Loading...
HomeMy WebLinkAboutSite PlanPram Ave \_ L�rl \ d- ''` SITE PLAN N e SIT x 58' \ ` SCALE: 1 " = 20' s C.B. Fnd \. B.M.-50.00,(ASSUMED) m 2 $ Yachtve v o y A 00 \ ON C.B. FND. S17ver"Of Lone \ ''• ` TOWN OF YARMOUTH F "Yarmouth" 0,�, 30-213 LOCUS \�s0 vacant NO SCALE DECK 45'..37' X 42.22' O lam. F, \ LOT ".15 o� GARAGE AREA=12,543t S.F. 1 CONCRETE 43.49' • " :.PATIO`: ":; f • �. .B. Fn - concrete retalnln9 �p .PAVED �. _ EXISTING DWELLING B . M . DRIVEWAY-"_: > •..`:•" 'flowery generator X .7 MCP .6 bed' 45.64' 4 .38 8.03' •;�/r - gas meter l `t�p �� >.." •, •^ h, ,`c Mp ox. location. / [P` \..�.flower , 908 0 'bed, ` . " 9P a 47.78' 48. fl el LEGEND —G— Approximate location 45.05 gas line .. ( PROPOSED SAS �s' 30'x15 x0.5 leach field with 4" SCH —W— Approximate location l '` r water line \ 40 PVC laterals 4 on center. ..........18........ Existing contour �h 44.43' It �� Approximate Location of Existing Cesspools catch basin (to be pumped and removed) 101.70' X Denotes existing spot grade Test Hole O O Proposed 1,500/500 gallon S.T./P.C. GENERAL NOTES 1. ADDRESS: 14 CUTTER LANE, YARMOUTH, MA. 2. ASSESSOR'S NUMBER: MAP 22 PARCEL 129 3. DEVELOPER'S LOT: LOT #15 4. TOPOGRAPHIC INFORMATION WAS COMPILED FROM AN ON THE GROUND INSTRUMENT SURVEY. 5. TOWN WATER IS PROVIDED TO THE SITE & SURROUNDING PROPERTIES. 6. WETLANDS ARE SHOWN PER SWEETSER REFERENCE PLAN. 7. REFERENCE PLAN: PLAN BOOK 173 PAGE 3. REFERENCE PLAN: "CERTIFIED PLOT PLAN OF LAND IN WEST YARMOUTH, MASSACHUSETTS AS PREPARED FOR RACHEL L. MINGOS," DATED MAY 21, 2021, SCALE: 1'=40', BY PAUL E. SWEETSER, PLS, DENNISPORT, MA. 8. UTILITIES LOCATED BY DIGSAFE. 9. THIS DESIGN PLAN IS TO BE UTILIZED FOR THIS SEPTIC REPAIR ONLY. 10. EXISTING SEPTIC COMPONENTS WERE LOCATED IN THE FIELD. 11. THE PROPERTY IS NOT LOCATED IN AN AREA OF CRITICAL ENVIRONMENTAL CONCERN. 12. THE PROPERTY IS NOT LOCATED IN A NATURAL HERITAGE AND ENDANGERED SPECIES PROGRAM AREA. 13. THE PROPERTY IS LOCATED IN A ZONE—X MINIMAL FLOOD HAZARD ZONE. 14. THE PROPERTY IS NOT LOCATED IN A DEP ZONE II. PROPOSED SEPTIC SYSTEM REPAIR PREPARED FOR RACHEL MINGOS AT #14 CUTTER LANE YARMOUTH, MA ALL OUTLET PIPES FROM THE DISTRIBUTION BOX SHALL BE 12• SET LEWL FOR AT LEAST 2 FT. CONCRETE COVER •�•. 3 — 5' OUTLET 3' KNOCKOUTS 18• OUTLET •� ( I 12• MET s ,• 3 18• 3, PLAN —SECTION CROSS SECTION 3 HOLE H-20 DISTRIBUTION BOX NOT TO SCALE Desian Calculations Number of Bedrooms: 3 Equivalent to 330 Gal./Day Garbage Disposal: Not allowed with this design Septic Tank Capacity Required: 330 gpd x 200% = 660 gpd. Septic Tank Capacity Provided: Proposed 1,500—gal H-10 septic Tank Leaching Capacity Required: 330 gpd x LTAR= 446 SF Req'd Area LTAR for Class I soil at <2 min./inch = 0.74 gal/sq. ft. Proposed Leaching Structure: 1-30'x15'x0.5' Leaching Field Bottom Leaching Area Provided = 450 Sq.Ft. Sidewall Leaching Area Provided = 0 sq. ft. Total Leaching Area Provided = 450 sq. ft. > 446 sq. ft req'd. Leaching Capacity Provided =450 sq. ft X 0.74 gal/sq.ft.=333 gpd. PREPARED BY: A Perfect Environment LLC dba Geo—Cape Environmental Consultants 100 Independence Drive, Suite 7-623 Hyannis, MA 02601 Tel: 774-238-1813 Email: aperfectenvironmentOgmail.com SCALE: 1 "=20' DRAWN BY: TWH DATE: 5 MAY 2023 DATUM: ASSUMED FILENAME:I4CUTTER SHEET 1 OF 3 *NOTE: ALL PIPES ARE TO BE 4" SCHEDULE 40 P.V.C. SYSTEM PROFILE Not to Scale Existing Dwelling First Floor=50.93' Top of Fndn.= 4' CELLAR ' WALL ' Bsmt. FI.=43.2' `. Ex. Invert Elev.=4 Septic tank cover must be within 6" of finished grade Manhole covers must be secured at finished grade =46't • � Tlss�� Existing invert elevations shall - - - -- - --- - - f- be verified . • • PROPOSED 1,500/500 GAL. H-10 SEPTIC TANK/PUMP CHAMBER (SEE TANK DETAIL FOR TYPE & DIMENSIONS) 20" DIAMETER SECURED COVER TO FINISHED GRADE t_11, FINISHED GRADE ELEV.-46't LIFT OUT CHAIN ---..- INLET INVERT ELEV = 42.95' 32' OR 330 GALS. reserve storage E 48" a : ,- 6" of 3/4" - 11/2" Stone PUMP DETAI Not to Scale S ,= 0.01' 5' 3 HOLE H-20 DIST. BOX D-Box cover shall be within 6" of finished grade Provide 2" SCH 40 PVC tee on inlet LEVEL irc rt rt x i =44.87' p --44.70 6" OF 3/4"-11 /2" STONE Provide 4" dia. observation port to within 3" of grade Finished grade\over system=2% slope away L=30' - - 4" Perforated P.V.C. Washed 5' STRIPOUT 3/4"-1 1/2" Crushed, Double -Washed Stone LEACH FIELD 2' -Min. 2" of.1/8"-1/2" Washed Stone or non -woven filter fabricl MIN. (6.2't provided) 'ADJUSTED GW ELEV.=37.82' IF31l�lE�IF IE�IBIE�IE91E9IBIE3IE PUMP 1. NOTES & SPECIFICATIONS PROVIDE 1 LIBERTY MODEL LE 41A 4/10 hp, 115 VOLT, SINGLE PHASE SUBMERSIBLE PUMP CAPABLE OF DISCHARGE ouTLEr INVERT ELEV-42.95' CAPACITY OF 80 GPM AT 13.6 FEET TDH, OR EQUAL. PUMP SHALL BE CAPABLE OF PASSING A MINIMUM SOLID SIZE OF 2" DIAMETER OR EQUAL. 3/8" WEEP HOLE ABOVE CHECK VALVE 2. USE LIBERTY SIMPLEX ELECTRIC (FREEZE PROTECTION) CONTROL PANEL OUTDOOR MOUNTED W/VISIBLE 2" SWING CHECK VALVE-P.V.C. ALARM OR EQUAL 3. PUMP SHALL BE INSTALLED IN STRICT COMPLIANCE HIGH WATER ALARM ELEV-40.29' WITH MANUFACTURER'S SPECIFICATIONS. _ PUMP ON ELEV.=40.12' 4. ALARM SHALL CONSIST OF AUDIBLE SIGNAL & RED WARNING LIGHT TO BE INSTALLED IN BUILDING PUMP OFF ELEV.-39.45' AND POWERED BY SEPARATE CIRCUIT FROM CIRCUITS TO PUMP. 5. DOSE VOLUME=4 DOSES PER DAY= 330 GAL/4 DOSES=82.5 GAL./DOSE 6. ELECTRICAL PERMIT REQUIRED FOR ALARM & POWER TO PUMP. 7. ALL OUTDOOR CONNECTIONS TO BE SEALED WITHIN NEMA 4 ENCLOSURES. 8. THE FORCE MAIN SHALL BE 2' DIA. SCH 40 PVC FLOOR PUMP CHAMBER ELEV.=36.95' WITH THRUST BLOCKS INSTALLED, AS NECESSARY. 9. INSTALL STAINLESS STEEL SLIDE RAIL SYSTEM AND SIMPLEX DISCHARGE PIPING OR PULL CHAIN OR EQUAL. CONSTRUCTION NOTES 1. Contractor is responsible for Digsafe notification and protection of all underground utilities, site features and pipes. 2. The septictank and distribution box shall be set level on 6„of 3/4"-11/2" stone. 3. Backfill should be clean sand or gravel with no stones over 3" in size. 4. This system is subject to inspection during installation by Geo-Cape Environmental Consultants. 5. The contractor shall install this system in accordance with Title 5 of the Massachusetts Environmental Code and local Board of Health Rules and Regulations. 6. If, during installation the contractor encounters any soil conditions or site conditions that are different from those shown on the soil log or in the design, the installer shall halt installation and immediately notify Geo-Cape Environmental Consultants. 7. No vehicle or heavy machinery shall drive over the septic system unless noted as H-20 septic components. 8. All piping shall be 4" diameter SCH 40 PVC unless otherwise specified. 9. No wells are located within 150' of proposed SAS. 0. Provide 1 1,500/500-gal H-10 Septic Tank/Pump Chamber and 1 DB-3 H-20 D-Box by Wiggin Precast or equal. 1. Existing cesspools shall be pumped and removed. 2. The designer is not responsible for undocumented septic components. 13. The septic components shall be marked with magnetic marking tape. 14. The Contractor shall provide a minimum of 24 hour notice to the Designer and Board of Health for as -built inspection of the system prior to backfilling. 15. Install Zabel A1800 effluent tee filter or equal on septic tank outlet tee end. The effluent tee filter shall be serviced annually and at manufacturer's specs. 16. Provide one 4" SCH 40 PVC observation port to the bottom of SAS with the top 3" from grade. Provide a screw cap and metal object for easy 17. A five-foot horizontal stripout Of Soil shall be performed around the SAS and vertically to the C1 layer and replaced with fill meeting specifications of 310 CMR 15.255(3). _:_&&A.. PROPOSED SEPTIC SYSTEM REPAIR PREPARED FOR RACHEL MINGOS AT #14 CUTTER LANE YARMOUTH, MA PERK TEST & SOIL EVALUATION DATE OF TEST HOLE: APRIL 26, 2023 Performed By: GLEN E. HARRINGTON, R.S. Witness: JAY GARDINER, HEALTH AGENT Excavator: SHAWNS' TREE SERVICE Percolation Rate: < 2 MPI IN C1 Test Hole No. 1 DEPTH SOILS ELEV. 45.92 FI LL 41.09 Ab LOAMY SAND " 10YR5 2 40.59 Bw LOAMY SAND 86" 10YR5 6 38.76 C1 MEDIUM - COARSE 98„ SAND 37.8 120" 122" 2.5Y6 41 35.75 Frimoter Calculation Reference Well: Mashpee MIW-29 Range: Zone B Current Well Data: APRIL 2023 Water Level: 7.62' Adjustment: 1.9' Therefore adjusted depth to groundwater= 98" or Elevation=37.82' ADJ. G.W. OBS. c.w. Soil Evaluation Certification I certify that on October, 1995, 1 hove passed the soil evaluator examination approved by the DEP and that the analysis was performed by me consistent with the required training, expertise and experience described in 310 CMR 15.017. GLEN E. HAFANGTON. R.S. locating. IS PREPARED BY: A Perfect Environment LLC c dba Geo-Cape Environmental Consultants 100 Independence Drive, Suite 7-623 Hyannis, MA 02601 Q Tel: 774-238-1813 Mt� Email: operfectenvironment®gmail.com SCALE: 1"=20' DRAWN BY: TWH DATE- 5 MAY 2023 DATUM: ASSUMED FILENAME: 14CUTTER SHEET 2 OF 3 4-20" DIAM. ACCESS MANHOLES (typ.) INLET INLET 6' STEEL REINFORCED PRECAST CONCRETE PLAN VIEW /-4-20" REMOVABLE COVERS (typ.}-� // y \ ' I' 3' In. clearance'"'. 8' min. min. Inlet to outlet 8' mM INLET i -1-2' T--- T Uquid level —� t0' min. „ r -4- fS `. 6,-4 E o } •• 4'-0' min. . o� Infee'tal Zabel A180p Neffluent �' Liquid dept .• I fitter or equal a o' J 2' g^ T — 1 2'-0' — OUTLET THE ACCESS COVER FOR THE SEPTIC TANK INLET MANHOLE AND DISTRIBUTION BOX SHALL BE WITHIN 6" OF GRADE. THE ACCESS MANHOLES OVER THE EFFLUENT TEE FILTER & PUMP SHALL BE SECURED AT FINISHED GRADE. - OUTLET INVERT 6' -4" 4'-O" min. Liquid depth 6'-0' 6' —6. — CROSS—SECTION END —SECTION TYPICAL 1500/500 GALLON H-10 SEPTIC TANK/P.C. NOT TO SCALE LEACH FIELD PLAN VIEW NOT TO SCALE 2" 1/8"-1/2" Double —Washed Stone or non —woven geo— textile filter fabric 3'-6" 4'-0" on center ( 4'-0" on center I 3'-6" _ LEACH FIELD CROSS-SECTION NOT TO SCALE SAS LAYOUT Scale: 1 "=20' CORNERBOARDS TO CORNER COMPONENTS A-1 = 14'-2" B-1 = 19'-3" A-2 = 24'-2" B-2 = 10'-11" A-3 = 25'-10" B-3 = 48'-8" A-4 = 24'-0" B-4 = 26'-8" PROPOSED SEPTIC SYSTEM REPAIR PREPARED BY: A Perfect Environment LLC PREPARED FOR dba Geo—Cape Environmental Consultants RACHEL MINGOS 100 Independence Drive, Suite 7-623 AT }"gyp Q Hyannis, MA 02601 # 14 CUTTER LANE T ¢r4� el: 774-238-1813 Email: harr88®hotmail.com 1fT . �N,TA��Q' SCALE: 1"=20' DRAWN BY: GEHRS DATE: 5 MAY 2023 YARMOUTH, MA DATUM: ASSUMED FILENAME:14Cutter SHEET 3 OF 3