARCEL IS IN FLOOD ZONE AS PARCEL 9. LOT IS SHOWN ON ASSESSORS MAP 10. ALL UNSUITABLE MATERIAL SHALL BE REMOVED FROM UNDER AND A. D. KRAS7EV S L. FOR A MINIMUM OF 5' AROUND SOIL ABSORPTION SYSTEM AND BE REPLACED WITH MATERIAL AS SPECIFIED IN 310 Ck1R 15.255:(3). 11. THE INSTALLER IS TO GIVE THE ENGINEER A MINIMUM OF 48 HOURS (2 WORKING DAYS) NOTICE FOR THE FINAL INSPECTION (NUMBER BELOW). \ BuOyAl 11,,LCULATIONS: 1500 GALLON SEPTIC TANK (H-10)(MONO) WEIGHT OF WATER DISPLACED WEIGHT OF TANK PER MANUFACTURER4,.a ` WEIGHT OF SOIL ON TOP EXCESS WEIGHT TO OFFSET FLOTATION„M1, 10 20 40 60 80 o - WEST DATE OP SUIL MW SW ENGINEERING SOIL TEST DONE 13Y S WITNESSED BY aN OBSERVATION HOLE 1,ELEV.= a.1 DEPTH HORIZ TEXTURE COLOR MOTT. OTHER RROOTS 0-11' O/A LOAMY SAND tOYR3/2 NO it-30' B LOAMY SAND 10YR5/6 TS 30-120' C MEDIUM SAND 7.5YR5/8 WATER ENCOUNTERED AT 54' ELEV. - 4.6 OBSERVATION HOLE ELEV.= 7.7 PERCOLATION RATE MIN./1NCH AT 48 INCHES DEPTH HORIZ TEXTURE COLOR I MOTT, 10YR3/3 NO JOTHER IROOTS 0-9' JA ILOAMY SAND I10YR5/6 I IROOTS 19-48' IB ILOAMY SAND 1tOB�CIMEDIUM SAND 128 108 IC IMEDIUM SAND 125Y6/4 I I WATER ENCOUNTERED AT 60 ELEV. = 27 DATE OF SOIL TEST sRRUAR� Y 2022 SOIL TEST DONE BY SWFFTSER ENGINEERING WITNESSED BY v aENAUD t BSERVATION HOLE ELEV.- 7.7 PERCOLATION RATE MIN./INCH AT 60 INCHES DEP1H HORIZ TEXTURE COLOR MOTT. OTHER ASPHALT SHINGLE 123-25' IAb ILOAMY SAND 110YR4/1 !No I I 125-41' IB ILOAMY SAND 110YR6/6 I I I41 64 IC IMEDIUM SAND 125Y7/4 I I WATER ENCOUNTERED AT 68 ELEV. = 2.0 ELEV.= 7.2 DEPTH HORIZ TEXTURE COLOR MOTT. 10YR4/1 NO OTHER ROOTS 0-8' A LOAMY SAND B-19' B LOAMY SAND 10YR6/4 19-ac C MEDIUM SAND 25Y7/4 WATER ENCOUNTERED AT 60ELEV. = 2.2 CALCULATION NUMBER OF BEDROOMS GARBAGE DISPOSAL UNIT TOTAL ESTIMATED FLOW GAL/DAY REQUIRED SEPTIC TANK CAPACITY GAL GAL ACTUAL SIZE OF SEPTIC TANK SOIL CLASSIFICATION DESIGN PERCOLATION RATE <_ MIN./IN. 0.74 GAL/DAY/S.F. EFFLUENT LOADING RATE SQ. FT LEACHING AREA LEACHING CAPACITY (AREA X RATE) GAL./DAY RESERVE LEACHING CAPACITY GAL/DAY APPROVED: BOARD OF HEALTH DATE AGENT PROPOSED SEPTIC DESIGN FOR STEPHEN BICKERTON LOc 22 EXETER ROAD, LOT 16 WEST YARMOUTH MASS. SWEETSER ENGINEERING 203 SETUCKET ROAD 508- P. 0. BOX 713 385-6900 SOUTH DENNIS, MASS. 02660 DATE FEB. 7, 2022 = 20' JOB N0. 4654--00 LOCATION MAP REV. SHEET 1 OF 1 GENERAL NOTES 1. GASKET OR WEATHERSTRIPPING AND INSULATION, EQUIVALENT TO THE IINSULATI❑N ON THE SURROUNDING SURFACES, IS TO BE INSTALLED UPON COMPLETION OF THE SET-UP OF THE HOME AT CEILING ACCESS PANELS AND / OR PULL DOWN STAIRS ON SITE BY (BUILDER, 2 DRYER VENT DUCT SHALL TERMINATE ON AN ❑UTSIDE WALL OF A BUILDING NOT LESS THAN 3'-0" IN ANY DIRECTION FROM ANY OPENING INTO THE BUILDING AND MUST BE EQUIPPED WITH A BACKDRAFT DAMPER. 3 'TUB / SHOWER CONTROL VALVES TO HAVE A HIGH STOP LIMIT SET TO LIMIT WATER TEMPERATURE TO A MAXIMUM OF 120' F (49°C). 4 THE BASEMENT AND / OR ATTIC DOOR MUST HAVE WEATHERSTRIPPING AND A (SWEEP PROVIDED AND INSTALLED ON -SITE BY BUILDER. 5. THIS HOUSE IS OVER 6'-0' FROM THE LOT LINE ON ALL SIDES, 6 'DUCT TIGHTNESS AND BLOWER DOOR TESTING WILL BE COMPLETED, ❑N-SITE BY BUILDER, BY A QUALIFIED PROFESSI❑NAL CERTIFIED BY MA, 7. A 48 HOUR NOTIFICATION IS REQUIRED PRIOR TO THE SET, THE CSL OF RECORD WILL RELAY THIS TO THE LOCAL BUILDING AUTHORITY. IF ANY C❑NNECTI❑NS HAVE BEEN CONCEALED PRIOR TO THE INSPECTION, THE BUILDING OFFICIAL MAY REQUEST HAVING THE REMOVAL OF ELEMENTS THAT CONCEAL THE C❑NNECTI❑NS TO PR❑VIDE ACCESS, THIS WOULD NOT CONSTITUTE "DESTRUCTIVE DISASSEMBLY", ALL CONNECTIONS ❑N-SITE MUST BE INSPECTED BY THE LOCAL AUTHORITY, 8 ADD BLOCKING IN WALLS ON ALL ENDS OF CABINET RUNS FOR BASE, WALL, TALL AND VANITY CABINETS TO PULL SIDE OF CABINETS TIGHT TO THE WALL. 2015 IRC NOTES 1. WINDOW EGRESS REQUIREMENTS MEET 2015 IRC, SECTION R3101 2. VISUAL INSPECTION OF THE INSULATION INSTALLATION WILL BE DOCUMENTED BY THE APEX QC DEPARTMENT, 3, BUILDER TO INSTALL A FRESH AIR INTAKE FROM THE ON -SITE FORCED AIR SYSTEM TO MEET THE REQUIREMENTS OF M1507.3.3(L). 4, HOT WATER PIPE INSULATION SHALL BE INSTALLED IN ACCORDANCE W/ SECT. Nl103.4.2 OF THE 2015 IRC. 5. EXTERIOR WALL FIRE RATING AND REQUIRED FIRE SEPARATION DISTANCES MEET THE REQUIREMENTS PER THE 2015 IRC TABLE 302.10) & (2) 6. BUILDER TO PROVIDE AND INSTALL HIGH -EFFICACY LAMPS IN 75% OF PERMANENTLY INSTALLED LIGHTING FIXTURES ❑N-SITE PER SECTION N11041 7, ALL WINDOWS WITH OPENINGS WHICH OPEN 4 INCHES OR GREATER, ARE 72 INCHES ABOVE THE FINISHED GRADE OR SURFACE BELOW AND THE LOWEST PART OF THE CLEAR ❑PENING IS LESS THAN 24 INCHES ABOVE THE FINISHED FLOOR, WILL REQUIRE WINDOW GUARDS PER 2015 IRC SECTIONS' R312,2, THE WINDOW GUARDS WILL BE PROVIDED AND INSTALLED ON -SITE BY BUILDER. 8. BUILDER TO INSTALL A WHOLE HOUSE VENTILATION SYSTEM TO MEET THE REQUIREMENTS OF TABLE R403,5.1 PFS Corporation Northeast Region APPROVED Michelle Baker 02/22/2022 Approval limited to Factory Built Portion OF RYAN W. BORING CIVIL NO.49506 O STEMIN SN-11884/QN-17596/JN-7�2304/MR ELECTRICAL NOTES x 2020 NEC NOTES L ALL LIGHT BOXES MUST BE RATED TOSUPPORT 50# FOR NON -PADDLE FANS AND 70# FOR PADDLE FAN BOXES, 2, TAMPER RESISTANT ( T.R. ) RECEPTACLES REQUIRED THRU-OUT THE ENTIRE HOME, UNLESS NOTED OTHERWISE ON THE PLAN, 3. ALL BALCONIES, DECKS AND PORCHES ACCESSIBLE FROM INSIDE THE DWELLING UNIT ARE REQUIRED TO HAVE ONE WATERPROOF ( W.P. ) T.R. GFI RECEPTACLE WITHIN THE PERIMETER OF THE BALCONY, DECK OR PORCH, 4. 1 & 2 FAMILY DWELLINGS ARE REQUIRED TO BE PROVIDED WITH ONE W.P. T.R. GFI RECEPTACLE ACCESSIBLE WHILE STANDING AT GRADE LEVEL LOCATED A MAX. OF 6'-6" ABOVE GRADE AT THE FRONT AND REAR OF EACH DWELLING UNIT. 5. THE GROUNDING CIRCUIT CONDUCTOR FOR THE CONTROLLED LIGHTING CIRCUIT SHALL BE PROVIDED AT THE LOCATION WHERE SWITCHES CONTROLLING LIGHTING LOADS THAT ARE SUPPLIED BY A GROUNDED GENERAL PURPOSE BRANCH CIRCUIT FOR OTHER THAN THE FOLLOWING A. WHERE CONDUCTORS ENTER THE BOX ENCL❑SING THE SWITCH THROUGH A RACEWAY, PROVIDED THAT THE RACEWAY IS LARGE ENOUGH FOR ALL CONDUCTORS, INCLUDING A GROUNDED CONDUCTOR B, WHERE THE BOX ENCL❑SING THE SWITCH IS ACCESSIBLE FOR THE INSTALLATION OF AN ADDITI❑NAL OR REPLACEMENT CABLE WITHOUT REMOVING FINISH MATERIALS C, WHERE SNAP SWITCHES WITH INTEGRAL ENCLOSURES COMPLY WITH 30015 (E) D, WHERE A SWITCH DOES NOT SERVE A HABITABLE ROOM OR BATHROOM E. WHERE MULTIPLE SWITCH LOCATIONS CONTROL THE SAME LIGHTING LOAD SUCH THAT THE ENTIRE FLOOR AREA OF THE ROOM OR SPACE IS VISIBLE FROM THE SINGLE OR COMBINED SWITCH L❑CATIONS F. WHERE LIGHTING IN THE AREA IS CONTROLLED BY AUTOMATIC MEANS G. WHERE A SWITCH CONTROLS A RECEPTACLE LOADS 6, ALL 15 AND 20 AMPERE 125 AND 250 VOLT RECEPTACLES INSTALLED IN A WET LOCATION STILL MUST HAVE AN ENCLOSURE AND COVERS THAT ARE WEATHERPROOF WHETHER AN ATTACHMENT PLUG CAP IS INSERTED OR NOT. ALL ENCLOSURES AND COVERS INSTALLED IN WET L❑CATIONS MUST BE LISTED AS "EXTRA DUTY" 7. A LUMINARIES WEIGHING MORE THAN 50 LBS. SHALL BE SUPPORTED INDEPENDENTLY OF THE OUTLET BOX, UNLESS IT IS LISTED AND MARKED FOR THE MAXIMUM WEIGHT TO BE SUPPORTED, 8. ALL 120 VOLT, SINGLE-PHASE, 15 AND 20 AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS OR DEVICES INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS BEDROOMS, SUN ROOMS RECREATION ROOMS CLOSETS, HALLWAYS, LAUNDRY AREA, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED COMBINATION -TYPE ARC -FAULT CIRCUIT INTERRUPTER INSTALLED TO PR❑VIDE PROTECTION OF THE ENTIRE BRANCH CIRCUIT. 9. ALL BATHROOM RECEPTACLES, LAUNDRY RECEPTACLES, EXTERIOR RECEPTACLES AND ALL RECEPTACLES SERVING KITCHEN COUNTERTOPS, THE DISHWASHER CIRCUIT OR RECEPTACLES THAT ARE WITH IN 6'-0" OF THE ❑UTSIDE EDGE OF THE KITCHEN SINK INCLUDING RECEPTACLES UNDER THE SINK OR IN CABINETS ARE REQUIRED TO BE GFI PROTECTED. eb 22, 2022 T U m z L' <L Z ED O H- H- (� CK � LLJ C__) U `D CO CU V m LL I v :57: cn O �v Pa �qV CD Q Z M W Z <[ Qz� D Q Q z > Q o D V Z= LLJ w w v :�o J CL o w } QM Q o0 v El LLJ 3 � N CL � o o M x Q Y (U N N N Q � N N � J cws v > D Q ALL SN-11884/QN-17596/JN-72304/MA DWR SCHEDULE KEY OPENING TYPE ROUGH OPENING MANU. "L" ( 'V' I "R" I"S,F.- AIR "U" DESCRIPTION A 3068 36' INSUL. CORE 38 1/2" x 82 1/2" THERMA-TRU 0 194 7.14 22.06 .10 14 6 PANEL A 3068 36" INSUL. CORE 38 1/2" x 82 1/2' THERMA-TRU 5.1 17.2 4,00 1977, .10 .25 1/2 GLASS G 1668 INTER27R PASSAGE 20 1/4' x 82 1/2' CRAFTMASTERI N/A N/A N/A I N/A N/A N/A I 2668 INTERIOR PASSAGE 32 1/4' x 82 1/2' CRAFTMASTER N/A N/A N/A N/A N/A N/A Q 6068 6-0' SLIDING PATIO 72' x 80" M. W 30.8 15,28 3,03 40,0 .09 .33 FULL GLASS 72' x 80' ANDERSEN 2378 14.72 333 39.34 .03 .30 72 1/8' x 80 1/21,1 SILVERLINE 23.78 14.72 3,23 40.31 .03 .31 M W BRTCKMCULD WINDOW SCHEDULE "U" VALUES DP RATING KEY TYPE CODE ROUGH OPENING "L" "V" "SQ,FT.'I "R" AIR SHGC STANDARD WITH ARGON L DOUBLE HUNG 24210 30 3/8"x37 5/8" 4.9 2.391 7.94 3 4 1 .11 .28 .29 50 SP DOUBLE HUNG 1846 22 3/8'x57 5/8' 57 2.9 8,95 3.4 ,11 .28 .29 so 3. DOUBLE HUNG 3046' 38 3/8'x57 5/8' 10.8 113.4 576 15,36 3.4 .11 .28 29 50 17, DOUBI E HUNG 3056' 38 3/8"x69 5/8" 6.94 18 55 3.4 .11 .28 .29 50 PFS Corporation Northeast Region APPROVED Michelle Baker 02/22/2022 Approval limited to Factory Built Portion OF A44 RYAN W. BORING CIVIL NO.49506 ��G/STERN eb 22, 2022 SN-11884/QN-17596/JN72304/MA R, S =R aY VARY FROM ELEVATI❑N ❑N-SITE BY BUILDER PFS Corporation Northeast Region APPROVED Michelle Baker 02/22/2022 Approval limited to Factory Built Portion vv{S'S\ 9�, yG N RYAN W. BORING m+ CIVIL NO.491506 O n\C' / ST E�� 22, 2022 0 U z� z z � c L z o w o � J L-i U W q J J U 11 nn W1 (� n W CC) o \ VI I/ V o _ Ci Q L S2 w Q qv o M 2 z ¢ } Q Z J D Q O > > <E D U �a S L_ g � J o� NZ J LLJ X ¢ Q ~ O (U Z (UW Q 2� �3m v� o � MMM - MAIN SEWER r--------------i EMERGENCY DISCGN IF AS PER .Il IN IA 13 . TO BE PROVIDED AUD INSTALLED Du -SITE BY BUILDER , pN0 IS ip BE APPRGVEO III tHE , L— LGC-L BUILDING 1-S=E[TOR.--, S \\ Lt�l U T L C D 3 1:J6� J ELEC I I PANEL-- G--- I _ -� 13 is]I] • cr[ �,W tH]�J 14 o-, I i I ry HI ASF-------- o .]Iry BRACING --- — — I �l __J i � r_ -J n -- -- I' ILuI r L----- C° =_J______ J IF i I I 1 GFI I I 1��3Ts III 7 G I Ill�b F 1 L HacE[uNc GGR RADpN PGW' I I �T-STnT ---WLRF— I LIUJ�E F.. I — I^ I [m of I I I `^ F J I Ids i�� i -- III ET L_______________° i I r ID I'- le zz I I I x m ® --J L---1 I b nxry N AND BLOC%={TOVA�iE _____, i L T- I I N6 TVSF I I `OX OR PADDLE FAN 20 MLY j I � [JBG% IN FGR I BRACING I L L___IC-J —__ T . GF[ RECEPT 2 2]' I I I ASF Axn BLOC% FOR PADDLE FAN 66• * S} m ASF BRACING 1 1 BRACI iV H BRACING--_143___J I 1 BB%AVD RO[N CJ rl I FMPADDLE FAN ' e Bp%AND AL-,i L—_--___—_ I FDR PADDLE FAN I I I I I I I I 1 r�'IwE --- IL- - - L-------"-3----- iiFSS I Illr� I I J 0 J I .mTi,g I---------------------------------- I i .________________________________--__________----_ VP VP Gfi GFI __----_—__—@ GFT �___ __-z___-_----___-z__--______ M_______________®_-_ NOTES: 1, ALL LIVING SPACES ARE ARC -FAULT PROTECTED C❑MBINATI❑N TYPE 2. SEE 2020 NEC N❑TE 3. 4, SN-11884/QN-17596/JN-72304/`A, PFS Corporation Northeast Region APPROVED Michelle Baker 02/22/2022 Approval limited to Factory Built Portion OF A4g3S�� yG O U RYAN W. BORING 1 L) CIVIL NO.49506 �Oc �FV / STERN FS L eb 22, 2022 L � z Q ��-o CL u LLl z o W d f- LJJ U 0 U C ~ LLI U J Li VDU CD MQ f- Q�� D Q ¢ z > -) u Q -) U � S LLI F -j C w Q m X Q Q C, Z d o ~ cu z J 0j U V S I I I I I SN-11884/QN-17596/JN72304/MP {� B'-1o• 2'-3 1/2• 2 -3 1/2' 35-9 1/2' 4"-3' 21-4 1/2' ------------------------------------------------------ F- - I --- 979 T.L. C) PLF) i ---� --------------------------- ----z I I I I *BUILDER'S RA/PE TO DESIGN FOUNDATION TO THE LOADS LISTED. APPROVED AND INSPECTED BY THE LOCAL I I I AHJ* *REQUIRED FLOOD VENTS BY FOUNDATION DESIGNER* 13-3' 768 T.L. (PLF) 32'-6• 768 T.L. (PLF) 12'-4' 768 T.L. (PLF) 7'-11' 1044 T.L. C I I 6'-7 1/2" 6'-7 1/2• 8'-3' 8'-3• eJ�ck atEz ftoa E—L sa E e'-3' 7'-9' 6'-2' I I 3'-11 1/2' 3'-l1 li2 ;POINT I L D A D I I 2644u L—J L—J L—J 6q. L—J L__`_J L_J L_J L—J L_J PLAINT I t/ 6^ POINT LOAD PAINT LD.4D I LOAD 94638 UG. l]ei ER F EO9390q 25744 *NOTE: GIRDER SPLICES MUST FALL OVER PIERS. j I. T.L. CPLF) FOUNDATION ACCESS PROVIDED AND I INSTALLED ON -SITE BY BUILDER AND IS I L- — — — — — — — J I 849 T.L. <PLF) -J' L-------- ---� T0BEAPPROVED BYLOCAL AHJ -------------� r-------- I I I I I I I I I 979 T.L. CPLF> B" MINIMUM CONCRETE WALLS I I L ------------------ - - - - - ----_ _----_-J - I Aso Sina Stu --------------- l 1/2' iez9waftJ I I I - ---- ---- SiHOt<RJ i8191/2" I I I I I L----- I I I -------J 66'-C• FFOUNDATION DRAWINGS ARE TO BE USED AS A GUIDE ONLY. APEX HOMES WILL NOT ACCEPT ANY LIABILITY OR RESPONSIBILITY FOR INCORRECT FOUNDATIONS. N❑TES 6 MAX ANCHOR BOLT SPACING 6'-0' O.C. (4'-0" O.C. MAX IN AREAS WHERE WIND VELOCITY 1. FOR ADDITIONAL INF❑RMATION SEE TYPICAL FOUNDATION DRAWING A15,16 OF THIS SET IS @ OR EXCEEDS 100 MPH) 2, PERIMETER RAIL ATTACHED TO SILL WITH 166 NAILS AT 6" ❑,C. 7. WINDOWS OR VENTS (INSTALLED BY BUILDER) ARE REQUIRED TO PROVIDE 1/150 OF FLOOR 3, PIER F❑OTINGS BASED UPON 2000 PSF ALLOWABLE SOIL BEARING PRESSURE AREA AS FREE VENTILATI❑N AND SHALL BE LOCATED AS CLOSE TO CORNERS AS P❑SSIBLE 4, CONCRETE COMPRESSIVE STRENGTH 2500 PSI 8, NOTES ❑N THIS PAGE TAKE PRECEDENCE OVER NOTES ON TYPICAL FOUNDATION DWG, 5. M OR S TYPE MORTAR TO BE USED A15/A16 PFS Corporation Northeast Region APPROVE® Michelle Baker 02/22/2022 Approval limited to Factory Built Portion N OF RYAN W. BORING o U CIVIL NO.49506 O POc �FG/STE�F4 FS L ENG\ eb 22, 2022 z 0 W C� W iE ED T i z Q Q W J CL L T 0 � z z z Un 77 z E:1 o � Q o C) z o Q 0 CU m F- <L J Q z � L) 7L) zT Li LJ , LJ X Q Q LJ s U L z �3� NL_ jO ACD r; N TE TO BUILDER SEE THE FOLLOWING PAGES FOR A OD TIGNAL ON-STE FASTENING REQUIREMENTS A9-A32, A15 — inneterI] 9nge. l5/8'lon 0.092'dg, 19/64'hena; u.uyM- tl. 13/B.Og nnn�lnr-ringed; 6tl .I. inne ter, 1]/8"long, l/4?Hectl; nor gypsun boortl nail, D09I5' dinrrter, 1l/B'long I9/6a'Fentl. ➢BL 2X6 TOP FLAi— R-2I FIBERGLASS- . INSULATION WITH PPCR BARRIER EX EU)T.G- 4/4 VINYL 2x6 STUDS EXT. SHEATHING — I— O.S.B. CST. 2x6 BGTTDM ?LATE - TOP SILL PLATE TOP O l BT AP BY BUILDER J GRADE TO SILL PER LREQUIREMENTS 1/2, 2' " ➢IA IS'. EMBEDMENT ANCHOR BOLTS 12• MIN. FROM EACH CORNER AMC TW O.C. MAX. THEREAFTER. (MIN. OF WD PER SILL PLATE) 10' CONCRETE MASONRY UNITS OR PDURE➢ CONCRETE WALLS PARGING COVERED VITN BITL.D.- PE FOR ➢RPIN PROUND FOOTING PERIMETER IN STONE BEB MIN. 204 10• CONTINUOUS CONCRETE FOOTING L EDIII NGS SMALL BEAR ON SOUND, UNDISTURBED, VIRGIN EARTH AND SHALL BE INS TPLLED BELOW LOCAL FROST LINE. DESIGN BEARING CAPACITY OF SGIL IS 2000 PSI 2➢V/ ➢BLTOP PLATE :ULATIDN V/ V.B. PER AL RES-CHECK aS LATIGN TO BE PROVIDED AND _➢ BY BUILDER 2.4 BOTTOM PLATE, 2L 0 SPf kZ FLOOR JD IST B 16' OL. x fOI . T 6` n vn OC4nnN WALL DN-slrE BY aLnR MINIMUM 6 MIL. POLY BARRIER OVER 4" 28 STGNE BE➢ I6'xl6' BLOCK PIER CRAWL SPACE FOUN: ON -SITE By BUILN CGHTINUDUS RIDGE VENT (END PLUGS AND CONNECTORS INCLUDE" 3' MIN. VENT STACK WATER TIGh'- WATER TIGHT— STACK TO EXTEND 12' MIN. BELOW ROOF LINE AND BE WATER TIGHT THRU ROOF PLUMBING VENT THRU ROOF t] e. •�...., .._._ 9nge, u/e ;ong, ram. tlinneter. l3/B'ong, nnnumr-r ged; 6tl 4, 0.092•dnneter, I)/B'bnq, t/4ohentli nor ' bonrtl x, 0D91Gnd. NOTE: gypsum. anmet r,. t>/9•wng. 19/6a•Fe 1, VENT THRU ROOF CONNECTION TU BE CUMPLETED IN FIELD BY BLDR/CONTRACTOR. 2. NO REDUCERS ALLOWED ON STACK WITHIN 12' OF UNDERSIDE OF ROOF, DBL 2X6 TOP PLATE) tT ❑ MIT Tug 5/8• DRYWALL T❑HN)) V2' CUTSWI SHERS R-21 FIBERGLASS AT 49' OL. INSTALLED IN LAGS AT 2' • INSULATION WITH BARRIER FIELD OR 1/2' Ot, INSTALLED IN FIELD n VAPOR E%T. VI➢ING nLuwwx r alPs a/ 4 INYL IR' DRYWALL \ Ax x 2x6 STUDS �wswrlw�a+r*Le ENT. SHEATHING — 6. O.S.B STD) 6 ML. POLY. VAPOR BAR 2. LEDGER W PRESSURE _i OR JOIST HANGERS TREATED SILL PLATE UNIT TO LMR CONNECTDTN. SOLID BLOCK _F CAACE AT BOLTS WITH WASHERS (TOP COURSE) FIELD4D DC 2' LACS A IN FIELD OR 3/2' LAGS T 42' 4' GRAVEL BED D.C. INSTALLED IN FIELD L SPACE WIN TKs /I I.FILD I 2x6 BOTTOM PLATE - TOP OF SILL PLATE, BY APEX - ° BT BUILDER GRADE TO SILL PER LOCAL REQUIREMENTS "' D[P. t5' EMBEDMENT ANCHOR BOLTS 12' MIN FROM EACH CORNER AND 410' D.C. MAX. THEREAFTER. (HIM OG TWO PER SILL PLATE) J/ 10" CONCRETE MASONRY UNITS DR POURED CONCRETE WALLS PARGING COVERED WITH BITUMINOUS COAT BELOW GRADE 4- PERFORATED BRA IN AROUND FOOTING PERIMETER IN 4- 2B ST ONE BED IN. 20'x TO' CONTINUOUS CONCRETE FOOTING ALL FOOTINGS SMALL BEAR ON SOUND, UNDISTURBED. VIRGIN EARTH AND SHALL BE INSTALLED BELOW LOCAL FROST LINE. DESIGN BEARING CAPACITY OF 6DIL IS 200B PSI NOTTESN I L TERIAL TO BE SPF n2 UNLESS a'HBR--E SPECIFIED. FOR INSULATION REQUIREMENTS SEE INDIVIDUAL RES-CHECK. 2. ALL EQUIPMENT, DUCT WORK. CHIMNEY, AND EXHAUST DUCTS PROVIDED AND INSTALLED ON -SITE UNLESS SPECIF[E 0. LL VAPOR BARRIERS INSTALLED ON WINTER ARM SIDE. 4. SEE RAFTERS CONNECT DTBS IN TMIS SUBSET PER INDIVIDUAL PLAN SUBMITTAL. E. RO❑F PITCHES LESS .. a/I2 AND GREATER THAN 2/IF REQUIRE DOUBLE UNDERLaYMENT V/ ASPHALT SHINGLES. SN-11884/QN-17596/JN-72304/MA LI— \�plllllllil 2/ STLOSIo I6 E_ DEL PLATE 2-30 INSULATION W/ V.B. PER INDIVIDUAL RES-CHECK -L..R BY NS Tl6. TER E PROVIDED AND 2.4 BOTTOM PLATE. 2x10 SPF k2 FLOOR JOUST B I6' D.C. FIBERCL SS L SEALER ❑ _ PLATE W[LS R 6' O.C. ASEMENT FOUNDATION WALL ON -SITE BY BLDR. DE FOUNDATION DETAILS IN 4• POURED -1/2' SIP T SIQ C❑rvCRETE SLAB MINIMUM 6 MIL. POLY VAPOR BARRIER OVER 4" 20 STONE BED 6'x16' BLOCK PIER FORCRA. (ON ST. BYESUBLD ,ONDAiC CONTINU❑US RIOCCE VENT D (END PLUGS CONNECTOPS INCLUDED) 1 ' �i111UilIIFRi PFS Corporation Northeast Region APPROVED Michelle Baker 02/22/2022 Approval limited to Factory Built Portion OF A44 pRYAN A BORING 11 U CIVIL m NO.49506 S 4 c L eb 22, 20221 L 0 z �D zLn z �Ln Q �Q z - z z o � � V W U � J U CO V m LLl O GO`V Pq J 0- GO C:) z o z Q:� Q o= > U o� W LLI w v 2: C Z LLJ q o X¢Q z� �z .ti I L, Q S Q O O M A MA. CERTIFICATION FOR MO➢ULARS YES X NO _ THE FOLLOWING ELEMENTS OF CERTIFICATION REDU[REED BY THE MANUFACTURER TO EXCLUDE EACH HOME ARE AS FOLLOWS! I) DESIGNATED ONLY FOR ERECTION ON A SITE -BUILT PERMANENT FOUNDATION 2)NOT DESIGNED TO BE MOVED ONCE INSTALLED 3)DESIGNED AND MANUFACTURED TO COMPLY WITH NATIONALLY RECOGNIZED MODEL BUILDING CODE OR EDUIVALENT TO BUILDING LODES FOR ON -SITE HOUSING, OR WITH MINIMUM PROPERTY STANDARDS ADAPTED BY THE SECRETARY PURSUANT TO TITLE II OF THE NATIONAL HOUSING ACT, AND 4)TO THE MANUFACTURER'S KNOWLEDGE IS NOT INTENDED TO BE USED OTHER THAN ON A SITE -BUILT PERMANENT FOUNDATION, PORCH SLAB, HEADER, STEPS TO GRADE, RAILING AND POSTS ON -SITE BY BUILDER STEPS TO GRADE ON -SITE BY BUILDER SN 11884/QN-17596/JN-72304/MA OF Ma o RYAN W, BORING U CIVIL NO.49506 O POo �FGIST Ep� FS L ENO\ eb 22, 2022 PFS Corporation Northeast Region APPROVED Michelle Baker 02/22/2022 Approval limited to Factory Built Portion NOTE: ACTUAL HOUSE MAY VARY FROM ELEVATION z z � o T O u Q u _J � u z n E] � W n~// L� D D� H LIJ u o u `D MH w W z W C] q o Q U � Z } J <T Z QED Q v_ W � o w r) v� J J X¢Q�. Wry ~ c) IU Z U Q o CD r-------------------------------------------� r-------------------------------------: IMA SINGLE AND TWO FAMILY DWELLING CODE (780 CMR) 9TH EDITION I , IMPORTANT NOTE 120151L /GAS /PLUMBING CODE (248 CMR) : :ALL FLOOR COVERINGS TO BE PROVIDED BY BUILDER, j 12015 INTERNATIDNAL MECHANICAL CODE w/ MA AMENDMENTS I (THEREFORE IT IS THE BUILDERS RESPGNSIBILITY TO 1 12020 NATIONAL ELECTRICAL CODE w/ MA AMENDMENTS 1 [IDENTIFY ANY REQUIREMENTS TO APEX HOMES FOR RAISING L'2018 INTERNATIONAL ENERGY CONSERVATION CODE W/ MA AMENDMENTS' DOORS CABINETS, ETC. PRIGR TO CONSTRUCTION. _____________ _- ---J '-------_----------------- -------' GLENCO SYSTEM CALC'S1 ALL EXT. LOAD BEARING HDR'S WITH SPAN OF 5'-8' OR LESS WILL BE (3) 2x6 SPF #2 ALL OTHERS WILL BE SPECIFIED. ALL REQUIRED JACK STUDS SHOWN ARE 2x6 SPF #2. ALL M/W HDR'S: WITH SPAN OF 8'-1' OR LESS WILL BE (4) 2x6 SPF #2 ALL OTHERS WILL BE SPECIFIED. r--- 1 CONE 12' VENT STACKS REPL STD 1 1/2'j 1 VENT STACKS -PER CODE 1 l-------------------- J NOTES: 2, HEAT SYSTEM ❑N—SITE BY BUILDER 3, MW CLASSIC WIND❑WS BY PLYGEM 4. 1ST FLOOR SQUARE FOOTAGE = 1,755 SQ/FT SN-11884/G!N-1759o/JN-72304/MA r(4) Zx10 SYP #t 77o7 GIRDER l 7'-7' O.C. MAX. FLOOR LOAD ONLY l TOTAL LOAD ONLY PFS Corporation Northeast Region APPROVED Michelle Baker 02/22/2022 Approval limited to Factory Built Portion RYAN W. BORING v CIVIL NO.49506 A�O•c �FG! ST ERGO ��� 0 t eb 22, 2022 SIDING=21 1/2 SQ SHINGLES=29 SQ 5. 8'-0" 1ST FLOOR CEILING HEIGHT 10 EXT BEAM @ DINING ROOM TO BE (3) 2x10 SPF #2 6, 9/12 STORAGE RAFTER ROOF SYSTEM @ 16' ❑.C, 7. ES VERSI❑N2.0 8. CLG BEAMS @ BEDROOM #1 & #3 TO BE (2) 1 1/2"x24" M.L. (1 PER UNIT) 9. CLG BEAM @ DINING/LIVING ROOM TO BE (6) 1 1/2"x24" M.L, (3 PER UNIT) z 0 F— LLJ U W O z Q H— z Q Q Li J m Q 0 i2 Q J ED z ��u z= Ld0LJ N0- H _J X LJ y o ()J V) Z J (U CCLLJ _1 W U 2 3 as N n 0 0 ?� (y) U N N N M OJ I 0OJN IZI ATTACH STUD TO RAIL w/(2) 0.131"x3" NAILS. ATTACH RAIL TO TOP & BOTTOM CHORDS w/(2) 0131"x3" NAILS. STRAP STUD TO TOP AND BOTTOM CHORD w/SIMPSON CS22 STRAP w/(6) 0.148"x2 5" NAILS (6) 0131'x3' NAILS / 1/2'0 BOLT 10" (14) 0.131"x3" NAILS NOTES: -CONTINUOUS BRACING TO BE 2x3 (MINIMUM) OF ANY SPECIES/GRADE -FASTEN BRACING TO EACH INTERSECTING FRAMING MEMBER w/ (2) 0.131"x3" NAILS -BRACING MAY BE SUBSTITUTED WITH FULL -HEIGHT BLOCKING BETWEEN FRAMING MEMBERS OR CONTINUOUS SHEATHING -UPLIFT CALCULATIONS ARE BASED ON ALLOWABLE WIND SPEEDS. EQUIVALENT ULTIMATE WIND SPEEDS ARE 129 MPH AND 154 MPH FOR 100 MPH AND 120 MPH ALLOWABLE WIND SPEEDS, RESPECTIVELY ATTACH RAIL TO TOP CHORD w/(2) 0.131"x3" NAILS, ATTACH RAIL TO RAIL w/(l) 0.131'x3' NAILS. STRAP ACROSS RIDGE w/SIMPSON CS22 STRAP w/(2) 0.148"x2.5" NAILS ATTACH RAIL TO TOP CHORD w/(2) JaF 0.131'x3' NAILS. ATTACH RAIL TO RAIL w/(2) 0.131"x3" NAILS. LAP SHEATHING ACROS�CHORDSw/0) 013FLIND1" 3 TNAILSACH TRUSS 2x6 SPF #2 @ 16' O.C. 0 (7) 0.131"x3" NAILS +/0 �. SAT I 46 _ �C QN 1759o/JN-72304/MA PFS Corporation Northeast Region APPROVED Michelle Baker 02/22/2022 Approval limited to Factory Built Portion v° r LAP SHEATHING 2' EACH SIDE RYANWBORING w/(9) 0.131"x3" NAILS EACH END o CIIL �/ Cd 14'-6' NO.49506 7 3" 7 3 'O �O SOT �FG/STER CON 4B 2x10 SPF #2 @ 16' O.C. FS L E G� N � Rv- 3 Rv=568# - Ru=-2 13'8 1/2" Ru=-2# 13'-8 1/2" eb 22, 2022 27'- 6" N Q z z� z �_ � W z O Q E-1 3 E D-/ 'J \ H o M C V J n W Q O� Z o M J Q z ��o v Q U 2 W wows J F- J Z LLJ ^� o C- XQ Q W Z d o (U ~ Z U W Q Z L a o m Y a N A1) ATTACH STUD TO RAIL w/(2) 0.131'x3' NAILS, ATTACH RAIL TO TOP & BOTTOM CHORDS w/(2) 0.131'x3" NAILS. STRAP STUD TO TOP AND BOTTOM CHORD w/SIMPSON CS22 STRAP w/(4) 0.148"x2.5" NAILS 10 Rv=748# Ru=-146# - QN-17596/JN-72304/MA Q ATTACH RAIL TO TOP CHORD w/(1) d 0.131'x3' NAILS. ATTACH RAIL TO RAIL w/(1) 0.131'x3" NAILS. LAP SHEATHING ACROSS FLIP AND ATTACH EACH TRUSS 2x4 SPF #2 CHORD w/(2) 0131"x3" NAILS (5) OA31'x3' NAILS 1/2"0 BOLT (9) 0.131'x3" NAILS NOTES: -CONTINUOUS BRACING TO BE 2x3 (MINIMUM) OF ANY SPECIES/GRADE -FASTEN BRACING TO EACH INTERSECTING FRAMING MEMBER w/ (2) 0.131' 3' NAILS -BRACING MAY BE SUBSTITUTED WITH FULL -HEIGHT BLOCKING BETWEEN FRAMING MEMBERS OR CONTINUOUS SHEATHING -UPLIFT CALCULATIONS ARE BASED ON ALLOWABLE WIND SPEEDS. EQUIVALENT ULTIMATE WIND�SPEEDS ARE 129 MPH AND 154 MPH FOR 100 MPH AND 120 MPH ALLOWABLE WI D SPEEDS, RESPECTIVELY 2x10 SPF #2 2 16' O.C. 13`9 1/2" 7'- ATTACH RAIL TO TOP CHORD w/(3) 0.131"x3" NAILS. ATTACH RAIL TO RAIL w/(2) 0.131'x3' NAILS. STRAP ACROSS RIDGE w/SIMPSON CS22 STRAP w/(3) 0.148"x2.5" NAILS I +I 0 12 I I6s�C �9 LAP SHEATHING 2' EACH SIDE w/(6) 0A31'x3" NAILS EACH END 9'-6" 2'-3' Rv=582# Ru=-120# 22'-G" ATTACH RAIL TO TOP CHORD w/(1) 0.131'x3' NAILS. ATTACH RAIL TO RAIL w/m 0,131'x3' NAILS. LAP SHEATHING ACROSS FLIP AND ATTACH EACH TRUSS CHORD w/(2) 0131'x3" NAILS c'+I O� A� (@ I69 8'-8 1/2' z L) 'OD, 0 z a C CU N 1 n L) W F-'-I 0 COW \ Cd V M LW lco r� z `zo o Q M a- � Ellq� z o Q � ar � <E Q > (� o U = Q � � LL1 LLI W W V _j W�� ao X¢Q ?v w — �z o �3 a PFS Corporation aIIIo c, Northeast Region c APPROVED m Michelle Baker 02/22/2022 _ N Approval limited to Factory Built Portion o N W OF mqSS O N a RYAN W. BORING _4 O CIVIL U cn p� N0.49506 0 SOT �FG I ST�R� y cy o �yo eb 22, 2022 w o 010 �1 II'-0 3/16' 2'-1 3/4' Cyq SPF 3 #2 IOI t, UK, I ./(I) @ I D'C' #BTT TOE SCREWS OR (I) SIMPSON LTP4 2.4 SPF #2 @ 16' O.C. PORCH HEADERS DESIGNED FOR 240 PLF GRAVITY 6'-0' IO' AND 203 PLF UPLIFT BOTTOM SIMPSON CHORD TO RAIL w/(I) A34 ANGLE OR (4) BOTTOM CHORD TO HEADERS 0.131'x3' NAILS TOED. RAIL AND w/(3) #8x3' TOE SCREWS LE➢GER TO TRUSS w/0.131'x3' OR (1) SIMPSON H2.5A NAILS @ 3' D.C. NOTES: —CONTINUOUS BRACING TO BE 2x3 (MINIMUM) OF ANY SPECIES/GRADE —FASTEN BRACING TO EACH INTERSECTING FRAMING MEMBER w/ (2) 0.131 "x3" NAILS —BRACING MAY BE SUBSTITUTED WITH FULL —HEIGHT BLOCKING BETWEEN FRAMING MEMBERS OR CONTINUOUS SHEATHING —UPLIFT CALCULATIONS ARE BASED ON ALLOWABLE WIND SPEEDS. EQUIVALENT ULTIMATE WIND SPEEDS ARE 129 MPH AND 154 MPH FOR 100 MPH AND 120 MPH ALLOWABLE WIND SPEEDS, RESPECTIVELY w/(5) #8x3' TOE SCREWS AND RAIL TO EACH TRUSS W/(5) #8x3' SCREWS UN-17596/JN-72304/MA PFS Corporation Northeast Region APPROVED Michelle Baker 02/22/2022 Approval limited to Factory Built Portion OF _' RYAN W. BORING O CIVIL U NO.49506 0 �FG / ST eb 22, 2022 T CL u z0 z In � Q J ' � z Q J z o ° o r� t) ED a z W U U `D CC) \ CLJ r� e LL I 0 U � �o O L� ¢ CID PEI -4 a OV CD 2 � H z Q } Ca Z I— J Z Q Z Q u LLLJ w w v Q Q XM CD LLJ O ~ (U Z J (U Oof U U o M ALL RAFTERS AT 0,131"x3" NAILS TEED TTACH RAFTERS TO WALL w/(2) #8x3" TUE SCREWS OR (1) SIMPSON H2,54 NOTES- -CONTINUOUS BRACING TO BE 2x3 (MINIMUM) OF ANY SPECIES/GRADE -FASTEN BRACING TO EACH INTERSECTING FRAMING MEMBER w/ (2) 0.131"x3" NAILS -BRACING MAY BE SUBSTITUTED WITH FULL -HEIGHT BLOCKING BETWEEN FRAMING MEMBERS OR CONTINUOUS SHEATHING -UPLIFT CALCULATIONS ARE BASED ON ALLOWABLE WIND SPEEDS. EQUIVALENT ULTIMATE WIND SPEEDS ARE 129 MPH AND 154 MPH FOR 100 MPH AND 120 MPH ALLOWABLE WIND SPEEDS, RESPECTIVELY QN-17595/JN-72304/MP 8'-9" 1 4'-11 5/16" IV PFS Corporation Northeast Region APPROVED Michelle Baker 02/22/2022 Approval limited to Factory Built Portion ATTACH RAFTER TO RAIL w/(3) 0.131"x3" NAILS TOED, INTERCONNECT RAILS w/(3) 0.131"x3" NAILS PER BAY, AND USE (1) SIMPSON CS20 STRAP w/(4) 0131"x2.5" NAILS EACH END ACROSS RIDGE RYAN W. BORING '-1 3 CIVIL m NO.49506 2 O.C. O,o FGIST ATTACH RAFTERS TO WeL. 22' 2022 w/(2) #8x3" TOE SCRE UU OR (1) SIMPSHN H2.5A OF ILIA LL U Z cr� z Ln z z z � z a� z (--) J � U M co CU V m Ld z LL �W C r�V o Q ? z Q r J Q Q z ��0 V Q U _ LLJ w w p W Q O X Q r Z LJ H a z 3 pa N w 3 o m m a N �l \ a Cu 1. P[PMG SUPPDRT DWV 4'-D' O.C. VER. / 3'-D" G.C. HER, rA_1- DWV S SUPPLY LIN:-S P TE��IPE�eeTURE LIMITING DEVICE TO BE INSTP-LEDON ALL LAVATORIES, BEI_DW THE FLOOR SHOWN ARE TUBS AND SI-'�OWERS, 3, EACH FIXTURE SUPPLY RISER FITTED WITH S'-UTOFF VALVE TO BE SIZED BY THE ON -SITE I 4. WATER LINE SIZED BASED ON 30 PSI AND B(- MAX DEVELOPED LENGTH CONTRACTOR @ APPROVED BY 5. USE REMOV43LE TRAPS INDER ALL SINKS TU SERVE AS CL EANOUTS THE LOCAL BUILDING I 5. ALL SUPPLY AND DRAIN LINES BELOW THE F'_GOR ARE SUPPLIED AND LINSPEc T ❑R.— — — — — — INSTALLED ON SITE 3Y BUILDER B. WATER H[ISPROVIDED AND INSTALLED Oi`i-SITE BY BUILDER, WATER HEATER Di SCHARGE SHALL BE IN A NON-HAZARDEJS LOCATION INDICATES DRAIN INDICATES VENT 3" VENT — - INDICATES DWV PLUMBING ON -SITE BY BUILDER 3" RADON THROUGH VENT ROOF THROUGH COLD WATER SUPPLY ROOF ------- HUT WATER SUPP!_Y Z ALL DWV & SUPPLY LINES BELOW THE FLOOR SHOWN ARE I ¢ \ \ TO BE SIZED BY THE ON -SITE Cc CONTRACTOR & APPROVE➢ BY ' THE LOCAL BUILDING INSPECTOR L--------� XX we SHOWER LAV WASHER LAV NI / UTILITY SINK < \ \ \ LAV \- SN-11.884/ON-17596/JN 72304/M4, SHOWER v2 we 1/2 1/2' 3/4' LAV \ / WASHER �Y7 3/4' \ 1/2' 1/2 3/4' 3/4• LAV \ / KITCHEN C 1/2" 3/4' `3/4• vl UTILITY SINK \J i TUB/ J F SHOWER w w = LAV 3 / WC w ¢ 3/4' 3 3/4' 1/2 I � 1/2•� �3/a ` J I ate— z 1� `3/4• TUB/SHOWER 1/2 Boca / BOW VENT NAIL FOR MASS < /2 �I 1/2' WER PFS Corporation Northeast Region APPROVED Michelle Baker 02/22/2022 Approval limited to Factory Built Portion RYAN W. BORING '-A CIVIL NO. 49506 �O.o'PFGlSTER eb 22, 2022 0 U Z � Z_ In Q Z 0 J ' n 'Wn MU F-� 00mW l V _ � W \ CD o IQ -B CT_ CD QCo co Z > J Q�z � > o=ED Y O U y L W o Wz J o v� z _J X <L LHI ti z �3� SZCL CO O � A13 GENERAL NOTES 1. N/A 2. ALL PLUMBING NOT PROVIDED BY APEX HOMES TO BE SUPPLIED AND FIELD INSTALLED BY BUILDER. 3. N/A 4. BATH TUBS AND SHOWERS ARE LISTED BY AN APPROVED AGENCY. 5. HEIGHT OF WATERPROOFING IN TUB AND SHOWER SPACE IS 6'-0' A.F.F. MINIMUM. 6. INTERCONNECTION OF VENTS TO BE COMPLETED IN FACTORY WHERE PRACTICAL. 7. PLASTIC PIPE TO BE SUPPORTED EVERY 48'HOR[ZONTALLY AND VERTICALLY, 8. OPEN VENT PIPES EXTEND THROUGH THE ROOF 6' MINIMUM, OR 6' ABOVE ANTICIPATED SNGW ACCUMULATION, WHICHEVER IS GREATER. 9. HORIZONTAL VENT PIPES FORMING BRANCH VENTS SHALL. BE AT LEAST 6' ABOVE THE FLOOD LEVEL RIM OF THE HIGHEST FIXTURE SERVED. L0. DWV MATERIAL TO BE PVC Li. JOINTS AND CONNECTIONS IN THE DWV SYSTEM MUST BE GAS AND WATER TIGHT FOR THE INTENDED USE AND SHALL COMPLY WITH THE STATE / LOCAL BUILDING CODE. I2ALL DRAIN LINES TO BE SLOPED 1/4' PER FOOT TO MAIN. JOINTS BETWEEN DIFFERENT MATERIALS SHALL BE MADE WITH A MECHANICAL JOINT APPROVED FOR THE APPLICATION. " HORIZONTAL TO VERTICAL CONNECTIONS TO BE MADE WITH A LONG TURN TEE, 15. HORIZONTAL TO HORIZONTAL AND VERTICAL TO .HORIZONTAL DRAIN CHANGES IN DIRECTION SHALL BE MADE BY THE APPROPRIATE USE OF SANITARY TEES, WYES, SWEEPS, BENDS OR A COMBINATION ALLOWED PER CODE. 16. THE MAXIMUM OR FROM THE FIXTURE OUTLET TO THE TRAP WEIR SHALL NOT EXCEED 24' VERTICALLY AND 30, HORIZONTALLY. 17, MAXIMUM DISTANCE OF A FIXTURE TRAP TO VENT : 11/2' 6'1, 2' 68 0', 3-10'-0' 18. HOSE BI B BS WITH A HOSE CONNECTION SHALL BE PROTECTED BY A VACUUM BREAKER. I') MAXIMUM FLOW RATES TO BE'! SINKS AND LAYS.=2.2 GPM AT 60 PSI, SHOWERS=2.5 GPM AT 80 PSI, WATER CLOSET=1.6 GALLONS PER FLUSHING CYCLE 20, SUPPLY LINES ARE TYPE 'L' COPPER OR CROSS -LINKED POLYETHYLENE (PEX). 21, COPPER PIPE SHALL BE SUPPORTED EVERY G'-0' HORIZONTALLY, 10-0' VERTICALLY AND AT EACH STORY HEIGHT. 22, ALL JOINTS IN COPPER PIPE TO BE SOLDERED WITH AN APPROVED FLUX, SOLDERED OR MECHANICALLY JOINED PER CODE REQUIREMENTS. 23. PLASTIC PIPE SHALL NOT PENETRATE FIRE RATED ASSEMBLIES, METAL PIPE IS TO BE USED. 24. JOINTS AROUND PLUMBING FIXTURES SHALL BE MADE WATERPROOF AT FLOORS, WALLS AND COUNTERTOPS. 25, ONE FROST -FREE HOSE BIBB/SILL COCK TO BE SUPPLIED AND INSTALLED BY BUILDER IN FIELD. SEE NOTE 18 ABOVE 26. VACUUM BREAKERS TO BE LOCATED A MINIMUM OF 4' ABOVE FINISHED FLOOR WHEN FACTORY INSTALLED FIXTURES (I.E. CLOTHES WASHER). 27. N/A 28, WALL CONSTRUCTION FOR SHOWER RECEPTORS SHALL BE IN COMPLIANCE WITH ALL STATE AND LOCAL APPLICABLE CODES. 29. ANY STRUCTURAL MEMBERS SUBJECT TO DRILLING, CUTTING OR NOTCHING SHALL BE IN ACCORDANCE WITH ALL STATE AND LOCAL APPLICABLE CODES. 30. PIPING SHALL BE FIRE STOPPED AS REQUIRED BY ALL STATE AND LOCAL APPLICABLE CODES WITN MATERIAL EQUIVALENT TO CONSTRUCTION IN WHICH IT PENETRATES AND BE SUTABLE TO THE PIPE MATERIAL (SEE PG. A42 DETAILS). 31, FIRE STOPPING SHALL BE PROVIDED BEFORE IT IS COVERED OR CONCEALED. 32. WATER HEATERS SHALL BE INSTALLED ON -SITE PER ALL STATE AND LOCAL CODES. 33, ALL PLUMBING SHALL BE TESTED IN THE FACTORY AS DESCRIBED IN THE APEX HOMES QUALITY ASSURANCE MANUAL NO PLUMBING SHALL BE COVERED BEFORE TESTED. 34. FIELD INSTALLED PIPING BETWEEN IST AND 2ND FLDORS, AND ALL WORK DONE ON SITE SHALL BE APPROVED BY THE LOCAL BUILDING OFFICIAL AND FIELD TESTED PER ALL STATE AND LOCAL APPLICABLE BUILDING CODES. 35. FACTORY INSTALLED FIXTURE DRAINS AND ALL OPEN PIPE SHALL BE PROTECTED OR CAPPED AND LABELED FOR TRANSPORT. 36. INACCESSIBLE TRAPS SHALL NOT HAVE UNIONS, CLEAN -OUTS OR SLIP JOINTS. ACCESSIBLE TRAPS ONLY SHALL BE REMOVABLE WITH UNION IN TRAP SEAL OR HAVE CLEAN-OUTOPENING THE SAME SIZE AS THE TRAP. 37. WATER CLOSETS SHALL HAVE FLUSHING DEVICES AND FIXTURES AS REQUIRED PER ALL STATE AND LOCAL APPLICABLE BUILDING CODES. 38, THE POTABLE WATER SYSTEM SHALL BE FIELD DISINFECTED AS PER ALL STATE AND LOCAL APPLICABLE BUILDING CODES. 39. CONCEALED PIPING IN UNHEATED AREAS, INCLUDING OUTSIDE WALLS, SHALL BE PROTECTED AGAINST FREEZING. PIPING SHALL BE KEPT OUT OF UNHEATED AREAS WHENEVER POSSIBLE. 40. HOSE SPRAYER (IF SUPPLIED) FOR TUB/SHOWER SHALL HAVE A DIVERTER THAT PROVIDES A VACUUM BREAKER CI,E. BATH SPOUT DIVERTER) OR SHALL BE PROVIDED WITH A VACUUM BREAKER. 41. 1ST FLOOR FIXTURES SHALL CONNECT INTO HORIZONTAL BUILDING DRAIN MORE THAN 10 PIPE DIAMETERS DOWNSTREAM OF A STACK BASE AND WILL NOT CONNECT INTO A 2ND FLOOR DRAIN STACK. 42. ONE PIECE FIBERGLASS TUB/SHOWER UNITS OR ONSITE TILED WALLS TO BE FACTORY INSTALLED OVER A MOISTURE RESISTANT GVPSUM 6'-0' MINIMUM HIGH. 43. BASEMENT HOME MODELS SHALL 6E PROVIDED WITH A 2' VENT STUBBED BELOW THE 1ST FLOOR, CAPPED AND LABELED BY APEX HOMES. 44. BATHTUBS INCLUDING GARDEN OR HOT TUBS OR WHIRLPOOLS SHALL HAVE A L 1/2' MINIMUM OVERFLOW PROVI➢ED. 45. HEAT TRAPS SHALL BE INCLUDED FOR DOMESTIC WATER HEATING SYSTEMS, 46. EACH LENGTH OF PIPE AND FITTING, TRAP, FIXTURE. MATERIAL AND DEVICE IN A PLUMBING SYSTEM TO BEAR THE IDENTIFICATION OF THE MANUFACTURER. FOR ADDITIONAL INF❑RMATION PLEASE REFER TO THE MASSACHUSETTS 248 CMR 10.00 UNIFORM STATE PLUMBING CODE PLUMBING MATERIAL SPECIFICATI❑NS 1, PVC PLASTIC PIPE - SCHEDULE 40 OR BD, ASTM D 1795 2. PVC PLASTIC PIPE FITTINGS - SCHEDULE 40, ASTM ➢ 2466 3. PVC SOLVENT CEMENT -ASTM D 2564 4. ABS PIPE - SCHEDULE 40 OR 80, ASTM D 1527 5. ABS SOLVENT CEMENT - ASTM ➢ 2235 6. SOLDER - ASTM B 828 7. RELIEF VALVE - ANSI Z 21.22 8. CROSS -LINKED POLYETHYLENE CPEX) PLASTIC TUBING - ASTM f B77 9. COPPER DRAINAGE TUBING - ASTM B 306 10. GEL COATED GLASS - FIBER REINFORCED POLYESTER RE ISN SHOWER, SHOWER RECEPTOR AND SHOWER STALL - ANSI Z24.2 11. PLASTIC TUBS - ANSI Z124.1 12. STAINLESS STEEL FIXTURES - ASME A112.19.3M 13. VITREOUS CHINA FIXTURES - ASME A112.19.2M 14. FCRMED METAL PORCELAIN FIXTURES - ASME A112.19.4M 15. ENAMELE➢ CAST IRON FIXTURES - ASME A112.19.IM 16, MATERIALS, FIXTURES AND EQUIPMENT SHALL BE IN COMPLAINCE WITH ALL STATE AND LOCAL APPLICABLE BUILDING CODES. PPS Corporation Northeast Region APPROVED Michelle Baker 02/22/2022 Approval limited to Factory Built Portion SN-11884/QN-1754/JN-72304/MA 0 z � �ON /<-�1�: � W z o Q [] H- LD 3'0 12' ABOVE H~ Q 8 BELOW W Pq �' 2 � 2'0- TO DI -1 1/2'x3' INCREASE -3/4'0 FLEXIBLE �� � -.D1/2' TEE GARBAGE DWV PIPE 11 nn 1 I/2' SAN TEE DISPOSAL 45' EL u W --_) -1 1/2'0 ➢WV (CPT) DWV COUPLING _ �CONT. 0 DWV PIPE M 2 0 WASTE 1 1/2' SAN TEE 2' P TRAP CUNT. -WASP TRAP O j 11/-' FLR 2' INSTALL CLEAN OUT 1/210 ' AS SHOWN 1 m INSTALL CLEAN OUT FIR SOLVENT CEMENT 1111MTV I i FLR AS SHOWN APPROVED LLJ DO KIT. SINK DRAIN 8 VENT FI LDONN CONNECTION B TWFN W/ CRT DW 8 GAR DISP. KIT S:NK SUPPLY MO�ULESOR. BSMT FIXTURES FIXTURES a KIT. SINK DRAIN 8 VENT EACH FIXTURE SHALL BE EACH FIXTURE SHALL BE W/ OPT ➢ WpPT ➢ SUPPIY V �' Q L� INDIVIDUALLY VENTED INDIVIDUALLY VENTED F4 �1 L 3' VENT MIN. 6' ABOVE ROOF Q Vj Q V Z M 6' MIN. 3' IN. VENT PENETRATION THROUGH ROOF 3' COUPLING MADE WATERTIGHT, SITE INSTALLED IF N PRACTICAL IN FACTORY 12' MIN TO BRANCH PIPE AND BEGINNING 3'm P OF REDUCTION AT REDUCER ~ ALT I/2' VENT TO VENT z } J TERMINAL FOR SINK a WASHER 1 1/2' BRANCH VENT 3'x3'xl t/2' TEE Q ~ 2' VENT RE SINT Q Z > FOR FUTURE BSMT WATER CIO. FLANGE O LAUNDRY, STUBBED O THRU FLR, TAGGED 4'x3' 8 CAPPED kF FLR � O a- OpT. BALK 4MA BACK TO BACK 3' COMBO WYE 8 I/8' BEND LJ J N 3'-6' MAX. FIXTURE USINGER CLO USING (BY BUILDER) J H- 3'-6' MAX, COMMON VEMMON VENT X Q Q q O 5-0-MAX " LEI 3'-6MAIN VENT W C DRAM AND VENT KIT. SINK ONE 3'0 STACK PER LIVING UNIT MIN. o (U Z LAV. TUB/SHOWER CIO. J (UFLRW QFLR 1 1/2' VENT PEI SEE NOTE 7N �- COt 1/2' SANTEE2'DRAIN SLOPE 'J OLOSIZE ACCORDING t/2'0 TO FIXTURE LOAD �G TYPIrAl DWV SCHEMATIC L I/2' P TRAP INSTALL CLEAN OUT �•' VACUUM RELIEF NEEDED WHEN TANK FLR AS SHOWN m IS ON FIRST 6 SECOND FLUOR PER ISOLATION VALVES DWELLING ISOLATION Q VALVE SHALL BE ACCESSIBLE TO EAC Z Q I LIVING UNIT TEMPERATURE a PRESSURE LAV SUPPLY Y RELIEF VALVE LAV. DRAIN 6 VENT WATER GLOW- -- WATER FLOW EACH FIXTURE SHALL BE Q INDIVIDUALLY VENTED MAIN SHUTOFF. VALVE HOT WATER OUTLET FIXTURE SHUTOFF VALVE U COLD WATER SUPPLY TO FIXTURE w N 01 N COLD WATER INLET ALTERNATE TEMPERATURE 8 C PRESSURE RELIEF VALVE LOCATIO Q (U DISCHARGE LINE ( TO BE WASHER BOX N EXTENDED TO AN OPEN DRAIN PRESSURE TEMPERATURE RELIEF 1 1/2' VENT VALVE SHALL PIPE TO AN AIR GAP NEAR FLR IN THE SAME WASHER BOX HOSE B H LD SPACE AS WTR HTR THEN WHEN W/ A Z J WTR HTR IS ON FIRST OR SECOND2' SAJdDMRIRESTACK VENT - Cl� ; FLR DRAIN SHALL PIPE BELOW �lH' MIN. 30' MAX. OF StS Ci li Q p FIRST FLR PROVIDED IN PLANT I I I I I DRAIN SHALL PIPE 8 DISCHARGE 2' P TRAP INDIRECTLY TO A HAZARD FREE POINT 6' MIN. AIR GAP 2'0 CyGN � Q- Q HOT WATER HEATER P N FLR O RYAN W. BORING i ( METAL FOR FUEL BURNING EATER ) U CIVIL (q I "" DRAIN FROM DRAIN PAN NO. 49506 � TO BELOW FIRST FLOOR C PROVIDED IN FACTORY ) WHEN TANK IS ON FIRST OR SECOND FLOOR WASHER DRAIN e VENT WATER HEATER DETAIL EACH FIXTURE SHALL BE ,n n rf`•Q N (u C y SEE NOTE 32 INDIVIDUALLY VENTED WASH R SUPPLY rO� �`01 S.T& WATER HEATER NOTES , NO FUEL HORNING WATER HEATERS IN OR OFF SLEEPING, BATH TOILET ROOMS �S,+L�_ L PRUVIOE DOOR OR PANEL LARGE ENOUGH TO REPLACE WATER HEATER. ➢O NOT PLACE ACCESS THRU BEDROOM CLOSET SPACE FOR WATER HEATER SHALL BE PROVIDED W FACTORY. INSTALLATION SHALL BE PROTECTED FROM FREEZING. I eb 22, 2022 o q Q" 414 TOP LOADED BEAMS 2-PLv BEAM 1-PLv BEAN 4-PLY BEAN ARP I I.: 0.131'e3' NAILS 0.131 x3 NARS SC2EVSE➢ FASTENING REQUIREMENTS FOR MULTIPLE PLY LVL MEMBERS 2- AND 3-PLY MEMBERS 12' OR LESS x 15' MEMBER BEAMS: USE (2) ROWS OF 0.131'x3' NAILS @ 8" ❑.C, 14", 16" OR 18' x 1.5" MEMBER BEAMS USE (3) ROWS OF 0.131"x3" NAILS @ 8' ❑.0 20",22" OR 24' x 1.5" MEMBER BEAMS: USE (4) ROWS OF 0.131'x3' NAILS @ 8" O.C. 4-PLY MEMBERS 16' OR LESS x 1.5" MEMBER BEAMS USE (2) ROWS OF APPROVED SCREWS @ 24' O.C. 16' TO 24' x 1.5" MEMBER BEAMS: USE (3) ROWS OF APPROVED SCREWS @ 24' D.C. 1' 0.111'x3' NAILS (IS' MENBER 0.111'x3.5' wA1LS (1.75' MENBERS) 6' BUILT UP COLUMN FASTENING NOTES: -FOR 1.75' THICK MEMBERS, USE 0.131'x3.5" NAILS IN PLACE OF 0.131"x3" NAILS. -THE FOLLOWING SCREWS ARE APPROVED FOR USE IN CONNECTING MULTIPLE PLIES OF LVL: -SIMPSON SDW WOOD SCREWS -SIMPSON SDS WOOD SCREWS -USP WS WOOD SCREWS FASTENMASTER TRUSSLOK WOOD SCREWS -IF THE FASTENER POINT PENETRATES A MINIMUM OF 75% OF THE 4TH PLY OF THE BEAM, THEY MAY BE APPLIED FROM ONE SIDE OF THE BEAM; OTHERWISE, THE FASTENERS MUST BE APPLIED FROM BOTH SIDES AND STAGGERED. -LOAD MUST BE APPLIED EVENLY TO ALL 4 PLIES; OTHERWISE, USE CONNECTIONS FOR SIDE LOADED MEMBERS. -FASTENING SPACING IS FOR EACH ROW. STAGGER SPACING BETWEEN ROWS OF FASTENERS. SN11o34/QN-1759o/JN-72304/MA H �D ,,—1 V Q z D � � w LD z z a H LIJ u Q U 0 CU J L� m SIDE LEADED BEAMS LL-1 Lv PFax 3-^LY BGx -XLY AEAX O V O q LL CL • • • • • `-O.t3t OR Lot 3' OR 12' BBLtS Bt62'xS.3.5' NAILS NA S NAIL FASTENING REQUIREMENTS FOR MULTIPLE PLY LVL MEMBERS (2) 1.5' MEMBER BEAMS; -USE (3) ROWS OF 0.131"x3" NAILS @ 12' D.C. (575 PLF MAX. UNIFORM LOAD) -USE (3) ROWS OF 0.131"z3" NAILS @ 6" O.C. (1,150 PLF MAX. UNIFORM LOAD) (2) 175' MEMBER BEAMS -USE (3) ROWS OF 0.162'x3.5" NAILS @ 12" ❑.C. (845 PLF MAX. UNIFORM LOAD) -USE (3) ROWS OF 0,162'x3.5" NAILS @ 6' O.C. (1,690 PLF MAX. UNIFORM LOAD) (3) 1,5' MEMBER BEAMS -USE (3) ROWS OF 0.131'x3' NAILS @ 12" O.C. (431 PLF MAX. UNIFORM LOAD) -USE (3) ROWS OF 0.131"x3" NAILS @ 6" O.C. (863 PLF MAX. UNIFORM LOAD) (3) 1.75' MEMBER BEAMS -USE (3) ROWS OF 0.162'x3.5' NAILS @ 12' ❑.C. (635 PLF MAX. UNIFORM LOAD) -USE (3) ROWS OF 0.162'x3.5" NAILS @ 6" D.C. (1,270 PLF MAX. UNIFORM LOAD) (4) 1.5" OR 1.75' MEMBER BEAMS: -USE (2) ROWS OF 1/2' BOLTS @ 12' O.C. (580 PLF MAX. UNIFORM LOAD) -USE (3) ROWS OF 1/2' BOLTS @ 12' ❑.C.(870 PLF MAX. UNIFORM LOAD) NOTES -VALUES APPLY TO COMMON A307 BOLTS. BOLT HOLES MUST BE THE SAME DIAMETER AS THE THE BOLTS. WASHERS MUST BE USED UNDER THE BOLT HEADS AND NUTS. -THE SPECIFIED NAILING APPLIES TO BOTH SIDES OF A 3-PLY BEAM. -7' WIDE BEAMS MAY NOT BE LOADED FROM ONE SIDE ONLY, THEY MUST BE LOADED FROM BOTH SIDES AND/OR TOP LOADED. LOAD DURATION FACTORS MAY BE APPLIED TO THE LOADS LISTED ABOVE. -LVL DESIGN IS SUFFICIENT FOR LVL GRADES WITH A SPECIFIC GRAVITY OF 0.5 OR BETTER PFS Corporation Northeast Region Michelle Baker 02/22/2022 Approval limited to Factory Built Portion w RYAN W. BORING � CIVIL U NO.49506 4 �Oc eb 22, 2022 � z ¢ ' H- -j Q ¢ Z > �o o� W W g W N Z o LiCQ q o X ¢ Z Wryer o V) (U Z �3 Z as N CL q oM Yz Q I I I I I O U (U tt N M I OJ N a J U > H = F n u Q a-- d SN-11884/QN-17596/JN-72304/MA A � ;� • .gin -� N '4 15 ------------------------------------------------------ / * 1' Orb Telf #e7 d / - , 979 T,L. (PLF) ( �h 1 1 I I I i i 1 I I I I i I i I I I `BUILDER'S RAPE TO DESIGN FOUNDATION TO THE LOADS LISTED. APPROVED AND INSPECTED BY THE LOCAL AHJ* i *REQUIRED FLOOD VENTS BY FOUNDATION DESIGNER* I I I j I 13'-3' 768 T.L. (PLF) 32'-6' 766 T.L. (PLF) 12'-4' .768 T.L. (PLF) 7'-11' 1044 T.L. (PL1J) I I I I 6'-7 1/2' 6'-7 112' BLOCK PIER FOR CRHVL SGRCE 8'-3' 8'-3' 8'-3' 7'-9' 6'-2' 6'-2' 3'-11 1/2' 3'-I1 1% I �p I I I I I N I N I ;POINT ,LOAD I I I I I�I IZI IL I I 12644q I L_J L—J L._..J bq., L_J L._J l,-.TJ L—J L_J i I PENT !Ji POINT Pp1NT I I 1 I LOAD 16• LOAD LOAD I I I i 9460R COK. FOOTER 9393# 2574# I I 1 , I o — — — m i _ i 1—*NOTE: GIRDER SPLICES FOUNDATION ACCESS PROVIDED ANDI MUST FALL OVER PIERS, m �qh• L—'------- INSTALLED ON -SITE BY BUILDER AND IS 849 T.L. (PLF) 849 T.L. (PLF) I >. y a L_____-__ ___� TO BE APPROVED BY LOCAL AHJ r-------- ---J T------------� I '... H= ----------- I I —__— 7 r- ----- I I I I I � J v' I 1 I I I 1 I I I 979 T.L. (PLF) 9' MINIMUM GDNCR£TE WALLS I I L---------------------------------------- --- ------------------------------------J N ,177::Z— ___________________________—_------ StXIT19RJ___.—_____.— —._—____--..— — —.__..— ___ _ ,SiHD14RJ 1 1/2' te29a I 1929a i 1 I i I I I I I I L--------------------------------------------------------------------- NwT'ag CUM vim LZW 4 c'. A0 i CZt9✓-� T5 ,.- w #A"`t 4 LlawCltNl F❑UNDATION DRAWINGS ARE TO BE USED AS A GUIDE ONLY, APEX HOMES WILL NOT ACCEPT ANY LIABILITY OR RESPONSIBILITY FOR INCORRECT F❑UNDATIONS, MOTES; 6, MAX ANCHOR BOLT SPACING; 6'-0' O.C. (4'-0' O,C, MAX IN AREAS WHERE WIND VELOCITY I. FOR ADDITIONAL INFORMATION SEE TYPICAL F❑UNDATION DRAWING A15,16 OF THIS SET IS LD OR EXCEEDS 100 MPH) ?, PERIMETER RAIL ATTACHED TO SILL WITH 16d NAILS AT 6' O.C. 7. WINDOWS OR VENTS (INSTALLED BY BUILDER) ARE REQUIRED TO PROVIDE 1/150 OF FLOOR 1 PIER FOOTINGS BASED UPON 2000 PSF ALLOWABLE SOIL BEARING PRESSURE AREA AS FREE VENTILATION AND SHALL BE LOCATED AS CLOSE TO CORNERS AS POSSIBLE 4, CONCRETE COMPRESSIVE STRENGTH; 2500 PSI 8, NOTES ON THIS PAGE TAKE PRECEDENCE OVER NOTES ON TYPICAL FOUNDATION DWG, 5. M OR S TYPE MORTAR TO BE USED A15/A16 �N O RYAN W. BORING � 'CIVIL No.49506 O A�QT L eb 22, 2022 v z z <E _I Q z z 0 0 u z LD p `D o Cu d Z LJ = cj o WaLJ I- Pa w x Q < W sn Cu ILi 3 Pq z Z q Y (U (LJ N cif RJ A Cu � J �z. Q N J �<� I I I I I CL A 6