HomeMy WebLinkAbout286 Old Main St plan 13WOOD FRAMING NOTES: u 1. FLOOR JOISTS AND ROOF RAFTERS SHALL HAVE THE FIRST TWO BAYS FROM EACH END, BLOCKED PERPENDICULAR TO THE FLOOR MEMBERS AT 4'-0" O.C. USING BLOCKING OF J EQUAL DEPTH TO JOISTS. FLOORS TO HAVE BAND/RIM JOIST AT ENDS TO PROVIDE LATERAL STABILITY. MID -SPAN BRIDGING AS REQUIRED PER CODE. 'EXCEPTION: WHEN AN u ATTIC FLOOR OR CEILING DIAPHRAGM IS USED TO BRACE THE GABLE ENDWALL, ADDITIONAL ROOF DIAPHRAGM BLOCKING IS NOT REQUIRED. z REFER TO PRODUCT DATA & CATALOGS FOR ADDITIONAL INSTALLATION REQUIREMENTS AND PERFORMANCE w z 2. IF USING TJI OR OTHER PROPRIETARY FLOOR FRAMING, z INFORMATION. W - m m tj 3. FLOOR SHEATHING TO BE NAILED AT 6"EDGE/12" FIELD w/ 8d COMMON (2 1/2"x0.131") MIN U.N.O. BY MANUFACTURER. z LLJ 4. WALL & ROOF SHEATHING TO BE FASTENED w/ 8d COMMON (2 1/2"x0.131") OR 10d BOX (3"x0.128") NAILS MIN, U.N.O. ON DRAWINGS. SHEATHING TO BE INSTALLED WITH FACTORY N 00 LONG DIRECTION PERP. TO FRAMING. SHEATHING THICKNESS TO BE 7/16" MINIMUM FOR EXPOSURE B (15/32" FOR EXPOSURE C), U.N.O. N 5. FOR ULTIMATE WIND SPEEDS ABOVE 130 MPH, NAILS FOR ATTACHING PANEL ROOF SHEATHING TO INTERMEDIATE SUPPORTS SHALL BE SPACED 6" ON CENTER FOR MINIMUM 48" DISTANCE FROM RIDGES, EAVES, & GABLE END WALLS, AND 4" ON CENTER TO GABLE END WALL FRAMING (GABLE RAFTER). 6. WOOD STRUCTURAL WALL PANEL JOINTS SHALL OCCUR OVER FRAMING. HORIZONTAL JOINTS SHALL BE BLOCKED w/ 2x TO MATCH WALL FRAMING. w 7. ROOF FRAMING SHALL HAVE SIMPSON H2.5A HURRICANE TIES FROM EAVE TO TOP PLATE PER MANUFACTURER. COLLAR TIES WITHIN UPPER 1/3 OR TENSION STRAPS REQUIRED AT RIDGE. NON-STRUCTURAL RIDGE BOARD IS GENERALLY ALLOWED WHEN ROOF PITCH IS STEEPER THAN 3:12 AND THE BEARING WALLS ARE CONTINUOUSLY TIED WITH CEILING JOISTS OR RAFTER TIES PER CODE. STRUCTURAL RIDGE REQUIRED FOR 3:12 PITCH OR LESS. IF USING A STRUCTURAL RIDGE, CEILING JOISTS OR RAFTER TIES ARE w TYPICALLY NOT REQUIRED. RAFTERS SHALL BEAR ON STRUCTURAL RIDGE DIRECTLY OR HAVE SIMPSON LRUZ HANGERS (OR APPROVED EQUAL) OR CODE APPROVED Q FASTENING METHOD CAPABLE OF A MIMIMUM OF 400 LBS REACTION LOAD, UNLESS HIGHER REACTION OTHERWISE NOTED ON PLANS. O w SHEAR WALL/WSP NOTES: zo PLYWOOD JOINTS: x EDGE NAILING AS 1. DOUBLE TOP PLATES TO BE NAILED w/ (3) 16d FRAMING NAILS AT 16" O.C. TOP Q INDICATED ON PLAN EDGE OF WSP SHALL BE ATTACHED TO UPPER TOP PLATE. w w o H 000 2. EXTERIOR WALL BOTTOM PLATES SHALL BE NAILED TO FLOOR OR SILL PLATE N o INTERMEDIATE BLOCKING: USING (3) 16d FRAMING NAILS AT 12" O.C., U.N.O. EDGE NAILING AS INDICATED ON PLAN 3. MINIMUM PENETRATION OF SHEAR WALL FASTENERS INTO FRAMING SHALL U BE 1 3/4" FOR 8d COMMON NAILS. - ------ ------ — ----- ----- 4. ALL WASHERS FOR ANCHOR BOLTS IN WOOD PANELS TO BE 3"x3"x0.229" —I (MIN) SQUARE U.N.O. EDGE OF ANCHOR BOLT PLATE WASHERS SHALL I - EXTEND TO WITHIN 1/2" FROM EDGE OF BOTTOM PLATE ON THE SHEATHED U 40- SIDE. SLOTTED HOLED WASHERS ARE STRUCTURALLY ACCEPTABLE FOR D n Lu APPROPRIATE FITMENT. 5/8" 0 ANCHOR BOLTS TO BE WITHIN 6"-12" FROM R// ll_J Q FIELD (INSIDE OF EDGES): ENDS OF SILL PLATES, U.N.O. 12" O.C. UNO OTHERWISE PLYWOOD TO RUN w/ O LONG DIRECTION SHEATHING NAILING KEY (INDICATED ON PLAN): z HORIZONTALLY, U.N.O. 6" PANEL EDGES ALL AROUND, 12" FIELD 6 12 (3) 16d NAILS @ 12" O.C. SILL PLATE INTO FRAMING. Project # 22.38 '(N OF ftelo. Date 11-7-22 MATTHEW Oy 4 4" PANEL EDGES ALL AROUND, 12" FIELDS SHAUN Drawn By MP 12 (3) 16d NAILS @ 12" O.C. SILL PLATE INTO FRAMING. u STRUCTURAL Cn Scale As indicated No. 57000 ADO 9�GISTEP����t� NAILING PATTERN DETAIL 3 3" PANEL EDGES ALL AROUND, 12" FIELD. FSS�ONAL 1 — 1-0ENG� 1 12 11 /07/2022 (4) 16d NAILS @ 12" O.C. SILL PLATE INTO FRAMING. S.2