Loading...
HomeMy WebLinkAbout7 Akins Ave septic planG (NOT TO FOR FUTURE LOCATI()�4' L Cos TO WITHIN 3' GRADE Lj - EXISTING j BEL) ROOM, PROPOSED 4 BEDROOM 28 2% SLOPE REQUIRED OVER SYSTEM N FLOW: 4 BEDROOMS 0 110 GPD 440 G'��D L A 440 GPD DESIGN FLOW MORTAR ALL 11TOP PRECA.'.3T EL. 13.96 COMPONEN�S (TYP.) &01 SEPTIC TANK. 440 GPD `2) NL RE -USE EXISTING 1000 GAL, SEPTIC TANK 7- Wei C C= EXISTING LEACHING: 0 01 0 3 n, 0 01 , ") " () n C� 0- 0 ;-, & 0 o 0 CJ _,c) UUUBLE WASHED ***INSTAL!..L' R _�"ALL G'_ w 3/4�-I-1/2' STONE &DES: 2 6 43 GPD E, DIFFUSORS WITH 2� STONE ALL ',0STING (3) FLOW DIFFUSORS-* c, �"o oc, 0 BOTTOM -6 C.74) 154 GPD 8-x 26 04 0"A INV, EL. PROPOSED (2 ADDITIONAL) FLOW DIFFUSORS MATCH EXISTING EXISTING TOTAL- 265 SIF� _.ER SHALL VERIFY THE LOCATIONS OF ALL BOTTom STOIjE APPROX. 13.42* UTILITIES A�v` ALL BUILDING SEWER OUTLETS AND ELEVATIONS F-LEV- 11,42 PROPOSED LEACHING - PRIOR TO INSTALLING, ANY PORTION OF SEPTIC SYSTEM SIDES: (Ij+& 2)j9_ 87 GPD "INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS BOTTOM x 159 _GPD SUITABILITY FOR RE -USE. REPLACE WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE 5.5' BOTTOM TH-1 PROPOSED TOTAL: 332 S.F� GPD LOCUS MAP CONDITIONS IF NOT SUITABLE NO GROUNDWATER FOUND NOT TO SCALE TOTAL- 197 + 246 4 43 0 P D Q) ASSESSORS MAP 61 PARCEL 6 ADD (2) 4x8' FLOW DIFFUSERS IN[TH 3.5' STONE y, L E G' E BELOW ALL AROUND AND 1�04' 99 EXISTWO CONTOUR Jell% L NOTES X 99- EXIST. SPOT ELEV, IS NGVD 1. DATUM PROPOSED CONTOUR 0 1 MUNICIPAL WATER IS EXISTING 7MY Q MA A,PPROVED DATE BOARD OF HEALTH 3. MINIMUM PIPE PITCH TO BE 1/8- PER FOOT, PROPOSED SPOT EL, THI or- 4. DESIGN LOADING FOR ALL PROPOSED PRECAST TEST HOLE -JQ UNITS TO BE AASHO H ?:/t- SLOPE OF GROUND SEPTIC ADDITION DETAIL 5� PIPE JOINTS TO BE MADE WATERTIGHT. `0 6� CONSTRUCTION DETAILS TO BE IN ACCORDANCE r-c),., UTILITY POLF- tk W H 310 CMR 15.000 (TITLE 5.) VAP 5 T 01 FIRE HYDRANT FARCE� 7 7� THtS PLAN IS FOR PROPOSED WORK ONL:Y AND N07F-- NOr ALL SYMBOLS M4Y APPEAR 114 (hV1 AA0A1 NOT TO BE USED FOR LOT UNE STKYWAG OR ktV OnAkyw"ImW OTI-IER PURTS 1711- NOR' '21 R 8. PIPE FOR SEP77C SYSTEM TO SCH. 40�4' PVC� (1% K 9. COMPONENTS NOT TO BE BACKFILLED OR -XI's TING 0 JG7,7, �­ Ht, G CONCEALED MTHOUT INSPECTION BY BOARD OF lk �� "A - L 0 j HEALTH ANDPERMISS1,0N, OBTAINED,FR OF HEALTH. R m 5; J DANIEL E. GONSALVES, SE #13587 r, ENGINEER: 10. CONTRACTOR SHALL BE RESPONSIBLE FOR AMY VON H0111NIE, RS WITNESS: 51, Cl CALLING DIGSAFE (1-888-344-72 33) AND VERIFYING THE LOCATION OF ALL UNDERGROUN DATE. —.�/ 161�1 . ..... OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. r7 PERC, RATE '00 011-610, < 2 INCH �Z It ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. ?U, LS /0 I OYR 3/2 P41'CEL 6 3, 4.r, .:t TITLE 5 SIT�or--' 2 OF L �j 07 �01 < 'W10YR 4,;r4� 7 AKIN A"ENUE NJ, BENCHMARK' NA y Uu ri "UTH '"ARM"" "T" MA SET IN J6* TREE 17.74 IrNGVD) PREPARED FOR eeo ExIsr1w; P0Sr&R1V/, �ANN LEONAR rENCE 61 APRIL 21 2015 (#'4,1 pjE,4,�Aj1vr ST.) DATE. A�� REV: MAY 29, 2015 (SAS DF 24 TOCE -TAIL) 'All UIF DANIELA. M, 7­-_-7 g, �;F OJALA Off 508-362-454.1 fOx 508-362-9880 N 40980 GIVIL downcape,com No, 46502 11 V is 1 210 SURN eftg ee V_ FI Inc. civil engineers land surveyors AlOin Stree t 0 FEET to -TE DA YIA A 02