Loading...
HomeMy WebLinkAboutEngineer PlansGENERAL NOTES: ACCESS COVERS MUST BE WITHIN 9' M/NlMUM. I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION 6OF FINISH GRADE � 3' MAXIMUM COVER OF THE SEWAGE DISPOSAL SYSTEM ONLY. FIRST 2' TO BE LEVEL, MIN 2' OF PEASTONE 2. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL 47 PVC 3/4' - ! I/2' D/A. CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL SCHEDULE 40 _ a�-- ;1 T2. , L%WASHED STONE BOARD OF HEALTH REGULATIONS. 93. 0 / $ 90.5 94 0 BAFFLE OUTLET 3-500 GAL LEACHING CHAMBERS 3. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER iD W/4' STONE AROUND. 12.8'X 33.5'X D-BOX 2' AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER /O' MIN. -1500� GAL THAN 3 ' IN DEPTH SHALL BE CAPABLE OF WITH- SEPTIC TANK 6' CRUSHED STONE BASE' STANDING H-20 WHEEL LOADS. PROF I L E : NOT TO SCALE 4. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR APPROVED EQUAL. 5. BEFORE CONSTRUCTION CALL 'DIG -SAFE". 1-800-322-4844 AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. \ 6. VERTICAL DATUM IS: ASSUMED \ \ \ 7. FOR BENCH MARKS SET. SEE SITE PLAN. 8. EXISTING CESSPOOLS TO BE PUMPED DRY AND BACKFILLED. i i t 30-------------- 6�----- u, \ 97 �1 \ OAK WI RE FENCE - CESSPOOLS t� • \ `� d T 13 _ __\ !� , 12' OAK 15911 + S.F. ��jj> � � 96.4 1500 @ALA p \ t \ B' OAK v t sEP IC TANK 1.4.10 i6' OAK m m �� 3-500 WAL J T N ~\2 OAK \t ` LEACH/NO CNAkBER: t \ TWN B' MAPLES O -+ \ \\ \ W/4• STONE AROUN! 1 T• OAK � ; \\ TEST` IT t r'" / �?( 'o n \ 14' OAK r n \ 9369 � � OAK��� 14' OAK \ +95.4 S' OACh K O cw Qt /4' OAK \ o om L Ut. U5 NIA;' �3 14. OAK ` �o YL i rAV6D / \ 1 • 1 I INVERT ELEVATIONS: INVERT AT BUILDING: __97.04 INVERT IN SEPTIC TANK: 94.0 INVERT OUT SEPTIC TANK: 93. 75 INVERT IN DI ST. BOX: 9j. 0 _ INVERT OUT DIST. BOX: 92.83__ INVERT IN LEACH CHAMBER: 92. 5 BOTTOM OF LEACH CHAMBER: 90. 5 ADJUSTED GROUND WA TER : - N/A OBSERVED GROUND WA TER: N/A BOTTOM OF TEST HOLE #1. 85.5 N DESIGN CRITERIA: DESIGN FLOW: 4 BEDROOMS AT 1 0 G.P.D. PER BEDROOM EQUALS 440 G.P.D. NO.__GARBAGE GRINDER SEPTIC TANK REQUIRED: -A4-0-G. P . D . X 200% - 880 GAL. SEPTIC TANK PROVIDED: 1500 GAL, SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE - ( 5 MIN/INCH SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0 , 7_4 GPD/SF 440 GPD / 0, 74GPD/SF -59S. F. PROVIDED: 3-500 GAL__LEACHI NG CHAM8ER5 W/4 ' STONE AROUND, A-6I4 S.F. _ SOIL TEST PIT DATA mm INDICATES. �_ INDICATES PERCOLATION OBSERVED !49 TEST GROUNDWATER TPs 1__-- GRND EL. 95.5 G. W. EL . _N/A_ 0' HORIZON TEXTURE COLOR _-OTHER 9 DATE: SEP TEMBER 5. 1996 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE PER RATE:(_ 2 MIN/INCH TIC S Y S T E_" GD E S/ G /%/ N S CR O WE-L L R O,A O WE' S T YEA R "0 U T H. "A. PREP,ARE'O FOR 1 I \ 5 s7ocKADE 1 + 0 tt I ( 14' OAK ° 65 52 5' E `- , S T E P 11--114 A/ P L A T T 95.5 95.2 94.7 93.5 65.5 302 ELL /OT ROAD. CENTERV/LLE. A,A 02e532 u� s � � � � S C�1 L E : / 2 O SEP TEMBER 2 4 . / .9 9 DEC 0 2 1996 UP 9/93 0 1120 \\ -"' 0 10 20 40 �92 3 R O Ycxr 17Z0 u jv0r r 5 0 362 -� 132 �50�� 4 32 -5333 96-321 I FIELD:CFW/TAW CALC: SAH/CFW CHECK: CFW INC. FAMWOM EMIR