HomeMy WebLinkAboutEngineer PlanLEGEND EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99]-- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 TEST HOLE SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 3 BEDROOM DWELLING DESIGN FLOW: 3 BEDROOMS ® 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 2500 GAL.DUAL COMPARTMENT SEPTIC TANK/PUMP CHAMBER LEACHING: 330 GPD / (.74) = 446 SF REQUIRED 15' X 30' = 450 SF OK 450 SF X .74 = 333 GPD OK USE A 15' X 30' PIPE AND STONE LEACHING FIELD APPROVED DATE JABINETES /�/ 10.7 / / BEACH POND /// ARFfA / O LIVING ROOM PORCH KITCHEN DCE #22-348 C: 011 BATH �06P 19 0,3,4, z,� BATH LIVING ROOM 0 UNFINISHED FLOOR PLAN NOT TO SCALE SILT FENCE o WORK LIMIT LINE-� MA BOARD OF HEALTH 1$ PATIO *PLUMBING UNDER SLAB * 15.9't SYSTEM PROFILE MARK CORNERS OF NOTES (NOT TO SCALE) 2' CAST IRON COVERS TO GRADE LEACHING FIELD W/ REBAR SET 4" BELOW PROVIDE INSPECTION PORTS TO 1. DATUM IS NAVD 88 PROVIDE MIN. 20" DIAM. WATERTIGHT GRADE WITHIN 3" OF FINISH GRADE 2. MUNICIPAL WATER IS EXISTING ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2111 SLOPE FILTER FABRIC 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 18.0' MINIMUM .75' OF COVER OVER PRECAST 2% SLOPE REQUIRED OVER SYSTEM 20.0 TOP 17.02' FINISHED GRADE- 4' LOAM do SEED OR PAVE AS REQ. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS NOTE: 2" MIN. WALL Jill TO BE AASHO H-2,Q PROP. TEE THICKNESS REQUIRED 4"s�SCH40 PVC CLEAN FILL 5. PIPE JOINTS TO BE MADE WATERTIGHT. PIPES LEVEL 1ST 2' r POMRAIED PVC 5' C. S=0.005 ° _ 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 2500 GAL H-20 ° 310 CMR 15.000 (TITLE 5.) » 3/4 1-1/2" DOUBLE WASHED 10 SEPTIC TANK/ 8" STTONE LEACHING FIELD ° 6-DEPTH MIN BELOW INV. 15.0, TEE PUMP CHAMBER ° 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO COMBINATION o0.0 oo,00Qao,o 16.67 LEVEL BOTTOM a 16.5 BE USED FOR LOT LINE STAKING OR ANY OTHER SEE DETAIL BELOW .00 ��0` 0?00 ,� PURPOSE. 16.94' 1 .77' 30.0' 8. PIPE FOR SEPTIC SYSTEM TO SCH. 401 PVC. 16 moo,00a,000,o,o,00000'�����'�'�����'�'00.00 � 9. COMPONENTS NOT TO BE BACKFlLLED OR CONCEALED o,o-0 3?"pC�C�G�C�COG�G�G�CpG�G�GG�C�C�p�C��� 1 WITHOUT INSPECTION BY BOARD OF HEALTH AND 7,o.,ono _ f._tf_.1_'�.7 0 0 0 0 0 1^.P_�_�_'i.7.o o (� NX SLOPE) ( X SLOPE) (2 X SLOPE) 5.3' 6" CRUSHED STONE OR MECHANICAL PERMISSION OBTAINED FROM BOARD OF HEALTH. COMPACTION. (15.221 (21) 1 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CAWNG WATER -TEST D'BOX FOR LEVELNESS FOUNDATION 35' SEPTIC TANK/ 8' D' BOX 7' LEACHING PUMP CHAMBER FACILITY *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM o� BENCHMARK: CATCH BASIN = 16.9' NAVD88 �VED DRIVEWA s O• LOT AREA \ I 40,300 S.F.f \ UPLAND -241 N6�-t11 20 ACCESS FOR ROUTINE MAINTENANCE MUST BE PROVIDED FOR ZABEL FILTER. INSTALLER MUST FOLLOW ALL MANUFACTURER'S SPECIFICATIONS FOR PROPER FILTER INSTALLATION ALARM AND CONTROL PANEL ---� TO BE INSTALLED INSIDE BUILDING. ALARM TO BE ON INV. IN 15.0' SEPARATE CIRCUIT FROM PUMP ZABEL FILTER - FLOAT SWITCH ALARM ON (A1800) OUTLET TEE W/EXTEN SETTINGS: PUMP ON 3j 5" WORKING RANGE 6» 5" PUMP OFF 12" WE 0 POND ELEV. 10.7 DIGSAFE 1 888 344-7233AN nossett Pond Horse o N Pond LOCATION( OF ALL UNDERGROUND & OVERHEAD UTILITIES LOCUS MAP PRIOR TO COMMENCEMENT OF WORK. SCALE 1 "=2000'f 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. ASSESSORS MAP 47 PARCEL 5 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. ACCESS FOR ROUTINE MAINTENANCE MUST BE PROVIDED FOR ZABEL FILTER. INSTALLER MUST FOLLOW 24"0 CAST IRON MANUFACTURER'S SPECIFICATIONS FOR PROPER FILTER COVERS TO GRADE INSTALLATION. 567 GAL. RESERVE 14. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM IS PROVIDE QUICK DISCONNECT FOR PUMP SUITABLE FOR PUMP CONNECTION. ELECTRICAL PERMIT AND BALL VALVE REQUIRED. 15. WETLAND FLAGGED BY PAUL SHEA OF INDEPENDENT ENVIRONMENTAL CONSULTANTS, INC. 2500 GAL. SEPTIC TANK/ s" BAFFLE PUMP CHAMBER COMBINATION (NOT TO SCALE) NO LOW POINTS -0.25" WEEP HOLES CHECK VALVE MYERS SRM 4 SUBMERSIBLE 4/10 HP PUMP GI7�1oV APR 2 6 2023 HEALTH DEPT, TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE # 13871 WITNESS: JAY GARDINER DATE: 11/17/2022 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 1 0" 20' A LS 10YR 3/2 8" B LS 18" 10YR 5/8 18 5' PERC C MS 10YR 7/6 126" �9.5' NO GROUNDWATER ENCOUNTERED TITLE 5 SITE PLAN OF #63 PARTRIDGE VALLEY ROAD WEST YARMOUTH, MA PREPARED FOR STEPHEN ROSALES DATE: NOVEMBER 21, 2022 Yarmouth Health Department Scale:1 "= 20' APPROVED iiiiii DANIEL cyG� �s' s'�y 0 10 20 30 40 50 FEET ` A. a �� DANIELA. -� ame Date OJALA o OJALA a, No 40980 " CIVIL 9 a� Pow �Fc� Nooff 508-362-4541 .46502 fax 508-362-9880 �sUR�� �Ssi0N L ENdowncope.com down cope ea8inee�iof, inc. civil engineers land surveyors 939 Main Street ( R to 6A) DATE DANIEL A. OJALA, P.E., P.L.S. YARMOUTHPORT MA 02675 22-348 1