HomeMy WebLinkAboutBLDE-22-001462 plans NOTE:Service Panel does not contain center fed Mein Breaker: PV MONITORING SYSTEM / / NON CENTER IOOA PV DISTRBT.PANEL MAIN CrS ___J 100A,120/240v, Were,Loony Labeled Clammed MA SMART NEMA 3R to or Len tram NMb Meter GENERATION METER INSTALL 15A PV 3M t2a24Jv 400 KW 12024EV MAIN METER L B / Non FueM AC D'recmnect BUNPOWER TRUNK CABLE �j NEMA 3R EXISTING SUNPOMN C PVN7RE INSTALL 20A PV �'�Y/ j INSTALL IOA 2P CB(PV) `' taOA GWN 2-POLE CB INSTALL AT OPPOSITE k" `f 6ERVICE FR IN H I. �7 Q END OF BUS FROM pµEL N+, MAINFEEDERCB 1j�. ,2n,w, CONTRACTOR' C7 \ 1p.3w r(roc r NEMe'" i(ffi9/ T-® Solar 11 ERaraV Y Address:771 WaWrgton St. e C e Ai G - .... g ✓ Auburn,numberPhone (�B784396 5i2t LmemW8610672 rct ~ ^ (2)010 AWG THWWTHWN-2 _ -L_ (1)OS MVO GND ' ""' .. - 3M"EMT 15 FEET 12 SUNPOWER 335 WAIT MODULES (2)01OAWG THWN/1HWW2 (3)atOAWG TMWNRHWN-2 (3)p10AWG THWN/TMWN- (3)YtOAWG THWNRHWN- (� 12 SUNPOW£R INTEGRATED MICROINVERTERS (1),YB AWG GND (1)*B AVVG MT2GND (1)08 AWG GND 2 �'e.'rENEaRG F (1)08 AVM OND 3/4"EMT 2FEET (E)GROUNgNG 3/d•FMT 10 FEET 3r4"EMT.2 FEET 3r4•EMT 2 FEET PV ARRAY RATING BRANCH CIRCUIT WIRE SIZE CALCULATION Number ModulesBRANCH CIRCUIT 12 Type Sunpower AC 335 Watt SPR-X21-335-BLK-E-AC Number OF Microinverters in Circuit Sunpower 335 Watt AC 12 Number Microinverters Type Factory-intergrated SPR-X21-335-BLK-E-AC 12 Microinverter Maximum Output Current(A) Microinverters (240V) 1.31 Location Watts STC,(335Watts/Module)12*335=4020 Branch Circuit Total Current(A) ELECTRICAL 1-LINE Array Currents I-SC I N/A 1,4 12*1.31*1.25=19.20 I-MP I N/A A Breaker Size Per Branch Circuit(A) DIAGRAM Module Voltage V-OC N/A V 20 V-MP N/A V FROM!BOX TO MAIN PANEL Total Number Of Microinverters ENGINEERING 12 I Total Amps From AlI Microinverters (A) 12*1.31=15.72 Consider Continuous(A) Drawn by Naw9aow aelrc.ro Temp.Derate Factor(0.91 at wall of the Building)(A) 15.72*1.25=19.65 GATE°fl'/ 19.65/0.91=21.59 Wire Size from NEC Table 310.15(6)16I _ 1I m. Ambiend Tem Factor Per NEC Table 310.15(b)(2)(a) 10 AWG 0.91I MAIN PANEL ;. l PV Backfeed Breaker Size(A) _ 20 Main Breaker(A) 100 I Main Bus Rating(A) I 100 Total Amps On Bus(A) 120% 100+20= N • o• 'I�, (.' • LEGEND tA�. �; t; MM Main Meter MSP Main Service Panel W E 'gr PVS PV Sub Panel no so• .' PVS6 PV Monitoring System / :a i i AC AC Disconnect MA MA Smash �� ...ter. .ter 0a. y 4•'t, Al+\� Generation Meter t • v• 5� \ .RO'ERT INE SCALE: 1/16"=1'-0" , • „ 1 ' . Vi▪ a. � y CONTRACTOR •r 'Y �` %° Solar Wolf Energy "••. + C. e Address:nt wawrgtoa EL • ! � rt ♦ . . .7 '7" . ♦ 1 Auburn,MA a15a1 . . . . . , ,� Phone number:(888)6784396 y •:.jv' '✓r `` e . .... . . . . . IL�S�, License,:a-gram o • • .. �t. SOLAR F N . r ` " • • • „ - YTl t ENERGYbw. 71111' .Q4 '+ A_ . . . V 0r \`am\ 1Vg^. I . .e.Ws y du ji H • • • • � 93'- / PROPERTY PLAN • • • • ' X ''' i e� a� ENGINEERING. . VP V. . `/ �(�a� Drawn by:Nmw�.aglneeanc.la I \ . . . 9'`VP DAreorvzazort 1 Vr Marcy Cohen . . ... �/ nwwra� "'/ i2 St Andrews Nay • . . South Yarmouth,MA 02664 C I PV SYSTEM II AS INDICATED PV 4.0 X X-Series:X21350-BLK I X2,-33591K I X20.321-BLN SUN POWER' X-Series:X21.350-BLK I X21-335-BIM I X20-327-BLK - CONTRACTOR SunPower`Residential Solar Wolf Enersw AC Module Address:TiWaeMpon 6t. Auburn MA 01501 Phone number:(888)BTtN396 3u ! l ally foruse wrh,tir SunFowv E , 1-only 4sY LieaW:&9408rz -,wronde ,/..,Berea d s>o ao...er. n �,ENERGY uSOLARW LF OJl �� .. MaximumPower.Minimalist De LTA, Highest Lifetime Energy and Savings. Fundamentally Different J g And Better. 35�,o,...,:• 2aeaaa+enru.3aN . a Tie Sn.72am 0.,eo•`S,,,Cell r...,dw•.+w ^ Best Reliability.Best Warranty - N.,tl — �Vl MOLE DATA SHEET E„e, GNGINCCG2INC Drawn by:A412021 needncio . B ' ... '--: _ _ DATE:08/2Y1021 © SUNPOWER' 12 St Andrews Way South Yamnulh,MA 02664 �,w,.� PV SYSTEM AS INDICATED D 6.0 • sPEGASUS A BETTER DAY ON THE JOB COMP MOUNT ()LAW Z.(*.Nutt NI* CONTRACTOR COMP MOUNT sweeter raft. gishape-eland,°° teased,of Solar Wolf Energy twang and P9411,0n Addreas-771 Washington SL num,ro,oe, Auburn,MA 01501 pern ntee Phone nurnber(888)878-43913 License*,B940672 Sr 3-pwce deems : '• 4 con.),ley to eetwed f r ,for rased,nstallaeon , .0 OENEARWCIF GY I.U. L , V 1/4,>?It. o•,ws.,.....,11 novefrawe s .„ ..., .. . „ . . Ercapudating design , 1141/01. tames tee no.seal 1 0 9'above root deck i 1 I I (Mame.Hash,ng with devated cone—No prem,nts or deckdevel EPOM washers to tad tZr 1 ‹.....,.e,............„.2 1 Spoons... C..,Mos.InsteAl Km .:1 rso co ,SCR L. SKR C i WATERTIGHT FOR LIFE i to.T (1...iltst Pegasus Solar,Comp Mount tr.a toot effect,hmhqu- al,ty matron for me installations on composition a/angle roofs px 0„.„y,„, ,cod, Designed to last decades,the one-plete flmning mth elevated cone romns there o ornply nothing to fail s' -"r17r:i2a.-r, 55 Lag,11PCM v.'s.. ..CIDNI vs.,IWO I Iss Ilett ATTACHMENT Oletk.I..disinters, DATA SHEET CIO 25 year Wartanty Superor Waterproofing ,i,,F rype CcuryscsMon Slogle AP 44' ' 'BC ASCEiSCI 7.10 oV,Z36 fts,l,',STA ENGINEERING NI Drawn by.New(lencineerine in DATE 08/24/2021 Code Compliant 41111.0, Alltn eDne Kd Packages, ...soreo. 21 Morey Cohen IS , 60.5 PPf Pall. , Prernss 12 St Andrews Yew South Yarmouth MA 02864 IPV SYSTEM II AS INDICATED I ID 8.0 • ACCPREP CERTIFICATE OF LIABILITY INSURANCE I DATE(MM/DD/YYTY) 08/17/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Leib Insurance MANE: PHONE 508-792-0411 FAX 537 Park Avenue E-MAIL EMI' (Arc,No): ADDRESS: Worcester, MA 01603 INSURER(S)AFFORDING COVERAGE NAIC INSURER A:NAUTILUS INSURED SOLAR WOLF ENERGY INSURER B 771 WASHINGTON ST - INSURER C: AUBURN MA INSURER D: INSURER E:LIBERTY MUTUAL INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS' CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POUCIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUER LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER (MMIDCDY/YYYY) (MIMI OUCDDI YYYY) Leers )( COMMERCIAL GENERAL UABILfrY EACH OCCURRENCE $ 1,000,000 CLAIMS MADE X OCCUR DAMAGE EES(Ea occurrence) $ 100,000 A N NN1207723 06/08/2021 06/08/2022 MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 GEN L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY 1 1 JE LOC PRODUCTS-COMP/OPAGG E 2,000,000 OTHER: S AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ ANY AUTO (Fa accident) BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ HIRED NON-OWNED PROPERTY DAMAGE AUTOS ONLY _AUTOS ONLY • (Per accident) $ UMBRELLAUAB —OCCUR EACH OCCURRENCE S EXCESS UAB CLAIMS-MADE AGGREGATE S DED RETENTION$ WORKERS COMPENSATION S AND EMPLOYERS'Lwow), Y/N S ATUTE ER AM/PROPRIETOR/PARTNER/EXECUTIVE OFFlCER/MEMBEREXCLUDED? n N/A E.L.EACH ACCIDENT $ 1,000,000 E (Mandatory in NH) WC2-31S-614936-020 08/10/2021 08/10/2o22 If describe'under EL DISEASE•EA EMPLOYEE S 1,000,000 DESCRIPTION OF OPERATIONS below EL DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION TOWN OF YARMOUTH 1146 RT 28 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN S YARMOUTH MA 02664 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORS -a TTIVE ACORD 25 2016/03 ©1988-2015 ACORD CORPORATION. All rights reserved. ( ) The ACORD name and Iogo,are•registered marks of ACORD The Commonwealth of Massachusetts Department of Industrial Accidents '� `,,��'� Office of Investigations 1s—? Lafayette City Center - ; 2Avenue de Lafayette, Boston,MA 02111-1750 www.mass.gov/dia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name(Business/Organization/Individual): Solar Wolf Energy Address: 771 Washington St City/State/Zip:Auburn, Ma 01501 Phone#: 508-839-2222 Are you an employer?Check the appropriate box: Type of project(required): 1. ►:4 I am a employer with 6 4. El I am a general contractor and I employees(full and/or part-time).* have hired the sub-contractors 6. 0 New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. 0 Remodeling ship and have no employees These sub-contractors have 8. El Demolition working for me in any capacity. employees and have workers' [No workers' comp.insurance comp. insurance.$ 9 ❑Building addition required.] 5. We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.]t c. 152,§1(4),and we have no employees. [No workers' 13.2]OtherSOlar Installation comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Leib Insurance Policy#or Self-ins. Lic.#: WC2-31 S-614936-020 Expiration Date: 08/10/2022 Job Site Address: 12 St Andrews Way City/State/Zip:S. Yarmouth, Ma 02664 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains at enalties of perjury that the information provided above is true and correct. Signature: Date: 9/13/2021 Phone#: Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(check one): lDBoard of Health 20 Building Department 30City/Town Clerk 4.0 Electrical Inspector 5E1Plumbing Inspector 6.DOther Contact Person: Phone#: :: OMMONWEALTH OF M A CHUB . l DIVISION OF PROFESSIONAL LICENSLIRE BOA t ''44F ELECTRICIANS ' ... ISSUES THE FOLLOWING LICENSE -`' REGISTERED MASTER ELECTRICIAN KYLE ZUIDEMA SOLAR WQLF.ENERGY, INC 99 DUDL:EY RD SUTTON, MA 01590 22593 ► 0?/31/2122 726517 LICENSE NUMBER EXPIRATION DATE SERIAL NUMBER '- ~' i ,, '� •; bra - , n mixer s. rr , SunPower° X21 -335-BLK-D-AC 1 Residential AC Module Series Design-Driven Advantages • #1 module aesthetics and efficiency' ©2 1 • Unmatched module reliability' • No electrolytic capacitors �� - SERIES • 25-year Combined Power and Product Warranty w • California Rule 21 Phase 1 compliant Maximize Value for Roof • Size system for roof, not string inverter • Optimize performance of each module Expand Deployment Options • Complex roofs and partial shading • Small systems Optimize System and Installation Efficiency • System expandability SunPower''AC modules,which include a factory-integrated SunPower Simplify& Speed Installation microinverter, provide a revolutionary combination of high efficiency, high • Factory-integrated microinverter • Robust,double locking AC connectors reliability,and module-level DC-to-AC power conversion. Designed • Design flexibility offsite and onsite specifically for use with SunPower InvisiMountT and the SunPower • No DC string sizing process Monitoring System,SunPower AC modules enable rapid installation, best- • Fewer installation steps than competing systems in-class system aesthetics,and intuitive visibility into system performance. • Intuitive commissioning All this comes with the best Combined Power and Product Warranty in Component of Complete System the industry. • Built for use with SunPower®InvisiMount'M and the SunPower Monitoring System(PVS5x) Grid Support Utility-Interactive Smart Inverter • Superior system reliability and aesthetics SunPower's new Type D AC module is UL tested and certified to UL 1741 SA and provides advanced smart inverter functions. SunPower Type D AC �,. modules are fully compliant with the California Rule 21 Phase 1 1�}jet requirements, and the Rule 21 grid profile is easily set during L. commissioning with SunPower PVS5x monitoring hardware. sunpower.com u_ _ SUNP WER® { SOLAR WOLF ENERGY inc. 771 Washington Street Auburn,MA 01501 Office 1: (888)878-4396 Office 2: (508)839-2222 Owner Authorization Form We the undersigned, hereby authorize Solar Wolf Energy Inc to act on our behalf in all manners relating to the installation of a photovoltaic system at the location 12 St Andrews Way South Yarmouth, MA 02664 This includes but is not limited to financing paperwork, interconnection documents, building & electrical permit applications, applicable rebate applications, etc. This authorization is valid only for items pertaining to the installation and commissioning of a solar power system to be installed by Solar Wolf Energy Inc. Signed under the pains and penalties of perjury. 06/29/2021 Signature of Owner Date Doc ID:039f38a554ac317324bb661f2f42e980fbd50a1b Customer: Marcy Cohen SOLAR WOLF Address: 12 St Andrews Way ENERGY inc. South Yarmouth, MA 02664 System size: 4.02 kW Yr 1 Production: 4,456 kWh Designer: Solar Wolf Energy Site Assessment Date: July 16th,2021 gym. 1� f0A, /11 1111,/ It powered by aurora GENERAL NOTES SHEET INDEX CONTRACTOR 1. All electrical materials shall be new and listed by recognized SITE MAP&PV LAYOUT PV 1.0 Solar Wolf Enemy electrical testing laboratory ELECTRICAL 1-UNE DIAGRAM_PV 2.0 Address:771 Washington St SOLAR,.ans Custom made equipment shall have complete test data submltted Adwm.MA 01501 �+ Y. . Phoby the manufacturer attesting to its safety SYSTEM LABELING DETAIL PV 3.0r `•s'G G 2.Outdoor equipment shag be NEMA 3R rated or equivalent PROPERTY PLAN PV 4.0 License ee: teael67&13ge r 3.All metallic equipment shag be grounded ATTACHMENT LAYOUT PV 5.0 Lkmaea a-9goSn 4.Contractor shall obtain electrical permits prior to installation any MODULE DATA SHEET Owner shall coordinate all inspections,testing commissioning and D 6.0 Mar Cohen Property Address: 12 St Andrews Way South Yarmouth,MA 02864 acceptance with the client RACKING DATA SHEET p 7.0 utility co.and city inspectors as needed. Property Type: Single Family Residence ATTACHMENT DATA SHEET D 8.0 Parcel Number: 5.The electrical contractor shall verify the exact locations of service M:0080 8:00097 points and service sizes with the serving utility company and MONITORING SYSTEM DATA SHEET D 9.0 Drawn by: NewQengneennc.io comply with all utility companies requirements. Data: 6.Drawings ere diagrammatic only,muting of raceways shall be 08/242021 option of the contractor unless otherwise noted and shag be GOVERNING CODES VICINITY MAP(SCALE:NTS) coordinated with other trades. THE INSTALLATION OF SOLAR ARRAYS AND 7 Ifthe roof material or the roof structure not adequate for PV installation,call the engineer o/recoMpdM to installation.The PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH contractor is responsible to verify that the roof is capable of THE FOLLOWING CODES: withstanding the extra weigh. • 2017 National Beetroot Code 8.If the distances for cable runs are different than sham,the 2015lnteme0onal Residential Code contractor shag notify the electrical engineer to validate the wire • 2015 International Building Code - size.Final drawings will be red-lined any updated as appropriate. 2015 International Energy Conservation Cod .1 y«a `"y 9.Whenever a discrepancy in quality of equipment arises on the • 2015 Mechanical Code drawing or specifications,the contractor shell be responsible for AS ADOPTED BY THE STATE OF MASSACHUSETTS providing and mstalgng all materials and services required by the ALL OTHER ORDINANCE ADOPTED BY THE �.a""'„" ` :.. strictest conditions noted on the drawings or in the specifications LOCAL GOVERNING AGENCIES „r � to ensure complete compliance any longevity of the operable system requited by the engineer of record. PHOTOVOLTAIC NOTES: SYSTEM RATING r ,F 1. Rooftop mounted photovoltaic panels end modules shall be tested. DC 4.020KW STC listed and identified by recognized testing laboratory AC 3.702KW STC 2.Solar system shag not cover any plumbing ormechanical vents ;,, 3 Moduleunlesss and cldngh sitatmdumsaha/lbegrounded SATELLITE VIEW(SCALE:NTS) leaareadngnaamregreed ground. EQUIPMENT SUMMARY 4.Removal of an interactive inverter or other equipment shag not • disconnect the bonding connection between re grounding 12 SUNPOWER 335W AC MODULES e electrode conductor and the photovoltaic source and/or output WITH INTEGRATED MICROINVERTERS circuit grounded conductors. 5.All PV modules and associated equipment end wiring shall be protected from physical damage. ELECTRICAL INFORMATION 6.Live parts of PV source circuits and PV output circuits over 150v to ground shall not be accessible to other than qualified persons EXISTING white energized. MAIN SERVICE PANEL BUS SIZE:100A1 7.Inverter is equipped with integrated DC disconnect,thus providing MAIN SERVICE BREAKER SIZE:100A - ground fault protection MOUNTING SYSTEM:INVISIMOUNT 8.All conductors shell be copper and 75 deg rated BUILDING INFORMATION 9.A single conductor shell be permitted toha used to perform the - multiple functions of do grounding,AC grounding and bonding between AC end DC systems. CONSTRUCTION TYPE:V-B 4" 10.Non-current carrying metal parts of equipment shell be effectively OCCUPANCY:R3 bonded together Bond both ends of raceways. Uiy;'.'.' ROOF:Comp.Shingle Rafter 2 x 8©24.0.C. x. SOLAR MODULES INDEX 'sot 12 SunPower MM (E)Main Meter Model#X21-335-BLK-E-AC MSP(E)100AMain Service Panel �' \� MICROINVERTER pyS (N)100A PV Sub Panel 1 /�; INVERTER TYPE:Micro 9 Sys team ! 12 FACTORY-INTEGRATED PVSS..(N)PV Monitoring S team W � E Model#X21-335-BLK-E-AC(240V) AC (N)30A AC Disconnect 2 c �- MA (N)MA Smedh GN)Jun ti Meter ,7g (N))MA Sn Box S - EMT Conduit t,PCit EMT Conduit Setback SCALE: 1/8"=I-0" CONTRACTOR Solar Wolf Energy Aeere.::7n alo we.la, n St ��'e. Auburn MA 01501 O / P bryPhone freeumber meat 8784396 Lice/ 672 �Ey �A,‘\'\/ IL ;,-".4\../ k* 47 6/ w. /� .44 40 Je i1` � SITE MAP 3 PV r LAYOUT So1ar PV array12-SunPower 335W ModulesGNGINCCG2INC 12-Bonin:30rDegerters Dnen by.New0enyneedecio ` ePntabo:Deg DATE:08W2AR021 • Orienta0on:136 Deg _• PVS C, Mercy Cohen S• M12 st Andrews S Y South Yarmouth, 02664 PV SYSTEM AS INDICATED NOTE: Conduit in attic shall PV 1.0 be minimum 18 inches from roof sheeting Site Assessment Customer: Marcy Cohen Address: 12 St Andrews Way South Yarmouth,MA 02664 f, Component List Manufacturer Model Quantity Sunpower Corp. SPR-X21-335-BLK 12 Enphase Energy Inc. IQ 7+ 12 . * 41/‘11 i tF Notes: powered by aurora , art V^` . . .- e F w �- it ., rti, Nam , �:�s i ' -, - P y f•¢ SunPower® X21 -335-BLK-D-AC I Residential AC Module Series AC Electrical Data3 IEEE 151Ia 2014' LA Rule 21' SRD Profile (default settings) min./nom /max --- n In./nom , It i Frequency(Hz) 59.5/60.0/or 58.5/60.0/60.5 Power Factor 0.99/ 1.00/ 1 00 0 35 lead./ 1.00/0.85 lag. ±169 Var Reactive Power Volt-VAr Voltage @240 V 211.2/240/264 V g @208 V 183/208/228 V @240 V 1.33 A Max.Current @208 V 1.54 A DC/AC CEC Conversion Efficiency @240 V 95% @208 V 95..5/o @240 V 12(single phase) Max.Units Per 20 A Branch Circuit @208 V 10(two pole)wye I Power 320 W,320 VA No active phase balancing for phase installations J DC Power Data Warranties and Certifications SPR-X21-335-BLK-D-AC SPR-X20-327-D-AC ( Vtarr�,rtt • 'S-year limited power warranty Nominal Power (Pnom) 335 W 327 W l • 25-year limited product warranty Power Tolerance ° +5/4 o ILL listed to UL'1741 SA g y +5/ /o Avg.Panel Efficiency' 21 0% 0 °� SRDs_IEEE 1547-2003,IEEE 1547a-2014,CA fi Temp.Coef.(Power) -0-29%/°C i Rule 21 Phase I Three bypass diodes I • PV Rapid Shutdown Equipment Shade Tolerance • Integrated module-level maximum power point • Equipment Grounding tracking • UL 6703,UL 9703 Connectors and cables (load break disconnection) Tested Operating Conditions • UL 1 741 AC Module(Type 2 fire rating) I Operating Temp. -40°F to+185°F(-40°C to+85°C) Certifications Enables installation in accordance with: Max.Ambient Temp. 122°F(50°C) i • NEC 690.6 Wind.62 psf,3000 Pa,305 kg/m2 front&back • NEC 690.12 Rapid Shutdown(inside and Max.Load Slow 125 psf 6000 Pa,61 I kg/m2 front sli l outside the array) Impact Resistance I inch(2 5 mm)diameter hail at 52 mph(23 rizisq • NEC 690.15 AC Connectors,690.33(A)-(E)(1) FCC and ICES-003 Class B Mechanical Data When used with InvisiMount racking(UL 2703): Solar Cells 96 Monocrystalhoe Maxeon Gen III - Integrated grounding and bonding High-transmission mission tempered glass with anti- e rated Hi h-transmiss Class A fir � refl Front Glass — — g ___ __ -- -.I PID Test Potential-induced �egra0ation free i Environmental Rating Outdoor rated , II Frame Class 1 black anodized(highest AAMA rating)- s [28Q?�] Weight 47 5 lbs 120.E kg) 4_ g) Recommended Max 3 In.(33 mm) — 1107mm L, ,■•• e Ts- 1Moodie Spacing ��� ET [43.6 In] ,:■• 1046mm EG t 10I ill o r p I hotor`�c dale s n ed 1 1 �. 1i� [4121n] t - I r r l ii i,tl t ilit rite ❑ di r tit,'el yr ito - S eb l n F out .1 i' 'r t igt t Isi r e i d t firer i re tested t srpe AJ et I tt o a r o ijlr 30 mm [12 In] I — � --" � �t i t t r i 1'� i 1 t'.d e ttrr et lit c ttir g pikl °t 1 i r. � *-- kMCaY �r _ amACINE mr 1556 mm ►as :t. -i.id7, I. sr i. ui.dial A.tl i.> > t� �- "lit r+liar rardard. [6131N-- EQUIPM�0ppi1iR'r , �r mamre+r O\ ,car i r 1 1 of-a All D ^;keg- t 11h 1 i 4i e.d..itt it The 1-4441e. LISTED WWD Luse 1mi t...ndinsrall iiorIrStta.a:4s131 details- Module fire Performance:Type 2 e o,.,, itpetyrerco .•tart.if 'pie Teter,r,ee n t'Il ee,tker zei ;ore deride see..titer deu del 4sleeet ww ,ti-unpowci i 01Jdatastteets. �� � � SUNP WER® Page 1 of 1 ° Chris Savasta • From: "Alisha Vasquez"<Alisha.v@solarwolfenergy.com> Date: Monday,August 16,2021 2:04 PM To: "Insurance for COI"<CSavasta@leibinsurance.com> Subject: COI request Hey, Can you send us an updated COI for Town of Yarmouth 1146 Rt 28 S Yarmouth, Ma 02664 Thanks! Alli Vasquez Solar Wolf Energy • Direct: (508) 538-9432 Main: (888) 878-4396 www.sol arwol fenergy.coal SOLAR WOLF 9 °k - 1.1 I1tC. Email-Signature.png 8/17/2021 r ettatir.: ..11116 * Residential and Commercial PVS6 CONTRACTOR ' Residential and Commercial PVS6 h 0 'AVA,V. 111 ) Solar Wolf EneraV Address.771 WeeNngton St Auburn,MA 01501 Phone number(8M3)1378-4396 Deana:8440672 SOLAR WOLF 555 ENERGY ingleal•:47 • - .'a MONITORING SYSTEM DATA SHEET r ENGINEERINC Dram by Nekv@engineednan, FCC ID 8058129027 E503346 DATE 08/2412021 Marty Cohen SUNP WER' South Yarmouth,MA 02664 SUNPWER' PV SYSTEM AS INDICATED D 9.0 4,#-Av-it.-t_gtAtvtg-z-4--,-*,,,ir,%---2.-- ",WlWt.V., *,7*.1,,s-t,-.----.-----'- Plr. -4"-'*--.:5*-t4-4-.. Z‘:l',.',.tt-l-F.i'-.`,-''''.-.l. '7,-'-i-,,,7f'1.t.liti-,----*-tl- -,!:--,,o-..': .l-,__------ . , ,. t'_-.V-kt--.41-''-:-.4,41:44:-'-.17-1'-----...? [_;.';-.:::.-.-.. ;!:..'-',1e-.)- -4.,-,..-'..----,---:-, --....- -- ,- •..-. . - , ... ... - . CONTRACTOR ----------.4---'44 .....--" - — Residential Mounting System :=ii.P:,',i-:, in Lll,lc*ii-t". ; Residential Mounting System olar Wolf Energy Address:771 Washington St. Auburn,MA 01501 ainaple 31,1,a,,,,-,,id,1,,1 r . I • ,. Phone number:(668)87841396 License*:13440672 101*- < UUe elkSOLAR WOLF- . ' ,,,ENERGY. t. ' * It--'411° 1111010111 . . ,.. .., . , 4 .. ., ., ..,..., , ... 1 I ..1..I.. ,,, ..,,,.... , •Z'. r C.. , , --..... . .. .... .. .- __.-...... RACKING . . DATA SHEET ENGINEEAINC , MO. Drawn by:NAAVenrineerin.lo sunpower.cOM I DATE 08/2012021 A...... 0 , , , , Marcy Cohen 12 St Andrews Way South Yarmouth,MA 02664 Po. yoa PV SYSTEM SUNP WER' SUNP WE R' AS INDICATED D 7.0 MODULES ON ROOF DESIGN CRITERIA POdff#AA6<'�f`V!%['fiQp}i?ER/dtRAy Prior to the commencement of work,the contractor shall verify the existing roof and Solar Module Modules: Module Weight(Ibs) 429 framing conditions.Notify New@engineerinc.io of any Discrepancies prior to 12 #Of Modules 12 starting construction. Attachmen Rafter z x 8 24'o.c. Max Distributed Load:3 PSF Total Modu a Weight(lbs) 514.8 Prior to the commencement of work,the contractor shall inspect framing for any Plywood 8 BuddingFelt damage such as water damage,cracked framing,etc.and notify �bcldng Rack Weight(Ibs) 102.96 New@engineednc.io if any issues are found. 1 Layer of Comp.Shingle. DF62 Total System Weigh(Ibs) 617.76 These Plans are stamped for structural code compliance of the roof framing 2x10 ft Of Standoffs 22 Da9 Max Span Between Standoffs(in) 48 supporting the proposed PV installation reference only.These plans are not Loading Per Standoff Ohs) 28.08 stamped for water leakage.PV modules,racking,and attachment components Total Area(sg.f1) 216 must follow manufacturer guidelines and requirements. Loading(PSF) 2.86 Attachments to be installed in a staggered orientation to:::4 : 0- Sole, y distribut Wolf Enemy Address:771 Washington 8L Aebum,MA 01501 Phone number:(888)8784396 Licensee:B640672 A ATTACHMENT RAIL • ilk SOUR WOLF ----------_____—___ Rafter 2x8 fp24"O.C. `a ENEPGYkc PEGASUS ATTACHMENT DETAILS \ \ \ \ LightSpeed Flashing , \ ROOF ASSEMBLY O \\ \\\ \ 41' -1L11------ '''''\.&\''''.''.4\4:,'\;:'\\\,\‘:,\':',\\ 4 .,: ATTACHMENT SuppodBock EPDMWASHER LAYOUT V.i � O_ GNGINECRINC Drawn by:Neagenaneeano; DATE:08/24/202? o Maw Cohen maglk• 12 St AndreweVv y South Yamwuth,MA 02664 PV SYSTEM AS INDICATED PV 5.0 LABEL I LABEL 2 LABEL 3 LABEL 4 LABEL 5 LABEL 6 CAUTION CAUTION WARNING'. AUTHORIZED SOLAR SOLAR DC CURRENT PRESENT ELECTRIC SHOCK HAZARD. __ F ELECTRIC SHOCK HAZARD, PV SUB-PANEL ONLY PERSONNEL ONLY DURING DAYLIGHT HOURS IF GROUND FAULT IS INDICATED, � "' ,• ""� CO NOT TOUCH THE TERMINALS. NORMALLY GROUNDED TURN RAPID SHUTDOWN TERMINALS ON EOTH THE LINE AND (TO BE LOCATED ON (STICKER TO BE LOCATED ON CONDUCTORS MAY BE SWITCH TO THE LOAD SIDES MAN BE ENERGIZED IN SUB-PANEL ONLY CONDUIT LMTH DC CURRENT UNGROUNDED AND ENERGIZED. "OFF'POSITION TO THE OPEN POSITION. WHEN SUB-PANEL IS EVERY 4'HORIZONTALLY OR SHUT DDOWN PV SYSTEM DEDICATED FOR PV ONLY) 10'VERTICALLY AND 1'FROM EACH SIDE OF A BEND) SHOCK HAZARD IN THE ARRAY LABEL7 LABELS LABEL II LABEL10 LABELII WARNING! PV LOAD CENTER SIZED FOR PV AC DISCONNECT THIS PANEL FED BY SOLAR INVERTER OUTPUT CONNECTION.DO NOT BREAKERS ONLY CR RENDERED UNABLE CONTRACTOR AC PHOTOVOLTAIC POWER SOURCE MULTIPLE SOURCES RELOCATE THIS OVERCURRENT DEVICE TO ACCEPT ANY ADDITIONAL LOADS. RATED AC OUTPUT CURRENT:19,65 A MAX (UTILITY&SOLAR) Solar Wolf Enemy NOMINAL AC OPERATING VOLTAGE:240 Vac (STICKER LOCATED (STICKER LOCATED INSIDE PANEL INSIDE PANEL (STICKER LOCATED AddressA Millington St. NEXT TO SOLAR BREAKER) BELOW PV BREAKER) PhoneON THE PV SUB PANEL) Auburn,MA 01501 DIRECTORY wne number(aea)878-4396 License:B4140672 Permanent directory or plaque providing location of service disconnecting means and photovoltaic system disconnecting means,if not located at the same location.(Plaques shall be metal or plastic,with engraved or machine printed letters,or eleclro-photo plating,in a contrasting color to the plaque.Plaques shall be permanentlyCO j� attached to the equipmenq or in the required location using an approved method that is suitable to withstand the '`-7ESNEY ins environment to which it is exposed.Plaques and signage shall meet legibility,defacemet,exposure and adhesion requirements of Underwriters Laboratories marking and labeling system 969(UL969). INVERTER if applicable ` O SUB pinald MAIN SERVICE // PVS ANEL IaPplicable AC PANEL INTEGRATED 'd appicable DISCONNECT 7 8 PV ARRAY U BOX DC DISCONNECT O 11® O ® 'if applicable O 12 O f 0 3)m10—Q 10 — 07 —I: O 10 MARKINGS,LABELS AND WIRING SIGNS A Purpose:Provide emergency responders with appropriate warring and guidance with rasped to isolating eater electric system. This can facltate identifying energized dectrice tines that connect solar panels to the inverter,as these shade not be as when venting for smoke removal B.Men Service Disconnect. 1.Residential buildings-The marking main be placed within the main service disconnect.The marking shal be placed outride cover if the man disconnectservioedisconnectis operable withthe service panel closed. SYSTEM 2.Commercial holdings-Tha marling she be placed adjacent to the main service disconnect clearly visible tom the location where the levels operat ed 3.Markings:Verbiage,Fame and Type or Material. LABELING DETAIL a.Verbiage:CAUTION:SOLAR ELECTRIC SYSTEM CONNECTED b.Format:White lettering one red background.Minimum 3/8inches letter height Al letters shall be aptaleud.Mal on dmian kart,non bold. c.Material:Reflective,weather redstart material suitable for the environment(use UL-969 as standard for weather rating).Durable adhesive materials meet this requirement. ENGINEERING C.Mertdrrg Requirements Requirements on DC conduit,raceways,enclosures,cable assemblies,DC combiners and junction boxes: dawn by N412021e e.Placement: mdrtab 1.Markings:Verbiage,Format and Type of Material. DATE:08/242021 Maridnps sled be placed every 10feet on al interior and exterior DC conduits,raceways,encbsurea,and cable assemblies, at Ins,above and M below penetrations,all DC combiners and junction boxes b.Verbiage:CAUTION:SOLAR CIRCUIT Note:The format and type of material ahal adhere to V.V-3b,c"of this requirement. Marcy Cohen V Inverters are not required to have caution markings .... 1.Meld d ng is required on as interior and exterior DC conduit raaweys,eosues,a assemblies and assemblieand junction boxes,combiner boxes and disconnects. 12 St Andrews Way 2.The materials used for marling she be reRective,wealher resistantmaterial suitable for the ewiranmert. Scum Yarmouth,Ms,02664 Minimum 3/8'later height;a upper case edema Axial or similar fort Red background with white lettering. _ 3.Marddng shall contain the words:WARNING:PHOTOVOLTAIC POWER SOURCE. PV SYSTEM AS INDICATED 4.Merldng shag be placed adjacent to the main service Asconnect in a location dearly visible horn the location where the disconnect is operated PV 3.0