Loading...
HomeMy WebLinkAboutEngineer PlanI I FFE = 15.5 1 SEWAGE SYSTEM PROFILE & DETAILS DWELLING NOT TO SCALE PROPOSED 4" PVC OUTLET 10' MIN. DISTANCE "T" AND SEWER PIPE. FROM FOUNDATION SCHEDULE FG 12.4t PROPOSED D BOX WITH 40 PVC PIPE (TIGHT JOINTS) ACCESS MANHOLE COVER WITHIN 6" OF FINISHED GRADE. ?..� FG 12.5t Inv. elev.= 10.30 • �:;'' Inv. elev.= 10.05 ••4 y L=20' - 4" PVC ,. SCHD. 40 PIPE @ s=0.02 MIN. -i L=29' •- 4" PVC SCHD. 40 PIPE @ s=0.01 ' I z SCH. 40 PVC TEES M IW-i � 50 in LU>- d ( GAS BAFFLE �I Inv. elev.= 9.76 W W w WWW m wmV O Z ZOz Bottom el.= 5.72 PROPOSED SEPTIC TANK 1,500 GALLON, H-10 LOADING \_6" MIN. CRUSHED STONE BASE- * EXISTING BUILDING SEWER NOTES 1 - BUILDING SEWER PIPE INVERT ELEVATION TO BE CONFIRMED PRIOR TO CONSTRUCTION. 2 - CONTRACTOR SHALL INTERCEPT EXISTING BUILDING SEWER WITH NEW 1,500 GALLON SEPTIC TANK AND INSTALL 4" PVC 'T's IN CONFORMANCE WITH TITLE 5. SEPTIC SYSTEM NOTES 1. ALL CONSTRUCTION AND MATERIALS SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE, TITLE 5 (310 CMR 15.00), AND THE LOCAL BOARD OF HEALTH. 2. THERE SHALL BE NO CHANGES MADE IN THIS PLAN WITHOUT THE WRITTEN PERMISSION OF THE ENGINEER AND LOCAL BOARD OF HEALTH. 3. ALL ERRORS, OMISSIONS, AND CHANGE OF CONDITIONS AT THE SITE SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO PERFORMING THE RELATED WORK. 4. ALL DISTURBED AREAS ARE TO BE LOAMED, SEEDED AND MAINTAINED TO PREVENT EROSION. 5. FOR PROPER PERFORMANCE, SEPTIC TANK SHOULD BE INSPECTED AT LEAST ONCE A YEAR AND WHEN THE TOTAL DEPTH OF SCUM AND SOLIDS EXCEEDS 1/3 THE LIQUID DEPTH OF THE TANK, THE TANK SHOULD BE PUMPED. 6. THIS SYSTEM HAS BEEN DESIGNED FROM DATA REVIEWED AND ACKNOWLEDGED BY THE MASS. D.E.P. AND THE LOCAL BOARD OF HEALTH; AND CONFORMS WITH THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE 5. NO GUARANTEE OF PERFORMANCE IS EXPRESSED OR IMPLIED. 7. TEST HOLE INFORMATION SHOWN HEREON IS LIMITED TO SOIL CONDITIONS FOUND AT THAT PARTICULAR TEST HOLE LOCATIONS AND IS NOT CONSIDERED AN IMPLIED OR EXPRESSED WARRANTY OF SOIL CONDITIONS BEYOND LIMITS OF SUCH TEST HOLES. 8. ALL ORGANIC AND UNSUITABLE MATERIAL MUST BE REMOVED FROM THE AREA DIRECTLY UNDER AND 5 FEET BEYOND THE PROPOSED LEACHING FACILITY. THIS AREA MUST BE BACKFILLED TO THE ELEVATIONS INDICATED ON THESE PLANS WITH SELECT ON -SITE OR IMPORTED SOIL MATERIAL, CONSISTING OF CLEAN GRANULAR SAND OR OTHER GRANULAR MATERIAL, FREE FROM ORGANIC MATTER AND OTHER DELETERIOUS SUBSTANCES. MIXTURES AND LAYERS SHALL NOT BE USED. THE FILL MATERIAL SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE, TITLE 5 - 310 CMR SECTION 15.255 (3) AND SHALL HAVE PERCOLATION RATE OF BETWEEN TWO AND FIVE MINUTES PER INCH, BEFORE AND AFTER PLACEMENT. 9. ALL STONE MUST BE DOUBLE WASHED AND FREE FROM FINES AND ANY ORGANIC MATERIAL AND MUST HAVE LESS THAN 0.2 PERCENT MATERIAL FINER THAN A NUMBER 200 SIEVE. 10. THE DESIGNER HAS NOT BEEN RETAINED BY THE CLIENT TO CONSTRUCT OR SUPERVISE THE CONSTRUCTION OF THE SYSTEM. THE CONTRACTOR IS RESPONSIBLE FOR MAKING ARRANGEMENTS FOR INSPECTION OF INSTALLATION OF THE SYSTEM WITH THE LOCAL BOARD OF HEALTH. 11. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL HORIZONTAL AND VERTICAL CONTROL OF ALL SYSTEM COMPONENTS. 12. TIGHT JOINT PIPING MATERIAL TO CONSIST OF POLYVINYL CHLORIDE (P.V.C.) SCHEDULE 40, UNLESS OTHERWISE NOTED. 13. THE CONTRACTOR SHALL NOTIFY THE DESIGN ENGINEER FOR CONSTRUCTION INSPECTION AFTER EXCAVATION FOR THE LEACHING BED (PRIOR TO THE PLACEMENT OF STONE) AND ALSO AFTER PLACEMENT OF PIPE & STONE PRIOR TO BACKFILLING. 14. DESIGN ENGINEER SHALL CERTIFY CONSTRUCTION OF SYSTEM AND MATERIALS INSTALLED. THE CONTRACTOR SHALL PROVIDE A SIEVE ANALYSIS OF THE FILL MATERIAL REQUIRED. AN AS -BUILT PLAN SHALL BE SUBMITTED TO THE LOCAL BOARD OF HEALTH UPON COMPLETION. 15. NO RUBBER TIRE CONSTRUCTION MACHINERY SHALL DRIVE OVER THE PROPOSED SEPTIC BED EXCAVATION DURING CONSTRUCTION. 16. DIG -SAFE AND ALL OTHER NECESSARY AUTHORITIES SHALL BE NOTIFIED FOR THE PROPER LOCATION OF EXISTING UTILITIES PRIOR TO ANY EXCAVATION. 17. WATER SERVICE LINE SHALL BE LOCATED AND MARKED PRIOR TO ANY EXCAVATING AND 10' MIN. SETBACK DISTANCE FROM SAID SERVICE TO THE SEPTIC SYSTEM SHALL BE MAINTAINED. 18. ALL WATER LINES WITHIN 10' OF SEPTIC SYSTEM COMPONENTS SHALL BE SLEEVED WITHIN 4" PVC SCHEDULE 40 PIPE, 11.9 NOTES: 1. FURNISH RISERS TO SET COVERS WITHIN 6 INCHES OF FINISH GRADE. 2. H-10 SEPTIC TANK AND CHAMBERS AND H-20 DISTRIBUTION BOX (D-BOX), AND SCHEDULE 40 PVC PIPE THROUGHOUT. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A TRENCH PERMIT FROM THE LOCAL MUNICIPALITY IN WHICH THE WORK IS BEING PERFORMED. S=2% MINIMUM H-20 D-BOX 1 WITH SPEED ` FIRST 2' SHALL LEVELERS BE SET LEVEL 1 =6' @ S=0.028 I Inv. elev.= 9.59 1 I Inv. elev.= 9.42 1 BACK FILL WITH 9" MIN. 36" MAX. CLEAN MATERIAL SEE STRIPOUT NOTE EL.=9.84 TOP OF INFILTRAT( _4, 4' J oft" to 1�' washed stone all around infiltrator STRIPOUT NOTE: THE CONTRACTOR SHALL EXCAVATE 5 FT. ALL AROUND THE LEACHING FACILITY AND DOWN TO THE MEDIUM SAND (ELEV. 9.0t), REMOVE AND DISPOSE ALL UNSUITABLE MATERIAL AND REPLACE WITH CLEAN GRANULAR SAND CONFORMING WITH THE SPECIFICATIONS SET FORTH IN 310 CMR 15.255 (3). 6'-3" TYPICAL HIGH CAPACITY INFILTRATOR SCALE: N.T.S (H-20 LOADING) 10'- 6" F_ 20" Diameter Access Holes w J t- INLET \ / O o0 1 ` � STEEL REINFORCED PRECAST CONCRETE PLAN VIEW 3" REMOVABLE COVERS 3" �! in ,, 5 - 5" OUTLET KNOCKOUTS OUTLET ALL ACCESS MANHOLE COVERS FOR SEPTIC TANK, DISTRIBUTION BOX, AND LEACHING STRUCTURE SET MORE THAN 6" BELOW FINISHED GRADE, SHALL BE RAISED TO WITHIN 6" OF FINISHED GRADE. FRAME & COVER OVER 'TS" I FG 1 11.8t 1 2" LAYER OF J" TO #' WASHED STONE OR FILTER FABRIC Elev.= 8.50 4' OF NATURALLY OCCURRING PERVIOUS MATERIAL Bottom of Test Hole Elev.= 3.5 Observed GWT Elev.= 3.1 (57 LEWIS BAY ROAD) END CAP AT BEGINNING & END OF EACH ROW INSTALL POLYLOK FLOW EQUALIZERS ON ALL OUTLET PIPES i- CONCRETE COVER CROSS-SECTION ALL OUTLET PIPES FROM THE PRECAST DISTRIBUTION BOX SHALL BE CONCRETE SET LEVEL FOR AT LEAST 2 FT. TANK RISER 8„ 2" in. clearance required s L 121 INLET'T' 2" min. inlet to outlet _ 6"min. OUTLET L 10"min. 14"min. Liquid level 5'-7" 5'-0" 4'-0" min. 4'-0" min. Liquid depth TUF-TITE Liquid depth GAS BAFFLE j 3" 10'-01, �5'-2"--�� CROSS-SECTION END -SECTION TYPICAL 1,500 GALLON SEPTIC TANK NOT TO SCALE (H-10 LOADING) 24" PLAN SECTION 5 HOLE DISTRIBUTION BOX NOT TO SCALE (H-20 LOADING) PROPOSED 1/2" REBAR TO LOCATE IN FUTURE. 16" -t RECINVOID MAY 0 2 2023 HEALTH ®EPT. 4" CLEANOUT CAP WITHIN 3" OF FINISHED GRADE 3" MAX. 4" SOLID PVC PIPE 12" MIN. 36" MAX. -FASTENERS -STANDARD E INFILTRATOR TYPICAL OBSERVATION PORT NOT TO SCALE SOIL EVALUATOR'S LOG Depth from surface in inches Soil Horizon Soil Texture (USDA) Soil Color (Munsell) Soil Mottles and Depth Other Relative Factors DEEP OBSERVATION HOLE TP#1, ELEVATION 13.5 0 - 8" A SANDY LOAM 10 YR 313 8" - 54" B SANDY LOAM 10 YR 5/6 54" - 120" C MEDIUM SAND 2.5 Y 5/4 NO SINGLE GRAIN PERCOLATION RATE = < 2 MINUTES / INCH IN C LAYERS �c DEPTH TO GROUNDWATER = NONE ENCOUNTERED AT 120" (ELEV. =3.5) OBSERVATIONS BY: LARRY CARREIRO WITNESSED BY: PHIL PENAUD DATE TESTED: MARCH 16, 2022 �c OBSERVED GROUNDWATER ELEV. =3.1 FT. �NOF NAVD88 FROM PERC. TEST @ #57 LEWIS BAY ROAD DATED MARCH 18, 2015. �o� N. DOUGLAS SCHNEIDER CIVIL No. 38540 NOTICE THIS PLAN MAY NOT BE ADDED TO, DELETED FROM, OR ALTERED IN ANY WAY BY ANYONE OTHER THAN HOLMES AND MCGRATH. UNLESS AND UNTIL SUCH TIME AS AN ORIGINAL (RED) STAMP APPEARS ON THIS PLAN NO PERSON OR PERSONS, MUNICIPAL OR PUBLIC OFFICIAL MAY RELY UPON THE INFORMATION CONTAINED HEREIN, AND THIS PLAN REMAINS THE PROPERTY OF HOLMES AND MCGRATH. COPYRIGHT (C) BY HOLMES & MCGRATH. ALL RIGHTS RESERVED LOT COVERAGE NOTES EXISTING PROPOSED MAXIMUM ALLOWABLE BY STRUCTURES 14.8% 15.6% 25% LEGEND BOUND WITH DRILL HOLE FND • EDGE OF CLEARING EXISTING GRADE -- EXISTING SPOT GRADE 10.9 EXISTING DECIDUOUS TREE EXISTING CONIFER TREE CB w/DH FOUND APPROXIMATE LOCATION OF EXISTING WATER SERVICE ;�L­U j ELEC. BOX APPROXIMATE LOCATION OF P���1 SERVIICE NG GAS J " O Rsr. X 12.6 " 14X2 ,S �9\ S 7 12.8 X ' PROPOSED NEW METER \ N/F JAMES H. & \ PORCH 5.0'x36.1' � DEBORAH M. CAOLA 14X4" \ � �Q �� GAS p� X 13.4 TIP\ �G METER F QQO ?� AC yOF 9 PAD ++ \ EXISTING SEPTIC TANK & D-BOX ,p 13.5 x 05►1\ Q TO BE PUMPED DRY, REMOVED 6 X 12.1 \ �GFp OVERHANG Q�OQ G G AND DISPOSED OF OFF SITE. EXISTING LEACHING PITS TO BE PUMPED DRY, CRUSHED & FILLED WITH CLEAN PROPOSED NEW "�h� , �� BULKHEAD 1\ f\ SAND AND ABANDONED OR REMOVE AS ENTRY PORCH �� REQUIRED FOR CONSTRUCTION, C'A \LOCATION PER TOWN RECORDS. 5.3'x13.9' 0 1 1 O O x 12. y PROPOSED �e '�� i QQ-OJ�Q'O ' LFC COBBLE APRON JV ro / �`•:' ~ ";1` 8 3- FRANK E/& MARY s�sr. �6'j G� ���` w. ELLEN ZAPPUILLA � 'c' 57r, 0 12.9 \l `���.8 0 ��� � 11.9 x \`9" AC /: 8, 1.1ol INSPECTION CB w/DH 0 ✓ FIRE PIT 0 I'J�J PORT TYP. OF 2 PAD TO BE f 0 6�. �o j ( ) FOUND RELOCATED I o 1 LOT ..L_7Z ' 16,597t S.F. PROPOSED NEW RINSE STATION ENCLOSURE o RICHARD & PROPOSED 2' DIA. DRYWELL * x12.2 �O j \ \ 5 �, 5°` ELISABETH BOUWMAN WITH 2' OF STONE ALL AROUND ", \ 12.0 x FOR RINSE STATION: 1,500 GALLON SEPTIC \`��- \ G CB w/DH TANK (H-10) INSPECTION OUND PORT PROPOSED SEPTIC SYSTEM (8) HIGH CAPACITY INFILTRATORS (H-20) WITH 4' OF DOUBLE WASHED CRUSHED STONE p,� t`L' ALL AROUND. 10.83'W x 61.00'Lx16"D ++c�,�, x 12.0 O% DAVIDN&FMARY (SEE DETAILS SHEET 2) OF D� V NOTES 1. HOUSE NUMBER: 162 SPRINGER LANE 2. ASSESSOR'S NUMBER: 23-346 3. ZONING DISTRICT: R-25 4. FLOOD HAZARD ZONES: X (500 YEAR) 5. BENCHMARK: AS SHOWN 6. TOPOGRAPHIC INFORMATION BASED ON AN ON THE GROUND INSTRUMENT SURVEY. 7. ELEVATIONS SHOWN ARE BASED ON THE NORTH AMERICAN VERTICAL DATUM 1988 8. REFERENCE: PLAN BOOK 120 PAGE 89 PLAN BOOK 36 PAGE 131 DEED BOOK 25423 PAGE 151 9. WIND EXPOSURE CATEGORY: B 10. LOT IS LOCATED IN A WIND BORNE DEBRIS REGION STAKE G' ELLEN BOTTING w/TACK CB w/DH SET .----,FOUND GRAPHIC SCALE 20 10 0 20 ( IN FEET ) 1 inch = 20 ft. rill DETAIL� � -�� Yar1r:011tla Ueai h Department M V�s Ef_ N. DOUGLAS SCHNEIDER No.47383 N.DOUGLAS SCHNEIDER CIVIL No. 38540 MEN MA 17-11 LOCUS MAP NOT TO SCALE DESIGN DATA 1. TYPE OF ESTABLISHMENT: 5-BEDROOM SINGLE FAMILY RESIDENCE 2. SEWAGE SYSTEM DESIGN FLOW: 110 GALLONS PER BEDROOM = 110 x 5 = 550 GPD 3. NOTE: THIS SEPTIC SYSTEM IS NOT DESIGNED FOR A GARBAGE GRINDER 4. SEPTIC TANK CAPACITY REQUIRED, MINIMUM OF 200% OF DESIGN FLOW OR 1,500 GAL. = 200% x 550 GALLON = 1,100 GALLON (USE 1,500 GALLON TANK) 5. DESIGN PERCOLATION RATE: ASSIGNED LESS THAN 5 MINUTES PER INCH 6. SOIL ABSORPTION SYSTEM TYPE: CHAMBER SYSTEM 7. LEACHING AREA REQUIRED: MINIMUM 550 GPD / (0.74 GPD/S.F., CLASS I SOIL) _ 743 S.F. 8. LEACHING SYSTEM PROPOSED: 61.0' LONG x 10.83' WIDE x 11" HIGH SYSTEM BOTTOM AREA PROPOSED = 10.83' x 61.0' = 660.6 S.F. SIDE AREA PROPOSED = 2 x (10.83' + 61.0') x I I" = 131.7 S.F. TOTAL AREA PROPOSED = = 792.3 S.F. 9. LEACHING SYSTEM CAPACITY PROPOSED = 792.3 S.F. x 0.74 GPD/S.F. = 586.3 GPD NOTICE THIS PLAN MAY NOT BE ADDED TO, DELETED FROM, OR ALTERED IN ANY WAY BY ANYONE OTHER THAN HOLMES AND MCGRATH. UNLESS AND UNTIL SUCH TIME AS AN ORIGINAL (RED) STAMP APPEARS ON THIS PLAN NO PERSON OR PERSONS, MUNICIPAL OR PUBLIC OFFICIAL MAY RELY UPON THE INFORMATION CONTAINED HEREIN; AND THIS PLAN REMAINS THE PROPERTY OF HOLMES AND MCGRATH. COPYRIGHT (C) BY HOLMES & MCGRATH. ALL RIGHTS RESERVED DATE DESCRIPTION lDrawnIChecked R E V I S 1 0 N S PLAN OF PROPOSED SEWAGE DISPOSAL SYSTEM PREPARED FOR THE MORRISON FAMILY TRUST LOT 44, #162 SPRINGER LANE IN WEST YARMOUTH, MA SCALE: 1 "=20' DATE: JUNE 13, 2022 holmes and mcgrath civil engineers and land surveyors 205 worcester court • suite a4 •falmouth, ma • 02540 508-548-3564 www.holmesandmcgrath.com DRAWN: JJF, LAC CHECKED: JOB NO: 221274 DWG. NO.: 89-4-82 SHEET 1 OF 2