HomeMy WebLinkAbout142 Route 6A plan 2The following table of abbreviations is provided for the convenience of the contractor. It is not intended
ABBREVIATIONSto serve as a complete list of abbreviations to be found in the contract documents. should the contractor
require any clarification or interpretation hereof, they shall promptly so notify the designer.
A.C.
-ACOUSTICAL CEILING
A.F.F.
-ABOVE FINISH FLOOR
BITUM.
-BITUMINOUS
BLDG.
-BUILDING
C.J.
-CONTROL JOINT
CLG.
-CEILINGS
CLR.
-CLEAR
CMU
-CONCRETE MASONRY UNIT
CONC.
-CONCRETE
CONT.
-CONTINUOUS
CPT.
-CARPET
C.T.
-CERAMIC TILE
DTL.
-DETAIL
DIA.
-DIAMETER
D.W.
-DISHWASHER
DISP.
-DISPOSAL
DN.
-DOWN
D.F.
-DRINKING FOUNTAIN
DWG.
-DRAWING
EA.
-EACH
EJ.
-EXPANSION JOINT
E.W.C.
-ELECTRIC WATER COOLER
ELEV.
-ELEVATION
EQ.
-EQUAL
EQUIP.
-EQUIPMENT
EXP.
-EXPANSION
EXT.
-EXTERIOR
EXIST.
-EXISTING
F.E.C.
-FIRE EXTINGUISHER CABINET
FLR.
-FLOOR
F.D.
-FLOOR DRAIN
GEN.
-GENERAL
GL.
-GLASS
GWB.
-GYPSUM WALLBOARD
H.C.
-HANDICAPPED
HT.
-HEIGHT
H.M.
-HOLLOW METAL
HORZ.
-HORIZONTAL
H.P.L.
-HIGH PRESSURE LAMINATE
MACH.
-MACHINE
MAX.
-MAXIMUM
M.B.
-MARKER BOARD
M.D.O.
-MEDIUM DENSITY OVERLAY
MIN.
-MINIMUM
MFR.
-MANUFACTURER
M.O.
-MASONARY OPENING
MTL.
-METAL
MT.(D)
-MOUNTED)
N.I.C.
-NOT IN CONTRACT
N.T.S.
-NOT TO SCALE
O.C.
-ON CENTER (CENTER TO CENTER)
OPP,
-OPPISITE
O.H.D.
-OVERHEAD DOOR
PCs.
-PIECES
PL.
-PLATE
PLY(WD.) -PLYWOOD
P.S.
-PROJECTOR SCREEN
P.T.
-PRESSURE TREATED
PTD.
-PAINTED
R.
-RADIUS, RISER
R.D.
-ROOF DRAIN
R.L.
-RAIN LEADER
RM.
-ROOM
R.S.
-ROLLER SHADE
S.A.T.
-SUSPENDED ACOUSTICAL TILE
SCHED.
-SCHEDULE
SHT.
-SHEET
SIM.
-SIMILAR
SPEC.
-SPECIFICATION
SQ.
-SQUARE
S.S.
-STAINLESS STEEL
ST.
-STREET
STD.
-STANDARD
STL.
-STEEL
STO. RM.
-STORAGE ROOM
SUSP.
-SUSPENDED
T.
-TREAD
T.B.
-TACKBOARD
TYP.
-TYPICAL
U.O.N.
-UNLESS OTHERWISE NOTED
V.B.
-VAPOR BARRIAR
VERT.
-VERTICAL
W/
-WITH
WD.
-WOOD
BARN ADDITION
for:
ZUCCALA RESIDENCE
777)7
REV! CODE COMPL1-
AP CE -ERA '')O tS OR OMMISSIONIS I �O ��a I IRE! IEVE THE
APPLICAN-1 FROM THE RESPO 1SISILITY OF "AS BUILT"
COMP ., i ;: E.
GENERAL NOTES:
1. G.0 IS RESPONSIBLE FOR ALL LOCATIONS OF POWER, DATA, LIGHT FIXTURES & LIGHTING PLANS, OUTLET LOCATIONS
& HEIGHTS, ETC.
2. G.C. IS RESPONSIBLE FOR ALL STRUCTURAL ELEMENTS THROUGHOUT BUILDING. ALL EXISTING STRUCTURAL
CONDITIONS SUCH AS FOUNDATIONS, SLABS, FOOTINGS, ETC. WIU NEED TO BE INSPECTED AND STRUCTURALLY SOUND
TO ACCOMMODATE NEW LOADS AND STRUCTURE.
3. G.C. MUST DESIGN ALL MEMBERS.
ALL JOIST SIZES SHOWN ARE TAKEN FROM IBC 2015 "FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES"
TABLE R502.3.1(2), PG 127.
THEREFORE CONTRACTOR IS RESPONSIBLE FOR ALL MEMBERS (WHETHER CHANGED OR FOLLOWED
IN PERMIT SET) i.e. SPANS, POST, BEAUS, ETC. AND IS RESPONSIBLE FOR ALL STATE & LOCAL BUILDING CODES.
DRAWING INDEX:
AO.1 COVER SHEET
ARCHITECTURAL
A1.1
FOUND. & FIRST FLOOR PLAN
A1.2
SECOND FLOOR & ROOF PLAN
A1.3
FRAMING PLANS
A2.1
EXTERIOR ELEVATIONS
A3.1
BUILDING SECTION
A3.2
BUILDING SECTION & DETAILS
A6.1
SCHEDULES & WALL TYPES
NOTATION SYMBOLS
A
INTERIOR ELEVATION TAG D B
C
DOOR TAG DOOR #
WALL TAG WALL
TYPE
WINDOW TAG WIN.
TYPE
Q
Q Q D
Q 0
Q o��
z N
Iz z_ Q
CO
CV
d'
U
a
Scale
Sheet No.
m
❑
N
U)
AS NOTED
N
O
N