Loading...
HomeMy WebLinkAbout23-A046 970 Route 6A ApprovedYARM �I T N OW 1 �1�F �V TOWN OF YARMOUTH M N-09.0 - N5I R FC 1146 ROUTE 28, SOUTH YARMOUTH, MA 02664-4451 Telephone (508) 398-2231 Ext. 1292--Fax (508) 398-0836 S HIGHWAY HISTORIC DISTRICT COMMITTEE APPLICATION FOR CERTIFICATE OF APPROPRIATENESS Application is hereby made for issuance of a Certificate of Appropriateness under Section 6 of Chapter 470, Acts of 1973 as amended, for proposed work as described below & on plans, drawings, photographs, & other supplemental info accompanying this application. PLEASE SUBMIT 4 copies OF SPEC SHEET(S), ELEVATIONS, PHOTOS, & SUPPLEMENTAL INFORMATION. Check All Categories That ApggPe COO ii type of Building: Commercial —A/— Residential 1) Exterior Building Construction: New Building Addition Alterations Reroof Garage Shed Solar Panels Other: 2) Exterior Painting: Siding Shutters V Doors Trim Other; 3) Signs/Billboards: New Sign Change to Existing Sign 4) Miscellaneous Structures: Fence Wall Flagpole Pool Other: Please type or print legibly: Address of proposed work: 970 Route 6A Yarmouth Port MA 02675 MapJLot # 151 180.3 Owner(s): Peter & Carol Keefe Phone #: 774-994-0529 All applications must be submitted by owner or accompanied by letter from owner approving submittal of application. Mailing address: 970 Route 6A Yarmouth Port MA 02675 Year built: 1995 Email: pckeefel207@gmaii.com Preferred notification method: Phone V Email Agent/contractor: Sand Dollar Customs 1 Walter R. Waren, Jr. Phone #: 508-694-5618 Mailing Address: 259 Great Western Rd Unit B South Dennis MA 02660 ` / Email: office@sanddollarcustoms.cofm Preferred notification method: Phone v Email Description of Proposed Work: Master bedroom addition, and one garage bay addition. Re -roofing, re -siding, new windows and doors throughout. Signed (Owner or agent): l:t)aAZ4, X-9 L a t4a Date: 414123 ➢ Ownerlcontractortagent is aware that a permit is required from t Building Department. (Check other departments, also.) ➢ If application is approved, approval is subject to a 10-day appeal period required by the Act. ➢ This certificate is good for one year from approval date or upon date of expiration of Building Permit, whichever date shall be later. ➢ All new construction will be subject to_!pspection by OKH. OKH-approved plans MUST be available on -site for framing & final inspections. Rcvd Date: `'f Amount r Cash/CK #: Rcvd by: L, 51 45 pays: Approved Approved with _Modifications Denied Reason for Denial: Date Signed: L '�' 4ya TTOWN OF YARMOUTH OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE 1 146 ROUTE 28, SOUTH YARMOUTH, MASSACHUSETTS 02664-4451 Telephone (508) 398-2231 Ext.1292 Fax (508) 398-0836 STATEMENT OF UNDERSTANDING CHANGES TO AN OLD KING'S HIGHWAY APPROVED PLAN As property owner/contractor/agent for construction at 1-7 0y2bt/k Map/Lot CIA # a'? 3 _L{ Approval Date: I certify that I understand the following requirements regarding any changes that may be required for this project: In accordance with paragraph 2(a) of section 1.03(General Procedures) of the OKH 972 CMR Rules and Regulations: Only minor changes may be approved by the Committee without the filing of a new application and a new hearing. Minor changes include alterations that can be done without a detrimental impact on the overall appearance of the project such as altering a single window or door change or a minor change of colors. All minor changes by amendment will require the local Committee's or its designee's approval. All changes to previously OKH approved plans require notification to and approval from the local OKH Committee. Change requests must be submitted to the Committee in writing on the appropriate request form, which may be obtained from the OKH office. All change approvals must be obtained before incorporating the change into the project. If the change has been implemented prior to receipt of OKH approval, a Minor Change approval or Certificate of Appropriateness application for the revised plans is still required and will result in a doubled filing fee for the appropriate category of work. Failure to comply with the above statements will result in the Building Department issuing a stop -work order or delaying issuance of an Occupancy Permit or final inspection approval. have read and understand the above stat Date: Signed: A�� �Ell MAY 0 8 2023 Signed: YARMOUT� ,A,nv HAOKH COMMITTEDApplication FormslStatement of Understanding 2015.docx (Chairman, Old King's Highway Committee) Updated 12t2015 GENERAL SPECIFICATION SHEET Pro'ect Address: FOUNDATION: Material: 3" Concrete slab on 10 mil vapor harrier an 6" compacted gravel base Exposure (Not to exceed 18"): CHIMNEY: Material/Color: existing GUTTERS: Material/Color: White Aluminum ROOF: Material: Asphalt Pitch (7112 min) Height to Ridge: .. _ . Color: Moire Black SIDING: Material/Style: Front: Cedar Shake Sides/Rear: Cedar Shake Color: Front: Sides/Rear: Unfinished 6VIGz TRIM: All windows &doors to be trimmed with: 1x 4 0(Circle one.) Material: Azek Composite Color: White DOORS: Qty: 2 Material: Fiberglass color: Heritage Red Style/Size (if not listed/shown on elevations): Also, 1 slider door, Vinyl STORM DOORS: Qty: 2 Material: Aluminum Color: White GARAGE DOORS: Qty: 2 Mat'I: Galvanized Steel Style: Colonial Color: White WINDOWS: (side:: Front: 11 Left: 1 Right: 5 Rear: 5 Color: Black Manufacturer/Series: Harvey Classic Material: Vinyl - New Construction Grilles (Required): Pattern (616, 211, etc.) 6l6 Grille Tvpe: True Divided Lite: Snap -In: Between Glass: V Permanently Applied: Exterior Interior STORM WINDOWS: Qty: Material: SHUTTERS: MatT Color: Style: Paneled Louvered Color: SKYLIGHTS: Qty: Fixed Vented Size Color: COLOR CHIPS HECEIVED APR 14 2023 DECK: Size: Decking Mat'I: Color: Railing Mat'I: Style: Color: WALLSIFENCES* (Max 6' height): Height: Mat'I: Style: Color: (Show running footage & location on plot plan.) *Finished side of fence must face out from fenced in art UTILITY METERSIHVAC UNITS: Location: LIGHTS: Qty: Style: Location(s): LIGHT POSTS: Qty: Material: Location(s): Additional information: Screening: Color: 1 Zd r W. (AHMOUTh 2-General ` APPLICATION #: -, ''Aj- —" i(� & Telephone (508) 398-2231 Ext. 1292 Fax (508) 398-0836 OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE 45-DAY TIMEFRAME RECFIVED WAIVER APR 14 2023 Y AniviuU'l j Application #: q- Project Address: 970 Route 6A Yarmouth Port MA 02675 Application Received Date: /`� 2 45 Day Decision Deadline: a I/We, the undersigned owner, contractor, or agent, do hereby waive the 45-day timeframe for a determination on our application for a Certificate of Appropriateness/Demolition/Exemption by the Old King's Highway Historic District Committee for the following project: Date: 4/11 /23 Sighed: (see attached authorization) Owner Peter & Carol Keefe Owner 6(Jaa,4.140-- Contractor/Agent APPROIJ mAy 0 8 2023 rANMUOTl TOWN OF YARMOUTH OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE 2023 MEETING SCHEDULE TOWN OF YARMOUTH OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE ABUTTERS' LIST Applicant's (Owner) Name: Caiw �- (--?�W 1 Property Address/Location: q'7D C6&k 6A Hearing Date: �� rjg3 Notices must be sent to the applicant and abutters (including owners of land on any public or private street or way) whose property directly abuts or is across the street from the applicant. The OKH Office will send out notices using the addresses as they appear on the most recent applicable tax list. Note: Instructions for obtaining the abutters Map and Lot numbers can be found on the Old King's Highway Department page on the Town website: www.yarmouth.ma.us Map Number Lot Number Applicant Information Abutter Information: RECEIVED APR 14 2023 YARMOU*I-h APPROVED MAY 0 8 2023 YARMOU.'T IS r 1-7 3�3 ISI �D, �2 f 130 ,?- 0 13 `7 a� i 1'38 w, � as Application #: �1 31Jfib14 L 8.2018 3 TOWN OF YARMOUTH 1146 ROUTE 28, SOUTH YARMOUTH, MASSACHUSETTS 02664-4451 1511 1381 1 1 SHEA JOHN S JR SHEA MARGARET M 18 CAMPION RD YARMOUTH PORT, MA 02675-1560 1511 1371 1 1 VERMETTE RICHARD R VERMETTE KIM B 22 CAMPION RD YARMOUTH PORT, MA 02675-1560 1511 1411 1 1 CURRAN MICHAEL J CURRAN SUSAN M 9 MAPLE ST MEDFIELD , MA 02052 1511 851 1 I GONZALEZ DERAS JOSE M CHAY DE GONZALES NATALIA G 50 BOLSTER ST BOSTON , MA 02130 1511 841 I 1 MANLEY DAVID E TRS MANLEY G SUSAN TRS 23 BAYRIDGE DR YARMOUTH PORT, MA 02675 1511 1391 1 ! CYR JOAN M 14 CAMPION RD YARMOUTH PORT, MA 02675 151/ 80.21 I 1 TORRES-AYALA HECTOR E TORRES-AYALA CHIARA D 972 ROUTE 6A YARMOUTH PORT, MA 02675-2125 1511 80.31 1 I KEEFE PETER D AND CAROL TRS 970 ROUTE 6A, YARMOUTH PORT, MA 02675 1511 80.41 I ! BASILI BRIAN A BASILI SUSAN M 968 MAIN ST YARMOUTH PORT, MA 02675-2125 1431 105.41 / ! LANE KAREN V 979 ROUTE 6A YARMOUTH PORT, MA 02675 Please use this signature to certify this list of properties directly abutting and across the street from the parcel located at: 970 Route 6A, Yarmouth Port, MA 02675 Assessors Map 151, Lot 80.3 Andy Wichado, Director of Assessing April 25, 2023 F%EcFi%JEI) APR 2 5 2023 YARMOUlr OLD KING'S HIGHWA" APPROVED MAY 0 8 2023 YARMOUTH OLD KING'S HIGHWAY til L11 Oq ` A:, .� (i ri it1 ri 4 p to Ln OD M wLn O Q/ O M O �M �VwS CR Ito g o m Lm ND ri Z j $ 6 + U� Ln rN 1f1 S g l �•• Lti N 9 dgF S zp ze 'a APPROVE[ MAY 0 8 2023 YARMOUTh a N cu Yl Y d c m O RECEIVED APR 14 2923 OLD KING'S HIGHWAY__ 0 08 J N � %% W i'•' q al t �i ANN �=w APPROVE_ - MAY 0 8 2023 - YARMUU-f 1-1 ! ZD �C 1VED APR 14 2023 r Hn4ViUU l r , Z z pip O_ -1 3 4 N 0 0 Xi O x S � pK Ge M O �n O Qd II 0� N -i N m •+ Q m c� p w 7 APPRO-1'Ep MAY 0 S YARMOUT QING'S H K' � 3-- O RECEIVED r N yVj W rG iNj i U N Q u APR 14 2023 ip ran V �g YAHMOU i h E� OLD KING'S HIGHWAY o Z oa�a a WsA e O t Mill 'ItEI:o00 � ---- ------ ❑ao I I I I I �I I EII i I al I � I e a I 9 J�. I a 5 I L I I 3o y�` btl I I APPROVE MAY 0 8 2023 YARMOUTh OLD KING'S HIGHWAY F LL r------ ----- --� k I I I I I I !tl I 1 — — — ---'— — — — — — — - i I l i ilb �? II II I I I Ll .o■ , RECEIVED § APR 14 2023 § &� YAhMOUIh O KING'SHIGH&AY / Z In! \ h| � § �� ! )| A��R /g UAY O R 202 \ § Y RMOUTH OLD KINGS HGH&A \!El !! u � � ! - � 2 | - � -----------------------182023 ---- - 4 1'ARMUU h Ln OLD KINGS HIGHW 4 2023 r APR � W LL HhWVUU HIGH,) p tit z LD KING S__._.��, O g R I I I � n /� , I V I n V p � •-� � I I � I I 1 d I Y A� � LL � I. � ,�L•h' x x ci? w s —7bJf I z � I _ _ Y � ❑ � � � r�' W 4 � I A d s -rli 1 ^I � 41 LONGFELu LOW od LLJ I ,I �i• � ^ d /��/ d it •\ P p A �. T�8 CR 'Z GE�Gk •� z 1 \ I I ------ � 1 a ra H WLn T C0 H F- 0� Q a F LL D O U Z W J m 1f ~ I" Z m z�• z z y wy w� O�j y0� w j imp � =�z a oz � 4Zr p NZ o OoD F OWN o ?aa APR Y 4 2023 AnIVIOUTH APPROVED MAY 0 8 2023 YARMOUTH 0 %oq?w, RF-CLI Y ED OR 14 2023 "HMOUl r, APPROVED MAY 0 8 2023 YARMOU I H a3 --Tb4, F CEIVED APR 14 2023 (AhIVlouih APPROVED MAY 0 8 2023 rARMOUTH a�,fC 4, �_..�-'�_ __. �w ram•^ ifi '._•� F fir" -_ - Jw t PFCEIVED i APR 14 2023 eiHMOUTh OLD KING'S HIGHWAY APPROVED MAY 0 8 2023 YARMOUTH APPROVED MAY 0 8 2023 YARMOUTH D KINGS HIGF RECEIVED APR 1. 4 2923 Y AN IVILit1-!.r CING'S HIGF -3 3 -- Atgk heritage red BejsminMOor0 benjamin moore CHANTILLY LACE OC-65 HC-181 SBC CEDAR SHINGLES IN CAPE COD GRAY R: ^FI D A F R 14 2023 +mnlvtOLITh APPROVED MAY 0 S 2023 YARMOUTH IIIIJr+'n i —, Black Windows, White Trim, CC Gray Shingles Roof to Match Existing REr,#I D APB F 4 2023 rANVIOUTh APPROVED MAY 0 S 2023 YARMOUTH 33--/Iu Variable width 3-7/16"to 12" FACE om i-1/2" 116" Nail line 6-1/8" 900 Image not to scale 1/26" SIDE -*I I+-- 3/8" EDEIVED APR 1. 4 2023 SBC YAHM�LH-IG_M U'1 r�l D KING'SAY CEDAR GENERAL SPECIFICATIONS Thuicr occidentalis Eastern White Cedar SBC standards exceed CSA o118.2-Fo8 (C2018) SBC cedar shingles are graded on both faces - Solid - Weather*"ROVEC - Primer - Semi -Tr a spa It y 0 8 2023 - Natairai+r�na ro YARMOUTH Sidewad No imperfection 3/8" 3-7/16" to 12' 16" Siding Select AB on the exposed surface. (9.5 mm) (87 mm to 303 mm) (4o6 mm) Blend of grade Extra A and Clear B optimizing shingles width OTHER GRAOESAVAILABLEONDEMAND FACTORY STAIN APPLICATION - STAINED ON ALL SIDES Solid hipping PPG Machinecoat" 100% acrylic Hot Air/Oven Semi -transparent Dipping PPG Machinecoat'O H_ J 100% acrylic Hot Air/Oven Pro -Prime Dipping PPG Machinecoatl Hot Air/Oven 100% acrylic Enviro Bleach Dipping Hybrid Hot Air/Oven 1 Coat - 10 Years z Coats - 25 Years 1 Coat - 5 Years N/A 30 years against wood N/A decay Weathering Stain Impregnation Oil Air circulation N/A Bleaching Oil impregnation Oil Air circulation N/A Naturaltone Cedar Impregnation OIL Aircircutation N/A 'Against flaking and peeling, See more details on SBCcedar.com in the Warranty section f NED■ in COVERAGE TABLE 4" (102 mm) 20 sq.ft (1.9 mZ) 4-1/2" (114 mm) 22 sq.ft (2.1 m2) — -- 5"' (127 mm) 26 sq.ft (2.3 M2) 'Maximum recommended To calculate the number of boxes needed. add 5% to the area to cover. MANUFACTURING • Cedar logs are selected from responsible forest management based on the best quality and size available. • Use of stellite-tipped bladesfor a smoother surface and minimized raised grain. • Laser -guided precision edging for superior quality. Use of artificial vision system to measure and recut each shingle with an accuracy of 1/64" (0.4 mm) to obtain perfectly parallel sides and perpendicular butt. Embossed nailing line at 6-1/8" (156 mm) from the butt on one side for easy fasteners alignment. • Dehumidification drying process between 10% and 14% moisture content to optimize wood stability and maximize coating adhesion. FACTORY -STAINING APPLICATION METHOD Dipping (acrylic products): Exclusive dipping process followed by hot air drying to ensure unparalleled uniformity and a thicker film on the exposed surface. impregnation (ail -based products): Exclusive impregnation flood coat and brushing process followed by ambient air circulation to ensure maximum penetration into the wood. TYPE OF FINISH DETAILS PPG Machinecoat® 100%acrylic: Superior quality finish for factory application under optimal conditions; Its flexible film resists peeling and flaking. Enviro Bleach: Hybrid low VOC weathering agent that contains fungicide and wood preservative agents. Its hybrid technology delivers the look of oil -based products with the performance and environmental benefits of water -based coatings. Weathering stain & Bleaching oil: Linseed oil -based weathering agent that penetrates the wood and accelerates the cedar natural aging process. • Naturaltone Cedar: PPG/Olympic Maximum® 57503 oil -based toner that penetrates the wood and leaves a lightly tinted appearance on the surface. INSTALLATION Refer to the SBC instatlation guide before starting a project. Download the SBC installation guide Make an informed choice Our experts wilt answer your technical or aesthetic questions. Contact an SBC expert LEED 1NR �N MF V`•1 v01r.. aPPROVI MAY 0 S 20K eARMOUTH UI :D KING'S HIGHV SBC cedar shingles coutd help you earn LEED® points. For more information, see our Whv SBC - Sustainability section on SBCCedar.com. RMERIVED APR 14 2023 f AHMOIJ i 1­1 OWN —NG—SHIGHWAY LLS SBC L= CEDAR 9 5-fV-Ao ;RCcedar.com 0 In a ffHARVEY ARVEY 0 Wv WINDOWS + DOORS SECTION 08560 VINYL WINDOWS Display hidden notes to specifier. (Don't know how? Click Mere) Copyright 2006 - 2022 ARCAT, Inc. - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. Vinyl windows for new construction. 1.2 RELATED SECTIONS A. Section 03300 - Cast -In -Place Concrete. B. Section 04810 - Unit Masonry Assemblies. C. Section 06100 - Rough Carpentry. D. Section 06200 - Finish Carpentry. E. Section 07460 - Siding. 1.3 REFERENCES 1 4 2023 APPROVED MAY 0 8 2023 YARMOU t h A. American Architectural Manufacturers Association (AAMA): 1. AAMA/WDMA/CSA 101/I.S.2/A440-05, A440-08, A440-11 and A440-17 - NAFS - North American Fenestration Standard Specification for windows, doors, and skylights. 2. AAMA 701/702 - Combined Voluntary Specifications for Pile Weather strip and Replaceable Fenestration Weather seals. 3. AAMA 902 - Voluntary Specification for Sash Balances. B. ASTM International (ASTM): 1. ASTM E 283 - Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen. 2. ASTM E 330 - Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference, 3. ASTM E 547 - Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Cyclic Static Air Pressure 08560-1 0-CEIVED Difference. APR 14 2023 4. ASTM E2190 - Standard Specification for the Classification of the Durability of rANIVIU0Th Sealed Insulating Glass Units. OLD iClidG'S H4GHWAY5 Resist Resistance of Window Assem- Standard Test blies, Excluding Glazing Impact. Forcedods for Measuring the Entry C. NFRC 100/200/500 - Procedures for Determining Fenestration Product U-Factors, Solar Heat Gain Coefficient (SHGc), and Visible Transmittance at Normal Incidence (VT). APPROVED 1.4 SUBMITTALS A. Submit under provisions of Section 01300. MAY a 8 2023 YARMOUTH B. Product Data: Submit the following documents for each type of window. 1 OLD KINGS HIGF, 1. Manufacturer's technical data, product descriptions and installation guides. 2. Elevation for each style window specified indicating its size, glazing type, muntin type and design. 3. Manufacturer's head, jamb and sill details for each window type specified. C. Verification Samples: Operating units of each style window specified. 1. Verification samples may be operating scaled -down mock-ups of actual -size units. 2. Operating hardware such as balances, sash locks and weather-stripping. 3. Verification samples will be returned to manufacturer's representative at project closeout. D. Test Reports: Certified independent testing agency reports indicating window units meet or exceed specified performance requirements. 1.5 QUALITY ASSURANCE A. Manufacturer Qualifications: Minimum ten years producing vinyl (PVC) windows. B. Installer Qualifications: Minimum 2 years of experience on projects of similar size and acceptable to window manufacturer. C. Source Limitations: Obtain window units from one manufacturer through a single source. D. Testing: Provide window units independently tested and found to be in compliance with AAMA/WDMA/CSA 10111.S.21A440-05, A440-08, A440-11 or A440-17 performance standards. E. Code Compliance: Provide windows that are labeled in compliance with the jurisdiction having authority in the location of the project. F. Mock -Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship. 1. Finish areas designated by Architect. 2. Do not proceed with remaining work until workmanship and color are approved by Architect. 3. Rebuild mock-up area as required to produce acceptable work. 1.6 DELIVERY, STORAGE, AND HANDLING A. Deliver windows to project site in undamaged condition; handle windows to prevent damage to components and to finishes. 08560-2 a3 ,-M`k B. Store products in manufacturer's unopened packaging, out of direct sunlight or high APR ,temperature locations, until ready for installation. 5 TAI-tVA10 I r, PROJECT CONDITIONS OLD KING'S HIGHWAY A. Maintain environmental conditions (temperature, humidity and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's recommended limits. 2.1 MANUFACTURERS A. Acceptable Manufacturer: Harvey Building Products, which is located at: 1400 Main St.; Waltham, MA 02451-1689; Tall Free Tel: 800-598-5400; Tel: 781-398-7800; Fax: 781-398-7749; Email: request info (arch itectsccDharveybp.com); Web: httr)s://www.harveywindows.com B. Requests for substitutions will be considered in accordance with provisions of Section 01600. Substitutions must be submitted to Architect two weeks prior to bid opening. 2.2 NEW CONSTRUCTION CLASSIC DOUBLE HUNG WINDOWS A. Construction: 1. Frame: 0.065 inch (1.7 mm) thick polyvinyl chloride (PVC) with miter cut and fusion welded corners. Sash: 0.060 inch (1.5 mm) thick polyvinyl chloride (PVC) with miter cut and fusion welded corners. 2. Glazing: Insulating glass units secured to sash frame using a silicone sealant and exterior glazing bead. Complies with ASTM E2190, 3, Sash Balances: Factory calibrated block and tackle, complying with AAMA-902. Balance cords shall be anchored to locking terminal housings when the sash is tilted in. The locking terminal and pivot bar system shall provide accurate alignment of the sash and the frame during operation. 4. Sash Locks: Cam type lock anchored with screws. Double locks when openings are 30 112 inches (774 mm) wide and greater. /► 5. Weather Stripping: In compliance with AAMA 701.2. APPROVED B. Performance: MAY 0 8 2023 1. Forced Entry: Type B, Grade 10 in accordance with ASTM F 588. YARMOUTH PART 3 EXECUTION OLD KINGS HIGHWAY 3.1 EXAMINATION A. Verity rough opening size is of sufficient size to receive window unit and complies with manufacturer's requirements for opening clearances. Verify sill plate is level. 8, Notify Architect of unacceptable conditions before proceeding with installation. 3.2 INSTALLATION A. Install window unit in accordance with manufacturer's printed instructions including the following: 1. Apply sealant around perimeter of window unit between nail fin and exterior sheathing of wall. Refer to Division 7 Section "Joint Sealants". 2. Install window unit square, level and plumb. Center window unit in opening and secure window unit by nailing through nail fin and screw through jambs 08560-3 a;f11b4b as indicated in manufacturer's instructions. Flash window in accordance with AAMA's "Standard Practice for Installation of Windows with a Mounting Flange in Stud Frame Construction". Insulate between window frame and rough opening with insulation. Refer to Division 7 Section "Building Insulation". 010�=19a1:&mU9 0 A. Adjust units for smooth operation without binding or racking. Adjust sash locks and screens for smooth operation. 3.4 CLEANING AND PROTECTION A. Clean soiled surfaces and glass prior to substantial completion. B. Protect window unit from damage until substantial completion. Repair or replace damaged units. VIFCEI'VGD APR 1. 4 2023 Y ARMOU l r OLD KyNG'S HkGHWAY END OF SECTION APPROVED MAY 0 S 2023 YARMOU TH 085604 9� %-{� THERMA-TRU Corp. 1750 Indian. Wood Circle Maumee, OH 43537 Toll Fee 800-891-7400 Phone 419-891-7400 Website www.thermatru.com " F o I -VE 1) APR 14 2023 ?'.AHIVIOW h Product Guide Specification Specifier Notes: This product guide specification is written according to the Construction Specifications Institute (CSI) 3-Part Format, includingMasterFormat, SectionFormat, and PageFormat. The section must be carefully reviewed and edited by the Architect to meet the requirements of the project and local building code. Coordinate this section with other specification sections and the Drawings. Delete all "Specifier Notes" when editing this section. Section numbers and titles are from MasterFormat 2011 Update, DIVISION 08 16 13 FIBERGLASS ENTRY DOORS Specifier Notes: This section covers Therma-Truro branded fiberglass entry door slabs (`Doors') and other components of the doors system which can be sourced through Therma-True. Consult your local Therma-Tru Architectural Sales Specialist for assistance in editing this section for the specific application. PART GENERAL 1.1 SECTION INCLUDES A. Fiberglass Entry Doors B. Impact Resistant Fiberglass Entry Doors C. Fire Rated Fiberglass Entry Doors 1.2 RELATED SECTIONS APPROVED MAY 0 8 2023 YARMOUi h Specifier Notes: Edit the following list of related sections as required for the project. List other sections with work directly related to this section. Verify section numbers and titles. A. 06 40 00 - Architectural Woodwork B. 07 27 00 —Air Barriers: Water-resistant barrier C. 07 92 00 -- Joint Sealants: Sealants and caulking D. 08 80 00 - Glazing E. 08 7100 — Door Hardware F. 09 90 00 - Painting and Coating Fiberglass Entry Doors 08 16 13 RECEIVED APR 1, 4 2023 YAHMOUl h 1.3 REFERENCES A P P Wo-v ED MAY 0 8 20D YARMOUI"h Specifier Notes: Standards listed by reference including reuisions by issuing authority. This article does not require compliance with standards, but is merely a listing of those that may be used. A. American Society for Testing and Materials (ASTM): 1. ASTM E 90 — Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions. 2. ASTM E 283 — Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Difference Across the Specimen. 3. ASTM E 330 — Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference. 4. ASTM E 331— Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference. 5. ASTM E 413 — Classification for Rating Sound Insulation (STC). 6. ASTM E 547 — Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference. 7. ASTM E 1300 — Standard Practice for Determining Load Resistance of Glass in Buildings. 8. ASTM E 1332 — Standard Classification for Determination of Outdoor -Indoor Transmission Class. 9. ASTM E 1886 — Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missiles and Exposed to Cyclic Pressure Differentials. 10. ASTM E 1996 — Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Windborne Debris in Hurricanes. 11. ASTM E 2235 — Standard Test Method for Determination of Decay Rates for Use in Sound Insulation Test Methods. B. California Reference Standard Code: 1. CA SFM 12-7A-1— Materials and Construction Methods for Exterior Wildfire Exposure. C. Canadian Standard: 1. CAN4-S104 — Standard Method for Fire Tests of Door Assemblies. D. Environmental Protection Agency and Department of Energy: 1. Energy Star Program Requirements Product Specification for Residential Windows, Doors, and Skylights. E. Code of Federal Regulations: 1. CFR 1201 Part 2 — Safety Standard for Architectural Glazing Materials. F. Florida High Velocity Hurricane Zone (HVHZ) Testing Application Standards: 1. TAS 201— Impact Test Procedures. 2. TAS 202 — Criteria for Testing Impact and Non -Impact Resistant Building Envelope Components Using Uniform Static Air Pressure. 3. TAS 203 — Criteria for Testing Products Subject to Cyclic Wind Pressure Loading. G. National Accreditation & Management Institute (NAMI) H. National Fenestration Rating Council 1. NFRC 100 — Procedure for Determining Fenestration Product U-Factors. Fiberglass Entry Doors 08 16 13 2• NFRC 200 — Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and Visible Transmittance (VT) at Normal Incidence. 3. NFRC 400 — Procedure for Determining Fenestration Product Air Leakage. I. National Fire Protection Association I,AHMOU'l �'V�� 1. NFPA 252 — Standard Methods of Fire Tests of Door Assemblies i 14 2023 J. Underwriters Laboratory r 1• UL 10B — Standard for Fire Testing Door Assemblies.Ulu'S �f1GHWAY 2. UL 10C — Standard for Positive Pressure Fire Tests of Door Assemblies. 1.4 PERFORMANCE REQUIREMENTS Specifier Notes: Performance ratings for doors vary by product, configuration, and size. Current performance information is found at www.thermatru.com. Consult your local Therma-Tru Architectural Sales Specialist for more information. Delete the following performance requirements if not required. A. Doors shall have a structural design pressure rating of DP [ ], IAPIJF30VED B. Doors shall have an impact design pressure rating of DP [ ` ], MAY 0 8 2023 C. Door Unit Air Leakage, NFRC 400, 1.57 psf (25 mph): 0.50 cfm per square foot of fr YA�'SOH'ITG�HWAY D. Door Unit Water Penetration: No water penetration through door unit when tested in accordance with ASTM E 331or ASTM E 547 with water applied at rate of 5 gallons per hour per square foot at 0 psf. E. Doors shall have a minimum STC rating of [ — ] or a minimum OITC rating of F. Doors shall have a positive pressure certified fire door rating of [ ^ ] minutes. G. Doors shall have a minimum/maximum U-Value of [ ] and a minimum/maximum SHGC of [ _ ) H. Doors shall qualify for Energy Star Rating. 1.5 SUBMITTALS A. Refer to Division 0133 00 Submittal Procedures [Insert division number and title]. B. Product Data: Submit door manufacturer current product literature, including installation instructions. C. Shop Drawings: Submit manufacturer's shop drawings, indicating dimensions, construction, component connections, anchorage methods and locations, accessories, hardware locations, and installation details. D. Samples: Submit full-size or partial full-size verification sample of door illustrating glazing system, quality of construction, texture, and color of finish. Fiberglass Entry Doors 081613 EIVED APP�R1vE D APR 14 2023 MAY 0 8 2023 Y fAhivioU I r, r n ,YARMUU'r h 1,6 QUALITY ASSURANCE A. Mockup: 1. Provide sample unit of representative product size and using Manufacturer approved installation methods to determine acceptability of door installation methods. Comply with Division 0143 39 Quality Assurance 2. Approved mockup shall represent minimum quality required for the Work. 3. Approved mockup shall [not] remain in place within the Work. C. Quality Assurance Submittals: 1. Provide documentation for specified performance as required. 2. Manufacturers' installation instructions. D. Manufacturer Qualifications: Manufacturer shall have successful experience in producing the type of product required for project applications equivalent to the requirements for this project. Specifier notes: Therma-Tru manufactures fiberglass door slabs and related components and sources them to distributor and dealer fabricators for system assembly. Fabricators will have successful experience in producing the type of product required equivalent to the project requirements. E. Installer Qualifications: 1. [Optional: Installer holds current credential as a NAMI Certified Installer of Therma- Tru Side Hinged Door Installations and as a Therma-True Certified Installer.] 1.7 DELIVERY, STORAGE, AND HANDLING A. Refer to Division 0160 00 Product Requirements. B. Delivery: Deliver materials to site undamaged with labels clearly identifying manufacturer, product name, and installation instructions C. Storage: Store materials in an upright position, off ground, under cover, and protected from weather, direct sunlight, and construction activities. D. Handling: protect materials and finish during handling and installation to prevent damage. 1.8 WARRANTY A. Refer to Division 0178 36 Warranties B. Therma-True standard limited warranty for fiberglass Therma-True Door Product and genuine Therma-True components, including rot -resistant frames, mullions, and brickmould sourced from Therma-Tru (excluding primed pine door frames and oak door Fiberglass Entry Doors 081613 0 ;- ft frames, and non -rot resistant mullions and brickmould) used in commercial and multi - residential projects will be free from material and workmanship defects for a period of three years subject to certain limitations and restrictions. For complete details and current warranty information go to www.thermatru.com. PART 2 PRODUCTS 2.1 MANUFACTURER A. Basis of design: Therma-Tru Corp. 1750 Indian Wood Circle Maumee, OH 43537 (419) 891-7400 (800) 843-7628 www.thermatru.com Contact: Rod Clark 458-206-8532 relark@thermatru.com RECEIVED APR 14 2023 ( AMIVIUU I r, APPROVED MAY 0 8 2023 YARMOUTH B. Substitutions: Not permitted C. Requests for substitutions will be considered in accordance with provisions of Division 01 6000. 2.2 A. FIBERGLASS ENTRY DOORS Fiberglass Entry Doors: All fiberglass doors manufactured by Therma-Truo. Specification is for complete entry systems with components manufactured by Therma-Truo and assembled by independent fabricators. 1. Select [Classic -Craft], [Fiber-Classic],v, [Smooth -Star®], [20 Min Fire Door] 2. Construction: a. Classic -Craft 3/32" minimum thickness proprietary fiberglass reinforced thermoset composite, "AccuGrain" textured to duplicate hand-crafted hardwood master or smooth surface. Door edges are machinable kiln -dried hardwood, flush and square with door faces, lock edge reinforced with full-length integrated 3-1/2-inch wide engineered lumber core. Door bottom edge is moisture- and decay -resistant composite. Core is foamed - in -place polyurethane, with a minimum density of 1.9 pcf. b. Fiber -Classic® 1/16-inch minimum thickness, proprietary fiberglass -reinforced thermoset composite, wood -grained in natural hardwood patterns, stainable and paintable. Fiberglass Entry Doors 08 16 13 Door edges are machinable kiln -dried pine, primed, lock edge reinforced with engineered lumber core, lockset area reinforced with solid blocking for hardware backup. Door bottom edge is moisture- and decay -resistant composite. Core is foamed -in -place polyurethane, density 1.9 pcf minimum. Smooth Star ed thermoset Smooth minimum thickness, proprietary fiberglass-reinforc composite, surface lightly textured. Door edges are machinable kiln -dried pine, primed, lock edge reinforced with engineered lumber core, lockset area reinforced with solid blocking for hardware backup. Door bottom edge is moisture- and decay - resistant composite. Care is foamed -in -place polyurethane, density 1.9 pcf minimum. 3. Door Style a. Classic-Crafto 1. American Collection: Enter Style Number [ ]. 2. Mahogany Collection: Enter Style Number [ ]. 3. Rustic Collection: Enter Style Number [ ] 4. Oak Collection: Enter Style Number [ ]. 5. Canvas Collection: Enter Style Number [ ]. b. Fiber -Classic* 1. Mahogany Collection: Enter Style Number [ 2. Oak Collection: Enter Style Number [ ] c. Smooth -Start 1. Enter Style Number [ ] IVD APR I42023 vU i h G KI G'S HtGHWAY APPROVED MAY 0 8 2023 YARMOUTh OLD KING'S HIGHWAY B. Frames: Provided and assembled by third party fabricators to exacting specifications from Therma- Tru to help maximize system performance. Therma-Tru® strongly recommends the use of rot - resistant frames, mullions, and brickmould sourced from Therma-Tru, however, the use of a non Therma-True frame system (or a Therma-Tru Primed Pine Frame or Therma-Tru Oak Frame) will not automatically void the entire limited warranty. Refer to L&B for clarification. 1. Milled from 5/4 kiln -dried material with profiled'/2" stop and 6 degree sill gain prep. 2. Jamb Width [Standard 4 9/16"] Optional: [5 "/"] 16 9/16"] 3. Rot Resistant -- frames, mullions, and brickmould sourced through Therma-Tru. C. Sills 1. Inswing: [Composite Adjustable] [Hardwood Adjustable] [Basic Fixed] [Basic Composite Adjustable] [Moderate Climate] 2. Outswing: [Composite Outswing] [Aluminum with Thermal Break] [Aluminum No Thermal Break] [Coastal] 3. Other:[Public Access Sill] 4. Finish: [Mill] [Bronze] [Brass] [Satin nickel] 2.3 HARDWARE Fiberglass Entry Doors 08 16 13 A. Install fiberglass doors in full compliance with Therma-Tru® written instructions and approved shop drawings. B. Install 20 minute doors with permanent fire door certification label in compliance with the requirements of the labeling agency and NFPA. C. Maintain alignment and compatibility with adjacent work. 3.3 FINISHING A. Finish in compliance with Therma-Tru® written recommendations. Guidance for proper finishing is available at www.thermatru.com — "Recommendations for Proper Finishing and Painting or Staining." 3.3 Protection A. Protect installed products until completion of project. B. Touch-up, repair or replace damaged products prior to Substantial Completion in accordance with Therma-Tru written recommendations. Guidance for proper finishing is available at www.thermatru.com — `Recommendations for Proper Finishing and Painting or Staining." APR 14 201" 4 c ►+r+ -S H1G MY O1D K! END OF SECTION Fiberglass Entry Doors 081613 APPROVED MAY 0 8 2023 YARMOUTh V In 1/ If , �..-.. ;-��- /1*-�