Loading...
HomeMy WebLinkAboutBLD-23-003432 m %1- RECE VEFJ ONE & TWO FAMILY ONLY- BUILDING PERMIT _ Town of Yarmouth Building Department : ;;riii, 2 2022 t 1146 Route 28,South Yarmouth,MA 02664-4492 ;:'`,►" 508-398-2231 ext. 1261 Fax 508-398-0836 �At , —' — --I --`"�,� i +�1. DEPARTMEN i Massachusetts State Building Code,780 CMR , Building Permit Application To Construct, Repair, Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: )LQ-- -(4,3i4 Date Applied: -(d ✓ /2 7/ t Building_��� vial(PriyName) Signature Date SEC ION :SITE INFORMATION i 1.I Property Address: 66 North Rd 1.2 Assessors Map&Parcel Numbers 38 64 1.1 a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) i 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Zone: Outside Flood Zone? _ Public 0 Private 0 Check if yesO Municipal 0 On site disposal system El SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Odair Marques Yarmouth MA 02673 Name(Print) City,State,ZIP 66 North Rd (508)280-8216 luciagomesxavier@outlook.com No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction 0 Existing Building Owner-Occupied / Repairs(s)-❑ Alteration(s) VI Addition ❑ Demolition 0 Accessory Bldg. ❑ Number of Units ( Other lla Specify: Roof Mounted Solar 1 Brief Description of Proposed Work2: Installation of a interconnected, roof mounted, photovoltaic solar energy system consisting of 23 solar panels producing 8.97 Kw DC. NO ESS SECTION 4:ESTIMATED CONSTRUCTION COSTS. Estimated Costs: Item (Labor and Materials) Official Use Only 1.Building S 5247.00 1. Building Permit Fee:S 150 Indicate how fee is determined: I 0 Standard City/Town Application Fee 2.Electrical S12244.00 s 0 Total Project Cost (Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: S 4.Mechanical (HVAC) S List: C 1)(—If 1a 0 113 230 5.Mechanical (Fire $ Suppression) Total All Fees:$ Check No. Check Amount: Cash Amount: 6.Total Project Cost: S 17491.00 0 Paid in Full 0 Outstanding Balance Due: m 614 /e it Z, -R-E i V E y �3 ONE & TWO FAMILY ONLY-BUILDING PERMIT ___ -- Town of Yarmouth Building Department � :;. 2 D 2022 1146 Route 28, South Yarmouth,MA 02664-4492 ,:'`�"? 508-398-2231 ext. 1261 Fax 508-398-0836 '� `""�=''� Massachusetts State Building Code,780 CMR = DEPARTiV i iv l Building Permit Application To Construct, Repair, Renovate Or Demolish .. a One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: e( Q 3 -U LJ3 Date Applied: Al Building O eial(Pri ame) Signature Date SEC ION :SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 66 North Rd 38 - 64 1.l a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,154) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone: — Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Odair Marques Yarmouth MA 02673 Name(Print) City,State,ZIP 66 North Rd (508)280-8216 luciagomesxavier@outlook.com No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK''(check all that apply) New Construction 0 Existing Building Owner-Occupied Q� Repairs(s) 0 Alteration(s)VI Addition ❑ Demolition 0 Accessory Bldg. 0 Number of Units Other Specify: Roof Mounted Solar Brief Description of Proposed Work': Installation of a interconnected, roof mounted, photovoltaic solar energy system consisting of 23 solar panels producing 8.97 Kw DC. NO ESS SECTION 4:ESTi MATED CONSTRUJCTION COSTS • Item Estimated Costs: Official Use Only 1.Building $5247.00 1. Building Permit Fee:$ -Indicate how fee is determined: 2.Electrical $12244.00 ❑Standard City/Town Application Fee ❑Total Project Cost;(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 0(.4 .aa 3 323q 5.Mechanical (Fire Suppression) $ Total All Fees:$ Check No. Check Amount: Cash Amount: 6.Total Project Cost: $ 17491.00 0 Paid in Full 0 Outstanding Balance Due: X I 4-"4 ..._.« •t..1 i. t 2 SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-040622 08/01/2023 Stephen Kelly License Number Expiration Date Name of CSL Holder U List CSL Type(see below) 16 Parkway Rd. No.and Street Type Description Stoneham MA,02180 L` Unrestricted(Buildings up to 35,000 cu.ft.) CitytTown,State,ZIP R Restricted 1&2 Family Dwelling b , e, M Masonry RC Roofing Covering WS Window and Sidine SF Solid Fuel Burning Appliances 978 793-7881 eastmapermits@sunrun.com I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) HIC - 180120 10/13/2024 Sunrun Installation Services Inc./Stephen Kelly HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 21 Worlds Fair Dr. eastmapermits@sunrun.com No.and Street Somerset, NJ, 08873 978 793-7881 Email address City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes No Cl SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Sunrun Installation Services Inc./Stephen Kelly to act on my behalf,in all matters relative to work authorized by this building permit application. Odair Marques See Attached Contract 12/16/2022 Print Owner's Name(Electronic Signature) Date • SECTION 7b:OWNER!OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Stephen Kelly 12/16/2022 Print Owner's or Authorized Agen s Nam lectronic Signature) Date N ES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.aov/oca Information on the Construction Supervisor License can be found at www.mass.aov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" onr- Ctxnmonweatttl of Massachusetts COalatril0le Otvtsion of Professional LfCFnsure Unrestricted -Buildings of any use group*tech Contain Board of Budding Requtatrons and Standards less than 36,000 cubic feet(091 cubic meters)of enclosed spate. C S-040622 Ell,PIrNS.08/01 2023 STEPHEN A(!3e L Y 1111PARKWAIIROAD e STONEHAM tap 021101 . Failure to possess a arrest edition of the M4ssiVrMdta Commissioner Slate Building Code is cause for revocation of Ildsih eves. For information about this license Cap(017)727-3200 or visit wet rrnsagoie 1p1 r THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs and Business Regulation 1000 Washington ane,Et-Suite 710 Boston,Massact uSetts 02118 Home Improvement CAntractor Registration • -ype Supplement Card S MUS INSTALLATION SERVICES INC. Registration 180120 21 WORLDS FAIR OR Fzplration 10/13/2024 SOMERSET.NJ 08873 I ,- IIaeISe Adlreee reVS ReMeOttetl THE COMMONWEALTH OF MASSACHUSETTS Ores of Cuuunwe ARM&Bus:nese Rsgulsuon Regrir.Gon void for e.Nvfual free only iron Y HOME IMPROVEMENT CONTRACTOR explrseor:oats.If&Wild rant b: TYPE;0of5584nent Card Mc*of Consumer Aaeks end retiree ReSd&YeR 1000 W0Nnglon Seed-Stele 710 10012Er'jj i)100312024 Seston,MA 0211e SUNRUN INSTALLATION IleRV1903 INC. STEPHEN KELLY ✓ Z S BUSH STREET SUMS 1400 ���' ::a....- -- - SAN FRANCISCO.CA 114104 r N valid eyllf&out naluro Stephen A Kelly 695 Myles Standish Blvd Taunton MA 02780 TEL:978-793-7881 Email: eastmapermits@sunrun.com i i—.411 SUNRINC-02 LWANG2 ACCORD CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDD/YYYY) klkin.....----- 8/31/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER License#0C36861 CONTACT NAME: Walter Tanner Alliant Insurance Services,Inc. PHONE FAX 560 Mission St 6th Fl (A/C,No,Ext): (A/C,No): - - San Francisco,CA 94105 Ma:Walter.Tannerlalliant.com INSURER(S)AFFORDING COVERAGE NAM# INSURER A:Evanston Insurance Company 35378 INSURED INSURER B:James River Insurance Company 12203 Sunrun Installation Services,Inc INSURER C:American Zurich Insurance Company 40142 775 Fiero Lane,Suite 200 Ph#805-540-7643 INSURER D: San Luis Obispo,CA 93401 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN. THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS_ LIMITSREDUCED AND CONDITIONS OF SUCH POLICIES. SHOWN MAY HAVE BEEN BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL'SUBR' POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTR INSD WVD IMM/DDIYYYY) (MM/DO/YYYY) A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2,000,000 CLAIMS-MADE X'OCCUR MKLV5ENV103749 10/1/2022 10/1/2023 DAMAGETORENTED 1,000,000 PREMISES(Ea occurrence) $ _ — - MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $ 2,000,000 X POLICY! X PrP LOC PRODUCTS-COMP/OP AGO $ 2,000,000 X OTHER:Retention:$100,000 Per Project Agg $ 5,000,000 !. COMBINED SINGLE LIMIT AUTOMOBILE LIABILITY (Ea accident) _ $ 7 ANY AUTO BODILY INJURY(Per person) ,$ OWNED -1 SCHEDULED - - - AUTOS ONLY _-'AUTOS BODILY INJURY(Per accident) $ HIRED j NON-OWNED PJtOPERTY DAMAGE AUTOS OS ONLY —H AUTOS ONLY ( er accident) $ $ B j l UMBRELLA LIAB X OCCUR ! EACH OCCURRENCE $ _ _ 4,000,000 X EXCESS LIAB CL IMS-MADEI '001072261 10/1/2021 10/1/2022 AGGREGATE I$ 4,000,000 DED RETENTIONS i $ C 1 AND EMPLOYERS'COMPENSATION LIABILITY - X I STATUTE ER 1 PER ANY PROPRIETOR/PARTNER/EXECUTIVE Yr/; WC614287601 10/1/2022 10/1/2023 E.L.EACH ACCIDENT $ 1,000,000 QFFICER/MEM EXCLUDED? N N/A (mandatory in -—- I I 1 E.L.DISEASE-EA EMPLOYEE $ 1'000'OOO ) IIf yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ I I I DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule.may be attached if more space is required) Workers'Compensation Policy WC614287601 Deductible:$1,000,000. Re:Permitting within jurisdiction. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE own of Yarmouth THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 146 1 ow of Yam ACCORDANCE WITH THE POLICY PROVISIONS. 28 South Yarmouth,MA 02664-4492 AUTHORIZED REPRESENTATIVE i ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts Department of Industrial Accidents (_ ,p Office of Investigations '' , j Lafayette City Center 2 Avenue de Lafayette, Boston,MA 02111-1750 www.mass.gov/dia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name(Business/Organization/Individual): Sunrun Installation Services /Stephen Kelly Address:225 Bush St STE 1400 City/State/Zip: San Francisco CA 94104 Phone#: 978 793-7881 Are you an employer? Check the appropriate box: Type of project(required): I.® I am a employer with 50 4. ❑ I am a general contractor and I employees(full and/or part-time).* have hired the sub-contractors 6. ❑New construction 2. ❑ I am a sole proprietor or partner- listed on the attached sheet. 7. 0 Remodeling ship and have no employees These sub-contractors have 8. ❑Demolition workingfor me in anycapacity. employees and have workers' 9. ❑Building addition [No workers' comp. insurance comp. insurance.* required.] 5. ElWe are a corporation and its 10.0 Electrical repairs or additions officers have exercised their 11.❑ Plumbing repairs or additions 3.0 I am a homeowner doing all work myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.] t c. 152,§1(4),and we have no 1 i ®Other Roof Mounted Solar employees. [No workers' comp. insurance required.] *My applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. I.Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: American Zurich Insurance Company Policy#or Self-ins. Lic.#:WC614287601 Expiration Date: 10/01/2023 Job Site Address: 66 North Rd City/State/Zip: Yarmouth MA 02673 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby ceriilr under the pains and penalties of perjury that the information provided above is true and correct. Signature: ..Adryase a2, Date: 12/16/2022 Phone#: 978-793-7881 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(check one): 10Board of Health 21:1BuildingDepartment 31:City/TownClerk 4.0 Electrical Inspector S❑Plumbin;t Inspector 6.0Other Contact Person: Phone#: • Sunrun BrightSaveTM Agreement Odair Marques 66 N Rd, Yarmouth, MA, 02673 Take Control of Your Electric Bill $0 25 Years $210 $0.280 Deposit due Agreement Term Length Monthly Bill for Year Year 1 Cost per kWh Today (3.5% annual increase One (plus taxes, if applicable; (excluding upfront in monthly bill) includes $7.50 discount for payment, if any) Auto-Pay enrollment) WE'VE GOT YOU COVERED WITH OUR WORRY-FREE SERVICE C;) We provide hassle-free We monitor the system We warrant, insure, Selling your home? design, permitting, and to ensure it runs maintain and repair We guarantee the buyer installation. properly. the system. We will qualify to assume also provide a 10- your agreement. year roof warranty. A SOLAR SYSTEM DESIGN FOR YOUR HOME You get a 8.58 kW DC Solar System With 22 Solar Panels and 1 Inverter(s) Which will produce an est. 9,014 kWh in its first year And offset approx.103% of your current, estimated electricity usage YOUR SALES REPRESENTAT Felipe Ba felipe.barros@sunrun., (6117) 309-e } By signing below, you acknowledge that you have reviewed and received a complete copy of the Agreement without any blanks. Such Agreement shall be the complete understanding between the Parties. SUNRUN I a �dpN SERVICES INC. Signatur : �a dn,r a. /11.4 -u 25 E316CF746F6A484.. Print Name: Andres vasquez Date: 12/1012022___ Title: prnject nperatinns Federal Employer Identification Number: 26-2841711 IF YOU CHOOSE TO PAY BY CHECK, MAKE CHECKS OUT TO SUNRUN INC. NEVER MAKE A CHECK OUT TO A SALES REPRESENTATIVE. OUR SALES REPRESENTATIVES ARE NOT AUTHORIZED TO RECEIVE CHECKS IN THEIR OWN NAMES. YOU MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF THE TENTH EFFECTIVE DATE. PLEASE REVIEW THE ATTACHED NOTICES OF CANCELLATION FOR AN EXPLANATION OF THIS RIGHT. Customer ,Prirtanecount Holder Secondary Account Holder (Optional) `---38SWri11011 Odair Marques Signature 12/1/2022 Date Print Name Email Address*: luciagomesxavier@outlook.com Mailing Address: 66 N Rd Yarmouth, MA 02673 Phone: (508) 280-8216 Email addresses will be used by Sunrun for official correspondence such as sending monthly bills or other invoices. Sales Consultant By signing below/acknowledge that I am Sunrun accredited, that I presented this agreement according to CoStifienie Code of Conduct and that I obtained the homeowner's signature on this agreement. -6:_tli..pe, Bann.o. ti6A5 iUAr 3.. Felipe Barros Print Name 1442 318725 Sunrun ID number Sunrun Installation Services Inc. 1225 Bush Street. Suite 1400. San Francisco. CA 94104 I 888.GO.SOLAR I HIC §TOWN OF YARMOUTH 1146 Route 28, South Yarmouth, MA 02664 508-398-2231 ext. 1261 Fax 508-398-0836 Office of the Building Commissioner BUILDING DEPARTMENT DEMOLITION DEBRIS DISPOSAL AFFIDAVIT Pursuant to M.G.L. Ch. 40, §54 and 780 CMR- Section 105.3.1. #4. I hereby certify that the debris resulting from the proposed work/demolition to be conducted at 66 North Rd Work Address Is to be disposed of oat the following location: 695 Myles Standish Blvd. Taunton, MA 02780 Said disposal site shall be a licensed solid waste facility as defined by M.G.L. Ch. 111, §150A. 7 12/16/2022 Signs of Applicati Date Permit No. SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE N DESCRIPTION rag •SYSTEM SIZE:8970W DC.7680W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015IRCIIBC/IEBC), SERVICE ENTRANCE •MODULES:(23)TRINA SOLAR.TSM-390DE09C.07 MUNICIPAL CODE.AND ALL MANUFACTURERS LISTINGS AND INSTALLATION PV-1.0 COVER SHEET L J •INVERTERS:(1)DELTA ELECTRONICS:E8-TL-US INSTRUCTIONS, PV-2.0 SITE PLAN •RACKING:TOPSPEED,SEE DETAIL SNR-DC-30004 •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. • MP MAIN PANEL •RAPID SHUTDOWN:(23)APSMART RSD-S-PLC ROOFTOP PV-3.0 LAYOUT MODULE LEVEL RAPID SHUTDOWN DEVICE •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV-4.0 ELECTRICAL SP SUB-PANEL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-5 0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 0 SUNRUN METER •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM DEDICATED PV METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL 1R orAly, • CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). o46 MO°,�s,4„. 0 AC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). o� CIVIL�s N NO.58313 DC •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. ..,,i_ O DC DISCONNECT(S) le 90,T.'�msro- ,,A�e •13.35 AMPS MODULE SHORT CIRCUIT CURRENT. E.ss/ONAL00 CB IQ COMBINER BOX •20.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(8)). Esp:6/30/2024 •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). STAMPED 12115/2022 ABBREVIATIONS r-I INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE A AMPERE L J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ARC FAULTN CIRCUIT CURRENT s u n r u n AFC ARC FAULT CIRCUR INTERWTER � CHIMNEY AZW ALAIUTH COMP COMPOSII ION DC DIRECT CURRENT L ATTIC VENT #180120 IEI EXISTING = FLUSH ATTIC VENT VICINITY MAP OM MYLES STANpw KVD.TAUNIDN,M.017I3.O3 ESS ENERGY STORAGE SYSTEM O PVC PIPE VENT (wowa AAo EXT EXTERIOR S METAL PIPE VENT CUSTOMER RESIDENCE: INT INTERIOR ODAIR MARQUES MSP MAIN SERVICE PANEL ® T-VENT 66 N RD,YARMOUTH,MA.02673 IN) NEW - () SATELLITE DISH NTS NOT TO SCALE TEL.(508)280.8216 OC ON CENTER / FIRE SETBACKS APN:YARM-000038-000064 PRE FAS PRE-FASRICATED PROJECT NUMBER: I PSF POUNDS PER SOUARE FOOT HARDSCAPE aD N Rd,West 223R-O66MARQ PV PHOTOVOLTAIC Yarmouth• ,MP.02b73.. 2E DESIGNER: (415)580-6920 e03 ROO RAPID SHUTDOWNOEGICE —PL— PROPERTY LINE SOLAR MODULES WEST SUNIL KUMAR TL TRANSFORIiERLESN SCALE.NTS YARMOUTH SHEET ryP TYPICAL REV NAME DATE COMMENTS COVER SHEET V VOLTS W WATTS REV:A 12/14/2022 LAN LANDSCAPE POR PORTRAIT '---TOPSPEED MOUNT GullBr.:_• PAGE PV-1.O tonlyra_w,wn AV 87 _ a m N 0 m S H = N mH NRD u Hm vJ ry ma H °>O o z N m O .. - - al1111111111111111111 lot z 73 D D D 6 N m m z 0 m < s F F'NN N RD 0 R r \ N W 0 o6 my m ------A A rn n D m _, co)COA m 1 _c Z 3 m 1 .I, m < A \ / N V t O mD 0, m To 0 < m H Ph ZD AXIO i °gy m CZ T.m T. do ' . m ,3 qp mom v 'mN m 0 C u0. ONm N ^,; j$' ZEC ii A 1 o O O N N itN u W ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Minimum Number of Mounts per Up-Slope Max Landscape Max Portrait MAX DISTRIBUTED LOAD:3 PSF Span SpacingEdge Overhang Overhang SNOW LOAD:30 PSF WIND SPEED: AR-01 COMP SHINGLE- 1-Story 2X8 RAFTERS 5'-11" 20" TOPSPEED.SEE DETAIL SNR-DC-30004 2 1'-5" 0'-10" 140 MPH 3-SEC GUST. TOPSPEED S.S.LAG SCREW D1-AR-01-SCALE:1/6"=V-0" (4)1/4"WOOD SCREWS FULLY AZIM:97" PENETRATING THROUGH WOOC PITCH:26" DECK 4'-5 f. ____—__ _______... ..__.. ._. 34'-10^ _._._ _.________--__ __- __ I 40L1X OF bg444 .. or 0,:ovA44� PSG _____.. (Di CIVIL w. 0 0 �;. 0 0 0 0 0 0 0 0 0 0 N0.56313 "' o I FfS4lONALEt�C'`,A 0 -...0..—,ae. © — _,.0 0 0 Exp:6/30/2024 STAMPED 12/15/2022 0 0 0 0 0 0 0 0 0 14'_7" `un r u n 0 0 0 0 0 0 0 0 0 0 0 #180120 BM MYIES STAND EN BIM.IAU01000 MA.02700.1 0.0 CUSTOMER RESIDENCE. 0 0 0 0 0 0 0 0 0 0 �s 66 N R UES YAR RD.YARMOUTH,MA.02673 INSTALLERS SHALL NOTIFY ENGINEER OF ANY TEL.(508)280-8216 POTENTIAL STRUCTURAL ISSUES OBSERVED APN.YARM-000038-000064 PRIOR TO PROCEEDING W/INSTALLATION PROJECT NUMBER Hole. 223R-066MARQ MOUNT NUMBER FOR LEADING DOWN SLOPE EDGE SHALL DESIGNER (415)580-6920 ex3 MATCH REQUIREMENTS LISTED ABOVE SUNIL KUMAR INSTALL PER TOPSPEEDTM INSTALLATION MANUAL SHEET CONTRACTOR MAY SUBSTITUTE SNAPNRACK DECKTRACK LAYOUT MOUNTS (SNR DETAIL SNR-DC-00453)WITH MAX OVERHANG OF 6"h REV.A 12/14/2022 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 rempiN,wislwL a 087 120/240 VAC SINGLE PHASE SERVICE METER#: `--- O EVERSOURCE 2286670 1 TILITY NOTE:TOTAL PV BACKFEED=40A GRID I USED FOR INTERCONNECTION SUPPLY SIDE TAP CALCULATIONS 0 11 EXISTING 100A (N)LOCKABLE BLADE TYPE (N)MA SMART MAIN BREAKER FUSED AC UTILITY DELTA ELECTRONICS: DISCONNECT REVENUE E8-TL-US 1 METER 7680 WATT INVERTER JUNCTION BOX PV MODULES .` n TRINA SOLAR:TSM-390DE09C.07 () OR EQUIVALENT () AAXn _ PANEL 125A MAIN s // (23)MODULES `� „� O — `� +- . _( (1)STRING OF(8)MODULES �r (1)STRING OF(7)MODULES FACILITY LOADS Iwam 40A FUSES I t 1 (1)STRING OF(8)MODULES SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT (23)APSMART RSD-S-PLC MODULE D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN 3R.60A UTILITY SIDE OF CIRCUIT COMPLIANT LEVEL RAPID SHUTDOWN DEVICES 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (6)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (8)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 I s u n r u n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 ON Mall.SrMMSHt..T.WHraJ.W 027004331 MOM 0 {,u a CUSTOMER RESIDENCE: ODAIR MARQUES 66 N RD,YARMOUTH,MA,02673 MODULE CHARACTERISTICS TEL.(508)280-8216 TRINA SOLAR.TSM-390DE09C 07 390 W APN:YARM-000038-000064 OPEN CIRCUIT VOLTAGE 40.8 V PROJECT NUMBER: • MAX POWER VOLTAGE: 33.8 V 223R-O66MARQ SHORT CIRCUIT CURRENT: 13.35 A DESIGNER: (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 SUNIL KUMAR SYSTEM SIZE: 8970 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 361 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 270 V MAX ALLOWABLE DC VOLTAGE: 480 V REV A 12/14/2022 SYSTEM OPERATING CURRENT: 34.82 A SYSTEM SHORT CIRCUIT CURRENT 50.06 A PAGE PV-4-0 T npNS rflim_4 0 87 INVERTER 1 NOTES AND SPECIFICATIONS /"\WARN I NG •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 880,OR ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT IF REQUESTED BY THE LOCALAHJ. -- •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE 1,1A2V.1UF.I SYSTEM%,a Tr,GE 480 WORDS.COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN METHOD AND SHALL NOT BE HAND WRITTEN. LABEL LOCATION. •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT THE OPEN POSITION INVERTER(S),DC DISCONNECTIS). INVOLVED. PER CODE(S).NEC 2020.890.53 •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY LABEL LOCATION. SIGNS AND LABELS.UNLESS OTHERWISE SPECIFIED. INVERTERS).AC/DC DISCONNECT(S). •DO NOT COVER EXISTING MANUFACTURER LABELS. AC COMBINER PANEL(IF APPLICABLE). PER CODE(S)NFC 2020 690.13(8) WARNING:PHOTOVOLTAIC POWER SOURCE WARNING LABEL LOCATION DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT. SOURCES:UTILITY GRID AT EACH TURN.ABOVE AND BELOW PENETRATIONS. ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020,88031(0)(2),IFC 2012 SYSTEM 80511 1.4 A U T I N LABEL LOCATION. • UTILITY SERVICE METER AND MAIN ■ SERVICE PANEL. PER COL7EIS):NEC 2020:708.12(C) MULTIPLE SOURCES OF POWER it,WARNING POWER SOURCE OUTPUT CONNECTIONrSHUTDOWNSWITCH SOLARPVSYSTEMDO NOT RELOCATE THIS ,� OVERCURRENT DEVICE LABEL LOCATION. SOLAR PANELS • INSTALLED WITHIN 3'OF RAPID SHUT DOWN LABEL LOCATION'. SWITCH PER CODE(8).NEC 2020-890.58 ,1C)(2),IFC ON ROOF S u n r u n ADJACENT TO PV BREAKER AND ESS 2012 605 11 1,IFC 2018 1204.5.3 ' OCPD(IF APPLICABLE) • PER COOPS:NEC 202n ,1- 705.12(8)13g #180120 %\WARNING SOLAR PV SYSTEM EQUIPPED • "" PHOTOVOLTAIC SYSTEM MAIN PANEL (INT) "` '�'°���`���"�M�.•Y,.°�'tl'"" "'°'E°`° COMBINER PANEL WITH RAPID SHUTDOWN 55 DO NOT ADD LOADS CUSTOMER RESIDENCE: ODAIR MARQUES LAPEL LOCATION: • PHOTOVOLTAIC AC COMBINER(IF SERVICE ENTRANCE 86NRD,YARMOUTH,MA,02673 APPUCABLE). PER CODE(S):NEC 2020.705.12(D)(253)(c) 3" TURN RAPID SHUTDOWN SWITCH TO THE"OFF' •, TEL.(508)280-8216 POSITION TO SHUT DOWN APN:YARM-000038-000064 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE 1 PROJECT NUMBER: SHOCK HAZARD IN THE 223R-O66MARQ MAXIMUM AC OPERATING CURRENT:32.00 AMPS El INVERTER (EXT) NOMINAL OPERATING AC VOLTAGE: 240 VAC ARRAY. PV PRODUCTION METER FUSED AC DISCONNECT DESIGNER: 415)580-0B20 ex3 LABEL LOCATION. SUNIL KUMAR AC DISCONNECT(S).PHOTOVOLTAIC SYSTEM POINT OF 66 N RD, YARMOUTH, MA, 02673 SHEET INTERCONNECTION. PER CODES)'NEC 2020 690.54 LABEL LOCATION. SIGNAGE ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODES),NEC 2020:705.10,710.10 DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED, REV:A 12/14/2022 PER CODE(S):NEC 2020:890.56(C) PAGE PV-5.0 Iempele_.•non_e 0 87 Page 8 of 8 Odair Marques Current :newables Engineering Limits of Scope of Work and Liability: Existing structure is assumed to have been designed and constructed following appropriate codes at time of erection,and assumed to have appropriate permits.The calculations produced are only for the roof framing supporting the proposed PV installation referenced in the stamped planset and were completed according to generally recognized structural analysis standards and procedures, professional engineering and design experience, opinions and judgements. Existing deficiencies which are unknown or were not observable during time of inspection are not included in this scope of work.All PV modules, racking,and mounting equipment shall be designed and installed per manufacturer's approved installation specifications.The Engineer of Record and the engineering consulting firm assume no responsibility for misuse or improper installation.This analysis is not stamped for water leakage. Framing was determined based on information in provided plans and/or photos, along with engineering judgement. Prior to commencement of work,the contractor shall verify the framing sizes,spacings, and spans noted in the stamped plans,calculations, and cert letter(where applicable)and notify the Engineer of Record of any discrepancies prior to starting construction. Contractor shall also verify that there is no damaged framing that was not addressed in stamped plans,calculations,and cert letter (where applicable)and notify the Engineer of Record of any concerns prior to starting construction. 1760 Chicago Ave Suite J13, Riverside,CA 92507 info@currentrenewableseng.com (951)405-1733 • Page 1 of 8 Current Renewables Engineering 12-14-2022 Sunrun Inc. 595 Market St Attn.:To Whom It May Concern re job: Odair Marques 66 N Rd,West Yarmouth, MA 02673, USA The following calculations are for the structural engineering design of the photovoltaic panels and are valid only for the structural info referenced in the stamped plan set.The verification of such info is the responsibility of others. I certify that the roof structure has sufficient structural capacity for the applied PV loads. All mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Design Criteria: Code: 780 CMR, IBC 2015, ASCE 7-10, Live Load: 20 psf Ult Wind Speed: 140 mph Exposure Cat: B Ground Snow: 30 psf Min Snow Roof: 0 psf 12-14-2022 ,,EtH OF Moss 01v-,00VASs 4°4. 4 c CIVIL ti 00 Current Renewables Engineering Inc. " NO.56313 Professional Engineer ro °Fc,sTEaE°\���� info@currentrenewableseng.com Ffs L siONAENG Exp:6/30/2024 1760 Chicago Ave Suite J13, Riverside,CA 92507 info@currentrenewableseng.com (951)405-1733 Page 2 of 8 Odair Marques Current lll( Engineering Roof Properties: Roof 1 Roof Type = Shingle Roof Pitch (deg) = 26.0 Mean Root Height (ft) = 13.0 Attachment Trib Width (ft) = 3.3 Attachment Spacing (ft) = 2.8 Framing Type = Rafter Framing Size = 2x8 Framing OC Spacing (in.) = 20.0 Section Thickness, b (in) = 1.5 Section Depth, d (in) = 7.2 Section Modulus, Sx (in3) = 13.141 Moment of Inertia, lx (in ) = 47.635 Unsupported Span (ft) = 15.0 Upper Chord Length (ft)= 15.0 • Deflection Limit D+L(in)= 3.0 Deflection Limit S or W(in) = 2.0 Attachments Pattern = Fully Staggered Framing Upgrade = No Sister Size = NA Wood Species = SPF Wood Fb (psi) = 875.0 Wood Fv (psi) = 135.0 Wood E (psi) = 1400000.0 CD (wind) = 1.6 Cd (snow) = 1.15 Cis = 1.0 CM = C,= CL = C; = 1.0 CF= 1.2 Cfu = 1.0 Cr = 1.15 F'b wind (psi) = 1932.0 F'b snow (psi) = 1388.62 F'v wind (psi) = 216.0 F'v snow (psi) = 155.25 M allowable wind (lb-ft) = 2115.64 M allowable snow(lb-ft) = 1520.62 V allowable wind (Ibs) = 1566.0 V allowable snow (Ibs) = 1125.56 E' (psi) = 1400000.0 1760 Chicago Ave Suite J13, Riverside,CA 92507 info@currentrenewableseng.com (951)405-1733 Page 3 of 8 Odair Marques Current Renewables Engineering Load Calculation: Dead Load Calculations: Roof 1 Panels Dead Load (psf) = 3.0 Roofing Weight (psf)= 3.0 Decking Weight (psf)= 2.0 Framing Weight(psf)= 1.495 Misc. Additional Weight(psf)= 1.0 Existing Dead Load (psf) = 7.495 Total Dead Load (psf) = 10.495 Wind Load Calculations: Ultimate Wind Speed (mph) = 140.0 Directionality Facto r, kd = 0.85 Topographic Factor, kzt= 1.0 Velocity Press Exp Factor, kz = 0.701 Velocity Pressure, qz (psf) = 29.88 External Pressure Up, GCp_1 = -0.87 External Pressure Up, GCp_2 = -1.549 External Pressure Up, GCp_3 = -2.419 External Pressure Down, GCp = 0.44 Design Pressure Up, p_1 (psf) = -25.992 Design Pressure Up, p_2 (psf) = -46.299 Design Pressure Up, p_3 (psf) = -72.291 Design Pressure Down, p(psf) = 16.0 Snow Load Calculations: Ground Snow Load, pg (psf) = 30.0 Min Flat Snow, pf_min (psf) = 0.0 Sloped Snow, ps_min (psf) = 0.0 Snow Importance Factor, lc= 1.0 Exposure Factor, Ce = 0.9 Thermal Factor, Ct = 1.1 Flat Roof Snow, pf(psf) = 20.79 Slope Factor, Cs = 0.733 Sloped Roof Snow, ps (psf) = 15.245 1760 Chicago Ave Suite J13, Riverside,CA 92507 info@currentrenewableseng.com (951)405-1733 Page 4 of 8 Odair Marques Current int Engineering Attachment Checks: Roof 1 Attachment Type = Deck Mount Allowable Up Force (Ibs) = 210.0 Allowable Down Force (Ibs) = 210.0 Allowable Side Force (Ibs) = 115.0 Applied Uplift Force (Ibs) =-207.053 Uplift DCR =0.986 Applied Down Force (Ibs) = 177.41 Down DCR =0.845 Applied Lateral Force (Ibs) =73.902 Lateral DCR =0.643 1760 Chicago Ave Suite J13, Riverside,CA 92507 info@currentrenewableseng.com (951)405-1733 Page 5 of 8 Odair Marques OF Current :Lnewables Engineering Roof Framing Checks: Force Checks: LC1: D+S Roof 1 Applied Moment(lb-ft) = 1207.0 Applied Shear(Ibs) = 320.0 Allowable Moment(lb-ft) = 1521.0 Allowable Shear(Ibs) = 1126.0 Moment DCR = 0.793 Shear DCR = 0.284 LC2: D+0.6W Applied Moment(lb-ft) = 942.0 Applied Shear(Ibs) = 250.0 Allowable Moment (lb-ft) = 2116.0 Allowable Shear(Ibs) = 1566.0 Moment DCR = 0.445 Shear DCR = 0.16 LC3: D+0.75(S+o.6W) Applied Moment (lb-ft) = 1365.0 Applied Shear (Ibs) = 362.0 Allowable Moment (lb-ft) = 2116.0 Allowable Shear (Ibs) = 1566.0 Moment DCR = 0.645 Shear DCR = 0.231 LC4:o.6D+0.6W Applied Moment(lb-ft) = 745.0 Applied Shear(Ibs) = 198.0 Allowable Moment(lb-ft) = 2116.0 Allowable Shear(Ibs) = 1566.0 Moment DCR = 0.352 Shear DCR = 0.126 1760 Chicago Ave Suite J13, Riverside,CA 92507 info@currentrenewableseng.com (951)405-1733 Page 6 of 8 Odair Marques Current Renewables Engineering Deflection Checks(Service Level): LC1: D+L Deflection (in.) = 1.095 Deflection Limit (in.) = 3.0 Deflection DCR = 0.365 LC2:S Deflection (in.) = 0.434 Deflection Limit (in.) = 2.0 Deflection DCR = 0.217 LC3:W(Down) Deflection (in.) = 0.191 Deflection Limit (in.) = 2.0 Deflection DCR = 0.096 LC4:W(Up) Deflection (in.) = 0.311 Deflection Limit (in.) = 2.0 Deflection DCR = 0.155 1760 Chicago Ave Suite J13, Riverside,CA 92507 info@currentrenewableseng.com (951)405-1733 Page 7 of 8 Odair Marques Current .0 Engineering Seismic Check: Existing Weight: Wall Weight(psf)= 17.0 Tributary Wall Area (ft2) = 1040.0 Total Wall Weight (lbs) = 17680.0 Roof Weight (psf) = 7.495 Roof Area (ft2)= 2220.0 Total Roof Weight(Ibs) = 16639.594 Total Existing Weight(Ibs)= 34319.594 Total Additional PV Weight(lbs) = 1252.35 Weight Increase: (Existing W+Additional W)/(Existing W) = 1.036 The increase in weight as a result of the solar system is less than 10%of the existing structure and therefore no further seismic analysis is required. 1760 Chicago Ave Suite J13, Riverside,CA 92507 info@currentrenewableseng.com (951)405-1733 Page 8 of 8 OdairMarques 4.`.. Current Renewables Engineering Limits of Scope of Work and Liability: Existing structure is assumed to have been designed and constructed following appropriate codes at time of erection,and assumed to have appropriate permits.The calculations produced are only for the roof framing supporting the proposed PV installation referenced in the stamped planset and were completed according to generally recognized structural analysis standards and procedures, professional engineering and design experience,opinions and judgements. Existing deficiencies which are unknown or were not observable during time of inspection are not included in this scope of work.All PV modules, racking, and mounting equipment shall be designed and installed per manufacturer's approved installation specifications.The Engineer of Record and the engineering consulting firm assume no responsibility for misuse or improper installation.This analysis is not stamped for water leakage. Framing was determined based on information in provided plans and/or photos,along with engineering judgement. Prior to commencement of work,the contractor shall verify the framing sizes,spacings,and spans noted in the stamped plans, calculations,and cert letter(where applicable)and notify the Engineer of Record of any discrepancies prior to starting construction.Contractor shall also verify that there is no damaged framing that was not addressed in stamped plans,calculations,and cert letter (where applicable)and notify the Engineer of Record of any concerns prior to starting construction. 1760 Chicago Ave Suite J13, Riverside,CA 92507 info@currentrenewableseng.com (951)405-1733