Loading...
HomeMy WebLinkAbout21 Stiles Rd solar plans 8NEC 690.15 (B) & NEC 690.33(D)(2) A WARNING SINGLE 120-VOLT SUPPLY DO NOT CONNECT MULTIWIRE BRANCH CIRCUITS NEC 710.15(C) & 692.9 (C) AWARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM NEC 705.12(D) & NEC 690,59 A WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL NEC 110.27(C) & OSHA 1910.145(F)(7) A WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION 706.15(C)(4) & 690.13(B) A WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES: TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED AMPACITY OF BUSBAR NEC 705.12(B)(3)(3) A WARNING THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE •' • wI(9]l Q INVERTER SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO AkE«rR, SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY IFC 605.11.3.1 1 & 690.56(C - A CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED -- -- - -- -- - --- NEC 705.12(D) & NEC 690.59 AWARNING 'P6U" ""'''-""•" ARC FLASH AND SHOCK HAZARD POWER SOU I'll, UTAPPROPRIATE PPE REQUIRED CONNECTION. DO NOT 1< RELOCATE THIS OVERCURRENT DEVICE. NEC 705.12(C) & NEC 690.59 NEC 706 15(C) AND NEC 110.16 z NEC 690.13(B) AWARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM NEC 705.12(D) & NEC 690.59 EVERY 10' ON CONDUIT AND ENCLOSURES NEC 690.31(0)(2) EVERY 10' ON CONDUIT AND ENCLOSURES NEC 690.31(D)(2) NOTES: 1. NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON. 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C. ARIAL FONT. 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP -RIVETS OR SCREWS PHOTOVOLTAIC D ISCONNECT NEC 69, MM90 A WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT 706.15(C)(4) & 690.13(B) A WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION 706.15(C)(4) & 690.13(B) A WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL NEC 110.27(C) & OSHA 1910.145(F)(7) ARRAY CLIENT: BRIAN MORIN 21 STILES ROAD, YARMOUTH, MA 02664 AHJ: TOWN OF YARMOUTH (MA) UTILITY: EVERSOURCE ENERGY (EASTERN MA) PHONE: (508) 737-1049 EMAIL: BMORIN21@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 19 X 370 = 7.030 kW SYSTEM SIZE (NEC): 5.000 kW @ 240V MODULES: 19 X FREEDOM FOREVER: FF-MP-BBB-370 OPTIMIZERS: 19 X SOLAREDGE S440 INVERTER: SOLAREDGE SE5000H-US ISHI I REVISIONS NO. REVISED BY DATE FREEDOM FOREVER LLC 135 ROBERT TREAT PAINE DR., TAUTON, MA 02780 Tel: (800) 385-1075 GREG ALBRIGHT CONTRACTOR LICENSE: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-Al; CONSTRUCTION SUPERVISOR LICENSE CS-111662; MASTER ELECTRICIAN 1136 MR NEC 690.31(13)(3) & (4) LABELS JOB NO: I DATE I DESIGNED BY: SHEET: 262874 917/2022 Z.V. PV-7