HomeMy WebLinkAbout142 Route 6A plan 8RIDGE VENT (TYP.) to 0 CUT RAFTER TAIL @ EA. RAFTER TO ATTACH TRIM TO WALL TYPE 'B' PROVIDE JOIST HANGERS @ EA. FLOOR JOIST AT BEAM WALL TYPE 'B' a ra C n Q 3/4" PLYWOOD SUBSTRATE 2x10 WD. JOIST @ 12" O.C. ROOF CONSTRUCTION: (TOP TO BOTTOM) ASPHALT SHINGLE FINISH w/ GRACE ICE AND WATER SHIELD OR EQUAL MIN. 6'-0" FROM ALL EAVES & GABLE ENDS (SEE ROOF PLAN). ENTIRE REST OF SHEATHING TO HAVE ROOF MOISTURE BARRIER (TYP.), 3/4" PLYWOOD SHEATHING OR ZIP SYSTEM SHEATHING. 2x10 RAFTERS @ 16" O.C. GWB FINISH ON Ix3 STRAPPING @ 24" O.C. (TYP.) 2x8 WD. CEILING COLLAR TIE @ EA. RAFTER (TYP.) NOTE: GABLEWALLS ON BOTH ENDS. PROVIDE BALLOON FRAMING (TYP.) LOAD BEARING WALL TO SUPPORT BEAM (SEE FRAMING PLAN) 2x8 COLLAR TIE @ EA. RAFTER (TYP.) — m_ NOTE: FOR ALL STAIRS AND LANDINGS, PROVIDE HANDRAIL SEE NOTES ON 2 / A3.2 (MOUNTED TO WALL OR STRINGERS) 36" A.F.F. (BOTH SIDES). 2x12 WD. LEDGER FOR STAIR STRINGER BUILT-UP BEAM 2x10 @ STAIR OPENING LALLY COLUMN TO SUPPORT FLOOR ABOVE MICHELE ` `-, `7 CUDILO N0.34773 STRUCTURAL UCT. ONLY BLOCKING LAP ROOF FINISH OVER BLOCKING)'B'-. FLASHING (TYP.) ALUM. RAKE FLASHING @ GABLE ENDS CUT RAFTER TAIL WALL TY@ EA. RAFTER TO ATTACH TRIM TO VENTED SOFFIT E ch o w x m � CS16 x 4' @ EA. STUD �— PROVIDE LSO Z SIMPSON STRONG TIE STRINGER CONNECTOR (EA. STRINGER) SECOND FLOOR' ---•-----•——•—•—•—.—•—•—-----•----10'0" v ce pq , a ADD BLOCKING TO RIM BOARD WHERE FLOOR IS 10" 3'I OPENED (TYP.) TREAD'I I LANDING 4-1 x P o x o w 0 0 0 LALLY COLUMN TO SUPPORT — — — — o '� a a ED FLOOR ABOVE — — — — O o S — p W E 0 aof & o W 134 E 0 0 ' 4x4 P.T. POST @ CORNER w w OF STAIR LANDING — -� —---•—.-----—•--------- •—•— — — — — — •----- — — —•—•— -- ------- 6" CONC. SLAB (TYP.) VAPOR BARRIER I a —WALL _ IIII I I I I I I I I _ IIII Iill .III — -: FOOTING DIMENSIONS SHOWN AT MINIMUM = _ -PROVIDE FOUNDATION - — FOOTING REQUIREMENTS. G.C. MUST =KEYWAY AT FOOTING 1 DETERMINE ON SITE ADEQUATE SIZING FOR (YP. T 4FOOTING PRIOR TO INSTALLATION (TYP.) �i - Ff�-i rf- -it - >i III) IIII =IIII BUILDING SECTION 2 Scale: 1/2" = 1'-0" IN U N r PROVIDE BLOCKING WHEN STUDS ARE GREATER THAN 8'-0" (TYP.) N 0 N N O LV O CM 0) 0 PROVIDE (2) #4 REINFORCEMENT 2" MIN CLEAR CO XX_ T.O. FOUND. -o = Lu — — — - FL: SLAB O Q j 0 0 A A' ' A < z _ � ��— � BDRY LALLY COLIIMN o = 0 i U � — INTO FOOTING (TYP.) = 0 ::) Q �- »�T C I I z W ry z < cn o 00 z I II I I I IIII III _ I z _ � o - J i PROVIDE FOUNDATION � - CV KEYWAY AT FOOTING (TYP.) III T 0 FOOTING m FOOTING DIMENSIONS SHOWN AT MINIMUM FOOTING OF REQUIREMENTS. G.C. MUST DETERMINE ON SITE ADEQUATE Scale _SIZING FOR FOOTING PRIOR TO INSTALLATION (TYP.) _ AS NOTED IIII IIII IIII IIII IIII —IIII - IIII IIII IIII IIII IIII IIII IIII IIII IIII IIII IIII Sheet No. 2 STAIR SECTION A3*2 A3.2 Scale: 1/2" = 1'-0"