Loading...
HomeMy WebLinkAboutBLD-23-003436 ONE & TWO FAMILY ONLY- BUILDING PERMIT ,' J4 E C i `'"1 Town of Yarmouth Building Department 1146 Route 28,South Yarmouth,MA 02664-4492 �, ,% 2 ,1 ^� . , 508-398-2231 ext. 1261 Fax 508-398-0836 �i '� =J L,;(2 Massachusetts State Building Code,780 CMR / . Building Permit Application To Construct, Repair, Renovate Or Demolish BEM,:, , a One-or Two-Family Dwelling ---- This Section For Official Use Only Building Permit Number: J j,n �7j --b6 3(.4 30 Date Applied: l Build c. (Print Name) Signature Date SECTION 1:SITE INFORMATION L1 Property Address: j 1.2 Assessors Map&Parcel Numbers 25 Monroe Ln 67 18 1.1 a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards I Rear Yard Required I Provided Required Provided Required i, Provided I 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone: Outside Flood Zone? — Municipal 0 On site disposal system ❑ Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Schutte Fatima Yarmouth MA 02673 Name(Print) City,State,ZIP 25 Monroe Ln (774)368-5071 fatima.pezenti@hotmail.com No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction 0 Existing Building a' Owner-Occupied V Repairs(s) 0 Alteration(s)VI Addition 0 r Demolition 0 1 Accessory Bldg. 0 Number of Units i Other Specify: Roof Mounted Solar Brief Description of Proposed Work'`: Installation of a interconnected, roof mounted, photovoltaic solar energy system consisting of al.f solar panels producingq 7 Kw DC. NO ESS SECTION 4:ESTIMATED CONSTRUCTION COSTS. Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building S 5476 1. Building Permit Fee:S_ Indicate how fee is determined: 2.Electrical S I 0 Standard City/Town Application Fee T12776 ❑Total Project Cost3(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 2��,I 4.Mechanical (HVAC) $ List: CA aZtR J1f) _ 5.Mechanical (Fire I Suppression) $ Total All Fees:$ Check No. Check Amount: Cash Amount: 6.Total Project Cost: $ 18252 0 Paid in Full 0 Outstanding Balance Due: r SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-040622 08/01/2023 Stephen Kelly License Number Expiration Date Name of CSL Holder U List CSL Type(see below) 16 Parkway Rd. No.and Street Type Description Stoneham MA, 02180 U Unrestricted(Buildings up to 35,000 cu.ft,) R Restricted l&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 978 793-7881 eastmapermits@sunrun.com I Insulation Telephone Email address D I Demolition 5.2 Registered Home Improvement Contractor(HIC) HIC - 180120 10/13/2024 Sunrun Installation Services Inc./ Stephen Kelly HIC Registration Number Expiration Data HIC Company Name or HIC Registrant Name 21 Worlds Fair Dr. eastmapermitsnsunrun.com No.and Street 978 793-7881 Email address Somerset, NJ, 08873 City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(N'I.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes No 0 . SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Sunrun Installation Services Inc./Stephen Kelly to act on my behalf,in all matters relative to work authorized by this building permit application. Schutte Fatima See Attached Contract 12/16/2022 Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Stephen Kelly a 12/16/2022 Print Owner's or Authorized Agen's Nam icctronic Signature) Date NO +S: I. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.aov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" • __��....14 SUNRINC-02 LWANG2 ACORO- DATE(MM/DD/YYYY) �� CERTIFICATE OF LIABILITY INSURANCE 8/31/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER License#0C36861 CONTACT NAME: Walter Tanner Alliant Insurance Services,Inc. PHONE FAX 560 Mission St 6th Fl IA/C,No,Ext►: (AIC,No): San Francisco,CA 94105 ealAa SS:Walter.Tanner@alliant.com ADDRE INSURERS)AFFORDING COVERAGE NAIC II INSURER A:Evanston Insurance Company 35378 INSURED INSURER 8:James River Insurance Company 12203 Sunrun Installation Services,Inc INSURER C:American Zurich Insurance Company 40142 775 Fiero Lane,Suite 200 Ph#805-540-7643 INSURER D: San Luis Obispo,CA 93401 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSRT— ADDLISUBRI I POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD, POLICY NUMBER (MM/DD/YYYY) (MMIDD/YYYY) LIMITS A ' X COMMERCIAL GENERAL LIABILITY I EACH OCCURRENCE $ 2,000,000 CLAIMS-MADE X OCCUR MKLV5ENV103749 10/1/2022 10/1/2023 DAMAGETORENTED 1,000,000 PREMISES(Ea occurrence) $ MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY S 2,000,000 GEM.AGGREGATE LIMIT APPLIES PER: 'GENERAL AGGREGATE S 2,000,000 X POLICY X I JECT LOC _PRODUCTS-COMP/OP AGG $ 2,000,000 X OTHER:Retention: $100,000 Per Project Agg $ 5,000,000 AUTOMOBILE LIABILITY (EaMacc ideertt) LIMIT $ — ANY AUTO _ BODILY INJURY(Per person) S• OWNED 7 SCHEDULED AUTOS ONLY _I AUTOS BODILY INJURY(Per accident) $ HIRED --.�I NON-OWNED PROPE )AMAGE $ . AUTOS ONLY __ AUTOS ONLY (PPeerr 1I --- -� $ B UMBRELLA LIAB X OCCUR I EACH OCCURRENCE $ 4,000,000 X EXCESSUAB CLAIMS-MADE 001072261 10/1/2021 10/1/2022 AGGREGATE • $ 4,000,000 DED RETENTION$ $ C DKERSCOMPENSATION PER OTH- AN EMPLOYERS'LIABILITY XSTATUTE ER YIN WC6142B7601 10/1/2022 10/1/2023 1,000,000 ANY PROPRIETOR/PARTNER/EXECUTIVE N N/A E.L.EACH ACCIDENT S (Mancha ry to R�EXCLUDED? 1,000,000 (Mandatory to NH) 1 E.L.DISEASE-EA EMPLOYEE S If yes.describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L DISEASE-POLICY LIMIT I$ 1 1 i DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached It more space is required) Workers'Compensation Policy WC614287601 Deductible:$1,000,000. Re:Permitting within jurisdiction. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of Yarmouth THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. 1146 Route 28 South Yarmouth,MA 02664-4492 AUTHORIZED REPRESENTATIVE ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD r The Commonwealth of Massachusetts Department of Industrial Accidents _ = Office of Investigations �,L t ==i_rI— i;l Lafayette City Center ='=• f 2 Avenue de Lafayette, Boston,MA 02111-1750 w www.mass.gov/dia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Sunrun Installation Services /Stephen Kelly Address: 225 Bush St STE 1400 City/State/Zip: San Francisco CA 94104 _ Phone#: 978 793-7881 Are you an employer? Check the appropriate box: Type of project(required): 1.® I am a employer with 50 4. 0 I am a general contractor and I employees(full and/or part-time).* have hired the sub-contractors 6. El New construction 2.❑ I am a sAliste on theattached sh et. 7. El Remodeling id �l�ri t$I nected, roof n t�r�eElaglzt, yolltaic so areenerg i syste nsistingg of 24 solar panels proddci ship and have no employees 8. 11 Demolition workingfor me in anycapacity. employees and have workers' P h' 9. ❑ Building addition [No workers' comp. insurance comp. insurance.* . required.] 5. 0 We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.]+ c. 152,§1(4),and we have no employees. [No workers' 13.1EI Other Roof Mounted Solar comp. insurance required.] *My applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: American Zurich Insurance Company Policy#or Self-ins. Lic.#:WC614287601 Expiration Date: 10/0 1/2023 Job Site Address: 25 Monroe Ln City/State/Zip: Yarmouth MA 02673 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of peijurr correct. that the information provided above is true and Signature: Gs2e5 Rile: 12/16/2022 Phone#: 978-793-7881 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(check one): 10 Board of Health 20 Building Department 30City/Town Clerk 4.0 Electrical Inspector 50Plumbing Inspector 6.0Other Contact Person: Phone#: Commonweattn or Massachusetts Cons which contain Dwtsion of Professional Licensure Uotestricted •Buildings of any use group Board of Butldint ions and Standards less than 36,000 cubic feet)!01 cubic meters)of enl:fossd tt A'Su . p4rnsor CS O40622 65ires:08/0112023 STEPHEN A ELLY tt PARKWAY'ROAD4 STONEHAM 4 02111 J' ,l f.irJ/S1"131�` ,,� cut Failure to possess a current edition of the Massachusetts usetts pl s CM1110ifNi011t1f sefsl JG nreimt, State Building Code is cause for revocation of this license. For Information about this license Cal(017)727-3200 or visit wwnrnass.govidp1 ! THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs and Business Regulation 1000 Washingida gtreept-Suite 710 Boston,Massactlugetts 02118 Home Improvement ODntractor Registration q _ 'ype Supplement Card SUNRUN INSTALLATION SERVICES INC. •Y Registration 180120 21 WORLDS FAIR DR ,r• FcpiraLon t011 312 0 24 SOMERSET.NJ 08873 Yy ,P Update Address and Return Card. THE COMMONWEALTH OF MASSACHUSETTS ORlce of Consume Allow 8 Business Regulation Ragatnlron wad for witriduai ow only before the HOME iMPROVEIENT CONTRACTOR eepinmon dale.IIun found Mont to: he:TT BuiTp menu Card Office of Cons Anal AIIW.and Buameas Regulation ateinsienq t1a1WI= 1000 Washington Street-8ufb 710 14OUO'; 1i IOrmrdo 4 BMbn.MA 0211E SUNKEN INSTALLATION BINiVICSe 1NC. ,. STEPREN KELLY ,t 225 BUSH STREET V,,,.i ,. (,a• SUITE 1400 SAN FRANChSCO,CA 94104 Urdersecrete y va/d wtthounature Stephen A Kelly 695 Myles Standish Blvd Taunton MA 02780 TEL:978-793-7881 Email: eastmapermits@sunrun.com . By signing below, you acknowledge that you have reviewed and received a complete copy of the Agreement without any blanks. Such Agreement shall be the complete understanding between the Parties. SUNRUN I T LATIQN SERVICES INC. rSignatur : .. a..,„. S 90F56FD25D954C9_. Print Name: carlos solano Date: 11/30/2022 Title: Project Operationc Federal Employer Identification Number: 26-2841711 IF YOU CHOOSE TO PAY BY CHECK, MAKE CHECKS OUT TO SUNRUN INC. NEVER MAKE A CHECK OUT TO A SALES REPRESENTATIVE. OUR SALES REPRESENTATIVES ARE NOT AUTHORIZED TO RECEIVE CHECKS IN THEIR OWN NAMES. YOU MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF THE TENTH EFFECTIVE DATE. PLEASE REVIEW THE ATTACHED NOTICES OF CANCELLATION FOR AN EXPLANATION OF THIS RIGHT. Customer ,Pr' nefcount Holder Secondary Account Holder (Optional) `—BDW We Schutte Fatima Signature 11/30/2022 Date Print Name Email Address*: fati ma.pezenti @hotmai 1 .com Mailing Address: 25 Monroe Ln Yarmouth, MA 02673 Phone: (774) 368-5071 *Email addresses will be used by Sunrun for official correspondence. such as sending monthly bills or other invoices. Sales Consultant By signing below/acknowledge that/am Sunrun accredited, that I presented this agreement according to occlotfflataCode of Conductt, and that/obtained the homeowner's signature on this agreement. EP oiogo Levi ske Print Name 1263079916 Sunrun ID number Sunrun Installation Services Inc. 1225 Bush Street. Suite 1400, San Francisco. CA 94104 i 888.GO.SOLAR 1 HIC §TOWN OF YARMOUTH 1146 Route 28, South Yarmouth, MA 02664 508-398-2231 ext. 1261 Fax 508-398-0836 Office of the Building Commissioner BUILDING DEPARTMENT DEMOLITION DEBRIS DISPOSAL AFFIDAVIT Pursuant to M.G.L. Ch. 40, §54 and 780 CMR- Section 105.3.1. #4. I hereby certify that the debris resulting from the proposed work/demolition to be conducted at 25 Monroe Ln Yarmouth Ma 02673 Work Address Is to be disposed of oat the following location: 695 Myles Standish Blvd. Taunton, MA 02780 Said disposal site shall be a licensed solid waste facility as defined by M.G.L. Ch. 111, §150A. a 12/16/2022 Signa of Applicati Date Permit No. • =- EV projects@evengineersnet.com 276-220-0064 Immw ENGINEERS http://www.evengineersnet.com 12/15/2022 RE:Structural Certification for Installation of Residential Solar SCHUTTE FATIMA:25 MONROE LN,YARMOUTH,MA,02673 Attn:To Whom It May Concern This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report,the roof is made of Composite shingle roofing over roof plywood supported by 2X6 Rafters at 24 inches.The slope of the roof was approximated to be 27 and 28 degrees. After review of the field observation data and based on our structural capacity calculation,the existing roof framing has been determined to be adequate to support the imposed loads without structural upgrades. Contractor shall verify that existing framing is consistent with the described above before install.Should they find any discrepancies,a written approval from SEOR is mandatory before proceeding with install.Capacity calculations were done in accordance with applicable building codes. Design Criteria Code 2015 IRC(ASCE 7-10)-CMR 780 9th Ed Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 140 mph PV Dead Load DPV 3 psf Exposure C Roof Live Load Lr 20 psf Ground Snow S 30 psf If you have any questions on the above, please do not hesitate to call. STRUCT . ONL `1T'" y�Sincerely, EA Ssgc :$ .? VINCENT -tr Vincent Mwumvaneza,P.E. o MWUMVANEZA EV Engineering,LLC N'CIVIL 2 A / proiects@evengineersnet.com .//.- E��.9 http://www.evengineersnet.com • 0NALE c' Signed 12/15/2022 1/1 =- EV projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.com Structural Letter for PV Installation 12/15/2022 Job Address: 25 MONROE LN YARMOUTH,MA,02673 Job Name: SCHUTTE FATIMA Job Number: 121522 SF Scope of Work This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing.All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Table of Content Sheet 1 Cover 2 Attachment checks 3 Snow and Roof Framing Check 4 Seismic Check and Scope of work Engineering Calculations Summary Code 261511iR 'J /-1O MR 780$th Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 30 psf Wind Load (component and Cladding) V mph Exposure C References NDS for Wood Construction STRUCT C ONL SH Of MAssicti 4 VINCENT oP Sincerely, 0 MWUMVANEZA CIVIL Vincent Mwumvaneza,P.E. A Ne i o EV Engineering, LLC �I''�0N0.tc, Nc,���� Signed 12/15/2022 proiects@evengineersnet.com http://www.evengineersnet.com 1/1 • =T EV projects@evengineersnet.com 276-220-0064 miiim ENGINEERS http://www.evengineersnet.com Wind Load Cont. Risk Category= II ASCE 7-10 Table 1.5-1 Wind Speed(3s gust),V= 140 mph ASCE 7-10 Figure 26.5-1A Roughness= C ASCE 7-10 Sec 26.7.2 Exposure= t ASCE 7-10 Sec 26.7.3 Topographic Factor, KZT= 1.00 ASCE 7-10 Sec 26.8.2 Pitch= 274 Degrees Adjustment Factor,it= 1.21 ASCE 7-10 Figure 30.5-1 a= 3.60 ft ASCE 7-10 Figure 30.5-1 Where a:10%of least horizontal dimension or 0.4h,whichever is smaller,but not less than 4%of least horizontal dimension or 3ft(0.9m) Uplift(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= -29.3 -41.3 -65.1 Figure 30.5-1 Pnet=0.6 x A x KZT x Pnet30)= 21.29 29.99 47.28 Equation 30.5-1 Downpressure(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= 15.7 15.7 15.7 Figure 30.5-1 Pnet=0.6 x A x KZT x Pnet30)= 11.41 11.41 11.41 Equation 30.5-1 Rafter Attachments:0.6D+0.6W(CD=1.6) Connection Check Attachement max.spacing= ft 205 lbs/in Lag Screw Penetration 2.5 in Allowable Capacity= 512.5 0.6D+0.6W Dpv+0.6W Zone Trib Width Area(ft) Uplift(lbs) Down(Ibs) 1 6 12.9 251.4 185.9 2 6 12.9 363.6 185.9 3 3 6.5 293.3 92.9 Max= 363.6 < 512.5 CONNECTION IS OK 1. Pv seismic dead weight is negligible to result in significant seismic uplift,therefore the wind uplift governs 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. 1/1 =' EV projects@evengineersnet.com 276-220-0064 mom ENGINEERS http://www.evengineersnet.com Vertical Load Resisting System Design Roof Framing Pg= 30 psf ASCE 7-10,Section 7.2 pf= 21 psf Ce= 0.9 ASCE 7-10,Table 7-2 Pfmin.= 25.0 psf Ct= 1.1 ASCE 7-10,Table 7-3 p5= 25 psf 35.8 plf IS= 1.0 ASCE 7-10,Table 1.5-1 CS 0.717 Max Length,L= 10.17 ft Tributary Width,WT= 24 in Dr= 10 psf 20 plf PvDL= 3 psf 6 plf Load Case:DL+0.6W Pnet+PP cos(6)+PDL= 48.8 plf Max Moment, M = 445 lb-ft Conservatively Pv max Shear 185.9 lbs Max Shear,V„=wL/2+Pv Point Load= 318 lbs Load Case:DL+0.75(0.6W+5)) 0.75(Pnet+Ps)+PPVcos(0)+PDL= 69 plf Mdown= 633 lb-ft Mallowable=Sx x Fb'(wind)= 1319 lb-ft > 633 lb-ft OK Load Case:DL+S Ps+PPVcos(8)+PDL= 61 plf Mdown= 558 lb-ft Mallowable=Sx x Fb'(wind)= 948 lb-ft > 558 lb-ft OK Max Shear,V„=wL/2+Pv Point Load= 353 lbs Member Capacity SPF#1/#2 2X6 Design Value CL CF C, Cr Adjusted Value Fb= 875 psi 1.0 1.3 1.0 1.15 1308 psi Fx= 135 psi N/A N/A 1.0 N/A 135 psi E= 1400000 psi N/A N/A 1.0 N/A 1400000 psi Depth,d= 5.5 in Width, b= 1.5 in Cross-Sectonal Area,A= 8.25 in2 Moment of Inertia,Ixx= 20.7969 in° Section Modulus, Sxx= 7.5625 in3 Allowable Moment, Mail= Fb'Sxx= 824.4 lb-ft DCR=M /Maii= 0.56 < 1 Allowable Shear,Vail=2/3F„'A= 742.5 lb DCR=V /Vaii= 0.24 < 1 1/1 =- EV projects@evengineersnet.com 276-220-0064 wom ENGINEERS http://www.evengineersnet.com Siesmic Loads Check Roof Dead Load 10 psf %or Roof with Pv 25% Dpv and Racking 3 psf Averarage Total Dead Load 10.7 psf Increase in Dead Load 3.0% OK The increase in seismic Dead weight as a result of the solar system is less than 10%of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on information in pictures and a drawing set titled PV plans-SCHUTTE FATIMA.The analysis was according to applicable building codes, professional engineering and design experience,opinions and judgments.The calculations produced for this structure's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. 1/1 r . SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION M •SYSTEM SIZE:9360W DC.7600W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), PV-1 0 COVER SHEET SERVICE ENTRANCE •MODULES.(24)TRINA SOLAR.TSM-390DE09C.07 MUNICIPAL CODE.AND ALL MANUFACTURERS LISTINGS AND INSTALLATION •INVERTERS:(1)SOLAREDGE TECHNOLOGIES. INSTRUCTIONS. PV-2.0 SITE PLAN SE7600H-USSN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. MP MAIN PANEL •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP. PV-3.0 LAYOUT SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020, PV-4.0 ELECTRICAL •NEW 100A MAIN BREAKER DISCONNECT WITH 100A MAIN O. SUB-PANEL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-5.0 SIGNAGE ENCLOSURE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703, 0 SUNRUN METER •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM DEDICATED PV METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). 0 AC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). 0 DC DISCONNECT(S) •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. •13.35 AMPS MODULE SHORT CIRCUIT CURRENT, CB IQ COMBINER BOX •20.85 AMPS DERATED SHORT CIRCUIT CURRENT]690.8(A)&690.8(B)]. •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). ABBREVIATIONS r-1 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE A AMPERE L J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ALTERNATING CURRENT S u n r u n AFC ARC FAULT CIRCUIT INTERUPTER CHIMNEY KM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT / ATTIC VENT #180120 MI EXISTING FLUSH ATTIC VENT VICINITY MAP w MYLES STAND.Kw,TAUNTON.NA moon I ESS ENERGY STORAGE SYSTEM PVC PIPE VENT PHONE° EXT EXTERIOR METAL PIPE VENT CUSTOMER RESIDENCE: INT INTERIOR ,4 T-VENT SCHUTTE FATIMA MOP MAIN SERVICE PANEL /,-A MA,25 M0267ONR3OE LN,YARMOUTH. IN) NEW SATELLITE DISH YarmaJlh NTE NOT TO SCALE TEL.(774)388-5077 OC ON CENTER FIRE SETBACKS pile*+"` NOW of;he NR;xI APN:YARM-000067-000018 PRE.FAS PREXABRICATED -r.... .. IUI� PROJECT NUMBER: • PSF POUNDS PER SQUARE FOOT I HARDSCAPE 25223R•O25FATI w PHOTOVOLTAIC -� •W st Yarmouth,nroe ROD RAPID SHUTDOWN DEVICE PL.— PROPERTY LINE West C MA DESIGNER: (415)580-6920ez3 1L 11UNSFORMERlE55 1---SOLAR MODULES ,,, ARuo.:TH NITESH RANA SCALE.NTS SHEET TYP TYPICAL .11.1111.1 ` g _. Dl KN 5 <:R V VOLTS Is °q SST ; , �.. REV NAME DATE COMMENTS COVER SHEET YARMOUTH, w Huns MEI= _• REV:Al 12/14/2022 LAN LANDSCAPE SNR MOUNT _ PAGE PV-1.0 POR PORTRAIT SNR MOUNT&SKIRT .: TwRyra wmon_I.08T '� m z z g D r m N 9 b ® R El m N ?li E z Ie O m R 6 N R N. R /-'• .i.... *4 • 4111It #4 4. ° ' OyRO� • ° '''' ° -• 441\14%, IT, m z m \ m _ °• ° ? m R , m a m O f -, .- y D N b I Nd n ZI =( m ; m c WI W W ;0 W -en- al N •A cri y D m S z m N 31 Z m ;; C 0 5 m ,N m y m m 5 x'm (� Do pC- " N v+ = z on � mz4; f cn my p q z 1 W O m� 4 Z D C m D M R < m > �mIV -a FR bb0 rz-Ipm 3 p E DDIIi xi z 9 in N Z $ o p m o z C N x 9 W ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF RL UNIVERSAL.SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 2-Story 2X4 PRE-FABRICATED TRUSSES 10'-2" 24" COMP,SEE DETAIL SNR-DC-00436 6'-0" 2'-4" 4'-Cr 2'-0" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREW AR-02 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 10'-2" 24" RL UNIVERSAL,SPEEDSEAL TRACK ON 4'-Cr 2'-0" STAGGERED 5/16".2.5"MIN.EMBEDMENT COMP,SEE DETAIL SNR-DC-00436 D1-AR-01-SCALE:3/16"=1•-0" AZIM:129' 29' PITCH:28° MM. = = = STRUC ONL VINCENT¢y ��� iD,_i t,. �� VINCENT �� çWUTMmAito V ) ANEZA - - - - - - CIVIL ��� N.. Signed 12/15/2022 ' D2-AR-02-SCALE:1/4"•1•-0" AZIM:129" s u n r u n PITCH 27" 8"ti 17'-5" 8 { INSTALLERS SHALL NOTIFY ENGINEER OF 0 C 0 - ANY POTENTIAL STRUCTURAL ISSUES #180120 OBSERVED PRIOR TO PROCEEDING WI INSTALLATION. 096 rnae 61°n0199 nw.'AMOR w,027.7131 CHOW 0 •IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" rr.xa BOUNDARY REGION OF ANY ROOF PLANE • EDGES(EXCEPT VALLEYS),THEN CUSTOMER RESIDENCE: ❑ ❑ 0 ATTACHMENTS NEED TO BE ADDED AND SCHUTTE FATIMA 1 OVERHANG REDUCED WITHIN THE 12" 25 MONROE LN,YARMOUTH, id 10'11„BOUNDARY REGION ONLY AS FOLLOWS: MA,02673 4� "ALLOWABLE ATTACHMENT SPACING • INDICATED ON PLANS TO BE REDUCED BY TEL.(774)368.5071 • 50%. APN.YARM-000067-000018 '•ALLOWABLE OVERHANG INDICATED ON PROJECT NUMBER: 1 PLANS TO BE 1/5TH OF ALLOWABLE 223R-025FATI •- --8'TYP--- f ATTACHMENT SPACING INDICATED ON PLANS. • • ( DESIGNER: 1415)580-6920 ex3 • • I O 0 0 - _ _ NITESH RANA 1'10" SHEET LAYOUT REV:Al 12/142022 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 r"mpieb_."nv"_.0.07 SHEET INDEX LEGEND SCOPE OF WORK ' GENERAL NOTES PAGE# DESCRIPTION 21 1 •SYSTEM SIZE,9360W DC.7600W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), PV-1 0 COVER SHEET SERVICE ENTRANCE •MODULES:(24)TRINA SOLAR.TSM-390DE09C.07 MUNICIPAL CODE,AND ALL MANUFACTURERS LISTINGS AND INSTALLATION •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. PV-2.0 SITE PLAN SE7600H-USSN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. MP MAIN PANEL •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP. PV-3.0 LAYOUT SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV-4 0 ELECTRICAL •NEW 100A MAIN BREAKER DISCONNECT WITH 100A MAIN SP SUB-PANEL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-5.0 SIGNAGE ENCLOSURE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM DEDICATED PV METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). O AC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). O DC DISCONNECT(S) •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. •13.35 AMPS MODULE SHORT CIRCUIT CURRENT. CB IQ COMBINER BOX •20.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(13)(2). ABBREVIATIONS E—1 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE A AMPERE L__I SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPIER CHIMNEY $(J I U fl ADA AZIMUTH COMP COMPOSITION DC DIRECT CURRENT ATTIC VENT #180120 — (El EXISTING [J FLUSH ATTIC VENT VICINITY MAP _ M TANRI SIND TAUNTON,MA,0270041N ESS ENERGY STORAGE SYSTEM O PVC PIPE VENT FFAA0 EXT EXTERIOR 0 METAL PIPE VENT CUSTOMER RESIDENCE: INT INTERIOR El T-VENT "�- SCHUTTE FATIMA LISP MAIN SERVICE PANEL "�`- i'` `tiA, 25 MONROE LN,YARMOUTH, NI NEW SATELLITE DISH a Yie rnoott; MA,02873 NTS NOT TO SCALE .T•. . 'c* TEL(774)388-507t DC PREFABRICATED CENTER RATEO FIRE SETBACKS - -,.�� Nmy of the Republic r''N' APNPROJECT YARM NUMBER: PRE-FAS PSF POUNDS PER SQUARE FOOT :] HARDSCAPE 223R-025FATI yS�" L. PV PHOTOVOLTAIC I e�• (415)580-6920 ex3 RSD RAPID SPUTUM'S DEVICE PL— PROPERTY LINE '«'+r't 110U1.1. DESIGNER: TL TRANSFORM RLESS - SOLAR MODULES NITESH RANA SCALE:NTS �WM v'K; VT SHEET VOLTS REV NAME DATE COMMENTS COVER SHEET W WATTS =In= •-- REV:Al 12/14/2022 `"." LANDSCAPE SNR MOUNT - PAGE PV-1.0 FOR PORTRAIT SNR MOUNT&SKIRT Tsnplee_rnm_4.0.31 120/240 VAC SINGLE PHASE • SERVICE M O METER#. EVERSOURCE 2284017 UTILITY GRID NEW 100A MAIN I BREAKER DISCONNECT r WITH 100A MAIN NOTE.TOTAL PV BACKFEED=40A \ ENCLOSURE USED FOR INTERCONNECTION 1 CALCULATIONS LOAD SIDE TAP ., (N)LOCKABLE /1 BLADE TYPE (N)MA SMART EXISTING 100A MAIN BREAKER FUSED AC UTILITY SOLAREDGE TECHNOLOGIES. f DISCONNECT METERUE SE7600H-USSN 7800 WATT INVERTER JUNCTION BOX PV MODULES �, © 0 0 © OR EOUNALENT 1 (24)TRINA .TSM-390DE09C.07 EXISTING 125A // (24)MODULES MAIN PANEL ; e,o, ; O ; .-�; ; MI ; A / OPTIMIZERS WIRED IN FACILITY 40A FUSES ...M♦ (1)SERIES OF(12)OPTIMIZERS LOADS SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT D222NRB 100A CONTINUOUS WITH AFCI.RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R.60A UTILITY SIDE OF CIRCUIT COMPLIANT S440 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM/ CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPERI 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 Still r u n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 wsw0sounw aw.TAUNTON ru o_-.Olt 0 CUSTOMER RESIDENCE: SCHUTTE FATIMA 25 MONROE LN,YARMOUTH, 4 MA,02673 MODULE CHARACTERISTICS S440 OPTIMIZER CHARACTERISTICS: TEL.(774)368-5071 .. TRINA SOLAR:TSM-390DE09C.07: 390 W MIN INPUT VOLTAGE 8 VDC APN YARM-000067-000018 OPEN CIRCUIT VOLTAGE. 40.8 V MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: MAX POWER VOLTAGE 33.8 V 4 MAX INPUT ISC: 14.5 ADC 223R-025FATI SHORT CIRCUIT CURRENT: 13.35 A MAX OUTPUT CURRENT. 15 ADC DESIGNER: 1415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 NITESH RANA SYSTEM SIZE: 9360 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE 12 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:Al 12/14/2022 SYSTEM OPERATING CURRENT: 23.4 A SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0 TrrpYY v 1441 NOTES AND SPECIFICATIONS , WARNING INVERTER 7 •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 800.OR PHOTOVOLTAIC DC DISCONNECT IF REQUESTED BY THE LOCALAHJ. ELECTRICAL SHOCK HAZARD •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS.COLORS AND SYMBOLS t.IAXIMUM SYSTEM VOLTAGE: 480 VDC •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING TERMINALS ON UNE AND LOAD METHOD AND SHALL NOT BE HAND WRITTEN. SIDES MAY BE ENERGIZED IN LABEL LOCATION: •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT THE OPEN POSITION INVERTER(S),DC DISCONNECT(S) INVOLVED. PER CODE(S).NEC 2020.880 53 •SIGNS AND LABELS SHALL COMPLY WITH ANSI 2535.4-2011,PRODUCT SAFETY SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED LABEL LOCATION: INVERTERS,ON,AC DISCONNECT(S). DO NOT COVER EXISTING MANUFACTURER LABELS. AC COMBINER PANEL(IF APPLICABLE) PER CODES'NEC 2020 880.13(8) WARNING: PHOTOVOLTAIC WARNIN POWER SOURCE LABEL LOCATION ' DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, _ ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020,BOO 31(D)(2),IFC 2012: SYSTEM 605.71.1. CAUTION : LABEL LOCATION UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S)NEC 2020 705 72(C) RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER /NWARNING POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM DO NOT RELOCATE THIS ' , OVERCURRENT DEVICE LABEL LOCATION INSTALLED WITHIN 3'OF 2SHUT DOWN $u n I U LABEL LOCATION: E N: SWITCH PER CODS-NEC 2020 880.56(C)121,IFC ADJACENT TO PV BREAKER AND ESS 2012 805 11 1 IFC 2018-1204 5 3 OCPD(IF APPLICABLE). PER CODE(S):NEC 2020: y__ 705.1203)(3)(2) _ -- WARNING SOLAR PV SYSTEM EQUIPPED -le #180120 SO MYLES iwas.BM.*w'rtw.W.W.73, PHOTOVOLTAIC EM COMBINER PANEL WITH RAPID SHUTDOWN 11 uaE o 0 DO NOT ADD LOADS CUSTOMER RESIDENCE: SCHUTTE FATIMA LABEL LOCATION INVERTER (EXT) SOLAR PANELS ON 25 MONROE LN,YARMOUTH, PHOTOVOLTAIC AC COMBINER(IF 41 APPUCABLE) ROOF MA,02673 PER CODE(S):NEC 2020,705.12(D)(2X3)(c( 3 TURN RAPID SHUTDOWN PV PRODUCTION METER SWITCH TO THE"OFF" foOLM..Sas TEL(774)368-5071 POSITION TO SHUT DOWN FUSED AC DISCONNECT APN:YARM-000067-000016 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE SERVICE ENTRANCE PROJECT NUMBER: e MAXIMUM AC OPERATING CURRENT:32.00 AMPS SHOCK HAZARD IN THE 223R-025FATI ARRAY. Ell I NOMINAL OPERATING AC VOLTAGE. 240 VAC DESIGNER: (415)580.8820 ex3 LABEL LOCATION 25 MONROE LN, YARMOUTH, MA, 02673 NITESH RANA AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OFINTERCONNE TION SHEET PER CODE(S)CNEC 2020:800.54 S I G NAG E LABEL LOCATION ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2020:705.10,710.10 DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV Al 12/142022 PER CODE(S):NEC 2020:890,58(C) PAGE PV-5.0 remyme_ i 067