HomeMy WebLinkAbout9 Victory Ln plan 2GENERAL NAILING SCHEDULE JOINT DESCRIPTION IVUMBE.R OF;; NUMBER .OF C04MON NAIL, BOX 1iLS ..' NAIL S'ACI ROOF FRAMING BLOCKING TO RAFTER (TOE -NAILED 2-8D 2-1 OD EACH END - AIL D I BOARD TO RAFTER (END -NAILED) RIM - 6D 2 1 - 6D 3 1 EACH END WALL FRAMING TOP PLATES AT INTERSECTIONS (FACE -NAILED) 4-16D 5-16D AT JOINTS STUD TO STUD (FACE NAILED) 2-16D 2-16D 24" O.C. HEADER TO HEADER (FACE -NAILED) 16D 16D 16" O.C. ALONG EDGES FLOOR FRAMING JOIST TO SILL, TOP PLATE OR GIRDER (TOE -NAILED) 4-8D 4-10D PER JOIST BLOCKING TO JOIST (TOE -NAILED) 2-8D 2-10D EACH END BLOCKING TO SILL OR TOP PLATE (TOE -NAILED) 3-16D 4-16D EACH BLOCK LEDGER STRIP TO BEAM OR GIRDER (FACE -NAILED) 3-16D 4-16D EACH JOIST JOIST ON LEDGER TO BEAM (TOE -NAILED) 3-8D 3-10D PER JOIST BAND JOIST TO JOIST (END -NAILED) 3-16D 4-16D PER JOIST BAND JOIST TO SILL OR TOP PLATE (TOE -NAILED) 2-16D 3-16D PER FOOT ROOF SHEATHING WOOD STRUCTURAL PANELS RAFTERS OR TRUSSES SPACED UP TO 16" O.C. 8D 10D 6" EDGE / 6" FIELD RAFTERS OR TRUSSES SPACED OVER 16" O.C. 8D 10D 4" EDGE / 4" FIELD GABLE ENDWALL RAKE OR RAKE TRUSS W/O GABLE OVERHANG 8D 10D 6" EDGE / 6" FIELD GABLE ENDWALL RAKE OR RAKE TRUSS W/ STRUCTURAL OUTLOOKERS 8D 10D 6 EDGE / 6 FIELD GABLE ENDWALL RAKE OR RAKE TRUSS W/ LOOKOUT BLOCKS 8D 10D 4" EDGE / 4" FIELD CEILING SHEATHING GYPSUM WALLBOARD 5D COOLERS - 7" EDGE / 10" FIELD WALL SHEATHING WOOD STRUCTURAL PANELS STUDS SPACED UP TO 24" O.C. 8D 10D 6" EDGE / 12" FIELD 1/2" AND 25/32" FIBERBOARD PANELS 8D1 - 3" EDGE / 6" FIELD 1/2" GYPSUM WALLBOARD 5D COOLERS - 7" EDGE / 10" FIELD FLOUR SHEATHING WOOD STRUCTURAL PANELS 1" OR LESS 8D 10D 6" EDGE / 12" FIELD GREATER THAN 1" 10D 16D 6" EDGE / 6" FIELD 1 CORROSION RESISTANT 11 GAGE ROOFING NAILS AND 16 GAGE STAPLES ARE PERMITTED, CHECK IBC FOR ADDITIONAL REQUIREMENTS. NAILS- UNLESS OTHERWISE STATED, SIZES GIVEN FOR NAILS ARE COMMON WIRE SIZES. BOX AND PNEUMATIC NAILS OF EQUIVALENT DIAMETER AND EQUAL OR GREATER LENGTH TO THE SPECIFIED COMMON NAILS MAY BE SUBSTITUTED UNLESS OTHERWISE PROHIBITED. WALL OPENINGS - HEADERS IN LOADBEARING WALLS & NON-LOADBEARING WALLS HEADER SPAN (FT.) MINIMUM HEADER SIZE REQUIREMENTS AT EACH END OF HEADER NUMBER OF FULL -HEIGHT STUDS UPLIFT (LB.) LATERAL (LB.) HEADERS IN LOADBEARING WALLS 2 2-2X4 1 277 132 3 2-2X4 2 416 198 4 2-2X4 2 554 264 5 2-2X4 3 693 330 6 2-2X6 3 831 396 7 2-2X8 3 970 462 8 2-2X12 3 1,108 528 9 3-2X10 3 1,247 594 10 3-2X12 4 1,385 660 11 4-2X10 4 1,524 726 HEADERS IN NON-LOADBEARING WALLS AND WINDOW SILL PLATES" 2 1-2X4 (FLAT) 1 60 132 3 1-2X4 (FLAT) 2 90 198 4 1-2X4 (FLAT) 2 120 264 5 1-2X4 (FLAT) 3 150 330 6 1-2X6(FLAT) 3 180 396 7 1-2X6 (FLAT) 3 210 462 8 1-2X6 (FLAT) 3 240 528 9 2-2X6 (FLAT) 3 270 594 10 2-2X6 (FLAT) 4 300 660 11 2-2X6 (FLAT) 4 330 726 12 2-2X6 (FLAT) 5 360 792 FOR NON -LOADING BEARING WALLS AND WINDOW SILL PLATES, 2-2X4 (FLAT) CAN BE SUBSTITUTED FOR 1-2X6 (FLAT) 161a[oy_l=Ito] Iad 1. THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR THE VERIFICATION OF THE CONDITION OF ANY EXISTING STRUCTURE, EQUIPMENT OR APPLIANCE AS PART OF BASIC SERVICES UNLESS IT IS PART OF ARCHITECT'S SCOPE STATED IN THE AGREEMENT AND VERIFICATION IS MADE ONLY BY VISUAL OBSERVATION. IF THE ARCHITECTS DOCUMENTS REQUIRE CHANGES DUE TO CONDITIONS NOT VISUALLY OBSERVABLE AT THE TIME OF PREPARATION OF THESE DOCUMENTS, THE SERVICES WILL BE ADDITIONAL SERVICES. 2. STRUCTURAL ENGINEER OR ARCHITECT SHALL PERFORM FRAMING INSPECTION WHEN FRAMING IS COMPLETE AND PRIOR TO ENCLOSURE BY INTERIOR WALL PLASTER BOARD/FINISH. 3. CONTRACTOR SHALL SCHEDULE AND PROTECT FROM WEATHER ALL EXISTING HOUSE COMPONENTS AND INTERIORS DURING CONSTRUCTION AND CONSTRUCT TEMPORARY STRUCTURES/ENCLOSURES AS MAY BE NECESSARY TO INSURE SUCH PROTECTION. 4. CONTRACTOR SHALL SITE INSPECT ALL EXISTING VS. PROPOSED CONDITIONS PRIOR TO AND DURING CONSTRUCTION AND NOTIFY ARCHITECT OF ANY DESCREPANCIES AND/OR CHANGES THAT MAY BE ENCOUNTERED. 5. CONTRACTOR SHALL CONSTRUCT AND MAINTAIN TEMPORARY WALLS/ SHORING ETC. TO MAINTAIN/PROTECT EXISTING HOUSE AND STRUCTURAL INTEGRITY OF EXISTING HOUSE. 6. CONTRACTOR SHALL SITE INSPECT/VERIFY ALL EXISTING VS. PROPOSED CONDITIONS PRIOR TO AND DURING CONSTRUCTION AND MAKE ADJUSTMENTS AS NECESSARY, W/ ARCHITECT'S APPROVAL, TO ENSURE COMPLIANCE WITH DESIGN INTENT. 7. DASHED LINES INDICATED EXISTING CONDITIONS TO BE REMOVED/ALTERED. 8. WHERE AN ITEM IS REFERRED TO IN SINGULAR NUMBER IN THE CONTRACT DOCUMENTS, PROVIDE AS MANY SUCH ITEMS AS ARE NECESSARY TO COMPLETE THE WORK. 9. ARCHITECT'S DRAWINGS DEMONSTRATE DESIGN INTENT. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COMPLETE THE WORK IN A MANNER THAT ACHIEVES DESIGN INTENT. 10. THE CONTRACTOR IS RESPONSIBLE FOR THE PERFORMANCE OF THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND SHALL BE EXCLUSIVELY RESPONSIBLE FOR ITS CONSTRUCTION MEANS, METHODS, SEQUENCES, WARRANTIES, AND PROCEDURES, AND FOR CONSTRUCTION SAFETY. SIDING (SEE ELV "TYVEK" HOUSEWI 1/2" CDX PLYW( 2X4 ® 16" O.C. R-19 FBGLS INS 2 MIL. POLY VAI 1/2" GYP. BOAR TYP. EXTERIOR SCALE 1-1/2" = 1'-0" WALL FRAMING NOTES: 1. ALL FRAMING LUMBER SHALL BE HEM -FIR GRADE NO. 2 OR S.P.F. (SPRUCE - PINE - FIR) GRADE NO. 1 AND 2 OR APPROVED EQUAL (UNLESS OTHERWISE SPECIFIED) AND SHALL MEET THE REQUIREMENTS OF THE AMERICAN FOREST AND PAPER ASSOCIATION, THE MINIMUM ALLOWABLE BENDING STRESS (Fb) SHALL BE 1050 P.S.I. THE MINIMUM ALLOWABLE COMPRESSION STRESS (Fc) SHALL BE 400 P.S.I. THE MINIMUM ALLOWABLE MODULUS OF ELASTICITY (E) SHA_L BE 1,400,000 P.S.I. 2. ALL LVL'S TO BE BOISE CASCADE OR I - LEVEL WEYERHAUSER VERSA -LAM 3100FB OR APPROVED EQUAL. THE MINIMUM ALLOWABLE BENDING STRESS (Fb) SHALL BE 3100 P.S.I. ALL LVL POSTS TO BE VERSALAM 1.7 2650 FB, 1.8E PARALLAM PSL OR APPROVED EQUAL.NISTALL LVL'S IN ACCORDANCE 'WITH THE MANUFACTURER'S INSTRUCTIONS. 3. USE 3/4" TONGUE AND GROOVE STRUCTURAL GRADE FIR PLYWOOD FLOOR SHEATHING, 5/8" EXTERIOR STRUCTURAL GRADE FIR (C.D.X.) PLYWOOD ROOF SHEATHING, AND 1/2" EXTERIOR STRUCTURAL GRADE FIR (C.D.X.) AT WALLS. ALL JOINTS SHALL BE BLOCKED WITH LUMBER OR OTHER APPROVED SUPPORTS. 4. PROVIDE SOLID BLOCKING BETWEEN FLOOR JOISTS AND/OR DOUBLE ALL JOISTS UNDER EACH PARTITION. 5. USE FULLY NAILED METAL CONNECTORS (TECO, SIMPSON, OR EQUAL), JOIST, OR BEAM HANGERS WHEN JOISTS OR BEAMS FRAME INTO OTHER JOISTS OR BEAMS. PROVIDE METAL POST CAPS AND BASES FOR ALL POSTS. 6. FOR LVL BEAMS OR HEADERS PROVIDE SOLID 4X4 LVL MINIMUM POST SUPPORTS FOR DOUBLES AND SOLID 4X6 OR 6X6 LVL MINIMUM POSTS FOR TRIPLE BEAMS OR HEADERS, OR AS OTHERWISE SPECIFIED ON THE PLAN. 7. ALL PLYWOOD FLOOR SHEATHING SHALL BE GLUED TO SUPPORTING WOOD FRAMING MEMBERS USING AMERICAN PLYWOOD ASSOCIATION (A.P.A.) GLUED FLOOR SYSTEM. WOOD GLUE TO BE CONTECH, INC. PL400 SUBFLOOR CONSTRUCTION ADHESIVE, OR APPROVED EQUAL. 8. BUILT-UP BEAMS (3 PLY MAXIMUM) USING CONVENTIONAL FRAMING LUMBER SHALL BE FULLY SPIKED TOGETHER WITH 2-10D NAILS AT 12" O.C. LVL BEAMS (4 PLY MAXIMUM) TO BE THRU-BOLTED WITH 1/2 INCH DIAMETER THRU-BOLTS OR EQUIVALENT POWER SCREWS STAGGERED TOP AND BOTTOM AT 16 " O.C. OR AS OTHERWISE REQUIRED BY THE MANUFACTURER. 9. ALL MANUFACTURERED FLOOR I -JOISTS TO BE DESIGNED BY THE SUPPLIER/MANUFACTURER. SUBMIT SHOP DRAWINGS AND CALCULATIONS TO THE ENGINEER PRIOR TO FABRICATION. OVER CONCRETE OR MASONRY BLOCK FOUNDATION Outside Elevation Extent of header (two braced wall segments) Extent of header (one braced wall segment) 9 ) Pony wall height, ° ° ° 0 ° ° ° ° ° ° ° ° ° ° Min. 3" x 11-1/4" net header ° ° ° ° Header shall be Top plate 12' Max. oo 10 fastened to the continuity is total ° ° CAI .X king stud with required per wall 0O CU 0° 6-16D sinker nails R602.3.2 height ° ° 00 ° a) 00 ° Minimum 1000 lb header -to- ° ° U) ° ° jack -stud strap shall be centered 10' 00 00 at bottom of header and installed Max. ° on backside as shown on ° ° 0 height 0 0 0 4) side elevation °° ° 0/ 2' to 18' (finished width) °° ° Braced wall line with °° °° Min. number of continuous sheathing ° ° ° ° studs shown °° No. of jack studs Full-length per table R502.5(1&2) kinq stud 2 Anchor bolts per R403.1.6 required Foundation per code Side Elevation Min. 1000 Ilk tension strap,. Strap shall be centered at bottom of header. Sheathing filler if needed 16d sinker nails in 2 rows @3"0.C. Wood Structural panel must be continuous from top of wall to bottom of wall, or from top of wall to permitted splice area Full-length king studs 3/8" min. thickness wood structural panel sheathing Not to scale Fasten sheathing to header with 8d common nails in 3-in. grid pattern as shown and 3 in. o.c. in all framing (studs and sills) typ. 20 For a panel splice (if needed), panel edges shall occur over and be nailed to common blocking and occur within the middle 24 in. of wall height. One row of 3 in. o.c. nailing is required at each panel edge. O Min. length based on 6:1 height -to -width ratio. For example: 16 in. min. for 8 ft. height. TOP PLATE SPLICE BUILDING DIMENSION OF WALL CONTAINING TOP PLATE SPLICE :(FT.) SPLICE LENGTH (FT.) 12 16 20 24 28 32 36 40 50 60 70 80 NUM B.E.R OF 16D COMMON NAILS PER EACH SIDE OF SPLICE 2 4 6 8 8 NP NP NP NP NP NP I NP NP 4 4 6 7 8 10 12 14 16 NP NP NP NP 6 4 6 7 8 10 12 14 16 20 24 NP NP 8 4 6 7 8 10 12 14 16 20 24 28 32 NP= NOT PERMITTED WALL CONNECTIONS FOR UPLIFT UD PACING STS(LB.j 12" O.0 127 16" O.0 169 24" O.0 253 * TABLE TAKEN FROM- ENDWALL ASSEMBLIES WALL HEIGHT (FT.) 8 10 12 14 16 18 20 PLATE -TO -STUD - NO. OF 16D COMMON NAILS - (ENDNAILED 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 2 2 3 3 3 4 AMERICAN FOREST & PAPER ASSOCIATION DEMOLITION NOTES: 1. CONTRACTOR SHALL VISIT THE SITE TO VERIFY AND BE FULLY AWARE OF EXISTING CONDITIONS PRIOR TO START OF WORK. CONTRACTOR SHALL IDENTIFY ALL EXISTING ITEMS OF WORK SCHEDULED TO REMAIN OR SALVAGED FOR REUSES. 2. ALL DEMOLITION WORK SHALL BE PERFORMED IN ACCORDANCE W/ STATE & LOCAL REGULATIONS. CONTRACTOR SMALL SECURE AND PAY FOR ALL REQUIRED DEMOLITION PERMITS. 3. COORDINATE ALL DEMOLITION OPERATIONS W/ OWNER FOR SHUTDOWN PERIODS & SEQUENCES OF WORK. ARRANGE W/ OWNER &/OR APPROPRIATE UTILITIES FOR SERVICE SHUTOFFS BEFORE BEGINNING DEMOLITION OPERATIONS. PROVIDE TEMPORARY DUST PARTITIONS, BARRICADES, AND PROTECTIVE ENCLOSURES TO PROPERLY SECURE, ISOLATE, AND WATERPROOF AREAS OF WORK AND EXISTING AREAS AND ELEMENTS TO REMAIN. THE CONTRACTOR SHALL PERFORM THE WORK OF THIS CONTRACT IN A MANNER THAT CAUSES NO DISRUPTION TO THE CONTINUOUS OCCUPATION, WHEN AND WHERE APPLICABLE, OF THE BUILDING & SITE FOR THEIR INTENDED PURPOSE. 4. REMOVE ALL DEMOLISHED MATERIALS IN ACCORDANCE WITH LOCAL REGULATIONS. 5. IT IS NOT THE INTENT TO SHOW EVERY PIECE OR ITEM TO BE REMOVED IN THE DEMOLITION WORK. PLUMBING, ELECTRICAL, AND OTHER WORK RELATED TO A WALL, OR OTHER AREA SCHEDULED FOR DEMOLITION AND REMOVAL, SHALL BE PERFORMED WHETHER NOTED OR NOT. 6. THE EXTENT OF ALL SPECIFIC DEMOLITION WORK SHALL BE COORDINATED W/ THE CONTRACT DOCUMENTS. 7. CONTRACTOR SHALL PATCH/REPAIR/REFINISH, AS REQUIRED, ALL SURFACES EXPOSED BY DEMOLITION WORK WITH MATERIALS & METHODS TO MATCH FINISH AND MAKE FLUSH W/ EXISTING ADJACENT SURFACES. WORK SHALL INCLUDE ALL LABOR & MATERIALS ON ALL SURFACES REQUIRED TO RENDER SUBSTRATES ACCEPTABLE TO, RECEIVE NEW FINISHES SPECIFIED IN ACCORDANCE W/ MANUFACTURER'S SPECIFICATIONS. 8. CAP & REMOVE ALL ABANDONED ELECTRICAL, PLUMBING, MECHANICAL, AND FIRE PROTECTION ITEMS BACK TO SOURCE. 9. WHERE EXISTING FINISHES ARE INDICATED TO REMAIN AS BASE MATERIAL SURFACES FOR INSTALLATION OF NEW FINISH, REMOVE ALL PROJECTIONS AND VOIDS AND SECURE OR REMOVE AND REPLACE ANY EXISTING LOOSE OR OTHERWISE UNSUITABLE SUBSTRATE MATERIAL. I Ill 11 ai h Lh- 'c t s dAl rr architects interior designers builders 299 WHITE'S PATH SOUTH YARMOUTH, MASSACHUSETTS, 02664 tel (508) 362 - 8883 (508) 760 - 2800 fax (508) 760 - 5800 WWW.ERTARCHITECTS.COM PROPOSED CONDITONS AT* 9 VICTORY LANE SOUTH YA R M OU TH , PROJECT # 421022 2022 ERT ARCHITECTS, INC. THE DRAWINGS AND ALL OF THE IDEAS, ARRANGEMENTS, DESIGNS, AND PLANS INDICATED THEREON OR REPRESENTED THEREBY, ARE OWNED BY AND REMAIN THE PROPERTY OF ERT ARCHITECTS, INC. NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE, EXCEPT WITH SPECIFIC WRITTEN PERMISSION OF THE FIRM ERT ARCHITECTS, INC. THESE PLANS ARE NOT TO BE USED FOR PERMITTING OR CONSTRUCTION PURPOSES UNLESS STAMPED & SIGNED WITH AN ORIGINAL ARCHITECT'S STAMP AND SIGNATURE & MARKED AS "PERMIT SET" OR "CONSTRUCTION SET". REGISTRATION REVISIONS DATE: REVISIONS: ISSUED FOR: DATE: b 9 PROJECT TRUE SCALE: 1 /4"=V-0" 0 1 2 4 8 UNLESS OTHERWISE NOTED. SHEET NO. A*2 TOTAL NUMBER OF SHEETS IN SET: 2 THIS SHEET INVALID UNLESS ACCOMPANIED BY A COMPLETE SET OF WORKING DRAWINGS