Loading...
HomeMy WebLinkAboutEngineer Plana SITE PLAN SCALE: 1" = 20' B.M.=100.00,(ASSUMED) SITE ON PK NAIL SET A-\\ "YARMOUTH" LOCUS NO SCALE X 102.70' ##12 BUCHANAN RD 102.9 ' 63-96 town water 103 CP O ##18 BUCHANAN RD 63-97 town water X 6 Rows of 9 Quick 4 plus low profile Infiltrator chambers with geo-grid below in 36' X 17 field. 0 `l O 0' 102.20 12 � r r � EXISTING INGROUND POOIL r r Top of Pool Wall, Elev= 102.7' r � r 102.70 X 1 2.90' LEGEND 103P u _W— Approximate location water Ilne -- -18 - Existing contour Prpump chambe9al. H-10 loading =�v Approximate Location of I Existing Leach Pit (to be pumped and backfilled) 101.70' X Denotes existing spot grade Test Hole -o- Utility Pole 1 I Existing SAS (to be removed) O O O Proposed 1500-gal H-10 Septic Tank Proposed contour F 102 �n or JOHN iv C 3589 �001]T' (-1'j 1 #67 COOLIDGE RD 1p1 U.P. �( :100.08' 63-93 Q' town water X 101.50' 102 X 101.90' O 'k 100.06' .��yE�PSt�-� •+ � gii O 10 5' �ED 1,9el3' 02.93 °DRIVEWAY:- = 50 ',,DRIVEWAY-..-'; 1.77,. 2.90' W.S. a� J 02.70' �m /EXISTING 102.50'w DWELLING // ,,,�': ' 0 First FI. Elev=103.04' X 101.00' gg 97' : �7 catch � basins 101.90' O �. O °s a e°°� 99.89, 100.00' _ 101.60' B.M. 10, Oyerh X 1OD.10' oassumed n PK se } "oo•.... t F/ec 52' of 2" diameter force main Te( ,,II 1 cob�e LOT 47 X 101.36' AREA=15,000± S,F 100 100.13 setbacK U . P ........ geptic 12p.0�' 161 ##79 COOLIDGE RD 45 mil liner at edge of stripout 100 54 town Taftrmouth Health Department 10' nlgi �, UV' LD Design Calculations APR 14 20B Number of Bedrooms: 3 Equivalent to 330 Gal./Day Garbage Disposal: Not allowed with this design HEALTH DEPT Septic Tank Capacity Required: 330 gpd X 200% = 660 Septic Tank Capacity Provided: Proposed 1,500-gal H-10 septic Tank Leaching Capacity Required: 330 gpd X LTAR= 446 SF Req'd Area LTAR for Class I soil at <5 min./inch = 0.74 gal/sq. ft. Proposed Leaching Structure: 17' X 36' X 0.28' Leach Field. Bottom Leaching Area Provided = 612 sq.Ft. Sidewall Leaching Area Provided = 0 sq. ft. Total Leaching Area Provided = 612 sq. ft. > 446 sq. ft req'd. Leaching Capacity Provided =612 sq. ft X 0.74 gal/sq.ft.=453 gpd. PROPOSED SEPTIC SYSTEM REPAIR PREPARED FOR BUY IT ALL, L.L.C. AT #73 COOLIDGE ROAD YARMOUTH, MA 04" INLET'POLYLOK SEAL' 1�® 12 in 10 in INV IN INV PUT _L J' 2 in 'CONCRETE COVER ( 30 in 04" OUTLET'POLYLOK SEAL' APPROVED o _ ,.r ...,., Date 7 HOLE H-20 DISTRIBUTION .y NOT TO SCALE GENERAL NOTES fU`� 1. ADDRESS: 73 COOLIDGE ROAD, YARMOUTH, MA 2. ASSESSOR'S NUMBER: MAP 63 PAGE 92. `j r{ DEPT. 3. DEVELOPER'S LOT: LOT #47. Ham' 4. TOPOGRAPHIC INFORMATION WAS COMPILED FROM AN ON THE GROUND INSTRUMENT SURVEY. 5. TOWN WATER IS PROVIDED TO THE SITE & SURROUNDING PROPERTIES. 6. NO WETLANDS ARE LOCATED WITHIN 150 FEET OF THE PROPOSED SAS. 7. REFERENCE PLAN: L. C. PLAN 25823—D PAGE 1. 8. UTILITIES LOCATED BY DIGSAFE. 9. THIS DESIGN PLAN IS TO BE UTILIZED FOR THIS SEPTIC REPAIR ONLY. 10. EXISTING SEPTIC COMPONENTS SHOWN PER AS—BUILTS ON FILE. 11. THE PROPERTY IS NOT LOCATED IN AN AREA OF CRITICAL ENVIRONMENTAL CONCERN. 12. THE PROPERTY IS NOT LOCATED IN A NATURAL HERITAGE AND ENDANGERED SPECIES PROGRAM AREA. 13. THE PROPERTY IS LOCATED IN A ZONE—X MINIMAL FLOOD HAZARD ZONE AREA. 14. THE PROPERTY IS LOCATED IN A ZONE —II AREA. PREPARED BY: A Perfect Environment L L C dba Geo-Cape Environmental Consultants 100 Independence Drive, Suite 7-623 Hyannis, MA 02601 tr- Tel: 774-238-1813 Email: aperfectenvironment® mail.com SCALE: 1 "=20' DRAWN BY: TWH 7 APRIL 2023 ;'. DATUM: ASSUMED FILENAME:73000LIDGE SHEET 1 OF 3 *NOTE: ALL PIPES ARE TO BE 4" SCHEDULE 40 P.V.C. EXCEPT THE 2" DIAM. SCH.40 FORCE MAIN 3 Existing Building 1 *NOTE: INSTALL TUF—TITE GAS BAFFLE OR EQUAL ON ALL OUTLET TEE ENDS. Top of SIDE VIEW Pump Chamber cover must be Septic tank covers must be at finished grade 6" below finished grade I Grade=i 02i Finished rode over system=2% slope PROPOSED 1500 GAL. SEPTIC TANK 6" OF 3/4"-11/2" STONE (typical) Thrust Block to be provided at change of direction in force main. 4811 (EFFECTIVE LENGTH) TOP VIEW Distribution Box Cover to be 6" 7 HOLE Below Finished H-20 Grade. \ DIST. 80 2„ — — L=52' Inv. elev.= 97.73' PUMP CHAMBER See detail on page 3 Pro osed Finished Grade EL 12' min. 36max vel 5=0.0 i Jft 10 �( 6" OF 3/4"-11/2" STONE INSPECTION PORT INFILTRATOR WATER TECHNOLOGIES QUICK 4 PLUS STANDARD LOW PROFILE CHAMBER 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. CONSTRUCTION NOTES GEOGRID (see detail on page 3) Finished grade over system=2% slope away LEACHING FIELD SAS LAYOUT grade 3.3" Facility Elev.-101.41' 45 mil liner Elev.=100.0C 5' (5' Min. required) Adiusted Groundwater Elev.=96.41' Scale: 1 "=20' A CORNER DWELLING TO CORNER TANK, PUMP CHAMBER AND SAS A-1 = 34'-10" B-1 = 30'-9" A-2 = 45'-0" B-2 = 21'-2" A-3 = 37'-2" B-3 = 33'-2" A-4 = 44'-0" B-4 = 26'-1" A-5 = 51'-3" B-5 = 30'-8" EXISTING A-6 = 85'-5" B-6 = 33'-9" DWELLING 1 O 0 0 O 0 t Contractor is responsible for Digsafe notification and protection of all underground utilities, site features and pipes. PERK TEST & SOIL EVALUATION The septic „tank and distribution box shall be set level on 6 of 3/4' —1 1 /2 ' stone. DATE OF TEST HOLE: FEBRUARY 23, 2023 Backfill should be clean sand or gravel with no Performed By. MIKE LEARY, T.L.H. EXCAVATION stones over 3" in size. Witness: JAY GARDINER, ASSISTANT HEALTH AGENT This system is subject to inspection during installation Percolation Rate: < 2 MPI IN C1 by Geo—Cape Environmental Consultants. The contractor shall install this system in accordance with Title 5 of the Massachusetts Environmental Code Frimpter Calculation and Local Board of Health Rules and Regulations. Reference Well: A1W-231 If, during installation the contractor encounters any Range: Zone E soil conditions or site conditions that are different Groundwater Conditions: Normal from those shown on the soil to or in the design, Current Well Data: February, 2023 g 9 Water Level: 25.8' the installer shall halt installation and immediately notify Adjustment: 2.6' Geo—Cape Environmental Consultants. Therefore adjusted depth to GW=102`31"= 71" No vehicle or heavy machinery shall drive over the = Elevation 96.41' septic system unless noted as H-20 septic components. All piping shall be 4" diameter SCH 40 PVC unless otherwise specified. No wells are located within 150' of proposed SAS. Provide 1 1,000—gal H-10 "Mono" Septic Tank, 1 1,000—gal H-10 "Mono" Pump Chamber and 1 DB-7 H-20 D—Box by Acme—Shorey or equal. Existing septic system shall be pumped and removed/backfilled. The designer is not responsible for undocumented septic components. The septic components shall be marked with magnetic marking tape for convenient re —location. The Contractor shall provide a minimum of 24 hour notice to the Designer and Board of Health for as —built inspection of the system prior to backfilling. Install 2" Schedule 40 PVC tee vertically on inlet of D—box. Install Zabel A1800 effluent tee filter or equal on septic tank outlet tee. GROU 1 Test Hole No. 1 DEPTH SOILS ELEV.' 102.31 0/A/E LOAMY SAND 10YR5 21o1.61 I Bw LOAMY SAND " 10YR5 6 99.65 71 C1 6 3. 102" SAND 0% GRAVE 2.5Y6/4 120" 92.31 VADJ. GW OBS. Gw PROPOSED SEPTIC SYSTEM REPAIR OF MQ ,� PREPARED BY: A PerFect Envirotoment LLC dba PREPARED FOR ,G Geo—Cape Environmental Consultants BUY IT ALL, L.L.C. E C t 100 Independence Drive, Suite 7-623 AT -�' Hyannis, MA 02601 e� " .� � � � Tel: 774-238-1813 73 COOLIDGE ROAD 9 �p Email: aperfectenvironment®gmaiLcom + SCALE: 1 "=20' DRAWN BY: TWH 7 APRIL 2023 YARMOUTH, MA �NlTAR�P� DATUM: ASSUMED FILENAME:73000LIDGE SHEET 2 OF 3 INFILTRATOR WATER TECHNOLOGIES QUICK4 PLUS STANDARD LOW PROFILE CHAMBER TYPICAL BED DETAIL SECTION VIEW (NOT TO SCALE) ESTABLISH VEGETATIVE COVER NATIVE BACKFILL 777 V.. 3411 EXTEND 1' BEYOND EXCAVATION INLET INLET 3-20r DIAM. ACCESS MANHOLES STEEL REINFORCED PRECAST CONCRETE PLAN VIEW 3-20' REMOVABLE COVERS Wet to —Uet ft Eg It + i W GEOGRID (ISI 14000 OR Tensar BX1100 OR EQUAL) 6 Rows at 17' THE ACCESS COVERS FOR THE SEPTIC TANK, UDI i f t Calculations (Septic To k OUTLET DISTRIBUTION BOX AND LEACHING COMPONENT 96.41-93.60= 2.75" in GW SHALL BE WITHIN 6" OF FINISHED GRADE. Fu=10.17 x 6.08 x 2.75 x 62.4 Ibs/ cu ft= 10,610 Ibs INSTALL ZABEL A1800 EFFLUENT TEE FILTER Weight of Septic Tank (empty) = 12,000 Ibs No uplift anticipated. OUTLET T lO._O. CROSS—SECTION END —SECTION TYPICAL 1500 GALLON H-10 SEPTIC TANK NOT TO SCALE 4,-7" (11` 'POLYLOK III BOOTS' ) 024" CONCRETE COVER 04" OUTLET ILYLOK III BOOTS' 1,000—GAL PUMP CHAMBER NOT TO SCALE *Use Acme—Shorey 1000—gal "Mono- Pump Chamber or equal. SIMPLEX SLIDE RAIL SYSTEM OR INLET INVERT ELEV.- 97.98' 74 GAL Reeerce 30' so• EXTEND 1' BEYOND EXCAVATION PROVIDE 24" C.I. `FAWE & CG.ER OWED —DOWN FOR .ECURM( OR EOUFi 1�f'xED GRADE ELEV. =Existing OUTLET IHVERf ElEV.-97.73' 31(8 WEEP HOLE ABOVE CHECK VALVE FREE2E PROTECTION) 2- SMNC CHECK VAUA—P-V-C. HIGH WATER ALARM ELOV.-95.a" PUMP ON ELEV.-95.72' PUMP OFF ELEV.-95.22' FLOOR PUMP CHAMBER ELEV.-93.?2' PUMP DETAIL Not 10 Scale PUMP NOTES & SPECIFICATIONS 1. PROVIDE 1 LIBERTY MODEL LE40 4/10 H.P. SUBMERSIBLE PUMPS CAPABLE OF PASSING A MINIMUM SOLID SIZE OF 2" DIAMETER, 115V, 1 PHASE OR EQUAL 2. USE LIBERTY NEMA0 SIMPLEX ELECTRIC CONTROL PANEL OUTDOOR MOUNTED W/VISIBLE ALARM OR EQUAL 3. PUMPS SHALL BE INSTALLED IN STRICT COMPLIANCE WITH MANUFACTURER'S SPECIFICATIONS. 4. ALARM SHALL CONSIST OF AUDIBLE SIGNAL & RED WARNING LIGHT TO BE INSTALLED ON BUILDING AND POWERED BY SEPARATE CIRCUIT FROM CIRCUITS TO PUMP. 5. AN ELECTRICAL PERMIT SHALL BE OBTAINED PRIOR TO INSTALLING ALARM AND PUMP POWER. 6. THE FORCE MAIN SHALL BE 2' DIA. SCH 40 PVC WITH THRUST BLOCKS INSTALLED. AS NECESSARY. 7. INSTALL SIMPLEX SLIDE RAIL SYSTEM or STAINLESS STEEL PULL CHAIN Uplift Calculations (Pump Chamber Fu=8.25 x 5.42 x 3.01 x 62.4 Ibs/ cu ft=8,399 Ibs Weight of Septic Tank (empty) = 8,200 Ibs Weight of Soil =5.42 x 8.25 x 2.82 x 9Oibs/ cu ft=11,349 Ibs S.T. & Soil=19,549 lbs. > 8,399 Ibs of uplift. No uplift anticipated. PROPOSED SEPTIC SYSTEM REPAIR ,��IIQF PREPARED BY: A Perfect Environment LLC PREPARED FOR G Geo—Cape Environmental Consultants BUY IT ALL, L.L.C. E 100 Independence Drive, Suite 7-623 AT ftl Hyannis, MA 02601 Tel: 774-238-1813 Email: gharr88®hotmail.com #73 COOLIDGE ROAD •^ { DRAWN BY: TWH 7 APRIL 2023 YARMOUTH, MA FILENAME:73OOOLIDGE SHEET 3 OF 3