Loading...
HomeMy WebLinkAboutBLDE-21-006656 Commonwealth of Official Use Only _ Massachusetts Permit No. BLDE-21-006656 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:5/18/2021 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to pertorm the electrical work described below. Location(Street&Number) 41 POWERS LN Owner or Tenant SKWAR DONALD R Telephone No. Owner's Address SKWAR MARY JULIA, 33 BRADFORD WALK, FARMINGTON, CT 06032 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(15 panels 4.43 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Total No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool grade ❑ Ign-nd. ❑ No.of Emergency Lighting r Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Gas Burners No.of Detection and No.of Switches Initiating Devices No.of Air Cond. Total No.of Alerting Devices No.of Ranges Tons Heat Pump Number Tons KW No.of Self-Contained No.of Waste Disposers Totals: Detection/Alerting Devices Municipal ❑ Other: No.of Dishwashers Space/Area Heating KW Local ❑ Connection HeatingAppliances KW Security Systems:* No.of Dryers PP No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Siens Ballasts No.of Devices or Equivalent Telecommunications Wiring: No.Hydromassage Bathtubs No.of Motors Total HP No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Aliaksei A Kuharenka LIC.NO.: 20711 Licensee: Aliaksei A Kuharenka Signature Bus.Tel.No.: (If applicable,enter"exempt"in the license number line.) Alt.Tel.N Address:564 W YARMOUTH RD,WEST YARMOUTH MA 026731456 *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. I Owner/Agent I PERMIT FEE: $150.00 Signature Telephone No. Q oL (No /�t + 5 " ) Ly0 73.Art-632L Commonwealth o////aaaachuoeila Official Use Onl r _-* _ t c� Permit No. V� Y— 7 c 1_ .2)epariment o� ire 3ervicea Occupancy and Fee Checked t BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 5-17-21 City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number)41 Powers Ln Owner or Tenant Prokop Telephone No. Owner's Address Same Is this permit in conjunction with a building permit? Yes ® No ❑ (Check Appropriate Box) Purpose of Building Residence Utility Authorization No. Existing Service Amps / Volts Overhead❑ Undgrd❑ No.of Meters New Service Amps / Volts Overhead n Undgrd n No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Woi k: Wire 15 panel solar PV system. System size:4.43 kW AC Wire(3)Tesla Powerwall 2 energy storage system Completion of the following_table may be waived by the Inspector of Wires. No.of Total No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA Above In- No.of Emergency Lighting No.of Luminaires Swimming Pool grnd. ❑ grnd. ❑ Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Detection and No.of Switches No.of Gas Burners Initiating Devices Total No.of Ranges No.of Air Cond. Tons No.of Alerting Devices No.of Waste Disposers Heat Pump Totals: Number Tons KW No.of Self-Contained Detection/Alerting Devices Municipal No.of Dishwashers Space/Area Heating KW Local❑ Connection ❑ Other Heating Appliances KW Security Systems:* No.of Dryers No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent Telecommunications Wiring: No.Hydromassage Bathtubs No.of Motors Total HP No.of Devices or Equivalent OTHER: Attach additional detail if desired or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to Start:5-17-21 Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Coastal Light Electric Lic.NO.:20711-A Licensee: Alex Kuharenka Signature LIC.NO.: (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:508-274-9981 Address:46 Nickerson Farm Way, S. Yarmouth, MA 02664 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)0 owner ❑owner's agent. Owner/Agent I PERMIT FEE:$ I-Co o. Signature Telephone No. EMAIL: CONTACT@COASTALLIGHTELECTRIC.COM SOLAR PV SYSTEM+TESLA BATTERY ONE-LINE DIAGRAM ADDRESS:41 POWERS LANE,YARMOUTH, MA 120/240v OWNER: PROKOP UTILITY DATE: 12/22/2020 SERVICE 1 OF 3 EXISTING UNDERGROUND SERVICE TO BUILDING UTILITY METER METER 200AMP 2POLE00AM EXISTING MAIN BUILDING DISCONNECT 2POLE,120/240V,400 AMP 4/0 SER AL CABLE TESLA BACKUP GATEWAY 200 AMP MAX. 4/0 SER AL CABLE 2/O SER AL CABLE GENERATION PANEL BUSSBAR RATED 125AMPS EXISTING LOAD CENTER 1125AMP J 2POLE 200AMP 30AMP/2P 30AMP/2P 2POLE r- 1 r"'1 30AMP/2P 30AMP/2P .'h r^\t c-Th e-Th -1 TO SOLAR PV SYSTEM TO(3)FIVE TESLA POWERWALL2 BATTERIES 15 ENPHASE IQ 7+MIRCOINVERTERS MAX CONTINUOUS CURRENT:24A X 3=72A MAX CONTINUOUS CURRENT:18.13A (PAGE 2) PV SYSTEM OUTPUT PEAK: 4.43 KW AC PV SYSTEM OUTPUT CONTINUOUS: 4.35 KW AC 15 -QTY ENPHASE IQ7+ MICROINVERTERS 15 -QTY LG 360 WATTS PV PANELS SOLAR PV SYSTEM+TESLA BATTERY ONE-LINE SOLAR PV SYSTEM DIAGRAM ADDRESS:41 POWERS LANE,YARMOUTH, MA OWNER: PROKOP DATE: 12/22/2020 2 OF 3 3-#10AWG CU THHN+#10AWG GROUND EXTERIOR MAIN SOLAR PV SYSTEM DISCONNECT 120/240V,1PHASE,3WIRE, 30 AMP, J NEMA 3R,LOCKABLE, J VISIBLE BLADE SWITCHING ACTION ACCESSIBLE 24/7 UTILITY SMART METER METER 120/240V,1PHASE,3WIRE 3-#10AWG CU THHN+#10AWG GROUND INTERIOR COMBINER PANEL COMMUNICATION ENVOY 15AMP/2POLE 120/240V,1 PHASE,4 WIRE, UNIT r"1 REVERSE FEED RATED 20AMP/2POLE r-Th 20AMP/2POLE CIRCUIT CIRCUIT A B SYSTEM OUTPUT PEAK:10.915 KW AC SYSTEM OUTPUT CONTINUOUS:10.73 KW AC (37)QTY ENPHASE IQ7+ MICROINVERTERS (37)QTY LG 375 WATTS PV PANELS TYPICAL BRANCH CIRCUIT SOLAR PV SYSTEM+TESLA BATTERY ONE-LINE DIAGRAM • ADDRESS:41 POWERS LANE,YARMOUTH, MA OWNER:PROKOP DATE: 12/22/2020 3 OF 3 (2)#12 AWG THHW CU+(1)#12 AWG CU GROUND #8 BARE SOLAR PANEL #8 BARE SOLAR PANEL CU Cu ■■NNEN •••••• _ _ ■M1■N■ ■■■WEN ■■■■■■ ■■■■■■ E M■■■ ■■■■■■ ■■■■■■ ■WEN ■■■■■■ ■■■■■■ WEENIE ■■■■■■ ■■■■■■ ■■E■■■ ■■■■■■ ■■■NEN ■■■■■■ ■■■■■■ ■■■■M■ WEENIE WEENIE MICRO ENPHASE MICRO ENPHASE INVERTER i 1Q7+ INVERTER IQ7+ UP TO 13 MICRO-INVERTERS J-BOX ENPHASE AC INTERCONNECT CABLE-2 X#12 AWG