HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. 72 Lot 9- / Zone of Contribution: In_ OutAcreage 131 '/' '
Commercial: Residential:
Street: / ; 8 C4_-t4`(Li Coker,ib ---
Village: Floor Plan:
Bedrooms:
Owner: Installer: Fit v'f '
Address: Phone:
Phone:
Builder: Engineer: Cleo -Cc ',
►Address:
xr ►rCi+'J r sr✓-tom.
Phone: Phone:
N/A YES NO 1. Required#of copies received
2. Date of soils exam and percolation test not older than 2 years
3. 4-5 ft of naturally occurring pervious material, above water table --- -
4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: d -i
- -
5. Water line 10 ft from septic components Var.: I 6. Benchmark indicated and shown-NGVD if near wetlands C�7. Septic tank minimum 10 ft from foundation, deck Var.:
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: I -€..Z.-
9. Leaching minimum 100 ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11. Tank/leaching minimum 10 ft from property line Var.: e. -
12. System meets all other setback requirements Var.: \`
13. Uses adjustment for maximum high groundwater Var.: `/
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.:
15. System not in top or subsoil (A,B horizons)or 5' removal I
16. Proposed contours are suitable
17. System meets slope requirements-min. 1/8", %"preferred
18. System meets breakout requirements PVC liner: Wall: I i.19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel
21. No garbage disposal
22. System adequately sized for its intended use v
23.Minimum 6"stone or compacted below tank and dbox I /./.
24. Manhole covers within 6"of grade, pump chamber cover to grade
25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes
27. Pump system-2"line,weep hole,check valve, tee in dbox, pump size o••• •
28. Septic tank/pump chamber to be factory waterproofed r�
29. Vent provided if leaching below 3 feet,under driveway/parking
30. Buoyancy calculations for lank/pump chamber G/
31. Engineer to inspect and certify soils: wall: commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature '
33. H-20 loading is subject to vehicular traffic,groundwater
34.Title V Application and permit fee, installer signature
35. Foundation footing min. 2 feet above adjusted ground water for new house
36. Deed Restriction required max. #bedrooms: max. flow:
gpd 1
137. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: _ �L
co.o;
1Y-eA 1 - 3- 3